| 1 | Comprehensive maintenance including renewal/replacement of defective parts of electrically operated 2x1lifts =02 lifts (KONE Make) each of 08 passengers capacity with selective controls catering for six floors including ground floor, installed at B-7 in Residential Area at DEAL Dehradun complete all as specified and directed including any other spare parts required other than mentioned under Ser item 6 to 18, 20 to 31, 33 & 34 below shall to be deemed included in quoted rates complete, all as specified and directed. |
| 2 | Comprehensive maintenance including renewal/replacement of defective parts of electrically operated 1x1Freight Elevator=01 freight Elevator (Jhonson Make) each of 1000 Kgscapacity with selective controls catering for one floors including ground floor, installed at CERSBuilding New Technical area at DEAL Dehradun complete all as specified and directed, including any other spare parts required other than mentioned under Ser item 6 to 18, 20 to 31, 33 & 34 below shall to be deemed included in quoted rates complete, all as specified and directed. |
| 3 | Comprehensive maintenance including renewal/replacement of defective parts of electrically operated 2x1=2 lifts with manufacturing year 2016, (OTIS make) each of 08 passengers capacity with selective controls catering for six floors including ground floor, installed at D-6 Block Residential building at DEAL Dehradun complete all as specified and directed including any other spare parts required other than mentioned under Ser item 6 to 18, 20 to 31, 33 & 34 below shall to be deemed included in quoted rates complete, all as specified and directed.. |
| 4 | Comprehensive maintenance including renewal/replacement of defective parts of electrically operated 1x1=1 lift with manufacturing year 2008(OTIS make) of 09 passengers or (safe working load) 612 Kg capacity with selective controls catering for five floors including ground floor, installed at SATCOM building DEAL Dehradun complete all as specified and directed including any other spare parts required other than mentioned under Ser item 6 to 18, 20 to 31, 33 & 34 below shall to be deemed included in quoted rates complete, all as specified and directed. |
| 5 | Note for 1to 4:- (i) Contractor need toliaise with lift OEM and visit lift sites with OEM company authorised representative to check the complete lift machine roomto identify the performance of lift, comprehensive safety inspection including load testing, emergency stop functionality and other critical safety checks.(ii) After Joint visit , If any repair maintenancerequired in the lift or any spare part then contractor should do the repair maintenance of the lift through OEM supplied part only in complete prospective and specification. (ii) After necessary Checking by OEM, contractor must produce the MoU with lift OEM for eleven month comprehensive maintenance of parts that are available with OEMand submit the ink sign copy to the Engr-in-charge within 30 days of acceptance of tender.(iv) Safety parameter and smooth functioning of lift should be checked by the lift OEM as per MoU at the beginning of tender & consolidated report to besubmitted to Engr-in-charge. (v) During joint inspection, if any suggestion or specificmaintenance related point is suggested by OEM for enhanced lift operation to be submitted to Engineer-in-Charge by contractor. |
| 6 | Supply only Power Contactor 10 to 25 Amps rating,3 Ph110 V ) suitable for lift of make Otis/Kone/Jhonson complete all as specified and directed. |
| 7 | Supply only relay cards For control panel suitable for (OTIS/Kone/Johnson make) lift complete all as specified and directed |
| 8 | Supplyonly in replacement of full length Infra Red Door sensorsuitable for lift(make - Otis/Kone/Jhonson)complete all as specified and directed |
| 9 | Supplyonly main controller card / motherboard suitablefor OTIS/Kone/Jhonson make lift complete all as specified and directed |
| 10 | Supplyonly SMPS power supply 5A, 12/24 V DC or suitable Capacity for OTIS/Kone/Johnson make lift complete all as specified and directed |
| 11 | Supplyonly floor indicator 7 segment 12/24 Volt DC suitablefor OTIS/Kone/Johnson make lift complete all as specified and directed |
| 12 | Supplyonly limit switch Suitablefor OTIS/Kone/Jhonson make lift complete all as specified and directed |
| 13 | Supplyonly Reed switch suitsblefor OTIS/Kone/Johnsonmake lift complete all as specified and directed |
| 14 | Supplyonly stop switch suitable forfor OTIS/Kone/Johnson make lift complete all as specified and directed |
| 15 | Supplyonly Emergency alarm for OTIS/Kone/Johnson make lift complete all as specified and directed |
| 16 | Supplyonly travelling cable12 core (0.50 sqmm) for OTIS/Kone make lift complete all as specified and directed |
| 17 | Supplyonly main rope(13mm) make Usha martinfor OTIS/kone/Johnson make lift complete all as specified and directed |
| 18 | Supplyonly door drive (make- Yaskawa/Fuji)for OTIS/Kone /Johnson make lift complete all as specified and directed |
| 19 | Supply & fixing of electronic drive in elevator control panel (Main VVVF drive) relevant for 15 HP electric motor complete with key board built in or detachable for proper control & command inputs and proper analysis of errors & trouble shooting by an engineer for proper functioning of OTIS/Kone/Johnson /Thaison/ECE/Jhonson Make lift complete all as sprcified and directed. |
| 20 | Supply only ARD with battery setsuitable for OTIS/Kone/Johnson /Thaison/ECE/Jhonson lift complete all as specified and directed. |
| 21 | Supply only ARD instruction plate assembly with nut bolt and hardware for lift of make Otis/Kone/johnson complete all as specified and directed. |
| 22 | Supplyonly door shoe suitable for OTIS/Kone/Johnson make lift complete all as specified and directed |
| 23 | Supplyonly door safety lock suitablefor OTIS/Kone/Johnsonmake lift complete all as specified and directed |
| 24 | Supplyonly thimble suitablefor OTIS/ECE/KONE/Johnson make lift complete all as specified and directed |
| 25 | Supplyonly landing operating panel (LOP) for OTIS/Kone/Johnson make lift complete all as specified and directed |
| 26 | Supplyonly car operating panel (COP) for OTIS/Kone/Johnson make lift complete all as specified and directed |
| 27 | Supplyonly serial card suitablefor OTIS/Kone/Johnsonmake lift complete all as specified and directed |
| 28 | Supplyonly door lock roller suitable for OTIS/Kone/johnson make lift complete all as specified and directed |
| 29 | Supplyonly Lift fan suitable size as per existing suitable for OTIS/Kone/Johnson make lift complete all as specified and directed |
| 30 | Supply only battery 7.5/ 12AH suitable for OTIS/Kone/Johnson make lift complete all as specified and directed |
| 31 | Supply only break linner suitable for OTIS/Kone/Johnsonmake lift complete all as specified and directed |
| 32 | Supply and replace LED recrssed ceiling light 5w square/round oras per existing type in lift complete all as specified and directed |
| 33 | Supply and replace Rubber mat 5 mm thick in lift siutable for car flooring incl necessary fixing arrangment complete all as specfied and directed |
| 34 | Material and labour for disconnceting of electric motor of 15/20 HP capacity from Lift, taking motor to workshop for rewinding /repair opening of motor, taking out burnt winding wire and rewinding with super emameled copper winding wire of suitable size/gauge and turns as per compatibility of capacity of motor including proper insulation, heat varnishing, drying with proper heat, reassembling electric motor, and taking motor to lift machine room connceting with lift and testing complete all as specified and directed |
| 35 | Supply and fix in repalacement of Car door 700 to 800 mm centre openingor siuable size as per existing with car header and door formator 1.2 mm 18 gauge304 grade stainless steel door panel in moon rock finish of Otis/ kone/Johnsonwithheader and door with lock complete functional accesoories incliding infrared door curtain sensor/ detector consisting of the emitter and receiver, power supplybox, flexible cables relay output 1 A, 230 VAC/2A 30 VDC, operating temperature 20 degree to 85 fegree, 154 beams, reponse time 61 ms, highest beam 1860 mm, lowest beam 25mm and protection distance 0 to 5 m Incl necessary accesories for fixing sensorscompleteall as specified and directed by Engineer-in-charge. Make : as Per MOU submitted. |
| 36 | Supply and labour for replacement of landing door 700 to 800 mm size or as per existing size centre opening automatic 1.2 mm 18 gauge 304 grade stainless steel door panelin moon rock finish lift of otis/konewith header and door lock completeformator incl functional accessories complete all as specified and directed.Make : as Per MOU submitted. |
| 37 | Material and labour for replacement header for car door as per existing size with rollers, cam car door motor,formator, lock contacts by dismantaling of header andassembling new heafer with necessary joining materials nut bolts washers, welding, rivetingetc required complete all as specified and directed |
| 38 | Material and labour forpainting of machinineries including all motors gear box LT electric panel board incl connected accessories etc , installed at lift room , painting with super emamelled Painttwo coats of approved quality with spray gunafter prepatation of surfaces complete all as specified and directed |
| 39 | Material and labour for Cleaing of lift pit and dewatring/lifting of water inside of lift pit by using pum set complete all as specified and directed |
| 40 | Material and labour for numbering on each floor of respective building lift (as G floor, 1 st floor,2 nd floor and so on) each floor wall depending on the level of building served by the lift and writing details on a PVC board specifying JE E/M, AGE E/M, operators details and fixing on top of inside/outside of the lift car at ground floor Note : (i) Each Job is considered for all the levels of the building served & directed by Engineer-in-charge |
| 41 | M&L for painting of lift car incl doors with two coats of super emameled paint of approved quality with spray gun after preparation of surfaces complete all as specified and directed by Engineer-In-charge. |