Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-10-2025 | Corrigendum | BOQ | 17-10-2025 |
| Sl. No. | Item Description |
| 1 | Taking down copper/ aluminum point wiring surface type, concealed type, flame proof type(Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc. |
| 2 | Taking down of OldMCB DB of any size |
| 3 | M & L forpoint wiring with PVCinsulated unsheathed 1100 Volts grade single core multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories andearth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressedsteel terminal boxes concealed in wall covered withlaminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screwsall as specified for the following:(a)One light / fan / bellpoint controlled by one switch. |
| 4 | (b)One 5A 2pin/3pin socket out let multipurpose on the same board with other switches. |
| 5 | (c)One 5A 2pin/3pin switch socket out let multipurpose on independent Board. |
| 6 | All as per item No. 03above but wiring complete with 2.5Sqmm for 3 pin 15A socket multipurpose on independent board Note : A penalty of Rs 100 /- per point will be recovered from the contractor for not matching the disturbed surface with original. |
| 7 | Supply & Fix switch piano single poleflush type 5A,240 V one way. |
| 8 | Supply only Bell Push Piano type, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 9 | Supply only ding dong bell.Make: Anchor,Maru,Vinay |
| 10 | supply only Modular 10A bell push Make: Anchor Roma,Havells Reo,Legrand |
| 11 | Supply & Fix switch socket combination 2 in 1 ,5Amps multipurpose flush type. |
| 12 | Supply & Fix switch socket combination 2 in 1,3 pin, 5 and 15 Ampsflush type universal. |
| 13 | Supply Only switch socket Combination box type 3 Pin, 5 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 14 | Supply Only switch socket Combination box type 3/5 Pin, 15 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 15 | Supply Only switch socket Combination without box 3 Pin, 5 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 16 | Supply Only switch socket Combination without box 3/5 Pin, 15 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 17 | supply only Ceiling Rose surface bacelite 3 terminal, 230 V Comptete all as specified and directed. Make - Anchor/ Vinay/ Leader |
| 18 | S & F in repairs Ceiling fan regulator electronic stepped type, AC, 230 Volts, flush type. |
| 19 | Supply Only Fan regulator electronic type 5 step, 230 V Comptete all as specified and directed. Make - Anchor/ Vinay/ Leader |
| 20 | Supply only Modular Fan regulator electronic type 5 step, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 21 | S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitablefor LED tube 20/22 watts, 230 volts alongwith tube rod 22 watt (double side connection),including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO |
| 22 | S&F in Repairs/Replacement Ultra brightglass LED tube rod 20 Watts(Single/Double side connection), 230 volts with very high efficacy with G13 lamp holder including fixing arrangements and taking down old unserviceable tube rod complete. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO |
| 23 | Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO |
| 24 | Supply and fix decorative recessed type LED light fitting 35/36 watt (size 2\"x2\") and including driver unit, including provision of 3 core copper flexible cable 1.5 Sqmmfrom ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements complete etc.Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO |
| 25 | S&F in repair of building Security lightfitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge.Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ CROMPTON |
| 26 | M & L for GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge |
| 27 | Taking down carefully and Re-fixing of the same ceiling fan 1200mm sweepincluding provision of cable from ceiling nose/ conductor to fan and spray painting of ceiling fan with two coats of synthetic enamel paint, after preparation of surfaces, complete all as specified and directed. |
| 28 | S&F of ACB including drawing/taking out from LT Panel, cleaning the Contacts,checking the breaker accessories, replacing the burnt out control wiring, burnt fuse units, old unsversiable spring units for proper function and carrying out ratio testby applying primary injection all for LT ACB 630 Amps to 800 Amps and refixing the breaker in position and testing all as directed by Engineer in Chare at siteNote :The Contractor shall brought all T & P and testing equipments. |
