| 1 | Earth work excavation in all classes of soil such as hard stiff clay, light black cotton, shalles, muram except hard rockincluding all charges etc., complete as per SS20 B. |
| 2 | Supplying and filling the foundations and basement with approved quality of well Gravel in layers of 15cm thick well rammed and consolidated as per standard specification. |
| 3 | P.C.C 1:4:8 mix using 40mm metal including cost and conveyance of all materials to site with all leads of pure water for curing and all labour charges and all other incidental charges etc complete |
| 4 | Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification |
| 5 | Brick workin CM 1:5 mix using country bricks includingcost and conveyance of all materials to site with all leads of pure water for curing and all labour charges and all other incidental charges etc complete |
| 6 | Centering and shuttering for soffits of all RCC workincludingcost and conveyance of all materials to site and all labour charges and all other incidental charges etc complete |
| 7 | Plain Surface |
| 8 | Slab |
| 9 | Supply and fabrication of Steelincludingcost and conveyance of all materials to site and all labour charges and all other incidental charges etc complete |
| 10 | R.C.C 1:11/2:3 mix using 20mm metalincludingcost and conveyance of all materials to site with all leads of pure water for curing and all labour charges and all other incidental charges etc complete |
| 11 | Plastering in CM 1:4 mix 12mm thick includingcost and conveyance of all materials to site with all leads of pure water for curing and all labour charges and all other incidental charges etc complete |
| 12 | Special ceiling plastering in CM 1:3, 10 mm thickincludingcost and conveyance of all materials to site with all leads of pure water for curing and all labour charges and all other incidental charges etc complete |
| 13 | Drilling of 150mm dia deep bore well in hard rock area to required depthincluding cost and all labour charges and all other incidental charges etc complete. |
| 14 | Supply and Fixing of 180mm OD 6KSC PVC Pipe for casing Pipe for Medium depth in to drilled bore well.cers complete complying with standard specifications |
| 15 | Supply and delivery submersible pump set with ISI mark IS 8034/200215lpm x 150m head including all cost and conveyance of materials to site and all labour charges etc, complete. |
| 16 | Supply and delivery of fully automatic 1.5 HPair break auto tranforrmer panel board with single phasing preventory with ammeter voltmeter with auto restart facility including all cost and conveyance of materials to site and all labour charges etc, complete. |
| 17 | Supply and Deleveryof 1000 Litre capacity PVC Tank with ISI mark including cost and conveyance of all materials etc. complete. |
| 18 | Supply of Steel Door to (1.00*2.00)m sizeincluding cost and all labour charges and all other incidental charges etc complete. |
| 19 | Painting with extrier emulsion Paint Two coats with approved colourincluding cost andconveyance of all materials to siteand all labour charges and all other incidental charges etc complete |
| 20 | Painting in two coats with Ready mixed Enamel paint for New steel work including cost andconveyance of all materials to siteand all labour charges and all other incidental charges etc complete |
| 21 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 22 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 23 | Supplying and fixing over the floors best quality of scratch ceramic tiles of 30 c.m x 30c.m x 6mm sizeof approved colour laying with cement mortor 1:3 mix pointing the joints with colour pigments etc.Complete. |
| 24 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitablePVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheetcover with TW switch box and 5A FT switch with continuous earth wire connection of 14 SWG TC wire for makinggood of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) SD 24 |
| 25 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable SD 38PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mmTW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush typeswitch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion withsuitable colour for concealed PVC plug point SD 38 |
| 26 | Supplying and delivery ofPVC Insulated and sheathed 2.5 Sq mm3 core Flat type copper cable confirming to IS 694 /1990 including cost of materials etc., complete |
| 27 | Towards labour charges for the erection of 1.5HP submersible pumpset in borewell/open well including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps pressure gauges upto the exterior wall of pump room and erection of panel board consiting of TPICN switches starter, volmeter, ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc, complete and testing the pumpset and trail run for 10 days |
| 28 | Supplying and delivery of40mm HDPE PIPES FOR SUB-MERSIBLE PUMP IN BORE WELL Class-5 including cost of materials etc., complete |
| 29 | Supplying and delivery ofNylon Rope for Bore-well including cost of materials etc., complete |
| 30 | Dadooing walls withGlazed tiles of sizes 300mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. |