}

Tender For Arrangement Of Fire Fighting Works At District Combined Hospital Kannauj (U.P.) - Providing, Laying, Testing & Commissioning Of C- Class Heavy Duty Ms Pipe On Surface Confirming To Is 1239 (Part-1) For Pipes Upto 150Mm Dia And Is: 3589-1991 For, kannauj-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Tender For Arrangement Of Fire Fighting Works At District Combined Hospital Kannauj (U.P.) - Providing, Laying, Testing & Commissioning Of C- Class Heavy Duty Ms Pipe On Surface Confirming To Is 1239 (Part-1) For Pipes Upto 150Mm Dia And Is: 3589-1991 For. Submission Date for this Tender is 03-10-2025. Fire Fighting Service Tenders in kannauj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51319380
Corrigendum : Tender For Arrangement Of Fire Fighting Works At District Combined Hospital Kannauj (U.P.) - Providing, Laying, Testing & Commissioning Of C- Class Heavy Duty Ms Pipe On Surface Confirming To Is 1239 (Part-1) For Pipes Upto 150Mm Dia And Is: 3589-1991 For
Tender
Indian
Uttar Pradesh
Kannauj
03-10-2025

Tender Details

Arrangement Of Fire Fighting Works At District Combined Hospital Kannauj (U.P.) - Providing, Laying, Testing & Commissioning of C- class heavy duty MS pipe on surface Confirming to IS 1239 (part-1) for pipes upto 150mm dia and IS: 3589-1991 for pipes above 150mm including cutting & welding with fitting like elbows , tees ,hanger ,flenges, taper , reducers, nuts, neoprene gasket & washer including cutting, welding etc. fixing the pipe on the Wall / Ceiling with suitable clamp and painted with red oxide and PO red enamel paint complete in all resspects.(a) 200 mm Dia 3 (b) 150 mm Dia 4 (c) 100 mm Dia 5 (d) 80 mm Dia 6 (e) 25 mm Dia 7 Providing, Laying, Testing & Commissioning of C- class heavy duty MS pipe on surface Confirming to IS 1239 (part-1) for pipes upto 150mm dia and IS: 3589-1991 for pipes above 150mm including cutting & welding with fitting like elbows , tees ,hanger ,flenges, taper , reducers, nuts, neoprene gasket & washer including cutting, welding etc. fixing the pipe on the Wall / Ceiling with suitable clamp and painted with red oxide and PO red enamel paint complete in all resspects. (FOR SPRINKLER)(a) 100 mm Dia 8 (b) 80 mm Dia 9 (c) 65 mm Dia 10 (d) 50 mm Dia 11 (e) 32 mm Dia 12 (f) 25 mm Dia 13 Providing, Fixing,Testing & commissioning of 15 mm Dia quartzoid bulb type Sprinklers of rating 68 degree centigrade with required accessories.Pendant sprinkler / sprinkler 14 Supplying, fixing, testing & commission of butterfly valve ofPN-16 slim seal standerd lever operated type as per design standerd IS:1395 or BS:5155 with required flanges, nut bolts etc. complete in all respects.(a) 200 mm dia 15 (b) 150 mm dia 16 (c) 100 mm dia 17 (d) 80 mm dia 18 Providing, installation, testing and commission of non-return valve offollowing sizes PN-10 as per design standerd IS: 5312 or BS:1868 with companion flanges, bolts, nuts, washers etc. complete in all respects.(a) 150 mm dia 19 (b) 100 mm dia 20 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 21 SupplyingInstallationtesting& Commissioningof 25 mm Air Release valve gunmentalhavingrubberballandwith25 mm BSP threaded male inletincluding necessary accessories and connections complete in all respect. 22 SupplyingInstallationtesting& Commissioningof 25 mm Ball valve PN-1 gunmental as per IS:778 including necessary accessories and connections. 23 SupplyingInstallationtesting& Commissioningof Foot valve including necessary accessories and connections.(a) 150 mm dia 24 (b) 100 mm dia 25 Providing & fixingofWeatherproofstandard fire hosecabinet boxmadeout of 18 gauge MSsheetincludingtwocoatsofpostoffice red paint over one coat of primer with 4 mm, thickglassdooronfrontpaintedFIREin red luminious paint, The size of thebox should be 750 mm X 600 mm X 250 mm size capable of accommodation a pair of hose with couplingand nozzel. The box should be floor mounted type with railway coach lock arrangementand leverfor openingthe door after breaking the glass complete. 26 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel 27 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304) 28 (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 450 Ipm at 35 m Head 29 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 30 Providing & fixing of pressure gauge in ranging from 0 to 14 kg per sqmm ISI marked from approved manufacturers complete in all respects. 31 Supplying fixing ofCast iron body 63 mm dia male instantaneousintelcouplingwith housing cabinet (500X400X400for 2 way and 600X400 for 4 way) cap and chain for fire brigadecorrection conformingto IS:904and makingconnectionwith fire fightingpipe or undergroundwater tank completing the work in all respect as per the directions of the Engineer-in-charge.Four Way connection 32 Providing/FixingofCubicaltypefloor mountedFire pump Controlpanel fabricated from16GM.S.sheetdulypowdercoated finish of aproved shade and comprising of:a) One 63 amp. TP+NL M.C.C.B. with rotary handle of beacking capacity 35 KA.b) One Volt meter (0-500V) with selector switch.c) One set including lamps 33 SupplyingLaying testing & Commissioningof 2 corex 1.5 sq.mmsingle standard copper conductor, PVCinsulatedarmoured cable. 34 Supply and laying of alluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on side and on top on surface the cable run shall be fied on M.S. clamps etc. of suitable size or as directed by the Engineer-in-charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(a) 150 sqmm 3-1/2 core 35 (b) 50 sqmm 3-1/2 core 36 (c) 25 sqmm 3-1/2 core 37 Supply, Installation, Testing & commissioning of Single/Double sided Signage with 20 mtr. viewing distance with built in LED, High efficiency L80 LED with 50,000 hour life, Usage: Exit Signage cum Emergency light with Function Use either as an emergency luminaire or exit sign, with standalone Testing system, Housing of Polycarbonate, Glow wire test : 850°C, RAL9003, Type of mounting: Wall or ceiling, Operation Mode Non -Maintained or Maintained mode selectable, Connection voltage 230V +/- 5% [220V-240V], compliant with EN standards, with IEC CB test certificate LED, Built in Battery: Ni-Cd, Duration 3 hours, Viewing distance 2+A300m, Dimensions in mm: 270 x 119 x 49. 38 P&F of Fire man axe made of carbon steel handle insulated with rubber tested to 20,000 Volts. Manufactured as per Indian standard IS:926. 39 Providing and fixing pressure switch in M.S. pipe line including connection as required 40 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license. 41 Supply and fixing of Single way landing / Hydrant / Yard Hydrant valve 63 mm dia. Gun metal instantanous with female coupling with chain etc. complete.Single Headed Gunmetal 42 Surfacedressingofroadwithpainting betweenusing 2.25 kg. of bitumenper sq.mt with 1.65 cum of stone chipping ,13.2 mm nominal size/100 sq.mt of road surface including corolidation. 43 Testing & Commissioning of Electric Driven Main Fire Pump Suitable for auto operation & consisting of following: complete in all respect as required.(a) Horizontal split Casing type, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft Mechanical seal at specified flow of 1620 lpm at 70 Meter head confirming to IS 1520.(b) Suitable HP squirrel cage induction motor,TEFC synchronous speed 1500 RPM 60 HP (with permissible slip) suitable for operation on 415 volts, 3 phase 50Hz.AC with IP 55 protectiion for enclosure, horizontal foot mounted type with class- F insulation, conferming to IS-325(c) Common base frame fabricated out of M.S channel of suitable size flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc.(d) Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. 44 Testing & Commissioning of Diesel Engine Driven main fire pump suitable for auto operation & consisting of following: complete in all respect as required.(a) Horizontal split Casing type,centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, Mechanical seal at specified flow of 1620 lpm at 70 meter head confirming to IS 1520.(b) Suitable HP 1500 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories/system, fuel oil filter ,lubricant oil pump with filter, 1 set Starting batteries of 180AH capicity each with suitable angle iron stand,engine starting panel havng all the controls meters, gauges,techo meter,hour meter, starting switch with keys for manual starting, auto starting mechanism, 12/24 volt electric starting equipment, Deisel tank for 8 hrs continuous running for Diesel Engine having minimum capicity of 200 Ltrs. (Tank made out of 3mm thick M.S.Sheet with filling cap, drain cock, diesel indicator duly mounted on M.S.angle) exhaust pipe of minimum 10 mtr. length, duly insulated with 50 mm thick glass wool with 1.0 mm.thick alluminium sheet cladding, exuast reidential silencer,stop solenold for auto stop in the event of fault with audio indications, painting etc. as required.(c) M.S fabricated Common base frame, flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc.Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. 45 Testing & commission of Electric Driven Pressurisation Pump (Jockey Pump) suitable for auto operation consisting of following complete in all respect as required.Horizontal type, centrifugal & suction type, pump of cast iron body & bronze impeller with stainless steel shaft Mechanical seal, gland packing & flow of 180 lpm at 70 Mtr. Head confirming to IS:-1520.Common base frame fabricated out of M.S channel of suitable able size flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc.Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. 46 Testing and Commissioning of cubical type floor/wall mounted, dust & vermin proof, fabricated with 16 swag. C.R.C.A. sheet steel, TPN bus bar 415V AC, 50HZ, compartmentalized, powder coated control panel for automatic /manual operation of Main Motor, Jockey, Diesel Engine with suitable switchgear, relays control and other components such as pressure switch, level indicator for UG Tank flow switch, starter for electrical motor, single phasing presenters and power control cable work, battery for operation of control including battery charger interconnection within the panel and along with components and motors complete in all respects. 47 SITC Automatic priming arrangement for all fire pumps including necessary pipe, fitting, water level controller, 1 HP pump, auto starter gate valve NRVs etc complete. 48 Making Holes with core cutting as per specified dia & depth including stacking of dismantled materials as directed by Engineer-in-charge with in a distance of 60 meters.(a) 25 mm dia (9) 49 (b) 32 mm dia (9) 50 (c) 50 mm dia (9) 51 (d) 80 mm dia (9) 52 (e) 100 mm dia (9) 53 (f) 150 mm dia (9) 54 Grounting of holes with plaster & painting with matching color as per specified dia & depth including cost of materials complete in all respects as directed by Engineer-in-charge.(a) 25 mm dia 55 (b) 32 mm dia 56 (c) 50 mm dia 57 (d) 80 mm dia 58 (e) 100 mm dia 59 (f) 150 mm dia 60 Drilling & Grounting of holes with DE-Walt Pure 150- Pro Chemical as per specified dia & depth including cost of materials complete in all respects as directed by Engineer-in-charge.16 mm dia (9) 61 Addressable Fire Alarm system- 62 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM),power supply unit (230 + 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel 63 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal (smoke cum heat) detector complete with mounting base complete as required. 64 Supplying, installation, testing & commissioning of intelligent addressable thermal (heat) detector with rate of rise cum fixed tempreature thermistor complete with base as required. 65 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 66 SupplyingInstallationtesting& Commissioningof Intelligent Addressable Manual Call points- double action Break Glass cum pull station suitable for wall/column mounting. 67 SupplyingInstallationtesting& Commissioningof Intelligent Addressable Hooter cum multi carriar strobe.Unit as per specificationsand customizationof intensity selectionas15,30 , 75 or110cdof strobe unit is possibleby panel.Soundersum strobe willbedrivenbysupervised24 V DCinput and will give 80 db output at 3 m strobe unite willbesynchronized1Hzstrobeflashrate for better evacuation in complete facility. 68 SupplyingInstallationtesting& CommissioningIntelligent Addressablesingle AddressableControl Relay Module-Form C contacttype. 69 SupplyingLaying testing & Commissioningof 2 corex 1.5 sq.mmsingle standard copper conductor, PVCinsulatedarmored cable. 70 Supply & fixing of CO2 type fire extinguisher,4.5 kg. capacity (ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 71 Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 72 Supply & fixing of fire Bucket 4+ with stand 73 Supply & fixing of Electrode Earthing Complete. 74 Manual Fire Alarm System 75 Supplying, installation, testing & commissioning sector panel suitable for 4 zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per 1S:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 76 Testing & commissioning sector panel suitable for 4 zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per 1S:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 77 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 78 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 79 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 80 Supplying, installation, testing & commissioning response indicator surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 81 Providing & erecting direction & place identification& other fire related informations for emergency retro- reflectorised sign as per IRC-67 made of high intensity grade sheeting. The retro reflective sheeting type-IV shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67:2012 & proof of the same in form of government report shall be uploaded while quoting tender vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area exceeding 0.9 sqm. Supproted on a mild steel single angle iron post 75x75x6 mm, 2 nos firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing complete. 82 RESOURCES TRAINING FOR STAFF & TRAINING MODULES FOR RESCUE OPERATION 83 GST Extra as applicable

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 23-09-2025 Date Date 03-10-2025

Key Value

Document Fees
INR 17700 /-
EMD
INR 253000.0 /-
Tender Value
INR 1.26 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail