Upgradation Of Dfo Complex Anantnag.-- 1 Engagement of Labour for placing existing water storage tank on slab complete. 2 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 3 Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded 4 P/A French spirit polishing, one or more coats on old work 5 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete 6 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on new work. 7 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer 8 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:4:8 or Leaner mix 9 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.For thickness of tiles 10 mm to 25 mm 10 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. 11 CEMENT PLASTER (IN COARSE SAND)6mm cement plaster 1:4 12 Providing and fixing Ist quality ceramic Glazed Wall Tiles conforming to IS : 13753 ofminiumum thickness 6 mm of approved makein all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Chargein skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. Size of Tile 450 x 300 mm.(including cost of all material, leads, lifts and carriages etc upto site of work complete). 13 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Imported wood 14 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : 35mm thickimported wood 15 Providing and fixing of 3 mm thick glass panes (Weight not less than 10 kgs/Sam) including cost of wooden beadings 16 Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm 17 CEMENT PLASTER (IN COARSE SAND)12mm cement plaster 1:4 18 Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete 19 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including all carriages complete job 20 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. completeSize of Tile =300x300mm 21 Providing and fixing of Hardware Fixtures toShutters of Doors & Windows:Aluminium make 22 Tower Bolts 150mm 23 Handles 250mm 24 L-Drop 300mm 25 Construction of wardrobe2 deep wardrobes cabin with 19 mm thick plywood and 10 mm thick plywood on back side ,plywood shutters fixed with denmica of std make on expopsed surfaceswith all fittings and fixtureslike handles, locks , catchers etc including carriage of materialall complete as per the directions of incharge engineer at site (Face area to be measured) 26 Providing and fixing wash basin with pedestalWhite Vitreous China Wash basin size 550x400 mmw ith all necessary fittings like waste pipe , hooks etc( sample to be got approved by Incharge engineer at site) including removal of existing washbasin 27 Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm 28 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes fixing of all fixtures and fittings like unions tee, plugs etc testing of joints complete as per direction of Engineer-in-charge.PN-16 pipe , 50mm OD 29 PN-16 pipe 25mm OD 30 Providing and fixing CP Brasswall mixer 2 in 1 of standard quality(Parryware,hindware,cera) or equivalent make as approved by Engineer in charge. 31 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 32 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 33 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing 34 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete:10 liter (full flush) capacity-white 35 Providing and fixing C.P Brass Soap Caseincluding Soap 36 Providing and fixing C.P Brass Towel rod 37 Providing and fixing PVC soil, waste and vent pipes75mm dia 38 Providing and fixing PVC soil, waste and vent pipes100mm dia 39 Providing and fixing of window catch eye cabin hook for windows 40 Septic Tank 41 Earth work in excavation by Mechanical means in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5 Mt. In width or 10 SqMts on plan) including dressing of sides and ramming of bottoms, lift upt 1.5 Mtr. Including getting out excavated soil and disposal of surplus soil as directed and lead up to 50 Mtrs 42 Providing and laying hand packed stone soling in foundation under floors etc. inel ramming, watering and ensolidating complete cost and carriages of all materials involved upto site of work complete. 43 Providing and laying in position cement concrete of specified grade M-7.5 excluding the cost of centering and shuttering-All work at all levels in: 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) including cost and carriage of all materials involved upto site of work complete. 44 Brick work with F.P.S (non modular) bricks of class designation 75 in foundation and Plinthin 1:6 mix (1 cement: 6 coarse sand) including carriage of all materials from approved sources upto site of work complete. 45 12mm cement plaster of 1:4 ratio 46 Providing and laying in position specified grade of reinforced cement concrete includingcuring but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 47 Steel reinforcement for R.C.C. work including straightening, cutting. bending, placing in position and binding all complete above plinth level TMT steel bar 48 Centering/Shuttering including removal of formwork complete job for suspended floors 49 Providing and fixing PVC soil, waste and vent pipes100mm dia 50 Soakage Pit 51 Earth work in excavation by Mechanical means in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5 Mt. In width or 10 SqMts on plan) including dressing of sides and ramming of bottoms, lift upt 1.5 Mtr. Including getting out excavated soil and disposal of surplus soil as directed and lead up to 50 Mtrs 52 Providing and laying hand packed stone soling in foundation under floors etc. inel ramming, watering and ensolidating complete cost and carriages of all materials involved upto site of work complete.Avg. Lift 2.5m 53 Providing and laying in position specified grade of reinforced cement concrete includingcuring but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 54 Steel reinforcement for R.C.C. work including straightening, cutting. bending, placing in position and binding all complete above plinth level TMT steel bar 55 Centering/Shuttering including removal of formwork complete job for suspended floors 56 Providing and fixing PVC soil, waste and vent pipes100mm dia 57 Path 58 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, lead upto50 meter and lift upto 1.5m, as directed by Engineer-in-Charge.All kinds of soil : 59 Providing and laying hand packed stone soling in foundation under floors etc. incl carriages of all materials involved upto site of work complete.Avg. Lift 2.5m 60 Providing and laying in position cement concrete of specified grade M-7.5 excluding the cost of centering and shuttering-All work at all levels in: 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) including cost and carriage of all materials involved upto site of work complete. 61 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. 62 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including all carriages complete job 63 Providing and laying of pre cast RCC rings for Recharge pitof dia 32 and height 8 including earth work in execution including slab, all carriages all complete as per directions 64 Court Room 65 Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded 66 Providing and fixing of 19mm plywood for Platform including cost of 2mm dunmica,cost of all fixtures and fasteners complete job. 67 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 68 Electric part 69 Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC Insulated flexible stranded copper conductor wires in recessed or surface medlum class PVC condult, with 240V 6A modular switch, modular plate and earthing the point with 1.5 sq. mm FRLS PVC Insulated copper conductor single core cable, etc. as required. (Havells/Polycab/Anchor/ Finolex/KEI/RR/Rhein/Paraflex or equivalent make) excl. cost of condult. 70 Wiring for light/power plug polnts (15/16A heating points) with 2x4 sq mm FRLS PVC Insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC Insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circult). (Havells/ Polycab/ Anchor/Finolex/KEI/RR/Rheln/Paraflex or equivalent) excl. cost of conduit 71 Supplying and fixing of suitable size Gl box with modular plate and modular 12 cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/SSK/Anchor/ ABB/Schnelder or equivalent) 72 Supplying and fixing of suitable size Gl box with modular plate and modular 07 cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/SSK/ Anchor/ABB/Schneider or eq.) 73 Supplying and fixing of modular sockets/Indicators/switches on existing modular plate and switch box, Incl. connections, etc. as required. (Havells/SSK/Anchor/ABB/Schneider or equivalent) 1.3 pin 5A-10A socket. 74 II. Indicator 75 Point wiring for SA-10A socket out lets (computer points) with 2x2.5 sq mm 120 (P+N)FRLS PVC Insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing), (Maximum two points shall be connected on one circuit). (Havells/ Polycab/ Anchor/Finolex/KEI/RR/Rhein/Paraflex or equivalent) excl. cost of conduit 76 Supply, installation, testing and commissioning of 12 Watt LED recessed/ 32 mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India, Operating temperature -10°C to +45°C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the Intending department. (Havells/Philips/Crompton/Jaguar/Wlpro/Halonix). Commercial series 77 Supply, Installation, testing and commissioning of 1 star 1200 mm sweep celling 03 fans of Havells / Crompton Greaves/Bajaj/ Usha/Anchor (Sample to be got approved), Incl. cost of extension of Gl rod (if required) and making of necessary connections. 78 Supply and fixing of two module stepped electronic fan regulator on the 03 existing modular plate switch box, Incl. connections but excluding modular plate etc. as reqd. 79 Supply, installation, testing and commissioning of 200-250 mm sweep shutter 04 type exhaust fans, Incl. making of space in walls/ windows as per site and necessary connections. (Havells/ Anchor/Usha/BajaJ/Crompton). 80 Supply, installation, testing and commissioning of 400 mm sweep wall fans of 01 Havells/Crompton, Incl. making of necessary connections. 81 Supply, Installation, testing and commissioning of 10 Watt (2 feet long) LED celling/wall mounted batten (tube lights) having aluminum housing, minimum 80lm/w, average life 50000 hours. The Job Includes replacement warranty of fixture If damaged/ burnt out what so ever reason for a period of one year reckoned from the date of successful commissioning/ handing over of site to the Intending department 82 Supplying and fixing of modular blanking plates on existing modular plate and switch box, excluding modular plate as required 83 Wiring for sub mains along with earth wire in FRLS PVC Insulated G60/1100 volt grade flexible stranded copper conductor wires In recessed or surface conduiting system, excl. cost of condults(Havells/ Polycab/ Finolex/ Anchor/KEI/RR/Rheln/Paraflex or equivalent). 84 2 x 1.5 sq.mm + 1x 1.5 sq. mm earth wire (Inverter/solar circult) 85 2 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire (Lighting circult) 86 2x 6 sq.mm + 1x 6 sq. mm earth wire (Lighting sub main) 87 2 x 10 sq.mm + 1x 6 sq. mm earth wire (Heating sub main) 88 Supply and fixing of 16 way Double door surface/ recess mounting, Horizontal type, 240 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral Ink, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer 89 Supply, installation, testing and commissioning of 5-32A single pole rating 20 240/415V, 10 КА C curve MCB of Legrand/Havells/L&T suitable for Inductive load in the MCB distribution board complete with necessary connections. 90 Supply, installation, testing and commissioning of 40 A DP rating 240V, 10 KAC curve MCB of Legrand/ Havells/ L&T suitable for Inductive load In the MCB distribution board complete with necessary connections. 91 Supply, installation, testing and commissioning of 63A DP rating 240, 10 KA Ccurve MCB of Legrand/ Havells/ L&T suitable for Inductive load In the MCB distribution board complete with necessary connections. 92 Supply and fixing of ceiling rose, incl. base block and necessary connections. 93 Providing of chemical earthing as per IS standards by way of digging 8 feet plt 01 then embedding 3 mtr. Long Gl earthing electrode, 80 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2 dia. Full threaded brass nut and bolts and washers, refilling the pit with chemical compound. 94 Supply, Installation, testing and commissioning of wall/floor mounted compartmentalized, main distribution panels, fabricated out of 16 gauge sheet steel, dust protected, painted, incl. earth terminal with all necessary accessories with internal wiring as required. The panel is to be provided with the following adjustable type controlling/ protection switch gear devices:1.NORMAL INCOMING125A DP MCB 10КА 01 по.200A SP&N bus bar AL. Strips 01 setDigital meter and phase Indicators 01 set.2. Generator INCOMER63A change over switch 01 no.100A SP&N bus bar AL. Strips 01 setDigital meter and phase Indicators 01 set.3.INVERTER/SOLAR INCOMER40A DP MCB 10КА 01 по.100A P&N bus bar AL. Strips 01 setDigital meter and phase indicators 01 set.OUTGOING63A DP MCB 10KA 02 по.0A DP MCB 10KA 02 по32A DP MCB 10KA 01 поThe contractor has to submit the test certificate of main switch gear. 95 Supply, laying, connecting and commissioning of 50 sq. mm 2 core PVC 30 Insulated and PVC sheathed/XLPE power cable of 1.1 KV grade Aluminum LT cable, incl. cost of required al. thimbles duly crimped. 96 Supply and fixing of 25 mm dla./25 mm wide Medium grade PVC conduit 100 including its allied accessories like bends and concealed deeps, etc. for laying of wires, recessed in RCC slab/walls Incl. resurfacing of walls or fixed with clips and rowel plugs complete. 97 Supply and installation of 32A Industrial/modular plug/socket with 32A DP MCB 04 for ACs