| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-10-2025 | Corrigendum2 | Date | 18-10-2025 |
| 2 | 01-10-2025 | Corrigendum | BOQ | 17-10-2025 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 3 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 4 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 5 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. |
| 6 | Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core in trenches,along the wallincluding necessary connection and providing cable lugs as required includingdisconnection/taking down of existing unsvcable all as specified. |
| 7 | -Ditto- all as per item No 06 above here-in-before but 70 Sqmm 3.5 Core -do- |
| 8 | -Ditto- all as per item No 06 above here-in-before but 50 Sqmm 3.5 Core -do- |
| 9 | -Ditto- all as per item No 06 above here-in-before but 35 Sqmm 3.5 Core -do- |
| 10 | -Ditto- all as per item No 06 above here-in-before but 25 Sqmm 3.5 Core -do- |
| 11 | -Ditto- all as per item No 06 above here-in-before but 16 Sqmm 4 Core -do- |
| 12 | -Ditto- all as per item No 06 above here-in-before but 10 Sqmm 4 Core -do- |
| 13 | M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge.. |
| 14 | M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/ PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints. |
| 15 | -Ditto- all as per item No 14 here-in-before but 3.5/4 core 70 Sqmm to 120 Sqmm size -do- |
| 16 | S& F in replacement of GI pipe medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protectionincluding necessary fittings , clamps for supports, etc all as directed by Engineer in charge. |
| 17 | Supply and fixPower Capacitors of Rating 20 KVAR 415 Voltin repairs Naturally air cooled Double dielectric heavy duty, MPP type440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified. |
| 18 | All as per item No 17 above but Power Capacitors of Rating 15 KVAR 415 Volt |
| 19 | All as per item No 17 above but Power Capacitors of Rating 10 KVAR 415 Volt |
| 20 | All as per item No 17 above but Power Capacitors of Rating 7.5 KVAR 415 Volt |
| 21 | All as per item No 17 above but Power Capacitors of Rating 5 KVAR 415 Volt |
| 22 | M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge. |
| 23 | M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge. |
| 24 | Equipment and labour for servicing of ACB including drawing/taking out from LT Panel, cleaning the Contacts,checking the breaker accessories, replacing the burnt out control wiring, burnt fuse units, old unsversiable spring units for proper function and carrying out ratio testby applying primary injection all for LT ACB 630 Amps to 800 Amps and refixing the breaker in position and testing all as directed by Engineer in Chare at siteNote : The Contractor shall brought all T & P and testing equipments. |
| 25 | Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw,display. Make : L & T / SCHNIDER/ ABB/ C&S |
| 26 | S & Fin repair LT 3 Phase Digital ammeter with built in selector switch and connecting including CT & necessary wiring if required complete all as specified. |
| 27 | S & F in repair Digiital 3 phase 440 Volts VAF PF (Voltage, Current, Frequency & Power Factor) meter with built in selector switch and connecting including CT & necessary wiring if required complete all as directed. |
| 28 | M & Lfor testing of APFC panel for proper functioning in manual & auto mode, including re-wiring theburnt outwires, replacing the wiring ducts/casing Capping, fuse units and cleaningand testing complete all as specified and directed. |
| 29 | Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating,Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system complete all as specified and directed. |
| 30 | All as per item No 29 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32. Make : L & T or equivalent from Schnider Electric, ABB/ C&S |
| 31 | All as per item No 29 above but Contactor Three Pole 415 volts40Amps AC 3 RatingConforming to Type- MNX - 40. Make : L & T or equivalent from Schnider Electric, ABB/ C&S |
| 32 | All as per item No 29 above but Contactor Three Pole 415 volts50 Amps AC 3 Rating Conforming to Type-MNX - 50. Make : L & T or equivalent from Schnider Electric, ABB/ C&S |
| 33 | All as per item No 29 above but Contactor Three Pole 415 volts70 Amps AC 3 Rating Conforming to Type- MNX - 70. Make : L & T or equivalent from Schnider Electric, ABB/ C&S |
| 34 | All as per item No 29 above but Contactor Three Pole 415 volts110 Amps rating Conforming to Type- MNX - 110. Make : L & T or equivalent from Schnider Electric, ABB/ C&S |
| 35 | S & F in repair MCCB 400 Amps, 36 KA Triple Pole 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed. |
| 36 | All as per item No 35 above but MCCB 250 Amps, 25 kA Triple Pole 415 Volts |
| 37 | All as per item No 35 above but MCCB 200 Amps, 25 kA Triple Pole 415 Volts |
| 38 | All as per item No 35 above but MCCB 125 Amps, 16 kA Triple Pole 415 Volts |
| 39 | All as per item No 35 above but MCCB 100 Amps, 16 kA Triple Pole 415 Volts |
| 40 | All as per item No 35 above but MCCB 63 Amps, 16 kA Four Pole 415 Volts |
| 41 | All as per item No 35 above but MCCB 40 Amps, 16 kA Four Pole 415 Volts |
| 42 | Supply and fix in repair add on Blocks suitable forPower contactors of range 25 Amps to 140 amps (MNX 25 to MNX 140 including making addition/Alternation to existing Wiring/circuit system all of Make- L&Tor equivalent from Schnider Electric/ABB/ C&S |
| 43 | Supply and Fix in repairs Push buttons complete of colour red/ green with NO/NC elements, operating on 230 V, 50Hz, AC supply complete all as specified and directed. |
| 44 | Supply and Fix in repairs Selector Switch 3 Positionsuitable for LT panels, operating on 230 V, 50Hz, AC supply complete all as specified and directed. |
| 45 | S & F in repairs LED based complete(R Y B ) for mounting on LT panel, operating on 230 V, 50Hz, AC supply complete all as specified and directed. |
| 46 | S & F in repair Closing coil 415 V/230 V for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed. |
| 47 | S & Fin repair Shunt Release 415 V/230 for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed. |
| 48 | M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as specified and directed. |
| 49 | Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers andconnectors after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LEDwill be measured and paid separately]. |
| 50 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel /National/Sintax |
| 51 | M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using computerised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site.Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately.(ii) Cable joint will be measured and paid seperetely.(iii) Additional lenth of cable required at site for jointing will be measured and paid seperately. |
| 52 | M&L in repairs of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification. |
| 53 | S&F in repairs GI strip size 32 x 6 mmall as directed including welding brazing and taking down of old strips as required at site |
| 54 | M & L spray painting inside, outside complete tothe LT panel boards outdoor type of size not exceeding 2.0 Mtrwidth 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. |
| 55 | Supply and fix in repairs stainless steel cable glands required for cable entry in Panel of size from 10 sqmm to 50 sqmm etc. complete all as specified and directed. |
| 56 | -Ditto- all as per item No 55 above here-in-before but for 70 sqmm to 120 sqmm complete all as specified and directed. |
| 57 | -Ditto- all as per item No 55 above here-in-before but for 150 sqmm to 300 sqmm complete all as specified and directed. |
| 58 | Supply and fix in repairs alluminium cable lugs of size 16 sqmm to 50 sqmm for cable connection etc complete all as specified and directed. |
| 59 | Supply only CTC/ CRC solution spray to remove out the moisture and corrosion content from electrical equipement complete all as specified and directed. |
| 60 | Supply only cotton waste industrial type for cleaning of electrical equipment , Panel board etc complete all as specified and directed. |
| 61 | M&Lin repairs for 24 Hrs240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE |
| 62 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO. |
| 63 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO. |
| 64 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60Amp suitable for single phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T/Indo Asian |
| 65 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 415 V, 10 - 60Amp suitable for three phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T/Indo Asian |
| 66 | M&L for testing of old earthing using calibrated earth tester & submitting result to Engr -in -charge all as directed.Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried outone day before the testing & the cost of the same shall deemed included in unit rate quoted. |
| 67 | M&L for taking down old unsv and supply & lay 3Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts,all For interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as directed. Make :- POLYCAB / PLAZA / Havells. |
| 68 | Suply and fix New generation , post-top LED light 15W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 50MM dia in the PCC for cable entry the fittingwith nut bolts,washer shall conform to cat No-RUBYMINIPT 15WLED830 PSYMT OPC of Havells equivalent from Philips, bajaj/CG. |
| 69 | A Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 70 | S&F in repair of building Security lightfitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make : Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS. |
| 71 | S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge |
| 72 | Supply & Fix 8/9watts LED Bollard Garden light fittings with efficient high outputLED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation0.3 Meter x 0.3 Meter x 0.3Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, including mounting arrangementupto 2.00 mtr height with medium grade GI tubing of suitable dia 50mm alongwith MS angle bracket/framed covers, clamps complete all as specified and directed. Make - Havells or Equivalent from Bajaj/ Cromp[ton |
| 73 | M & L in repairs for servicing ofCentrifugal pump setof capacity 25 HP by opening end covers, greasing the bearings, replacing worn out nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush and painting one coat ofsynthetic enamel paint, including writing/marking in 1\" size letters SM & MES No. for the following capacity of pumps:- |
| 74 | All as per Item No 73.00 above but Pump set 15 HP |
| 75 | All as per Item No 73.00 above butPump set 10 HP |
| 76 | All as per Item No 73.00 above but Pump set 5HP |
| 77 | Supply and fix in repairs/replacement of old unserviceable Cast iron tank coverwith MS strip /flat iron framework with all necessary fixing and locking arrangement nuts,bolts all as per BMC standards any required alteration to the tank for fixing ofnew CI covers all as specified and directed by the Engineer -in-Chief ofsizes:- 508mm dia. (weight of tank cover not less than 12 Kgs) |
| 78 | M&L for rewinding of electric motor 25 HP 3 phase 50 Hz 415 volt of following capacities complete all as directed and specified as under: (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc.(b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing onload. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA.(e) Replacement of winding terminal plate with brass stus,/ nut, bolt washer. |
| 79 | All as per Item No 78.00 For Motor 20 HP Cap |
| 80 | All as per Item No 78.00 For Motor 15 HP Cap |
| 81 | All as per Item No 78.00 For Motor 10 HP Cap |
| 82 | All as per item No 78.00 for Motor 7.5/5 HP capNOTE: Quoted rates shall be deemed to include one year warranty formotors after rewinding and commissioning. |
| 83 | S&F in repairs the following component in existing LT Kiosks (Idoor/Outdoor) including disconnecting and taking down at different locations all as directed :-Voltmeter Digital type ,0-500 Volts of size 96x96mm. |
| 84 | All as per item No 83 but Ammeter Digital type of upto 400 amps capacity of size96X96mm. |
| 85 | M&L in repairs selector switch for voltmeter / Ammeter complete. |
| 86 | M&L in repairs Phase indicating lamp neon type complete with holder assy RYB phase complete. |
| 87 | M&L in repairs CT coils any capacity suitable for 1100volts, 50Hz, AC, supply complete. |
| 88 | Supply and adding Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containerscomplete all as specified and as directed.Brands having pan india availability, acceptability& being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. Note-: The chemical shall be brought in three lot and period to be procured only before previous batch completed. |
| 89 | Drilling and taping cast iron water mains (in position) for branch connections 15 mm bore of the internal dia. |
| 90 | -Ditto- all as per item No 89.0 above but 20mm bore |
| 91 | Taking up or down steel water tubing 15 mm bore and connections includingcleaning for re-fixing or removal. |
| 92 | -Ditto- all as per item No 91.00 above but 20mm bore |
| 93 | -Ditto- all as per item No 91.00 above but 25mm bore |
| 94 | -Ditto- all as per item No 91.00 above but 40mm bore |
| 95 | -Ditto- all as per item No 91.00 above but 50mm bore |
| 96 | M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting (if required) from any position / location as listed hereinunder and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete al as specified and as directed by the Engineer-In-Charge. Make:- ASIAN/BERGER/APCOLITE(a) Induction motors 25 HP/20 HP - 06 Nos.(b) Electric motors 10/7.5 HP - 03 No.(c) Sluice valve 100 mm dia. - 06 Nos.(d) Sluice valve 80 mm dia. - 06 Nos.(e) Electric Panel Board - 04 Nos |
| 97 | S & F in repairs foot valve of 150 mm bore, in cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge. |
| 98 | All as per item No 97.00 above but 80mm bore complete. |
| 99 | M&L for dismantling existing unserviceable sluice valve and supply and fix new sluice valve ISI marked IS-14846 PN 1.6 with iron operating wheel, flanged type rubber gasket, nut, bolts, washers, including any addition alteration. Fixing of new sluice valve of size 100 mm bore complete. |
| 100 | All as per item No 99.00 above but of 80 mm bore complete. |
| 101 | M & L for valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including dosmantling the existing valve chambercomplete all as specified and directed by EIC. |
| 102 | Supply, lay/fix, connect and testing steel water tubing, 25 MM medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to wall/ceiling or laid in trenches/floors including taking up/down existy tubinging and connections complete all as specified and directed by the Engineer-in-Charge. |
| 103 | All as per item No 102.00 above but of 40 mm bore. |
| 104 | All as per item No 102.00 above but of 50 mm bore. |
| 105 | All as per item No 102.00 above but of 80mm bore. |
| 106 | All as per item No 102.00 above but of 100mm bore. |
| 107 | S&F in repairs electronic timers for star-delta starter three phase 415 volts including taking down old unserviceable starters complete. |
| 108 | S&F in repairs pressure gauge 4\" dial 0-14 kgcm2. Make: Warrie / H-Guru / FIBIG |
| 109 | M & L in repairs forpoint wiring with PVCinsulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, including Modular cover plate of suitable size etc with necessary fixing accessories andearth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screws including taking down of old us fittings & wiring complete etc all as specified for one light / fan / bellpoint controlled by one switch. Note : 1.Two runs ofcable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.Make of conduit :- Sudhakar/ Precision/ Diamond,Make of wire :- Finolex/ Havells/ Polycab/ KEI |
| 110 | -Ditto- all as per item No 109 here-in-before but for one 6A 2pin/3pin switch socket out let multipurpose on independent Board. |
| 111 | All as per item No. 109 above but wiring complete with 2.5Sqmm for 3 pin 16A socket multipurpose on independent board |
| 112 | S&F modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 113 | S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 114 | S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed. |
| 115 | S&F modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. |
| 116 | S&Fmodular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed. |
| 117 | Supply & Fix Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed. |
| 118 | S & F Modularcover plate 8 modules complete. |
| 119 | S & F Modularcover plate 3 modules complete. |
| 120 | S & F Modularcover plate 1 modules complete. |
| 121 | S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed. |
| 122 | Supply & Fixing in replace Retrofit LED lamp 7 Watts complete all as specified and directed.Make : C&S/Bajaj/Havells/ Philips. |
| 123 | Supply & Fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. Make : Anchor/Kay Kay/Leader |
| 124 | Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. Make of Light Fitting :Shakti/Bajaj/Philips/Wipro |
| 125 | Taking down unserviceable FTL/batten fittings with supply and fix LED integrated batten of 10 Watt 2ft LED give minimum output lumen 1150 lm, efficiency >110, CCT 4000/6500K, CRI >80, power factor >0.9, operating temperature 45 degree celcious, THD <20% of housing aluminium extrusion with LED dimension 603mmx22mmx36mm upto 50% energy saving.Make of Light Fitting :Shakti/Bajaj/Philips/Wipro |
| 126 | S&F in repairs MCB DB SPN conforming to IP 43 - IK 09 with acrylic door,8 waycomplete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls. |
| 127 | Taking out Old U/S and S&F in repairs MCB SPN, 32 Amp, 10 KA, 230 Volt. |
| 128 | Taking out Old U/S and S&F in repairs MCB, single pole, upto 20 Amp, 10 KA, 230 Volt. |
| 129 | Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified. Model : Orient/Usha/Crompton/Havells/Bajaj/Polycab |
| 130 | Taking out unserviceable exhaust Fan and deposit to MES Store, supply and replacement with exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connecting with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified and directed. Make :- Havells/Crompton/Bajaj/Polycab/Usha. |
| 131 | Taking down deteriorted louvers and supplying and fix new louvers fixed type made out of 1.6mm GI sheet with horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x3mm flat iron base of size 45cmx45cm complete by providing of fixing arrangement for louvers upto 5th floor of including rate all as specified and directed by Engr-in-Charge |
| 132 | S&F in repair flame proof WP rotoy switch/Isolator 230 volt 10 A double pole ON / OFF with cable termination box in LM6, including anchor fasteners complete for allas directed |
| 133 | Supply and fix in repairs flame proof LED Light fittings CIMFR certified LED flameproof wellness in die cast AI housing with heat resistance toughened glass GLAZE PROLED Lights fittings 60 W . Recommendation for gas/Vapour group of IIA and IIB and Zone 1 & 2 IP65 pretected confirm to CAT No FWL1315-30-CDL of crompton or equivalent from Philips/Bajaj as approved by the GE. |
| 134 | S&F in replace of capacitor up to 2.5 mfd. Make:- Keltron/Epcos |
| 135 | S&F in Repairs/Replacement Ultra brightglass LED tube rod 20 Watts(Single/Double side connection), 230 volts with very high efficacy with G13 lamp holder including fixing arrangements and taking down old unserviceable tube rod complete. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO |
| 136 | S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitablefor LED tube 20/22 watts, 230 volts alongwith tube rod 22 watt (double side connection),including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO |
| 137 | Supply and fix in repairs SUPRA NEO-ILED Lights fittings 35 W wellglass in PDC Aluminium housing with finless design and exellent thermal management offering high durability and superior performance with energy saving and having efficacy of 110 Lm/W with provision of suitable fixing arrangement such as MS clamps,nut,bolts etc. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO |
| 138 | M&L for cutting existing road/hard standing not exceed 45x60 cm in wide and depth getting out excavated material for laying of cable returning filling & well ramming watering finish surface 10 cm from top including provision of PCC 1:2:4 for repairing, including removal of surplase soil all as directed. |
| 139 | Materials and Labour (M&L) for Reinforced Cement Concrete (RCC), Nominal Mix M-20 (using 20 mm graded stone aggregate), for foundations including rafts, footings, foundation beams, plinth beams, column bases, equipment foundations such as for electrical panels, DG sets, pumps, and other mass concrete works, complete all as specified and directed. |
| 140 | M&L in repair for point wiring for modular type fittings complete using proper colour coding, 1100Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed multi stranded copper conductor cable confirming to IS-694, Part II, ISI marked in and including PVC conduit medium grade not less then 25 mm dia, ISI marked with all accessories concealed in wall/ceiling etc, sunk pressed steel not less than 1.6 mm thick of suitable module, 50 mm deep terminal boxes with 3 mm thick ISI marked plastic laminated sheet top cover fixed with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi stranded copper conductor cable green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following:-Make of wire: KEI/ Polycab/ BENLO/ Anchor(Panasonic) Make of PVC Conduit pipe : Sudhir / Pressfit / Precision / Sudhakar / Kalinga / PlazaLocation: TS Mahul One light point controlled by one switch |
| 141 | One ceiling fan / exhaust fan point controlled by one switch |
| 142 | One three pin switch socket 6 Amps out let on independent board |
| 143 | One three pin switch socket 6 Amps out let on Same board |
| 144 | One Bell point controlled by one push flush type switch |
| 145 | All as per item No. 140.0here in before but with 2.5 Sqmm copper conductor with 2.5 Sqmm cable for earth conductor for one 3 pin 16 Amps socket outlet controlled by one switch. |
| 146 | S&F in repair/replacement of modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 147 | S&F in repair/replacement of modular type6A Two way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 148 | S&F in repair/replacement of modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 149 | S&Fin repair/replacement of modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 150 | S&F in repair/replacement of modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed. Location : TS Mahul, Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 151 | S & F in repair/replacement ofmodular type 120W step fan regulator, 2 module, single pole one way. 230 volts ISI marked and connecting up complete. Location : TS Mahul Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 152 | S & F in repair/replacement of ceiling rose surface bakelite 65x50 mm with 3 terminals complete all as specified and directed. Make : Anchor / Vinay / Legrand / Maru |
| 153 | Supply & Fix in repair/replacement Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed. Location : TS Mahul |
| 154 | Supply and fix bell ding dong AC 230 V single pole.complete all as specified and directed. |
| 155 | S & F in repair/replacement of Modularcover plate 12 modules confirming to IS : 14772: 2000 all as specified and as directed.Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) Location : TS Mahul |
| 156 | S & F in repair/replacement of Modularcover plate 8 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 157 | S & F in repair/replacement of in repair/replacement of Modularcover plate 6 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 158 | S & F in repair/replacement of Modularcover plate 4 modules confirming to IS : 14772: 2000 all as specified and as directed.Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 159 | S & F in repair/replacement of Modularcover plate 3 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 160 | S & F in repair/replacement of Modularcover plate 2 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 161 | S & F in repair/replacement of Modularcover plate 1 modules confirming to IS : 14772: 2000 all as specified and as directed.Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) Location : TS Mahul |
| 162 | S&F in repair/replacementsingle pole and neutral enclosure with a two pin and earthand metal cladplug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified including concealing in wall and directed. Location : TS Mahul Make :- LEGRAND/ SCHEINDER/ L&T |
| 163 | Supply and fixing in repair/replacement16 Ampere, 3-pin plug top, heavy-duty, ISI-marked, moulded type, suitable for operation on 240V single-phase AC supply. The plug top shall be made of high-grade, fire-retardant, impact-resistant polycarbonate/ABS body with brass pins and terminals for superior conductivity. The design shall include a robust gripping arrangement, strain-relief for cable entry, and ensure firm contact engagement with matching sockets. Location : TS Mahul Make: Anchor / Havells / Legrand / Schneider or equivalent. |
| 164 | Supply and fixing in repair/replacement of Universal (UNI) switch socket combined unit, factory-assembled, modular type, suitable for operation on 240V, 50Hz, single-phase AC supply. The unit shall consist of one universal 6A/16A 3-pin socket and a modular switch (6/16A) housed in a suitable front plate with flush mounting box, made of high-strength, fire-retardant, UV-stabilized polycarbonate/ABS material. The unit shall be ISI-marked, conforming to IS:1293/IS:3854, with brass terminals and silver-plated contacts for reliable conductivity. Complete installation including interconnections, earthing, and fixing accessories. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 165 | Supply and fixing in repair/replacement of 6 Ampere, one-way, non-modular switch, piano-type, ISI-marked, suitable for 240V, 50Hz single-phase AC supply. The switch shall be made of high-quality, fire-retardant, shockproof thermosetting material with brass terminals and silver-plated contacts for smooth operation and long service life. Complete with necessary accessories for surface or flush mounting. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 166 | Supply and fixing in repair/replacementof 16 Ampere, combined switch and 3-pin socket unit, non-modular type, ISI-marked, suitable for 240V, 50Hz single-phase AC supply. The unit shall be made of heavy-duty, fire-retardant, shockproof thermosetting material with brass terminals and silver-plated contacts, complete with necessary mounting box, front plate, and fixing accessories. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 167 | Supply and fixing in repair/replacementof surface mounting box suitable for accommodating 6-module (6M) modular switches, sockets, and accessories, made of high-quality, fire-retardant, shockproof, UV-stabilized polycarbonate/ABS material. The box shall have adequate space for wiring, pre-punched knockouts for conduit entry, and provision for secure mounting on wall surfaces. It shall be complete with all fixing accessories and conform to relevant IS standards. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 168 | Supply and fixing in repair/replacementof Hylam (Bakelite) sheet back panel, size 14\" x 6\", suitable for electrical switchboard mounting. The sheet shall be made of high-grade, industrial-quality phenolic laminated material, white, heat-resistant, shockproof, moisture-resistant, and durable, providing a strong insulating base for switchgear and fittings. Sheet shall be unpolished/unfinished and supplied complete with drilling and cutting as required for installation. Location : TS MahulMake: Hylam / Formica / Equivalent ISI-marked brand. |
| 169 | Supply and delivery in repair/replacement of hydraulic crimping tool suitable for crimping insulated and non-insulated copper/aluminium cable lugs and connectors. The tool shall have a crimping capacity up to 400 sq.mm (or as specified), equipped with interchangeable, precision-machined crimping dies, a two-stage hydraulic system for smooth operation, and an ergonomic handle with anti-slip grip. The tool shall be portable, heavy-duty, and designed for field and workshop use, conforming to relevant IS/IEC standards. Location : TS MahulMake: Jainson / Dowells / Stanley / Klauke / Solwet or Equivalent. |
| 170 | M&L for Load balancing of LT Panels and Distribution Boards, including detailed load survey using clamp meters/analyzers, preparation of redistribution plan, safe isolation and lockout/tagout procedures, rearrangement and re-termination of outgoing feeders (single/three-phase) with proper torqueing, replacement of defective lugs/ferrules, insulation resistance and continuity testing, use of approved consumables (cable ties, sleeves, insulation tapes), post-balancing load verification, and submission of calibrated test reports, complete all as specified and directed and in accordance with IE Rules, IS Standards, and site safety norms complete all as specified and directed by Engr-in-Charge. Location : TS Mahul |
| 171 | S & F in repair/replacement of 35/36W recessed type 2*2 LED based having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95,LED lamp suitable for roof ceiling including fixing mounting blocks 2 Nos, 15 mm MS conduit,electrical connection with 3 core flexible Copper conductor cable of 1.5sqmm size from ceiling rose to the fixture complete all as specified and directed. Location : TS Mahul Make : Bajaj / Wipro / Jaquar |
| 172 | S & F in repair/replacement of 36 W ceiling surface light of size (2x2ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, Including electrical connection with 3 core flexible copper conductor cable of 1.5 sqmm appropriate size from ceiling rose to the fixture complete all as specified and directed.cat / model No BCTBLS 43 ZT WH of bajaj or equivalent inwipro / Jaquar/ Bajaj Location : TS Mahul |
| 173 | S & F in repair/replacementof security light fitting/Building security lightLED type 120 watts, THD<10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc including taking out old u/s security lights all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS. Location : TS Mahul |
| 174 | S & F in repair/replacementof security light fitting/Building security lightLED type 60 watts, THD<10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc including taking out old u/s security lights all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS. Location : TS Mahul |
| 175 | Supply and fixing in repair/replacementof LED securitylight fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection 4 kv surge in built protection completeall as per directed by Engr- in – charge. NOTE-: The Contractor shall furnished 3 year minimum written warranty Clause on LED luminaries from OEM. Location : TS Mahul Make : Bajaj/Crompton/wipro/Jaquar |
| 176 | S & Fin repair/replacementof decorative 15 Watts LED (Ruby clear type, IP-65) New generation, post Top energy saving, environmental friendly, long life aesthetically disigned with symmetical light distribution, spun aluminium landscape luminaire with high power LED\"s as light source including mounting arrangementupto 2.00 mtr height with medium grade GI tubing of suitable dia alongwith MS angle bracket/framed covers including clamps, bolts nuts, painting by aluminium paint complete all as specified and dierected by Engr-in-Charge. Location : TS Mahul The fitting shalll conform to cat No - RUBYMINIPT15WLED757PSYMTOPC of Havells or Equivalent from Crompton/Bajaj. |
| 177 | Supply & Fix in repair/replacement of 8 watts LED(CONE-IP 65) Bollard Garden light fittings Cone series acts as an imposing street furniture.The elegant yet minimalistic design acts a silent observer and giving light, diffuser at the upper portion adds functional value into landscape environment.including driver, nuts, bolt, washers, base plate , Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation0.3 Meter x 0.3 Meter x 0.3Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, including mounting arrangementupto 2.00 mtr height with medium grade GI tubing of suitable dia 50mm alongwith MS angle bracket/framed covers, clamps complete , the Fitting Shall Conform to Cat No - CONEBLSWLED857PSYMTOPCM of Havells or Equivalent from Bajaj/Crompton Location : TS Mahul |
| 178 | S & F in repair/replacement of 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including fixing mounting blocks 2 Nos, 15 mm MS conduit,electrical connection with 3 core flexible Copper conductor cable of 1.5sqmm size from ceiling rose to the fixture complete all as specified and directed. Location : TS Mahul Make : Bajaj / Wipro / Jaquar |
| 179 | Supply and fixing in repair/replacement of of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including fixing mounting blocks 2 Nos, 15 mm MS conduit,including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed Location : TS Mahul, Make : Bajaj / Wipro / Jaquar |
| 180 | Supply and replace in repairs aviation light LED based operations on 230V, 50 Hz AC supply comprising 302 No x 5mm supper flux LEDsmade out of direct aluminum housing with Red polycarbonate dome for illumination, having integral driver, with IP65 protection, and 50,000hrs bearing cappacity minimum, system wattage ≥ 10(w), Contractor shall provide all necessary components including rods for mounting, brackets, cabling, and protective devices, establishing electrical connections, and configuring automatic dusk-to-dawn operation viatimers complete all as specified and directed.Location : TS MahulMake : Bajaj Model No. Cat No. BGAV302 LED or equivalent model from make Halonix/Shakti |
| 181 | M&L in repair/replacement for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/ PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints.Location : TS Mahul, Make: Raychems / Densons / M Seal / Birla 3M / Yamuna Gases & Chemicals |
| 182 | -Ditto- all as per item No 181 here-in-before but 3.5/4 core 50 Sqmm to 95 Sqmm size -do- |
| 183 | -Ditto- all as per item No 181 here-in-before but 3.5/4 core 120 Sqmm to 185 Sqmm size -do- |
| 184 | -Ditto- all as per item No 181 here-in-before but 3.5/4 core 240 Sqmm to 400Sqmm size -do- |
| 185 | S&F in repair/replacementfor Multistandarded Copper Conductor PVC insulated, 1100 volts grade cable of 3 Core 1.5 Sqmm size for interconnection of cable looping box to street Light Fitting fixed on the pole including taking down old unsv cable, complete all as specified and directed. Location : TS Mahul, Make: Polycab / KEI / Anchor (Panasonic) / Gloster / Havells |
| 186 | Supply and Laying in repair/replacementor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core in trenches,along the wallincluding necessary connection and providing cable lugs as required includingdisconnection/taking down of existing unsvcable all as specified. Location : TS Mahul, Make: Polycab / KEI / Anchor (Panasonic) / Gloster |
| 187 | -Ditto- all as per item No 186 above here-in-before but 70 Sqmm 3.5 Core -do- |
| 188 | -Ditto- all as per item No 186 above here-in-before but 50 Sqmm 3.5 Core -do- |
| 189 | -Ditto- all as per item No 186 above here-in-before but 35 Sqmm 3.5 Core -do- |
| 190 | -Ditto- all as per item No 186 above here-in-before but 25 Sqmm 3.5 Core -do- |
| 191 | -Ditto- all as per item No 186 above here-in-before but 16 Sqmm 4 Core -do- |
| 192 | -Ditto- all as per item No 186 above here-in-before but 10 Sqmm 4 Core -do- |
| 193 | M & L in repair/replacement for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85* C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm NB UPVC medium grade surface/recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS:732- 1989, including making good of disturbed surfaces of wall/celling/floor, all complete as specified and directed. Location : TS MahulNOTE: One run of phase conductor, One run of neutral conductor, One run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length(a) 2 X 1.5 mm2 + 1 X 1.5 mm2 earth wire |
| 194 | (b) 2 X 2.5 mm2 + 1 X 2.5 mm2 earth wire |
| 195 | (c) 2 X 4.0 mm2 + 1 X 4.0 mm2 earth wire |
| 196 | (d) 2 X 6.0 mm2 + 1 X 4.0 mm2 earth wire |
| 197 | S&F of HDPE pipe 50 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etc complete all as specified and directed. Location : TS MahulMake: PLASTO / PRECISION / SUPREME / SUDHAKAR / DUPLON / TIRUPATI / FINOLEX |
| 198 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Location : TS Mahul Make - Hensel cat part No KF1616B /National/Sintax |
| 199 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 130 x 180 x 77mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Location : TS Mahul Make - Hensel cat part No KF1010B /National/Sintax |
| 200 | Supply and Fix, in repair, MCCB 400 Amps, 36 kA, 4-Pole, 415 Volts, including disconnection of unserviceable MCCB, installation, and connection in the existing panel using suitable cable lugs, glands, and accessories, complete all as specified and directed. Location : TS Mahul Make: L&T / C&S / Havells / Legrand / Schneider / ABB / Siemens. |
| 201 | All as per item No 200 above but MCCB 250 Amps, 25 kA Triple Pole 415 Volts |
| 202 | All as per item No 200 above but MCCB 200 Amps, 25 kA Triple Pole 415 Volts |
| 203 | All as per item No 200 above but MCCB 125 Amps, 16 kA Triple Pole 415 Volts |
| 204 | All as per item No 200 above but MCCB 100 Amps, 16 kA Triple Pole 415 Volts |
| 205 | All as per item No 200 above but MCCB 63 Amps, 16 kA Four Pole 415 Volts |
| 206 | All as per item No 200 above but MCCB 40 Amps, 16 kA Four Pole 415 Volts |
| 207 | S & Fin repair/replacement of MCB DB, 12 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall,making good the disturbad surfaces and making all connections,complete all as specified and directed. Note: Quoted rate shall also be deemed to include for provision of copper bus bar of 200 Amps rating. Location : TS Mahul Make :- LEGRAND/ SCHEINDER/ L&T/ ANCHOR (PANASONIC)/ SCHNEIDER/ INDO ASIAN |
| 208 | S & F in repair/replacement of MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall,making good the disturbad surfaces and making all connections,complete all as specified and directed. Note: Quoted rate shall also be deemed to include for provision of copper bus bar of 200 Amps rating. Location : TS Mahul Make :- LEGRAND/ SCHEINDER/ L&T/ ANCHOR (PANASONIC)/ SCHNEIDER/ INDO ASIAN |
| 209 | Supply, installation, testing and commissioning in replacement of of 4 Way Vertical TPN (VTPN) Double Door Distribution Board, sheet steel enclosure, dust and vermin proof, IP-43 protection, with copper bus bars rated 200A, neutral link, earth bar and provision for incomer MCCB/Isolator and outgoing MCBs/ MCCBs as required, suitable for 415V, 3 phase, 4 wire, 50Hz AC supply, including necessary accessories, earthing connections, painting, interconnections, and making good the disturbed surface complete as per specification and as directed by Engineer-in-Charge. Location : TS MahulMake: L&T / Schneider / Siemens / ABB / Legrand / Havells. |
| 210 | S & F in repair/replacement of MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity\"C\" series complete. Location : TS MahulMake :- LEGRAND/ SCHEINDER/ L&T |
| 211 | S & Fin repair/replacement of MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity\"C\" series complete. Location : TS MahulMake :- LEGRAND/ SCHEINDER/ L&T |
| 212 | Supply & Fixing Jumbo Lamp Holder Batten Type, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. Location : TS MahulMake : Bajaj / Wipro / Jaquar |
| 213 | Supply and fixing in replacement of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, High Speed with service value 6.00 minimum BEE 5 star rated with brushless direct current motor (BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge.Make : Bajaj (Energos 28) / Orient (Falcon 400) / Havell’s (Efficiencia Neo BLDC 26W) Note Location : TS Mahul : Unserviceable ceiling fans shall be deposit to MES store. |
| 214 | Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out capacitor 2.5 mfd - 01 No., PVC canopy - 02 No\"s and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site complete all as directed. Location : TS Mahul Location |
| 215 | Supply & fix in repair/replacement of Heavy Duty metallic Exhaust fan of sweep 300 mm sweep with frames, blades, mounting anchor fasteners, aluminium louvers made of aluminium sheet of 0.5 mm thickness, rovision of three core 1.5 Sqmm copper cable from celling rose to fan, making opening of required in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4, Including scafolding if any required to cary out the work in building of height up to 20 Meters complete in all respects the Exhaust Fan Shall Conform to Cat no EXHD380-4-1 of Crompton or Equivalent from Bajaj/GE. Make :- ALMONARD / ORIENT / USHA / BAJAJ / CROMPTON / HAVELLS Note : Unserviceable ceiling fans shall be deposit to MES store. Location : TS Mahul |
| 216 | Taking down old unserviceable Exhaust fan 300 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site complete all as directed. Location : TS Mahul |
| 217 | Supply and fix in repair/replacement of exhaust fan made of sturdy Engineering rust proof ABS Plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed. Make :- ALMONARD / ORIENT / Bajaj / Havells Location : TS Mahul |
| 218 | Supply and delivery in repair/replacement of 2.5 MFD capacitor, suitable for single-phase AC applications, rated for 440V AC, 50Hz. The capacitor shall be metallized polypropylene (MPP) type, self-healing, oil-free, hermetically sealed in a cylindrical aluminium or plastic canister, and equipped with PVC-insulated flexible lead wires for easy connection. It shall be designed for continuous duty in fans, pumps, and motor-start/run applications, conforming to IS 2993/IEC standards. Location : TS MahulMake: L&T / Havells / EPCOS / Crompton / Equivalent. |
| 219 | Supply and fix, in repair, factory-fabricated louvers/shutters suitable for exhaust fans of sweep size up to 300 mm, made of high-strength, powder-coated aluminium, rust-proof and weather-resistant, complete with gravity-operated or spring-loaded self-closing blades designed to prevent backdraft of air, dust, insects, and rainwater ingress. Louvers shall be aerodynamically profiled for smooth airflow and low-noise operation. The assembly shall include a robust frame, all necessary mounting hardware, fasteners, and accessories, and shall be installed in position, all as specified and directed. Location : TS MahulNote:(i) The arrangement of necessary equipment, such as ladders, scaffolding, or cranes, for accessing and working on exhaust fan openings/locations shall be arranged and provided by the contractor, and the cost of such arrangements shall be deemed to be included in the quoted rate. |
| 220 | Supply and erect in repairto truly vertical position 9m long steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP- 31, conforming to IS: 2713 (Part-I, III)-1980, including painting with two coats of aluminium paint over a coat of zinc chrome primer to exposed surfaces and two coats of black bituminous paint to embedded surfaces, excavation earthwork in any type of soil complete all as specified and as directed Location : TS Mahul |
| 221 | Supply and erecting in repairof hot dip Galvanised Octagonal poles of height 6 mtr with 130mm bottom dia and 70mm dia top made up of 3mm thick high tensile sheet along with base plate of size 225x225x12mm thick including 4 nos of M24x750mm long J type foundation bolts and 1mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Location : TS MahulMake Jindal/Bajaj/Crompton Greaves |
| 222 | S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge |
| 223 | M&L for fabricating and fixing MS angle iron in replacement of size 25x25x5MM,flat iron and brackets etc for fabrications for fixing flood light in wall ,poleincluding nuts,bolts,washers,welding to shapes for fabrication of structure to fix flood light including necessary cutting/jointing/welding with one coat of red oxide and two coats of synthetic enamel paints complete all as specified and directed. |
| 224 | Supply and fixin repair Power Capacitors of Rating 20 KVAR 415 Voltin repairs Naturally air cooled Double dielectric heavy duty, MPP type440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified. Location : TS Mahul |
| 225 | All as per item No 224 above but Power Capacitors of Rating 15 KVAR 415 Volt |
| 226 | All as per item No 224 above but Power Capacitors of Rating 10 KVAR 415 Volt |
| 227 | All as per item No 224 above but Power Capacitors of Rating 7.5 KVAR 415 Volt |
| 228 | All as per item No 224 above but Power Capacitors of Rating 5 KVAR 415 Volt |
| 229 | M & L spray painting inside, outside complete tothe LT panel boards outdoor type of size not exceeding 2.0 Mtrwidth 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. |
| 230 | Supply and fix in repairs stainless steel cable glands required for cable entry in Panel of size from 10 sqmm to 50 sqmm etc. complete all as specified and directed. Location : TS Mahul |
| 231 | -Ditto- all as per item No 230 above here-in-before but for 70 sqmm to 120 sqmm complete all as specified and directed. |
| 232 | -Ditto- all as per item No 230 above here-in-before but for 150 sqmm to 300 sqmm complete all as specified and directed. |
| 233 | Supply only CTC/ CRC solution spray to remove out the moisture and corrosion content from electrical equipement complete all as specified and directed. Location : TS Mahul |
| 234 | Supply only cotton waste industrial type for cleaning of electrical equipment , Panel board etc complete all as specified and directed. |
| 235 | M&Lin repairs for 24 Hrs240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE Location : TS Mahul |
| 236 | Comprehensive AMC of three phase 60 KVA UPS 3 phase,including servising/replacement of worn out parts like PCB,IGBT based, Diode, Capacitors,relay,cooling fan,indicators,connectors,lugs,wires,switches,fuses andto attending all brakdown calls and check all electronic component/cards,checking of rectifier/inverter logic boards,adjust battery charging current,cheking of auto transfer facility between inverter and bypass & bypass to UPS, verification/setting/rectification of LCD mimics alarms,indications, UPS &battery changover test. Location: RUKMANI Bldg Mahul |
| 237 | Comprehensive AMC of 30 KVA 3 phase,415 V Servo voltage stabilizer (6 Nos) including replacing of all components releted with AVR following:-(a) I.C. Electronic control card(b) Control Transformer(c)R.C. Network (d)Main big gear (e) Toggle switch(f) Indication Lamp (g) Voltmeter (h) A.C. synchronous Motor(i) Dimmer stopper all as specified and directed by Engineer –in –Charge.Note: (i) The rate quoted shall be inclusive transportation,material and labour,including all defective spare makeas per existing,complete. (ii) Attending of fault within 8 hours of intimation to avoid disruption of receive to user technical requirement.Delay of attending of fault by more than 01 day wound invite penalty charge of 1000/hr. Location : TS Mahul |
| 238 | Supply only PVC Electrical Insulation Tapeof superior quality, self-adhesive, fire-retardant PVC electrical insulation tape of size 1.7 cm (width) x 6 m (length) x 0.125 mm (thickness), providing excellent grip and durability supplied in pack of 30 rolls complete all as directed by Engineer-in-Charge. Make :Pidilite Steelgrip.Location : TS Mahul |
| 239 | Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron strip 32 X 6 mm dia by means of bolts, washers, watering pipe 20mm dia, medium gradeGI pipe, with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fittingas protection pipe for strip from earthing plate electrode to test point including concrete pit in PCC (1:3:6) type C-Iand pre-caste RCC 1:2:4 type B-1 cover with 8mm dia MS handle. Charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as show in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed. Location : TS Mahul |
| 240 | Note: (1) 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately(2) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate.(4) The Execavation shall be done manually by man power, the quoted rate is inclusive of digging out roots.(5) The qoted rate is deemed to be inclusive of removal of the excess material from the work site. |
| 241 | Supply & fixing for Aluminium strip 25 x 3.15mmon wall/ roof/ batten or recessed or buried in ground including all insulators, screw, nut bolts with saddles and fixing for roof conductor and down conductor complete all as directed by Engineer-in-Charge. Location : TS Mahul |
| 242 | Supply & fixing for Galvanised iron strip 32 x 6mmon wall/ roof/ batten or recessed or buried in ground including all insulators, screw, nut bolts with saddles and fixing for roof conductor and down conductor complete all as directed by Engineer-in-Charge. Location : TS Mahul |
| 243 | M&L in repair/replacementfor Test-Point Terminal Block — non-ferrous, made of gun metal or phosphor bronze, overall size not less than 75 × 75 × 25 mm; edges deburred, contact faces smooth and true; factory drilled and screwed; including 3 Nos. hex-head machine screws, 8 mm dia × 25 mm long, with matching nuts and plain/spring washers; complete with drilling, tapping, fixing to board/wall as directed and testing on completion. Location : TS Mahul |
| 244 | Supply and fixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including allfittings for fixing complete as required and directed by Engineer-in-Charge. Location : TS Mahul |
| 245 | Supply and Fix in repairs Push buttons complete of colour red/ green with NO/NC elements, operating on 230 V, 50Hz, AC supply complete all as specified and directed. Location : TS Mahul |
| 246 | Supply and Fix in repairs Selector Switch 3 Positionsuitable for LT panels, operating on 230 V, 50Hz, AC supply complete all as specified and directed. Location : TS Mahul |
| 247 | S & F in repairs LED based complete(R Y B ) for mounting on LT panel, operating on 230 V, 50Hz, AC supply complete all as specified and directed. Location : TS Mahul |
| 248 | M&L for draining out water, thoroughly cleaning and removing accumulated sludge, dirt, and scale from the bottom, walls, ceiling, and mouths of circulating pipes of service tanks/PVC tanks of capacity not exceeding 500 litres located on the rooftops of buildings. The work includes disinfection of tanks using bleaching powder to ensure they are bacteria-free, removal of all previously written dates from the tank surface, and depositing the removed waste in low-lying areas of defence land as directed. After cleaning, the date of cleaning shall be stenciled in white synthetic enamel paint on a black background, in 100 mm high letters, in the format: \"CLEANED ON (DATE) DUE ON (DATE)\", complete all as specified and as directed. Location : TS Mahul |
| 249 | Ditto all as per item No 247 above but capacity of tank exceeding 500 Ltrs andupto 1000 Ltrs |
| 250 | Ditto all as per item No 247 above but capacity of tankexceeding 1000 Ltrs and upto 2000 Ltrs |
| 251 | Ditto all as per item No 247 above but capacity of tankexceeding 2000 Ltrs and upto 3000 Ltrs |
| 252 | Ditto all as per item No 247 above but capacity of tank exceeding 3000 Ltrs and upto 5000 Ltrs |
| 253 | S&F in repairs gunmetal gate or globe valve for 50 mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete including taaking down old unserviceable valves all as specified and as directed. Location : TS MahulMake :- Leader / Zoloto / Shakti |
| 254 | Ditto all as per item No 252 above but 40 mm dia bore complete. Make :- Leader / Zoloto / Shakti |
| 255 | Ditto all as per item No 252 above but 25 mm dia bore complete.Make :- Leader / Zoloto / Shakti |
| 256 | Ditto all as per item No 252 above but 20 mm dia bore complete. Make :- Leader / Zoloto / Shakti |
| 257 | Supply of Calcium Hypochlorite Granules, white in appearance, in granular form, with a minimum available chlorine content of 65% to 70%, suitable for disinfection and water treatment applications. The material shall have controlled moisture content (4.00–10.00%), water insoluble matter (4.00–6.00%), and sodium chloride content not exceeding 15%. Granular size shall comply with ASTM standards, with a minimum of 96% retained on ASTM 14 sieve and a maximum of 4% passing through ASTM 100 sieve. The product must exhibit high stability with a maximum 10% loss and maintain a pH of 11–12 in 5% aqueous solution. Material shall be delivered in moisture-proof packaging suitable for storage and handling complete all as specified and as directed. Location : TS MahulMake:-1.Aqufit manufactured by Sree Rayalaseema Hi strength Hypo Ltd.2. Puri chlor manufactured by Sree Rayalaseema Hi strength Hypo Ltd. / M/s Ravi Enterprises / M/s Potter & Watts (Traditional products). Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. 3. Best available in the market |
| 258 | Supply and fix in repair PVC Ball valve 20 mm bore ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed including taking down old unserviceable ball valves complete. Make :- PRAYAG / SHAKTI / AGROTECH |
| 259 | Ditto all as per item No 257 above but25 mm bore complete. |
| 260 | Ditto all as per item No 257 above but40 mm bore complete. |
| 261 | M&L for electric water pump in repairs (self priming) of capacity 0.5 HP, 220V, 50 Hzhead range 06 to 24 m, insulation class B conforming to Crompton Mini force II commissioning and testing to make it operational / functionalcomplete all as specified and asdirected. Location : TS Mahul, Make: Kirloskar / Beacon / Crompton Greaves / KSB / Wilo Mather & Platt / Jyoti / V Guard |
| 262 | Taking out old/ unsv cast iron/ MS tank cover from RCC tank including dismatlling of RCC base support/ MS or cast iron frame and supplying & fixing cast iron tank cover in round shape of size 21 inches internal dia, with proper anchor in PCC with nut, bolts, anchor fastner etc with locking arrangement etc complete with two coats of black bituminous paint (drinking grade) for 1000 ltr/ 2000 ltr/ 3000 ltrall as specified and as directedLocation : TS MahulNote-: Plastering and PCC work shall measured and paid seperately |
| 263 | Dismantling of existing PVC water storage tank covers and Supplying and fixing PVC tank cover round shape of suitable size as per ground requirement with locking arrangement and fixed in position etc complete all as specified and as directedLocation : TS Mahul |
| 264 | Supply only Bleaching powder grade -I ISI marked having stable available chlorine % by mass minimum 35% as per IS 1065,1971 and packed in 25 Kg bag complete all as specified and directed. Location : TS Mahul Make : Vikram or equivalent as approved by GE. |
| 265 | Maint/Cleaning ofPump house stations/Substation/ E/M installationinside and out side area and removing of creepers and vegetation raised along with water supply installation including surface dressing around the E/M installation not less then 3 mtrfrom out side fencing and removing the all waste material from site and Chemical spray inside and out side area of Sub station. Location : TS MahulNote:- T & P will be arranged by contractor |
| 266 | M & L for preparation of existing painted steel pipes, including CI/DI line, and all exposed GI pipes, by removing the deteriorated paint layer through manual or mechanical scraping using wire brushes, scrapers, or sandpaper. The surface shall be thoroughly cleaned to remove dust, grease, rust, or any contaminants, ensuring an even, bare metal or sound substrate ready for painting and apply one coat of synthetic enamel paint, ensuring uniformity in thickness and adherence as per manufacturer specifications shall comply with IS standards, apply a compatible metal primer on bare metal sections before enamel application to enhance corrosion resistance and paint adhesion complete as per specifications and as directed by the engineer-in-charge. Location : TS Mahul. Make :- Asian, Berger, Apex, or Nerolac |
| 267 | Material and labour for preparingold painted steel pipe surface such as Rising pipe (Red), Delivery pipe (Blue), Overflow pipe washout pipe (Yellow) etc and applying one coat of synthetic enamel paint include the removal of existing deteriorated paint layers using suitable mechanical or manual methods such as scrapers, wire brushes, or sandpaper, ensuring a clean and smooth substrate complete all as specified and as directed.Location : TS MahulNote:- (i)The arrangement of necessary equipment, such as ladders, scaffolding, or cranes, for accessing and working on pipes, shall be managed and provided by the contractor, and the cost of such arrangements is included in the quoted rate. |
| 268 | Supply and fixing in replacement First aid box PVC body with complete kit/accessories wall mounting type all as specified and directed. Location : TS Mahul |
| 269 | S&F in repairs chlorine testing KIT with colored sample complete with all testing fitment and OT solution in rexine finish box. Location : TS MahulMake :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 270 | S&F in repairs chloroscope (Chlorine & PH test kit) for estimation of residual chlorine in water comprises of Plastic box,two tube, Droper and colour filter for colour estimation. Location : TS MahulMake :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 271 | S&F in repairs Water Quality TDS tester with ATC, Digital and Pocket type,Range : TDS 0-999 PPM(Mg/L) Model No :- ATDS0016. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 272 | Supply & Fix in repair fully automatic star delta starter suitable for upto 25 HP, 440 volt, 3 Ph Elect Motor with Single Phase Protection feature conforming to IS -13947 after taking down old unserviceable one anf fixed to the same location by making electrical connection properly complete all as specified and as directed. Cat No: SS91855 of Make-L&T or equivalent to C & S / Schneider / CROMPTON Location : TS Mahul |
| 273 | S&F in repairs Direct on line (DOL) starter in sheet steel enclosure AC 3 phase 415 volt 50 Hz suitable for 5/7.5HPcomplete. Location : TS Mahul |
| 274 | M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using computerised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Location : TS MahulNote: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately.(ii) Cable joint will be measured and paid seperetely.(iii) Additional lenth of cable required at site for jointing will be measured and paid seperately. |
| 275 | Supply and Fix in repair replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating,Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system Location : TS Mahul |
| 276 | All as per item No 274 above but Contactor Three Pole 415 volts40Amps AC 3 RatingConforming to Type- MNX - 40 & Cat no - CS94190of L & T or equivalent from Schnider Electric/ABB/ C&S |
| 277 | All as per item No 274 above but Contactor Three Pole 415 volts50 Amps AC 3 Rating Conforming to Type-MNX - 50 & Cat noCS-97075of L & T or equivalent from Schnider Electric/ABB/ C&S |
| 278 | All as per item No 274 above but Contactor Three Pole 415 volts70 Amps AC 3 Rating Conforming to Type- MNX - 70 & Cat no - CS-97076of L & T or equivalent from Schnider Electric/ABB/ C&S |
| 279 | Supply & Layingfixing, connecting and testing in repair/replacement of steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc including taking down old u/s pipes complete all as specified and as directed for the 20 mm bore, ISI marked. Location : TS Mahul,Make-: Tata/ Jindal/ BST/ Oswal |
| 280 | Ditto all as per item No 278 above but 25 mm dia bore complete |
| 281 | Ditto all as per item No 278 above but 40 mm dia bore complete |
| 282 | Ditto all as per item No 278 above but 50 mm dia bore complete |
| 283 | Ditto all as per item No 278 above but 80 mm dia bore complete |
| 284 | Ditto all as per item No 278 above but 100 mm dia bore complete |
| 285 | Supply and replace in repairs of New water meters confirming to ISO 4064:2005,including MS flange,nut bolts,rubber packing and flange thickness conforming to IS:7322-1985 and flange dimension conforming IS: 1538-1993 of size 100 mm dia suitable for installation on MS/DI/CI pipe line, including taking out old u/s water meter complete all as directed by Engineer in Charge. Location : TS MahulMake: Chambal/Kranti/Capston/Dashmesh/Accuflow or equivalent. Note: (a) Cleaning and grinding by 3 core welding of the pipe outside welding of the joint including cost of gas oxygen acetylene,welding machines, skilled and semi skilled workers internal lighting arrangements and all other incidental and operational charges etc.(b) The scope of work is inclusive of following and rate quoted is deemed to be inclusive in the amount quoted |
| 286 | M&L for complete rewinding and overhauling of 10 HP, 3-phase, 50 Hz, 415V electric motor, including disconnecting and dismantling existing burnt winding, rewinding with super-enameled copper wire of appropriate gauge using standard insulation materials (PVC sheets, cotton tape, sleeves, varnish, etc.), transportation of motor to and from workshop including loading/unloading, replacement of 2 Nos. ball bearings (make: SKF/NBC/TATA), renewal of terminal plate with brass studs, nuts, bolts, and washers, reinstallation at site with proper alignment, connection, and load testing, along with dismantling, cleaning, and overhauling of the coupled centrifugal/monoblock pump including replacement of defective components such as impellers, bushes, thrust bearings, clutch system, bowl assembly, pump shaft, and other unserviceable parts as required, followed by reassembly, alignment, commissioning, and on-load testing to ensure full operational efficiency, complete all as specified and directed. Location : TS Mahul |
| 287 | All as per item No 285 for Motor 7.5/5 HP capNOTE: Quoted rates shall be deemed to include one year warranty formotors after rewinding and commissioning. |
| 288 | Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismentaling of blades canopy down rod etc & remove to store for repair. & Refix the same including provision of 3 core 0.5 sq mm copper flexiable cable from ceiling rose to connector.Note(i) The representative of the contrcator shall report to Engineer-in-charge/JE on daily basis to carry out repairs to fan and the defects should be rectified on the same day |
| 289 | M&L for Opening of cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge. Note - Spares such as Bearing, Capacitor, Capacitor Clamp, Rubber insulator will be measured seperately under respective item of this schedule (a) Ceiling fan 1200 / 1400 mm Sweep. |
| 290 | (b) Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep. |
| 291 | (c) Exhaust Fan, Pedastal fan,wall fan,450/600 mm Sweep. |
| 292 | (d) Painting onlyof ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, sscraping out of old paint filling of cavities with filler preparationof body and cleaning of dust etc Painting by Spray with first Quality Paint including over quot ofzinc primer writing ofMes number complete for allas directed :- |
| 293 | (e) Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing Note : Spares shall be measured & paid resperative item of this sch. |
| 294 | Supply only spare parts to be incorporated for repairing fans in respective item of this schedule(a) Capacitor up to 2.5 Mfd MAKE KELTRON,EPCOS |
| 295 | (b) Capacitor 3.15/ 4 MFDMAKE KELTRON,EPCOS |
| 296 | (c) Capacitor Clamp with Connector As Par Sample |
| 297 | (d) Rubber Insulator sutiablefor any type ofCeiling Fan. |
| 298 | (e) Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample |
| 299 | (f) Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample |
| 300 | (g) Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc mplete 300 mm sweepas par sample |
| 301 | (h) Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete380/ 450 mm sweepas par sample |
| 302 | (j) Ball bearing sutiable for any type of fans Make : SKF,TATA,NBC |
| 303 | (k) Mild steel shaft as per sample for any fan |
| 304 | (l) Ceiling Fan Blade suitable for 1200/1400 mm sweep as per sample. |
| 305 | (m) Exhaust Fan Blade suitable for 300 mm sweep as per sample. |
| 306 | (n) Exhaust Fan Blade suitable for 450 mm sweep as per sample. |
| 307 | (o) Pedestal/WallFan Blade suitable for 450 mm sweep as per sample. |
| 308 | (p) Pedestal / Wall Fan Blade suitable for 600 mm sweep as per sample. |
| 309 | Supply & Fix Exhaust fan louvers with shutter made of aluminium sheet of 0.5 mm thickness, and frames made out of mild steel, making good the distrubed surfaces in CM 1:4,including scafolding if any required to carry out the work in building of height up to 32 Meters complete in all respects the |
| 310 | Deployment of Technician for Fan checking, Fan Servicing / Safety Hook/ Pin including fixing of safety pin, nut, bolt etc. complete and entry in register duly signed by User/ Occupants.Techniia will Carry scheduled preventative maintenance checks as per details to be given by Site Executive. |
| 311 | M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable piano switch 5 Amps & refixing switch plate and testing complete all as directed.Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza |
| 312 | M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable fan regulator & refixing switch plate and testing complete all as directed.Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza |
| 313 | S&F,in repair PVC laminated ISI marked top cover 3 mm including cutting/drilling holes for mounting housing of switches, sockets, etc as per site requirement suitable for following sizes of sunken/TW board.4”x4” size |
| 314 | -Ditto- all as per Item No 312 above but 7”x4” size |
| 315 | -Ditto- all as per Item No 312 above but 8”x6” size |
| 316 | -Ditto- all as per Item No 312 above but 8”x10” size |
| 317 | -Ditto- all as per Item No 312 above but 10”x12” size |
| 318 | M & L taking down from positionexisting defective storage water heater 25 to 50 ltre storage Capacityfor carrying outrepairs work such as replacing worn out parts and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, painting with two coats of white synthetic enameled paint by spray paint complete all as specified and directed |
| 319 | Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed Make :- Racold/ Bajaj |
| 320 | Supply only non return valvechromium plated brass 15 mm dia heavy-duty all as specified and directedMake :- Racold/ Bajaj |
| 321 | Supply only indicator lamp for geyser red/green, round/square/rectangle as per site requirement 230 V AC all as specified and directed Make :- Mimic / AE |
| 322 | Supply only heating element 1500 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed Make :- Racold/ Bajaj |
| 323 | Supply only heating element 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater all as specified and directed Make :- Racold/ Bajaj |
| 324 | Supply only thermostat suitable for storage water heaters 25to 50 Ltrs capacity adjustabletype i.e.. 0 degree centigrade to 80 degree centigrade all as specified and directed Make :- Racold/ Bajaj |
| 325 | Supply and fix only plug top 3 pin 5 Amps capacityMake: Anchor ISI/LeaderISI/RIDER ISI |
| 326 | Supply and fix only plug top 3 pin 15/16 Amps capacityMake: Anchor ISI/LeaderISI/RIDER ISI |
| 327 | Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 0.75 sqmm 1100 volts grade all as specified and directed. Make Plaza, Havells |
| 328 | Supply and fix in replacement of copper water tank of 25 Ltrs capacity with and including necessary gasket packing, nuts, bolts, etc completeall as directed by Engr-in-Charge. |
| 329 | Fabricating, supply and fixingin replacement geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity forgeysers of any make as per the existing oneall as specified and directed |
| 330 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 331 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 332 | Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etcand making good disturbed surfaces of walls/ roof etc, complete all as specified and directed. |
| 333 | M & L forpoint wiring with PVCinsulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories andearth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressedsteel terminal boxes concealed in wall covered withlaminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screwsall as specified for one light / fan / bellpoint controlled by one switch in Thane and Mahul Stn |
| 334 | -Ditto- all as per item No 332 above but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches. |
| 335 | -Ditto- all as per item No 332 above but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board. |
| 336 | All as per item No. 332 above but wiring complete with 2.5Sqmm for 3 pin 15A socket multipurpose on independent board |
| 337 | S&F piano type5A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 338 | S&F flush type 2/3 pin combined shuttered type 5 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 339 | S&F flush type 2/3 pin combined flush type 5/15 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed. |
| 340 | S&F flush type15 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. |
| 341 | S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed |
| 342 | S & F Modularcover plate 4 modules |
| 343 | S & F Modularcover plate 6 modules |
| 344 | Supply and fixing condenser 2.5 MFD with PVC clamp. |
| 345 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and directed. Make :- ALMONARD / ORIENT |
| 346 | Supply and fix in replacement ofFRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable gkands as required at size and making connections all as specified and directed by Engineer –in –Charge.Make -National / Sintex |
| 347 | M&L for Multistandarded Copper Conductor cable of3 Core 1.5 Sq mmsize drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable all as Directed. Make :- Havells/ Polycab/Plaza/KEI |
| 348 | Supply and fix in replacement street light fittingsin street light poles/Buildings the fitting shall be of LED type 60 Wattscomplete with and including drivers, pressure die cast aluminium housing,prewired complete. Make-Havells/Crompton/Bajaj. |
| 349 | S&F in repairs LED batten Aluminium Extruded SmartLED 20W, 230 volts microwave sensor based electric fitting for save energy reduces the light intensity by 70% during non occupancy including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ BCLAB 20W LED PS/ PHILLIPS/ JAQUAR/ WIPRO |
| 350 | Comprehensive Repairs and maintenance of Fire alarm system inslalled at 31 WEU Thane,NCN Thane. The system comprises main Fire alaram Control Panel with battery back up, Manual Call Point (MCP), Electronic Hooter, Heat Cum Smoke Detector, Remote Response Indicators,installed at various locations complete, |
| 351 | Comprehensive Repairs and maintenance of Fire alarm system inslalled at TS Mahul. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete.Note for item 25 to 27 : a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommend the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alaram panel, Repeater Panel, Siren motor, replacing of broken Break glass. Cleaning of Smoke detectors.c) Testing the fire alram system including checking of each MCP and maintining serviceablity records on monthly basis.d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning. |
| 352 | Supply only PVC Insulation tape in RYB Colours of best adhesive quality and ISI approved of size 0.125mm x17mm x 6 Mtr .Make: Steelgrip,Anchor,Goldmetal |
| 353 | M& L for fabrication, installation of fire stand duly made out of angle iron frame of size 40x6 mm thick for canopy support of length 2 mtr and width 1.5 mtr sloping at middle portion, including canopy cover made out of MS sheet 3 mm thick with provision for hanging 6 Nos Fire buckets incl mounting hook etc complete duly painted with 2 coats of PO synthetic enamel paint redand grouting the supporting legs in PCC 1:3:6 at a location shown at site(i.e Thane and Mahul Stn) and comprising of the following:(a) GI fire bucket - 6 Nos.(b) Fire beater - 1 No.(c) Fire hook - 1 No.(d) ABC type fire Extinguisher of 5 Kg - 1 Nos(e) Foam typefire Extinguisher of 5 Kg - 1 Nos(f)CO2 type fire Extinguisher of 5 kg - 1 Nos(g) Excavation & earthwork as required in any strata. |
| 354 | M&L in repair rechargeable SMF batteries of BP-46,for 20Hours backup for microprocessor based intelligent control panel complete all as directed by Engineer-in-charge of following capacity at Thane /Mahul Stn:- Make:-Exide/Tata/Standerd Farukha(a). 12 Volts,40 AH |
| 355 | (b). 12 Volts,32 AH |
| 356 | (c). 12 Volts,7 AH |
| 357 | Supply and fix Automatic fire extinguisher ball medium size the weight of agent is not less than 1 kg but less than 1.8 kgs complete all as specified and directed at Thane and Mahul Stn. |
| 358 | Supply and fix in repair portable type electric heater blower type for use in electrical substations in rainy days to control moisture and prevents faultsof two heat settings 1000 Watts and 2000 Watts and automatic thermal safety cut out BIS approved ISI MarkedMake : Bajaj/Havells/Philips |
| 359 | Taking down and Refixing of Alluminium roof conductor/ down conductor including Air termination rod including provision of new insulator (procelain type) support, GI screw and all connected item complete all as specified and directed.Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter.ii) The raete is deemed to be inclusive for providing Procealin insulator, Galvanised screws, Plugsiii) PCC Block required shall be measure and paid under respective items |
| 360 | S & F in repairs aluminium earth strip as roof/down/earth ontunity conductors of size 25x3mm with saddles, insulators, screws, etc to / at any position / locationofsheds/ buildings of height up to 30 meter complete all as specified and directed by the Engineer-in-charge Note -i)The quoted rate is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter.ii) The rate is deemed to be inclusive of Procealin insulator, GI screws, Plugsiii) Space of insulator support shall not be more than 30 cm on roof / wall and 70 cm if insulator is placed over PCC block. |
| 361 | S & F in repairs air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary terminal base plate of not less than 3 mm, scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge |
| 362 | M & L in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw in replacement of the unserviceable. Including MS box made out of 3 mm thick shheet for fixing the block |
| 363 | M & L for pre-cast cement concreate block of size 0.15M x0.15M x0.15M for fixing of Aluminium striptype C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the coccrete block on terrace of bldgs of height up to 30 meter all as directed at site Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter. |
| 364 | Supply & fix in repairs of defective worn out GI funnel of 15 mm dia size suitable for GI/ Copper earthing pits complete all as specified and directed. |
| 365 | Supply only Industrial type commercial salt suitable for renewal of GI/ Copper earth plate complete all as specified and directed. |
| 366 | Supply only Industrial type Charcoal suitable for renewal of GI/ Copper earth plate complete all as specified and directed. |
| 367 | M & L in repairs/ replacement of broken old us PCC earth chamber alongwith PCC cover of size 600 x 600 mm complete all as specified and directed. |
| 368 | Note : A SUM OF RS 79,819.00 TOWARDS SCHEDULE OF CREDIT SHALL BE DEDUCTED TO ARRIVE THE CONTRACT SUM |