| 1 | Rehabilitation and waterproofing treatment to AdmBuilding tower andPhysics Department Building at VNIT , Nagpur |
| 2 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.Spec.No. As directed by Engineer in charge. |
| 3 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. Spec.No. As directed by Engineer in charge. |
| 4 | Removing cement mortar, tiles,or marble or polished shahabad floor or dado with out bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 5 | Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing in let tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. Spec.No. As directed by Engineer in charge. |
| 6 | Filling voids / honey comb with high pressure injection grouting of Polymer Cement Grout (10% of Polymer by Weight of Cement)Spec.No. As directed by Engineer in charge. |
| 7 | Providing Water proofing treatment to old terraces by removing existing treatment, sealing of cracks by non shrink crack fill compound applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1:2 proportion (1 litre polymer : 2 Kilogram Cement) or Rohnex water proofing system in two coats (1 Kilogram powder, 700 ml water and polymer jelly for first coat & 1 Kilogram powder, 500 ml water & polymer jelly for second coat) to a neatly cleaned and dust free concrete surface and upto 300 mm over parapet wall prepared by removing loose and deposited material with brush and water, followed by two coat of flexible cementious coating of approved make after laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coating transverse direction, sprinkling coarses and over it, followed by protective mechanical cover of 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make along with 14 guage 40 mm x 40 mm size welded mesh and polyprpylene fibres @ 125 gm per bag of cement within it conforming to IS in pannels of 3m/4m or as per site condition & filling the joints with polt sulphide sealant (0.12 Kilogram per sq.mt.) after curing, including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry including curing as directed and ponding the surface as directed etc. complete; covering 10 years guarantee against leakproofness on Court Fee Stamp Paper of Rs. 100/- |
| 8 | Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / granite / quartzite / gneiss metal for R.C.C. coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centring, form work, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec.No. As directed by Engineer in charge. |
| 9 | Anticorrosive treatment to expose reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush.Spec.No. As directed by Engineer in charge. |
| 10 | Providing and applying Kelox R 101 (Resin) + Kelox H 404 (Hardner) water misible epoxy of approved make for bonding old concrete to new mortar after mixing slowely in predefined ratio and applying by brush on the surfac, when it is tacky then apply the mortar complete as per specification and as directed by engineer-in-charge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500 /- stamp paper.Spec.No. As directed by Engineer in charge. |
| 11 | Providing and applying 30 mm thick self curing Ceremic Polymer Micro concrete of approved make having Compressive strength above M30, non shrink, impermeable, filling mortar to load carrying R.C.C member in two layers on cleaned concrete surface, including honey comb area (using manual / mechanical means). Mixing mortar of Nicosil C80 and fresh 53 grade cement with required water cement ratio for desired consistency and applying and finishing by manual trawelling, curing after curing initial setting time etc, as per manufacturers specification etc. complete as per specification and as directed by engineer-in-charge. Work shall be executedby certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500/- stamp paper. (Bond coat mentioned below is to bed one before coating) Spec.No. As directed by Engineer in charge. |
| 12 | Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including perma plast-o-proof compound @ 100 ml per bag , scaffolding and curing etc.complete. Spec.No. As directed by Engineer in charge. |
| 13 | Providing and applying elastomeric liquid applied acrylic coating with fibers as waterproofing membrance on terrace and parapet wall including cleaning the surface of dust, loose etc and applied in two coats etc complete. |
| 14 | Providing expansion joints treatment in RCC framed structure (at terrace level) with cleaning the surface repairing all edges with polymer mortar with bonding coat, applying polymer coating with fiber mesh filling expansion joint with back up rod after applying primer and filling polysulphide in the gap of joints drilling of holes for fixing and providingreinforcement and Casting CC M-20 grade concrete for beams and slabs with hauller and plaster etc. complete. |
| 15 | Providing and fixing P.V.C. Rain water pipes of 110 mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S.13592-1992 including proper rain water receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wood encleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec.No. As directed by Engineer in charge. |
| 16 | Providing and fixing P.V.C. Rain water pipes of 150 mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S.13592-1992 including proper rain water receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wood encleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec.No. As directed by Engineer in charge. |
| 17 | Transportation of material obtained from debris of various sorts including necessary excavation / loosing including loadting unloading and conveying and disposing as directed.For 5 Km. Spec.No. As directed by Engineer in charge. |