| 29 | Supply And Fix in repairs MCCB DB TPN 4Way double door125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nosb) Bus bar, Din rail , Neutral linkMake -Havells/Indoasaian/Legrand/ABB/Schnider |
| 30 | Supply And Fix in repairs MCCB DB TPN 8 Way double door125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories & connecting of existing cables & providing of acbel glands, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nosb) Bus bar, Din rail , Neutral linkMake - Havells/Indoasaian/Legrand/ABB/Schnider |
| 31 | Supply & Fix MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs The DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 32 | Supply & Fix MCB DB Double Door SPN 4 way 240 volts including connecting up with existing cable with new lugs. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider |
| 33 | Supply & Fix MCB DB Double Door SPN 8 way 240 volts including connecting up with existing cable with new lugs. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider |
| 34 | Supply & FixMCB DB Double Door SPN 12 way 240 volts including connecting up with existing cable with new lugsThe DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 35 | Supply & Fix MCB DB TPN 4 way 415 V double door with busbar including connecting up with existing cable with new lugs The DB Shall be of Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 36 | M&L for MCB SP, 240 volt, 5 to 32 Amps, 10 KA, C Curve, Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 37 | M&L for MCB SPN, 240 volt, 6 to 63 Amps, 10 KA, C Curve, Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 38 | M&L for MCB TPN, 240 volt, 40 to 100 Amps, 10 KA, C Curve,Make -Havells/Indoasaian/Legrand/ABB/Schnider |
| 39 | S&F single pole and neutral enclosure with a two pin and earthand metal cladplug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified and directed. Make - indoasain/Legrand/Havells |
| 40 | Supply and fix in repair Earthed Metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SP all as specified and directed. |
| 41 | M&L for sub mainwiring with twosingle core 6.0 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 6 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directed.(Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire)Note : 1.Two runs ofcable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit. |
| 42 | M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification. |
| 43 | M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 4.25 M deep below normal GL) with top edge of the plate not less than 3.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 5 of SSR Pt-I 2009 specification. |
| 44 | S&F GI strip size 25 x 4 mmall as directed including welding brazing and taking down of old copper strips as required at site |
| 45 | Material and labour for carrying out vaccum test, pressure test and detecting leakage rectifying the leak and charging the refrigerant (R-22) complete for Tower/split/window type A/C of any capacity complete all as specified and directed.Note : (i) Job includes dismentling equipment from any site, height and transporting to workshop if necessary and reinstalled in situ and testing(ii) Above Job to be guaranteed for minimum one year |
| 46 | All as per item No. 45.00 above but for water cooler of any capacity complete all as specified and directed. |
| 47 | All as per item No.45.00 above but suitablefor refrigertor/ deep freezer of any capacity complete all as specified and directed. |
| 48 | M & L for repairs to base/body/stand of water cooler of any capacity by cutting out rusted portion, replacing with new M.S sheet of existing gauge including finishing wall surface and painting complete body of water cooler of any capacity complete all as specified and directed.Noe :- Job includes dismantling equipment transporting to workshop and back included\" re-installing in situ. |
| 49 | Supply and fix in repairs chasis made out of 2mm thick MS sheet suitable for 1.5 TR/ 2.0 TRcapacity window type AC including dismantling accessories and re-installing on new chasis,painting complete body and required parts incld connection with new wiring etc all as directed |
| 50 | Material and labour for servicing of A/C window type or split type A/C, tower ACof capacity1.5/2/2.5 TRincluding washing with sodash the cooling coil/condensor coil base body drying with air blowerchecking complete wiring testing and re-installing in situ and testing the unit. |
| 51 | M & L for dismentling unserviceablecompressor from the window type AC, Split type A/C 1.5 TR/ 2.0 TR capacity from any location , supply and fix new hermatically sealed compressor unit , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testingall as directed and specified.Make : Voltas/Carrier/Kirloskar /bluestarNote : (i)Job including removing A/C from any site/height/location(ii)Transporting A/C unit to repair workshop and back to site(iii) Loading/unloading etc |
| 52 | All as per item No.51.00 above but suitable for refrigerator 165 to 320 ltrs capacity complete all as specified and directed. |
| 53 | All as per item No.51.00 above but suitable for water cooler 40 t0 150 ltrs capacity complete all as specified and directed. |
| 54 | All as per item No.51.00 above butsuitable for deep freezer of 200 to 500 ltrs capacity complete all as specified and directed. |
| 55 | Supply and fix in repair AC fan motor for window/splittype A/C of 1.5/2 TR ,Tower AC 2.5 TRcapacity single phase 230 volt 50 HZ complete with fan blade/blower includingany addition/alteration to suit new fitting of motor. |
| 56 | All as per item No. 55.00 above but for Water cooler any capacity complete all as specified and directed. |
| 57 | All as per item No. 55.00 above but for deep freezer any capacity complete all as specified and directed. |
| 58 | Supply and fix in repairRelay for A/C split/window type,Tower AC complete all as specified and directed. |
| 59 | Supply and fix in repair Relay for WATER COOLER/DEEP FREEZER complete all as specified and directed. |
| 60 | Supply and fix in repairThermostat for A/C 1.5 TR/2 TR,Tower AC complete all as specified and directed. |
| 61 | -ditto- all as per item No 16 but for water cooler of any capacity complete all as specified and directed. |
| 62 | Supply and fix in repair Air filtter for window type/split type AC, Tower AC as per sample complete all as specified and directed. |
| 63 | Supply and fix in repairStarting capacitor 80-100 mfd 220 volt 50 HZ complete all as specified and directed. |
| 64 | Supply and fix Starting capacitor of capacity 120 - 150 MFD for 2 TR, 2.5 TR capacity complete all as specified and directed. |
| 65 | Supply and fixing in repairof Running capacitors ofcapacity 45 MFD220 volt50Hz complete all as specified and directed by Engr-in-Charge |
| 66 | All as per item No. 64.00 above but 36 MFD complete all as specified and directed. |
| 67 | All as per item No. 64.00 above but 6 MFD complete all as specified and directed. |
| 68 | All as per item No. 64.00 above but 4 MFD complete all as specified and directed. |
| 69 | Supply and fix in repair 4 core 4 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade complete all as specified and directed. |
| 70 | Supply and fix in repair 4 core 2.5 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade complete all as specified and directed. |
| 71 | M & L for power point wiring with PVC insulated sheathed copper wire 4 Sqmm size 1100 volts grade IS-654 in and including PVC casing and capping with all accessories including one run of 4 Sqm earth lead wire all as directed and specified. |
| 72 | Supply and fix in repair copper tube of size 6 mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specifiedby Engineer -in-charge |
| 73 | Supply and fix in repair copper tube of size 10 mm bore including brazing etc with rubberised insulation and tapesuitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge. |
| 74 | Supply and fix in repairs 8 mm dia hand shut off valve complete all as specified and directed. |
| 75 | Supply and fixing in repair and testing fan blade of motor for water cooler of 80/100/120/150 Ltrs capacity including removing old fan blade. |
| 76 | Supply and fixing in repair and testing fan blade suitable for window type Air conditioner of 1.5 Ton/2 Ton capacity including removing old fan blade. |
| 77 | Supply and fix in repairs front grill as per sample suitable for window type AC 1.5 TR/2 TR capacity. |
| 78 | Supply and fixing in repair of blower drum suitable for window type Air concitioner of capacity 1.5Ton /2TON. |
| 79 | Supply and fix in repair stainless steel tank of capacity 40 ltrs capacity water cooler of existing size shape |
| 80 | All as per item No 79.00 above but80 ltrs capacity complete all as specified and directed. |
