E-Bid For Rate Contract Cum Supply And Empanelment Of Surgical Items , Blood Administration Set / Blood Transfusion Set • Sharp And Easy Piercing Spike Suitable For Blood Bags And Standard Blood Containers • Transparent Cylindrical Drip Chamber With Filter.Filter Size Should Be 200+20 Micrometer. • 150 Cm Long Smooth Kink Resistant Tubing • Efficient Roller Clamp To Control And Adjust The Transfusion Rate • As Per Is9824 (Part 3):1996 , Suction Catheter, Sterile. Size: Fg 5 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cms (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 6 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 8(For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 10 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 12 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 14 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment. • Length 50 Cm (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 16 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 18(For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye •Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment. • Length 50 Cm (Min.) • As Per Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 20 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment. • Length 50 Cm (Min.). • As Per Is0 8836:2014. , Suction Catheter, Sterile. Size: Fg 22 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye. • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment. • Length 50 Cm (Min.). • As Per Is0 8836:2014 , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 8 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation. • Symmetrical Foley Balloon • Balloon Capacity3- 5 Ml • As Per Is 11497 • Color Coding Marking To Identify Size. • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specificationfor B,C,D,E,F,G Should Be Mentioned As Per Is 11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size10 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation. • Symmetrical Foley Balloon • Balloon Capacity3- 5 Ml • As Per Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specificationfor B,C,D,E,F,G Should Be Mentioned As Per Is 11497 For Particular Size. , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way,Size16 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity30 ± 1Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size. • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specificationfor B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way,Size18 Fg. • Made Of Silicone Elastomer Bonded With Latex. • Should Have Hard Plastic Valve. • Smooth Distal End With Smooth Eyes For Atraumatic Intubation. • Symmetrical Foley Balloon. • Balloon Capacity30 ± 1 Ml. • Should Conform To Is 11497. • Color Coding Marking To Identify Size. • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specificationfor B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size20 Fg. • Made Of Silicone Elastomer Bonded With Latex. • Should Have Hard Plastic Valve. • Smooth Distal End With Smooth Eyes For Atraumatic Intubation. • Symmetrical Foley Balloon. • Balloon Capacity30 ± 1 Ml. • As Per Is 11497. • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specificationfor B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size22 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation. • Symmetrical Foley Balloon. • Balloon Capacity30 ± 1 Ml. • As Per Is 11497. •Color Coding Marking To Identify Size. • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specificationfor B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 24 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity30 ± 1 Ml • As Per Is 11497 • Color Coding Marking To Identify Size. • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specificationfor B,C,D,E,F,G Should Be Mentioned As Per Is 11497 For Particular Size , Infant Feeding Tube Size:10Fg Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non- Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure •Radio Opaque Line • Sterile , Infant Feeding Tube Size:8Fg, Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non- Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure •Radio Opaque Line. • Sterile , Infant Feeding Tube Size:5Fg Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non- Toxic Pvc Tubing, Non Irritant To Delicate Mucosa. • With Female Flexible Mount With In-Built Closure. •Radio Opaque Line. • Sterile , Sterile Disposable Infusion Set With Microdrip (I.V.) • Microdrip Infusion Set With Drop Size Reduced To Approx 60 Drops Per Ml. • Sharp And Easy Piercing Spike. • Transparent And Flexible Drip Chamber. • 150 Cm Long Smooth Kink Resistant Tubing. • Efficient Roller Clamp To Control And Adjust The Fluid Rate. • As Per Is12655 - 4 Standard , Insulin Syringe ( 40 Units) With (Fixed) 30 G Needle As Per Is 12227 , Sterile Disposable (Single Use Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock.)Size 18G • Should Be Packed In Transparent, Single Blister Pack. • As Per Is 10555 Standard , Mucus Extractor Sterile • Clear Transparent Container • Antibacterial Filter • Soft, Kink Resistant Pvc Tubing • Tube Size 10 Fg; Length 40 Cm (Min.) • Capacity 25 Ml , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Adult) •Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages. • Connector For Easy Connection To The Oxygen Source. • Tube Length 200 Cm. , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Pediatrics) •Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source • Tube Length 200 Cm , Plaster Of Paris Bandages 10Cm X 2.7Mts / Roll Testing Parameter Should Be Followed As Per Bp Standard , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size:10 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size:12 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel• With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size:14 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size:16 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size:18 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Scalp Vein Set (Disposable): Size 18G •Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non- Toxic, Non Irritanttube • Sterile , Scalp Vein Set (Disposable): Size 20G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded •Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation •Female Luer Fitting At One End •Soft, Kink Resistant, Non- Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 22G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non- Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 24G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non- Toxic, Non Irritant Tube • Sterile , Sterile Disposable Spinal Needle For Single Use 22G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Sterile Disposable Spinal Needle For Single Use 25G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Endotracheal Tube, Plain - Size 2.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 3Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 3.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 4Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 4.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain- Size 5.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain With Radio-Opaque Line, Sterile, Single Use- Size 6Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 6.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 7Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 7.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 8Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation Single Use, Sterile , Endotracheal Tube, Plain - Size 8.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Cuff- Size 4Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting The Shape Of Product , Endotracheal Tube, Cuff- Size 4.5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting , Endotracheal Tube, Cuff - Size 5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting Theshape Of Product , Endotracheal Tube, Cuff - Size 6Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 6.5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 7Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting The Shape Of Product , Endotracheal Tube, Cuff- Size 7.5 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 8 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 8.5 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack – Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 9 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use Curved Shaped Blister Pack – Suiting The Shape Of Product , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 24) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 28) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 32) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Polypropylene Nonabsorbable Synthetic Surgical Mesh 7.5 Cmx 15 Cm Soft To Feel Fast Edges,Slightly Stretchbonding. , Polypropylene Nonabsorbable Synthetic Surgical Mesh 15 Cmx 15 Cm Soft To Feel Fast Edges,Slightly Stretchbonding. , Sterilized Umbilical Cotton Tape Width 3 Mm, Length 75 Cm Should Conform To Schedule F(Iii) Of Drug And Cosmetic Act 1940 , Bone Wax Sterilised , Pressure Monitoring Line / High Pressure Extension Line • Suitable For High Pressure Monitoring And For Connection Between Syringe Infusion Pump And Patient • Male Luer Lock At One End And Female Luer Lock At Other End ; Should Fit All Standard Equipment. Luer Lock Connectors Should Provide Secure Fitting. • Pressure Upto 800 Psi • Length 200 Cm • Sterile , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) • Option To Use One Or Two Catheters Simultaneously • Bellow Chamber With Capacity 800 Ml • Bellow Unit With Connector • Graduated Bellow • Connecting Tube With Clamp And “Y”Connector • Curved Needle / Trocar With Catheter • Multiperforated Catheter / Radon Drain With Radio Opaque Line • Catheter 16 Fg , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) • Option To Use One Or Two Catheters Simultaneously • Bellow Chamber With Capacity 800 Ml • Bellow Unit With Connector • Graduated Bellow • Connecting Tube With Clamp And “Y”Connector • Curved Needle / Trocar With Catheter • Multiperforated Catheter / Radon Drain With Radio Opaque Line • Catheter18 Fg , Sterile Catheter, Single Use, For Urinary Drainage(Foley Balloon Catheter), 2 Way, Size 14 • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For A Traumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30+-1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Ballon Capacity Should Be Mentioned As Per Is 11497 • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is 11497 , • Nelaton Catherer Size14fg Distal End Is Close And Proximal End Has Female Colour Code Connector • Soft, Kink Resistant Medical Grade Pvc Tube • Length:40 Cm • Individually Packed In Poly And Sterile , Ecg Electrode •Reliable Trace, •High Conductivity,• Easy To Handle , Vascular Catheter 16G/5Fr, Double Lumen Length 40Cm.Usfda/ Four Digit Notified Ce Approved, Should Have Two Guide Wire 45Cm & 80Cm Or More (Logline Iv.) Peel-Away Sheath Glide Thru 5Fr*10 Cm, Guide Wire Nitinol 80 Cm, Guide Wire Nitinol 45 Cm Introducer Needle 21 G *7 Cm, Syringe - 10 Ml Tuer-Lock, Skin Protectant Prep Pad, Second Site Adjustable Hub, Measuring Tape, 5 Fr Pressure Injectable Picc Line With Blue Flex Tip 40 Cm, Dressing Statloock Stabilization Device (Suture Less) , Vascular Catheter With Metal Guide Wire, 4Fr Single Lumen, Distalvalve, Saline Flush Only Size 45Cm Or More Usfda/ Four Digit Notified Ce Approved (Logline Iv.) Internal Stylet, Statlock Stabilization Device (Suture Less), Introducer Needle, Micro Introducer With Vessel Dilator, Guide Wire- 50 Cm Nitinol, Safety Scalpel,Suture Wing, End Cap , Vascular Catheter With Metal Guide Wire 3Fr Single Lumen,Micro Introducer,Contrast Media Compatible, Size 45Cm Or More (Logline Iv.) Usfda/ Four Digit Notified Ce Approved Syringe 12 Ml,Internal Stylet,Measuring Tape,Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G, Micro Introducer With Vessel Dilator,Guide Wire-50 Cm Nitinol,Needle Introducer 21 G, Safety Scalpel, End Cap , Vascular Catheter With Metal Guide Wire 5Fr Double Lumen, Introducer Safety Piv Catheter20g, 45Cm Or More (Logline Iv.) Usfda/ Four Digit Notified Ce Approved Syringe 12 Ml, Internal Stylet, Measuring Tape, Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G,Micro Introducer With Vessel Dilator,Guide Wire-50 Cm Nitinol,Needle Introducer 21 G,Safety Scalpel, End Cap , Eyelid Occlusion Dressing Should Have Width Of 3.5 To 4.0 Cm & Length Of 9.5 To 10.0Cm, Dual Zonel With Central Zone As Transparent Window, Material-100% Polyurethane Clear Film Layer, Made Up Of Polyester Non-Woven Fabric, Latex Free, Solvent Based Acrylic Adhesive, A Set Of 2 Sterile Dressing , Ce Certified. , Speech Prosthesis For Laryngectomy (Indwelling Lowresistance Silicon Voice Prosthesis Varied Diameter With Varied Length Should Have Blue Teflon Valve Seet For Primary And Secondary Insertion Along With Inserting Tools And Cleaning Accessories) 22.5Fr (6 Mm) , Speech Prosthesis For Laryngectomy (Indwelling Lowresistance Silicon Voice Prosthesis Varied Diameter With Varied Length Should Have Blue Teflon Valve Seet For Primary And Secondary Insertion Along With Inserting Tools And Cleaning Accessories) 22.5Fr (8 Mm) , Adult Conventional Single Water Trap Adult Conventional Single Water Trap (Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification , Adult Ventilator Circuit Single Limb Portable Adult Ventilator Circuit With Universal Single Limb. Must Be Complete Kit With Main Circuit Hose, Exhalation Valve Manifold, Aerosol Hose, Patient Elbow Connector, Proximal Airway Pressure Line, Exhalation Valve Line, And Humidifier Limb. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Angiography Wire Ptfe Guidewire In 0.035,0.038 In Regular Length [Nrs-244] , Glaucoma Drainage Implant (Valved) With Silicon Tubeadult Size (184Mm2)Include Free Size L..Regular 2.Small 3.Large , Triple Layered Antimicrobial Form Dressing For Burn Wounds With Silver Sulphate, Silver Content 1.2Mg/Cm2 With Active Release Of Silver Upto 7 Days With Soft Silicon Atraumatic Wound Contact Layer For Painless Dressing Change. Product Should Be Ce/Usfda Certified Size 20X20 Cm +15% Deviation In Size Will Be Acceptable. , Syphilisantibody (Rapid) Detection Kits 1. The Assay Should Be Based On Rapid Chromatographic Immunoassay For Qualitative Detection Of Antibodies (Lgg, Lga & Lgm) To Tp In Serum, Plasma & Whole Blood. 2. The Assay Should Utilize Recombinant Treponemal Antigens I.E. Tp15, Tpl7, Tp47 Against Syphilis. 3. The Assay Should Be In Card Format. 4. Adequate Documents Detailing The Principle Components, Bio- Safety Methodologies, Validity Criteria, Interpretation Of Results, Performance Characteristics Storage Conditions, Limitation Of Assays Manufacturing & Expiry Dates Should Be Provides With Each Kit. 5. The Kit Should Have Approval Of The Statutory Authority In Its Country Of Origin. 6. In Case Of Imported Kits It Should Be Registered And Licensed Under The Provisions Of Drugs & Cosmetics Act And Rules And/Or Medical Devices Rules 2017 In India. 7. In Case Of Indigenous Manufacturers Should Be Licensed Under The Provisions Of Drugs & Cosmetics Act And Rules And Or Medical Devices Rules 2017 Issued By The Competent Authority Defined Under Drugs And Cosmetics Act, 1940. 8. The Kit Should Have Minimum Shelf- Life Of 5/6Th Or 12 Months (Whichever Is More) At The Port Of Discharge Of Consignees. 9. Read Result Time Should Not Be More Than 20 Minutes. 10. Assay Should Have Sensitivity 100% & Specificity 99 %Or More With Documentary Evidence. 11. The Storage & Transport Temperature Of The Kit Should Be 2-30°C. 12. The Pack Size Should Not Be More Than 50 Tests Wherein Each Test Is Individually , Multistix Test Strips 1. Urine Strip Use For Semi Quantitative Analysis For 10 Parameters: (A) Glucose (B) Protein (C) Ph (D) Specific Gravity (E) Nitrite (F) Urobilinogen (G) Blood (H) Ketone (I) Leucocytes (J) Bilirubin 2. Interpretation Of The Result Should Be Both By Visual Reading By Comparing With Color Scale On Label And Strip Analyser. 3. Strip Should Be Ce Certified And Ivd Approved. 4. It Should Read The Result Within 60 Second. 5. It Should Have Instruction Manual (Hindi And English) For Detail Information Regarding Use Of Strip And Principle Of Various Parameters. 6. It Should Have Following Sensitivity /Reference Values:- Glucose : <25Mg/Dl Protein< 15Mg/Dl Ph : 5.5-7.0 Specific Gravity : 1.015-1.025 Nitrite : Negative :Positive Urobilinogen : < 17 ? Mol/L Blood : Negative : Positive Ketone : <2.0 Mg/Dl Leucocytes : <10 Leu/?L Bilirubin : <0.2Mg/Dle 7. Strip Should Be Stable At +2°C To +30°C. 8. It Should Have Pack Size 1×100 Strip. 9. Shelf Life Of The Strip Must Be One Year From The Date Of Supply With Open Vial Stability Of Strip Must Be At Least Three Months. 10. Firm/Manufacturer Should Have Its Manufacturing & R&D Unit In India.