Tender For Supply, Erection Testing, Commisioning Of 33 Kv Line And Other Works For Receiving Station Gmc Associate Hospital Rajouri. Under The Jurisdiction Sub-Transmission Division (Jpdcl) Kalakote, kalakote-Jammu And Kashmir

Jammu And Kashmir Power Development Department has published Tender For Supply, Erection Testing, Commisioning Of 33 Kv Line And Other Works For Receiving Station Gmc Associate Hospital Rajouri. Under The Jurisdiction Sub-Transmission Division (Jpdcl) Kalakote. Submission Date for this Tender is 08-10-2025. Transmission Line Tenders in kalakote Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

51326171
Corrigendum : Tender For Supply, Erection Testing, Commisioning Of 33 Kv Line And Other Works For Receiving Station Gmc Associate Hospital Rajouri. Under The Jurisdiction Sub-Transmission Division (Jpdcl) Kalakote
Tender
Indian
Jammu And Kashmir
Kalakote
08-10-2025

Tender Details

SUPPLY, ERECTION TESTING, COMMISIONING OF 33 KV LINE AND OTHER WORKS FOR RECEIVING STATION GMC ASSOCIATE HOSPITAL RAJOURI. UNDER THE JURISDICTION SUB-TRANSMISSION DIVISION (JPDCL) KALAKOTE-- 1 COST FOR 33 KV LINE BAY OF SINGLE BUS SCHEME 2 SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type)with allied accessories and heavy duty pad clamps. 4 33kV C&R Panel along withO/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port 5 33 kV Isolator With Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 6 33 kV Isolator Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 7 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 8 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) 9 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 10 33 kV Polymer Post Insulator36kV,170kV Impulse, creepage distance 1224m 11 GI STEEL STRUCTURES 12 Galvanised Steel Structures 13 Galvanised Nuts & Bolts 14 SITC OF CONTROL CABLES 15 Supply, Laying, Testing & Commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 16 Supply, Laying, Testing & Commissioning of 04Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 17 Supply, Laying, Testing & Commissioning of 02 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 18 Lugs, Ferrules etc. 19 SITC OF CONDUCTOR & HARDWARE 20 Providing & Fixing 200 mm² ACSR Conductor Panther 21 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 22 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 23 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 24 GI Earth wire 7/4.00 mm sq. 25 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 26 COST FOR 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME 27 SUB‐STATION MAIN EQUIPMENT 28 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 29 33 kV Isolator Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 30 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 31 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 32 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 33 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 34 GI STEEL STRUCTURES 35 Galvanised Steel Structures 36 Galvanised Nuts & Bolts 37 SITC OF CONTROL CABLES 38 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 39 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 40 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 41 Lugs, Ferrules etc. 42 SITC OF CONDUCTOR & HARDWARE 43 Providing & Fixing 200 mm² ACSR Conductor Panther 44 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 45 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 46 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 47 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 48 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 49 SITC OF COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATIONS 50 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 51 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 52 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 6.3 MVA Power Transformer 53 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 54 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 55 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 56 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 57 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 58 SITC OF 33 kV LINE 59 11 Mtr. Long Pole (ST-410- SP56) 60 GI V cross-arm with top Bracket including clamps 61 GI Channel X-Arm including clamps and braces 62 GI Wire SSS 63 100 mm² AL59 Aluminium Claded Steel Conductor (Covered Conductor) 64 Tension Clamps with bail & IPC (Insulation Piercing Conductors) 65 Alignment Ties 66 IPC (Insulation Piercing Conductors) from bare to CC (Covered Conductor) 67 IPC from CC to CC Connection 68 IPC with Aluminium bail for Earthing 69 Mid Span Joint 70 33 kV Isolator without Earthing Blade (36kV, 2500A, Outdoor, 3 poles, 25 kA) 71 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 72 33kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting 73 Galvanized Nuts and Bolts. 74 Danger Plates with Clamps 75 Anti-Climbing Device with Clamps 76 Earthing Complete by GI Pipe 40 mm or GI Rod20mm, 3 mtr long through GI Strip. 77 Red Oxide 78 Aluminium Paint 79 Cement bottoming for 11 Mtr Long ST Pole, 0.78 Cum/Pole 80 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-09-2025 date extension Date 08-10-2025

Key Value

Document Fees
INR 3000 /-
EMD
INR 280400.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail