Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-12-2025 | BDD EXTENSION6 | Date | 11-12-2025 |
| 2 | 03-12-2025 | BDD EXTENSION5 | Date | 08-12-2025 |
| 3 | 20-11-2025 | COMMERCIAL AMENDMENT NO.2 | Technical Bid | 03-12-2025 |
| 4 | 19-11-2025 | BID DUE DATE | Date | 03-12-2025 |
| 5 | 07-11-2025 | BDD EXTENSION no. THREE | Date | 19-11-2025 |
| 6 | 23-10-2025 | BDD Extension | Date | 12-11-2025 |
| 7 | 07-10-2025 | PRE-BID QUERY SUB. TIME DATE | Date | 28-10-2025 |
| 8 | 03-10-2025 | BDD EXTENSION | Date | 28-10-2025 |
| 9 | 29-09-2025 | PRE-BID QUERY SUBMISSION TIME DATE | Date | 08-10-2025 |
| Sl. No. | Item Description |
| 1 | PIPING-OFFSITES |
| 2 | PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. |
| 3 | CARBON STEEL PIPING (NON IBR); THK. <= 10MM |
| 4 | FABRICATION (BUTT WELD- MANUAL) |
| 5 | NB UPTO 1.5 INCH |
| 6 | NB 2 INCH - 6 INCH |
| 7 | NB 8 INCH - 14 INCH |
| 8 | NB 16 INCH - 24 INCH |
| 9 | NB 26 INCH - 36 INCH |
| 10 | FABRICATION (FILLET WELD) |
| 11 | NB UPTO 1.5 INCH |
| 12 | ERECTION (OTHER THAN SPOOL) |
| 13 | NB UPTO 1.5 INCH |
| 14 | NB 2 INCH - 6 INCH |
| 15 | NB 8 INCH - 14 INCH |
| 16 | NB 16 INCH - 24 INCH |
| 17 | NB 26 INCH - 36 INCH |
| 18 | CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM |
| 19 | FABRICATION (BUTT WELD- MANUAL) |
| 20 | NB 8 INCH - 14 INCH |
| 21 | NB 16 INCH - 24 INCH |
| 22 | NB 38 INCH - 48 INCH |
| 23 | ERECTION (OTHER THAN SPOOL) |
| 24 | NB 8 INCH - 14 INCH |
| 25 | NB 16 INCH - 24 INCH |
| 26 | NB 38 INCH - 48 INCH |
| 27 | STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM |
| 28 | FABRICATION (BUTT WELD- MANUAL) |
| 29 | NB UPTO 1.5 INCH |
| 30 | NB 2 INCH - 6 INCH |
| 31 | FABRICATION (FILLET WELD) |
| 32 | NB UPTO 1.5 INCH |
| 33 | ERECTION (OTHER THAN SPOOL) |
| 34 | NB UPTO 1.5 INCH |
| 35 | NB 2 INCH - 6 INCH |
| 36 | VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. |
| 37 | FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) |
| 38 | NB2.000 INCHES |
| 39 | NB3.000 INCHES |
| 40 | NB4.000 INCHES |
| 41 | NB6.000 INCHES |
| 42 | NB8.000 INCHES |
| 43 | NB 10.000 INCHES |
| 44 | NB 12.000 INCHES |
| 45 | NB 20.000 INCHES |
| 46 | NB 24.000 INCHES |
| 47 | NB 42.000 INCHES |
| 48 | SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owner\"s storage points to contractor\"s stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. |
| 49 | SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 |
| 50 | BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. |
| 51 | 150# JOINTS |
| 52 | NB 12.000 INCHES |
| 53 | NB 16.000 INCHES |
| 54 | NB 18.000 INCHES |
| 55 | NB 20.000 INCHES |
| 56 | NB 24.000 INCHES |
| 57 | NB 42.000 INCHES |
| 58 | 300# JOINTS |
| 59 | NB 12.000 INCHES |
| 60 | NB 24.000 INCHES |
| 61 | REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe |
| 62 | C.S REINFORCING PADS |
| 63 | NB2.000 INCHES |
| 64 | NB3.000 INCHES |
| 65 | NB6.000INCHES |
| 66 | NB8.000 INCHES |
| 67 | NB 10.000INCHES |
| 68 | NB 12.000 INCHES |
| 69 | NB 18.000INCHES |
| 70 | NB 24.000 INCHES |
| 71 | NB 28.000 INCHES |
| 72 | RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. |
| 73 | FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) |
| 74 | NB0.750 INCHES |
| 75 | NB1.000 INCHES |
| 76 | NB1.500 INCHES |
| 77 | NB2.000 INCHES |
| 78 | NB3.000 INCHES |
| 79 | NB4.000 INCHES |
| 80 | NB6.000 INCHES |
| 81 | FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) |
| 82 | NB2.000 INCHES |
| 83 | FOR JOINTS ABOVE THK. 8MM |
| 84 | NB8.000 INCHES |
| 85 | NB 12.000 INCHES |
| 86 | NB 18.000 INCHES |
| 87 | NB 24.000 INCHES |
| 88 | NB 42.000 INCHES |
| 89 | DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. |
| 90 | DYE PENETRANT TEST |
| 91 | MAGNETIC PARTICLE TEST |
| 92 | PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. |
| 93 | DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) |
| 94 | DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) |
| 95 | PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. |
| 96 | C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) |
| 97 | S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) |
| 98 | DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) |
| 99 | DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) |
| 100 | WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6\" NB : 240 kg/cm3 Density for lines above 6\" NB : 320 kg/cm3 |
| 101 | WOODEN BLOCKS |
| 102 | HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS |
| 103 | HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS |
| 104 | CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. |
| 105 | PASSIVATION OF COOLING WATER LINES |
| 106 | NB0.500 INCHES |
| 107 | NB0.750 INCHES |
| 108 | NB1.000 INCHES |
| 109 | NB1.500 INCHES |
| 110 | NB2.000 INCHES |
| 111 | NB3.000 INCHES |
| 112 | NB4.000 INCHES |
| 113 | NB6.000 INCHES |
| 114 | NB8.000 INCHES |
| 115 | NB 10.000 INCHES |
| 116 | NB 12.000 INCHES |
| 117 | NB 14.000 INCHES |
| 118 | NB 16.000 INCHES |
| 119 | NB 18.000 INCHES |
| 120 | NB 20.000 INCHES |
| 121 | NB 24.000 INCHES |
| 122 | NB 42.000 INCHES |
| 123 | FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owner\"s storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge |
| 124 | BLINDS |
| 125 | NB0.750 INCHES |
| 126 | NB1.000 INCHES |
| 127 | NB1.500 INCHES |
| 128 | NB2.000 INCHES |
| 129 | NB3.000 INCHES |
| 130 | NB4.000 INCHES |
| 131 | NB6.000 INCHES |
| 132 | NB8.000 INCHES |
| 133 | NB 12.000 INCHES |
| 134 | NB 24.000 INCHES |
| 135 | NB 42.000 INCHES |
| 136 | SPECTACLE BLINDS |
| 137 | NB2.000 INCHES |
| 138 | NB3.000 INCHES |
| 139 | SPACERS & BLINDS |
| 140 | NB 24.000 INCHES |
| 141 | NB 42.000 INCHES |
| 142 | SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1\" and 3 nuts for diamemter >= 1\"of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. |
| 143 | AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) |
| 144 | MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. |
| 145 | FLAME CUTTING C.S PIPINGIBR/NON IBR |
| 146 | HACKSAW CUTTING C.S PIPINGIBR/NON IBR |
| 147 | BEVELLINGC.S PIPINGIBR/NON IBR |
| 148 | FITUP & WELDINGC.S PIPINGIBR/NON IBR |
| 149 | FLAME CUTTINGS.S PIPINGIBR/NON IBR |
| 150 | HACKSAW CUTTINGS.S PIPINGIBR/NON IBR |
| 151 | BEVELLINGS.S PIPINGIBR/NON IBR |
| 152 | FITUP & WELDINGS.S PIPINGIBR/NON IBR |
| 153 | REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. |
| 154 | C.S/A.S PIPING |
| 155 | S.S PIPING |
| 156 | REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owner\"s storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. |
| 157 | VALVES OTHER THAN CONTROL VALVES |
| 158 | NB0.500 INCHES |
| 159 | NB0.750 INCHES |
| 160 | NB1.000 INCHES |
| 161 | NB1.500 INCHES |
| 162 | NB2.000 INCHES |
| 163 | NB3.000 INCHES |
| 164 | NB4.000 INCHES |
| 165 | NB6.000 INCHES |
| 166 | NB8.000 INCHES |
| 167 | NB 10.000 INCHES |
| 168 | NB 12.000 INCHES |
| 169 | NB 24.000 INCHES |
| 170 | NB 42.000 INCHES |
| 171 | LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. |
| 172 | TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI |
| 173 | GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI |
| 174 | PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractor\"s supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. |
| 175 | SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) |
| 176 | SEMI SKILLED (WITH HAND TOOLS) |
| 177 | HELPER/ UNSKILLED |
| 178 | PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. |
| 179 | SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 |
| 180 | SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/owner\"sstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client |
| 181 | PIPES |
| 182 | PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 |
| 183 | PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 |
| 184 | PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS |
| 185 | PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS |
| 186 | PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S |
| 187 | PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S |
| 188 | PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S |
| 189 | FLANGES |
| 190 | FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS |
| 191 | FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS |
| 192 | FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 |
| 193 | FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS |
| 194 | FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS |
| 195 | FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S |
| 196 | FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH |
| 197 | FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH |
| 198 | FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH |
| 199 | FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH |
| 200 | FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH |
| 201 | FITTINGS |
| 202 | ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH |
| 203 | ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH |
| 204 | ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH |
| 205 | ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH |
| 206 | T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH |
| 207 | T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH |
| 208 | T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH |
| 209 | SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 |
| 210 | CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH |
| 211 | CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH |
| 212 | CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH |
| 213 | CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH |
| 214 | CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH |
| 215 | CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH |
| 216 | CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH |
| 217 | VALVES |
| 218 | VLV.GATE, SHEET 51001, 0.5 INCH |
| 219 | VLV.GATE, SHEET 51001, 0.75 INCH |
| 220 | VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN |
| 221 | VLV.GATE, SHEET 51001, 1.0 INCH |
| 222 | VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN |
| 223 | VLV.GATE, SHEET 51001, 1.5 INCH |
| 224 | VLV.GATE, SHEET 51007, 0.75 INCH |
| 225 | VLV.GATE, SHEET 51045, 0.5 INCH |
| 226 | VLV.GATE, SHEET 51045, 0.75 INCH |
| 227 | VLV.GLOBE, SHEET 52001, 1.0 INCH |
| 228 | VLV.GLOBE, SHEET 52007, 1.0 INCH |
| 229 | VLV.CHECK, SHEET 53001, 1.0 INCH |
| 230 | VLV.CHECK, SHEET 53007, 1.0 INCH |
| 231 | VLV.CHECK, SHEET 53050, 0.75 INCH |
| 232 | GASKETS |
| 233 | GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH |
| 234 | GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH |
| 235 | GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH |
| 236 | GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH |
| 237 | GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH |
| 238 | FASTENERS |
| 239 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH |
| 240 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH |
| 241 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH |
| 242 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH |
| 243 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH |
| 244 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH |
| 245 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH |
| 246 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH |
| 247 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH |
| 248 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH |
| 249 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH |
| 250 | BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH |
| 251 | CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using \"SELENIUM\"& \"IRIDIUM\" source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractor\"s fault and for additional radiographynecessitated due to poor performance of contractor\"swelders shall be done at contractor\"s cost).Note: Unit for radiography quantity is \"Nos ofcircumferencial weld joints\", and rates are also inclusive of scaffoldings wherverrequired. |
| 252 | FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) |
| 253 | NB0.750 INCHES |
| 254 | NB1.000 INCHES |
| 255 | NB1.500 INCHES |
| 256 | NB2.000 INCHES |
| 257 | NB3.000 INCHES |
| 258 | NB4.000 INCHES |
| 259 | NB6.000 INCHES |
| 260 | FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) |
| 261 | NB2.000 INCHES |
| 262 | FOR JOINTS ABOVE THK. 8MM |
| 263 | NB8.000 INCHES |
| 264 | NB 12.000 INCHES |
| 265 | NB 18.000 INCHES |
| 266 | NB 24.000 INCHES |
| 267 | Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. |
| 268 | STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 |
| 269 | External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) |
| 270 | NB0.500 INCHES |
| 271 | NB0.750 INCHES |
| 272 | NB1.000 INCHES |
| 273 | NB1.500 INCHES |
| 274 | NB2.000 INCHES |
| 275 | PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. |
| 276 | SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 |
| 277 | DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. |
| 278 | PIPES |
| 279 | NB: .5Inches |
| 280 | NB: .75 Inches |
| 281 | NB: 1 Inches |
| 282 | NB: 1.5 Inches |
| 283 | NB: 2 Inches |
| 284 | NB: 3 Inches |
| 285 | NB: 4 Inches |
| 286 | NB: 6 Inches |
| 287 | NB: 8 Inches |
| 288 | NB: 12Inches |
| 289 | VALVES |
| 290 | NB: .5Inches |
| 291 | NB: .75 Inches |
| 292 | NB: 1 Inches |
| 293 | NB: 1.5 Inches |
| 294 | NB: 2 Inches |
| 295 | NB: 3 Inches |
| 296 | NB: 4 Inches |
| 297 | NB: 6 Inches |
| 298 | NB: 8 Inches |
| 299 | NB: 12Inches |
| 300 | SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 |
| 301 | DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 |
| 302 | PIPES |
| 303 | NB: .5Inches |
| 304 | NB: .75 Inches |
| 305 | NB: 1 Inches |
| 306 | NB: 1.5 Inches |
| 307 | NB: 2 Inches |
| 308 | NB: 3 Inches |
| 309 | NB: 4 Inches |
| 310 | NB: 6 Inches |
| 311 | NB: 8 Inches |
| 312 | NB: 12Inches |
| 313 | NB: 18Inches |
| 314 | NB: 24Inches |
| 315 | NB: 28Inches |
| 316 | NB: 36Inches |
| 317 | NB: 42Inches |
| 318 | VALVES |
| 319 | NB: .5Inches |
| 320 | NB: .75 Inches |
| 321 | NB: 1 Inches |
| 322 | NB: 1.5 Inches |
| 323 | NB: 2 Inches |
| 324 | NB: 3 Inches |
| 325 | NB: 4 Inches |
| 326 | NB: 6 Inches |
| 327 | NB: 8 Inches |
| 328 | NB: 12Inches |
| 329 | NB: 18Inches |
| 330 | NB: 24Inches |
| 331 | NB: 42Inches |
| 332 | SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 |
| 333 | DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. |
| 334 | PIPES |
| 335 | NB0.50 INCHES |
| 336 | NB0.750 INCHES |
| 337 | NB1.000 INCHES |
| 338 | NB1.500 INCHES |
| 339 | NB2.000 INCHES |
| 340 | NB3.000 INCHES |
| 341 | NB4.000 INCHES |
| 342 | NB6.000 INCHES |
| 343 | NB12.000 INCHES |
| 344 | VALVES |
| 345 | NB0.50 INCHES |
| 346 | NB0.750 INCHES |
| 347 | NB1.000 INCHES |
| 348 | NB1.500 INCHES |
| 349 | NB2.000 INCHES |
| 350 | NB3.000 INCHES |
| 351 | NB4.000 INCHES |
| 352 | NB6.000 INCHES |
| 353 | NB12.000 INCHES |
| 354 | *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer \" Job specification for Insulation of Piping and Equipment\", B861-000-06-43-IL-S001*************************************************************** |
| 355 | COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturer\"s shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) |
| 356 | INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) |
| 357 | INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) |
| 358 | PIPES |
| 359 | NB 00.75 INCHES; THICKNESS25 MM |
| 360 | NB 01.00INCHES; THICKNESS25 MM |
| 361 | NB 01.50 INCHES; THICKNESS50 MM |
| 362 | NB 02.00 INCHES; THICKNESS50 MM |
| 363 | NB 06.00INCHES; THICKNESS50 MM |
| 364 | NB 08.00INCHES; THICKNESS50 MM |
| 365 | NB 012.000INCHES; THICKNESS60 MM |
| 366 | NB 018.000INCHES; THICKNESS60 MM |
| 367 | NB 24.00 INCHES; THICKNESS60 MM |
| 368 | NB 28.00 INCHES; THICKNESS60 MM |
| 369 | NB 42.00 INCHES; THICKNESS60 MM |
| 370 | FLANGE ASSEMBLIES |
| 371 | NB 00.75INCHES; THICKNESS25 MM |
| 372 | NB 01.00INCHES; THICKNESS25 MM |
| 373 | NB 01.50 INCHES; THICKNESS50 MM |
| 374 | NB 02.00INCHES; THICKNESS50 MM |
| 375 | NB 06.00INCHES; THICKNESS50 MM |
| 376 | NB 08.00INCHES; THICKNESS50 MM |
| 377 | NB 012.000INCHES; THICKNESS60 MM |
| 378 | NB 018.000INCHES; THICKNESS60 MM |
| 379 | NB 24.00 INCHES; THICKNESS60 MM |
| 380 | NB 42.00 INCHES; THICKNESS60 MM |
| 381 | BLIND FLANGE ASSEMBLIES |
| 382 | NB 00.75 INCHES; THICKNESS25 MM |
| 383 | NB 08.00 INCHES; THICKNESS50 MM |
| 384 | VALVE ASSEMBLIES |
| 385 | NB 00.75 INCHES; THICKNESS25 MM |
| 386 | NB 01.00INCHES; THICKNESS25 MM |
| 387 | NB 01.50INCHES; THICKNESS50 MM |
| 388 | NB 02.00 INCHES; THICKNESS50 MM |
| 389 | NB 06.00INCHES; THICKNESS50 MM |
| 390 | NB 08.00 INCHES; THICKNESS50 MM |
| 391 | NB 012.000INCHES; THICKNESS60 MM |
| 392 | NB 018.000INCHES; THICKNESS60 MM |
| 393 | NB 24.00 INCHES; THICKNESS60 MM |
| 394 | NB 42.00 INCHES; THICKNESS60 MM |
| 395 | INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) |
| 396 | PIPES |
| 397 | NB 00.50 INCHES; THICKNESS25 MM |
| 398 | NB 00.75 INCHES; THICKNESS25 MM |
| 399 | NB 01.00 INCHES; THICKNESS25 MM |
| 400 | NB 01.50 INCHES; THICKNESS25 MM |
| 401 | NB 02.00 INCHES; THICKNESS25 MM |
| 402 | NB 03.00 INCHES; THICKNESS25 MM |
| 403 | NB 04.00 INCHES; THICKNESS40 MM |
| 404 | NB 06.00 INCHES; THICKNESS25 MM |
| 405 | NB 06.00 INCHES; THICKNESS40 MM |
| 406 | NB 08.00 INCHES; THICKNESS25 MM |
| 407 | NB 08.00 INCHES; THICKNESS40 MM |
| 408 | NB 12.00 INCHES; THICKNESS40 MM |
| 409 | NB 18.00 INCHES; THICKNESS40 MM |
| 410 | NB 24.00 INCHES; THICKNESS40 MM |
| 411 | NB 24.00 INCHES; THICKNESS50 MM |
| 412 | NB 28.00 INCHES; THICKNESS50 MM |
| 413 | NB 42.00 INCHES; THICKNESS50 MM |
| 414 | FLANGE ASSEMBLIES |
| 415 | NB 00.50INCHES; THICKNESS25 MM |
| 416 | NB 00.75INCHES; THICKNESS25 MM |
| 417 | NB 01.00INCHES; THICKNESS25 MM |
| 418 | NB 01.50 INCHES; THICKNESS25 MM |
| 419 | NB 02.00 INCHES; THICKNESS25 MM |
| 420 | NB 03.00INCHES; THICKNESS25 MM |
| 421 | NB 04.00INCHES; THICKNESS40 MM |
| 422 | NB 06.00 INCHES; THICKNESS25 MM |
| 423 | NB 06.00 INCHES; THICKNESS40 MM |
| 424 | NB 08.00INCHES; THICKNESS25 MM |
| 425 | NB 08.00INCHES; THICKNESS40 MM |
| 426 | NB 12.00 INCHES; THICKNESS40 MM |
| 427 | NB 018.000INCHES; THICKNESS40 MM |
| 428 | NB 24.00 INCHES; THICKNESS40 MM |
| 429 | NB 24.00 INCHES; THICKNESS50 MM |
| 430 | NB 42.00 INCHES; THICKNESS50 MM |
| 431 | BLIND FLANGE ASSEMBLIES |
| 432 | NB 00.75 INCHES; THICKNESS25 MM |
| 433 | NB 01.00 INCHES; THICKNESS25 MM |
| 434 | NB 01.50 INCHES; THICKNESS25 MM |
| 435 | NB 02.00 INCHES; THICKNESS25 MM |
| 436 | NB 08.00 INCHES; THICKNESS40 MM |
| 437 | NB 24.00 INCHES; THICKNESS50 MM |
| 438 | VALVE ASSEMBLIES |
| 439 | NB 00.50 INCHES; THICKNESS25 MM |
| 440 | NB 00.75 INCHES; THICKNESS25 MM |
| 441 | NB 01.00 INCHES; THICKNESS25 MM |
| 442 | NB 01.50 INCHES; THICKNESS25 MM |
| 443 | NB 02.00 INCHES; THICKNESS25 MM |
| 444 | NB 03.00 INCHES; THICKNESS25 MM |
| 445 | NB 04.00 INCHES; THICKNESS40 MM |
| 446 | NB 06.00INCHES; THICKNESS25 MM |
| 447 | NB 06.00INCHES; THICKNESS40 MM |
| 448 | NB 08.00 INCHES; THICKNESS25 MM |
| 449 | NB 08.00 INCHES; THICKNESS40 MM |
| 450 | NB 12.00 INCHES; THICKNESS40 MM |
| 451 | NB 018.000INCHES; THICKNESS40 MM |
| 452 | NB 24.00 INCHES; THICKNESS40 MM |
| 453 | NB 24.00 INCHES; THICKNESS50 MM |
| 454 | NB 42.00 INCHES; THICKNESS50 MM |
| 455 | ELECTRICAL WORKS |
| 456 | Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer\"s works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. |
| 457 | 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) |
| 458 | Microprocessor based Repeater panel with battery and charger (refer block diagram) |
| 459 | Multi - sensor type addressable detectors with junction boxes for safe area |
| 460 | Intrinsically safeHeat Detector-addressable type |
| 461 | Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. |
| 462 | Zener barrier |
| 463 | Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. |
| 464 | Indoor addressable Break Glass Unit (BGU) in safe area. |
| 465 | Addressable type electronic hooter with minimum 6W output |
| 466 | Wall mounting type one faced exit signs suitable for indoor location |
| 467 | Ceiling mounting type double faced exit signs suitable for indoor location |
| 468 | Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units |
| 469 | Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. |
| 470 | Control modules with integral junction box installed within loop |
| 471 | Input Module with integral junction box installed within loop |
| 472 | Industrial type 5 km diametrical range siren with Siren control & starter panel |
| 473 | Response indicator for rooms and concealed area for Addressable Fire alarm system |
| 474 | Hooter acknowledge Box |
| 475 | Providing training for TWO Nos. OWNER\"s Engineers for a period of 4 days at manufacturer works for Fire Alarm system |
| 476 | Providing training for FIVE Nos. OWNER\"s Engineers at site for the complete fire alarm system |
| 477 | Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 |
| 478 | Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK |
| 479 | Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK |
| 480 | Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 481 | Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer\"s works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. |
| 482 | Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of \"DD Electronic Equipment’s PVT Ltd\" make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is \"DD Electronic Equipment’s PVT Ltd\" with Model No: LDD8950/20 |
| 483 | 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipment\"s. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 |
| 484 | Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipment\"s. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T |
| 485 | Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. |
| 486 | Unit Rates for UPS ACDB feeders/components |
| 487 | Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer |
| 488 | Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer |
| 489 | Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer |
| 490 | Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer |
| 491 | Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer |
| 492 | Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer |
| 493 | supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar |
| 494 | Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) |
| 495 | Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) |
| 496 | Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) |
| 497 | Supply, mounting & wiring of 100A switch |
| 498 | Supply, mounting & wiring of 63A switch |
| 499 | Supply, mounting & wiring of 32A switch |
| 500 | Supply, mounting & wiring of 100A semiconducting fuse |
| 501 | Supply, mounting & wiring of 63A semiconducting fuse |
| 502 | Supply, mounting & wiring of 32A semiconducting fuse |
| 503 | Supply, mounting & wiring of 100A HRC fuse |
| 504 | Supply, mounting & wiring of 63A HRC fuse |
| 505 | Supply, mounting & wiring of 32A HRC fuse |
| 506 | Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer |
| 507 | Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer |
| 508 | Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer |
| 509 | Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer |
| 510 | Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer |
| 511 | Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer |
| 512 | Unit rates for 110V DCDB feeders/components |
| 513 | supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar |
| 514 | Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder |
| 515 | Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder |
| 516 | Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder |
| 517 | Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder |
| 518 | Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder |
| 519 | Supply, mounting & wiring of 100A, 110V DC Switch |
| 520 | Supply, mounting & wiring of 63A, 110V DC Switch |
| 521 | Supply, mounting & wiring of 32A, 110V DC Switch |
| 522 | Supply, mounting & wiring of 16A, 110V DC Switch |
| 523 | Supply, mounting & wiring of 100A, 110V DC fuse Link |
| 524 | Supply, mounting & wiring of 63A, 110V DC fuse Link |
| 525 | Supply, mounting & wiring of 32A, 110V DC fuse Link |
| 526 | Supply, mounting & wiring of 16A, 110V DC fuse Link |
| 527 | Supply, mounting & wiring of 100A, 110V DC contactor |
| 528 | Supply, mounting & wiring of 63A, 110V DC contactor |
| 529 | Supply, mounting & wiring of 32A, 110V DC contactor |
| 530 | Supply, mounting & wiring of 16A, 110V DC contactor |
| 531 | TRANSFORMERS |
| 532 | Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractor\"s own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 533 | 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A |
| 534 | 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A |
| 535 | 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A |
| 536 | Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). |
| 537 | Filtration of transformer oil with dissolved gas analysis test. |
| 538 | Filtration of transformer oil without dissolved gas analysis test. |
| 539 | Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. |
| 540 | No. of Drums. |
| 541 | Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 542 | 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A |
| 543 | 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A |
| 544 | Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 545 | 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A |
| 546 | 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A |
| 547 | Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. |
| 548 | 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A |
| 549 | 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A |
| 550 | 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A |
| 551 | SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS |
| 552 | Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 553 | Weight of the Unit upto 100 kg. |
| 554 | Weight of the Unit from 101 upto 500 kg. |
| 555 | Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. |
| 556 | Weight of the Unit upto 100 kg. |
| 557 | Weight of the Unit from 101 upto 500 kg. |
| 558 | Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 559 | Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second |
| 560 | Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second |
| 561 | Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 562 | Weight of the Unit upto 100 kg |
| 563 | Weight of the Unit from 101 upto 500 kg. |
| 564 | Weight of the Unit from 501 upto 1000 kg. |
| 565 | Weight of the Unit from 1001 upto 1500 kg. |
| 566 | Weight of the Unit from 1501 upto 3000 kg. |
| 567 | Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 568 | Weight of the Unit upto 100 kg |
| 569 | Weight of the Unit from 101 upto 500 kg. |
| 570 | Weight of the Unit from 501 upto 1000 kg. |
| 571 | Weight of the Unit from 1001 upto 1500 kg. |
| 572 | Weight of the Unit from 1501 upto 3000 kg. |
| 573 | Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer\"s works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. |
| 574 | 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 |
| 575 | 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. |
| 576 | 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification |
| 577 | Cell booster of adequate rating suitable for battery AH capacity. |
| 578 | Providing training to 2 nos. owner\"s engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system |
| 579 | Providing training to 5 nos. owner\"s engineers at site for 55KVA UPS system |
| 580 | Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 |
| 581 | MISCELLANEOUS CONTROL GEAR |
| 582 | Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 583 | Weight of the unit above 5 kg. but upto 20 kg. |
| 584 | Weight of the unit above 20 kg. but upto 100 kg. |
| 585 | Weight of the unit up to 5 kg. |
| 586 | Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 587 | With stop (latching type) push button. |
| 588 | With stop (non-latching type) push button. |
| 589 | With start and stop (latching type) push buttons. |
| 590 | With start, stop push buttons and ammeter. |
| 591 | With start,stop push buttons and one Three position selector switch. |
| 592 | With start,stop push buttons, one Three position selector switch and ammeter. |
| 593 | With stop push button (Break Glass Type). |
| 594 | With start and stop (non-latching type) push buttons. |
| 595 | Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 596 | With start, stop push buttons and one Three position selector switch and ammeter. |
| 597 | DC SYSTEM / BATTERY BANK |
| 598 | Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 599 | 160A (Min.) , dual redundant battery charger as per data sheet DS-430 |
| 600 | 110V, 1x500AH(Min.), Ni-Cd battery bank |
| 601 | 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification |
| 602 | 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. |
| 603 | Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 |
| 604 | Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 605 | Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah |
| 606 | Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 607 | Cell booster rated for 12 V50 A |
| 608 | PLUGS, SOCKETS AND JUNCTION BOXES |
| 609 | Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 610 | 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. |
| 611 | 240 V, 15 A, 3 pin sockets. |
| 612 | 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. |
| 613 | 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) |
| 614 | Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 615 | WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs |
| 616 | WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. |
| 617 | WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. |
| 618 | NEUTRAL GROUNDING RESISTOR |
| 619 | Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. |
| 620 | NGR rated for 3.81 kV400 A |
| 621 | Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 622 | NGR rated for 3.81 kV400 A |
| 623 | CAPACITOR BANKS |
| 624 | Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 625 | 11kV, 3 Phase,indoor type APFC panel -1500kVAR |
| 626 | Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 |
| 627 | Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 628 | HV capacitor banks rated for 1500 kVAR11 kV |
| 629 | Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 630 | HV capacitor banks rated for 1500 kVAR11 kV |
| 631 | CANOPIES |
| 632 | Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 633 | Lighting Panel/Power panel/distribution junctions boxes. |
| 634 | Manual call points/field call stations. |
| 635 | Push button stations. |
| 636 | Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 637 | Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 638 | Frame size upto 80. |
| 639 | Frame size more than 80 and upto 112. |
| 640 | Frame size more than 112 and upto 180. |
| 641 | Frame size more than 180 and upto 250. |
| 642 | Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 643 | Lighting Panel/Power panel/distribution junctions boxes. |
| 644 | Manual call points/field call stations. |
| 645 | Push button stations. |
| 646 | FLP receptacles. |
| 647 | ANCHOR FASTENERS |
| 648 | Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 649 | 3/16\" BSW. |
| 650 | 5/16\" BSW. |
| 651 | 1/4\" BSW. |
| 652 | 3/8\" BSW. |
| 653 | 5/8\" BSW. |
| 654 | 1/2\" BSW. |
| 655 | SAFETY EQUIPMENT |
| 656 | Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. |
| 657 | Shock hazard charts complete with frame and glass. |
| 658 | First Aid Boxes. |
| 659 | 4.5 kg capacity CO2 type fire extinguishers. |
| 660 | 6.8 kg capacity CO2 type fire extinguishers. |
| 661 | 9 kg capacity CO2 type fire extinguishers. |
| 662 | Sand buckets with stand (Each with at least 3 sand buckets). |
| 663 | Shock hazard charts - Laminated type |
| 664 | Gas Mask for use in substation during fire & smoke as per CEA guidelines |
| 665 | Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. |
| 666 | 3.3 kV grade. |
| 667 | 11 kV grade. |
| 668 | Supply of following items as per applicable Indian standards/CEA Guidelines. |
| 669 | Rubber hand gloves (11 kV grade). |
| 670 | Rubber hand gloves (33 kV grade). |
| 671 | Enamelled caution boards. |
| 672 | Discharge rod with earthing facility (upto 11 kV grade). |
| 673 | HV fuse puller handle. |
| 674 | Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge |
| 675 | For highest systen voltage of 12.1kV |
| 676 | SUPPLY OF SPARES / LAMPS |
| 677 | MV HRC Fuses |
| 678 | 16 A. |
| 679 | 32 A. |
| 680 | 63 A. |
| 681 | 100 A. |
| 682 | 160 A. |
| 683 | 250 A. |
| 684 | SUPPLY OF MV CABLES |
| 685 | Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. |
| 686 | 2 C x 10 sq. mm |
| 687 | 2C x 16 sq. mm |
| 688 | 2 C x 2.5 sq. mm |
| 689 | 3 C x 6 sq. mm |
| 690 | 2 C x 4 sq. mm |
| 691 | 3 C x 4 sq. mm |
| 692 | 3 C x 10 sq. mm |
| 693 | 3 C x 2.5 sq. mm |
| 694 | Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. |
| 695 | 3 C x 25 sq. mm |
| 696 | 3.5 C x 25 sq. mm |
| 697 | 3 C x 35 sq. mm |
| 698 | 2 C x 50 sq. mm |
| 699 | 3 C x 95 sq. mm |
| 700 | 3 C x 120 sq. mm |
| 701 | 3.5 C x 185 sq. mm |
| 702 | 3 C x 240 sq. mm |
| 703 | 3 C x 50 sq. mm |
| 704 | 3.5 C x 35 sq. mm |
| 705 | 3.5 C x 95 sq. mm |
| 706 | 3.5 C x 300 sq. mm |
| 707 | 3.5 C x 50 sq. mm |
| 708 | 3.5 C x 120 sq. mm |
| 709 | Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. |
| 710 | 1 Pair x 2.5 sq. mm |
| 711 | 2 Pair x 2.5 sq. mm |
| 712 | 4 Pair x 2.5 sq. mm |
| 713 | 6 Pair x 2.5 sq. mm |
| 714 | 12 Pair x 2.5 sq. mm |
| 715 | SUPPLY OF HV CABLES (MULTI CORE) |
| 716 | Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. |
| 717 | 3 C x 240sq. mm, Al |
| 718 | Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. |
| 719 | 3 C x 240 sq. mm, Al |
| 720 | 3 C x 300 sq. mm, Al |
| 721 | SUPPLY OF HV CABLES (SINGLE CORE) |
| 722 | Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. |
| 723 | 1 C x 630 sq. mm, Al |
| 724 | Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. |
| 725 | 1 C x 630 sq. mm, Al |
| 726 | LAYING OF CABLES |
| 727 | Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge |
| 728 | Cables with OD above 80 mm but upto 100 mm. |
| 729 | Cables with OD above 50 mm but upto 60 mm. |
| 730 | Cables with OD above 60 mm but upto 80 mm. |
| 731 | Cables with OD above 30 mm but upto 40 mm. |
| 732 | Cables with OD above 20 mm but upto 30 mm. |
| 733 | Cables with OD upto 20 mm. |
| 734 | Cables with OD above 40 mm but upto 50 mm. |
| 735 | Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge |
| 736 | Cables with OD upto 20 mm. |
| 737 | Cables with OD above 20 mm but upto 30 mm. |
| 738 | Cables with OD above 30 mm but upto 40 mm. |
| 739 | Cables with OD above 40 mm but upto 50 mm. |
| 740 | Cables with OD above 50 mm but upto 60 mm. |
| 741 | Cables with OD above 60 mm but upto 80 mm. |
| 742 | Cables with OD above 80 mm but upto 100 mm. |
| 743 | END TERMINATIONS |
| 744 | Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). |
| 745 | Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. |
| 746 | 3 Core cable Indoor termination kit for 6.6 kV240 mm² |
| 747 | 3 Core cable Outdoor termination kit for 6.6 kV240 mm² |
| 748 | 3 Core cable Indoor termination kit for 6.6 kV300 mm² |
| 749 | 3 Core cable Indoor termination kit for 11 kV300 mm² |
| 750 | 3 Core cable Indoor termination kit for 11 kV240 mm² |
| 751 | 1 Core cable Indoor termination kit for 6.6 kV630 mm² |
| 752 | 1 Core cable Indoor termination kit for 11 kV630 mm² |
| 753 | Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). |
| 754 | 3 Core cable termination kit for 6.6 kV300 mm² |
| 755 | 3 Core cable termination kit for 6.6 kV240 mm² |
| 756 | 3 Core cable termination kit for 11 kV300 mm² |
| 757 | 3 Core cable termination kit for 11 kV240 mm² |
| 758 | 1 Core cable termination kit for 6.6 kV630 mm² |
| 759 | 1 Core cable termination kit for 11 kV630 mm² |
| 760 | Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 761 | Cables with OD above 60 mm but upto 80 mm. |
| 762 | Cables with OD above 40 mm but upto 50 mm. |
| 763 | Cables with OD above 30 mm but upto 40 mm. |
| 764 | Cables with OD above 50 mm but upto 60 mm. |
| 765 | Cables with OD upto 20 mm. |
| 766 | Cables with OD above 20 mm but upto 30 mm. |
| 767 | Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 768 | All sizes from 1P to 4P and upto 2.5 sq. mm |
| 769 | All sizes from 5P to 10P and upto 2.5 sq. mm |
| 770 | All sizes from 11P to 15P and upto 2.5 sq. mm |
| 771 | STRAIGHT THROUGH JOINTS |
| 772 | Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 773 | Cables with OD above 30 mm but upto 40 mm. |
| 774 | Cables with OD above 50 mm but upto 60 mm. |
| 775 | Cables with OD above 60 mm but upto 80 mm. |
| 776 | Cables with OD upto 20 mm. |
| 777 | Cables with OD above 40 mm but upto 50 mm. |
| 778 | Cables with OD above 20 mm but upto 30 mm. |
| 779 | Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 780 | 3 Core cable Straight through jointing kits for 6.6 kV240 mm² |
| 781 | 3 Core cable Straight through jointing kits for 11 kV300 mm² |
| 782 | 1 Core cable Straight through jointing kits for 6.6 kV630 mm² |
| 783 | 1 Core cable Straight through jointing kits for 11 kV630 mm² |
| 784 | Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 785 | 3 Core cable Straight through jointing kits for 6.6 kV240 mm² |
| 786 | 3 Core cable Straight through jointing kits for 11 kV300 mm² |
| 787 | 1 Core cable Straight through jointing kits for 6.6 kV630 mm² |
| 788 | 1 Core cable Straight through jointing kits for 11 kV630 mm² |
| 789 | Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 790 | All sizes from 5P to 10P and upto 2.5 sq. mm |
| 791 | All sizes from 11P to 15P and upto 2.5 sq. mm |
| 792 | All sizes from 1P to 4P and upto 2.5 sq. mm |
| 793 | G.I. & PVC PIPES |
| 794 | Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 795 | 100 mm NB. |
| 796 | 150 mm NB. |
| 797 | 50 mm NB. |
| 798 | STRUCTURAL STEEL |
| 799 | Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). |
| 800 | CABLE - TRAYS |
| 801 | Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 802 | Reducers 750 - 450 RHS. |
| 803 | Reducers 750 - 600 RHS. |
| 804 | Reducers 750 - 600 LHS. |
| 805 | Horizontal bends for 450 mm wide tray with 1000 mm bending radius. |
| 806 | Horizontal bends for 600 mm wide tray with 1000 mm bending radius. |
| 807 | Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. |
| 808 | Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. |
| 809 | Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. |
| 810 | Tee Joints for 450 mm wide tray with 1000 mm bending radius. |
| 811 | Tee Joints for 600 mm wide tray with 1000 mm bending radius. |
| 812 | Tee Joints for 750 mm wide tray with 1000 mm bending radius. |
| 813 | Cross Joints for 450 mm wide tray with 1000 mm bending radius. |
| 814 | Cross Joints for 750 mm wide tray with 1000 mm bending radius. |
| 815 | Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. |
| 816 | 300 mm wide Straight run cable tray. |
| 817 | Horizontal bends for 750 mm wide tray with 1000 mm bending radius. |
| 818 | Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. |
| 819 | 600 mm wide Straight run cable tray. |
| 820 | Reducers 750 - 300 RHS. |
| 821 | Reducers 600 - 300 RHS. |
| 822 | Horizontal bends for 300 mm wide tray with 1000 mm bending radius. |
| 823 | Vertical outside bends for 300 mm wide tray with 1000 mm bending radius |
| 824 | Vertical inside bends for 300 mm wide tray with 1000 mm bending radius |
| 825 | Tee Joints for 300 mm wide tray with 1000 mm bending radius. |
| 826 | 450 mm wide Straight run cable tray. |
| 827 | 750 mm wide Straight run cable tray. |
| 828 | Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 829 | 150 mm wide. |
| 830 | 60 mm wide. |
| 831 | 100 mm wide. |
| 832 | Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 833 | CABLE GLANDS |
| 834 | Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 835 | Cables with OD above 50 mm but upto 60 mm. |
| 836 | Cables with OD above 30 mm but upto 40 mm. |
| 837 | Cables with OD above 40 mm but upto 50 mm. |
| 838 | Cables with OD above 60 mm but upto 80 mm. |
| 839 | Cables with OD above 20 mm but upto 30 mm. |
| 840 | Cables with OD upto 20 mm. |
| 841 | Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 842 | Cables with OD upto 20 mm. |
| 843 | Cables with OD above 20 mm but upto 30 mm. |
| 844 | Cables with OD above 30 mm but upto 40 mm. |
| 845 | Cables with OD above 40 mm but upto 50 mm. |
| 846 | Cables with OD above 50 mm but upto 60 mm. |
| 847 | Cables with OD above 60 mm but upto 80 mm. |
| 848 | Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 849 | Cables with OD upto 20 mm. |
| 850 | Cables with OD above 20 mm but upto 30 mm. |
| 851 | Cables with OD above 30 mm but upto 40 mm. |
| 852 | Cables with OD above 40 mm but upto 50 mm. |
| 853 | Cables with OD above 50 mm but upto 60 mm. |
| 854 | Cables with OD above 60 mm but upto 80 mm. |
| 855 | Cables with OD above 80 mm but upto 100 mm. |
| 856 | Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 857 | Cables with OD above 60 mm but upto 80 mm |
| 858 | Cables with OD above 30 mm but upto 40 mm |
| 859 | Cables with OD above 40 mm but upto 50 mm |
| 860 | Cables with OD above 50 mm but upto 60 mm |
| 861 | Cables with OD up to 20 mm |
| 862 | Cables with OD above 20 mm but upto 30 mm |
| 863 | MARKERS |
| 864 | Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. |
| 865 | Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 866 | CABLE LUGS |
| 867 | Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 868 | All sizes from 50 to 185 sq. mm |
| 869 | All sizes from 16 to 35 sq. mm |
| 870 | All sizes from 240 to 400 sq. mm |
| 871 | All sizes upto 10 sq. mm |
| 872 | All sizes from 500 to 1000 sq. mm |
| 873 | Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 874 | All sizes upto 10 sq. mm |
| 875 | All sizes from 240 to 400 sq. mm |
| 876 | All sizes from 16 to 35 sq. mm |
| 877 | All sizes from 50 to 185 sq. mm |
| 878 | All sizes from 500 to 1000 sq. mm |
| 879 | Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 880 | All sizes from 50 to 185 sq. mm |
| 881 | All sizes from 240 to 400 sq. mm |
| 882 | All sizes upto 10 sq. mm |
| 883 | All sizes from 16 to 35 sq. mm |
| 884 | All sizes from 500 to 1000 sq. mm |
| 885 | Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 886 | All sizes upto 10 sq. mm |
| 887 | All sizes from 16 to 35 sq. mm |
| 888 | All sizes from 240 to 400 sq. mm |
| 889 | All sizes from 50 to 185 sq. mm |
| 890 | All sizes from 500 to 1000 sq. mm |
| 891 | FIRE PROOFING OF CABLES |
| 892 | Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). |
| 893 | ADAPTORS / REDUCERS / NIPPLES ETC. |
| 894 | Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. |
| 895 | Eqpt. Thread 3/4\" PF (J.I.S.)-E.T. Thread 3/4\"ET |
| 896 | Eqpt. Thread 1\" PF (J.I.S.) - E.T. Thread 3/4\"ET |
| 897 | Eqpt. Thread 1\" PF (J.I.S.) -E.T. Thread 1\"ET |
| 898 | Eqpt. Thread 1-1/2\" PF (J.I.S.)- E.T. Thread 1-1/4\"ET |
| 899 | Eqpt. Thread 1-1/2\" PF (J.I.S.)- E.T. Thread 1-1/2\"ET |
| 900 | Eqpt. Thread 2\" PF (J.I.S.) -E.T. Thread 1-1/2\"ET |
| 901 | Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. |
| 902 | Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4\" ET |
| 903 | Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4\" ET |
| 904 | Eqpt. Thread PG 21 (DIN) -E.T. Thread 1\"ET |
| 905 | Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2\" ET |
| 906 | Eqpt. Thread 1\" ET (IS) -E.T. Thread 3/4\" ET |
| 907 | Eqpt. Thread 1-1/2\" ET (IS) -E.T. Thread 1\" ET |
| 908 | Eqpt. Thread 1-1/2\" ET (IS) -E.T. Thread 1-1/2\" ET |
| 909 | Eqpt. Thread 2\" ET (IS) -E.T. Thread 1-1/2\" ET |
| 910 | Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. |
| 911 | Eqpt. Thread 3/4\" PF (J.I.S.)-E.T. Thread 3/4\"ET |
| 912 | Eqpt. Thread 1\" PF (J.I.S.) -E.T. Thread 3/4\"ET |
| 913 | Eqpt. Thread 1\" PF (J.I.S.) -E.T. Thread 1\"ET |
| 914 | Eqpt. Thread 1-1/2\" PF (J.I.S.)- E.T. Thread 1-1/4\"ET |
| 915 | Eqpt. Thread 1-1/2\" PF (J.I.S.)- E.T. Thread 1-1/2\"ET |
| 916 | Eqpt. Thread 2\" PF (J.I.S.) -E.T. Thread 1-1/2\"ET |
| 917 | Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. |
| 918 | Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4\" ET |
| 919 | Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4\" ET |
| 920 | Eqpt. Thread PG 21 (DIN) -E.T. Thread 1\"ET |
| 921 | Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2\" ET |
| 922 | Eqpt. Thread 1\" ET (IS) -E.T. Thread 3/4\" ET |
| 923 | Eqpt. Thread 1-1/2\" ET (IS) -E.T. Thread 1\" ET |
| 924 | Eqpt. Thread 1-1/2\" ET (IS) -E.T. Thread 1-1/2\" ET |
| 925 | LIGHTING POLES |
| 926 | Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 927 | Lighting poles including supply and connection of wires upto fixtures for safe areas. |
| 928 | Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 929 | Lighting poles including supply and connection of wires upto fixtures for safe areas. |
| 930 | Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 931 | Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area |
| 932 | Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) |
| 933 | HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES |
| 934 | Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 935 | 3-way, junction box. |
| 936 | 4-way, junction box. |
| 937 | Well glass type pole mounting type for Ground Level. |
| 938 | Well glass type ceiling mounted. |
| 939 | Well glass type bracket mounted. |
| 940 | Well glass type pole mounting type for Platform. |
| 941 | Supply and installation of Type-`A\" clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 942 | Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 943 | Supply and installation of Type-`B\" clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 944 | SAFE AREA LIGHTING FIXTURES |
| 945 | Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. |
| 946 | Type LED SFD-12 Fixtures. |
| 947 | Type LED BK-3 Fixtures. |
| 948 | Type LED ST-10 Fixtures. |
| 949 | Type LED FD-1 Fixtures. |
| 950 | Type LED FD-2 Fixtures. |
| 951 | Type LED FD-3 Fixtures. |
| 952 | JUNCTION BOXES (OUTDOOR / INDOOR TYPE) |
| 953 | Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 954 | 3 way. |
| 955 | 4 way. |
| 956 | LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS |
| 957 | Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 958 | 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). |
| 959 | 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). |
| 960 | Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 961 | 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection |
| 962 | 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection |
| 963 | 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection |
| 964 | WIRING |
| 965 | Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 966 | 3 C x 2.5 sq. mm |
| 967 | 3 C x 4 sq. mm |
| 968 | Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 969 | 3 C x 2.5 sq. mm |
| 970 | EARTH ELECTRODES |
| 971 | Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 972 | GI earth electrode as per std. 7-51-0102. |
| 973 | COPPER EARTH ELECTRODES |
| 974 | Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge |
| 975 | EARTH STRIPS |
| 976 | Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 977 | 100 X 12 mm |
| 978 | 40 x 5 mm |
| 979 | 25 x 3 mm |
| 980 | 50 x 6 mm |
| 981 | Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 982 | 100 X 12 mm |
| 983 | 40 x 5 mm |
| 984 | 25 x 3 mm |
| 985 | 50 x 6 mm |
| 986 | EARTHING CONNECTION |
| 987 | Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 988 | 3/8\" dia (10 mm) flexible rope. |
| 989 | 5/8\" dia (16 mm) flexible rope. |
| 990 | 8 SWG GI Wire. |
| 991 | Supply and installation of 25 sq. mm (168/0.01772\") copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 992 | 300 mm |
| 993 | 500 mm |
| 994 | 1500 mm |
| 995 | EARTH PLATES |
| 996 | Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 997 | GI earth plate as per std. 7-51-0103. |
| 998 | EARTHING CONNECTORS |
| 999 | Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 1000 | Minimum 75mm to maximum 300 mm long |
| 1001 | Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 1002 | Minimum 75mm to maximum 300 mm long |
| 1003 | LIGHTNING RODS |
| 1004 | Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 1005 | GI lightning rod as per std. 7-51-0503. |
| 1006 | LAYING OF COMMUNICATION / FIRE ALARM CABLES |
| 1007 | Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge |
| 1008 | Cables of overall dia. above 35 mm. |
| 1009 | Cables of overall dia. upto 35 mm. |
| 1010 | Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge |
| 1011 | HDPE duct with overall dia. Upto 60mm |
| 1012 | HDPE duct with overall dia. above 60mm |
| 1013 | Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 1014 | Cables of overall dia. upto 40 mm. |
| 1015 | Cables of overall dia. above 40 mm. |
| 1016 | STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES |
| 1017 | Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 1018 | For Non-Jelly filled cables of size .9 mm5 pair |
| 1019 | For Non-Jelly filled cables of size .9 mm20 pair |
| 1020 | For Non-Jelly filled cables of size .9 mm10 pair |
| 1021 | For Jelly filled cables of size .63 mm²20 pair |
| 1022 | For Non-Jelly filled cables of size 1.5 mm²2 pair |
| 1023 | Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. |
| 1024 | 6 Fiber |
| 1025 | Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. |
| 1026 | 6 Fiber |
| 1027 | Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. |
| 1028 | 6 Fiber |
| 1029 | END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. |
| 1030 | Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. |
| 1031 | For Non-Jelly filled cables of size .9 mm5 pair |
| 1032 | For Non-Jelly filled cables of size .9 mm2 pair |
| 1033 | For Non-Jelly filled cables of size .9 mm50 pair |
| 1034 | For Non-Jelly filled cables of size .63 mm20 pair |
| 1035 | For Non-Jelly filled cables of size 1.5 mm2 pair |
| 1036 | For Non-Jelly filled cables of size 1.5 mm²2 pair |
| 1037 | Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge |
| 1038 | For 6 fiber Mono mode cable with LC pigtails and LC patch cords |
| 1039 | For 6 fiber Mono mode cable with SC pigtails and LC patch cords |
| 1040 | For 6 fiber Mono mode cable with ST pigtails and LC patch cords |
| 1041 | For 6 fiber Mono mode cable with LC pigtails and SC patch cords |
| 1042 | For 6 fiber Mono mode cable with LC pigtails and ST patch cords |
| 1043 | For 6 fiber Mono mode cable with SC pigtails and SC patch cords |
| 1044 | For 6 fiber Mono mode cable with SC pigtails and ST patch cords |
| 1045 | For 6 fiber Mono mode cable with ST pigtails and SC patch cords |
| 1046 | For 6 fiber Mono mode cable with ST pigtails and ST patch cords |
| 1047 | Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge |
| 1048 | 6 Fiber |
| 1049 | SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS |
| 1050 | Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. |
| 1051 | Jelly filled cables of size .9 mm20 pair |
| 1052 | Jelly filled cables of size .9 mm10 pair |
| 1053 | Non-Jelly filled cables of size .9 mm5 pair |
| 1054 | Non-Jelly filled cables of size .9 mm2 pair |
| 1055 | Non-Jelly filled cables of size 1.5 mm2 pair |
| 1056 | Non-Jelly filled cables of size .9 mm50 pair |
| 1057 | Non-Jelly filled cables of size .63 mm2 pair |
| 1058 | Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. |
| 1059 | 6 Fiber multitube construction |
| 1060 | Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. |
| 1061 | 6 Fiber multitube construction |
| 1062 | Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge |
| 1063 | HDPE duct with overall dia. Upto 60mm |
| 1064 | HDPE duct with overall dia. above 60mm |
| 1065 | CIVIL WORKS/M.S. CHEQUERED PLATE |
| 1066 | Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge |
| 1067 | Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). |
| 1068 | Excavation and backfilling of trenches in all types of soil including rock. |
| 1069 | Excavation and backfilling of trenches in all types of soil except rock. |
| 1070 | Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). |
| 1071 | 40 mm size gravel. |
| 1072 | Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. |
| 1073 | Fine river sand. |
| 1074 | Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). |
| 1075 | Bricks. |
| 1076 | Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. |
| 1077 | 6 mm thick M.S. chequered plate. |
| 1078 | Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. |
| 1079 | Rectangular Cut Out of length 200 mmwidth 200 mm |
| 1080 | Circular Cut Out of diameter 150 mm |
| 1081 | LAN SYSTEMS |
| 1082 | Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. |
| 1083 | Etherswitch Rack Type-I |
| 1084 | PAINTING & MARKING |
| 1085 | Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. |
| 1086 | Each alphabet/character above 2 inch and Upto 4 inch in height/length |
| 1087 | Each alphabet/character upto 2 inch in height/length |
| 1088 | Each alphabet/character above 4 inch and Upto 8 inch in height/length |
| 1089 | Each alphabet/character above 8 inch and Upto 12 inch in height/length |
| 1090 | Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. |
| 1091 | Each alphabet/character above 2 inch and Upto 4 inch in height/length |
| 1092 | Each alphabet/character upto 2 inch in height/length |
| 1093 | Each alphabet/character above 4 inch and Upto 8 inch in height/length |
| 1094 | Each alphabet/character above 8 inch and Upto 12 inch in height/length |
| 1095 | INSTRUMENTATION |
| 1096 | PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) |
| 1097 | Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. |
| 1098 | In Carbon Steel as per Standard 7-52-1103 |
| 1099 | In Carbon Steel as per Standard 7-52-4079. |
| 1100 | DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) |
| 1101 | Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration |
| 1102 | In Carbon Steel as per Standard 7-52-4077. |
| 1103 | In Carbon Steel as per Standard 7-52-4078. |
| 1104 | PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) |
| 1105 | Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 1106 | In Carbon Steel as per Standard 7-52-1101 |
| 1107 | In Carbon Steel as per Standard 7-52-1159 |
| 1108 | In Carbon Steel as per Standard 7-52-1188 |
| 1109 | In Carbon Steel as per Standard 7-52-1102 |
| 1110 | In Carbon Steel as per Standard 7-52-1163 |
| 1111 | In Stainless Steel as per Standard 7-52-1159 |
| 1112 | DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) |
| 1113 | Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 1114 | In Carbon Steel as per Standard 7-52-1140 |
| 1115 | In Carbon Steel as per Standard 7-52-1192 |
| 1116 | DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) |
| 1117 | Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 1118 | In Carbon Steel as per Standard 7-52-3489. |
| 1119 | In Carbon Steel as per Standard 7-52-3490. |
| 1120 | In Carbon Steel as per Standard 7-52-3491. |
| 1121 | In Stainless Steel as per Standard 7-52-3490. |
| 1122 | ULTRASONIC FLOWMETER |
| 1123 | Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. |
| 1124 | Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters |
| 1125 | DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) |
| 1126 | Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 1127 | In Carbon Steel as per Standard 7-52-1523. |
| 1128 | In Carbon Steel as per Standard 7-52-1524. |
| 1129 | LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) |
| 1130 | Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. |
| 1131 | In Carbon Steel as per Standard 7-52-1527 |
| 1132 | SERVO TYPE TANK GAUGES |
| 1133 | Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. |
| 1134 | Servo Gauge Installation |
| 1135 | RADAR LEVEL INSTRUMENTS |
| 1136 | Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. |
| 1137 | Installation of Top Mounted Radar |
| 1138 | Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. |
| 1139 | Tank Side Indicator |
| 1140 | TEMPERATURE INSTRUMENTS |
| 1141 | Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. |
| 1142 | Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells |
| 1143 | TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) |
| 1144 | Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. |
| 1145 | Temperature transmitter and RTD. |
| 1146 | Temperature Transmitter and RTD with flanged well |
| 1147 | Multipoint temperature transmitter with Thermocouple / RTD |
| 1148 | MISCELLANEOUS ITEMS AND DEVICES |
| 1149 | Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. |
| 1150 | ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. |
| 1151 | Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. |
| 1152 | Weather proof Push Button Station/ Selector Switches. |
| 1153 | Corrosion Transmitters |
| 1154 | CALIBRATION/ TESTING |
| 1155 | Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration |
| 1156 | Control Valves |
| 1157 | Self Actuated Pressure reducing valves |
| 1158 | Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. |
| 1159 | Sizes upto 3/4\" x 1\" threaded |
| 1160 | Inlet Sizes upto 2\" flanged, rating 150# to 2500# |
| 1161 | Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. |
| 1162 | Pressure gauges |
| 1163 | Pressure transmitters |
| 1164 | Differential Pressure Gauges |
| 1165 | Differential Pressure Transmitters for Flow, Level and D.P. |
| 1166 | Temperature gauges |
| 1167 | Temperature Transmitters |
| 1168 | Tank Level Instrument (Radar type) |
| 1169 | Servo Type Tank Gauges |
| 1170 | Electronic Local Indicator |
| 1171 | Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. |
| 1172 | Ultrasonic flowmeters |
| 1173 | LOOP CHECKING |
| 1174 | Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. |
| 1175 | Pressure transmitters |
| 1176 | Differential Pressure Transmitters for Flow, Level and D.P. |
| 1177 | Temperature Transmitters |
| 1178 | Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments |
| 1179 | Tank Level Instruments (Radar type) |
| 1180 | Electronic Local Indicator |
| 1181 | Speed / Vibration Transmitter |
| 1182 | Push Button/Selector Switches/Lamps |
| 1183 | Control valve positioner |
| 1184 | Corrosion Transmitter |
| 1185 | Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. |
| 1186 | Ultrasonic flowmeters |
| 1187 | SUPPLY ITEMS |
| 1188 | Supply of Instrument items as per specifications enclosed elsewhere in the Tender. |
| 1189 | 24\" Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. |
| 1190 | 2\"/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. |
| 1191 | 3\"/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. |
| 1192 | 4\"/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. |
| 1193 | Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. |
| 1194 | Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. |
| 1195 | Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1196 | Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1197 | Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1198 | Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1199 | Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1200 | Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1201 | Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1202 | Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1203 | Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1204 | Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1205 | Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. |
| 1206 | 24 V DC loop powered spare corrosion Transmitter. |
| 1207 | Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6\" Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1208 | Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6\" Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1209 | Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8\" Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1210 | Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6\" Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1211 | Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6\" Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1212 | Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8\" Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1213 | Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8\" Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1214 | Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6\" Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2\" cable entry connectionfor signal & 3/4\" cable entry connection for power (if applicable). |
| 1215 | Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. |
| 1216 | 2\"/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. |
| 1217 | Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. |
| 1218 | Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. |
| 1219 | Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. |
| 1220 | Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. |
| 1221 | Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. |
| 1222 | Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. |
| 1223 | Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. |
| 1224 | Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. |
| 1225 | Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. |
| 1226 | Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. |
| 1227 | Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. |
| 1228 | Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. |
| 1229 | Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. |
| 1230 | Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. |
| 1231 | Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. |
| 1232 | Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. |
| 1233 | Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. |
| 1234 | Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. |
| 1235 | Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. |
| 1236 | Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. |
| 1237 | Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. |
| 1238 | Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. |
| 1239 | Signal cableXLPE insulatedFRLS 12PX1.5 mm2 |
| 1240 | Signal cableXLPE insulatedFRLS 1PX1.5 mm2 |
| 1241 | Supply of Junction boxes of various types and specifications |
| 1242 | Junction Box, Weatherproof type for 12 Pair Cable |
| 1243 | Junction Box, Weatherproof type for 3 Way |
| 1244 | Supply of Cable glands ofvarioustypes and specifications |
| 1245 | Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2\" NPTM |
| 1246 | Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2\" NPTM |
| 1247 | Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4\" NPTM |
| 1248 | Supply of plugs for cable entries of varioustypes and specifications |
| 1249 | Plug ,weatherproof type, SS 304 material, 1/2\" NPTM |
| 1250 | Plug ,weatherproof type, SS 304 material, 1 1/2\" NPTM |
| 1251 | Plug ,weatherproof type, SS 304 material, 3/4\" NPTM |
| 1252 | Supply of compression tube fittings in Stainless Steel of various types and specifications |
| 1253 | Male Connector: Material: SS-316 : Size: 1/2\" NPTM X 1/2\" OD 153 Bar |
| 1254 | Male Connector: Material: SS-316 : Size: 1/4\" NPTM X 1/4\" OD 153 Bar |
| 1255 | Male Connector: Material: SS-316 : Size: 1/2\" NPTM X 1/4\" OD 153 Bar |
| 1256 | SS 316 Ball Valve 1/2\" TH 41 Bar. |
| 1257 | Tube Union: Material: SS-316 ; Size: 1/2\" OD x 1/2\" OD 153 Bar |
| 1258 | Tube Cap; Material: SS-316 ; Size : 1/2\" OD 153 Bar |
| 1259 | 6 Way Air Manifold SS316 |
| 1260 | Supply of instrument tubes of different types and specifications |
| 1261 | SS316L tube 1/2\" OD 153 Bar |
| 1262 | SS316L tube 1/4\" OD 153 Bar |
| 1263 | Supply of pipe and pipe fittings |
| 1264 | SS316 Pipe 1\" PL End, SCH. 40S |
| 1265 | 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. |
| 1266 | SS316 Nipple 1/2\" TH x TH, SCH. 80S |
| 1267 | SS316 Nipple 1\" TH x PL, SCH. 40S |
| 1268 | SS316 Nipple 1\" PL x PL, SCH. 40S |
| 1269 | SS316 Equal Tee 1\" SW, 3000# |
| 1270 | SS316 Elbow 1” SW, 3000# |
| 1271 | SS316 Cap 1/2” TH, 3000# |
| 1272 | SS316 Cap 1” TH, 3000# |
| 1273 | SS316 Coupling full 1” SW, 3000# |
| 1274 | SS316 Globe Valve 1\" SW, body rating: 800#, end rating: 3000# |
| 1275 | JUNCTION BOX INSTALLATION |
| 1276 | Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. |
| 1277 | Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² |
| 1278 | LAYING OF CABLES |
| 1279 | Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. |
| 1280 | Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² |
| 1281 | Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² |
| 1282 | Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench |
| 1283 | For cable size 2C x 2.5 mm² |
| 1284 | EARTHING |
| 1285 | Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. |
| 1286 | At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. |
| 1287 | PIPING / TUBING / FABRICATION WORK |
| 1288 | Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard |
| 1289 | For size 1\" |
| 1290 | Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray |
| 1291 | 1/2\" / 12 mm O.D . (for SS tubes) |
| 1292 | Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings |
| 1293 | Installation of 6-way Air Manifold (1/2\") as per Standard 7-52-1905 |
| 1294 | Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards |
| 1295 | as per standard 7-52-3982. |
| 1296 | RADIOGRAPHY - CARBON STEEL WELD JOINTS |
| 1297 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges |
| 1298 | In Carbon Steel as per Standard 7-52-1103. |
| 1299 | In Carbon Steel as per Standard 7-52-4079. |
| 1300 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge |
| 1301 | In Carbon Steel as per standard 7-52-4077. |
| 1302 | In Carbon Steel as per standard 7-52-4078. |
| 1303 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations |
| 1304 | In Carbon Steel as per Standard 7-52-1101. |
| 1305 | In Carbon Steel as per Standard 7-52-1159. |
| 1306 | In Carbon Steel as per Standard 7-52-1188. |
| 1307 | In Carbon Steel as per Standard 7-52-1102. |
| 1308 | In Carbon Steel as per Standard 7-52-1163. |
| 1309 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments |
| 1310 | In Carbon Steel as per Standard 7-52-1140. |
| 1311 | In Carbon Steel as per Standard 7-52-1192. |
| 1312 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments |
| 1313 | In Carbon Steel as per Standard 7-52-3489. |
| 1314 | In Carbon Steel as per Standard 7-52-3490. |
| 1315 | In Carbon Steel as per Standard 7-52-3491. |
| 1316 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments |
| 1317 | In Carbon Steel as per Standard 7-52-1523. |
| 1318 | In Carbon Steel as per Standard7-52-1524. |
| 1319 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges |
| 1320 | In Carbon Steel as per Standard 7-52-1527. |
| 1321 | RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS |
| 1322 | Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. |
| 1323 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations |
| 1324 | In Stainless Steel as per Standard 7-52-1159. |
| 1325 | Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments |
| 1326 | In Stainless Steel as per Standard 7-52-3490. |
| 1327 | Fire protection of instrument cable duct/trays |
| 1328 | Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender |
| 1329 | Run of Duct 600mm(W) X 300mm(H) |
| 1330 | Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender |
| 1331 | Run of Tray 100mm (W) X 30mm (H) |
| 1332 | Run of Tray 60 mm (W) X 20mm (H) |
| 1333 | Run of Tray 150 mm (W) X 75 mm (H) |
| 1334 | Run of Tray 300 mm (W) X 75 mm (H) |
| 1335 | STRUCTURAL |
| 1336 | Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. |
| 1337 | Run of Duct 1000mm (W) X 400mm (H) |
| 1338 | Run of Duct 600mm (W) X 300mm (H) |
| 1339 | Run of Duct 800mm (W) X 300mm (H) |
| 1340 | Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows |
| 1341 | tray of 60 mm (W) X 20 mm (H) |
| 1342 | tray of 150 mm (W) X 75 mm (H) |
| 1343 | tray of 300 mm (W) X 75 mm (H) |
| 1344 | tray of 100 mm (W) X 30 mm (H) |
| 1345 | CANOPY FOR INSTRUMENTS AND JUNCTION BOXES |
| 1346 | Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 |
| 1347 | FRP Canopy (All sides closed) - Field Instruments |
| 1348 | FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator |
| 1349 | FRP Canopy For Junction Box - Front Side Open |
| 1350 | FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter |
| 1351 | FRP Canopy for RTD / Thermocouple |
| 1352 | Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 |
| 1353 | FRP Canopy (All sides closed) - Field Instruments |
| 1354 | FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator |
| 1355 | FRP Canopy For Junction Box - Front Side Open |
| 1356 | FRP Canopy for RTD / Thermocouple |
| 1357 | FRP Canopy (All Side Closed) - Radar Level Instruments |
| 1358 | GENERAL SITE WORK |
| 1359 | Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. |
| 1360 | 2\" Yoke supports as per standard 7-52-0101 |
| 1361 | Erection of 2\" Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. |
| 1362 | Erection of2\" Yoke supports for instruments excluding supply of Yoke |
| 1363 | Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). |
| 1364 | Structural steel ISMC 100 |
| 1365 | Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. |
| 1366 | Identification of instrument items |
| 1367 | Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached |
| 1368 | Size 500 mm x 500 mm x 600 mm |
| 1369 | SITE ACTIVITIES BY MECHANICAL CONTRACTOR |
| 1370 | Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2\" impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. |
| 1371 | Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2\" impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. |
| 1372 | Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owner\"s storage points to contractor\"s stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. |
| 1373 | Inlet Valve size - 12\" , Rating - 300# |
| 1374 | Inlet Valve size - 1\" , Rating - 300# |
| 1375 | Inlet Valve size - 1 1/2\" , Rating - 300# |
| 1376 | Inlet Valve size - 3\" , Rating - 300# |
| 1377 | Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owner\"s storage point to contractor\"s store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. |
| 1378 | Inlet size - 1\" , Rating - 150# |
| 1379 | Inlet size - 2\" , Rating - 150# |
| 1380 | Inlet size - 4\" , Rating - 150# |
| 1381 | Inlet size - 3/4\" , Rating - NPT |
| 1382 | Impulse line painting (uninsulated) as per painting specification for project |
| 1383 | Instrumentation impulse line of size 1/2\" for temp. (-)14 to 80 degC |
| 1384 | Impulse line painting (insulated) as per EIL painting specification for project. |
| 1385 | Impulse line size of 1/2\" with material Carbon Steel for temp. (-)45 to 125 degC |
| 1386 | ENVIRONMENT |
| 1387 | Condensate Water Treatment Plant |
| 1388 | CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. |
| 1389 | EQUIPMENT - PACKAGE |
| 1390 | Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. |
| 1391 | BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 |
| 1392 | BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 |
| 1393 | BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 |
| 1394 | BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 |
| 1395 | BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 |
| 1396 | Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendor\"s works to site, unloading at site, handling, transportation to contractor\"s store and from contractor\"s store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. |
| 1397 | Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) |
| 1398 | EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturer\"s shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendor\"s works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). |
| 1399 | 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, \"M5\" duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). |
| 1400 | UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE |
| 1401 | Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) |
| 1402 | Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). |
| 1403 | Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. |
| 1404 | EQUIPMENT - ROTATING |
| 1405 | Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owner\"s storage points to work site / contractor\"s stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufacture\"s / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). |
| 1406 | Pump Packages (all types) with drivers, auxiliaries and accessories. |
| 1407 | All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). |
| 1408 | Chemical Dosing Packages |
| 1409 | Skid mounted chemical dosing packages along with all auxiliaries and accessories. |
| 1410 | Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owner\"s storage points to work site / contractor\"s stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufacture\"s / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). |
| 1411 | Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. |
| 1412 | Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 |
| 1413 | EQUIPMENT - STATIC |
| 1414 | STORAGE TANKS |
| 1415 | PLATE WORK |
| 1416 | Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractor\"s scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. |
| 1417 | IS 2062 Gr. E250 (A, BR, B0, C) |
| 1418 | SA 516 Gr. 60/ 70 |
| 1419 | STRUCTURAL/PIPES |
| 1420 | STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. |
| 1421 | Roof structure as per Standard/Drg. |
| 1422 | SA 36 |
| 1423 | IS 2062 |
| 1424 | SA 516 Gr.60/70 |
| 1425 | STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. |
| 1426 | SA 333 GR6 |
| 1427 | SA 106 Gr. B |
| 1428 | STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. |
| 1429 | PIPES(CS GALVANIZED) |
| 1430 | APPURTENANCES |
| 1431 | Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractor\"s scope of supply and shall be included in nozzle assembly quoted price. |
| 1432 | Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material |
| 1433 | Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material |
| 1434 | Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material |
| 1435 | Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material |
| 1436 | Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material |
| 1437 | Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material |
| 1438 | Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material |
| 1439 | Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material |
| 1440 | Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material |
| 1441 | Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material |
| 1442 | Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material |
| 1443 | Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material |
| 1444 | Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material |
| 1445 | GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. |
| 1446 | Size 2 InchMaterial SA 106 Gr. B |
| 1447 | INSTRUMENTS |
| 1448 | Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). |
| 1449 | Pressure Transmitter Instrument |
| 1450 | Level Transmitter Instrument |
| 1451 | Breather Valve Instrument |
| 1452 | Emergency Vent Instrument |
| 1453 | Temperature Gauge Instrument |
| 1454 | CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge |
| 1455 | Diameter (Meters) : upto 10 Height (Meters) : upto10 |
| 1456 | Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 |
| 1457 | DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer\"s works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. |
| 1458 | DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer\"s works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. |
| 1459 | Gauge Hatch with Cover:Supply & installation of \"Gauge Hatch with Cover\" for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. |
| 1460 | Material: CS |
| 1461 | PAINTING OF TANKS |
| 1462 | PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS |
| 1463 | ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. |
| 1464 | Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 |
| 1465 | ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. |
| 1466 | Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. |
| 1467 | Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron |
| 1468 | InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. |
| 1469 | Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - |
| 1470 | Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - |
| 1471 | EQUIPMENT ERECTION |
| 1472 | TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL |
| 1473 | Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. |
| 1474 | EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owner\"s storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. |
| 1475 | Equipment weighing less than 30 MT but 10 MT and above |
| 1476 | TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL |
| 1477 | Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. |
| 1478 | EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. |
| 1479 | Equipment weighing less than 50 MT but 30 MT and Above |
| 1480 | Equipment weighing less than 30 MT but 10 MT and above |
| 1481 | LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. |
| 1482 | ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owner\"s storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. |
| 1483 | Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above |
| 1484 | ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owner\"s storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. |
| 1485 | Equipment weighing less than 30 MT but 10 MT and Above |
| 1486 | WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. |
| 1487 | MOC : Carbon Steel ,Nozzle size : 2\" |
| 1488 | MOC : Carbon Steel ,Nozzle size : 3\" |
| 1489 | MOC : Carbon Steel ,Nozzle size : 6\" |
| 1490 | MOC : Carbon Steel ,Nozzle size : 8\" |
| 1491 | MOC : Carbon Steel ,Nozzle size : 20\" |
| 1492 | MOC : Carbon Steel ,Nozzle size : 24\" |
| 1493 | EQUIPMENT INSULATION |
| 1494 | COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. |
| 1495 | Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. |
| 1496 | Insulation Thickness: 50mm |
| 1497 | Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. |
| 1498 | Insulation Thickness: 50mm |
| 1499 | STRUCTURAL |
| 1500 | EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) |
| 1501 | Earthwork excavation in soil |
| 1502 | Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. |
| 1503 | Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. |
| 1504 | Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. |
| 1505 | Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. |
| 1506 | SHORING AND STRUTTING |
| 1507 | Providing and installing approved type of \"SHORING AND STRUTTING\" by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. |
| 1508 | Providing and installing approved type of \"SHORING AND STRUTTING\" by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. |
| 1509 | Backfilling after execution of work |
| 1510 | BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. |
| 1511 | BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. |
| 1512 | Transporting & Disposing the SURPLUS EARTH ANDDEBRIS |
| 1513 | Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). |
| 1514 | Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). |
| 1515 | PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) |
| 1516 | PCC - Non FIM Items |
| 1517 | Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. |
| 1518 | Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. |
| 1519 | RCC Substrutures - Non FIM Items |
| 1520 | Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. |
| 1521 | Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. |
| 1522 | RCC Superstructures - Non FIM Items |
| 1523 | Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. |
| 1524 | HYD Bars / MS Bars - Non FIM Items |
| 1525 | Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTOR\"S SCOPE. |
| 1526 | Centering and Shuttering - Non FIM Items |
| 1527 | Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. |
| 1528 | Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. |
| 1529 | Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. |
| 1530 | Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. |
| 1531 | Fixing Re-bars in already cast concrete - Non FIM Items |
| 1532 | Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturer\"s recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTOR\"S SCOPE EXCLUDING REINFORCEMENT BARS. |
| 1533 | CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 |
| 1534 | RCC- Non FIM Items |
| 1535 | Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. |
| 1536 | Water Proofing Comp. - Non FIM Items |
| 1537 | Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturer\"s specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. |
| 1538 | PVC Water bars - Non FIM Items |
| 1539 | Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturer\"s specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. |
| 1540 | Separation Layer - NonFIM Item |
| 1541 | Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. |
| 1542 | STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 |
| 1543 | General Steel Works - FIM Items |
| 1544 | Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTOR\"S SCOPE. |
| 1545 | General Steel Works - Non FIM Items |
| 1546 | Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR\"S SCOPE. |
| 1547 | Painting - Non FIM Items |
| 1548 | Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTOR\"S SCOPE. (Unit rate based on Structural steel weight). |
| 1549 | Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR\"S SCOPE. (Unit rate based on weight of steel). |
| 1550 | STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) |
| 1551 | Yst310 IS 4923 |
| 1552 | \"Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using \"\"COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make\"\" in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTOR\"S SCOPE) |
| 1553 | MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 |
| 1554 | Anchor Bolts - Non FIM Items |
| 1555 | Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE). |
| 1556 | MS Metal Inserts - Non FIM Items |
| 1557 | Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE). |
| 1558 | GI Pipe Sleeves - Non FIM Items |
| 1559 | Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. |
| 1560 | MS Chequered Plates - Non FIM Items |
| 1561 | Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE). |
| 1562 | MS Grating Cat. A,B - Non FIM Items |
| 1563 | Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTOR\"S SCOPE). |
| 1564 | Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturer\"s supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE. |
| 1565 | Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. |
| 1566 | MS Rungs - Non FIM Items |
| 1567 | Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE). |
| 1568 | Hand Railing 1000mm - Non FIM Items |
| 1569 | Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). |
| 1570 | Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). |
| 1571 | Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTOR\"S SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) |
| 1572 | Mechanical Anchor fastners - Non FIM Items |
| 1573 | \"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer\"s specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\" |
| 1574 | \"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer\"s specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\" |
| 1575 | Chemical Anchor Fastner |
| 1576 | \"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer\"s specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\" |
| 1577 | \"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer\"s specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\" |
| 1578 | \"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer\"s specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.\" |
| 1579 | Threaded bolts for equipment fixing-Non FIM |
| 1580 | Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTOR\"S SCOPE). |
| 1581 | BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) |
| 1582 | CLASS 5.0at all depths -Non FIM Items |
| 1583 | Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. |
| 1584 | Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. |
| 1585 | HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items |
| 1586 | Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. |
| 1587 | DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) |
| 1588 | Brickwork - Non FIM Items |
| 1589 | Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). |
| 1590 | Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. |
| 1591 | RCC - Non FIM Items |
| 1592 | Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). |
| 1593 | Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. |
| 1594 | Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). |
| 1595 | Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. |
| 1596 | Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. |
| 1597 | Pockets - Non FIM Items |
| 1598 | Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. |
| 1599 | PCC _ Non FIM Items |
| 1600 | Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) |
| 1601 | Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). |
| 1602 | Steelwork - Non FIM Items |
| 1603 | Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. |
| 1604 | MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) |
| 1605 | Anticorrosive - Non FIM Items |
| 1606 | Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. |
| 1607 | Sand Filling - Non FIM Items |
| 1608 | Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . |
| 1609 | BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE |
| 1610 | Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturer\"s specification for protection of reinforcement against corrosion. Supply of admixture in Contractor\"s scope. |
| 1611 | BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) |
| 1612 | Epoxy Resin - non FIM Items |
| 1613 | Providing and applying approved EPOXY RESIN (prepared as per manufacturer\"s recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). |
| 1614 | FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) |
| 1615 | Concrete - Non FIM Items |
| 1616 | Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). |
| 1617 | Vermiculite Concrete for Structural Steel - Non-FIM Items |
| 1618 | Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). |
| 1619 | Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). |
| 1620 | Vermiculite Concrete for Equipments - Non-FIM Items |
| 1621 | Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). |
| 1622 | Mechanical works |
| 1623 | Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. |
| 1624 | SAFETY (REFER EIL SPECIFICATION) |
| 1625 | Safety Structures - Non FIM Items |
| 1626 | Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractor\"s Scope). |
| 1627 | Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. |
| 1628 | Supply of Safety Personnel |
| 1629 | Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). |
| 1630 | Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). |
| 1631 | Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). |
| 1632 | Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). |
| 1633 | GENERAL CIVIL |
| 1634 | TANK PADS |
| 1635 | PVC Liner |
| 1636 | Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturer\"s recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractor\"s scope of supply) |
| 1637 | Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractor\"s scope of supply) |
| 1638 | Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. |
| 1639 | GENERAL CIVIL |
| 1640 | SITE GRADING & ROCK CUTTING FOR SITE GRADING |
| 1641 | Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. |
| 1642 | ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) |
| 1643 | Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. |
| 1644 | Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. |
| 1645 | Supply of forged/ cast fittings |
| 1646 | Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owner\"s stores/workspot etc. all complete as per the directions of Engineer-in- Charge. |
| 1647 | Elbow 90 Degree for following Nominal Sizes and Piping Material Class |
| 1648 | Dia. 12 InchPipe Class A33A |
| 1649 | Dia. 3 InchPipe Class A91A |
| 1650 | Elbow 45 Degree for following Nominal Sizes and Piping Material Class |
| 1651 | Dia. 6 InchPipe Class A33A |
| 1652 | Dia. 8 InchPipe Class A33A |
| 1653 | Dia. 12 InchPipe Class A33A |
| 1654 | Dia. 3 InchPipe Class A91A |
| 1655 | Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class |
| 1656 | Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A |
| 1657 | Equal Tees for following Nominal Sizes and Piping Material Class |
| 1658 | Dia. 12 InchPipe Class A33A |
| 1659 | Dia. 3 InchPipe Class A91A |
| 1660 | Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class |
| 1661 | Dia. 3 InchPipe Class A91A |
| 1662 | Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class |
| 1663 | Dia. 3 InchPipe Class A91A |
| 1664 | MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS |
| 1665 | Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. |
| 1666 | All materials including cement supplied by the Contractor and Following Brick Class |
| 1667 | Brick Class 5 |
| 1668 | Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. |
| 1669 | All materials including cement supplied by the Contractor. |
| 1670 | MISCELLANEOUS ITEMS |
| 1671 | Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. |
| 1672 | Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category \"A\" as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). |
| 1673 | Modification Works |
| 1674 | MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owner\"s storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge |
| 1675 | Flame cutting CS piping |
| 1676 | Beveling CS piping |
| 1677 | Fit-up and welding CS piping |
| 1678 | Removal and re-installation of fire hydrant |
| 1679 | Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) |
| 1680 | NDT Testing |
| 1681 | RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractor\"s fault and for additional radiography necessitated due to poor performance of contractor\"s welders shall be done at contractor\"s cost) Note: Unit for radiography quantity is \"Nos of circumferential weld joints\". |
| 1682 | FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) |
| 1683 | Nominal Dia. 3 Inch |
| 1684 | Nominal Dia. 4 Inch |
| 1685 | Nominal Dia. 6 Inch |
| 1686 | Nominal Dia. 8 Inch |
| 1687 | Nominal Dia. 12 Inch |
| 1688 | Micrograding |
| 1689 | Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) |
| 1690 | Dismantling works |
| 1691 | Removal of existing A/G piping |
| 1692 | Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owner\"s storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. |
| 1693 | For C.S. A/G Pipe of following nominal dia. |
| 1694 | Nominal Dia 8 Inch |
| 1695 | Nominal Dia 4 Inch |
| 1696 | Nominal Dia 6 Inch |
| 1697 | Nominal Dia 12 Inch |
| 1698 | Removal of existing U/G piping |
| 1699 | Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owner\"s storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. |
| 1700 | For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes |
| 1701 | NB 2 inch - 6 inch |
| 1702 | NB 8 inch - 14 inch |
| 1703 | Portable/ trolley mounted Extinguishers |
| 1704 | Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. |
| 1705 | Capacity in Kg 10 |
| 1706 | Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. |
| 1707 | Capacity in Kg 4.5 |
| 1708 | Capacity in Kg 2 |
| 1709 | Painting of A/G pipes and valves |
| 1710 | Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. |
| 1711 | Painting of uninsulated surfaces for \" Industrial marine \" environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes |
| 1712 | Nominal Dia. 12 Inch |
| 1713 | Nominal Dia. 4 Inch |
| 1714 | Nominal Dia. 3 Inch |
| 1715 | Nominal Dia. 6 Inch |
| 1716 | Nominal Dia. 8 Inch |
| 1717 | Painting of uninsulated surfaces for \" Industrial marine \" environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes |
| 1718 | Dia. Of Valve 12 Inch |
| 1719 | Dia. Of Valve 4 Inch |
| 1720 | Dia. Of Valve 6 Inch |
| 1721 | Dia. Of Valve 3 Inch |
| 1722 | Dia. Of Valve 8 Inch |
| 1723 | Fabrication and Erection of piping (underground) |
| 1724 | FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owner\"s storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owner\"s storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) |
| 1725 | Carbon SteelPiping (Non IBR), Thickness <=10 mm |
| 1726 | Fabrication, For the following nominal sizes |
| 1727 | NB 2 inch - 6 inch |
| 1728 | NB 8 inch - 14 inch |
| 1729 | Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes |
| 1730 | NB 2 inch - 6 inch |
| 1731 | NB 8 inch - 14 inch |
| 1732 | Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes |
| 1733 | NB 2 inch - 6 inch |
| 1734 | Fabrication and Erection of piping (Above ground) |
| 1735 | PIPING (ABOVE GROUND): Transportation of all piping items from owner\"s storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) |
| 1736 | Carbon SteelPiping (Non IBR), Thickness <=10 mm |
| 1737 | Fabrication, For the following nominal sizes |
| 1738 | NB 2 inch - 6 inch |
| 1739 | NB 8 inch -14 inch |
| 1740 | Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes |
| 1741 | NB 2 inch - 6 inch |
| 1742 | NB 8 inch -14 inch |
| 1743 | Supply of Carbon steel pipes |
| 1744 | Supply of Carbon steel pipes as per Piping material class including transportation of all material to owner\"s store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. |
| 1745 | Nominal Dia. 12 InchPiping Material Class A33A |
| 1746 | Nominal Dia. 4 InchPiping Material Class A33A |
| 1747 | Nominal Dia. 8 InchPiping Material Class A33A |
| 1748 | Nominal Dia. 6 InchPiping Material Class A33A |
| 1749 | Nominal Dia. 3 InchPiping Material Class A91A |
| 1750 | Supply and installation of valve assembly, flange assembly etc. |
| 1751 | Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. |
| 1752 | Gate valve assembly for following nominal sizes and piping material class |
| 1753 | Dia. 12 InchPMS A33A |
| 1754 | Dia. 8 InchPMS A33A |
| 1755 | Dia. 6 InchPMS A33A |
| 1756 | Dia. 3 InchPMS A91A |
| 1757 | Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. |
| 1758 | Dia. 4 InchPMS A33A |
| 1759 | Dia. 6 InchPMS A33A |
| 1760 | Globe valve assembly for following nominal sizes and piping material class |
| 1761 | Dia. 3 InchPMS A91A |
| 1762 | Supplying the flange assembly conforming to piping material specifications and delivering the same to owner\"s stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class |
| 1763 | Dia. 3 InchPMS A91A |
| 1764 | Supply, Fabrication and installation of strainers |
| 1765 | Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. |
| 1766 | T-type strainers for following nominal size and piping material class |
| 1767 | Dia. 3 InchPMS A91A |
| 1768 | fire fighting equipment\"s |
| 1769 | Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. |
| 1770 | Double headed landing valve |
| 1771 | First Aid hose reel wall mounted type |
| 1772 | Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall |
| 1773 | Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall |
| 1774 | Variable flow Water cum foam monitor of 500/750/1000 GPM capacity |
| 1775 | Stand Post Type Fire Hydrant without Pumper Connection |
| 1776 | Miscellaneous Items |
| 1777 | Miscellaneous |
| 1778 | Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy