| Sl. No. | Item Description |
| 1 | Excaution in trenches n exc 1.5m wide and n exc 1.5m depth, for foundation, etc. or for shafts, wells, cessipts, manholes, etc. n exc 10 Sqm on plan and n ecx 1.5 m in depth and getting out soft/losse soil. |
| 2 | M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation, filling and mass concrete. |
| 3 | M&L Pre-cast cement concrete block masonryType B1 1:2:4 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar, complete set in CM 1:6 |
| 4 | M & L brick work with sub class \"B\" bricks straight or curved on plan to anyradius built in CM 1 : 4 in half brick thick walls. |
| 5 | M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified |
| 6 | Description same as per item above but, 5 mm dia and over and incl 10mm dia in stirrups, spacers and binders |
| 7 | M&L for Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and includeing mild steel wire (annealed) not less then 0.9mm dia or securing with clips as specified |
| 8 | Form work to sides of concrete foundations ,footings , bases of columns ,raft and raft beams , sides and soffits ( if any)of foundation and plinth beams and similar vertical or to a batter flat rough finished surface |
| 9 | Form work to sides of pillars , posts , struts , piers , columns and stantions rough finished surface square , rectangular or polygonal |
| 10 | M&L form work to sides and soffits of roof beams, lintels lever shelves incl supports over hang etc fair finished surfaces of concrete flat all as specified |
| 11 | M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified |
| 12 | M&L form work to edges of concrete flates ,treads break in floors ,window cills ,concrete railings , openings in concrete walls, floor and roofs n exc 20 cm wide and sisides of RCC/PCC bands in walls, horizontal or sloping and ssimilar work exc 10 cm but |
| 13 | M/L for RCC M30 (Design mix) in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns,etc.; basement slabs,under-reamed piles and mass concrete |
| 14 | M/L for RCC M30 (Design mix) in columns, pillars, plers.posts and struts |
| 15 | M/L for RCC M30 (Design mix) in beams, cantilevers, bressurnmers lintels over 1.5m span |
| 16 | M/L for RCC M30 (Design mix) in Chajjas, complete all as specified |
| 17 | M/L for RCC M30 (Design mix) Slabs supported on walls,beams and columns in floors, roofs,landings, balconies, canopies, deck slabs and inshelves and the like |
| 18 | M&L hard core of gauge exc 63mm but not exc 100 mm depoted ,spread and levelled in layers not exc 15 cm thick watered and rammed to a true surfacebroken stone or boulders |
| 19 | M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base |
| 20 | M&L for Sand filling under floors or in foundations including watering and consolidation |
| 21 | Removing excavated materialn exc 50mand depoting where directed at a level n exc 1.5m above the starting point. |
| 22 | Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm |
| 23 | M&L for randering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement. |
| 24 | M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades (Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified |
| 25 | M&L for 5mm thick rendering on concrete surface of ceiling in CM 1:3and rendering is to be finished even and smooth with out using extra cement |
| 26 | M & L three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces. |
| 27 | M & L two coats of oil bound distemper on newly plastered wall surfaces including preparation of surfaces. |
| 28 | M&L for Non-skid ceramiccoloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm(300x300x8mm),over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade as specified and as directed. |
| 29 | M&L for glazed ceramic coloured tiles in vertical surfaces of size 450X300X7 mm thick set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as dado/skirting and facea of side bldg over & including 10mm thick rendering in CM(1:4) complete all as specified and as directed. |
| 30 | M&L for Non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm (300X300X7mm) in skirting, over 10mm thick screed bed in CM 1:4 on walls set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. |
| 31 | M&L for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade |
| 32 | S&F as in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 630 x 450 mm white with integral foot rests with flush pipe of 32mm dia including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete all as specified and directed by EIC/GE. |
| 33 | S&F vitreous coloured China Europeon water closet (Pedestal Pattern)including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete. |
| 34 | S&F for Health faucet cast copper alloy with push button flexible steel pipe with PVC lining of 1 Mtr long suitable for 15mm pipe, Make- Fortune/Equivalent. |
| 35 | S&F for plastic water closet seat cover, black or white closed pattern with flat bottom and cover and mild steel chromium plated hinging device. |
| 36 | S&F vitreous china urinal half stall type (back or corner wall type ), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with discharge pipe etc complete all as specified and as directed by Engineer In Charge. |
| 37 | S&F Anodised aluminium window and ventiltor shutters, fixed/sliding type without sash bar, aluminium section weighin0.55 kg/m including necessary joining cleat glazing clips, rubberpacking, anodised aluminium snap beading screw etc. complete all as specified including powder coating of minimum 50 micron thickness |
| 38 | S&F 100mm dia stack clamps out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to ball or roof |
| 39 | S&F for 100mm dia grating doom with waste hole of PTMT (Minimum weight 25 gms) |
| 40 | S&F for Swivel shower rose of CP any colour for fixing with 15mm pipe (Minimum weight 40 gms) |
| 41 | S&F vitreous china wash basin white, flat, back, size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipe all as specified |
| 42 | Supply only 32mm dia waste coupling of PTMT(half or full thread) min wt 40gms |
| 43 | S & F pillar taps cast alloywith capasten head screwed down high pressure with without lettered \"Hot\" or Cold with long screwed shanks and fly-nuts screwed for iron pipe and fixed |
| 44 | S&F 600mmx450mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer |
| 45 | S & F bib taps 15mm bore cast copper alloywith crutch or butterfly, handle, screwed down, screwed for iron pipe. |
| 46 | S & F angel valve15mm bore cast copper alloywith screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete. |
| 47 | S&F PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified. |
| 48 | S&F tubular towel rail brass chromium plated, 20mm dia, D type 60 cm long between flanges. |
| 49 | S&F for 75 mm bore PVC (SWR) pipes ofsingle socketed in any length with rubber ring joints laid in trenches or in floors all as specified |
| 50 | S&F for 75 mm bore PVC (SWR) pipes ofsingle socketed in any length with rubber ring joints fixed to wall all as specified |
| 51 | S&F 75 mm bore. PVC (SWR) bends |
| 52 | S&F for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches |
| 53 | S&F for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall |
| 54 | S&F 110mm bore PVC (SWR) bends with oval access door all as specified |
| 55 | S&F 110 mm PVC (SWR) bend any radius |
| 56 | S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door |
| 57 | M&L PVC (SWR) floor trap diameter of outlet 75 mm, plain with grating including jointing with solvent cement |
| 58 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) |
| 59 | S & F for angle valve15mm bore cast copper alloy fancy type chromonium plated with long shank and cup(concealed type)screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions. |
| 60 | M& L Chequered cement concrete tiles 25cm x 25cm x 20mm thickset, jointed and pointed in neat cementsluny in floors over 20mm thick screed beb in Cm 1:6 complete all as spercified |
| 61 | Supply only integral water proofing compound |
| 62 | M&L Water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a) M & L screed bed and bedding layer of Mortar 10mm thickin CM 1: 4 for roof slabmixed with water proofing compound (to be measured and paid separately) as per manufactures instruction finished even and plain complete(b) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight)(c)Preparing & cleaning of fully dried cement concrete surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384.(e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric(weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.(f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm. |
| 63 | M & L screed bed and bedding layer of Mortar 20mm thickin CM 1: 4 for roof slabmixed with water proofing compound while the concrete is in green condition (water proofing compound to be measured and paid separately) as per manufactures instruction finished even and plain complete |
| 64 | M & L 15mm thick rendering on fair faces of brick work or concrete surface in CM 1 : 4to be finished even and smooth with out suing extra cement using 2%WPC as per manufacturing instruction. |
| 65 | Supply only Integral water proofing compound |
| 66 | M & L plain cement concrete 1:3:6 type C-2 (using 40 mm graded broken stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore NP3 drain pipe as specified and as directed. |
| 67 | M & L salt glazed stone ware drain pipes 150 mm bore, grade \"A\" laid in trenches, jointed and tested complete all as specified and directed. |
| 68 | M & L plain cement concrete 1:3:6 type C-2 (using 40 mm graded broken stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete for 200 mm bore NP3 drain pipe as specified and as directed. |
| 69 | M & L salt glazed stone ware drain pipes 200 mm bore, grade \"A\" laid in trenches, jointed and tested complete all as specified and directed. |
| 70 | M&L for providing cement concrete Type B1 1:2:4 (20mm graded aggregate) as in lintel upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses parapet and railings up to 60cm in height, copings, bed plates as directed. |
| 71 | M & L precast reinforced cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in cover slab of manholes, septic tank etc, set in cement mortar (1:4) including necessary form, moulds etc and including taking out/removal of existing unserviceable cover slab from manholes /septic tank complete all as specified and directed.(Note: Reinforcement shall be measuredand paid separately) |
| 72 | S&F rotational moulded polyethylene water storage tank consisting of three laver cylindrical vertical with top closed hoisted and fixed in position all as specified and directed capacity 1000 ltrs. |
| 73 | S&F25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe |
| 74 | S&F 25 mm dia Ball valves ,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule |
| 75 | Supplying and laying 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls complete all as specified |
| 76 | Supplying and laying 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls complete all as specified |
| 77 | Cutting chase, pinning in making good to faceing where required and pointing in cement mortar 1:3 to ends or edges of landing, and cutting chase for concealed water tubing or concealed conduit wiring etc and making goodcutting exc 10cm but n exc 20cm. |
| 78 | S & F solid PVC door frames of sizes 50mm x 47mm made out of 5mm but single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheetreinforced with MS Square tube complete all as specified and as directed. |
| 79 | S & F factory made solid panel PVCdoor shutter 28 to 30mm thick (styles), with 2,4, or 6 raised panel design with 2mm thick moulded PVC sheet on the frant face and 2mm plain coor PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing |
| 80 | S&F, 100 mm long butt hinges, extruded alminium alloy with galavanised mild steel hinge pin, anodised and fixed , type C-21 |
| 81 | S&F, 200 mm long aluminium anodised barrelbarrel tower bolts of extruded section and fixed as specified and as directed. |
| 82 | S&F, 125 mmaluminium handles cast type, anodised complete all as specified and as directed. |
| 83 | M&L 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate laid in panels surface finish evenand smooth without using extra cement as in plinth protection complete all as specified and as directed. |
| 84 | Surface dressing n exc 15 cm deep in soft/loose soil |
| 85 | S&F, 200mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 86 | M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in surface channels, man-holes and drains |
| 87 | M&L for PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in surface channels, and drains |
| 88 | M&L for Loose filling with broken bricks of gauge 40 to 80 mm in soakage pits, soakage well |
| 89 | M&L, 25mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite |
| 90 | M&L for ATT for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) |
| 91 | M&L for ATT for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface |
| 92 | M&L for ATT for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area |
| 93 | M&L for ATT forTreating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall |
| 94 | M & L forpoint wiring with PVCinsulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, including Modular cover plate of suitable size etc with necessary fixing accessories andearth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screws complete including taking down old u/s wiring/ fittings etc all as specified for one light / fan / bellpoint controlled by one switch. Note : 1.Two runs ofcable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.Make of conduit :- Sudhakar/ Precision/ Diamond,Make of wire :- Finolex/ Havells/ Polycab/ KEI |
| 95 | -Ditto- all as per item No 94.00 above but for one 6A 2pin/3pin socket out let multipurpose on the same board with other switches. |
| 96 | All as per item No. 94.00 above but wiring complete with 2.5Sqmm for 3 pin 16A socket multipurpose on independent board |
| 97 | S & F modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed. |
| 98 | S & F modular type 2/3 pin 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.Make : Anchor (Panasonic)/Legrand/ Havells (Crabtree) |
| 99 | S & F modular type 2/3 pin 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed. Make : Anchor (Panasonic)/Legrand/ Havells (Crabtree) |
| 100 | S & F modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. Make : Anchor (Panasonic)/Legrand/ Havells (Crabtree) |
| 101 | S & F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed.Make : Anchor (Panasonic)/Legrand/ Havells (Crabtree) |
| 102 | S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed |
| 103 | S & F Modularcover plate 8 modules complete all as specified and directed. |
| 104 | S & F Modularcover plate 6 modules complete all as specified and directed. |
| 105 | S & F Modularcover plate 3 modules complete all as specified and directed. |
| 106 | S & F Modularcover plate 2 modules complete all as specified and directed. |
| 107 | S&F Surface, hanging and wall mounted aluminium batten (Double side connection) suitablefor LED tube 18 watts, 230 volts alongwith tube rod 20/22 watt (double side connection),including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directedMake: Jaquar/ Bajaj/ Wipro |
| 108 | S & F 10 W capacity surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, CCT 4000K to 6000K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, CRI> 80, lamp burning hours not less than 50000, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor PVC insulated cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make : BAJAJ/JAQUAR/WIPRO |
| 109 | S & F Fency Jumbo Batten holder metal ring suitable for LED bulb of 9 Watt complete all as specified and directed. Make - Havells/ Anchor |
| 110 | S & F LED Light Bulb 9 watt, Pin type of white colour, 230 V complete all as specified and directed. Make - Bajaj/ Orient/ Philips |
| 111 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. Make :- ALMONARD / ORIENT |
| 112 | S&F modular type 3/5 pin socket with one single pole MCB 20 Amp 230 Volts complete all as specified including concealing in wall suitable for Geyser, AC and Domestic appliances complete all as specified and directed. Make - Havells/ Legrand/ Schneider |
| 113 | S & F MCB DB, 4 way, SPN, double door, 240 Voltsand including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed.Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.Make: Schnieder/ Legrand/ IndoAsian |
| 114 | S & F MCB SPN 40 Amps, 240 / 415 Volts, \"B\" Series, 50 Hz, 10 KA Breaking capacity complete all as specified and directed.Make: Schnieder/ Legrand/ L&T |
| 115 | S & F MCB SP 5 to 32 Amps, 240 / 415 Volts, \"B\" Series, 50 Hz, 10 KA Breaking capacity complete all as specified and directed.Make: Schnieder/ Legrand/ L&T |
| 116 | M&L for sub mainwiring with twosingle core2.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 2.5 Sqmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. |
| 117 | M&L for sub mainwiring with twosingle core1.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 1.5 Sqmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directedNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. |
| 118 | Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core including necessary connection and providing cable lugs as required all as specified. Make: GRANDLEY / POLYCAB / KEI |
| 119 | M&L for cutting existing road/hard and dence soil not exc 45 x 60 cm in wide & depth getting out excaveted materials for laying GI tube; returning filling & well rammin watering finish surface 10 cm from top using PCC 1:3:6 not less than 4 inch thick; including removal of surplas soil all as per directed. |
| 120 | S&F of HDPE pipe 100 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etc complete all as specified and directed. Make: PLASTO / PRECISION / SUPREME / SUDHAKAR / DUPLON / TIRUPATI / FINOLEX |
| 121 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 122 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. Make : MEHTAB TILES / NATIONAL |
| 123 | S&F in repair/replacement of building Security lightfitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. |
| 124 | M&L for earthing using galvanised earth lead wire 4.0mm dia complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deepbelow ground level connection to and including galvanised earth lead wire 4.0mm dia to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.Note: (1). 7.5 RM GI wire in deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately (2) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI earth plate. |
| 125 | Supply, laying, fixing, or passing through pipe XLPE/PVC insulated, armoured heavy-duty electric cable with aluminium conductor of 1100 Volts grade, 16 Sqmm, 4 core, including necessary terminations with suitable size cable lugs, glands, and proper connections, complete all as specified and directed.Note: The cable shall be clamped on wall with suitable clamps at regular intervals.Make: Polycab / KEI / Anchor (Panasonic) / Gloster. |
| 126 | M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85* C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm NB UPVC medium grade surface/recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS:732- 1989, including making good of disturbed surfaces of wall/celling/floor, all complete as specified and directed. Make: Polycab / KEI / Anchor (Panasonic) / Gloster.NOTE: One run of phase conductor, One run of neutral conductor, One run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length2 X 6.0 mm2 + 1 X 4.0 mm2 earth wire |
| 127 | Supply, installation, testing and commissioning of 4 Way Vertical TPN (VTPN) Double Door Distribution Board, sheet steel enclosure, dust and vermin proof, IP-43 protection, with copper bus bars rated 200A, neutral link, earth bar and provision for incomer MCCB/Isolator and outgoing MCBs/ MCCBs as required, suitable for 415V, 3 phase, 4 wire, 50Hz AC supply, including necessary accessories, earthing connections, painting, interconnections, and making good the disturbed surface complete as per specification and as directed by Engineer-in-Charge.Make: L&T / Schneider / Siemens / ABB / Legrand / Havells. |
| 128 | S & F of MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall,making good the disturbad surfaces and making all connections,complete all as specified and directed Make :- LEGRAND/ L&T/ ANCHOR (PANASONIC)/ SCHNEIDER/ INDO ASIAN |
| 129 | S & F of MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity\"C\" series complete.Make :- LEGRAND/ SCHEINDER/ L&T |
| 130 | S & F of MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity\"C\" series complete.Make :- LEGRAND/ SCHEINDER/ L&T |
| 131 | Supply, installation, testing and commissioning of industrial plug, heavy-duty type, rated 32A, 200–250 Volts, 2P+E configuration, conforming to IS/IEC 60309-1 & 2, constructed from high-impact, flame-retardant thermoplastic material with IP67 degree of protection against dust and water ingress, complete with corrosion-resistant pins, secure locking arrangement, colour-coded voltage indicators, and suitable for industrial/commercial indoor and outdoor applications. The scope includes provision of all necessary accessories, wiring terminations and testing to ensure safe and reliable operation, all as specified and directed by Engineer-in-Charge.Make: Legrand / Schneider / L&T / Siemens / ABB. |
| 132 | Supply, installation, testing and commissioning of modular Surge Protection Device (SPD), 3-Pole +N, suitable for 230/415V, 50Hz AC system, conforming to IEC/IS 61643-11, with maximum discharge current (Imax) 50kA, complete with proper connection, as per manufacturer’s recommendations, and earthing, including testing and commissioning complete as specified and directed by Engineer-in-Charge.Make: Schneider Electric, Legrand, ABB, Havells, Siemens |
| 133 | Supply, installation, test, and commissioing of online UPS for 30 min backup three phase AC input and three phase out put 3x400V AC (3Ph+N), microprocessor controlled generator compatible, auto by pass and emergency power off, pure sign wave with following specifications of capacity 60KVA Complete all as specified and directed by Engineer-in-charge. Make :Siemens / V Guard / Microtech / Labotech / Sukam / Tata Liebert / APLAB / Luminous / Protect Services / Sinetrac / Power One (A) INPUT : (i) Voltage- 400V AC / 415 VAC (3Ph + N) (ii) Voltage Range 320VAC ~ 460VAC (Ph-Ph)(iii) Frequency Range 50± 6%(iv) Input power factor : 0.99 or batter at rated load (v) Input current harmonic distortion (THDi) < 3% on full load |
| 134 | (B) OUTPUT : (i) Voltage 380VAC /400VAC / 415VAC(± 1%) (3Ph + N) (ii) Voltage Regulation ± 1% ( battery Mode) (iii) Frequency & Waveform 50 Hz ± 0.5% Pure Sine Wave(iv) Harmonic distortion less than or equal to 3% THD ( linear load)(v) Harmonic distortion less than or equal to 5% THD ( non linear load)(vi) Efficiency not less than 93% (vii) Overload Capability 110% for 10 min or better, 125% for 05 min or better, 150% for 30 Sec or better (viii) Protection- Over voltage, Under voltage, Short Circuit, Over temperature, Overload(ix) Transient Response-±5% (Dynamic Regulation for 10% to 90% step linear load)(x) Transient Recovery < 1 cycle (Steady state condition after 10% to 90% step linear load) (xi) Crest Factor - 3:1 (Max)(C) Battery : (i) Battery Type VRLA / SMF / Tubular / NICAD / Lithium ion(ii) Battery Numbers 12V x 32 Nos (29 ~ 32 Nos adjustable) (iii) Movable trolley for Batteries - with trolley |
| 135 | (D) STATIC BYPASS : (i) Manual & static bypass- required(ii)Transfer Time Zero (iii) Maintenance Bypass required(iv) Eco Mode required (E) STANDARDS: (i) Safety : IEC/EN 62040-1 (ii) EMC/EMI/RFI : EMC 62040-2 (iii) Performance : IEC 62040-3 (iv) Quality Standards ISO 9001,ISO 14001,ISO 18001 |
| 136 | (F) COMMUNICATIONS: (i) Network Management RS232, RS 485 MODBUS, SNMP (G) CONTROL PANEL : (i) LCD Panel :To monitor Input (Voltage, Current & Frequency), Output (Voltage,Current & Frequency) as well as DC (battery Level & Voltage),Load in KVA /KW %tage(ii) Indication :Mains & Inverter on, Load and Battery Level, UPS Trip(iii) Audible Alarm : Main Failure, Inverter Overload, Battery Low, Fault / Short circuit(iv) Switches : Mains and Battery ON/OFF MCCB. (H) ENVIRONMENTAL PARAMETER : (i) Ingress protection IP20(ii) Operating Temperature 0- 40 °C (iii) Humidity 0- 95% (Non Condensing) (iv) Altitude 0-1500 M at 100% Load without derating |
| 137 | Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area50 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Make: GRANDLEY / POLYCAB / KEI / FINOLEX / HAVELLS / RR KABLE |
| 138 | S & F in repair MCCB 63 Amps, 36 KA Four Pole, MCCB with Thermal Magnetic Protection Unit 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed with following specifications. Make: Legrand, Schneider, ABB, Siemens (i) Range: 16A-100A, Ics=100%Icu, Four Optimum Frames(ii) Thermal Adjustable – 0.8 to 1In(iii) Magnetic adjustable - 5 to 10ln (iv) Breaking Capacity – 36kA(v) Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A(vi) Adjustable tripping: 0 - 0.3 - 1 - 3s(vii) Suitable for Isolation |
| 139 | S & F in repair MCCB 40 Amps, 36 KA Three Pole, MCCB with Thermal Magnetic Protection Unit 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed with following specifications. Make: Legrand, Schneider, ABB, Siemens (i) Range: 16A-100A, Ics=100%Icu, Four Optimum Frames(ii) Thermal Adjustable – 0.8 to 1In(iii) Magnetic adjustable - 5 to 10ln (iv) Breaking Capacity – 36kA(v) Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A(vi) Adjustable tripping: 0 - 0.3 - 1 - 3s(vii) Suitable for Isolation |
| 140 | Supply, installation, testing and commissioning of Tower Type Air Conditioner, Floor Standing, capacity 3.0 TR, high-performance unit suitable for large open areas such as lobbies, conference halls and commercial spaces, complete with indoor and outdoor units. The system shall be equipped with rotary/scroll compressor, eco-friendly refrigerant R410A/R32, high airflow rate for quick temperature control, operating on 220–240V single-phase or 380–415V three-phase supply (as applicable). The AC shall provide multiple modes of operation (Cool/Dry/Fan/Sleep), low-noise performance, digital display with remote control and programmable timer, including all standard accessories, copper piping, interconnecting cables, mounting hardware and civil/electrical works required for proper installation. The unit shall be supplied with minimum 1-year comprehensive warranty and 5-year compressor warranty, complete all as specified and directed by Engineer-in-Charge.Make: Daikin / Blue Star / Voltas / Carrier |
| 141 | M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long(100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications completeall as directed by Engineer-in-Charge.(a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns .Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm,External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms,Recommended for normal soil conditions. Conforms to IS : 3043 – 1987.(c)Installation of earthing with bore well machine complete for bore exceeding upto 4.5 meter below ground level complete all as specified and directed by Engr-in-Charge. |
| 142 | Supply & Fix copper stripof size 20 X 3 mm duly covered,fixed on porcelain insulators along the wall / roof / ceiling etc complete all as directed.Note : (i)Cost of Porcelain insulators and screw shall be of non-corrosive type and cost is deemed to be included in the quoted rate of the job. (ii) Gap for fixing of support insulator shall not be more than 35cm from one onother. |
| 143 | Note : A SUM OF RS 0.00 TOWARDS SCHEDULE OF CREDIT SHALL BE DEDUCTED TO ARRIVE THE CONTRACT SUM |