Tender For Special Repair To P-556, T668 And T-669 At Af Stn Srinagar.; 1 Building Work 2 Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed. 3 Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed. 4 M&L for brick work with sub-class `B bricks (using old size bricks), straight or curved on plan exceeding 6m mean radius built in CM 1:6, Complete all as specified and directed. 5 M&L for brick work with sub class B bricks (using old size bricks) straight or curved on plan to any radius in half brick thick wall radius, built in CM 1:4, complete all as specified and directed. 6 M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finishing even and smooth without using extra cement, complete all as specified and directed. 7 M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finishing even and smooth without using extra cement, complete all as specified and directed. (WPC shall be measured and paid separately) complete all as specified and directed 8 Supply only water proofing compound of approved make, complete all as specified and directed. 9 Preparation of new plastered surfaces o wall and applying two coats of distemper oil emulsion including thin layer (1mm thick) of wall care putty and priming coat, complete all as specified and directed. 10 Preparation of new plastered surfaces of walls andapplying two coats of anti-fungal exterior emulsion paint over a coat of cement primer including thin layer of wall care putty, complete all as specified and directed. 11 Complete removal of existing treatment from wall surfaces and applying two coats of oil bound distemper of approved colour including applying 1mm thick wall care putty for making the surface even and smooth and filling the uneven and small holes and making the edges of plaster properly by plaster of paris preparatory to distempering including preparation of surface by washing rubbing down and stopping of distempered surfaces, complete all as specified and directed. 12 Complete removal of existing treatment on plastered surfaces of walls including washing, rubbing down and stopping of old treatment including thin layer of wall care putty and applying two coats of anti fungal exterior emulsion paint over a coat of cement primer, complete all as specified and directed. 13 Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) n exc. 1.5 Sqm and credited to the contractor, complete all as specified and directedNote: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. 14 Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n exc 4.0 Sqm and credited to the contractor, complete all as specified and directedNote: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. 15 Taking down shutters of any description size of shutter exc 1 Sqm but n.exc 2 Sqm and removing from site complete all as specified and directed. 16 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying and fixing in opening, complete all as specified and directed. 17 S&F 30mm thick Factory made Solid Panel PVC Door Shutter (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed. 18 S&F pressed steel frame for doors with one rebates size of frame 105x60 mm including necessary fixing lungs hinges lock strike plate etc. including PCC, 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in back filling of pressed steel frame, complete all as specified and directed. 19 S&F pressed steel frame for doors with one rebates size of frame 125x60 mm including necessary fixing lungs hinges lock strike plate etc. including PCC, 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in back filling of pressed steel frame, complete all as specified and directed. 20 S&F 35mm thick 2nd class hardwood, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), complete all as specified and directed. 21 S&F 35mm thick 2nd class hardwood plain framed, panelled shutter (two panel), factory made, with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. 22 S&F 150mm size Aluminium handles, cast type, anodised, complete all as specified and directed. 23 S&F 150mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. 24 S&F 100mm long medium weight, cold rolled mild steel Butt hinges, complete all as specified and directed.. 25 S&F 100mm size Aluminium handles, cast type, anodised, complete all as specified and directed. 26 S&F 100mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. 27 S&F 250mm mild steel helical door spring rat tail type including collar plate and welding if required or otherwise fixed with screw on wooden/ mild steel frames, complete all as specified and directed. 28 Preparation of new wood and wood based surfaces of any description exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. 29 S&F 250mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) & fixed clips of sheet, cast or extruded section & fixed bolts & sliding bolts of extruded section or cast aluminium alloy, complete all as specified and directed. 30 S&F aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. 31 M&L for Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, 150 mm handles 2 Nos in each door shutter, 100 mm hinges-03 Nos, 150mm tower bolt -02 nos in each shutter anodised aluminium snap beading, screws etc.complete all as specified and as directed 32 S&F anodised aluminium for powder coating of any colour (Thickness or powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified 33 S&F 4.8mm thick sheet glass ordinary quality and glazing with aluminium glazing clips and rubber neosprine gasket in square or rectangular in section n exc 0.5 Sqm in each pane, complete all as specified and directed. 34 S&F 5mm thick pvc sheet as in doors, of any colour, shape, size and design fixed on aluminium frame work including all necessary fittings and fixtures and necessary taping, complete all as per manufactures instructions, complete all as specified and directed. 35 S&F for 140mm length floor door stopper of aluminium alloy body and tounge, anodised with harde drawn steel spring fixed in floor, complete all as specified and as directed. 36 S&F aluminium powder coated aluminium window having three track (minimum thickness of powder coating 50 micron) with aluminium section 92mm X 31.75mm (Weight bottom section 1.070 kg/m, top section 0.933 kg/m, shutter section 40mm X 18mm (weight of handle section 0.417 kg/m) interlock 0.547 kg/rm mounted on bearing to slide on tracks plain anodized in approved shade including supply andfixing of 5mm thick sun / heat reflected glass and wire mesh, PVC track gasket, EPDM rubber gasket on glass of weather tightening along with locks, handle including sealing gap with marble surfaces with silicon sealants making it water proof in all manner etc. including taking down old window any type complete all as specified and directed. 37 S&F for powder coated aluminium grill (Thickness or powder coating not less than 50 micron) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved powder coated aluminium standard section around the opening, complete all as specified and directed. 38 Dismantling of timber scantlings 40 sqcm and over in section, in any position unframed work, complete all as specified and directed. 39 M&L for Second Class hard wood and scantling timber framed and fixed wrought complete all as specified and directed. 40 Dismantlingof boarding,any description, fixed in any position withnails in existing wooden slab, complete all as specified and directed. 41 S&F 20mm thick second class hard wood, clean sawnplanks, width n exc. 20cm fixed in existing wooden eves board, complete all as specified and directed. 42 Preparation of old painted wood surfaces and wood based materials of any description over 10cm width or girth and applying one coat synthetic enamel paint, complete all as specified and directed. 43 M&L for French polishing on surfaces of any description width or girth including cleaning and preparing the surface including a coat of wood filler on old wooden works with one or more coats, complete all as specified and directed. 44 M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings conforming to Fe-410- W (GdeE-250) quality B (exclusive or steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, complete all as specified and directed. 45 M&L for structural steel work as in truss, rafter purling, made out of angle / Hollow pipe / tube section including jointing cleats, plates flat iron, gusset plates, rails, braces etc. conforming to Fe 410-W (gde-E-250) Quality, confirming to IS-1161-1979 of grade St-240 complete all as specified and as directed. 46 Preparation of new steel surface and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide primer, complete all as specified and directed. 47 Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not etc. 50m and making good surface, work in soft/loose soil, complete all as specified and directed. 48 M&L for plain cement concrete, 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in posts, walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars (including caps and bases) including necessary form work, complete all as specified and directed. 49 S&F in repairs 20mm dia stainless steel drapery curtain rods including brackets, end finials (Latoo), for curtain rails fancy decorative type and fix with brass screws to walls approved quality etc., complete all as specified and directed. 50 Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and directed. 51 M & L forAnodised aluminium snap grid size 600mm x600mm frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specifiedcomplete all as specified and directed 52 S&F 6mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / aluminium framework with screwsincluding putty to receive finishes, complete all as specified and directed. 53 S&F in repairs 6mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber /GI / aluminium framework with screws to ceiling flat or sloping, complete all as specified and directed. 54 Preparation of old plaster/ AC sheet / Gypsum board surfaces of ceiling including cornices and applying one coats of oil bound distemper colour / tint, complete all as specified and directed. (5.1+39.7+8.3) 55 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. 56 S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. 57 S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. 58 S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating, complete all as specified and directed. 59 S&F 0.63 mm thick Galvanised, corrugated mild steel but except sheeting with two corrugations side lap, with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating, complete all as specified and directed. 60 S&F 0.63mm thick Galvanised, Plain mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating, complete all as specified and directed. 61 Preparing new zinc (or galvanised) surfaces to receive painting of any description over 10cm width or girth, by coating with mordant solution including washing and cleaning, etc. steel and iron surfaces and applying two coats of synthetic enamel paint over one coat red oxide primer, complete all as specified and directed. 62 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc., complete all as specified and directed. 63 M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. 64 M&L for 20-25mm thick machine cut Kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing / grinding and polishing upto mirror finish complete over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed. 65 Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. 66 M&L for Glazed ceramic tile 450x300x06-7mm thick on vertical surfaces such as wall, dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10mm thick screed bed in CM 1:4, complete all as specified and directed. 67 M&L for Glazed ceramic tile 300 x 200 x 06-7mm thick on vertical surfaces such aswall, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick screed bed in CM 1:4, complete all as specified and directed. 68 M&L for Non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. =1225.8+223.37 69 Demolition ofcement concrete (unreinforced)in ground floor and pavings n exc 15cm thickness (below or above ground level), complete all as specified and as directed. 70 M&L for 25mm thick plain cement concrete, 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub base of floor finish even and rough to receive further floor finishes (tile/kota stone/ marble ), complete all as specified and directed. 71 M&L for Light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed. 72 M&L for Light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat CM 1:4, complete all as specified and directed. 73 M&L for 75mm thick plain cement concrete, 1:3:6, type C-2(using 40mm graded crushed stone aggregate) as in plinth protection, finished even and smooth without extra cement, complete all as specified and directed. 74 M& L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm gradedstone aggregate) insub base complete all as specified and directed. 75 M&L for chequered cement concrete tiles size 300 mm x 300 mm x 22-25mm thick with grey cement and pigment , rubber moulded glossy finish, ISI marked, coloured, set jointed and pointed in neat cement slurry over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed. 76 M&L for plain cement concrete, 1:4:8, Type D-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed. 77 M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand Complete all as specified and direction. 78 S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm Ball PTMT valves, high pressure, with polythene float and flynut including dismantling existing water tank and removing from site, complete all as specified and directed. 79 Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed. 80 Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed. 81 S&F for 15mm bore tubes, medium grade, galvanised, with all fitting, ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc.) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified and directed. 82 S&F for 20mm bore tubes, medium grade, galvanised, with all fitting, ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc.) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified and directed. 83 Refixing old GI pipe 15mm bore & connections in new or old position to walls and ceiling or laid in floor, complete all as specified and directed. 84 Refixing old GI pipe 20mm bore & connections in new or old position to walls and ceiling or laid in floor, complete all as specified and directed. 85 M&L for Lagging to 20mm bore pipes used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh including applying with brushing neat cement slurry with 3 kg of cement per Sqm complete, complete all as specified and directed. 86 S&F in repairs 10 litre capacity PVC valveless, Syphonic action type, flushing cistern low level, white with inlet ball valve, float and handle including brackets and PVC flush pipe etc., complete all as specified and directed. 87 S&F in repairs Vitreous China wash down water closet pan (pedestal pattern),white (excluding flushing cistern ) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, PVC cover sheet in same colour etc., complete all as specified and directed. 88 S&F in repairs vitreous china wash basin white flat back,size550x400 mm, with & including 32mm dia PVCwaste pipe and waste coupling with & including angle iron brackets of suitable size & length or erecting stand etc., complete all as specified and directed. 89 S&F in repair vitreous china bowl urinal flat back size of 465x355x265mm white with grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screw, pointing aroug urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe grating and union for discharge pipe all as spd 90 S&F in repairs 125mm dia CP grating doom with waste hole, complete all as specified and directed. 91 S&F in repairs 100mm / 75mm stainless steel grating, complete all as specified and directed . 92 S&F in repairs 15mm bore hot and cold water mixer with swan neck for WHB chromium plated quarter turn screwed down, including necessary fittings, complete all as specified and directed. 93 S&F in repair long body bib cock fancy type 15 mm dia chromium plated with crutch or buterfly handle,serewed down,screwed for MS pipe or for brass ferrule complete all as specified and directed. 94 S&F in repairs 15mm bore Stop valve / angle valve, cast copper alloy, chromium plated, fancy type, screwed down high pressure with capstan head, complete all as specified and directed. 95 S&F 6mm thick glass corner shelves, fancy type, 225x225mm size, complete all asspecified and directed. 96 S&F in repairs soap dish, brass chromium plated any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed. 97 S&F in repairs 32 mm dia bore PVC flexible pipe for wash hand basin, complete all as specified and directed. 98 S&F 50mm dia PVC pipe low density (LDPE) of pressure 6kg/sqcm fixed to wall or laid in floor as waste pipe, complete all as specified and directed. 99 S&F in repairs 15mm size PVC connections with PTMT nuts of length 600mm, complete all as specified and directed. 100 S&F in repair600mm long towel rail of PTMT fixed with and including chromium plated brass screw and wooden / plastic cleats(minimum weight 190gms), complete all as specified and directed. 101 S&F in repairs for 600mm x 450mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed 102 Dismantling ofPVC drain pipes, 75/100 mm dia including all fitting, jointed with rubber ring and taking out from trenches / walls, complete all as specified and directed. 103 S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floors, complete all as specified and directed . 104 S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floors, complete all as specified and directed . 105 S&F 100/75mm outlet PVC (SWR) floor trap with chromium plated grating including Jointing to waste pipe and fixed in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), complete all as specified and directed. 106 S&F 110mm size PVC (SWR) bends of any radius fitted with oval access doors, complete all as specified. 107 S&F 75mm size PVC (SWR) bends of any radius fitted with oval access doors, complete all as specified. 108 S&F 110mm bore PVC (SWR) vent cowl, complete all as specified and directed. 109 S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door, complete all as specified and directed. 110 S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door, complete all as specified and directed. 111 M&L for DWCPE (SN8) 165 (OD)/150(ID) mm diameter Pipes laid on 150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional. layed with 150mm thick bedding 1:4:8 type D-2 and depth 0.70mto 1.65 maverage complete all as specified and directed. 112 Supply, installation, testing & commissioning HDPE Septic tank of size 2000 mm dia and 2250 mm height, with 115 mm dia inlet pipe and supply & fix 160 mm dia PVC(SWR) pipe of length 2 m for connecting septic tank to soakage Pit & 50 mm dia vent pipe, fixed in position and connection with inlet, outlet & vent pipe as per manufacturer instruction complete all as specified and directedMake:- Sintex Model No CCST-500-01 or equivalent model No of make Comfert polymers, or make approved by GE.Note:- Excavation, Earthwork and returning filling with sand will be measured & paid separately. 113 M&L for Soakage well in soft / loose soil, size 3.50m dia and 4.00m depth (100 users), PCC 1:3:6 in foundation, 150 mm thick, wells of Honey combed brick work with CM 1:4 with using sub class ‘B’ old size brick, PCC bend using 1:2:4 concrete at every 1.00m Height, 115mm thickness of brick work should be increased at every 0.75m depth and filling brick bats in the wall upto 2.00m height and provide 100mm thick RCC slab of M-25 grade concrete including intercepting / Screen chamber, complete all as specified in TD-CE/AF/STD-15/2000 Sheet No 1/2 and 2/2 dated 05 Jan 2000, complete all as specified and directed.Note:-1. Including form work, Excavation, Returning filling, Remove excavation material with site clearance. 2 Demolition of old soakage well and returning filling of excavated soil.3 Returning filling in old soakage well will be measured & paid separately to refer items. 114 Internal Electric Work 115 Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point includingfixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made asper conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surfaceand finishing the surfaces as per existingcomplete all as specified and directed. 116 M & L for Concealed Point wiring for Light/ceiling/exhaust fan point controlled by one switch on Independent boardwith 1.5 sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded coppercable confirming to IS:694(2010) using approved colour code for phase and neutralas per IS code drawn through non metallic PVC rigidconcealed conduitheavy mechanical stress (HMS) grade inaccordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thickand minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc with all accessories suitable formodular/conventionaltype fitment,provision for fixing of modular flush boxes of appropriate size and dimensionsfor fixing ofpiano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 1.5 sqmm multi stranded copper conductor cable (green color) as continous earthlead wire connected to common earth and earth dollycomplete all as specified and directed by Engr-in-Charge. Note: (i) For concealed point wiring cutting chases for conduit shall be measured and paid seperately (ii) For sinking boxes cutting chases for conduit shall be measured and paid seperately 117 Description all as per item No 116 abovebutfor one belll/Buzzer point controlled by one bell push 5 Amp on the same board with other switches or independent. 118 Description all as per ser item No 116 but for 05 amp socket outlets point controlled by one switch on Independent board complete all as specified and directed. 119 Description all as per ser item No 116 but for 05 amp socket outlets point controlled by one switch on Independent board complete all as specified and directed. 120 Description all as per ser item No 116 but for 15 amp socket outlets point controlled by one switch on Independent socket outletusing 2.5sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded coppercable confirming to IS:694(2010) using approved colour codeforphase andneutral as per IS code drawn through non metallic PVC rigid surface conduitheavy mechanical stress (HMS) grade inaccordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thickand minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc fixed concealedwith all accessories suitable formodular type fitment,provision for fixing of modular flush boxes of appropriate size and dimensionsfor fixing ofpiano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 2.5 sqmm multi stranded copper conductor cable (green color) as continous earthlead wire connected to common earth and earth dollycomplete all as specified and directed by Engr-in-Charge. 121 M & L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-charge 122 Description all as per item no.08 above for exc 10 cm but not exc 20 cm girth complete all as specified and directed by Engr-in-charge 123 M & L for module cover plate with frame as per site requirement for following module 124 (a) 2 module 125 (b) 3 module 126 (c) 4 module 127 (d) 6 module 128 (e) 8 module 129 M & L for modular metal Flush box as per site requirement 130 (a) 1/2 module 131 (b) 3 module 132 (c) 4 module 133 (e) 6 module 134 (f)8 module 135 M & L for modular switch 1 way 6 Amp,230 volts ,1 Module complete all as specified and as directed by Engr-in-charge. 136 M & L for modular Bell Push Switch1 way 6 Amp,230 volts, 1 Module complete all as specified and as directed by Engr-in-charge. 137 M & L for Modular Switch 1 way 16/20 Amp,230 volts, 1 Module complete all as specified and as directed by Engr-in-charge. 138 M &L for Modular Socket 6A, 230 volts, 2/3 Pin universal 2 module complete all as specified and as directed by Engr-in-charge. 139 M &L for Modular Socket 16A, 230 volts,2/3 Pin combined 2 module complete all as specified and as directed by Engr-in-charge. 140 M &L for Modular fan step regulator 100 watt 2 module complete all as specified and as directed by Engr-in-charge. 141 S&F Ceiling rose, surface bakelite 65 x 50 mm, 3 terminals fixed on PVC Round Block, complete all as specified and directed by Engr-in-Charge. 142 Supply and fix Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete. 143 S&F energy efficient LEDintegrated batten type luminairessuitable for wall or ceiling mounting with built in LED Chip & integral LED driver 20 watt,Aluminiumchannel housing & Polycarbonate diffuser of length 1200 mm (approx.),Color temperature 6500 K or as directed,Luminaire efficacy not less 100 lm/W with all accessories, fixing arrangement internally pre-wired, making all connection using 1.5 sqmm copper conductor multistarnd PVC insulatedcable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge. 144 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5 sqmm copper conductor multistarnd PVC insulatedcable from ceiling rose to fitting drawn through PVC flexible conduit complete all as specified and directed. 145 Supply and fixing LED Bulk Headtype with high out put , 10 watt ,220 V AC,Color temperature 6500 K or as directed,Lumens 1000 lm with all accessories ,IP 65 protection dust and water resistant ,surge protection up to 2.5kV, PC opal high efficiency diffuser ,LM 80 tested made die cast aluminium housing with complete assembly, suitable for surface/wall mountedwith driver holder including connecting up using 1.5 sqmm copper conductor multistarnd PVC insulatedcable of suitable sizecomplete all as specified and directed. 146 Supply & Fixing LED luminaire 600mm x 600mm,35/36 Watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexiable copper conductor cases of suitable size complete all as specified and directed by Engr-in Charge. 147 S&F electric water heater, storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 Ltr, BEE 5 star rated complete with all accessories such as saftey valve, thermostate, NRV, connection piece etc. complete all as specified and directed by EIC. 148 S&F exhaust fan, made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 300mm. Complete all as specified and directed . 149 S & F ceiling fan 5 star complete with blades, down roads, electronic regulator and accessories, single phase 230V, 50 Hz, 1200 mm sweep. Min air dalivery 210 CFM with service value 6.00 BEE. five star rated with brushless direct current motor(BLDC). complete with twine core flexible copper conductor. Make : Havells/Bajaj/Usha 150 Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size 200 amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification 151 M & L for distribution board (DB), double door type, as per IEC 61439-3 made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 4 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 125 Amps, 16KA, 2 neutral bar and 2earth bar IP 54 protection,cable ties for cable management(Fully insulated busbar and shrouded neutral bars),reversible door for IP 43 & IP 54 ,flush mounted to wall complete all as specified and directed.Note : Rates are inclusive for flush(Concealed ) mounting of DB and MCCB 160Amp TPN is included under respected items. 152 Supply and fixing 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed. 153 Supply and fixing 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 40- 63 AMP , in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed. 154 Supply , installation testing & commissioning of maintenance free compound based electrode Chemicalearthing with following Specificationsa) Type=Copper Bonde Rodb)Material=Low carbon steel core (SAE 1018)c) Length=3000mmd) Dia of rod=17mme) Coating Thickness=250 micronsf) Terminal=U Bolt Clamp or equivalentg) Tolrence in length=± 20mmh) Tolrence in diameter=±1.0mmi) Torence in thickness=±0.03mmj) Current with stand=10 KA for 1.0 sec and 25 KA peakk) Frequency =50 Hzl) Back fill compound=BARON ELECTRODITE (ROHS Certification)m) PIT Cover=FRP (or) EPCCn) Granular material resistance=0.001 Ohmo) Mixer ratio with cement=3:1NOTE:- Electrode top terminal shall be sealed permanently packed with conductive concrete and CU bonded strip taken out be terminated on earth test point and equipped terminalMAKE:-Ashlok(Zeus)/Baron/Macmate/SG 155 M&L Sub main wiring usingPVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded coppercable confirming to IS:694(2010) using approved colour code for phase and neutralas per IS code drawn through non metallic PVC rigidconduitheavy mechanical stress (HMS) grade inaccordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and external dia as underbut shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc with all accessoriescomplete all asspecified and as directed by Engr-in-chargeof the following sizes of cables as under . 156 (a) Using two single corePVC insulatedFRLSH cable 4.0 sqmm copper conductor multi stranded ( Phase and neutral) and4.0 sqmm copper conductor PVC insulatedFRLSHcable as earth wiredrawing in and including concealed PVC conduitnot less than 2.00 mm thick ,25 mm outer dia(ISI marked)with all accessoriesNote :2 runs of 4.0 sqmm copper cable & 1 run of 4.0 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit 157 (b) Using two single corePVC insulatedFRLSH cable 6.00 sqmm copper conductor multi stranded ( Phase and neutral) and6 sqmm copper conductor PVC insulatedFRLSHcable as earth wiredrawing in and including concealed PVC conduitnot less than 2.00 mm thick ,25 mm outer dia(ISI marked)with all accessoriesNote :2 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit 158 External Electric Work 159 Dismantling of old UNSV OH LT transmission line and any number of conductors of any size / any span a complete all as specified and directed. 160 Taking down old unserviceable XLPE LT cables of any size and type complete all as specified and directed by Engr-in-Charge. 161 Dismantling of old concrete poles any size all as specified and directed. 162 M&L forSupply, laying, jointing and testing, LT cable 1100 volts grade of cross sectional area 185 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cablescomplete all as specified and as directed. (Note : MS clamps with nuts, bolts washer etc shall not be measured separately under relevant items) 163 Item as above at Srl No 150 but size of cable 120 Sqmm X3.5 core 164 Item as above at Srl No 150 but size of cable 95 Sqmm X3.5 core 165 Item as above at Srl No 150 but size of cable 25 Sqmm X 4 core 166 Supply and fix in of steel tubular swaged pole complete with cast iron base plate final taper plug, bolts, nuts & screws as specified type 410 SP-22 (9.0 mtr long) including two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed. 167 M&L for cement concrete 1:3:6 type C2 using 40 mm graded as in foundation filling and mass concrete complete all as specified. 168 M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) for coping including form work etc complete all as specified and directed. 169 Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed. 170 Taking down street light fitting, flood light fittings 30/ 60/ 90/ 120/ 250 watts any type any wattage from Street tubular pole/PCC Poles/Perimter wall poles dismantling and checking out serviceability of part/decarburising at the end of joint of PVC/XLPE cable and fixtures connector cable, circuit such as drivers, MCPCB etc. replacement of unserviceable parts with new parts including soldering with existing circuit board, reassembling and refixing in position including conneting, testing complete all as specified and directed.(all UNSV accessories shall be replaced under respective items).Connected T&P/Manpower/safety toolsi.e ladder, crane, Elcn, helper, gloves, safety belt,helmet etc will be provided by the contractor. 171 Supply and fixing of LED street light fitting 90 Watts, IP 66, having pressure die cast alumnium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-66 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. 172 Excavation in trenches n.exc1.5 M wideand n.exc 1.5 M depth and getting outfor laying of underground cable etcin any type of soil complete all as specified and directed Engineer-in-Charge. 173 Returning, filling in, including spreading,levelling watering and well ramming in layers n.exc 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge. 174 Removing of excavated soil to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed Engineer-in-Charge. 175 Supply and Laying of sub class B bricks , locally available in trenches for protection of underground cable complete all as specified. 176 M&L for dry & clean sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of sand after laying the cable and punned the same up 18 cm complete all as specified and directed by Engineer- in-Charge.Note:- Only punned thickness shall be measured and paid. 177 Supply and fixing junction box IP 65 with metric knockouts for cable entry up to 25 Sqmm, Box size 205x255x112 mm with terminals including MCB SP 6A and fixed on pole with MS clamps including two coat of Al paint over one coat of red oxide primer complete all as specified and directed. 178 M & L for painting of steel tubular LT poles with two coats of aluminium paint including painting to cross arms and clamps etc including preparation of surfaces by scrubing and cleaning with wire brush all as directed. 179 M & L for marking of pole serial number with black luminous words on luminous yellow round sticker as per sample complete as per directed & specified. 180 S&F in replacement of GI pipe of size 50 mm dia light grade for housing/protection to the LT cables complete all as specified & directed by Engr-in-Charge. 181 S&F in replacement of street light bracket made out of light grade GI Pipe32 mm nominal bore, 1.2 metre long tilted to 30 degree angle on 4 metre length along with flat iron clamp of 40 x 4 mm size 750 mm long duly drilled made to shape the bracket complete with nut bolt and washers including applying 2 coats of aluminium paint over a coat of red oxide primerall as specified and as directed by Engr-in-charge. 182 S&F in replacement of MCB SP 6A-32A, 240V, 10kA breaking capacity complete all as specified and directed by Engr-in-charge. 183 M&L for repairing broken coping of pole foundation by using PCC (1:2:4) type B1 by using 20 mm graded aggregate as in pole base upto the height of 50 cm from the ground level and 600mm diaincluding necessary form work and painting with oil bound distemper over a coat of primer and finishing the surfaces all as specified and as directed by Engr-in-charge. 184 Material and labour for feeder pillar board kiosk type, LT (415 Volts, 50 Hz, 3 Phase, 4 wire supply) floor mounted, factory assembled, outdoor type weather and vermin proof (Protection class IP-54) made out and 3.15mm thick MS sheet CRCA sheet aluminiumbus bar of 200 Amps capacity with hingedopening, rubber lining , lockingarrangement, painted externally and internally with two coats of synthetic enemel grey paint first quality ovar a coat of red oxide primer including the provision of the following :-(b)MCCB4 Pole , 200 Amps, rupturing capacity 16 kA, 440 Volts, adjustable type - 01 Nos as outgoing(e) Indicator LED phase lamps 03 Nos (R, Y, B) - 01 Set.(f)Volt meter 0-500 Volts with selector switch - 01 No(g)Ammeter 0 - 300A with selector switch with CTs - 01 No.(h)Platform for the feeder pillar board with PCC 1:2:4, 15 cm thick in foundation , brick (sub class B) work in CM 1:6, rendering in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.The platform shall be 450mm high above the ground level. 185 Material and labour for earthing complete with galavanised steel earth plate electrode of size 60mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below gound level with top edge of the earth plate not less than 1.5 m below normal gound level connected to galvanised steel earth strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galavanised iron/steel and conneted to main control board as directed and including proivison of concrete pit in PCC (1:2:4) type B1 pre cost RCC earth pit cover reinforced with 8 mm dia TMT bars @ 150mmc/c of size 54cmx54cmx8cm with two handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galavanised steel tubing (med grade) for watering. Charcoal 250 Kg and salt 200 Kg in alternate layers, 40mm bore galavanised steel tubing light grade for protection of earth lead connection including necessary excavation and earth work and testing complete all as shown on electrical plate No 3 of SSR Part-I.Note : Earth strip and protection pipe upto 7.5m is included in the unit rate of this item. Contractor shall quotehis rate accordingly. 186 Supply, installation and commissioning and testing of LT panel cubical type suitable for 415 volts 3 phase 4 wire, 50Hz AC supply system , floor mounted, out door type factory fabricated duly powder coated inside and outsideouter cover made out of 3.15mm thick CRCA sheet , internal cover and partition made out of 2mm thick CRCA sheet with angle iron 50mmx50mmx6mm covered from all side with front and back openableweather proof including suitable size copper cable and embeded in brickwork in CM 1;4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts,bolts, and washers etc complete all as specified and directed by Engineer-in-Charge. INCOMING: (a) MCCB 4 pole 400 Amps 50 KA,415 vols AC with adjustable thermal and adjustable magnetic setting-01 Nos (b) Aluminium Bus bar 200 Amps TPN -04 Nos. (c) Digital volt meter 0-500 volts with selector switch-01 nos. (d)Digital Amp Meter 0-500 Amps with selector switch& CT -01 Nos. Indicator lamp LED Type (R,Y,B) complete with bakalite fuse fitting-01 set. (f) Onload change over switch 160 Amps with suitable handle for operating. OUTGOING:- (a) MCCB 4 pole 250 Amps 25 KA ,415 volts AC-02 Nos . (b)160 Amps 25 KA, 415 Volts AC-02 Nos (c )100 Amps 25 KA, 415 Volts AC-02 Nos 187 M&L Sub main wiring usingPVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded coppercable confirming to IS:694(2010) using approved colour code for phase and neutralas per IS code drawn through non metallic PVC rigidconduitheavy mechanical stress (HMS) grade inaccordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and external dia as underbut shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc with all accessoriescomplete all asspecified and as directed by Engr-in-chargeof the following sizes of cables as under . 188 (a) Using two single corePVC insulatedFRLSH cable 2.5 sqmm copper conductor multi stranded ( Phase and neutral) and2.5 sqmm copper conductor PVC insulatedFRLSHcable as earth wiredrawing in and including concealed PVC conduitnot less than 2.00 mm thick ,25 mm outer dia(ISI marked)with all accessoriesNote :2 runs of 2.5 sqmm copper cable & 1 run of 4.0 sqmm copper cable