}

Tender For C/O Green House Under Project Gap-352, palampur-Himachal Pradesh

Council Of Scientific And Industrial Research has published Tender For C/O Green House Under Project Gap-352. Submission Date for this Tender is 14-10-2025. Electrification Work Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51369460
Tender For C/O Green House Under Project Gap-352
Tender
Indian
Himachal Pradesh
Palampur
14-10-2025

Tender Details

Tender For C/O Green House Under Project Gap-352; 1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil 2 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.: All kinds of soil. 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 5 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.: Electric resistance or induction butt welded tubes 6 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 7 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 8 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement : 6 fine sand) 9 Providing and fixing tripple wall Polycarbonate sheet, 10 mm thick, multi UV protected, of make LEXAN/MACROLON or equivalent, in roof upto any pitch, including fixing.The sheet shall be fixed using self drilling/self tepping screws with EPDM seal including Aluminium profiles and EDPM gaskets on joints.The cost of Aluminium profiles shall be paid separately.Aluminium tape on free ends of sheet to be applied to prevent ingress of moisture in sheet.All joints to be sealed with Silicon of approved quality. 10 Providing and fixing double wall Polycarbonate sheet, 8 mm thick, multi UV protected, of make LEXAN/MACROLON or equivalent, in roof upto any pitch, including fixing.The sheet shall be fixed using self drilling/self tepping screws with EPDM seal including Aluminium profiles and EDPM gaskets on joints.The cost of Aluminium profiles shall be paid separately.Aluminium tape on free ends of sheet to be applied to prevent ingress of moisture in sheet.All joints to be sealed with Silicon of approved quality. 11 P/f cellulose pad (Cell dex) 4 thick (imported) for cooling system 12 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.: Internal work - Exposed on wall:20 mm dia nominal bore 13 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.: Circular tank 14 Providing and fixing G.I. Sheet frame for cellulose pads in U shape using 16 guage G.I. Sheet complete in all respects including moulding to required size and shape 15 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm 16 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore 17 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 18 Providing Aluminium profiles/moulding in required sections for roofing work.The wt. Of actual section fixed shall be taken for payment. 19 supplying & fixing single phase, 230 volts, 50 hz, self priming monoblock pump of rating 1.10 KW/ 1.5 HP, size 25 mmX25mm, duty SI, total head 50 mtr. (Make: Crompton/ Kriloskar) 20 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). Powdercoated die cast/ Extrudedaluminium Body (Thickness≥ 1.20 mm) a)18-22watt 21 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit with modular switch, modular plate, suitable GI/ PVC Box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make: Anchor/ Havells/ KEI/ Finolex). (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro: North West) i)Group C 22 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed ISI medium class PVC conduit as required. (Wire Make: Anchor/ Havells/ KEI/ Finolex).i) 2x4 sqmm + 1x4 sqmm earth wire 23 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed ISI medium class PVC conduit as required. (Wire Make: Anchor/ Havells/ KEI/ Finolex). i) 4x4 sqmm +2x4 sqmm earth wire 24 Supplying & fixing suitable size GI/ PVC box with modular plate and cover infront onsurface or in recessincluding providing and fixing 25 A modular socket outlet and 25 A modular SPMCB, C curve including connection, painting etc.as required.(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro: North West) 25 Providing & fixing following rating & breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connection, etc. as required. ( MCCB Make: Havells/ L&T/ C&S/ Standard).Note: MCCB supplied must be compatible to TPN DB)i) 100 Amp., 16 KA, TPMCCB 26 Supplying & fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB ,with provision of 100 amps TP 16 KA MCCB as incomer (but without MCB and incomer) as required.( TPN DB Make: Havells/ L&T/ C&S/ Standard). i) 8 way (4+ 24), Double Door 27 Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) Single Pole 28 Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.i) Tripple Pole 29 Supplying andfixing TP sheet steel enclosure on surface/recess along with 16/25/32 AC curve TP MCB complete with connections, testing commisioning etc. as required. 30 Earthing with GI Earth plate 600 mm x 600 mm x6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 31 Supply and laying 25mmx5mm G.I strip at 0.50 meter below ground as strip earth electrodes includingconnection of terminating with GI nut bolt,spring washers etc. as required(Jointing shall be done by overrlapping and with 2sets of GI nut bolts and spring washer spaced at 50mm) 32 Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i)Above 35 sqmm. And upto 95Sq.mm 33 Layingand fixing of one no. PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall or surface as required. i) above 35 sqmm and upto 95 sqmm(clamped with 1mm thick saddle) 34 Supplying & making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3.5 x 50sqmm(45mm) 35 Supplying & laying of following size DWC HDPE Pipe (ISI marked) along with all accessories like socket, bend, coupler etc. confirming to IS 14930, Part 2 complete with fitting and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation & refiiling the trench but excluding sand cushioning and protective covering etc complete as required.i)63 mm Dia (OD- 63 mm & ID-51 mm nominal). 36 Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ KEI/ Havells/ Finolex) i)3.5 core 50 sqmm

Key Value

Document Fees
INR 500 /-
Tender Value
INR 14.97 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail