Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-10-2025 |
| 2 | 29-09-2025 | CORRIGENDUM | BOQ | 23-10-2025 |
| Sl. No. | Item Description |
| 1 | Repair / maintenance of street / security lights any type, flood lights, post top lanterns or any other external lights in its position fixed on pole /building structure or by taking down to ground, if required, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like electronic driver,surge protection device(SPD) connection wires/ cable, MCB etc including refixing the fittingto its original position (if taken down), including repair / maint of street light control timer & junction box all as directed .Note:(i)The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Cost of spareselectronic driver, connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch \"A\" here-in-below.(iii) The contractor\"s representative will report to concerned JE E/M at 0900hrs daily to collect the list of defective street light fittings and will submit the completion report on the same daybefore 1730hrs to the JE E/M.(iv) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments and clothings to his men and department shall not be responsible for any kind of mishap / accident / injury to his men. (v) The contractor has to rectify the defects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M.In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall carry out repair / maint work simultaneously JCOs/OR and followers residential area by engaging seprate team of electricians / technicians in order to ensure promptly & timely rectification of defects.(vi) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vii) The contractor shall maintain sufficient stock of spares / material required for repair / maint of street lights with the concerned JE E/M against the supply only items here-in-below. (viii) The details of street / security lights is enclosed as Appx A to Schedule A for general idea about the location and type of light fittings.(ix) Minimum 2x Electricians should be deployed to attend the complaints to ensure dusk to dawn serviceability of Street lights and ensure alternate arrangements to make fittings functionalall as specified and directed |
| 2 | Taking down the existing light fittings on multi mounting brackets from 16/21 mtrs highmast pole by taking on ground repairs/ replacing the defective parts like electronic drivers connection wires and refixing the same to its original position all as directed by Engr-In-Charge. Note:(i) Cost of spares , electronic drivers,connection wires replaced against above mentioned item above mentioned item will be measured & paid for separately under respective items of Sch \"A\" here-in-below.(ii) The defects / repair of the floodlight making them functional after handing over defective floodlights of highmast(iii) Maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every flood light and gettingit authenticated. (iv) Safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained. |
| 3 | Supply only following street light spares of branded make as mentioned in the list of make enclosed with Particular specifications for replacement under respective item above :-(a)Electronic driver suitable for 90watts LED security light fittings Make should be as per the Existing manufacturer. |
| 4 | (b) Electronic driver for 30/40/ 45 / 48 / 50/60 watts LED road way/Flood light/post top Make should be as per the Existing manufacturer |
| 5 | (c) Electronic driverfor 400/300 watts flood lights Make should be as per the Existing manufacturer |
| 6 | (d) Electronic driverfor 200 watts flood lights Make should be as per the Existing manufacturer |
| 7 | (e) All as item No 3 above but Electronic driver for 150 watts flood lights Make should be as per the Existing manufacturer |
| 8 | (f) Electronic driverfor 100 watts flood lights Make should be as per the Existing manufactureAll as item No 3 above butr |
| 9 | (g) MCB SP 230 volts B curve 6 amps |
| 10 | (h) MCB DP 230 volts C curve 6 amps |
| 11 | (j) MCB TPN 415 volts C curve 63 amps |
| 12 | (k) MCB TPN 415 volts C curve 40 amps |
| 13 | (l) Digital time switch, DIN type daily / weekly with 25ON/OFF programmes , 16 amps 250volts AC all as specified and directedMake Make L&T,Legrand,Havells,ABB |
| 14 | (m) Power contactor 40 amps 3 pole Make L&T,Legrand,Havells,ABB |
| 15 | (n) PVC insulated Copper conductor FRLS grade two core cable 2.5 sqmm, ISI marked |
| 16 | (o) PVC insulated aluminium conductortwo core round cable 4 sqmm, ISI marked |
| 17 | (p) PVC insulated aluminium conductortwo core round cable 6 sqmm, ISI marked |
| 18 | (q) MCCB 63 Amps 4 pole 415 V 16 KA |
| 19 | M&Lfor straight through joint (epoxy) for PVC insulated and sheathed aluminium conductor under ground cableincl freud , thimbles, nut & bolts, washers etc and testing afterjointing for 16 sqmm to 35 sqmm 3.5 core complete, all as specified and directed |
| 20 | Supply & Laying, jointing & testing of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size including removal of existing cable all as specified and directed |
| 21 | All as per item No 20 above but size 16 sqmm 4 core |
| 22 | All as per item No 20 above but size 10sqmm 4 core |
| 23 | All as per item No 20 above but size 6 sqmm 4 core |
| 24 | All as per item No 20 above but size 4 sqmm 3 core |
| 25 | Excavation in trenches in any type of soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed. |
| 26 | Returning, filiing in incl spreading, leveling watering and well ramming excavated soil inlayers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested as specified and directed |
| 27 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified and directed. |
| 28 | Supply and laying in replacement of 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e coupler, Tee, elbow clamp for cable protection complete all as specified and directed . |
| 29 | Supply and fix in replacement of junction box thermo plast (weather proof) IP 66,on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size withconnector for connecting incomming and outgoing of cableincluding 01 No of MCB DP 06 Amps to control the pole light circuit andMS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directedMake Sintex Cat pat No GSJB-3020 or equivalent make as mentioned in list of makes in PS. |
| 30 | Supply and fix in replacement ofjunction box thermo plast (weather proof) IP 66,on flood light poles made out of thermoplastic of size 140mm x 140 mm x 95 mm size withconnector for connecting incomming and outgoing of cableincluding 01 No of MCB SP 6 Amps to control the pole light circuit andMS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed Make Sintex Cat pat No GSJB-1414 or equivalent make as mentioned in list of makes in PS. |
| 31 | S&F in replacement MCB DB 02 way SPN (single door)sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including MCB SPN 06 Amp 230V, 50 HZ,complete all as specified and directed |
| 32 | S&F in repair ofGI pipe bracket of 40 mm dia 1.2mtr long bend to shape for street light fitting made out of40 mm dia GI light grade pipe fixed on pole using new FI clamp including necessary new nut, bolt and washer complete all as specified and directed. |
| 33 | Supply & fix GI tubing light grade 40 mm dia isi marked appx 1 mtr to 1.5 mtr long with Flat Iron Base for mounting of Flood lightwith all fittings inclnut,bolt,washers suitable size all as specified and directed |
| 34 | S& F GI tubing light grade 50 mm dia ISI marked for bollard light with all fittings laid in trenches and fixed pole by flat ironclamps, nut,bolt,washers suitable size complete all as specified and directed. |
| 35 | S& F GI tubing light grade 80 mm dia ISI marked for bollard light with all fittings laid in trenches and fixed pole by flat ironclamps, nut,bolt,washers suitable size complete all as specified and directed. |
| 36 | Labour for trimming / pruning tree branches overhanging or interfering or obstructing electrical pole or street lights complete all as directed in such a way that theclearance between Street light pole and tree branches should not be less than 1.5 mtrs around the Pole/Fitting all as specified and directed |
| 37 | Material and labour for Tarmac bituminised road cutting by using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm forlaying of 80 MM mediumgrade GI pipe incl refilling and making good with Tarmac/ PCCduly matching with the existing surface all as specified and directed Note:1. Quoted rate shall be incl of 80 MM Gi pipe medium grade2. Quoted rate shall deemed to incl the cost of making good the disturbed surface. |
| 38 | Removing existing damaged reflected strips from pole supply and fixing of 2 inchwidth retro reflective tape fixed to Street light Poleswith red colour all as directed |
| 39 | Removing existing damaged reflected strips from pole supply and fixing of 2 inchwidth retro reflective tape fixed to Street light Poleswith yellow colour all as directed |
| 40 | Removing existing damaged reflected strips from pole supply and fixing of 2 inchwidth retro reflective tape fixed to Street light Poleswith whitecolour all as directed |
| 41 | Suply & fixing in replacement of 30 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and directed |
| 42 | Suply & fixing in replacement of 50 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and directed |
| 43 | S & F in replacement of 100 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed. |
| 44 | S & F in replacement of 150 watts flood light Warm white /White in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed. |
| 45 | S & F in replacement of 200 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed . |
| 46 | Suply & fixing in replacement of 300 watt LED flood light luminaire with separate driver assemble boxwith secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66, with suitable Mounting structure as per site requirement complete all as specified and directed |
| 47 | Supply and Fix in replacement integral LED aviation light comprising housing with polycarbonate enclosure, aviation light is to be fixed on highmast light frame complete all as specified and directed.Make : Make - Havells/Wipro,Halonix,Bajaj |
| 48 | S&Fin replacement ofLED 90watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixing to pole/wall with necessary nut, bolts and washers complete all as specified and directed. |
| 49 | S&F in repalacement ofLED 48/50watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl completefixed to pole/wall with necessary MS clamp accessories complete all as specified and directed. |
| 50 | Supply and Fixingin replacement outdoor gate lightwith 9W LED Bulb WW B22 with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new gate light as per site requirement and fixing arrangements complete all as specified and directed |
| 51 | Supply and Fixingin replacement outdoor gate lightwith 18W LED Bulb E 27 with Base with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new gate light as per site requirement and fixing arrangements complete all as specified and directed |
| 52 | Supply and Fixingin replacement outdoor gate lightwith 9W LED Bulb E 27 with Base with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new gate light as per site requirement and fixing arrangements complete all as specified and directed |
| 53 | Supply and Fixingin replacement outdoor Spike light12W LEDwith Base with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new gate light as per site requirement and fixing arrangements complete all as specified and directed |
| 54 | Supply and Fix in replacement integral 20Watt LED WW post top lantern black/ copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and accessorieson on existing GI Pipe of diametercomplete all as specified and directed. |
| 55 | Supply and Fix in replacement 70 Watt LEDpost top lantern, IP65 Protection, die cast aluminium, with LED engine & electronic driver designed for glare free symmetrical light distribution. complete with all accessorieson on existing pole of diametercomplete all as specified and directed. |
| 56 | Supply & fix in replacement 40 watt LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete all as specified and directed. |
| 57 | Supply and Fixing in replacement of1x18 watt WW (3000K) LED bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new bollard as per site requirement and fixing arrangements all as directed Note: Quoted rate shall includes PCC work as required. |
| 58 | M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT (07 to 08 Mtr) height above ground level , preparing surface for painting , applying two coats of aluminium paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site including making balck and white strips of 30 cms each upto 1.5 m above PCC muffs with black and white paint and marking of pole No 2 m above PCC muff, letter should not be longer than 6 cm height with 16 cm dia circle around the marked NO complete all as such specified and directed . |
| 59 | M&L for scrapping down and removing of old deteriorated paint from Post top lantern poles (RCC/GI) /(2 to 3 mtr) height above ground level , preparing surface for painting , applying two coats of black paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at sitecomplete all as such specified and directed. |
| 60 | S&F in replacement of HOT dip galvanised Octagonal pole 7 mtr height having across faces bottom side 155 mm top side 70 mm made out of 3 mm thick HT sheet steel plate along with base plate of size 260x260x16 mm thick and required nut ,bolts, sutable PCC foundation if reqd as per manufacture instructions all as specified and directed. |
| 61 | Supply, transport, errecting and fixing steel tubular swaged welded pole of over all height 9 m long complete type 410-SP-31 conforming to IS-2713 (Part I to III 1980 reaffm 2008with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., completeall as specified and directed Note: (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer.(iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer (iv)Pole below ground shall be tarred by one coat(v) Poles shall be numbered and the rate for above items shall be deemed to be inclusive in the quoted rate. |
| 62 | M&L PCC 1:3:6 type C-2 (using 40 mm size graded stone aggregates) Cement concrete in foundations, filling and mass concrete complete all as specifed and directed. |
| 63 | M&L PCC 1:2:4 type B-1 (using 20 mm size graded stone aggregates) as in coping of pole sand including formed work and demolition of existing coping complete all as specifed and directed |
| 64 | M&L for PCC 1:4:8 type D-2 (using 40 mm size graded stone aggregates) Cement concrete in foundations, filling and mass concrete complete all as specifed and directed. |
| 65 | S&F in replacement ofoutdoor digital timer switch distribution board, IP 65, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB, power contactor and 230V digital time switch for controlling LED/SV etc street lights ,including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement all as specified and directed |
| 66 | S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of3.15 mm thick CRCAsheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finishwith seven tank pre treatment process.The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof.All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable.The panel shall be provided with aluminium bus bars, 300mmX40mmX5mm(thickness) electrolytic grade of adequate rating.The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix horizontally.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers.The panel shall be provided with 04 Nos 25mmx25mmx3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted on wall (at Sudan Dome)and suitable fixing arranement as per site requirement.The overall size of the Busbar panel shallbe 350mmx200mmx400mm (LxBxH).including PCC 1:3:6 all as specified and directed |
| 67 | M & L for making hole on a street light pole top and bottom for entry of service wire of 1.5 sqmm disconnecting the existing service connection from junction box and fitting and same has been reconnecting to junction box and fitting complete all as specified and directed. |
| 68 | Dismantling/taking down thepole upto 16/21 metre height of high mast light by engaging suitable crane and repairing by replacing the unserviceable top pully of pole and other part such as winch motor, steel wire, power cable and servicing ,toping of oil and greasing the gear wheel assemblyand hoisting, refixing and connecting up complete all as specified and directed .Note :a)The repair oflight fittings and light fitting spares are measured and paid separately.b)Spares such as steel wire, power cable etc will be measured and paid separately. c) The entire work shall be carried out with well experienced professionals who undertake the high mast poles dismantling /repair works. d) Minor spares such as screws, bolt/nuts, grease etc shall provided by the contractor without any extra cost over and above the quoted rate. |
| 69 | Supply only stainless steel rope twisted of size10mm/6 mm dia with necessary connections proper binding on both sides from bottom drum mast top connecting hook complete all as specified and directed |
| 70 | Supply only gear box oil of grade EP 90/140 in standard packed/sealed container including drain out old gear box and filling up new gear box oil complete all as specified and directed Make : HP/Servo/valvoline |
| 71 | Disconnecting electric connectionand taking down carefullyFractional motor from highmast housing of any type and capacity as described below: -removing the burnt winding ofmotor rewinding with super enameled copper winding wire of suitable gaugeof matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and refixing to original position all as specified and directed |
| 72 | Supply only 3 phase induction motor of 1HP heavy duty 415 V AC50 Hz 1500 RPM Suitable for lifting of highmast winch all as specified and directedMake Crompton Greaves,,ABB, Kirloskar |
| 73 | S&F in replacement of cylindrical panel locks of suitable size or as per sample including drilling,cutting and welding etc in panel sheets without disturbing to other existing fitments complete all as specified and directed. |
| 74 | S&F in repalcement of old broken cold rolled mild steel hinges of existing busbar etc of suitable size or as per sample including welding and painting to match with existing colour of panel sheet etc complete all as specified and directed. |
| 75 | Disconnecting/taking down the steel tubular GI Pole which is titling/leaning by engaging suitable crane or manullaycomplete all as specified and directed |
| 76 | Breaking and removing old Cement concrete in street light pole coping , using breaker or hevy eqpt exct complete all as specifed and directed. |
| 77 | S&F in replacement of outdoorLED strip of 220 V linear flex in colourWW,with fixing tape and end cap and suitable driver and connector of suiatble and IP 65 protection complete ,Single phase, mountingon the ceiling/wall/piller as reqd at the site complete all as specified and directedMake: Jaquar/Philips/Havells/Bajaj Note : Cost ofaluminium profile will be measured & paid for separately under respective items of Sch \"A\" |
| 78 | S&F inaluminium profile with accessories includingmountingon the ceiling/wall as reqd at the site complete all as specified and directed |
| 79 | M&L for Provision of protective cover of 1.20 mtr high and suitable size & shape, made out of plain mild steel wire 3.15mm dia, galvanised class 3, in protection for Bollard light fitting and including necessary fixing arrengements to prevent th light fitting from any damage and theft all as specified and directed. |
| 80 | Taking down old unsv Façade lighting any any size along with all accessories all as specified and directed |
| 81 | Supply and fixing testing & commissioning ofColor changing RGBW surfacemounted Narrow/Medium/Wide beam luminaire suitable for outdoor applicationsofFacadeLighting,depending on design as per site requirement and directed by Engr-In-Charge.LuminairesshouldbeenabledwithhighpowerLEDs, shouldconsistsofanti-agingandanti-UVhighoptical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement.The luminaire should have options for various beam angles i.e. from 15⁰/25⁰/35⁰actual will depend on the design as per site requirement.RGBW LED luminaries having75W at steady state full intensity, Luminaire luminous flux range of 2800- 3080 Lumens. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment.Color renderingindexCRI≥80 for white LEDS\"sand powerfactorof complete luminaire ≥ 0.90, at full intensity.Luminaire should be provided with suitable integral/separate non-integral power supply unit.LumenmaintenanceofatleastL70@50,000burning hours at 25°C.Theluminaireshouldhavepowdercoatingpressuredie castaluminiumhousingwithminimum3-4mmthick safety glass.Ingress Protection ≥ IP 66. Impact resistance level ≥ IK 08. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%. Housing to have adjustable base bracket for angle adjustment sothatthelight directioncanbeadjustedto illuminate desired structural elements.Connectorsif used shouldbe IP67male/femaleconnectorsfor loop through wiring.The LED Luminaires and external drivers drivers if used should be BIS certified.The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted by the contractor before the installation of Luminaries all as specified and directed. Make - Bajaj /Havells / Philips / Wipro Note : Quoated rate includes scafffolding work for installation of luminaries as per site requirement and directed |
| 82 | Supply and fixing testing and commissioning ofColor changing RGBW surfacemounted Narrow/Medium/Wide/Elliptical beam luminaire suitable for outdoor applicationsofFacadeLighting,depending on design asper site requirementand directed. LuminairesshouldbeenabledwithhighpowerLEDs, shouldconsistsofanti-agingandanti-UVhighoptical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement.The luminaire should have options for various beam angles i.e. from 8⁰/15⁰/25⁰/35⁰/10⁰x60⁰/15⁰x45⁰ actual will depend on the design by the contractor and site requirement.RGBW LEDLumanaries having36 W at steady state full intensity, Luminaire luminous flux range of 2450- 2580 Lm. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment.Color renderingindexCRI≥80 for white LEDS\"sand powerfactorof complete luminaire ≥ 0.90, at full intensity.Luminaire should be provided with suitable integral/separate non-integral power supply unit.LumenmaintenanceofatleastL70@50,000burning hours at 25°C.Theluminaireshouldhavepowdercoatingextrudedaluminium alloy housingwithminimum3-4mmthick safety glass.Ingress Protection ≥ IP 66. Impact resistance level ≥ IK 07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%.Housing to have adjustable base bracket for angle adjustment sothatthelight directioncanbeadjustedto illuminate desired structural elements.Connectorsif used shouldbe IP67male/femaleconnectorsfor loop through wiring.The LED Luminaires and external drivers drivers if used should be BIS certified.The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory all as specified and directed.Make -Bajaj BA WW IN1 AS 36 W RGBW or equivalent inPhilips graze powercore Gen 5 or wipro Arcus LF27-601-040-CC-XX Note : Quoated rate includes scafffolding work for installation of luminaries as per site requirement and directed |
| 83 | M&L for replacementofColor changing RGBW surfacemounted Narrow/Medium/Wide/Elliptical beam luminaire suitable for outdoor applicationsofFacadeLighting,depending on design asper site requirementand directed by Engr-In-Charge. LuminairesshouldbeenabledwithhighpowerLEDs, shouldconsistsofanti-agingandanti-UVhighoptical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement.The luminaire should have options for various beam angles i.e. from 8⁰/15⁰/25⁰/35⁰/10⁰x60⁰/15⁰x45⁰ actual will depend on the design by the contractor and site requirement.RGBW LEDLumanaries having60W at steady state full intensity, Luminaire luminous flux range of 2450- 2580 Lm. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment. Color renderingindexCRI≥80 for white LEDS\"sand powerfactorof complete luminaire ≥ 0.90, at full intensity.Luminaire should be provided with suitable integral/separate non-integral power supply unit.LumenmaintenanceofatleastL70@50,000burning hours at 25°C. Theluminaireshouldhavepowdercoatingextrudedaluminium alloy housingwithminimum3-4mmthick safety glass.Ingress Protection ≥ IP 66. Impact resistance level ≥ IK 07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%.Housing to have adjustable base bracket for angle adjustment sothatthelight directioncanbeadjustedto illuminate desired structural elements.Connectorsif used shouldbe IP67male/femaleconnectorsfor loop through wiring.The LED Luminaires and external drivers drivers if used should be BIS certified.The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory.Make -Bajaj /Havells /PhilipsWipro Note : Quoated rate includes scafffolding work for installation of luminaries as per site requirement and directed |
| 84 | Supply and fixing in replacement of DMX Controller System with Standalone interfaces. Controller should deliver 512 DMX channels, the controller should have the provision to ugrade its channels upto 1536 by adding 2 more DMX universe. the controller should have new Nicolaudie Stand Alone engine (NSA) offering some great possibilities (multi-zone, extended triggers, 16-bit channels management...). the controller should offer multiple possibilities to trigger your lighting scenes: time/date, input ports, TCP/UDP commands. The controller should have LS Cloud (activation required) as an optional feature to manage your lighting controller from anywhere in the world, at anytime using internet connectivity. PC DMX IN triggers:Yes, Standalone DMX IN triggers: Only with 512 interfaces, External triggers: x8 dry contacts (5V) internal calendar: Yes, Backups of theinternal clock: Yes, 3weeks without power, Memory card: Yes microSD card, 4GB max, Input power voltage: 8-15V DC with power adaopter,. via USB(USB power supply included), Trigger lighting scenes using calendar triggers and conditional rules with New Stand Alone engine, using contact ports, RS232 or over Ethernet. Stand Alone mode with 99 scenes across 5 zones. Buttons: Rotary switch for scene selection. iPhone/iPad/Android remote and programming apps. Temperature: 0 to +50 C°, DMX Compatibility: 8 and 16 bit DMX fixtures, System Compatibility: Windows XP, Vista, 7, 8, 8.1, 10, MAC OS X(10.6 and +), Linux all as specified and directed. |
| 85 | Supply and fixing in replacement of DMX Splitter cum Booster ,Input Power- 100 to 240 VAC, auto-ranging, 50/60 Hz.,Housing rugged alluminium, Operation Temperature -17ºC ~ +55ºC (0ºF ~ 131ºF) , 5/6 output ports with 3/5-pin terminal sockets , each port should be optically isolated , Protection Rating IP20 including connection complete all as specified and directed. |
| 86 | Supply and fixing in replacement of IP65 Junction Boxes DK 0202G with Connector DK KH 04/ DK KL 04 complete all as specified and directed. Make : Hensel/Sintex/National |
| 87 | Supply and fix in replacement of Server RACK 9U for theDMX splitter and controller complete all as specified and dircted. Make: Valrack/D-link |
| 88 | Supply and fixing in replacementof Cat 06, 4 Pair twisted wire UTP 23 AWG pure copper unsheilded PVC Bulk Cable (305 mtr per roll) as per ISI/ BIS standard.Make : Havells/Polycab/Finolex |
| 89 | S&F in replacement for PVC insulated2.5 sqmm 4 core copper conductor FRLS grade ISI marked including PVC conduit pipes of dia not less than 19 mm complete all as specified and directed. |
| 90 | Supply & fixing in replacement of lighting control system along with versatile wall mounted button panel device acting as interface to trigger different themes as per site requirement complete all as specified and directed. |
| 91 | M&L for programming of software with 08 nos of themesby Qualified Rep of OEM all as specified and directedby Engr-in-Charge as per site requirement complete all as specified and directed. |
| 92 | M&L in replacement of Aluminum composite panelsheets (ACP Cladding ) including 1/1.5mm aluminium pipe including necessary harware such as drilling iron screws, double tape, silicon dow, masking tape etcas per site requirement complete all as specified and directed |
| 93 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 94 | M&L 4mm galvanised ironEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required at site all as specified and directed |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy