| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 3 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 4 | M & L for sand cushioning by spreading in trenches fine crush sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 5 | Supply and laying in repairs un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Make: MEHTAB /NATIONAL TILES |
| 6 | Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Note :- Serviceable cable cover obtained here-in-after shall be reused. |
| 7 | Dismantling only in repairs of PCC foundation / pole coping from ground level all as per specified. |
| 8 | M & L in repairs for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed. |
| 9 | Supply and Laying in repairs or fixing or passing through pipe, XLPE insulated ISI marked, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required includingdisconnection/taking down of existing cable all as specified. Make: Polycab/ Havell\"s/ KEI/ Gloster |
| 10 | -Ditto- all as per item No 9 above but 10 Sqmm 4 Core complete all as specified & directed. Make: Polycab/ Havell\"s/ KEI/ Gloster/ Universal |
| 11 | M & L for earthing in repairs complete with Copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materils |
| 12 | S & F in repairs copper 20x3 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in conuit / pipe or fixed to poles or any other indicated situation for earthing, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge |
| 13 | M & L in repairs for reinforced cement concretenominal mix M-20(using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed.(Note - Reinforcement and form work will be measured and paid separately). |
| 14 | M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 12 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed. |
| 15 | M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 8mm dia bars as in binders, spacers, strippusincluding cutting to length, bent to shape required, cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed. |
| 16 | M & L in repairs for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed. |
| 17 | Dismantling only in repairs of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed. |
| 18 | Supply, Fixing in reparis / replacement and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make: Bajaj |
| 19 | Preparingsurfaces in repairs of steel tubular swaged pole LT with scraping out old paint by emmery paper, wire brush complete and painting with two coats of aluminium paint and numbering of poles with white paint on black paint background and stripping with black and yellow synthetic enamel paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market |
| 20 | M & L in repairs for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black synthetic enamel paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height all as directed by Engineer in Charge. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market |
| 21 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel |
| 22 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 130 x 180 x 77mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - National/ Sintex/ Hensel |
| 23 | Supply & Fixing LT, Air Circuit Breaker, operational voltage 660 Volts, insulation voltage 1000 Volts, AC, 50 cycles, 3 phase, 4 pole, Manual draw out type, rated current rating 630 amps and of breaking capacity 50 KA with quick make, quick break with manual operating mechanism complete with Triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating \"Trip Healthy Circuit\" ancillary switch etc complete over load release 400 to 600 Amps complete all as specified and directed. Make - Legrand/ L&T/ Schneider/ABB/C&S/Siemens |
| 24 | M&L for cutting existing road/hard standing not exc 30x60 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well rammaing wateringfinish suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top\", including removal of surplase soil all as directed. |
| 25 | S & F in repairs/ replacement of GI steel tubing medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cable protectionincluding necessary fittings , clamps for supports, etc all as directed by Engineer in charge. Make- TATA/ JINDAL/ ZENITH/ SURYA |
| 26 | M&L for taking down old unsv and supply & lay 3Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit with necessary saddle, clamps, bolts & nuts,all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / KEI / HAVELLS/ BENLO |
| 27 | Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and remove the carbon after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LEDwill be measured and paid separately on respectiveitemof Sch \"A\"here-in-after]. |
| 28 | Supply and fix in repairs flood lightluminaire with polycarbonate optics pressure die cast housing IP 66 ingress protection, 4 KV in-built and 10 KV external SPD, having efficiency not less than or equal to 150 lm/watt, CCT 5700oKin buildings etc the fitting shall be of LED type 150 Wattscomplete all as specified. Make : Bajaj/ Jaguar/ Wipro/ Benlo/ Havells/ Crompton |
| 29 | S&F in repair of building Security lightfitting made up of pressure die cast alluminium body with mid power 60 Watt LEDluminaire, with IP 66 protection, 4 KV in-built and 10 KV external largeprotection having luminuous efficiencies not less than 110 lm/watt CCT 5700K as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make : Bajaj/ Wipro / Havells /Jaguar /Benlo |
| 30 | Dismantling complete old Bolard light fitting and Supply & Fix 8/9 watts LED Bollard Garden light fittings with efficient high outputLED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation0.3 Meter x 0.3 Meter x 0.3 Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry complete. Make:- Havells / Bajaj/ Crompton/ Jaguar/ Benlo/ Wipro |
| 31 | Supply and fixing Post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including removing old unsv lights complete. Make:- Bajaj/ Havells / Benlo/ Crompton/ Jaguar/ Wipro |
| 32 | Supply and fixing Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. Make:- Havell\"s/ Crompton/ Jaguar/ wipro/ Bajaj/ Benlo |
| 33 | S & F in repair/replacement of LED Driver 60 to 70 Watts Suitable for street light fitting operating on 230 Volts, 50 Hz, AC Supply complete all as specified and directed. Make:Crompton /Havells/Bajaj |
| 34 | S & F in repair/replacement of LED Driver 30 to 40 Watts Suitable for street light fitting operating on 230 Volts, 50 Hz, AC Supply complete all as specified and directed. Make:Crompton /Havells/Bajaj |
| 35 | M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 25 to 50 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M |
| 36 | M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 120 to 185 Sqmm complete with testing till satisfaction of Engr-in-Charge. Make:- Denson/ Raychem/ Birla/ 3M |
| 37 | S & F in repair Analog Time switch astronomical type FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY). Make L&T/ C&S |
| 38 | S & F in repair 3 Pole power contactor MNX-18 of coil voltage 415 VoltsMake - L&T/ C&S |
| 39 | S & F in repair spare coil for MNX-18 3 pole power contactor of 415 voltsMake - L&T/ C&S |
| 40 | Taking down and Refixing of Alluminium roof conductor/ down conductor including Air termination rod including provision of new insulator (procelain type) support, GI screw and all connected item complete all as specified and directed.Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter.ii) The raete is deemed to be inclusive for providing Procealin insulator, Galvanised screws, Plugsiii) PCC Block required shall be measure and paid under respective items |
| 41 | S & F in repairs aluminium earth strip as roof/down/earth ontunity conductors of size 25x3mm with saddles, insulators, screws, etc to / at any position / locationofsheds/ buildings of height up to 30 meter complete all as specified and directed by the Engineer-in-charge Note -i)The quoted rate is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter.ii) The rate is deemed to be inclusive of Procealin insulator, GI screws, Plugsiii) Space of insulator support shall not be more than 30 cm on roof / wall and 70 cm if insulator is placed over PCC block. |
| 42 | S & F in repairs air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary terminal base plate of not less than 3 mm, scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge |
| 43 | M & L in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw in replacement of the unserviceable. Including MS box made out of 3 mm thick shheet for fixing the block |
| 44 | M & L for pre-cast cement concreate block of size 0.15M x0.15M x0.15M for fixing of Aluminium striptype C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the coccrete block on terrace of bldgs of height up to 30 meter all as directed at site Note -i)The quoted rae is deemed to inclusive of T & P/scaffolding/staging etcfor executing the work in buildings of height up to 30meter. |
| 45 | Supply & fix in repairs of defective worn out GI funnel of 15 mm dia size suitable for GI/ Copper earthing pits complete all as specified and directed. |
| 46 | Supply only Industrial type commercial salt suitable for renewal of GI/ Copper earth plate complete all as specified and directed. |
| 47 | Supply only Industrial type Charcoal suitable for renewal of GI/ Copper earth plate complete all as specified and directed. |
| 48 | M & L in repairs/ replacement of broken old us PCC earth chamber alongwith PCC cover of size 600 x 600 mm complete all as specified and directed. |
| 49 | M & L for earthing in repairs complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification. |
| 50 | M & L for depute service representativeto attend the LED Solar Light fittings of 18wattage once in a month . Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd for 26 fittings Every Fortnightlya) Solar PV Modules - Check the Circuit Voltageand current characteristics. Also, check the mechanical integrity of the Solar PV Modules.b) Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. Note:- Electrolyte solution will be measured seprately under this Schedule.c) Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring.d) Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed.e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering ifa any requiredf) Module Cleanliness - Cleaning of the dust accumulatedover the Solar Module, and taking corrective measures |
| 51 | M&L for preparation of old painted surfaces of Solar Street Light Poles including acessoriesby scarping old paint and applying two coats ofpaint including numbering of pole with black synthetic enamel paint all as directed by Engineer in Charge. Make:- Paint:- ASIAN/ NEROLAC/ BERGER, Primer:- Best available ISI Brand in Market |
| 52 | Supply and fix in replacement of LED 18 watt DC solar light fitting Make - Emvee / ICPC Solar or equivalent |
| 53 | Supply and fix inreplacement of low maintenance VRLA lead acidic batteryof 120 AH suitable for 1 x 18 watt Soalr Lightfitting all as per recommanded by Manufracturer |
| 54 | Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required |
| 55 | Supply only electrolyte solution to be incorporated in servicing, suitable for Solarcharged battery of any capacity. |
| 56 | M & L in repairs for servicing ofCentrifugal pump setof capacity 20 HP by opening end covers, greasing the bearings, replacing worn out nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush and painting one coat ofsynthetic enamel paint, including writing/marking in 1\" size letters SM & MES No. for the following capacity of pumps:- |
| 57 | All as per Item No 56.00 above but Pump set 15 HP |
| 58 | All as per Item No 56.00 above but Pump set 5HP |
| 59 | Supply and fix in repairs/replacement of old unserviceable Cast iron tank coverwith MS strip /flat iron framework with all necessary fixing and locking arrangement nuts,bolts all as per BMC standards any required alteration to the tank for fixing ofnew CI covers all as specified and directed by the Engineer -in-Chief ofsizes:- 508mm dia. (weight of tank cover not less than 12 Kgs) |
| 60 | M&L for rewinding of electric motor 20 HP 3 phase 50 Hz 415 volt of following capacities complete all as directed and specified as under: (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc.(b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing onload. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA.(e) Replacement of winding terminal plate with brass stus,/ nut, bolt washer. |
| 61 | All as per Item No 60.00 above For Motor 15 HP Cap |
| 62 | S&F in repairs the following component in existing LT Kiosks (Idoor/Outdoor) including disconnecting and taking down at different locations all as directed :-Voltmeter Digital type ,0-500 Volts of size 96x96mm. |
| 63 | All as per item No 62 above but Ammeter Digital type of upto 400 amps capacity of size96X96mm. |
| 64 | M&L in repairs selector switch for voltmeter / Ammeter complete. |
| 65 | M&L in repairs Phase indicating lamp neon type complete with holder assy RYB phase complete. |
| 66 | M&L for supplying,hoisting and fixing rotational moulded polythylene water storage tanks (cylinderical vertical with closed top) as per IS12701-1996 (refirmed 2006) 0f under mentioned capacity with virgin food grade plastic,UV stabilised tank and lid,two layers protection with black outer layer for superior UV protection and white inner layer to see water level and tank condition including covers,hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out,Inlet and outlet pipes etc complete all as specified and as directed following capacity:-Capacity of 2000 Ltrs |
| 67 | capacity of 1000 Ltrs |
| 68 | Capacity of 500 Ltrs |
| 69 | S&F in repair of Transciever automation for the water level Detector and controller with the feature mentioned here under comprising of following:(a) S& F Transciever must communicate at a distance of 3km -5kms range with each module must have the LORA/GSM or suitable communication module ( long range antenna) must work above 500 mhz and each module shall have a processor module connecting to the sensor,with the facility that the processor module to sense the low level (10-20%) and high level of the water level (90-100%) so as to raise the hooter and communicate with the other hardware modules with antennas (b) S&F transducer module wiring through the D sub connectors (MIL industrial grade are to be used). All the wiring must be shielded optical co-axial cable for connection to flasher and hooter. Rates quoted are deemed to be included for suitable flasher and hooter. (c) S&F Hooter 12V/5 Amp with suitable converter or hooter suitable for 230V AC Supply must be provided standard suspended rust proof stand Note: All the NPT cable glands must be used for the sensor interface and MCB controller board.(d) S&F 12V flasher with suitable converter or flasher suitable for 230V AC Supply connected with suitable 3 Core Co axial cable suitably crimped nicomatic connector. Note: All the cables to be drawn through suitable medium grade conduit suirtably fixed with clamps. (e) S &F of LED display board with superior night vision display to be provided at the receiver station. (f) S&F controller Board confirming to IP 65 protection 3D printed with EMI/EMC compatible FE 32 material for the enclosure. Note: (a) One transmitter for over Head Tank and one receiver for Pump House .(b) Contractor has to visit the site before execution. Any cable required deemed to be included in quoted rate. No extra payment will be made on this account. |
| 70 | Supply ,Laying, fixing, connecting and testing in repairs Cast iron pipes with spigot and socket ends centrifugally cast.Class B, in any length laid intrenches, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc including taking out old u/s steel water tubing for the 100 mm bore complete all as specified and as directed , ISI marked. Make: kesoram,IISCO |
| 71 | Ditto all as per item No 11 above but 80 mm dia bore complete |
| 72 | Supply & fixing in repairs of joining CI/DI fittings for Spigot/Socket pipes such as bends of any radius and angle,collars,tapers,tail,pieces,tee pieces,caps and plugs suitable above from 20mm bore diato 100 mm all socket and spigot or side flanged including taking out old u/s CI/DI fittings complete all as specified and directed. |
| 73 | Supply and replace in repairs aviation light LED based operations on 230V,50Hz AC one medium intensity red obstruction light for fixing on top of overhead water storage tank,red steady or flashing 2000cd+25% at least three low intensity single onstruction lights on the middle of storage tank comprising ICAO Annex 14 volume I 2018 Chapter 6 and FAA 70/7460-1L,Red obstruction lighting for water storage tanks |
| 74 | M&L for sub mainwiringconcealed with twosingle core1.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC conduitwith and includingPVC insulated 1.5 Sqmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dollyincluding taking down old unserviceable submain wiring complete all as specified and as directed Make:Havells/Finolex/Benlo/Anchor panasonicNote : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. |
| 75 | M&L in repairs CT coils any capacity suitable for 1100volts, 50Hz, AC, supply complete. |
| 76 | Drilling and taping cast iron water mains (in position) for branch connections 15 mm bore of the internal dia. |
| 77 | S&F in repairs gunmetal gate or globe valve for 50 mm diameter, conforming to IS-778, Class 2, ISI marked, Copper alloy body, Test pressure (Hydrostatic) for shell 2.4 Mpa and Seat & back seat pressure of about 1.6 Mpa with maximum working temperature of about 45 °C with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed.Make :-Leader / Zoloto / Shakti |
| 78 | -Ditto- all as per Item No 77.00 above but of size 40 mm dia |
| 79 | -Ditto- all as per Item No 77.00 above but of size 25 mm dia |
| 80 | M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting (if required) from any position / location as listed hereinunder and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete al as specified and as directed by the Engineer-In-Charge. Make:- ASIAN/BERGER/APCOLITE Note: each job consist a LT Panel or Electric Motor/Sluice Valve/AMF panel etc |
| 81 | M&L for dismantling existing unserviceable sluice valve and supply and fix new sluice valve ISI marked IS-14846 PN 1.6 with iron operating wheel, flanged type rubber gasket, nut, bolts, washers, including any addition alteration. Fixing of new sluice valve of size 100 mm bore complete. |
| 82 | All as per item No 81.00 above but of 80 mm bore complete. |
| 83 | M & L for valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including dosmantling the existing valve chambercomplete all as specified and directed by EIC. |
| 84 | M&L for collection andtesting of Water sample from source and User ends and test it in certified lab and submit result to the department.Note: One job of sample collection and testing consist of 1 sample of source water and 1 from user end |
| 85 | Supply, lay/fix, connect and testing steel water tubing, 25 MM medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to wall/ceiling or laid in trenches/floors including taking up/down existy tubinging and connections complete all as specified and directed by the Engineer-in-Charge. |
| 86 | All as per item No 85.00 above but of 40 mm bore. |
| 87 | All as per item No 85.00 above but of 50 mm bore. |
| 88 | All as per item No 85.00 above but of 80mm bore. |
| 89 | All as per item No 85.00 above but of 100mm bore. |
| 90 | M & L for laying of LT XLPEinsulated, armoured heavy duty 1100 volt grade electric cable with aluminium conductorof size 2 Core 10 Sqmm in wall/Roof/steel Structures of buildings/Storgae Sheds etc complete all as specified and directed by Enginner incharge includingof cable glands, lugs & making all connections complete as required at site and as directed by Engr-in-Charge. Make - KEI/ Polycab/ Gloster/ Havells |
| 91 | M & L for laying of LT XLPEinsulated, armoured heavy duty 1100 volt grade electric cable with aluminium conductorof size 2 Core 6 Sqmm in wall/Roof/steel Structures of buildings/Storgae Sheds etc complete all as specified and directed by Enginner incharge includingof cable glands, lugs & making all connections complete as required at site and as directed by Engr-in-Charge. Make - KEI/ Polycab/ Gloster/ Havells |
| 92 | S&F in repairs electronic timers for star-delta starter three phase 415 volts including taking down old unserviceable starters complete. |
| 93 | M& L for load balancing of a LT Panel job consist of checking the load in three phases in different time period as 9.00 am,2.00 PM and 9.00 PM and distribute load to make load balance as possible |
| 94 | M&L in replacement from PVC to GI metal for fabricating a tank of GI metal sheet of 6mm thickness and to be stored 300 ltrs storage capacity for diesel and fitting inside DG Set room at thane station including pipe fittings for diesel tank. And painting with primer and synthetic enamel paint of 2 coats. |
| 95 | Supply and fix a 1 HP residential water pump self priming regenerative for pumping waterin case of emergency for supply of water in md accn and other places |
| 96 | Supply and fix outdoortype vermin and weatherproof totally inclosed cubical type front operated, sufficient ventilation on sides cubicle type fabricated out of 3.15 mm thick CRCA sheet duly treated with seven tank process and painted epoxy powder coated siemens greycolour and with industrial type built in locking arrangement. The Panel indoor type cubical panel board IP 52 free standing floor mounted(CPRI approved manufacturers).The panel to be prewired with PVC insulated copper conductors appropriate current carrying capacity for connecting the incoming and out going MCCBs and MCBs. including disconnecting the LT panel and taking down the unserviceable cables and including MCBs.. Disconnecting the incoming and out going cable connection and dismantling the unserviceable conventional type industrial meter board and removing from site for further disposal and making LT UG cable connectioncomplete consist of following items:- Location Near OC Residence and Near Offrs Qtrs at Thane |
| 97 | (a)INCOMER (i)MCCB 160 Amps 415V 16 KA 4 pole - 1 No. Make: Havells/Legrand/indoasian(b) OUTGOING(i)MCCB 63 Amps \"C\" Series - 1 No. Make: Havells/Legrand/indoasian(ii)MCCB 63 Amps \"B\" Series - 2 No.Make: Havells/Legrand/indoasian(iii)MCB SPN 40Amps (B Series) - 02 Nos Make: Havells/Legrand/Indoasian (c) Electrolytic copper bus bar 125 Amps TPN with colour coded heat shrinkable sleeve(d) METERING & INDICATIONi) Digital VAF meter with selector switch & 3 Nos ofCT\"s -1 Setii) Indication lamps for R,Y,B phases -1 Set (Set of Three)(e) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled.(f)Manufacturer Name plate and Danger notice board writtenin regional language Hindi and English. Note 1. Layout & specification of panels shall be got approved by GE before placing the order. |
| 98 | Note : A SUM OF RS 1,24,029.00 TOWARDS SCHEDULE OF CREDIT SHALL BE DEDUCTED TO ARRIVE THE CONTRACT SUM |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy