Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-10-2025 |
| 2 | 29-09-2025 | CORRIGENDUM | BOQ | 23-10-2025 |
| Sl. No. | Item Description |
| 1 | M&L for monthly Inspection, maintenance and serviceing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed.Monthly Service : A Check :(a) Checking engine oil level and topping up as and when required . Note : Oil shall be measures and paid separately. (b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately. (c) Checking of oil bath air cleaner level. (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element (g) Checking engine alternator coupling, mounting bolts and alignment (h) Tighting all nuts, bolts, in altenator terminal block (j) Checking of alternator carbon brush and connections in alternator (k) Checking and tighting of all connection in DC control wiring. (l) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately (m) Checking and recording oil pressure, water and oil temperarute (n) Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately (o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level (q) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. (r) Checking of AMF panel, all electrical connections etc. (s) Checking of earthing resistance (t) Cleaning of vegitation around the DG set up to 1.5 mtr area. (u) Checking Coolant Level in radiator,top it up if reqd with premix coolant. (v) Checking of vacuum indicator for air restriction. (w) Cleaning of complete engine incl alternator and outer Canopy(i) 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 ,Location : Power House(Total 02 Nos) |
| 2 | Ditto all as per item No. 1 above but320 KVA Capacity, Make :Cromption Greaves, 318/6002-DG/08, Location : Manoj Pandey Bldg |
| 3 | Ditto all as per item No. 1 above but320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14, Location : Vyas Library |
| 4 | Ditto all as per item No. 1 above but200 KVA Capacity, Make :Cromption Greaves, 318/6003-DG/08, Location : ATT |
| 5 | Ditto all as per item No. 1 above but160 KVA capacity, Make : Kirloskar, 318/6008/DG/2011 , Location : MH Khadakwasla |
| 6 | Ditto all as per item No. 1 above but125 KVA Capacity, Make : Kirlosakar,318/6076/DG/13, Location : NDA Area (Trolley Mounted) |
| 7 | Ditto all as per item No. 1 above but82.5 KVA Capacity, Make : Kirloskar, 318/6006/DG/11, Location : VIPAREA |
| 8 | Ditto all as per item No. 1 above but62.5 KVA Capacity, Make : Kirloskar, 318/6009/DG/13, Location : Power Houser (MIS Cell) |
| 9 | Ditto all as per item No. 1 above but50 KVA Capacity, Make : Kirloskar, 318/6015/DG/2011, Location : New Pashan Gate / Trishakti gate |
| 10 | Ditto all as per item No. 1 above but50 KVA Capacity, Make : Cummins, 318/6001-DG/04, Location : AFTT |
| 11 | Ditto all as per item No. 1 above but50 KVA Capacity, Make : Kirloskar, 318/6054/ACT/15, Location : AFTT (Addl Hanger) |
| 12 | Ditto all as per item No. 1 above but25 KVA Capacity, Make :Kirloskar, Location : AFTT (HRDF) |
| 13 | Ditto all as per item No. 1 above but5 KVA Capacity, Make :Cromption Greavesr, Location :Tower 6 |
| 14 | Ditto all as per item No. 1 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 10 |
| 15 | Ditto all as per item No. 1 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 11 |
| 16 | Ditto all as per item No. 1 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 16 |
| 17 | Ditto all as per item No. 1 above but1 KVA Capacity, Make :Birla Power Solutions, Location : Hydraulic lift |
| 18 | Ditto all as per item No. 1 above but250 KVA Capacity, Make :Cromption Greaves, 1308062408426, Location : Manoj Pandey Bldg |
| 19 | Ditto all as per item No. 1 above but250 KVA Capacity, Make :Cromption Greaves, 1308062408423, Location : Power house |
| 20 | B\" Check once in Six month OR 250 Hrs running of DG set whichever is Earlier : Material and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :-(a) Repeat the activities of \"Á\" Check (b) Replacment of of lubricant oil. (Note:- Lub Oil are Paid separately.) (c) Replacing lubricant oil filter element with \"O\" ring (d) Replacing fuel filter element (e) Replacing coolant.(f) Replacing Governer oil. Notes(g) Cleaning of filter head (h) Checking of fan hub and fan drive arrangement (j)Checking of electrolyte level and specific gravity of battery (k) Checking terminals tightness and clean the battery: B Check kit, coolent shall and Lubricant oil shall be measured and paid separately under relevent items. 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 ,Location : Power House(Total 02 Nos) |
| 21 | Ditto all as per item No20 above but320 KVA Capacity, Make :Cromption Greaves, 318/6002-DG/08, Location : Manoj Pandey Bldg |
| 22 | Ditto all as per item No20 above but320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14, Location : Vyas Library |
| 23 | Ditto all as per item No20 above but200 KVA Capacity, Make :Cromption Greaves, 318/6003-DG/08, Location : ATT |
| 24 | Ditto all as per item No20 above but160 KVA capacity, Make : Kirloskar, 318/6008/DG/2011 , Location : MH Khadakwasla |
| 25 | Ditto all as per item No20 above but125 KVA Capacity, Make : Kirlosakar,318/6076/DG/13, Location : NDA Area (Trolley Mounted) |
| 26 | Ditto all as per item No20 above but82.5 KVA Capacity, Make : Kirloskar, 318/6006/DG/11, Location : VIPAREA |
| 27 | Ditto all as per item No20 above but62.5 KVA Capacity, Make : Kirloskar, 318/6009/DG/13, Location : Power Houser (MIS Cell) |
| 28 | Ditto all as per item No20 above but50 KVA Capacity, Make : Kirloskar, 318/6015/DG/2011, Location : New Pashan Gate / Trishakti gate |
| 29 | Ditto all as per item No20 above but50 KVA Capacity, Make : Cummins, 318/6001-DG/04, Location : AFTT |
| 30 | Ditto all as per item No20 above but50 KVA Capacity, Make : Kirloskar, 318/6054/ACT/15, Location : AFTT (Addl Hanger) |
| 31 | Ditto all as per item No20 above but25 KVA Capacity, Make :Kirloskar, Location : AFTT (HRDF) |
| 32 | Ditto all as per item No20 above but5 KVA Capacity, Make :Cromption Greavesr, Location :Tower 6 |
| 33 | Ditto all as per item No20 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 10 |
| 34 | Ditto all as per item No20 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 11 |
| 35 | Ditto all as per item No20 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 16 |
| 36 | Ditto all as per item No20 above but1 KVA Capacity, Make : Cromption Greaves Location : Hydraulic lift |
| 37 | Ditto all as per item No20 above but250 KVA Capacity, Make :Cromption Greaves, 1308062408426, Location : Manoj Pandey Bldg |
| 38 | Ditto all as per item No20 above but250 KVA Capacity, Make :Cromption Greaves, 1308062408423, Location : Power house |
| 39 | Supply only B check kit for DG set of following capacities :-Note :It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element(a)320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 ,Location : Power House(Total 02 Nos) |
| 40 | Ditto all as per item No 39 above but320 KVA Capacity, Make :Cromption Greaves, 318/6002-DG/08, Location : Manoj Pandey Bldg |
| 41 | Ditto all as per item No 39 above but320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14, Location : Vyas Library |
| 42 | Ditto all as per item No 39 above but200 KVA Capacity, Make :Cromption Greaves, 318/6003-DG/08, Location : ATT |
| 43 | Ditto all as per item No 39 above but160 KVA capacity, Make : Kirloskar, 318/6008/DG/2011 , Location : MH Khadakwasla |
| 44 | Ditto all as per item No 39 above but125 KVA Capacity, Make : Kirlosakar,318/6076/DG/13, Location : NDA Area (Trolley Mounted) |
| 45 | Ditto all as per item No 39 above but82.5 KVA Capacity, Make : Kirloskar, 318/6006/DG/11, Location : VIPAREA |
| 46 | Ditto all as per item No 39 above but62.5 KVA Capacity, Make : Kirloskar, 318/6009/DG/13, Location : Power Houser (MIS Cell) |
| 47 | Ditto all as per item No 39 above but50 KVA Capacity, Make : Kirloskar, 318/6015/DG/2011, Location : New Pashan Gate / Trishakti gate |
| 48 | Ditto all as per item No 39 above but50 KVA Capacity, Make : Cummins, 318/6001-DG/04, Location : AFTT |
| 49 | Ditto all as per item No 39 above but50 KVA Capacity, Make : Kirloskar, 318/6054/ACT/15, Location : AFTT (Addl Hanger) |
| 50 | Ditto all as per item No 39 above but25 KVA Capacity, Make :Kirloskar, Location : AFTT (HRDF) |
| 51 | Ditto all as per item No 39 above but5 KVA Capacity, Make :Cromption Greavesr, Location :Tower 6 |
| 52 | Ditto all as per item No 39 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 10 |
| 53 | Ditto all as per item No 39 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 11 |
| 54 | Ditto all as per item No 39 above but5 KVA Capacity, Make :Cromption Greaves, Location : Tower 16 |
| 55 | Ditto all as per item No 39 above but250 KVA Capacity, Make :Cromption Greaves, 1308062408426, Location : Manoj Pandey Bldg |
| 56 | Ditto all as per item No 39 above but250 KVA Capacity, Make :Cromption Greaves, 1308062408423, Location : Power house |
| 57 | Supply only coolent, K cool super plus 50-50 Premix |
| 58 | Supply only Batterydistill water with electrolyte mix |
| 59 | Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil |
| 60 | Material and labour for replacement ofunserviceable battery 12 V, 180 AH with maintenance free battery 12 Voltinitially charged. Make - Exide / Amaron |
| 61 | Material and labour for replacement ofunserviceable battery 12 V, 150 AH with maintenance free battery 12 Voltinitially charged. Make - Exide / Amaron |
| 62 | Material and labour for replacement ofunserviceable battery 12 V, 90 AH with maintenance free battery 12 Voltinitially charged. Make - Exide / Amaron |
| 63 | Material and labour for replacement ofunserviceable battery 12 V, 40 AH with maintenance free battery 12 Voltinitially charged. Make - Exide / Amaron |
| 64 | Dismaintling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back incl necessary welding brazing as required , refixing , reconnecting and testing for proper functioning :-(a) 5 / 25 /50KVA Capacity |
| 65 | (b)Ditto all as per item No 64 above but62.5/82.5 KVA Capacity |
| 66 | (c)Ditto all as per item No 64 above but160 /125 KVA Capacity |
| 67 | (d)Ditto all as per item No 64 above but200 KVA Capacity |
| 68 | (e)Ditto all as per item No 64 above but320 KVA Capacity |
| 69 | (f)Ditto all as per item No 64 above but250 KVA capacity |
| 70 | Dismaintling, removing the alternator /dynomo of from the engine of following capacity of DG Sets, opening up over hauling servicing, replcement of carbon brushes with holders, assembling back, refixing and testing for proper function.(a) 5 / 25 /50KVA Capacity |
| 71 | (b)Ditto all as per item No 70 above but62.5/82.5 KVA Capacity |
| 72 | (c)Ditto all as per item No 70 above but160 /125 KVA Capacity |
| 73 | (d)Ditto all as per item No 70 above but200 KVA Capacity |
| 74 | (e)Ditto all as per item No 70 above but320 KVA Capacity |
| 75 | (f)Ditto all as per item No 70 above but250 KVA capacity |
| 76 | Dismantling , removing the self startor from the engine of following capacity DG Sets , opening up , over hauling/ servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function :(a)5 / 25 /50KVA Capacity |
| 77 | (b)Ditto all as per item No 76 above but62.5/82.5 KVA Capacity |
| 78 | (c)Ditto all as per item No 76 above but160 /125 KVA Capacity |
| 79 | (d)Ditto all as per item No 76 above but200/250 KVA Capacity |
| 80 | (e)Ditto all as per item No 76 above but320 KVA Capacity |
| 81 | Dismantling of fuel injector assembly complete from the engine of following capacity of DG Sets, reconditioning/ serving, replacement of pim spiral, washers, Cup injector,retainer, Cup screw etc assembling calibiration, setting for proper function refixing and testing for:(a) 5 / 25 /50KVA Capacity |
| 82 | (b)Ditto all as per item No 81 above but62.5/82.5 KVA Capacity |
| 83 | (c)Ditto all as per item No 81 above but160 /125 KVA Capacity |
| 84 | (d)Ditto all as per item No 81 above but200/250 KVA Capacity |
| 85 | (e)Ditto all as per item No 81 above but320 KVA Capacity |
| 86 | Disconnecting all the connections from alternator of DG Set of following Capacityremoving the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing clening all the parts with thinner and varnishing completely with F class varnishing, applaying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed.(a) 5 / 25 /50KVA Capacity |
| 87 | (b) Ditto all as per item No 86 above but62.5/82.5 KVA Capacity |
| 88 | (c)Ditto all as per item No 86 above but160 /125 KVA Capacity |
| 89 | (d)Ditto all as per item No 86 above but200/250 KVA Capacity |
| 90 | (e)Ditto all as per item No 86 above but320 KVA Capacity |
| 91 | M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14including connecting and testing all as specified and directed.(a) Fuel Pipe |
| 92 | (b)Ditto all as per item No 91 above butAir filter (inner & Outer) |
| 93 | (c)Ditto all as per item No 91 above but V Belt |
| 94 | (d)Ditto all as per item No 91 above but Water Pump Kit |
| 95 | (e)Ditto all as per item No 91 above butOil filter |
| 96 | (f)Ditto all as per item No 91 above butRadiator Hose |
| 97 | M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA Capacity, Make :Greaves Cotton, 318/6004/DG/09,318/6005/DG/09including connecting and testing all as specified and directed.(a) Air filter inner and outer |
| 98 | (b)Ditto all as per item No 97 above but V belt |
| 99 | (c)Ditto all as per item No 97 above butFuel Pipe |
| 100 | (d)Ditto all as per item No 97 above but Battery terminals |
| 101 | (e)Ditto all as per item No 97 above butBattery Lead (Red & Black) |
| 102 | (f)Ditto all as per item No 97 above butOil filter |
| 103 | (g)Ditto all as per item No 97 above butRadiator house |
| 104 | (h)Ditto all as per item No 97 above but Turbo Charger Repair Kit |
| 105 | M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA Capacity, Make :Greaves Cotton, 318/6002/DG/08including connecting and testing all as specified and directed.(a) Air filter inner and outer |
| 106 | (b) Ditto all as per item No 105 above but V belt |
| 107 | (c)Ditto all as per item No 105 above but Fuel Pipe |
| 108 | (d)Ditto all as per item No 105 above butBattery terminals |
| 109 | (e)Ditto all as per item No 105 above but Battery Lead (Red & Black) suitable for 180Amps |
| 110 | (f)Ditto all as per item No 105 above but Oil filter |
| 111 | (g)Ditto all as per item No 105 above butTurbo Charger Repair Kit |
| 112 | M & L for replacement of defective spare parts of DG Sets of capacity 200 KVA Capacity, Make :Cromption Greaves, 318/6003-DG/08 including connecting and testing all as specified and directed.(a) Oil filter |
| 113 | (b)Ditto all as per item No 112 above butAir filter Inner |
| 114 | (c)Ditto all as per item No 112 above but Turbo charger repair Kit |
| 115 | (d)Ditto all as per item No 112 above butWater Pump Assembly |
| 116 | M & L for replacement of defective spare parts of DG Sets of capacity 82.5 KVA Capacity, Make :Kirloskar, including connecting and testing all as specified and directed.(a)Air filter |
| 117 | (b)Ditto all as per item No 116 above but V belt |
| 118 | (c) Ditto all as per item No 116 above but Fuel Pipe |
| 119 | (d)Ditto all as per item No 116 above but Battery terminals |
| 120 | (e)Ditto all as per item No 116 above but Battery Lead (Red & Black) |
| 121 | (f)Ditto all as per item No 116 above but Radiator Hose |
| 122 | (g)Ditto all as per item No 116 above but Oil filter |
| 123 | M & L for replacement of defective spare parts of DG Sets of capacity 160/125KVA,including connecting and testing all as specified and directed.(a)Air filter |
| 124 | (b)Ditto all as per item No 123 above but V Belt |
| 125 | (c) Ditto all as per item No 123 above butHose Pipe Set |
| 126 | (d)Ditto all as per item No 123 above butOil filter |
| 127 | (e)Ditto all as per item No 123 above butTurbo Charger repair kit |
| 128 | M & L for replacement of defective spare parts of DG Sets of capacity 62.5 KVA Capacity, Make : Kirloskar, 318/6009/DG/13including connecting and testing all as specified and directed.(a)Air filter |
| 129 | (b)Ditto all as per item No 128 above but V Belt |
| 130 | (c)Ditto all as per item No 128 above but Hose Pipe Set |
| 131 | (d)Ditto all as per item No 128 above but Oil filter |
| 132 | M & L for replacement of defective spare parts of DG Sets of capacity 50KVA,including connecting and testing all as specified and directed.(a) Air Filter |
| 133 | (b)Ditto all as per item No 132 above butV Belt |
| 134 | (c)Ditto all as per item No 132 above but Hose Pipe Set |
| 135 | M & L for replacement of defective spare parts of DG Sets of capacity 25 KVA Capacity, Make :Kirloskarincluding connecting and testing all as specified and directed.(a)Air filter |
| 136 | (b)Ditto all as per item No 135 above butV Belt |
| 137 | (c)Ditto all as per item No 135 above butHose Pipe Set |
| 138 | M & L for replacement of defective spare parts of DG Sets of capacity 5 KVA Capacity, Make :Cromption Greavesincluding connecting and testing all as specified and directed.(a) Air Filter |
| 139 | (b)Ditto all as per item No 138 above but V Belt |
| 140 | (c)Ditto all as per item No 138 above but Hose Pipe Set |
| 141 | (d)Ditto all as per item No 138 above but Wiring kit |
| 142 | M & L for replacement of Door Hinges as per sample incl welding of various capacity of DG Set all as specified and directed. |
| 143 | Supply and fixing battery lead with negative & Positive brass terminals of suitable size with 3 m length of each lead all as specified and directed |
| 144 | M & L for complete checking of AMF panel,finding the fault,servicing complete including replacement of unserviceable spares and testing complete for manual & Auto operations all as specified and directed. Note:- Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule. |
| 145 | Supply only Auto M ains Failure (AMF)Relay with protection features such as Under Voltage, Over Voltage,Over frequency,Low oil presure(LLOP),High coolant temperature(HWT) and Emergency Stop,LCD display for Voltage,Frequency ,Current and alarm status, Auto& Mannual Mode, and compliance with relevant safety and performance standards for undermentioned capacity DG sets.all as specified and directed(a) For 320 KVA to 200 KVA |
| 146 | (b)Ditto all as per item No 146 above but For 160 KVA to 50 KVA |
| 147 | M&L for replacement of UNSV contactor AC operated 4 pole 415 volts, AC-1 rating suitable for the following capacity of DG set all as specified and directed (a) DG set 320 KVA,560A with auxillary contacts 2NO+2NC |
| 148 | (b)Ditto all as per item No 148 above but DG set 250 KVA,360A with auxillary contacts 2NO+2NC |
| 149 | (c)Ditto all as per item No 148 above but DG set 200 KVA,325A with auxillary contacts 2NO+2NC |
| 150 | (d)Ditto all as per item No 148 above but DG set 160 KVA,255A with auxillary contacts 2NO+2NC |
| 151 | (e)Ditto all as per item No 148 above butDG set 125 KVA,200A |
| 152 | (f)Ditto all as per item No 148 above but DG set 82.5 KVA,130A |
| 153 | (g)Ditto all as per item No 148 above but DG set 62.5 KVA,105A |
| 154 | (h)Ditto all as per item No 148 above but DG set 50 KVA,80A |
| 155 | (j)Ditto all as per item No 148 above butDG set 25KVA,40A |
| 156 | (k)Ditto all as per item No 148 above butDG set 5KVA,18A |
| 157 | M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 320 KVA /250 KVA/ 200 KVA all as specified and directed |
| 158 | M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 160 KVA /125 KVA all as specified and directed |
| 159 | M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 82.5 KVA /62.55 KVA |
| 160 | S&F single phase preventor SPPR type SDz5, SPPR + Timer, 415 volts, 50 Hz, suitable for 3 phase DG Panel all as specified and directed.Make :L&T Cat No XM81809OOOO or SEIMENS or BCH |
| 161 | S&F Electronic timers type ST100 , 415 volts, 50 Hz, suitable for 3 phase DG Panel all as specified and directed.Make :L&T Cat No ST80328OOOO or equivalent |
| 162 | S&F in replacement of window glass of canopy of capacity 320 KVA all as specified and directed |
| 163 | S&F in replacement of window glass of canopy of capacity 50 KVA all as specified and directed |
| 164 | S&F in replacement of heat proof asbestos rope 12 mm to 20 mm dia on engine exhaust pipe including dismataling of worn out asbestos rope and minor welding tightening in leakage of exhaust pipe complete all as directed confirming to IS specifications of fire proof/flame proof all as specified and directed |
| 165 | Taking outold unserviceable battery charger from the following DG sets replacemnt with the following battery charger ofundermrntionedcapacity with test certificate s all as specified and directed. |
| 166 | S&F Automatic Battery charger 24 volts 10 Amps capacity floor mounted suitable for 200/250/320 KVA DG set with features Automatic Selection of FLOAT and BOOST mode complete all as specified and directed. |
| 167 | S&F Automatic Battery charger 12 volts 20 Amps capacity floor mounted suitable for 160/125 KVA DG set with features Automatic Selection of FLOAT and BOOST mode complete all as directed. |
| 168 | S&F Automatic Battery charger 12 volts 10 Amps capacity panel mounted suitable for 5/25/50/62.5/82.5 KVA DG set with features Automatic Selection of FLOAT and BOOST mode complete all as directed. |
| 169 | Material & labourcement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed . |
| 170 | Material & labour PCC 1: 3 : 6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in stays and coping of poles including necessary form work complete all as specified and directed. |
| 171 | M&L for hardcore of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces in broken stone or boulder complete all as specified and as directed . |
| 172 | Surface excavationn exc 30 cm depth and averaging 15 cm depth and getting out in soft /loose soil including clearing away all grass and vegitation saplings , shrubs , bushes , undergrowth roots and removing rubbish upto a distance n exc 50 mtrs outside the perifery of the transformer/ 2 pole /4 pole structure/ feeder pillar area complete all as specified and directed.(Note:-The contrator will ensure that no vegitation grows during the contract period on the area so excavated |
| 173 | M&L cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, as required, in the case of metal exc 3mm thick but not exceeding 6mm thickrunning welding in repairs all as specified and directed. |
| 174 | M&L in replacement ofMild steel chequered plate 10mm thick for ducting edges beaded if directed,holes punched included round headed screws complete all as specified and as directed. |
| 175 | S&F in replacement self starter suitable for 12 Volt DC operation complete all as specified and as directedMake - Lucas including disconnecting and taking down the existing unserviceable self starter & depositing to MES store yard. |
| 176 | S&F in replacement self starter suitable for 24 Volt DC operation complete all as specified and as directedMake - Lucas including disconnecting and taking down the existing unserviceable self starter & depositing to MES store yard. |
| 177 | S&F Fuel level pipe of 10 mm dia including taking down existing one complete all as specified and directed. |
| 178 | S & F control wiring of 1.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters etc. including suitable size of copper lugs, pvc CABLE ducts , suitable size of galvanised or cadmium plated high tensile nuts, bolts and washers etc all as specified and directed. |
| 179 | S & F control wiring of 2.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc all as specified and directed. |
| 180 | S & F in replacement power contactors of AC3 80 Amps 3 Pole 415 volts including taking down existing one all as specified and directed. |
| 181 | S & F in replacement power contactors of AC3 25 to 63 Amps 4 Pole 415 volts including taking down existing one all as specified and directed. |
| 182 | S & F in replacement of MCCB 3P 630 amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 183 | S & F in replacement ofMCCB 4P 500 amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 184 | S & F in replacement of MCCB 4P 400 amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 185 | S & F in replacement ofMCCB 4P 320 amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 186 | S & F in relacement of MCCB 4P 250 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 187 | S & F in replacement of MCCB 4P 200 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 188 | S & F in replacement ofMCCB 4P 160 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 189 | S & F in replacement of MCCB 4P 125 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 190 | S & F in replacement ofMCCB 4P 100 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 191 | S & F in replacementof MCCB 4P 54-80 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed. |
| 192 | S& F HRC Fuses DIN type 200 Amp Type FN/FNX with fuse base type HB including taking down existing one, drilling, screwing etc all as specified and directed.Make:L&T or equivalent |
| 193 | Ditto all as per item no 65 above but 125 Amp Make:L&T or equivalent |
| 194 | Ditto all as per item no 65 above but 250 Amp Make:L&T or equivalent |
| 195 | Ditto all as per item no 65 above but 315 Amp Make:L&T or equivalent |
| 196 | Ditto all as per item no 65 above but 400 Amp Make:L&T or equivalent |
| 197 | Ditto all as per item no 65 above but 500 Amp Make:L&T or equivalent |
| 198 | Demolition pre cast block walling built in cement mortar or cement lime mortar complete all as specfied and directed |
| 199 | M&L Pre-cast cement concrete blockmasonry withsolid blocks, exc. 10cm in width andsetting in mortar,complete in cm 1:6 type C1 using 1:3:6 using 20mm aggregate all as specified and directed |
| 200 | M&L for rendering 15mm thick cement plaster in CM( 1:6) on block walling surface finished even and smooth without using extra cement complete all as specified and directed. |
| 201 | M&L for two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or grith including preparation of New surfaces andone coat of Red oxide primer complete all as specified and directed. |
| 202 | Materialand labour for Retro Reflective installation sign boards size made out of 3mm thick acrylic fexible sheet of 2.5m x 1m x 20cmfabricated out of14 SWG MS sheet frame duly welded /riveted with square pipe of size 25mm x 25mm at height 2.25 meter on 50x50 mm angle iron frame – 02 Nos fixed with PCC 1:2:4 type B-1 Block of size 45x45x60cm The board shall be painted in stove enameled paint and the front of the frame shall be overall sheathed with blue colour base and including LED 1x20 watt fitting04Nos with internal wiring completeletters of white colour allas per specimen provided and all as specified & directed |
| 203 | Taking down old unsv AMF panel of 320KVA DG set incl connected cables and shifting the load in new AMF panel incl demilition of PCC fondation all as specified and directed |
| 204 | Material andlabour for AMF Panelfabricated with 16/14 SWGthick CRCAsheet, epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish and seven tank pre treatment process.The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof.All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable.The panel shall be provided with aluminium bus bars, 500Amps electrolytic grade of adequate rating.The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix accordingly.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers.The panel shall be provided with 04 Nos 25mmx25mmx3mm thick angle iron supports of not less than each 0.6 mtr heightduly painted with anti corrosive black paint and grouted on floor/wall etc and suitable fixing arranement as per site requirement connection to the existing earthing.The overall size of the AMF panel shallbe 2000mm x900mmmx450mm (HxWxD).including PCC 1:3:6 and Panel shall be of CPRI approved and connected to existing electrical system complete all as specified and directed . Suitable for 320 KVA DG set, double contactor type in and including the following parts, Location : Power House(i) Microprocesor based AMF relay with in built engine and alternator parameters 415 V/12 V DC =01 Set (ii)HRC FUSE & Base unit500A =03Nos (iii)MCCB 3 Pole 500A =02 Nos (iv)Contactor 4 Pole,500A, 240 V AC-1 Duty =02 (v) Main and DG control MCB TP 6A=7Nos (vi) Line Voltage Monitor three phase/440V=01No (vii) Current Transformer 600/5 Class I=03Nos (viii)Earth Fault CT, 100/5 , 5P5=01 No (ix) Earth Fault Relay 240 v & 5A=01 ,No (x) SMPS battery charger with Auto Cut Off 24 V/10A=01No (l) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=03Nos ,(xi) DC Voltmeter 0-40V and Ammeter 0-15A=02Nos ,,(xii) Main andDG auxillary timer 240V AC /10A =02 Nos,(xiii)Digital MF meter (v,A,KWH,KW,PF)3 phase/440V & 5A =01No (Xiv) Control wire kit AC & DC 1.5 sqmm & 2.5 Sqmm(xv) LED Indication Lamp 240V = 09 Nos (xvi) Aluminium Bar 50 mmx10mm=04Nos(xvii) DC control fuse rating 240V/10A =4Nos(xviii) DC control fuse Link (glass Fuse) 01 A=4Nos(xix) DC contrlON/OFF selectorswitch,2 Pole,1 way 16A=01No Notes:(a) The panel Shall be powder coated made out of 1.6mm CRCA steel sheet (b) 3mm thick removable gland cover plate with suitable glandsholes for I/P and control cables as per size of cables to be provided. (c ) Closed rubbergrommets to be provided for power cable and wiring harness entry holes.(d) Front door shall be strenghtened by use of proper stiffners and sturdy hinges,knob(stainless steel) type door locks.(e) Colour coded wires shall be used for AC Circuits (f) IP 41 protection (g) Lug bolting on busbars should be located vertically and horizontally centered with ref to gland holes. (h) FRP/Epoxy sheet shrouding should be used for MCCB incoming(j) Length of control wiring harness shall be minimum 150 mm inside panel and male female connector coupling shall be inside panel (k)PVC cable tray should be provided for measuring and protective circuit. |
| 205 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanised iron strip 32 x 6 mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by15 mm dia (medium grade) including concrete pit in PCC (1:3:6) type C-1,RCC cover slab 55 cm x 55 cm x 5 cm withreinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and20 mm bore galvanised iron pipe\"medium grade\" for watering with GI funnel and wire mess including charcoal and salt in alternate layersof 15 cm including necessary excavation and earth work in any type of soil complete and testing on completion all as specified and as directed |
| 206 | M&L 32x6mm galvanised iron strip Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required at site all as specified and directed |
| 207 | M&L for Diesel Exhaust Fluid (DEF) Aqueous Urea Solution for reduction of NOX emissionsin 10 Litre Pack ,Commercial name Greaves Air GuardMake Greaves Cotton Limited |
| 208 | M&L for replacement ofunsv galvanised steel conduit at AMF panel and small DG wiring all as specified and directed. |
| 209 | Supply & Laying, jointing & testing of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 185 sqmm 3.5 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed |
| 210 | All as per item No 210 above but size 50 sqmm 3.5 core |
| 211 | All as per item No 210 above but size 70 sqmm 3.5 core |
| 212 | Taking out existing defective worn out UG LT cable of any size 1100 volts grade from trenches of any size from different locations incl brick bats etc complete and depositing to store, all as specified and directed . Note:Excavation & earth work shall be measured and paidseparately |
| 213 | Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed. |
| 214 | Excavation in trenches in soft/dis integrated rock n exc 1.5mwide and n.exc 1.5m in depth and getting out complete all as specified and directed. |
| 215 | Returning, filiing in incl spreading, leveling watering and well ramming excavated soil inlayers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested as specified and drected. |
| 216 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified and directed. |
| 217 | M&L in replacement for laying of reinforced concrete pipe,dia of150 mm 2 nos half round for bottom and top and before laying excaved area shall be levelling all as specified and directed by Engr-In- Charge . Note: One half round Top and One half round bottom together will be considered as one running meter.Make as per sample approved by Engr-In-Charge |
| 218 | M&L preperation of old/new steel surfaces over 10 cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint over a coat of red oxide primer. |