| 1 | EARTH WORK EXACAVATION |
| 2 | Excavation in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50 M lead upto 30 M and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in-charge upto a distance of 30 M from the foundation trenches. (S.I. No. 251a) /2022 |
| 3 | Sand filling in plinth and under floor including supply of necessary quantity of sand from a distance not exceeding 8 Kms. from the site of work and including watering, dressing etc. labour and T&P etc. required for proper complition of the work, saplings of girth upto 30 cms. measured at height of 1 M. above ground level and removal of rubbish upto a distance of 50 M. out side the periphery of area cleared, including cost of sane.(S.I.NO.255/2022) |
| 4 | CEMENT CONCRETE WORKS |
| 5 | Concrete with 4cm. gauge brick ballast, coarse sand of 2.20 F.M and cement in proportion of 8:4:1 in foundation and under floors, including supply of all materials, labour, T&P etc. required for proper completion of the work.(SI.No.279/2022) |
| 6 | (a) Sanse as above item no.279 but with 2cm.gaug stone grit instead of 4 cm. gauge |
| 7 | (b)Same as itern no.279(a)but in proportion of 1:3:5 |
| 8 | As in item 279 above but in proportions of 8:4:1 stone Ballast Coarse sand and cement. |
| 9 | R.C.C. work with cement approved corsand & 2 cm gauge stone grit in proportion of 1:2:4 in lintels of door & windowsExcluding supply of reinforcement and its bending, but including its fixing and binding the same waith 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, Tools & plants etc. required for proper completion of the work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. (S.I. No. 283/2022) |
| 10 | As in itom 283 above but for slabs. |
| 11 | As in item 284 above but for slabs in 1:1.5:3. |
| 12 | RCC work with cement, approved Coarse sand and 40mm stone grit in proportion of 1:1.5:3 in raft and foundation excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire. (S.I. No. 287a/2022) |
| 13 | As in item 283 above but in R.C.C. in 1:1.5:3 (column & T-Beam) |
| 14 | REINFORCEMONT STEEL |
| 15 | M.S (Tor steel or plain) work in plain work such as RCC or RB work including bending for proper shape and including supply of steel and its wastage, bend, hooks and authorized over lapping shall be measured and including cost of binding wire (S.I. No. 504/2022) A.R. |
| 16 | Brick Work Masonry |
| 17 | M-150 brick work in 1:4 cement and coarse sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all material, labour T&P etc. required for proper completion of the work as per direction of the work as per direction of Engineer-in-charge. |
| 18 | (Extra for Superstructure) As in item 302(B)to 307 Jabove but in superstructure including necessary Cutting & moulding of tricks as required thi kness of walls not to be less than 1Mbrick. Add ext labour to above items.(305a+310) |
| 19 | PLASTERING WORK |
| 20 | 12mm thick plaster with cement and fine sand af 1.25 fineness modules in 1:3 over brick work minimum thickness not to be less than 1cm.includings up ply of all materials, labour, tools&plant setc. Required for proper completion of the work.(S.I.NO.582/2022) |
| 21 | As in item(582)above but with cement and fine 586 sand of 1.25 fineness modules mortar in 1:6(S.I.NO.584/2022) |
| 22 | 20 mm thick rough cast exterior cement plaster on wall consisting 10 mm thick backing cast of 1:3 cement mortar (1 cement :3 coarsesand) and 10 mm thick finishing coat of 1:3 cement mortar(1cernent:3coarse aggregate of size 6mmto12mm)including arises, chamfersand/or rounded angles not exceeding 80 mm.(S.I.NO.New Item Ch-13/2022) |
| 23 | FLOORING WORK |
| 24 | Supply and fixing of Kota stone in flooring 20mm thick and joint filled with 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12 mm base coat (bedding)of 1:2 cement & come sand morter and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, Tools & plants etc.required for proper completion of the work.(S.I.NO.New Item Ch-14/2022) |
| 25 | MS FABRICATION WORKS |
| 26 | StaircaseProviding, Fabricating, erecting and installing in position MS staircase using any type of regular sections, hollow & casted, as per the drawings comprising of MS balustrades, nunners, hollow pipes, ISMB, ISMC etc. including cutting, drilling. Welding, grinding and other operations as required to give a smooth finish, fixing all accessories, providing pockets in RCC/brickwork, drilling holes in stone etc as required and grouting the with ironist mix including necessary shoes/caps etc. including one coat primer & two coat of synthetic enamel paint etc. complete. (S.I.NO.502(A)/2022) |
| 27 | Supplying and fixing rolling SHUTTERS of approved make made 80x125mm (3\"x5\") cold rolied M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs.(S.I.NO.520/2022) |
| 28 | Providing and fixing 27.5cm long wire spring grade2 for rolling shutters.(S.I.No.521/2022) |
| 29 | providing and fixing top cover for miling shutters 2.50 meter wide.(SI.No.522/2022) |
| 30 | Providing and fixing ball bearing for rolling shutters. |
| 31 | RailingProviding, Fabricating, erecting and installing in position MS railing using any type of regular sections, hollow & casted, as per the drawings comprising of MS balustrades, nunners, hollow pipes, ISMB, ISMC etc. including cutting, drilling. Welding, grinding and other operations as required to give a smooth finish, fixing all accessories, providing pockets in RCC/brickwork, drilling holes in stone etc as required and grouting the with ironist mix including necessary shoes/caps etc. including one coat primer & two coat of synthetic enamel paint etc. complete. (S.I.NO.502(A)/2022) |
| 32 | Providing and fixing 1mm thich M.S. Sheet door/window with frame of 40x40x6mm (11/2\"x11/2\"x1/4\") angle iron 3.15 mm (1/8\") thick M.S. gus set plate at the junction and corners including supply and fixing of necessary fittings. Lock rail of 15\" length of oxidised iron and including pintel hoks at the top and applying priming coat of red lead paint on all sets complete.(SI.No.517a/2022) |
| 33 | PAINT WORKS |
| 34 | Distempering (firstcoat)with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N,Shalimar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also including the surface even with plaster of Paris or approved synthetic materials and sand papered smooth including supply of all materials, labour, Tools&plants etc.required for proper completion of the work.(SI.No.649/2022) |
| 35 | As in item(649) above but for every coat after the first coat.(SI.No.650/2022) |
| 36 | Finishing wall with two coat of paint. (SI.No.15.22 New item /2022) |
| 37 | MECHANICAL |
| 38 | Preliminary Works |
| 39 | Shop Drawings |
| 40 | Detailed flow diagram, equipment list, power load requirment |
| 41 | Design, calculations of all slements of ine prant, electrical and mechanical work to satisly adequacy of design |
| 42 | Submission of detailed GA FOR CONSTRUCTION electiel, mechanical and piping drawing for approval. |
| 43 | SEWAGE TREATMENT PLANT |
| 44 | Design, Supplying, Installing, Testing & Commissioning of Sewage Treatment Piant capacity 200 KLO. The plant proposed shall be 90 kid with a common penp roem. The plant is proposed to be installed is tim besoment accessible frans to pump room itself for future maintenance. No opening shall be jorgvisted on mala sieb above for this aucrose, for the following. |
| 45 | Neture of effluent Domestic Sewage from Tollot use and kitchen waste. |
| 46 | Daily average flow-200 Cum/Day |
| 47 | PH-5.0-9.0 |
| 48 | BOD5-up to 250-250 Mg/t |
| 49 | Solids 400-700 Mg/L |
| 50 | COD-upto 600-850 mg/L |
| 51 | Oil & Grease-S0 Mg/L |
| 52 | Nitrogen Tota! - Standard |
| 53 | Fecal Coliform MPN/100 ml:- Standard |
| 54 | Effluent discharge standard after treatment: |
| 55 | pH-5.5-9 |
| 56 | BOD5-30 Mg/L |
| 57 | S. Solids - <20 Mg/L |
| 58 | COD-70 Mg/L |
| 59 | Oil & Grease-<5 Mg/L |
| 60 | Nitrogen, Total < 10 mg/ltr |
| 61 | Fecal Coliform MPN/100 ml:- Desirable-100, Permissible-230 |
| 62 | Sewage treatment plant shall include the following items: |
| 63 | Bar Screen Chamber |
| 64 | Oil & Grease Chamber |
| 65 | Sewage equalization tank/sump |
| 66 | MBBR Tank-2 nas |
| 67 | Secondary Settling tank-1 no |
| 68 | Clear Water tank |
| 69 | Treated Water tank |
| 70 | Sludge Holding Tank |
| 71 | Ultra Filtration Tank |
| 72 | Filtration through DMF & ACF |
| 73 | Filtration through Ultra Filteration Plant |
| 74 | Air Blowers, Pumps & equipment |
| 75 | Piping, valves etc |
| 76 | Electrical Panel & Cabling |
| 77 | Common plant room adjacent to STP. |
| 78 | All piping, valves & level Indicator/controller etc. within plant room. |
| 79 | Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & diagram, schematic diagram for the above mentioned components and additional components such as Inserts, puddle flanges, vent pipes etc. If so required for the complete work. |
| 80 | Supply, Installation, Testing & commissioning of MS dip hot galvanised puddle flange. |
| 81 | 65mm dia & 750 mm Length MSG puddle |
| 82 | 80 mm dia & 750 mm Length MSG puddle |
| 83 | 100 mm dia & 750 mm Length MSG puddle |
| 84 | Supply, Installation, testing & commissioning of 2 Nos(1w+1s) Stainless Steel Perforated Screen with sultable lifting arrangement (size 500 mm wide x 600 mm high approx) |
| 85 | Indus Eco/Fabricated |
| 86 | Supply, Installation, testing & commissioning of electronic type level Indicator and controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts. |
| 87 | STP Pumps |
| 88 | Raw Sewage Lifting Pumps |
| 89 | Providing and fixing compact munoblock or mathi ruzable rating, with non-clog free flow open Impeler, 415 Volts ± 10%, 3 Phase, 50Hz, AC supply, spiled thamber, guide wire for lifling & lowering pune duck foot bend complete. The pump sats saali be accessories & as cer specification with the following obmersible pumps of able for operatlen on 130 RPS, including oil ratanized lifting chain, pplied with required accessries & as per specification with the following. |
| 90 | Pump Headers and other interconnecting to be CI LA class or GI |
| 91 | Complete Inlet, outlet and header piping of suitable discully shall not excand 1.5m/s)-1 Lot |
| 92 | Butterfly valve and Dual Plate NRV of appropriate dio zad rating-1 Lat |
| 93 | Necessary cables from pump sets to pump starter pan Lot |
| 94 | Electrical control panel having all necessary accessories & safeby devices of standard specifications and suitable for receiving Inconer cable to connect complete. (Panel for sump pumps near sach summer site conditions). - 1 No |
| 95 | Discharge: 10 m3/Hr |
| 96 | Head: 10-15 m |
| 97 | Solid Handling: 12 mra |
| 98 | Motor Efficiency Class-EFF1 |
| 99 | Note: |
| 100 | Pumps shall be operated on cyclic timing |
| 101 | The entire system along with pumps & control panel must be sourced from sinele manufacturer only for unit responsibility. |
| 102 | One Jet consist of 2 nos, of pumps-1 working & stand by (Complete set as above to, pumps including cost inr valves, plpine, Control Panel, Cabling, contactors, breakers, overload relay, Level Contullers, float switch, level indicators, pressure gauites etc es required and as specified) |
| 103 | Make-Kirlosen/ wilo \"xylem/Shakti |
| 104 | Sludge Transfer/Recirculation Pump |
| 105 | Providing and fixing centrifugal Sludge Return / Ra circulation pumps for the transfer of sludge from tube settler with Cast Iron Impeller and cast steel shaft with mechanical seal, with TEFC Induction motor of class \"F\" Inculation & efficiency class EFF-1, suitable for operation on 415 volts ±10%, 3 phase, 50 Hz, A.C. supply, 2900 RPM complete in all respects and sper specification with the followine capacities: |
| 106 | Pump Headers and other interconnecting to be CILA Class or Gl |
| 107 | Complete inlet, outlet and header piping of suitable dia (velocity shall not exceed 1.5m/s)-1 Lot |
| 108 | Butterfly valve and Dual Plate NRV of appropriate dia and rating-1 Lot |
| 109 | One set includes 2 nos, of pumps-1 working + 1 standby |
| 110 | Discharge: 10 m3/Hr |
| 111 | Head: 10-12 m |
| 112 | Solid Handling: 7 mm |
| 113 | Motor Efficiency Class-EFF1 |
| 114 | The cement concrete foundation shall be 200 mm high and 150 mm projection on all sides ofM.S. base frame shall be designed by the STP contractor and exeuted by the main civil contractor. |
| 115 | Air diffusion systein |
| 116 | Providing and fixing Air Blowers of twin-lobe type (air cooled) for continuous service with construction in cast iron casing, for oll-free air delivery with anti-friction bearings alloy steel toughended shafts, duly coupled with suitable drive for operation on 415 volts ±10%, 3 phase, 50 Hz, A.C. supply complete with testing and commissioning etc.as specified and as required with the following detalls |
| 117 | No. of air blowers: 2 (1W+15) |
| 118 | Air Capacity: 340 m3/Hr |
| 119 | Static Head: 0.45 kg/cm2 |
| 120 | Note: |
| 121 | The cement concrete foundation shall be 200 mm high and 150 mm projection on all sides of M.S. base frame shall be designed by the STP Contractor and executed by the Main Civil Contractor. |
| 122 | Make-Akash/TMVT/Everest |
| 123 | Non clog type air dispersion system capable of handling 3-5 cfm of a\"r with oxygen transfer efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced/repalred |
| 124 | Fine bubble diffusers (Capacity 5-6 m3/hr) |
| 125 | For equalization tank& SHT-1 No. |
| 126 | MBBR reactor tank-2 Nos. |
| 127 | Make:- Bharat/IET/Southern Coagen/Rehau |
| 128 | Note: |
| 129 | Alr dispersion system shall be provided for Equalisation Tank, Sludge holding Tank and MBBR Tank. |
| 130 | Providing and fixing all piping (as described below) and Isulation control valves for making the system complete. |
| 131 | Upvc: Submerged air piping, overflow & Plant Interconnecting piping |
| 132 | MS Epoxy: Air piping Non submerged |
| 133 | Piping make:- Prince/astral/Supreme/Ajay pipes, MSdal Hiser/Star B class Valves make Zoloto/Sant/Advance/Audco Astaz/Prince/Supreme/Ajay |
| 134 | BFV 50 MM |
| 135 | BFV 65 MM |
| 136 | BFV 80 MM |
| 137 | BFV 100 MM |
| 138 | NRV 50 MM |
| 139 | NRV 65 MM |
| 140 | NRV 80 MM |
| 141 | NRV 100 MM |
| 142 | MS pipe 50 MM |
| 143 | MS pipe 65 MM |
| 144 | MS pipe 100 MM |
| 145 | upvc pipe 40 mm |
| 146 | upvc pipe 50 mm |
| 147 | upvc pipe 65 mm |
| 148 | upvc pipe 0 mm |
| 149 | Supply, Installation, testing and commissioning of PVC MBBR medis to be Installed in MBBR Tanks (2Nos.) and PVC tube deck settling madle to be installed In Secondary Settling Tank alongwith suitable slucige removal arrangement either by pumps or air lifting gumas... |
| 150 | Vendor to specify Surface area and flow rate |
| 151 | MBBR Tank-2 nos., STS tank- 1no. |
| 152 | STS Tank 1 Nos. Make: MM aqua |
| 153 | Filter Feed Pump |
| 154 | Providing and fixing In-line horizontal multistage centrifugal clear water pump set with Cl casing & Impeller, Carbon Steel shaft Cl base with CED coating, complete directly coupled with TEFC Induction mater of class \"F\" Insulation & efficiency class EFF-1, 2900 RPM, suitable for operation on 415 volts ±10%, 3 phase, 50 Hz, A.C. supply (with cartridge type mechanical seal), pressure gauges with gunmetal isolation cocks, vibration elimination pads, etc. mounted on a MS base frame bolted to cement concrete foundation complete in all respects and as per specification with following capacities. |
| 155 | Make - Kirlosakr/wilo/xylem/Shakti |
| 156 | Complete inlet, outlet and header piping of sultable din (velocity shall not exceed 1.5m/s)-1 Lot |
| 157 | Butterfly valve and Dual Plate NRV of appropriate dia and rating - 1 Lot |
| 158 | Discharge: 10 m3/Hr |
| 159 | Head: 30-35 m |
| 160 | No. of Pumps: 2 (1W+1S) |
| 161 | Note: |
| 162 | Operation of pump shall be based on level controller proposed to be installed in tank as per site location. |
| 163 | The cement concrete foundation shall be 200 mm high and 150 mm projection on all sides of M.S. base frame shall be designed by the STP Contractor and Nos. executed by the Main Civil Contractor. |
| 164 | Make-Kirlosakr/wilo/xylam/Shakti |
| 165 | Treated water Pump |
| 166 | Providing and tising in-line tamage contriga clear water pump set with Cl casing & Impeller, Carbon Steel shaft, Ci base with CED coating. complete directly coupled with TEFC Induction motor of class \"F\" Insulation & efficiency class EFF-1, 2900 RPM, suitable for operation on 415 volts ±10%, 3 phase, 50 Hz, AC. supply (with cartridge type mechanical seal), pressure gauges with gunmetal isolation cocks, vibration allmination pads, etc, mounted on a MS base frame bolted to cement concrete foundation complete in all respects and as per specification with following capacities. |
| 167 | Complete inlet, outlet and header piping of sultable dla (velocity shall not exceed 1.5m/s)-1 Lot |
| 168 | Butterfly valve and Dual Plate NRV of appropriate dia and rating-1 Lot |
| 169 | Discharge: 20 m3/Hr |
| 170 | Head: 20 m |
| 171 | No. of Pumps: 2 (1W+15) |
| 172 | Note: |
| 173 | Operation of pump shall be based on level controller proposed to be installed in tank as per site location. |
| 174 | Make Kiriosakr/wilo/xylem/Shakti |
| 175 | Providing, Installing, testing and commissioning vertical down flow type multi grade sand bed pressure filter capable of filtering 10 cum./hour of effluent at prescribed filtration rate of 16 cum/sq.m/hr. The filter shall comprise of MSEP MOC suitable for a minimum operating pressure of 3 kg/sq.cm., complete with pedestal, access cover, PVC underbed, 50 mm dia frontal piping with valves, pressure aunge, first charge of filter media, etc. |
| 176 | Dual Media Filter (900 DIA x 1800 Ht |
| 177 | Filteration Rate-16000 L/Sq.M/Hr |
| 178 | Working Pressure-2.5-3 Kg/cm2 |
| 179 | Capacity-10 m3/Hr |
| 180 | Make Thermax/lon Exchange/Indus Eco |
| 181 | Activated Carbon Filter (900 DIA x 1800 Ht) |
| 182 | Filteration Rate-16000 L/Sq.M/Hr |
| 183 | Working Pressure-2.5-3 Kg/cm2 |
| 184 | Capacity-10 m3/Hr |
| 185 | Make Thermax/lon Exchange/Indus Eco |
| 186 | Providing and fixing chemical dosing system with all accessories, suitable to doze chemical soluktion upto 1 ppm doze (of Sodium Hypo-chloride solution) to a filtered water flow of 50,000 lph, against a pressure of 1.5 kg/cm2 complete with FRP moulded solution holding tank of min. 100 litre with all standard accessories & structural arrangement Including suitable foundation bolts & other accessories.etc.complete as required and as specified. |
| 187 | System: Metering Type |
| 188 | Capacity: 0-6 LPH |
| 189 | Feed Solution: Hypochlorite |
| 190 | Conc. Of Solution: 0.1 |
| 191 | MOC and Capacity of Tank: HDPE-200 Litres |
| 192 | Make: Intitiave/Edose/UKL |
| 193 | Providing, fixing and testing Electro megentic Water Flow Meters in C.1./brass body flanged at both ends with companion flanges, gaskets, bolts nuts and washers, with electronic digital type display for real time & totalized flow rate of water, with panel and cabinet, memory facility, flow switches and sensors and required accessories complete including cutting and making good the pipeline, and making all electrical connections. Water meters should be BMS compatible Testing to be carried out at 200 lbs/psi with cold water for consistent quality.(with bypass arrangements with 3 valves) |
| 194 | Make: UPC/Aster/Flowstar |
| 195 | Providing, Fixing, Testing & commissioning of Basket Type Centrifuge of 500 mm dia, bowl inSS 304 complete with all required spares & fittings, dosing system, electric motor of suitable KW & RPM suitable for 415 (+/-), 10% 50 Hz operation complete in all respect. |
| 196 | Make Apollo/ AB Engineers/IETAN |
| 197 | Non clog type horizontal centrifugal Centrifuge Feed Pumps capable of Handling solids upto 8 mm having C.I. Casing, C.I. Impeller, SS Shaft, Chrome steel shaft sleeve, IP 44 Class B insulation, mechanical seal complete with all accessories, motor of required capacity, pressure guage on delivery line with isolation valve No etc complete in all respect. qty: 2 nos( 1W+1 S). Flow-2 m3/hr, Head-30 to 40 meter |
| 198 | Pumps Make: Kirlosakr/wilo/xylem/Shakti |
| 199 | ELECTRICAL INSTALLATION FOR STP |
| 200 | Electrical Panel-Motor Control Centre |
| 201 | Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of non-compartmental type motor con vol centre fabricated out of 14/16 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coate of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. |
| 202 | Motor Control Centre |
| 203 | Incoming |
| 204 | 1 no. of suitable rating of........MCCB with the following accessories: |
| 205 | One (1) No. digital type VAF Meter & energy méter (schneider or equivalent) with one set of CTS of ratio 100/5A |
| 206 | Description |
| 207 | One (1) set of R, Y, B phase indication lamps and ON/OFF/Trip indication Lamps with control SPMCB. |
| 208 | Bus Bar |
| 209 | Suitable amp TPN Aluminium bus bar with heat shrinkable insulation sleeves. |
| 210 | Outgoing |
| 211 | 2 Nos. 22 kw DOL Starters, for Raw Sewage Transfer Pump, complete with suitable range of TP MCB Contactor & required no. of indicating light, push botton & auto/man selector switch etc. |
| 212 | 2 Nos. 2.2 kw DOL Starters, for Filter Feed Pump, complete with suitable range of TP MCB Contactor & required no. of Indicating light, push botton & auto/man selector switch etc. |
| 213 | 2 Nos. 0.75 kw DOL Starters, for Sludge Transfer Pump, complete with suitable range of TP MCB Contactor & required no. of Indicating light, push botton & auto/man selector switch etc. |
| 214 | 2 Nos. 0.75 kw DOL Starters, for Sludge Recirculation Pump, complete with suitable range of TP MCB Contactor & required no. of indicating light, push botton & auto/man selector switch etc. |
| 215 | 2 Nos. 5.5 kw DOL Starters, for Air Blower, complete with suitable range of TP MCB Contactor & required no. of indicating light, push botton & auto/man selector switch, cyclic timer etc. |
| 216 | 1 Nos. 0.75 kw DOL Starters, for submersible mixer, complete with suitable range of TP MCB, Contactor & required no. of indicating light, push botton & auto/man selector switch etc. |
| 217 | 2 Nos. 0.75 kw DOL Starters, for centrifuge feed pump, complete with suitable range of TP MCB Contactor & required no. of indicating light, push botton & auto/man selector switch etc. |
| 218 | 1 Nos. 0.75 kw DOL Starters, for centrifuge, complete with suitable range of TP MCB Contactor & required no. of Indicating light, push botton & auto/man selector switch etc, |
| 219 | 1 Nos. 2.2 kw DOL Starters, for spare, complete with suitable range of TP MCB Contactor & required no, of Indicating light, push botton & auto/man selector switch etc. |
| 220 | 1 Nos. of suitable rating of PP MCB for connection of UF system, |
| 221 | 1 Nos. of suitable rating of DP MCB for connection of UV system. |
| 222 | 2 Nos. of suitable rating of DP MCB with selector switch for the connection of 40w dosing system. |
| 223 | SPARE MCB |
| 224 | 12 Nos. 16Α ΤΡN MCB |
| 225 | 12 Νο8. 32Α ΤΡΝ MCB |
| 226 | 1 Nos. 16A DP MCB |
| 227 | a) All MCCB\"s/MCB\"s shall be suitable for motor duty application. |
| 228 | b) all MCB shall be use C-curve. |
| 229 | b) All motor starters shall be provided with Auotmatic level controller whereever required. |
| 230 | c) DOL starters shall be used for moters up to 10 HP and above Star-Delta Starters for other motors. |
| 231 | d) Provision shall be made for providing potential free contacts of ON status to all pumps starters |
| 232 | MCC Panel as described above |
| 233 | Make :-Advance/Batra/Indus Eco |
| 234 | Supplying & laying of following sizes XLPE insulate & PVC sheated Copper conductor armoured cable of 1.1kv graderining to IS relevent IS etc as read |
| 235 | 3x2.5 sqmm.cu |
| 236 | 3x4 sqmm.cu |
| 237 | 4x4 sqmm.cu |
| 238 | 4x6 sqmm.cu |
| 239 | 3.5x50 sqmm.AI (LT cable) |
| 240 | 3.5x35 sqmm.AI (LT cable) |
| 241 | Supplying & laying of following sizes of Flexible & PVC sheated copper conductor armoured cable of 1.1Kv grade confirmning IS relevent IS etc as read read. |
| 242 | 3x1.5 sqmm.cu |
| 243 | Make: KEI/Polycab/RR |
| 244 | Supplying and making end termination with brass pression gland and copper/ aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor/copper cable ot 1.1 KV grade as required. |
| 245 | 3x2.5 sqmm. |
| 246 | 3x4 sqmm. |
| 247 | 4x6 sqmm. |
| 248 | 3.5x35 sqmm. |
| 249 | 3.5x50 sqmm. |
| 250 | Supplying and installing following size of perforated Het Diapert Galvanised Iron cable tray with e ceiling with G.I. suspenders including a bels & nuts, etc. as required. Make - Supersteel/Slotco |
| 251 | 75 mm width X 40 mm depth X 1.6 min thickness |
| 252 | 150 mm width X 40 mm depth X 1.8 mm thickness |
| 253 | 300 mm width X 40 mm depth X 1.6 mm thickne |
| 254 | supply & fixing of folowing type of Gl strip/wire incar ng all necessories like Gl, nut, bolt, washer etc, as required. |
| 255 | 25x3 mm GI strip |
| 256 | 6 mm cu wire |
| 257 | Supply with installation of earthing pit with copper bon led earthing rod of 3 mtr. leangth included 25 kg backfill compound with required acessories like pit cover copper nut bolt etc. |
| 258 | Supply with installation of 6 meter height hot dip galvarnsed octagonal street light poles including 45W LED light with required anesories like single erm nut, bolt, foundation bolt etc. Make - Bajaj/crompton |
| 259 | change over switch of required capacity for termination of main supply after transformer before feeding to MCC panel make- L&T/VCH. |