| 1 | Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof including taking out of brick layer and sand from trenches completeallas specified and as directed by EIC. |
| 2 | Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind ofsoil complete all as specified and as directed by EIC.. |
| 3 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm insoft/loosesoil. complete all as specified and as directed EIC. |
| 4 | Removing excavated material/soil to a distance not exceeding 50mand depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed EIC. |
| 5 | Supply and fixing Double wall Corrugated High Density Polymer Ethylene (HDPE) pipe of 50 mm sizes as per IS 14930 (Part-2):2001, Laid in trenches/floors and fixed on walls/poles, with and including neccessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed by EIC. |
| 6 | All as above itemNo 5but size of HDPE pipe of size 90 mm diameter |
| 7 | Supply, laying and testingLTXLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable of size 16 Sq mm 2 core with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of following sizes complete all as specified and as directed by EIC.Note:- 1. Excavation and earth work,pipes, clamps, and cable joint shall be measured and paid separetely under respective items :- |
| 8 | All as per item No 7 above but of size 16 Sq mm 4 core |
| 9 | All as per item No 7 above but of size 25 Sq mm 4 core |
| 10 | All as per item No 7 above but of size70 Sq mm 3.5 core |
| 11 | All as per item No 7 above but of size95 Sq mm 3.5 core |
| 12 | All as per item No 7 above but of size 120 Sq mm 3.5 core |
| 13 | All as per item No 7 above but of size 185 Sq mm 3.5 core |
| 14 | Supply & laying in repair 40mm bore galvanized steel tubing \"light grade\"with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified& as directed by EIC. . |
| 15 | All as per ser item No 14 above but of size50 mm bore |
| 16 | All as per ser item No 14 above but of size 80 mm bore |
| 17 | All as per ser item No 14 above but of size 100 mm bore |
| 18 | Road cutting for UG cable under road/railway crossing, pavement, hardstanding by mannually means, protection GI pipe for cable of required dai and making it good to match with the adjoining surface/structure for after cable passing complete all as specified and directed by EIC. Note : GI pipe and PCC will be measured and paid against respective items. |
| 19 | M&L for tesitng of faulty LT XLPE/PVC armouredcable of any size and any position at CAD Pulgaon by using LTvoltage testing kit installed on movable vehicle complete all as specified and directed by EIC.Note : This job includes cost of vehicle transport from Nagpur to Pulgaon and back |
| 20 | Supply & Fixing in repair6 -16 Sqmm 4 Core cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 and 4core XLPE armoured aluminium conductor cable complete all as specified anddirected by Engr-in-Chrage..Make 3M-Seal/Birla/Denson Note : Excavation, returning filling and removelshall be measured and paid separatly under relevant item of this BOQ |
| 21 | All as per item No 20 above but of size 70 to 120 sq mm 3.5 core |
| 22 | All as per item No 20 above but of size 150 to 185sq mm 3.5 core |
| 23 | All as per item No 20 above but of size 240 to 300sq mm 3.5 core |
| 24 | Dismantling and taking out the existing unserviceable (damaged/broken) or serviceable tiltedPanel of any type and anysize, from Locationand removal from site all as directed by Engr-in-Chrage. |
| 25 | PCC (1:2:4) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work allas speciifed and directed by Engr-in-Chrage. |
| 26 | PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work allas speciifed and directed by Engr-in-Chrage. |
| 27 | Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete allas speciifed and directed by Engr-in-Chrage. |
| 28 | Material and Labour for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layerscomplete allas speciifed and directed by Engr-in-Chrage. |
| 29 | Supply install, testing and commissioningOutdoor,in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out ofouter cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet ofsuitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, andfixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of followingall as specified and directed by EIC.Note: In Case of failure, manual system should also be provided. Note :- PCC work will be included in quoted rates and all MCCB and MCB make should be Schneider. Note : The panel manufacturer should have following Govt. Approved Certificates: Make of Panel: Adlec/ Schneider / Universal Switch Gear Control/ Tricolite/ ELECTRO CONTROL SYSTEMS INDIA PVT. LTD (Location : APS School)1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54(IS/IEC : 61439 (Part-1), 2011& IS/IEC : 61439 (Part-2) 2011)2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V5. ISO 9001 CERTIFIED (I) Incoming :-(i) Aluminium busbar, 4 Pole, 400 Amps (ii) Digital Energy Meter 3 Phase CT Operated -01 Make : L&T (iii) MCCB 4P, 350A, 36 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 No. Make : Schneider (iv)Ammeter Digital type, CT operated 0-630A range, MAKE: SECURE / L&T (with selector switch and CT) - 01 Set (v)Volt Meter Digital type 0-500 V range, Make:SECURE / L&T(With selector switch) - 01 No. (vi )SamrtIndicating Lamp LED type 240 V 50 HZ AC supply (Cat Part No : SZRILXX24240 Shakti or euivalent BCH/SIEMENS/L&T) set of three colour (RYB)-01 set. (II) Outgoing :- (i) MCCB 4P, 250A, 36 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. Make : Schneider (ii) MCCB 4P, 125A, 36 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. Make : Schneider(iii) MCCB 4P, 100A, 25 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. Make : Schneider (iv) MCB 3P, 63A, 10 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. Make : Schneider |
| 30 | Supply install, testing and commissioningOutdoor,in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out ofouter cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet ofsuitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, andfixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of followingall as specified and directed by EIC. Note: In Case of failure, manual system should also be provided. Note :- PCC work will be included in quoted rates and all MCCB and MCB make should be Schneider. Note : The panel manufacturer should have following Govt. Approved Certificates: Make of Panel: Adlec/ Schneider / Universal Switch Gear Control/ Tricolite/ ELECTRO CONTROL SYSTEMS INDIA PVT. LTD ( Location : SP Camp)1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54(IS/IEC : 61439 (Part-1), 2011& IS/IEC : 61439 (Part-2) 2011)2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V5. ISO 9001 CERTIFIED (I) Incoming :- (i) Aluminium busbar, 4 Pole, 300 Amps (ii) MCCB 4P, 350A, 36 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 No. (iii)Ammeter Digital type, CT operated 0-630A range, MAKE: SECURE / L&T (with selector switch and CT) - 01 Set (iv)Volt Meter Digital type 0-500 V range, Make:SECURE / L&T(With selector switch) - 01 No. (iv ) SamrtIndicating Lamp LED type 240 V 50 HZ AC supply (Cat Part No : SZRILXX24240 Shakti or euivalent BCH/SIEMENS/L&T) set of three colour (RYB)-01 set.(II) Outgoing :- (i) MCCB 4P, 250A, 36 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. Make : Schneider (ii) MCCB 4P, 125A, 36 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 02 Nos. Make : Schneider (iii) MCCB 4P, 100A, 25 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 02 Nos. Make : Schneider (iv) MCB 3P, 63A, 10 KA, with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. Make : Schneider (v) MCB TPN, 32A, 10 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 02 Nos. Make : Schneider |
| 31 | Supply install, testing and commissioningOutdoor,in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out ofouter cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet ofsuitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, andfixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of followingall as specified and directed by EIC. Note: In Case of failure, manual system should also be provided Note :- PCC work will be included in quoted rates and all MCCB and MCB make should be Schneider. Note : The panel manufacturer should have following Govt. Approved Certificates: Make of Panel: Adlec/ Schneider / Universal Switch Gear Control/ Tricolite/ ELECTRO CONTROL SYSTEMS INDIA PVT. LTD.. (Location : PEPTA)1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54(IS/IEC : 61439 (Part-1), 2011& IS/IEC : 61439 (Part-2) 2011)2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V5. ISO 9001 CERTIFIED (I) Incoming :- (i) Aluminium busbar, 4 Pole, 200 Amps (ii) On Load Change over100A, 415V= 01 No. (iii) Incomming MCCB 4P, 125A, 36 KA,with Integrated Earth Leakage Protection and thermal magnetic: O/L & S/CprotectionICS= 100% ICU= 01 No. (iv) Digital Multifunction Meter :-Voltage, current, PF, kWh, frequency MAKE: SECURE / L&T- 01 Set (v) SPD (Type 2) 3-phase, 20-40kA) - 01 No. (vi )SamrtIndicating Lamp LED type 240 V 50 HZ AC supply (Cat Part No : SZRILXX24240 Shakti or euivalent BCH/SIEMENS/L&T) set of three colour (RYB)-01 set. (vii) Street Light Timer single phase -01 Nos(II) Outgoing :- (i) MCB 3P, 100A, 25 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos.Make : Schneider (ii) MCB TPN, 63A, 10 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos.Make : Schneider (iii) MCB DP, 32A, 10 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. Make : Schneider |
| 32 | Material and labour in replacement/repair for earthing complete with UL listed CPRI Tested maintenance free copper bonded earth rod of 3.048 metres having diameter of 17.2mm with 254 micron copper coating with clamp made of Plastic (PPGF) of outer dimension 290(L) x 290(W) x 209(H) withstand load of 60kN.buried directly in ground vertically to a depth below normal ground levelMeets the requirement for IS/IEC 62305 and IEC 62561-5 CAPE Type: EC 290 (Article No. 300 852)stainless steel for terminating cable / flat conductor. Earth enhancing mineral (PROCEN) compound ( electrical resistivity 0.018 ohm metre ) 25 kg tested for Leaching & TCLP with NABL accredited lab. The systems is conforming to IS 3043, IS / IEC 62305, IEC 61643-5-54, UL 467, the rod has to be tested to for dimension, marking, tensile strength, salt mist, coating thickness, electrical resistivity test before and after corrosion test etc as per IEC 62561-2.Chamber Inspection Pit made up of PP material can bear 60kN(6000KG) load. Set Consist of following BOM (1) Earth rod of 3 mtr length having the dia of 17.2 mm dia (CAPE Type No. CBR 1710 (Article No - 300 060) (2) CAPE Type: PROCEM 12.5 (Article: 300 790 ) , 12.5 Kg bag x 2 nos (3) CAPE Type : Universal SS Clamp SSUC 17( Article No 300580 ) (4) Earth Pit Chember 290(L) x 290(W) x 209(H) Fixing of Earth Chamber Inspection Pit made up of Plastic (PPGF) of outer dimension 290(L) x 290(W) x209(H) withstand load of 60kN. Meets the requirementfor IS/IEC 62305 and IEC 62561-5 CAPE Type: EC 290 (Article No. 300 852) including earth work complete all as specified and directed by EIC. Note :- Earth strip 32x6 mm up to 7.5 mtr shall be included in quoted rate.Make : CAPE |
| 33 | S&F for copper earthing strip 32x6 mm with nut and bolts complete including taking down old one allas specified and directed by Engr-In Charge |
| 34 | S and F in repair of redium tape 7Cm width ordinace colour (Sky Blue 2 Round and Red one round) withsub depot colour one round wrapping around the poleincluding taking down old one complete all as specified and as directed by EIC. |
| 35 | S & F Junction Box (Pole-mounted) Outdoor, Weatherproof, IP65 rated, Rust-proof FRP/Polycarbonate enclosure, size ~ 300mm x 200mm x 150mm, hinged door with lock Busbar Strip (Aluminium )TPN (Three Phase + Neutral), Aluminium flat bar, 25 mm x 3 mm, mounted on insulated supports 4 Nos. (R, Y, B, N) Busbar Support Insulator Porcelain / Epoxy type, suitable for 440V LT distribution 8 Nos.Miniature Circuit Breaker (MCB) 10A, Single Pole, 240V AC, C-curve, IS/IEC 60898Incoming & Outgoing Cable PVC insulated, FRLS, copper/aluminium conductor, 1C x 16 sq.mm (approx.), color coded (R, Y, B, N, Earth)Cable Glands Brass / Polyamide, weatherproof, suitable for 16 sq.mm cable 4 Nos.Lugs / Thimbles Aluminium heavy-duty crimping type, ISI marked 8 Nos.Fasteners & Hardware SS bolts, washers, screws for busbar and box mounting Lot Wiring Accessories Ferrules, PVC sleeves, insulation tape etc.including taking down old one complete all as specified and as directed by EIC. |
| 36 | supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures andconventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size |
| 37 | supply and fixing in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade. |
| 38 | M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm diainsulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed by EIC. |
| 39 | Trimming and cutting of tree branches(not more than 50 mm girth) coming acrossLT over head line clearing the line around 2m single/both sides andand disposal of branchesfrom siteexeeding 50m and not exceeding 250m from site complete allas directed by Engr-in-Charge.Note : - (i) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole.In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible.(ii)All Safetytolabourer must be adhered by the contractor during trimming and cutting of tree branches. |
| 40 | Taking down rusted anticlimbing device and providing new anticlimbing device spikes typefabricated out of MS bars (round/square/flat) including nuts, bolts, washers and welding into halves made to shape to suit the cross section of steel/RCC poles including galvanized steel 2- strand barbed wire wiith 2.00mm dia barbs wrapped spirallly to round pole to a length 0.5 to 1.0 mtr clamped and properly secured or as ordered all as specified and directed.by EIC |
| 41 | S&F in repair of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6. CAPE Type No: PRO LER (Article No. 400 999)all as specified and directed.by EIC. Make : CAPE |
| 42 | Supply and fixing and Testingin repire ofSurge Protection Device Type 1+2 Tested as per IEC 61643 Part 11:2011with following specification:Nominal voltage -230V 50/60Hz and MCOV ≥ 300 V ,The Surge Protection Devices shall have TOV withstand(L-N/N-PE) ≥ 440 V for 120 min/1200 V for 200 ms.Lightning Impulse discharge current (L-N/N-PE) -12.5 kA/50 kA (10/350µ sec),Nominal Discharge current (L-N/N-PE) - 20 kA/50 kA (8/20µ sec & Max Discharge current (L-N/N-PE) - 65 kA/100 kA (8/20µ sec).Protective Elements are High Energy MOV & GDTand the Protection Modes for : 3 numbers of Type 1 + 2 SPD for connection between Phase and Neutral and one number of SPD between Neutral and Earth. Leakage Current not allowed Short- Circuit Current rating (Isccr) – 50 kA . Back up fuse shall be 315 AgG/gL. Health Status Indication required in all catridge including N to PE and Remote monitoring facility.Total Response time(L-N/N-PE) < 100ns. all as specified and directed by EIC. Make : CAPE |
| 43 | Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz doublepole 100 Amp all as specified and directed by EIC. |