Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-10-2025 |
| 2 | 11-10-2025 | Corrigendum2 | Date | 18-10-2025 |
| 3 | 01-10-2025 | Corrigendum | BOQ | 17-10-2025 |
| Sl. No. | Item Description |
| 1 | M & L forpoint wiring with PVCinsulated unsheathed 1100 Volts grade single core FRLS multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories andearth continuity FRLS multistranded copper conductorcable size connected to common earth and earth dolly including 2 mm thick pressedsteel terminal boxes concealed in wall covered withlaminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screws including taking down u/s wiring, fittings, switch, sockets etc all as specified for the following:Note:- All points to be made in Hangers/Sheds, hight up to 10 Meters only.Make of Wire : KEI/ Polycab/ Benlo/ FinolexMake of Conduit: Pressfit/ Sudhakar(a)For one light, fan, call bell, point controlled by one switch. |
| 2 | (b)For one socket point controlled by one switch on same board |
| 3 | (c) One three pin switch socket 6 Amps out let on Same board |
| 4 | (d)For one5 Amp independent socket point controlled by one switch. |
| 5 | (e) One ceiling fan / exhaust fan point controlled by one switch |
| 6 | (f) One three pin switch socket 6 Amps out let on independent board |
| 7 | (g) One Bell point controlled by one push flush type switch |
| 8 | All as per item No 1 here-in-before but for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multi stranded 1100 volt grade cable as continuous earth lead. |
| 9 | M&L circuit wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5sqmm drawn in MS Steel conduitwith 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI markedof size not less than 20 mm dia in concealed/surfacewiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable wiring complete. Note : 1. M S Conduit/ PVC Conduitwill be measured and paid separately. 2. wiring in shed upto height of 6 mtr. 3. Three run of 1,5 Sqmm wire will be measured & paid as one unit.Make of Wire : KEI/ Polycab/ Benlo/ FinolexMake of Conduit: Pressfit/ Sudhakar |
| 10 | M&L sub main wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4Sqmm drawn in MS Steel conduitwith 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI markedof size not less than 20 mm dia in concealed/surfacewiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete.Note : 1. M S Conduitwill be measured and paid separately. 2.wiring in shed upto height of 6 mtr.3. Three run of 4 Sqmm wire will be measured & paid as one unit.Make of Wire : KEI/ Polycab/ Benlo/ FinolexMake of Conduit: Pressfit/ Sudhakar |
| 11 | M & L in repairs for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of damaged cable Glands, burnt cable lugs, bus bar link, connectors, damaged insulators, burnt copper cables, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as directed by Engg-in ChargeMake of paints : Nerolac/ Asian Paints/ Berger.Make of primer : Sheenlac/Asian/ Apcolite |
| 12 | Supply & Fix in repairs switch piano single poleflush type 5A,240 V one way complete.Make - Anchor/ Roma/ Havells |
| 13 | Supply & Fix in repairs Bell push flush type 5 amp, 250 Volts complete.Make - Anchor/ Roma/ Havells |
| 14 | Supply & Fix in repair/replacement Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed. |
| 15 | Supply & Fix in repairs switch socket combination 2 in 1 ,5Amps multipurpose flush type complete Make - Anchor/ Roma/ Havells |
| 16 | Supply & Fix in repairs switch socket combination 2 in 1,3 pin, 5 and 15 Amps flush type universal.Make - Anchor/ Roma/ Havells |
| 17 | S & F in repair/replacement of ceiling rose surface bakelite 65x50 mm with 3 terminals complete all as specified and directed. Make : Anchor / Vinay / Legrand / Maru |
| 18 | S&F,in replacement, electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete conforming/ ISI Marked all as specified.Make - Anchor/ Roma/ Havells |
| 19 | Supply and fix in repairs bell ding dong AC 230 V single pole.Make - Anchor/ Roma/ Havells |
| 20 | S & F in repairs Modular Socket 6 A, 2/3 Pin Combined,inclusive of modular cover plate & box as per combination of pointsMake - Anchor/ Roma/ Havells |
| 21 | S& F in repairs Modular Socket 6/16 A, 2/3 Pin Combined inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells |
| 22 | S & F in repairs Modular Switch single pole 1 Way 6 Amps inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells |
| 23 | S & F in repairs Modular Switch single pole 1 Way 16 Amps inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells |
| 24 | S&F in repairs ULTRON LED polycarbonate T8 tube 20 Watt with in built driver with metal heat sink, Single/ double sided connection, 230 volts including fixing arrangements and taking down old unserviceable tube rod complete all specified and directed. Make-:Crompton / Havells /Bajaj/Jaquar/Wipro |
| 25 | S&F in Repairs/ReplacementSurface and wall mounted batten suitable for LED tube 20-22 watts, 230 volts,including fixing mounting blocks 2 Nos, 1.5 sqmm 3 core PVC insulated copper conductor cable including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro |
| 26 | Supply and fix in repairs decorative recessed type LED light fitting 35/36 watt (size 2\"x2\") 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro |
| 27 | S&F in Repairs 36 W LED recessed full lit lminaire with glare free niform illumination with longer life and less maintainance 2x2 fitting mounted direct/indirect architectural luminaire including connecting 1.5 Sqmm white colour suitable for false ceiling fixing arrangement all as specified and directed in EIC. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS. |
| 28 | Supply and fixing in repair/replacement of of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including fixing mounting blocks 2 Nos, 15 mm MS conduit,including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directedMake : Bajaj / Wipro / Jaquar |
| 29 | Supply & fix in repairs LED Flood lightfittings 120 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/WiproNote : Fittings shall will be installed in Hangers/Sheds, height up to 10 Meters only and directed by Engr-in-Charge. |
| 30 | Supply & Fix in repairs MCCB DB TPN 4 Way double door prewired suitable for Triple Pole 125 A incomer MCCBwith the following acessories including taking down u/s DB - a) MCCB TP 125 A 25 KA 415 Volt - 1 Nosb) Bus bar, Din rail , Neutral linkMake - Havells/Indoasaian/Legrand/ABB/Schnider |
| 31 | Supply & Fix in repairs MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 32 | Supply & Fix in repairs MCB DB SPN 4 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 33 | Supply & Fix in repairs MCB DB SPN 8 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 34 | Supply & Fix in repairs MCB DB SPN 12 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 35 | Supply & Fix in repairs TPN DB 4 way 415 volts Double door, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 36 | S&F in repairs single pole and neutral enclosure with a two pin and earthand metal cladplug socket complete with one single pole MCB 20 Amp 240 Volts including taking down old u/s complete all as specified and directed. Make - Indoasain/Legrand/Havells |
| 37 | M&L in repairs for MCB SP, 240 volt, 5 to 32 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed.Make - Indo Asian/Legrand/ ABB/Schnider/Havells |
| 38 | M&L in repairs for MCB SPN, 240 volt, 40 to 63 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed.Make - Indo Asian/Legrand/ABB/Schnider/Havells |
| 39 | M&L in repairs for MCB TPN, 240 volt, 40 to 100 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed. Make - Indo Asian/Legrand/ABB/Schnider/Havells |
| 40 | Renewal of broken/wornout earth pit including M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long(100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications completeall as directed by Engineer-in-Charge.(a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns .Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm,External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms,Recommended for normal soil conditions. Conforms to IS : 3043 – 1987.(c)Installation of earthing with bore well machine complete for bore exceeding upto 4.5 meter below ground level complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F in repairs 20x3mm copper stripall as directed including welding brazing and taking down of old copper strips as required at site |
| 42 | S&F GI 32x6 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn inpipe, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge |
| 43 | S & F in repairs copper 20x3 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in conuit / pipe or fixed to poles or any other indicated situation for earthing, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge |
| 44 | Taking down old unserviceable High bay, Mid Bay, Flame Proof light fittings from walls/Builings/Sheds/Ceilingheight up to 10 Meter for repairs and replacement ofburnt/worn out accessories and refixing the same in existing position including testing of fittings after repair, testing of connected wiring complete all as directed by Engineer in charge . Note :- (a) T & P, Ladder for any height etc are deemed to be included in the quoted rate.(iii) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contrcat period and the defect shall be rectified on the same day(iii)A penal recovery of Rs 500 Per Day Per Complaint for not attening the compalint will be recovered |
| 45 | Supply and fixing Post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including removing old unsv lights complete. Make:- Bajaj/ Havells / Benlo/ Crompton/ Jaguar/ Wipro |
| 46 | Supply and fixing Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including taking down old u/s light fitting complete. Make:- Havell\"s/ Crompton/ Jaguar/ wipro/ Bajaj/ Benlo |
| 47 | S&Fix in replacement Flameproof wall mounted outdoor type double door LT Panel made out of 3 mm thick CRCA Sheet, the panel shall be provided with flame proof MCB DB made out of Cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade, with 1 No cable entry for incoming cable and three Nos cable entry for out going circuits with and including cable gland and stopping plug, 1 No MCB SPN 32 Amp as incoming and 3 Nos MCB SP6 Amps for out going connections IP 65 protection as per IS 2147/1962. The panel shall be powder coated, front openable and locakable with key and shall be fabricated from CPRI approved sample manufacturer including taking down old u/s Panel complete all as specified and directed. Make- Sudhir /Flexpro /Baliga /crompton greeves/ Shyam Switch GearNote - The contractor shall submit the Layout Drawing of Panel and got approved by GE before the panel fabrication |
| 48 | Supply and Fix in repairs CIMFR certified LED flame proof well glass light fitting 60 watts , with driver & LED, IP 65 protection, including connecting up with three core flexible multi strand copper conductor of 1.5 Sqmm, with flexible metal conduit, including including fabricating red oxide coated brackets made out of MS angles/MS flat for fixing the fitting up to one meter below permenent ceiling, including anchor fastners, nut, bolts, hooks, chainetc including taking down old u/s fitting. The Fitting Shall Conform toMake : Crompton/ Shyam Switch Gear /Bajaj / SudhirNote : (a) Fittings shall will be installed in Hangers/Sheds, hight up to 6 Meters only and directed by Engr-in-Charge.(b) T & P, Ladder for any height etc are deemed to be included in the quoted rate. |
| 49 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60Amp suitable for single phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T / HPL / ABB/ Benlo |
| 50 | S&F air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary terminal base plate of thickness not less than 4 mm, scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge |
| 51 | M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw in replacement of the unserviceable. Including MS box made out of 3 mm thick shheet for fixing the block complete all as specified and directed. |
| 52 | S & F Aluminium strip 25 X 3.15 mm with saddles and supporting insulator fixed with non-corosive screw/nut, bolt etc. for roof conductors and down conductors above ground. |
| 53 | M&L for pre-cast cement concreate block of size 0.15M x0.15M x0.15M for fixing of Aluminium striptype C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the coccrete block on terrace of bldgs of height up to 30 meter all as directed at site Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter. |
| 54 | Supply and fix in repairs hi wall split unitsindoor complete with cordless remote control unit and with in built air ioniser and plasma filter forbetter indoor air quality including taking down old u/s indoor AC unit of capacity 2 Ton electric driven single phase 230 Volt complete all as specified and directed.Make as per sample |
| 55 | -ditto- all as per item No 8 above but for 1.5 Ton capacity complete all as specified and directed.Make as per sample |
| 56 | Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 Ton including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed.Make as per sample |
| 57 | -ditto- all as per item No 10 above but for 1.5 Ton capacity complete all as specified and directed.Make as per sample |
| 58 | Material and labour for servicing of A/C window type or split type A/C, tower ACof capacity1.5/2/2.5 TRincluding washing with sodash the cooling coil/condensor coil base body drying with air blowerchecking complete wiring testing and re-installing in situ and testing the unit. |
| 59 | M & L for dismentling unserviceablecompressor from the window type AC, Split type A/C 1.5 TR/ 2.0 TR capacity from any location , supply and fix new hermatically sealed compressor unit , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testingall as directed and specified.Make : Voltas/Carrier/Kirloskar /bluestarNote : (i)Job including removing A/C from any site/height/location(ii)Transporting A/C unit to repair workshop and back to site(iii) Loading/unloading etc |
| 60 | Supply and fixing in repair of LED Drivers for street light/garden lights/highbay lights/flood lights/post top lantern from 25 Watt to 150 Watt as per sample |
| 61 | S & F in repair/replacement of LED Driver 60 Watt Suitable for street light fitting, Security light and flood light. Make :- Crompton/ Havells /Bajaj |
| 62 | S & F in repair/replacement of LED Driver 30/35 Watts Suitable for street light fitting, Security light and flood light. Make :- Crompton/ Havells /Bajaj |
| 63 | Supply and fixing in repairs ceiling fans complete with blades,down rods,electronic regulator and accessories,230V,1200mm sweep Min air delivery 210CFMwith service value 6.00 BEE five star rated with brushless direct current motor.including taking down of existing fan and deposit in MES Stores.Make: Bajaj Energos 26,Orient,Havells,Almonard. |
| 64 | Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron strip 32 X 6 mm dia by means of bolts, washers, watering pipe 20mm dia, medium gradeGI pipe, with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fittingas protection pipe for strip from earthing plate electrode to test point including concrete pit in PCC (1:3:6) type C-Iand pre-caste RCC 1:2:4 type B-1 cover with 8mm dia MS handle. Charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as show in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed. Note: (1) 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately(2) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate.(4) The Execavation shall be done manually by man power, the quoted rate is inclusive of digging out roots.(5) The qoted rate is deemed to be inclusive of removal of the excess material from the work site. |
| 65 | M & L for earthing in repairs complete with Copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materils |
| 66 | M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deepbelow ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed. |
| 67 | Excavation in trenches not exc 1.5 mtr wide & n.exc 10 sqm cm on plan and not exc 1.5 mtr in depth and getting out in soft / loose soil |
| 68 | Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil. |
| 69 | Removing the excavated materials not exc 50mtr and depositingwhere directed at a level not exceeding 1.5 mtr above the staring point all as directed by Engr - in- Charge. |
| 70 | M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by EIC.Note : Sand after punning down will be measured |
| 71 | Supply and laying in repairs precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.. Make - Methab Indore Tiles or Conforming to IS Marked. |
| 72 | Laying only un-reinforced precast concrete cable cover class LV, type-I, flate size 250mm x 150mm x 40mm laid cable cover obtained shall be reused. |
| 73 | Supply and lay in repairs cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size:3.5 core 25 Sqmm including taking down of old u/s cable complete all specified and directed.Note - Excavation and earth work will be mesured and paid seprately |
| 74 | M & L in repairs for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge. |
| 75 | M & L in repairs for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge. |
| 76 | M & L in repairs spray painting inside, outside complete tothe LT panel boards outdoor type of size not exceeding 2.0 Mtrwidth 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. Make: PAINT: ASIAN/ NEROLAC/ BERGER |
| 77 | S & F in replacement of GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x 5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge. Make: PAINT: TATA/ JINDAL/ ZENITH |
| 78 | S & F in repairs/ replacement of GI steel tubing medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cable protectionincluding necessary fittings , clamps for supports, etc all as directed by Engineer in charge. Make- TATA/ JINDAL/ ZENITH/ SURYA |
| 79 | M & L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge.. |
| 80 | M&L for cutting existing road/hard standing not exc 30x60 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well rammaing wateringfinish suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top\", including removal of surplase soil all as directed. |
| 81 | M&L for cutting existing road/hard standing not exceed 45x60 cm in wide and depth getting out excavated material for laying of cable returning filling & well ramming watering finish surface 10 cm from top including provision of PCC 1:2:4 for repairing, including removal of surplase soil all as directed. |
| 82 | S&F of HDPE pipe 50 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etc complete all as specified and directed. Make: PLASTO / PRECISION / SUPREME / SUDHAKAR / DUPLON / TIRUPATI / FINOLEX |
| 83 | M & L in repairs MCCBs 3 Pole 250 Amps,25 KA including connecting up electrically with suitable lugs glands spreader links etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELL\"S/ C&S/ INDOASIAN |
| 84 | M & L in repairs MCCBs 3 Pole 200 Amps,25 KA including connecting up electrically with suitable lugsglands spreader links etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELL\"S/ C&S/ INDOASIAN |
| 85 | M&L in repairs MCCBs 3 Pole 100 Amps,16 KA including connecting up electrically with suitable lugsglands spreader links etc all as specified and directed by Engineer –in –Charge. Make: L&T/ LEGRAND/ HAVELLS/ C&S/ INDOASIAN |
| 86 | Supply and Fix in repairs MCCB 100 Amps 25 KA, 4 pole, 415 Volt IN SHEET STEEL ENCLOSUREin open construction, panel mounted 0n wall with base plate for mounting in panel, including taking down of old MCCB with enclosure and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd/ C&S/ L&T |
| 87 | M&L in repairs MCCB 63 Amp, 4 Pole,16 KA including connecting up electrically with suitable lugsglands spreader links etc all as specified and directed by Engineer –in –Charge. Make: HAVELL\"S/ SCHINDER/ LEGRAND/ INDOASIAN |
| 88 | M&Lin repairs for Astronomical analog 24 Hrs, 240 V FM1 Quartz type daily Timer switch for controlling street lights contactors all as specified and directed by Engineer –in –Charge.Make : L & T/ Indo Asian/ C&S |
| 89 | S&F in repair of building Security lightfitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make : Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS. |
| 90 | M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using comutrised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site.Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately.(ii) Cable joint will be measured and paid seperetely.(iii) Additional lenth of cable required at site for jointing will be measured and paid seperately. |
| 91 | Supply install, in repairs Powder coated LTkiosk cubical indoor type Channel mounted compartmentalized in construction allConfirming to IS 8623 Part 1 1993CPRI approved factory as per CA fabricatedmade out of 2 mm thick CRCA sheet & suitable size to accomodateall accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, ContactorsThe TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. Thecubicle shallhaveabottomchannel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm of A detachable predrilled gland plateof thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wireand consisting the following, including taking down of old unsv panel after disconnecting Existing cables, Existing energy meters and re fixing the energy meters at new panel & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts.a) Electrolytic Copper bus bar 100 Amps for 3 phase and Half for Neutralb) MCCB FP 63 Amps 415 Volt25 KA - 1 Nosc) MCB TPN 40 Amps, 16 KA 415 Volts- 1 Nosd) MCB SPN 40 Amps, 10 KA 230 Volts - 7 Nose) Digital Ameter, 0-100 Amps - 01 No, f) Digital Volt Meter, 0-415 Volts, 3 Phase - 01 Nog) Space for Fixing 7 Nos of Single Phase Energy Meter of Capacity 40 Amps,h) LED based RYB Indicators - 1 Set j) Selector switch for voltmeter and Ammeter.- 01 nos. |
| 92 | -ditto all as per item No 24 above but with the following acessories:-a) Electrolytic Copper bus bar 100 Amps for 3 phase and Half for Neutralb) MCCB FP 40 Amps 415 Volt25 KA - 1 Nosc) MCB TPN 40 Amps, 25 KA 415 Volts- 1 Nosd) MCB SPN 40 Amps, 10 KA 230 Volts - 5 Nose) Digital Ameter, 0-100 Amps - 01 No,f) Digital Volt Meter, 0-415 Volts, 3 Phase - 01 Nog) Space for Fixing 5 Nos of Single Phase Energy Meter of Capacity 40 Amps,h) LED based RYB Indicators - 1 Set j) Selector switch for voltmeter and Ammeter.- 01 nos. |
| 93 | Supply install, in repair Powder coated LT kiosk cubical outdoor type (double door openable) Channel mounted compartmentalized in construction allConfirming to IS 8623 Part 1 1993CPRI approved factory as per CA fabricatedmade out of 3 mm thick CRCA sheet & suitable size to accomodateall accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, ContactorsThe TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. Thecubicle shallhaveabottomchannel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm of A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wireand consisting the following, including taking down of old unsv panel after disconnecting Existing cables, Existing energy meters and re fixing the energy meters at new panel & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts.:a) Electrolytic Copper bus bar 600 Amps for 3 phase and Half for Neutralb) MCCB FP 400 Amps 415 Volt36 KA - 1 Nosb) MCCB FP 250 Amps 415 Volt36 KA - 1 Nosb) MCCB FP 100 Amps 415 Volt16 KA - 2 Nosb) MCCB FP 63 Amps 415 Volt16 KA - 2 Nosc) MCB TPN 40 Amps, 16 KA 415 Volts- 2 Nosd) MCB SPN 32 Amps, 10 KA 230 Volts - 1 Nose) Digital Ameter, 0-100 Amps -01 No, f) Digital Volt Meter, 0-415 Volts, 3 Phase - 01 Nog) LED based RYB Indicators - 1 Set h) Selector switch for voltmeter and Ammeter.- 01 nos and Timer.j) Timer switches 415 V three phase of 20 Amps rating with contactor-2 No\"s |
| 94 | -ditto all as per item No 26 above but with the following acessories:-a) Electrolytic Copper bus bar 300 Amps for 3 phase and Half for Neutralb) MCCB FP 200 Amps 415 Volt25 KA - 1 Nosc) MCB TPN 100 Amps, 16 KA 415 Volts- 3 Nosd) MCB SPN 32 Amps, 10 KA 230 Volts - 2 Nose) Digital Ameter, 0-100 Amps- 01 No, f) Digital Volt Meter, 0-415 Volts, 3 Phase - 01 Nog) LED based RYB Indicators - 1 Set h) Selector switch for voltmeter and Ammeter.- 01 nos and Timer.j) Timer switches 415 V three phase of 20 Amps rating with contactor-2 No\"s |
| 95 | Supply, install,in repair/ renewal feeder piller box outdoor type, IP-54 protection CPRI approved, factory fabricated, cubical panel wall mounted, self supported, free standing type, made out of 3.15m thick CRCA sheet with locking arragement, suitable for 3 phase, 4 wire, 415 volt, 50HZ, AC supply including suitable size copper conductor control wiring and powder coating with connecting the cables with necessary cable glands, lugs etc proper arrangement for veritilation complete with and including the following accessories :-(i) Electrolytic Copper bus bar Phases & Half for Neutral for 150 Amps- 01 set(a) MCCB 4 pole 25 KA 100 Amp - 1 Nos(b) MCB TPN 40 Amp 10 KA- 01 Nos(c) MCB SPN 32 Amp 10 KA - 01 Nos |
| 96 | Supply and Fix in repairs Change Over FP 250 Amps 415 Volt IN SHEET STEEL ENCLOSUREin open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/ Havells/ Standerd/ C&S/ L&T |
| 97 | Suppli and fix in repairs Halogen lamp with fixture complete of capacity 500/ 1000 watt operating on 230v, single phase, AC, 50 Hz supply complete all as specified and directed. |
| 98 | M&L for reinforced cement concrete nominal mix M-20(using 20 mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed.(Note - Reinforcement and form work will be measured and paid separately). |
| 99 | Supply and Laying in repair/replacementor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core in trenches,along the wallincluding necessary connection and providing cable lugs as required includingdisconnection/taking down of existing unsvcable all as specified.Make: Polycab / KEI / Anchor (Panasonic) / Gloster |
| 100 | Supply and Laying in repair/replacementor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 4 core in trenches,along the wallincluding necessary connection and providing cable lugs as required includingdisconnection/taking down of existing unsvcable all as specified. Make: Polycab / KEI / Anchor (Panasonic) / Gloster |
| 101 | Supply and Laying in repair/replacementor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 4 Sqmm 3 core in trenches,along the wallincluding necessary connection and providing cable lugs as required includingdisconnection/taking down of existing unsvcable all as specified. Make: Polycab / KEI / Anchor (Panasonic) / Gloster |
| 102 | M&L in repairs/replacement of submain wiring with ISI-marked 1.1 kV grade, single-core, HR-FR (Heat Resistant, Flame Retardant) flexible copper conductor cable conforming to IS:694-1990 and IS:5831-1984, Type ‘C’, HR 85°C + FR, for phase, neutral, and earth continuity conductors, drawn through not less than 20 mm NB UPVC medium-grade surface/recessed conduit or casing-capping conforming to IS:9537 (Part-3), colour-coded as per IS:732-1989, including saddles, clamps, bolts, and nuts, for interconnection of looping boxes, street light fittings, post-top lanterns, sockets, or DB-to-DB connections, and making good disturbed wall/ceiling/floor surfaces, complete all as specified and directed; Note: One run of phase, one run of neutral, one run of earth continuity conductor, and one run of conduit shall be measured as one length.(a) 2 X 1.5 mm2 + 1 X 1.5 mm2 earth wire |
| 103 | (b) 2 X 2.5 mm2 + 1 X 2.5 mm2 earth wire |
| 104 | (c) 2 X 4.0 mm2 + 1 X 4.0 mm2 earth wire |
| 105 | (d) 2 X 6.0 mm2 + 1 X 4.0 mm2 earth wire |
| 106 | S & Fin repair/replacement of decorative 15 Watts LED (Ruby clear type, IP-65) New generation, post Top energy saving, environmental friendly, long life aesthetically disigned with symmetical light distribution, spun aluminium landscape luminaire with high power LED\"s as light source including mounting arrangementupto 2.00 mtr height with medium grade GI tubing of suitable dia alongwith MS angle bracket/framed covers including clamps, bolts nuts, painting by aluminium paint complete all as specified and dierected by Engr-in-Charge.The fitting shalll conform to cat No - RUBYMINIPT15WLED757PSYMTOPC of Havells or Equivalent from Crompton/Bajaj. |
| 107 | Supply & Fix repair/replacement of 8 watts LED(CONE-IP 65) Bollard Garden light fittings Cone series acts as an imposing street furniture.The elegant yet minimalistic design acts a silent observer and giving light, diffuser at the upper portion adds functional value into landscape environment.including driver, nuts, bolt, washers, base plate complete , the Fitting Shall Conform to Cat No - CONEBLSWLED857PSYMTOPCM of Havells or Equivalent from Bajaj/Crompton |
| 108 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1616B /National/Sintax |
| 109 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 130 x 180 x 77mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1010B /National/Sintax |
| 110 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel |
| 111 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 130 x 180 x 77mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel |
| 112 | Supply and fix in repair of FRPCable junction box weather proof\" (with knockouts for cable entry) box of size 300 x 200 x 105 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelcomplete fitted with terminal connector block bakelite 4 way of 63 Amps – 04 Nos Rating with shorting strip copper, fitted with one Nos of MCB SP 06 Amps 240 Volts for termination of incoming and outgoing cables, local connection to fittings including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel /National/Sintax |
| 113 | S & F in repair of security light fitting/Building security lightLED type 35 watts, THD<10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc including taking out old u/s security lights all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS. |
| 114 | S & F in repair of security light fitting/Building security lightLED type 60 watts, THD<10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc including taking out old u/s security lights all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS. |
| 115 | Supply & fix in repairs LED Floodlight with system luminous efficacy of 120lm/w, protected to IP66, with front toughened glass of 150 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/WiproNote : Fittings shall will be installed in brackets of pole in iron structure fitted on pole |
| 116 | S & F in repair/replacement of 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including fixing mounting blocks 2 Nos, 15 mm MS conduit,electrical connection with 3 core flexible Copper conductor cable of 1.5sqmm size from ceiling rose to the fixture complete all as specified and directed.Make : Bajaj / Wipro / Jaquar |
| 117 | S & F in repair/replacement of 35/36W recessed type 2*2 LED based having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95,LED lamp suitable for roof ceiling including fixing mounting blocks 2 Nos, 15 mm MS conduit,electrical connection with 3 core flexible Copper conductor cable of 1.5sqmm size from ceiling rose to the fixture complete all as specified and directed.Make : Bajaj / Wipro / Jaquar |
| 118 | S & F in repair/replacement of 36 W ceiling surface light of size (2x2ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, Including electrical connection with 3 core flexible copper conductor cable of 1.5 sqmm appropriate size from ceiling rose to the fixture complete all as specified and directed.cat / model No BCTBLS 43 ZT WH of bajaj or equivalent inwipro / Jaquar/ Bajaj |
| 119 | Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers andconnectors after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LEDwill be measured and paid separately |
| 120 | M&L for testing of existing earth electrode/earthing system in accordance with IS:3043–2018 using a calibrated digital/analogue earth tester, recording and submission of results to Engineer-in-Charge, including pre-conditioning by watering each pit with 30 L of water mixed with 20 kg salt one day prior to testing, thorough cleaning and preparation of the earth pit/cover by wire brushing and removal of dirt, rust, and loose paint, application of one coat of red oxide primer followed by one coat of synthetic enamel paint of approved shade, and stencilling of earthing identification details and latest measured resistance value (in ohms) in contrasting colour, all tools, instruments, consumables, and labour deemed included in quoted rate, complete all as specified and directed. |
| 121 | M&Lin repairs for 24 Hrs240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE Location : TS Mahul |
| 122 | M&L for fabricating and fixing MS angle iron in replacement of size 25x25x5MM,flat iron and brackets etc for fabrications for fixing flood light in wall ,poleincluding nuts,bolts,washers,welding to shapes for fabrication of structure to fix flood light including necessary cutting/jointing/welding with one coat of red oxide and two coats of synthetic enamel paints complete all as specified and directed. |
| 123 | Material and labour in repairs for earth continuity conductor or main earthing lead fixed to wall with suitable insulator on batten or recess or chasis or buried in ground or drawn in conduit / pipe or any other indicated situation for and connecting to test point terminal block with GI strip of size 32 x 6 mm including taking out old u/s earth continuity conductor complete,all as specified and directed. |
| 124 | Supply only PVC Electrical Insulation Tapeof superior quality, self-adhesive, fire-retardant PVC electrical insulation tape of size 1.7 cm (width) x 6 m (length) x 0.125 mm (thickness), providing excellent grip and durability supplied in pack of 30 rolls complete all as directed by Engineer-in-Charge. Make :Pidilite Steelgrip.Location : TS Mahul |
| 125 | S&F in repair/replacement of modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 126 | S&F in repair/replacement of modular type6A Two way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 127 | S&F in repair/replacement of modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 128 | S&Fin repair/replacement of modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 129 | S&F in repair/replacement of modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed. Location : TS Mahul, Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 130 | S & F in repair/replacement ofmodular type 120W step fan regulator, 2 module, single pole one way. 230 volts ISI marked and connecting up complete. Location : TS Mahul Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 131 | S & F in repair/replacement of Modularcover plate 12 modules confirming to IS : 14772: 2000 all as specified and as directed.Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) Location : TS Mahul |
| 132 | S & F in repair/replacement of Modularcover plate 8 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 133 | S & F in repair/replacement of in repair/replacement of Modularcover plate 6 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 134 | S & F in repair/replacement of Modularcover plate 4 modules confirming to IS : 14772: 2000 all as specified and as directed.Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 135 | S & F in repair/replacement of Modularcover plate 3 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 136 | S & F in repair/replacement of Modularcover plate 2 modules confirming to IS : 14772: 2000 all as specified and as directed. Location : TS MahulMake: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) |
| 137 | S & F in repair/replacement of Modularcover plate 1 modules confirming to IS : 14772: 2000 all as specified and as directed.Make: Legrand/ Havell\"s (Crabtree)/ Schneider/ Anchor (Roma) Location : TS Mahul |
| 138 | Supply and fixing in repair/replacement16 Ampere, 3-pin plug top, heavy-duty, ISI-marked, moulded type, suitable for operation on 240V single-phase AC supply. The plug top shall be made of high-grade, fire-retardant, impact-resistant polycarbonate/ABS body with brass pins and terminals for superior conductivity. The design shall include a robust gripping arrangement, strain-relief for cable entry, and ensure firm contact engagement with matching sockets. Location : TS Mahul Make: Anchor / Havells / Legrand / Schneider or equivalent. |
| 139 | Supply and fixing in repair/replacement of Universal (UNI) switch socket combined unit, factory-assembled, modular type, suitable for operation on 240V, 50Hz, single-phase AC supply. The unit shall consist of one universal 6A/16A 3-pin socket and a modular switch (6/16A) housed in a suitable front plate with flush mounting box, made of high-strength, fire-retardant, UV-stabilized polycarbonate/ABS material. The unit shall be ISI-marked, conforming to IS:1293/IS:3854, with brass terminals and silver-plated contacts for reliable conductivity. Complete installation including interconnections, earthing, and fixing accessories. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 140 | Supply and fixing in repair/replacement of 6 Ampere, one-way, non-modular switch, piano-type, ISI-marked, suitable for 240V, 50Hz single-phase AC supply. The switch shall be made of high-quality, fire-retardant, shockproof thermosetting material with brass terminals and silver-plated contacts for smooth operation and long service life. Complete with necessary accessories for surface or flush mounting. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 141 | Supply and fixing in repair/replacementof 16 Ampere, combined switch and 3-pin socket unit, non-modular type, ISI-marked, suitable for 240V, 50Hz single-phase AC supply. The unit shall be made of heavy-duty, fire-retardant, shockproof thermosetting material with brass terminals and silver-plated contacts, complete with necessary mounting box, front plate, and fixing accessories. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 142 | Supply and fixing in repair/replacementof surface mounting box suitable for accommodating 6-module (6M) modular switches, sockets, and accessories, made of high-quality, fire-retardant, shockproof, UV-stabilized polycarbonate/ABS material. The box shall have adequate space for wiring, pre-punched knockouts for conduit entry, and provision for secure mounting on wall surfaces. It shall be complete with all fixing accessories and conform to relevant IS standards. Location : TS MahulMake: Anchor / Havells / Legrand / Schneider/ Havell\"s (Crabtree) |
| 143 | Supply & fix in repair/replacement of Heavy Duty metallic Exhaust fan of sweep 300 mm sweep with frames, blades, mounting anchor fasteners, aluminium louvers made of aluminium sheet of 0.5 mm thickness, rovision of three core 1.5 Sqmm copper cable from celling rose to fan, making opening of required in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4, Including scafolding if any required to cary out the work in building of height up to 20 Meters complete in all respects the Exhaust Fan Shall Conform to Cat no EXHD380-4-1 of Crompton or Equivalent from Bajaj/GE. Make :- ALMONARD / ORIENT / USHA / BAJAJ / CROMPTON / HAVELLS Note : Unserviceable ceiling fans shall be deposit to MES store. Location : TS Mahul |
| 144 | Supply and fix in repair/replacement of exhaust fan made of sturdy Engineering rust proof ABS Plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed. Make :- ALMONARD / ORIENT / Bajaj / Havells Location : TS Mahul |
| 145 | Supply and delivery in repair/replacement of 2.5 MFD capacitor, suitable for single-phase AC applications, rated for 440V AC, 50Hz. The capacitor shall be metallized polypropylene (MPP) type, self-healing, oil-free, hermetically sealed in a cylindrical aluminium or plastic canister, and equipped with PVC-insulated flexible lead wires for easy connection. It shall be designed for continuous duty in fans, pumps, and motor-start/run applications, conforming to IS 2993/IEC standards. Location : TS MahulMake: L&T / Havells / EPCOS / Crompton / Equivalent. |
| 146 | Supply and fixing in replacement of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, High Speed with service value 6.00 minimum BEE 5 star rated with brushless direct current motor (BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge.Make : Bajaj (Energos 28) / Orient (Falcon 400) / Havell’s (Efficiencia Neo BLDC 26W) Note Location : TS Mahul : Unserviceable ceiling fans shall be deposit to MES store. |
| 147 | Supply and fixing in repair/replacementof Hylam (Bakelite) sheet back panel, size 14\" x 6\", suitable for electrical switchboard mounting. The sheet shall be made of high-grade, industrial-quality phenolic laminated material, white, heat-resistant, shockproof, moisture-resistant, and durable, providing a strong insulating base for switchgear and fittings. Sheet shall be unpolished/unfinished and supplied complete with drilling and cutting as required for installation. Location : TS MahulMake: Hylam / Formica / Equivalent ISI-marked brand. |
| 148 | Dismantling only in repairs of PCC foundation / pole coping from ground level all as per specified. |
| 149 | M & L in repairs for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed. |
| 150 | -Ditto- all as per item No 9 above here-in-before but 10 Sqmm 4 Core complete all as specified & directed. Make: Polycab/ Havell\"s/ KEI/ Gloster/ Universal |
| 151 | M&L for taking down old unsv and supply & lay 3Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit with necessary saddle, clamps, bolts & nuts,all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / KEI / HAVELLS/ BENLO |
| 152 | Supply and fix in repairs flood lightluminaire with polycarbonate optics pressure die cast housing IP 66 ingress protection, 4 KV in-built and 10 KV external SPD, having efficiency not less than or equal to 150 lm/watt, CCT 5700oKin buildings etc the fitting shall be of LED type 150 Wattscomplete all as specified. Make : Bajaj/ Jaguar/ Wipro/ Benlo/ Havells/ Crompton |
| 153 | S&F in repair of building Security lightfitting made up of pressure die cast alluminium body with mid power 60 Watt LEDluminaire, with IP 66 protection, 4 KV in-built and 10 KV external largeprotection having luminuous efficiencies not less than 110 lm/watt CCT 5700K as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make : Bajaj/ Wipro / Havells /Jaguar /Benlo |
| 154 | Dismantling complete old Bolard light fitting and Supply & Fix 8/9 watts LED Bollard Garden light fittings with efficient high outputLED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation0.3 Meter x 0.3 Meter x 0.3 Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry complete. Make:- Havells / Bajaj/ Crompton/ Jaguar/ Benlo/ Wipro |
| 155 | M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 25 to 50 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M |
| 156 | M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 120 to 185 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M |
| 157 | S & F in repair Analog Time switch astronomical type FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY). Make L&T/ C&S |
| 158 | S & F in repair 3 Pole power contactor MNX-18 of coil voltage 415 VoltsMake - L&T/ C&S |
| 159 | S & F in repair spare coil for MNX-18 3 pole power contactor of 415 voltsMake - L&T/ C&S |
| 160 | S&F Motion Sensor Switch consisting of sensitivity detector with wide detection field, integrated circuit, having automatism(day & night), convenience, safety, saving-energy and practicality functions of power indication and detection indication. Operation on receiving human motion infrared rays on entering the detection field, comprising of following features and specifications as give under :-Specification:(a) Power Source: 110 -220V/AC(b) Detection Range: 360°(c) Power Frequency: 50Hz (d) Working Temperature: -20°C~+40°C (e) Ambient Light: 3-2000LUX (adjustable) (f) Working Humidity: <93%(g) RH Time-Delay: min: 10sec±3sec Max: 7min±2min (h) Installation Height: 2.2-4m (j) Power Consumption: 0.45W (work) 0.1W (static)(k) Rated Load: 1200W (incandescent lamp) 300W (energy-saving lamp)(l) Detection Motion Speed: 0.6 ~1.5m/s (m) Detection Distance: 6m max (24°C) Function: (a) Identification ofday and night: (b) Consumer adjustable work ambient light.(c) Work in the daytime and at night are adjusted on the \"sun\" position (max). (d) Ability to work in the ambient light less than 3LUX on adjusted on the \"moon\" position (min).(e)Time-Delay is added continually on receipt of second induction signals after the first induction(f) Having compute time once more on the basic of the first time-delay rest. (g) Adjustable time delay having minimum time is 10sec±3sec. & maximum is 7min±2min as per requirement complete all as specified & directed.Make: Anchor (Panasonic)/ Impact (Honeywell)/ or equivalent. |
| 161 | S&F The Motion Sensor Switch adopts good sensitivity detector, integrated circuit. It gathers automatism, convenience, safety, saving-energy and practicality functions. The wide detection field is consisting of detectors. It works by receiving human motion infrared rays.When one enters the detection field, it can start the load at once and identify automatically day and night.Its installation is very convenient and its using is very wide. It has functions of power indication and the detection indication. SPECIFICATION: Power Source: 110 -220V/AC Detection Range: 360° Power Frequency: 50Hz Working Temperature: -20°C~+40°C Ambient Light: 3-2000LUX (adjustable) Working Humidity: <93%RH Time-Delay: min: 10sec±3sec Max: 7min±2min Installation Height: 2.2-4m Power Consumption: 0.45W (work) 0.1W (static) Rated Load: 1200W (incandescent lamp) 300W (energy-saving lamp) Detection Motion Speed: 0.6 ~1.5m/s Detection Distance: 6m max (24°C) FUNCTION: 1.Can identify day and night: The consumer can adjust work ambient light. It can work in the daytime and at night when it is adjusted on the \"sun\" position (max). It can work in the ambient light less than 3LUX when it is adjusted on the \"moon\" position (min). As for the adjustment pattern, please refer to the testing pattern. 2.Time-Delay is added continually: When it receives the second induction signals after the first induction, it will compute time once more on the basic of the first time-delay rest. 3.Time-Delay is adjustable. It can be set according to the consumer\"s desire. The minimum time is 10sec±3sec. The maximum is 7min±2min |
| 162 | Supply & fix in repairs LED Highbay light fittings 150 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. Make :- Crompton / Havells /Bajaj Note : Fittings shall will be installed in Hangers/Sheds, height up to 10 Meters only and directed by Engr-in-Charge. |
| 163 | Supply & fix in repairs very high efficiency round LED Highbay light fittings 150 Watt in PDC housing, IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. Make :- Crompton / Havells /Bajaj.Note : Fittings shall will be installed in Hangers/Sheds, hight up to 10 Meters only and directed by Engr-in-Charge. |
| 164 | Supply and fixing in repair/replacementof Hylam (Bakelite) sheet back panel, size 14\" x 6\", suitable for electrical switchboard mounting. The sheet shall be made of high-grade, industrial-quality phenolic laminated material, white, heat-resistant, shockproof, moisture-resistant, and durable, providing a strong insulating base for switchgear and fittings. Sheet shall be unpolished/unfinished and supplied complete with drilling and cutting as required for installation. Make: Hylam / Formica / Equivalent ISI-marked brand. |
| 165 | M & L for Taking down and Refixing the aluminium/copper strip of any size from any position / location ofsheds/ buildings of height up to 30 meter &laid as roof conductor, down conductor, earth contunity conductoor same after straightning the conductor/removal of bends, including replacing the old strips, insulators with new one and saddles all as directed at site Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter.ii) The raete is deemed to be inclusive for providing Procealin insulator, screws, Plugsiii) PCC Block required shall be measure and paid under respective items iv) Span of PCC Block support shall be kept at 70 cm.v) Span of insulation support (without block) shall be fixed at 30 cm space. |
| 166 | S&F aluminium earth strip as roof/down/earth contunity conductors of size 25x3mm with saddles, Parcelain, insulators, stainless steel screws, washer etc at any position / locationofsheds/ buildings of height up to 30 meter complete all as specified and directed by the Engineer-in-charge Note -i)The quoted rate is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter.ii) The rate is deemed to be inclusive of Procealin insulator, screws, Plugs etc. |
| 167 | Supply and fixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including allfittings for fixing complete as required and directed by Engineer-in-Charge. |
| 168 | M&L for painting on wall with synthetic enameledpaint of black colour of 200 x 150 mm size and writing work for earth test result with date & year all as specified and directed at site by Engineer-in-Charge. |
| 169 | Note : A SUM OF RS 54,565.00 TOWARDS SCHEDULE OF CREDIT SHALL BE DEDUCTED TO ARRIVE THE CONTRACT SUM |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy