| Sl. No. | Item Description |
| 1 | Schedule \"A\" B/R |
| 2 | (i)Consultancy services : Architectural design and drawing (Provision of Officer\"s Gymnasium at ICGS Vadinar):-PLINTH AREA OF BUILDING = 103.70 Sqm (01 Building)(a) Preparation of architectural conceptual plan and elevations and working drawings for the above work along with marking of internal E/M (Electrification & Water Supply) and schedule of finishes as per the approval line plan given.(b) Complete set of architectural working drgs good for tender shall be submitted in the form of hard copy (01 Set) and soft copy on CD at the time of obtaining completion of the job.(c)All drgs shall be prepared on A2 size sheets unless found necessary to use larger sheet sizes.(d)Detail drgs of all features shall be prepared at min 1:50 scaleand all other drgs shall be prepared at 1:00 scale except site plan which be prepared at scales appropriated to fit in A2 size paper.(ii)Consultancy services : Structural design and drawing:-(a) Preparation and submission of self-sufficient structural design and drawings including structural details, structural notes confirming to latest standards IS-456, IS-800, IS-816, IS-1893, IS-2062, IS-4326, IS-13920 and any other latest and relevant Indian Standard of the buildings as per the architectural drawings. The parameters for structural design are as under:-(b) Construction of Indoor Gymnasium Building with Permanent specifications with RCC framed structure/construction using M-30 Design Mix, complete including internal services. |
| 3 | PLINTH AREA OF BUILDING = 103.70 Sqm (01 Building)(a)The design shall include the followings parameters:-(i) Reinforcement steel shall CRS Fe-500D grade TMT bars. The grade of concrete shall be M-30 (Design Mix) for Building/Structure.(ii) Foundation shall be RCC isolated/combined footing/Raft/mat fdn as per requirement.(iii)Seismic Zone-IV.(iv)SBC (Tentative 20 T/Sqm at 1.5m depth for isolated footing. (v) The structure is single storey building above ground. Any other relevant details required shall be taken from GE (I) CG Porbandar.(b) Design and analysis to be done using STAAD & final output to be using RCDC software. Supply of Design calculations folders along with STAAD model and output file both in hard and soft copy (02 X CD) (each copy).(c) Supply of 01 set of original tracing hard copy (A1 Size on 100 micron laser film) pm Gateway/Nova Cad brand film paper along with a soft copy (02 X CD) in AutoCAD of Drawings, as directed. The design prepared by one Designer shall be checked by another Designer and both the persons shall sign the design calculations and drawings along with date.d) The supplier/bidder shall give free of cost clarification, if any, during acceptance at tender & complete execution period of the building. |
| 4 | (e) Any amendment required during execution shall be made by the Consultant and requisitecopies of amendment sheets shall be submitted free of cost. (f)The Consultant/Designer shall discuss the preliminary design & Drawings before final Structural Design with GE (I) CG Porbandar. (g) The responsibility for the structural design & drawings prepared rests with the supplier. In case of any defect/damage detected in the designed structure during, its design life and the same is attributed to faulty drawing/design, the supplier will be liable for penalty of 10% of the total project cost. (h) Third party vetting/proof checking. The suppler shall be responsible for third party vetting/proof checking from Any Government Engineering Collage duly signed by authorized signatory Structural Designer on behalf of the institute and not from a professor/individual of the institute in his personal capacity. The third party vetting the Designs, Drawings shall also be liable for ensuring that the Designs & Drawings are in compliance as per the laid down standards, latest codes, regulations adherence to NBC norms and sound Engineering practices. The supplier/bidder is responsible for obtaining clarification from the vetting agency till the completion of project. |
| 5 | (j)A certificate that all details have be thoroughly checked and are in compliance to standards, codes, regulations in respect of safety, soundness and economy shall be obtained from the vetting agency. (k) The vetting agency will also be liable and answerable for any design deficiencies detected during design life of the building and may be called upon to address such issues if any. (l) On Preparation of the design folder and preliminary structural drawings, the bidder shall send this design team to make a detailed power point presentation of the structural design and drawings to GE (I) CG Porbandar and E-6 Section of GE(I) CG Porbandar. The date of presentation by the bidder\"s design team shall be decides in consulation with GE(I) CG Porbandar. (m) The final structural drawings duly vetted by authorities as mentioned in BOQ shall be submitted to GE (I) CG Porbandar by the supplier/bidders Design team for final approval and the bidder team should come prepared to make any corrections/amendments to the same if required in consultation with GE (I) CG Porbandar. (n) The supplier/bidder\"s design team shall have to visit GE (I) CG Porbandar at any time during the planning and execution of the work if required, an being intimated in writing by GE (I) CG Porbandar. (0) Nothing extra shall be payable for the above visits of bidder\"s design team to GE (I) CG Porbandar. |
| 6 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft /loose soil, complete all as specified & directed by Engineer-in-Charge. |
| 7 | Removing (soil) excavated materials not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified & directed by Engineer-in-Charge. |
| 8 | Supply only Moorum/red bajri, complete all as specified & directed by Engineer-in-Charge. |
| 9 | Material & Labour for forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing to required size, shape, etc. not exceeding 1.5 Metre high from base, complete all as specified & directed by Engineer-in-Charge. |
| 10 | Excavation in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre depth for foundation, or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth, and getting out in soft/loose soil, complete all as specified & directed by Engineer-in-Charge. |
| 11 | Material & Labour for Plain Cement Concrete Type D-2 1:4:8 (using 40mm graded granite stone aggregate) in foundations, filling and mass concrete, complete all as specified & directed by Engineer-in-Charge. |
| 12 | Material & Labour for Pre-cast cement concrete block masonry type C-1, 1:3:6 (20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified & directed by Engineer-in-Charge. |
| 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/disintegrated rocks, complete all as specified & directed by Engineer-in-Charge. |
| 14 | Use and Waste of form work to sides of footing for fair finished surfaces, complete all as specified & directed by Engineer-in-Charge. |
| 15 | Use and Waste of form work to sides of columns for fair finished surfaces, complete all as specified & directed by Engineer-in-Charge. |
| 16 | Use and Waste of form work to sides of Beam for fair finished surfaces, complete all as specified & directed by Engineer-in-Charge. |
| 17 | Use and Waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified & directed by Engineer-in-Charge. |
| 18 | Use and waste of Form work to chajjas, troughs and chulla-hoods and similar items including edges for fair finished surfaces, complete all as specified & directed by Engineer-in-Charge. |
| 19 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified & directed by Engineer-in-Charge. |
| 20 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Chajjas, complete all as specified & directed by Engineer-in-Charge. |
| 21 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified & directed by Engineer-in-Charge. |
| 22 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in Beams, Cantilevers, bressummers, complete all as specified & directed by Engineer-in-Charge. |
| 23 | Material & Labour for Reinforced cement concrete (design mix M-30) (20mm graded aggregate) as in roof Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified & directed by Engineer-in-Charge. |
| 24 | Supply & Fixing CRS Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & directed by Engineer-in-Charge. |
| 25 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified & directed by Engineer-in-Charge. |
| 26 | Material & Labour for rendering 15mm thick on fair faces of Brick work/PCC block masonry or Concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement, complete all as specified & directed by Engineer-in-Charge. |
| 27 | Material & Labour for rendering 10mm thick on fair faces of Brick work/PCC block masonry or Concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement, complete all as specified & directed by Engineer-in-Charge. |
| 28 | Material & Labour for rendering 5mm thick on ceiling concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, complete all as specified & directed by Engineer-in-Charge. |
| 29 | Material & Labour for hard-core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified & directed by Engineer-in-Charge. |
| 30 | Material & Labour for 75mm thick PCC (1:3:6) Type C-1 (20mm graded stone aggregate as in plinth protection laid in alternative panels, complete all as specified & directed by Engineer-in-Charge. |
| 31 | Material & Labour for PCC 1:4:8, Type D-2 (using 40mm graded granite stone aggregate) in sub base, complete all as specified & directed by Engineer-in-Charge. |
| 32 | Material & Labour for granite 18 to 20mm thick (of any type) tiles, machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture or pigment to match the shade of granite stone including grinding and polishing, moulding edges as directed and making hole for gas pipe if required complete including 15mm thick rendering in Cement Mortar 1:4 as backing, complete all as specified & directed by Engineer-in-Charge. |
| 33 | Material & Labour for 25mm thick cement concrete type B-0, 1:2:4(using 12.5mm graded aggregate) as in levelling course in flooring, complete all as specified & directed by Engineer-in-Charge. |
| 34 | Material & Labour for Non - skid Ceramic tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm screed bed or bedding layer in 1:4 Cement Mortar, complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Material & Labour for Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in Cement Mortar 1:4 on vertical surface, complete all as specified & directed by Engineer-in-Charge. |
| 36 | Material & Labour for supertuf rubber tiles 20mm thickness ideal for free weight areas, heavy lifting zones and cross training boxes as well protective flooring for heavy gym equipment’s, of size 24 inches x 24 inches each set and jointed in interlocking design, complete all as specified & directed by Engineer-in-Charge. |
| 37 | Supply & Fixing size of grid 605 x 605mm GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having curled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre, complete all as specified & directed by Engineer-in-Charge. |
| 38 | Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified & directed by Engineer-in-Charge. |
| 39 | Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturer’s instructions, complete all as specified & directed by Engineer-in-Charge. |
| 40 | Providing and fixing 10mm thick plaster of Paris ceiling (Gypsum anhydrous) to curved surface over 2nd class softwood fillets, or metal frame work and reinforced with GI wire mesh, complete all as specified & directed by Engineer-in-Charge. |
| 41 | Material & Labour for preparation of ceiling surfaces and applying two coat of oil bound distemper over a coat of primer, complete all as specified & directed by Engineer-in-Charge. |
| 42 | Material & Labour for preparing plastered or un-plastered new wall surfaces applying two coats of Oil Bound distemper over coat of cement primer, complete all as specified & directed by Engineer-in-Charge. |
| 43 | Material & Labour for granules textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kg per Pack) made of 92% silica particles coated with fade resistant pigment, 100% acrylic polymer bonding agent (5 Kg per pack) with the applied thickness of the coating being between 0.8mm -1.2mm to be applied on curved, smooth level plaster without key, as per manufacture directions, for usages to be applied and approved applicator of the manufacture as per the direction/ supervision of the Engineer-in-charge, all complete. The above textured coating should conform to surface spread of flame class one of BS 476:Part 7:1971 and pull off strength of the coating to meet JISA 6909 on smooth plastered surfaces, complete all as specified & directed by Engineer-in-Charge.Make:- Bakelite Hylam Limited or equivalent make approved by the GE. |
| 44 | Supply & Fixing factory made uPVC white colour fixed window/ventilator made of extruded profile with wall thickness of 2.3 mm (±2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (one vertical length in between two shutters) (60mm x 74mm). Glazed bead (35mm x 20mm) will be metered cut and fusion welded at all corners. including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick. galvanized steel frame (28mm x 21.5mm), T profile (27mm x 17mm) to be inserted in repair profile. Frame will be fixed to the wall with 8mm x 100mm long fasteners. 5mm thick glazing with selected quality glass, complete all as specified & directed by Engineer-in-Charge. (Note: The unit rate included cost of glass and included all other connected accessories.) area not exceeding 1.00 sqm each fixed |
| 45 | Supply & Fixing factory made uPVC white colour Sliding Window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 ±0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories, complete all as specified & directed by Engineer-in-Charge. (Note: The unit rate quoted by contractor included cost of glass and included all other connected accessories. Net opening will be measured for payment purpose) (A) Area not exceeding 2.00 sqm each |
| 46 | Material & Labour for powder coated aluminium Door frame made of91 x 43 x 1.50mm sections and shutters made of 39.4 x 17.7 x 1.50mm thick sections with 4mm thick tinted glass / ACP panel including hinges, sliding door bolts, locking arrangement, tower bolts, handle and door closer, complete all as specified & directed by Engineer-in-Charge. |
| 47 | Material & Labour for powder coated aluminium Deco grill/chequered mesh of size 75mm x 75 mm including \"U\" channel etc; fixed, complete all as specified & directed by Engineer-in-Charge. |
| 48 | Supply & Fixing 10-12mm thick toughened frosted glass including rounding to edges for partition or door along with all accessories including top pivot, bottom pivot, top patch, floor springs, H type handle, patch lock etc., complete all as specified & directed by Engineer-in-Charge. |
| 49 | Material & Labour for 10mm thick rendering in cement mortar 1:4 mixed with water proofing compound including brushing with neat cement slurry @ 3kg per Sqm as in roofs (water proofing compound shall be measured separately), complete all as specified & directed by Engineer-in-Charge. |
| 50 | Supply only integral water proofing compound, complete all as specified & directed by Engineer-in-Charge. |
| 51 | Supply and laying HYPERPLAS-STANDARD 3.0 Kg/sqm polymeric water proofing membrane incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sqm, followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2 kg/Sqm each at the top and bottom and applying of one coat of aluminium paint on the membrane complete including sealing all joints by themo fusion with minimum 10cm overlap all as per manufacturer’s instructions, complete all as specified & directed by Engineer-in-Charge. |
| 52 | Material & Labour for 40mm thick PCC 1:2:4, Type B-0 (using 12.5mm graded granite stone aggregate) in roof covering, complete all as specified & directed by Engineer-in-Charge. |
| 53 | Supply and fixing Heat Resistant Terrace Tiles (300mm x 300mm x 10mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150mm height along the parapet walls in the same manner, complete all as specified & directed by Engineer-in-Charge. |
| 54 | Supply and fixing 1000 litres capacity triple layer, rotational moulded, polythene water storage tank with cover (Cylindrical vertical with closed top), colour white,hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc., and including 25mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe along with 25mm gate valve, complete all as specified & directed by Engineer-in-Charge. |
| 55 | Supply & Fixing tubular towel rail, 20mm dia., D type, 60 cm long between flanges of brass chromium plated, complete all as specified & directed by Engineer-in-Charge. |
| 56 | Supply & Fixing soap dish of chromium plated fixed to plugs with chromium plated screws, complete all as specified & directed by Engineer-in-Charge. |
| 57 | Supply & Fixing corner glass shelf assembly of 12-inch size fixed to plugs with chromium plated screws, complete all as specified & directed by Engineer-in-Charge. |
| 58 | Supply & Fixing of health faucet 1mtr length with all accessories, complete all as specified & directed by Engineer-in-Charge. |
| 59 | Supply & Fixing PVC (SWR) pipes single socketed in any length with rubber ring joints and accessories laid in floors/wall of 110mm bore, complete all as specified & directed by Engineer-in-Charge. |
| 60 | Supply & Fixing PVC (SWR) bends 110mm, complete all as specified & directed by Engineer-in-Charge. |
| 61 | Material & Labour for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia fixed, complete all as specified & directed by Engineer-in-Charge. |
| 62 | Material & Labour for Bevelled edge mirror, 600mm x 450mm of selected quality glass, mounted on 6mm thick or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified & directed by Engineer-in-Charge. |
| 63 | Material & Labour for full length classic mirror of 5mm thickness rectangular in shape of any size fixed over 12mm high grade pre-laminated particle wood board along with hanging clips and wooden frame all around the mirror, complete all as specified & directed by Engineer-in-Charge. |
| 64 | Material & Labour for Ceramic white colour EWC with seat cover and dual flush tank single body wall mounted type, complete all as specified & directed by Engineer-in-Charge. |
| 65 | Material & Labour for Vitreous China ware wash hand basin white, flat back, size 550mm x 400mm size with cutting for and pinning ends of brackets or erecting stand including CP waste coupling, 32mm dia PVC waste pipe fixed, complete all as specified & directed by Engineer-in-Charge. |
| 66 | Supply & Fixing 15mm diafancy type CPtap of brass type cast copper alloy with crutch or butterfly handle, complete all as specified & directed by Engineer-in-Charge. |
| 67 | Supply & Fixing brass CP shower rose 75mm size fancy type with swivel joint any size including fixing to steel pipe/union for 15mm dia., complete all as specified & directed by Engineer-in-Charge. |
| 68 | Supply & Fixing PVC connection of 15mm dia length 600mm with PTMT nuts fixed, complete all as specified & directed by Engineer-in-Charge. |
| 69 | Supply & Fixing stop valve 15mm dia., caster copper alloy, screwed down, high pressure fancy type chromium plated screwed of both ends for iron pipe or for unionswith long shank and cup (concealed type), complete all as specified & directed by Engineer-in-Charge. |
| 70 | Supply & Fixing Angle cock 15mm dia., caster copper alloy, screwed down, high pressure fancy type chromium plated, complete all as specified & directed by Engineer-in-Charge. |
| 71 | Supply & Fixing Peg set of three made of teak wood and Aluminium pegs of size 10cm, complete all as specified & directed by Engineer-in-Charge. |
| 72 | Supply & Fixing CP Grating 100mm dia fixed, complete all as specified & directed by Engineer-in-Charge. |
| 73 | Supply and fixing 32mm outer dia CPVC pipes SDR 11 & plain CPVC SER 11 fittings including bends, elbows, unions etc., fixed on wall concealed or exposed /ceiling or laying in floors, complete all as specified & directed by Engineer-in-Charge. |
| 74 | Supply and fixing 25mm outer dia CPVC pipes SDR 11 & plain CPVC SER 11 fittings including bends, elbows, unions etc., fixed on wall concealed or exposed /ceiling or laying in floors, complete all as specified & directed by Engineer-in-Charge. |
| 75 | Supply & Fixing PVC waste pipe of 32mm dia., complete all as specified & directed by Engineer-in-Charge. |
| 76 | Supply & Fixing 15mm bore pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shank and fly nuts screwed for iron pipes, complete all as specified & directed by Engineer-in-Charge. |
| 77 | Material & Labour for preparation of new or previously untreated Surfaces of steelany description, over10cm in width or girth, not otherwise describedover a coat of zinc primer and applying two coats of synthetic enamel paint, complete all as specified & directed by Engineer-in-Charge. |
| 78 | Supply & Fixing Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290. Gde-E-165, complete all as specified & directed by Engineer-in-Charge. |
| 79 | Material & Labour for sand filling under floor or in foundations including watering and consolidation, complete all as specified & directed by Engineer-in-Charge. |
| 80 | Material & Labour for machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Gde with grey cement and pigment, complete all as specified & directed by Engineer-in-Charge. |
| 81 | Material & Labour for 100mm thick plain cement concrete 1:4:8 type D-2, using 40mm graded stone aggregate, as in sub base to floors and paving, lean concrete to fdn etc., complete all as specified & directed by Engineer-in-Charge. |
| 82 | Material & Labour for preparation of old decorated plastered surfaces of wall including cornices, pilasters etc. and applying two coat of white wash, complete all as specified & directed by Engineer-in-Charge. |
| 83 | Material & Labour for PCC 1:3:6 type C-2 an in fdn of manholes, complete all as specified & directed by Engineer-in-Charge. |
| 84 | Material & Labour for PCC 1:3:6 type C-2 as in bed to drain pipes including packing under and hunching against the sides of pipes after they are laid and tested for RCC NP-2, 150mm bore pipe, complete all as specified & directed by Engineer-in-Charge. |
| 85 | Material & Labour for PCC 1:2:4 type B-1 as in coping, surface channels, benching, etc., of manholes finished fair and even, complete all as specified & directed by Engineer-in-Charge. |
| 86 | Material & Labour for precast manhole covers with plain faces using RCC 1:2:4 type B-1 and set in Cement Mortar 1:4 including formwork, complete all as specified & directed by Engineer-in-Charge. |
| 87 | Supply & Fixing 150mm bore Reinforced concrete pipes, class NP-2, laid and jointed complete with collars, including all levelling, complete all as specified & directed by Engineer-in-Charge. |
| 88 | Extra for forming fair finished channel or drain 30cm girth (inner girth) in cement concrete using extra cement incl forms, moulds, stopped end, etc., complete all as specified & directed by Engineer-in-Charge. |
| 89 | Material & Labour for MS work such as rungs, handles to manholes, etc., complete all as specified & directed by Engineer-in-Charge. |
| 90 | Material and labour for cutting holes in brick wall built in cement mortar or stone wall built in lime mortar exceeding half brick and not exceeding one brick thick for inserting holdfasts and making good dismantling portion in cement mortar 1:3 or cement concrete 1:2:4, complete all as specified & directed by Engineer-in-Charge. |
| 91 | Demolition ofbrick and stone wall built in cement mortar including all quoins, arches, pillars built in cement mortar, complete all as specified & directed by Engineer-in-Charge. |
| 92 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified & directed by Engineer-in-Charge. |
| 93 | Material and labour for preparation of old decorated bybrooming down scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and grease spouts and cleaning with water on wall applying two coats of Acrylic emulsion (exterior weather coat) paint of any tint as approved, complete all as specified & directed by Engineer-in-Charge. |
| 94 | Material and labour for Anti-termite treatment of soil by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified & directed by Engineer-in-Charge. |
| 95 | Material and labour for Anti-termite treatment of soil by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured), complete all as specified & directed by Engineer-in-Charge. |
| 96 | Material and labour for Anti-termite treatment of soil by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all as specified & directed by Engineer-in-Charge. |
| 97 | Material and labour for Anti-termite treatment of soil by treating soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified & directed by Engineer-in-Charge. |
| 98 | Material and labour for Anti-termite treatment of soil by treating soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all as specified & directed by Engineer-in-Charge. |
| 99 | Schedule \"A\" E/M |
| 100 | Material & Labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part- I ISI marked including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 1.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire including modular metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets andfan regulators, complete all as specified & directed by Engineer-in-Charge.for the following:- |
| 101 | For One light point /fan point controlled by one switch with cable 1.5 Sqmm |
| 102 | For one 3 pin socket outlet 5 Amps on the same board with other switches with cable of size 1.5 Sqmm nominal area |
| 103 | For one 3 pin socket outlet 5 Amps independent board withcable 1.5 Sqmm nominal area |
| 104 | Material & Labour for Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part- I ISI marked including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 2.8mm thick Bakelite sheet white/coloured top cover for mounting of modular switches, sockets andfan regulators, complete all as specified & directed by Engineer-in-Charge. for the following:-(a) one 3/5 pin 15/16 Amps socket |
| 105 | Supply & Fixing Modular switch 1 way, 10 Amps, 1 module, complete all as specified & directed by Engineer-in-Charge. |
| 106 | Supply & Fixing Modular switch 1 way, 16 Amps, 1 module, complete all as specified & directed by Engineer-in-Charge. |
| 107 | Supply & Fixing Modular socket, 6 Amps, 2/3 pin combined 2 module, complete all as specified & directed by Engineer-in-Charge. |
| 108 | Supply & Fixing Modular socket, 6/16 Amps, 2/3 pin combined 2 module, complete all as specified & directed by Engineer-in-Charge. |
| 109 | Supply & Fixing Modular fan regulator, 120 watt, 2 modular (ISI marked), complete all as specified & directed by Engineer-in-Charge. |
| 110 | Supply & Fixing 6 A, 250 V high quality robust surface/ flush type polycarbonate/ PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5mm, complete all as specified & directed by Engineer-in-Charge. |
| 111 | Material & Labour for point wiring using lSI marked 1.1 kV grade single core FRLSH flexible cable, conforming to IS:694- 1990, having multi-drawn thin strands of electrolytic copper conductors, conforming.to IS: 8130- 1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm NB PVC medium grade recessed conduits, conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353-1985, including factory made sunken, galvanized, not less than 1.20mm thick modular flush sheet metal enclosure having top, bottom, side and back-wall knockout for conduit entry from any direction, conforming to IS: 14772- 2000 and including modular cover-plates complete all as specified in IS: 732- 1989 and directed for One 20 A single pole and neutral enclosure with a two pin and earth plug and socket, independent, with cables 4.0 mm² size., complete all as specified & directed by Engineer-in-Charge.NOTE: Circuit wire from DB to switch boards shall be included in quoted rate. |
| 112 | Material & Labour for Sub main wiring with two runs of 4.0 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part- I including conduit accessories like bends, tees, junction boxes etc., including 4.0 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire fixed, complete all as specified & directed by Engineer-in-Charge. |
| 113 | Supply and fixing sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with 200 A bus bar, complete all as specified & directed by Engineer-in-Charge. |
| 114 | Supply & Fixing MCB three pole 415 Volts 63 Amps, 10 KA \"C\" curve, complete all as specified & directed by Engineer-in-Charge. |
| 115 | Supply & Fixing MCB single pole 240 Volts 6 to 32 Amps, 10 KA \"C\" curve, complete all as specified & directed by Engineer-in-Charge. |
| 116 | Supply & Fixing MCB single pole & natural 240 Volts 6 to 32 Amps, 10 KA \"C\" curve, complete all as specified & directed by Engineer-in-Charge. |
| 117 | Supply & Fixing LED light fitting Mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor, complete all as specified & directed by Engineer-in-Charge. |
| 118 | Supply and fixing Energy efficient recess mounted LED panel fitting 36 Watt suitable for 2\" x 2\" grid in white colour lumen not less than 120 lmn per watt, total lumen flux 4200 lmn, input voltage 220 to 240 V, power factor should be 90 with high quality diffuser for uniform light & high Efficiency made from CRCA sheet, pre-coated white colour separate replaceable electronic driver, lumen constant of 6500K colour temperature with current electronic connections, complete all as specified & directed by Engineer-in-Charge. |
| 119 | Supply & Fixing LED light fitting 1X9W/1x10 W bulk head luminaries including LED light driver holder connection up with three core flexible copper conductor of suitable size, complete all as specified & directed by Engineer-in-Charge. |
| 120 | Material & Labour for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, complete all as specified & directed by Engineer-in-Charge. |
| 121 | Supply & Fixing ceiling fan 1200mm sweep, heavy duty, single phase, AC, 230 volts, 50 Hz, BEE 5 star rating, ISI Marked complete with down rod, canopy, blades, BLDC motor etc including electrical connections from ceiling rose to fan with 3 core 1.5 sqmm multi stranded copper conductor cable & writing MES No. with synthetic enamel paint, complete all as specified & directed by Engineer-in-Charge. |
| 122 | Supply & Fixing energy efficient exhaust fan of 250mm sweep made of metal body ventilator Air - DS type complete with louver with bolts nuts and washers size of the bots 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base, complete all as specified & directed by Engineer-in-Charge. |
| 123 | Supply and laying of XLPEinsulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor ofsize 50 Sqmm 3.5 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc., all connections., complete all as specified & directed by Engineer-in-Charge. |
| 124 | Supply and Laying of OD 63/50mm Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor, complete all as specified & directed by Engineer-in-Charge. |
| 125 | Supplying and laying of CPVC pipes of size 50mm SDR 11 & Plain CPVC SDR 11 fittings in trenches, complete all as specified & directed by Engineer-in-Charge. |
| 126 | Supply & fixing CPVC ball valve of size 50mm, complete all as specified & directed by Engineer-in-Charge. |
| 127 | Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi stranded copper conductor PVC insulated, unsheathed, FR-LSH ( Flame Retardant Low Smoke & Halogen) Cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc., complete all as specified and directed by Engineer-in-Charge. |
| 128 | Supply and fixing flame proof rotary switch (isolator ) rating 16 Amps. Single pole ON/OFF in aluminium alloy lm 6 construction with one/two nos, 3/4\" ET entries certified by CMRS, Dhanbad for Group I, IIA, IIB, complete all as specified and directed by Engineer-in-Charge.Make:- Sudhir Cat No RI/OA/1010-2A or equivalent of make mention in Appx B |
| 129 | Supply & Fixing flameproof, weather proof LED tube light fitting, type FLP-WP with LED 1 x 16 W including integral reflector made of aluminium alloy LM79, with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type, complete all as specified and directed by Engineer-in-Charge.Make: Crompton Cat No EXTN1LT8-16/20 or equivalent of make mention in Appx B |
| 130 | Supply and fixing flame proofand weather proof industrial type DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB SPN 16 Amps, C type (incoming) (b) 6 Nos MCB SP 10 Amps C type including necessary connection, complete all as specified and directed by Engineer-in-Charge.Make:- Sudhir Cat No MCDB/186 or equivalent of make mention in Appx B |
| 131 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable of size 1.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified and directed by Engineer-in-Charge.Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 132 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified and directed by Engineer-in-Charge.Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 133 | Supply and fixing flame proof and weather proof metal clad single pole and neutral with earth enclosure industrial plug and socket with suitable size of MCB SP 6 to 32 Amps C type, in aluminium alloy LM 6 Construction, certified by CMRS, Dhanbad for Group I, IIA, IIB, including necessary connection, complete all as specified and directed by Engineer-in-Charge. |