| 81 | All as per item No 79.00 above but 120 ltrs capacity complete all as specified and directed. |
| 82 | Supply and fix in repairwaste water tray suitable for single/double tap with waste hose complete all as specified and directed. |
| 83 | Supply and fix in repair PVC float valve wih PVC ball suitable for 15mm dia complete all as specified and directed. |
| 84 | Supply and fix in repairs bibtap push type stainless steel 15mm dia complete all as specified and directed. |
| 85 | Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm complete all as specified and directed. |
| 86 | Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 15mm complete all as specified and directed. |
| 87 | Supply and fix in repairs remote sensor kit with Manual control pendent suitable for split type A/C,Tower AC1.5 TR to 2.5 TR capacity work on 230 volt SP 50 HZ complete all as specified and directed. |
| 88 | Supply and fixbase tray suitable A/C 1.5/2 TR made out of 2mm thick of existing size and shape including painting one coat zine chromered oxide and two coats of synthetic enamelled paint complete all as specified and directed. |
| 89 | Supply and fix in repairs condensor coils suitable for 1.5 TR to 2.5 TR capacity including dismentling old one brazing, testing, leakage rectification all as directed. |
| 90 | Supply and fix in repairs cooling coil suitable for 1.5 TR to 2.5 TR A/C of existing model including taking out old defective coil, brazing work, brass charging to full pressure complete all as specified and directed. |
| 91 | Supply and fix in repairs thermal over load relay 415 volts 66 - 110 Amps rating MMX R-4 model complete all as specified and directed. |
| 92 | Supply and fix in repairs thermal over load relay 415 volts 32 - 50 Amps rating MMX R-4 model complete all as specified and directed. |
| 93 | M&Lin repair for wall mounted powder coated MS bracket suitable for 1.5TR/2TR Split type AC, Towre AC 2.5 TR out door unit |
| 94 | M&L for repair of rubberised insulation and tape for copper tubes of size 6mm/10mm complete all as specified and directed. |
| 95 | Supply and fix PVC drain pipe of size 5/8\" bore for supply pipes for air conditioners complete all as specified and directed. |
| 96 | Supply only in repairs cordless remote control unit suitable for capacity of 2 / 1.5 Ton suitable for window/ Split AC complete all as specified and directed. |
| 97 | Supplyand Charging of non CFC Refrigerant Gas R -410/32/22 all as specified and directed. |
| 98 | Material and labour for taking down/ Up and shifting of Window type AC or Split type A/C, Tower ACof capacity1.5/2/2.5 TR with mounting bracket including washing cooling coil/condensor coil base body drying with air blower complete all as specified and directed. |
| 99 | Daily door to door repair/replacement of maintenance for Md Accn bldg covered under GE(NW) Mankhurd (a) Mahul Area by team of contractor\"s comprises of (a) One Electrician and 01 x Helper will be carried out daily under restective area :- Note 1 :-(a) Contractor will be assigned to visit one area daily alongwith man and material as per as per direction of Engineer-In-Charge and he will perform all petty repair work as demanded by user of bldg.(b) Contractor will make his own arrangement for to and fro of his team and his rates shall be inclusive of this aspect. (c) The material component require for above complaint will be measured and paid as “Supply only” under respective item of this schedule.Certain material may be issued from the department free of cost for fixing only as per direction of Engineer-in-Charge. (d) If contractor fails to attend the area, a sum ofRs 4000/- per days will be recovered on account of non attedance of petty repair work from any legitimate payment due to contractor. A sum of Rs 500 per false complaint/wrong signature will also be recovered from the contractor.(e) Contractor will also attend the petty repair work on all days of week i.e Working day as per direction of Engineer-in-Charge.(f) Contractor will obtain log sheet of repair work perform by him duly signed by occupant user and authorised user rep both.(g) Rep of contractor, Rep of GE Office and Rep of User alongwith labour team (Carpenter, Plumber, Electrician and helper) will visit door to door and get the user complaint and rectified on the same day.(h) A detailed log of complaints with completion/ non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him.(j) The contractor will make suitable arrangment for emergent complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.(k) The quoted rate deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site.(l) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed peridically by Engr-in-charge to streamline complaints disposal system. (n) Dress like Dangri and other for labours to be provided contractor as per direction of Engineer-in-Charge.(o) Contractor will arrange all the T&P for his labours with aluminium ladder as required.Note 2. The whole team will visit daily and perform complaint resolution door to door as per users satisfactio |
| 100 | All as per Item No 99 above but of ThaneArea |
| 101 | Supply only Piano switch 6 Amp, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 102 | Supply only Modular type switch 6/ 10 Amp one way, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 103 | Supply only Modular type switch 16 Amp one way, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 104 | Supply only Modular type socket 6/16 Amp one way, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor |
| 105 | Supply only Fan capacitor 2.5 Mfd Comptete all as specified and directed. Make - Tibcon/ Capcon/ Havells/ Epcos |
| 106 | Supply only FRLS PVC Copper Wire 1.5 Sqmm roll of 90 Meters complete all as specified and Directed Make : Havells/Polycab/Anchor/KEI |
| 107 | Supply only LED Bulb of 9/10 watt operating on 230 V, 50 Hz, AC supply suitable for wellglass fitting complete all as specified and directed. Make - Wipro/ Baja |
| 108 | Supply only PVC insulation tape of 6.5 Meter of size 1.8cm x 0.125mm of suitable sizeComptete all as specified and directed. |
| 109 | Supply only MCB SP 240 V 5 Amp to 32 Amp, 10 KA Comptete all as specified and directed. Make - Wipro/ Legrand/ Havells |
| 110 | Supply only MCB SPN 240 V 10 Amp to 32 Amp, 10 KA Comptete all as specified and directed. Make - Wipro/ Legrand/ Havells |
| 111 | Supply only MCB SPN DB 8 way Double door Comptete all as specified and directed. Make - Wipro/ Legrand/ Havells |
| 112 | Supply only cotton cloth for cleaning of electrical tools Comptete all as specified and directed by Engr-in-Charge |
| 113 | Supply only Plug top 3 pin 15/16 Amps capacity Comptete all as specified and directed. Make - Anchor/ Havells |
| 114 | Supply only Plug top 3 pin 5 Amps capacity Comptete all as specified and directed. Make - Anchor/ Havells |
| 115 | Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismentaling of blades canopy down rod etc & remove to store for repair. & Refix the same including provision of 3 core 0.5 sq mm copper flexiable cable from ceiling rose to connector.Note(i) The representative of the contrcator shall report to Engineer-in-charge/JE on daily basis to carry out repairs to fan and the defects should be rectified on the same day |
| 116 | M&L for Opening of cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge. Note - Spares such as Bearing, Capacitor, Capacitor Clamp, Rubber insulator will be measured seperately under respective item of this schedule :(a)Ceiling fan 1200 / 1400 mm Sweep. |
| 117 | (b) Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep. |
| 118 | (c)Exhaust Fan, Pedastal fan,wall fan,450/600 mm Sweep. |
| 119 | Painting onlyof ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, sscraping out of old paint filling of cavities with filler preparationof body and cleaning of dust etc Painting by Spray with first Quality Paint including over quot ofzinc primer writing ofMes number complete for allas directed :- |
| 120 | Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing Note : Spares shall be measured & paid resperative item of this sch. |
| 121 | Supply only spare parts to be incorporated for repairing fans in respective item of this schedule :(a) Capacitor up to 2.5 Mfd MAKE KELTRON,EPCOS |
| 122 | (b) Capacitor 3.15/ 4 MFDMAKE KELTRON,EPCOS |
| 123 | (c) Capacitor Clamp with Connector As Par Sample |
| 124 | (d) Rubber Insulator sutiablefor any type ofCeiling Fan. |
| 125 | (e) Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample |
| 126 | (f) Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample |
| 127 | (g) Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc mplete 300 mm sweepas par sample |
| 128 | (h Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete380/ 450 mm sweepas par sample |
| 129 | (j) Ball bearing sutiable for any type of fans Make : SKF,TATA,NBC |
| 130 | (k) Mild steel shaft as per sample for any fan |
| 131 | (l) Ceiling Fan Blade suitable for 1200/1400 mm sweep as per sample. |
| 132 | (m) Exhaust Fan Blade suitable for 300 mm sweep as per sample. |
| 133 | (n) Exhaust Fan Blade suitable for 450 mm sweep as per sample. |
| 134 | (o) Pedestal/WallFan Blade suitable for 450 mm sweep as per sample. |
| 135 | (p) Pedestal / Wall Fan Blade suitable for 600 mm sweep as per sample. |
| 136 | Supply & Fix Exhaust fan louvers with shutter made of aluminium sheet of 0.5 mm thickness, and frames made out of mild steel, making good the distrubed surfaces in CM 1:4,including scafolding if any required to carry out the work in building of height up to 32 Meters complete in all respects the |
| 137 | Deployment of Technician for Fan checking, Fan Servicing / Safety Hook/ Pin including fixing of safety pin, nut, bolt etc. complete and entry in register duly signed by User/ Occupants.Techniia will Carry scheduled preventative maintenance checks as per details to be given by Site Executive. |
| 138 | M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable piano switch 5 Amps & refixing switch plate and testing complete all as directed.Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza |
| 139 | M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable fan regulator & refixing switch plate and testing complete all as directed.Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza |
| 140 | S&F,in repair PVC laminated ISI marked top cover 3 mm including cutting/drilling holes for mounting housing of switches, sockets, etc as per site requirement suitable for following sizes of sunken/TW board.4”x4” size |
| 141 | -Ditto- all as per Item No 140.00above but 7”x4” size |
| 142 | -Ditto- all as per Item No 140.00above but 8”x6” size |
| 143 | -Ditto- all as per Item No140.00above but 8”x10” size |
| 144 | -Ditto- all as per Item No140.00above but 10”x12” size |
| 145 | M & L taking down from positionexisting defective storage water heater 25 to 50 ltre storage Capacityfor carrying outrepairs work such as replacing worn out parts and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, painting with two coats of white synthetic enameled paint by spray paint complete all as specified and directed |
| 146 | Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed Make :- Racold/ Bajaj |
| 147 | Supply only non return valvechromium plated brass 15 mm dia heavy-duty all as specified and directedMake :- Racold/ Bajaj |
| 148 | Supply only indicator lamp for geyser red/green, round/square/rectangle as per site requirement 230 V AC all as specified and directed Make :- Mimic / AE |
| 149 | Supply only heating element 1500 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed Make :- Racold/ Bajaj |
| 150 | Supply only heating element 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater all as specified and directed Make :- Racold/ Bajaj |
| 151 | Supply only thermostat suitable for storage water heaters 25to 50 Ltrs capacity adjustabletype i.e.. 0 degree centigrade to 80 degree centigrade all as specified and directed Make :- Racold/ Bajaj |
| 152 | Supply and fix only plug top 3 pin 5 Amps capacityMake: Anchor ISI/LeaderISI/RIDER ISI |
| 153 | Supply and fix only plug top 3 pin 15/16 Amps capacityMake: Anchor ISI/LeaderISI/RIDER ISI |
| 154 | Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 0.75 sqmm 1100 volts grade all as specified and directed. Make Plaza, Havells |
| 155 | Supply and fix in replacement of copper water tank of 25 Ltrs capacity with and including necessary gasket packing, nuts, bolts, etc completeall as directed by Engr-in-Charge. |
| 156 | Fabricating, supply and fixingin replacement geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity forgeysers of any make as per the existing oneall as specified and directed |
| 157 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 158 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 159 | Supply and fixing in repairsSheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts |
| 160 | Supply only LED Driver 150 watts to 350 Watts Suitable for highbay/flood/street light fitting Comptete all as specified and directed. |
| 161 | Supply only LED Driver 30 watts to 60 Watts Suitable for highbay/flood/street light fitting Comptete all as specified and directed. |
| 162 | Note : A SUM OF RS 72993.00 TOWARDS SCHEDULE OF CREDIT SHALL BE DEDUCTED TO ARRIVE THE CONTRACT SUM |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy