| 1 | Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole/stay, or cable trenches etc and getting out in soft/loose soil, complete all as specified and directed. |
| 2 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 3 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. |
| 4 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm outer dia conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 5 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50mm outer dia conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 6 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core including taking down old unserviceable UG cable of any crossection including bricks, GI pipes etc of any description, laid in trenches or fixed with walls/poles, complete all as specified and directed.Note :- Excavation and earth work shall be measured and paid seperately) |
| 7 | All as per item No 6.00 here-in before but size 25 Sqmm, 3.5 core, complete all as specified and directed. |
| 8 | All as per item No 6.00 here-in before but size 35 Sqmm, 3.5 core, complete all as specified and directed. |
| 9 | All as per item No 6.00 here-in before but size 50 Sqmm, 3.5 core, complete all as specified and directed. |
| 10 | S&F GI tubing 40mm bore (light grade) with all fittings for protection of cables, laid in trenches including making good to the distrurbed surface,complete all as specified and directed (Note : Excavation and earth work shall be measured and paid separately) |
| 11 | M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0cm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanisedmeans of earth wire 4mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe, light grade, 20mm bore and watering pipe GI, medium grade, 15mm bore and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC (1:3:6) type C-2 all as shown in electrical plate No-3 of SSR part-I (2009) connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion including demolition of old unserviceable earthing of any description, complete all as specified and directed.Note : (i) Proper earthing pit should be provided with pit cover.(ii) GI earth wire upto pole/panel/DB shall deemed to be included in the unit quoted rate. |
| 12 | Horizontal boring under the road (with manual method) below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed. |
| 13 | Supply, fabricating, installing, testing and commissioning of outdoor type LT bus bar box, factory made, of size not less than 900mm (L) x 900mm (B) x 450mm (D) factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounted on 40 x 40 x 5mm angle iron supports at the base duly painted with synthetic enamel paint (spray painting) over and including priming coat and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply, including suitable size cable glands, lugs etc, in proper arrangement for ventilation, including taking down of old unserviceable bus bar box, complete all as specified and directed |
| 14 | S&F LED flood light 120 watt, 230 V, AC, outdoor type, with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant made out of pressure dia cast aluminium housing with toughened glass and high power LED and secondary lenses, system efficiency > 110 LPM and 10 KV SPD included with driver and lamp complete with polycarbonate junction box and connecting wire copper 2.5 Sqmm, 3 core including taking down old unserviceable flood light, complete all as specified and directed. |
| 15 | All as per item No 14.00 here-in before but 150 watt, complete all as specified and directed. |
| 16 | All as per item No 14.00 here-in before but 200 watt, complete all as specified and directed. |
| 17 | All as per item No 14.00 here-in before but 250 watt, complete all as specified and directed. |
| 18 | Supply and fixing post top lantern LED type 60 watt, 230 volts, AC, outdoor type with thermal management in multiple optics and equipped with IP 65 protection with impact and corrosion resistant made out of pressure dia cast aluminium housing with toughened glass and high power LED and secondary lenses, complete with driver and lamp complete with polycarbonate junction box and connecting wire copper 2.5 Sqmm, 3 core upto junction box, complete all as specified and directed. |
| 19 | Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor (FRLSH) cable 1100 Volt grade, drawn through and including PVC concealed conduit heavy duty, and accessories of not less than 25mm dia, ISI marked, including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 6.0 sqmm single core PVC insulated unsheathed copper earth continuity conductor (FRLSH) type, including making good disturbed surface as per existing surface including taking down existing sub-main wiring, any numbers of wire and any size, complete all as specified and directed.Note: Two runs of single core cable with one run of earth continuity conductor including PVC conduit & accessories shall be measured and paid as one length. |
| 20 | Supply and draw sub main wiring in repairs of two run 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor (FRLSH) cable 1100 Volt grade, drawn through and including PVC concealed conduit heavy duty, and accessories of not less than 25mm dia, ISI marked, including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 4.0 sqmm single core PVC insulated unsheathed copper earth continuity conductor (FRLSH) type, including making good disturbed surface as per existing surface including taking down existing sub-main wiring, any numbers of wire and any size, complete all as specified and directed.Note:Two runs of single core cable with one run of earth continuity conductor including PVC conduit & accessories shall be measured and paid as one length. |
| 21 | M&L for removing flashed carbon from distribution box/LT panels of any type and size, cleaning with cleaning agent properly and replacement of burnt out parts like spreader link, bottle lugs of suitable size etc, complete all as specified and directed.(Note : Cost of parts shall deemed to be included in the unit quoted rate.) |
| 22 | S&F in replacement offirst aid kit box/emergency medical boxwall mouted type made out of powder coated GI sheet of 18 gauge and the size of the box will be 36cm(H) x 26cm(W) x 13 cm(D) with front transparent acrylic glass and multi compartment 4 shelf for better organize of medicines with security lock on door, openable window at front side with help of hinge at one side and locking arrangement at another side, openable window must painted with \"FIRST AID\" with red paint and whole box will fixed on wall at height not less than 2mtr including medicene and other items as under :- (i) Sterilized dressings- 04 Nos, (ii) Cotton Wool 10 gm - 02 Nos, (iii) Antiseptic Solution (100 ml) - 01 No, (iv) Burn Ointment - 01 No, (v) Scissor - 01 No, (vi) Digital Thermometer - 01 No, (vii) Disposal Gloves - 02 Nos, (viii) Disposal Mask - 20 Nos, (ix) Adhesive / Microporous Tape 1/2\" - 01 No, (x) Band- Aid - 10 Nos, (xi) Safety pins - 05 No, (xii) Cold Rub - 01 No, (xiii) Roller Bandage (5cm) - 02 Nos, (xiv) Roller Bandage 10 cm - 02 Nos, (xv) Cotton Buds - 10 Nos, (xvi) Hand Sanitizer - 02 Nos, (xvii) Handiplast - 12 Nos, (xviii) Antiseptic cream - 01 No, (xix) Antiallergic medicene, Cough medicene, Pain killer, Fever and cold medicene- 01 strip each and a First-Aid Guide booklet, complete all as specified and directed. |
| 23 | Uprooting grass/weeds/plants up to 30cm depth by scrapping soil inorder to make free ground from all sort of vegetation and hand packing carefully by packing round pebbles approximately of size 20 to 40mm after carefully picking form heap of pebbles/stones, complete all as specified and directed. |
| 24 | M & L for cleaning of vegetaion including spray chemicals for prevention of growth of weed and grass at E/M sub station area with spray gun as per the manufacturer\"s instructions, complete all as specified and directed |
| 25 | Supply and spreading unslaked lime at surrounding (avarage 300 gms per Sqm), complete all as specified and directed. |
| 26 | Supply and filling dry river sand at surrounding of E/M installations / sub stations /cable trenches including watering and consolidation, complete all as specified and directed. |
| 27 | Supply and filling dry crushed stone aggregate, free from any foreign particles, 25mm gradded, for spreading at E/M sub station area, complete all as specified and directed. |
| 28 | Demolition of brick work or stone masonry, built in CM including all quoins, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles , complete all as specified and directed. |
| 29 | M&L for brick work with flyash bricks, old size, straight or curved on plan exc 6 mtr mean radius built in CM (1:6), complete all as specified |
| 30 | All as per item No. 29.00 here-in-before but except bricks, complete all as specified and directed.Note : (i) Bricks obtained from demolition shall be re-used.(ii) The quoted rate shall deemed to be included for cleaning of old bricks obtained from demolition. |
| 31 | M&L 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement, complete all as specified and directed. |
| 32 | M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed. |
| 33 | M&L for preparing old steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality), complete all as specified and directed. |
| 34 | Demolition of unreinforced cement concrete in ground floors and paving n. exc. 15cm thickness (below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed. |
| 35 | M&L for PCC (1:2:4), type B-1. (using 20mm graded crushed stone aggregate) as in benching. coping, bed plate, lintel, benching etc. including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed. |
| 36 | M & L 75mm thick PCC (1:3:6), type C-2, (using 40mm graded crushed stone aggregate) as in path/hard standing, drain sides, plinth protections etc.finishing cementconcrete surface even and smooth without using extra cement , complete all as specified and directed. |
| 37 | S&F LED building security light fittings 30 Watt 230 Volt, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket, impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old unserviceable building security light fittings of any capacity, complete all as specified and directed |
| 38 | M & L for mild steel chequired plates Fe-290 (Grade E-165), 5mm or over in thickness conforming to IS1730-1961 as in duct covering placed over existing angle iron frame work or provision new frame work where necessary including connection of suitable number earth strip, welded properly and making good to the existing surface of duct including taking down old damaged chequired plate, complete all as specified and directed |
| 39 | Taking down unserviceable high mast light fitting of any wattage from poles/walls/height, repair the same in site by opening cover, replace unserviceable parts like LED driver, stainless steel wire, holder, capacitor etc, and unserviceable burnt cable etc, as required at site, and re-fixing the same after repairing work, at the existing position, complete all as specified and as directed.Note : Spare parts required for replacement shall be paid as \"supply only\" under relevant items. |
| 40 | M&L for opening and carrying out repair to gear mechanism, mounted on shaft of 1 HP motor of high mast, after dismantling the assembly complete, replacement of wornt out spares such as gear tooth profile, gear shaft, sleeves, brushes etc, including filling, turning & polishing works to gear shaft, as necessitated, reassembling the gear moving mechanism after repairs and testing, complete all as specified and directed. |
| 41 | S&F bearing and bush with key and bushes suitable for 1 HP motors, complete all as specified and directed. |
| 42 | Repair to squirrel cage induction motor shaft by welding/grinding, polishing to required sizes for motors of capacity 1 HP, complete all as specified and directed. |
| 43 | Supply, hanging stainless steel wire of 6/8mm dia for holding the high mast light/lantern carriage, with necessary locking and fixing arrangement, complete all as specified and directed. |
| 44 | M & L for servicing of up-down function of High mast light including greesing, oiling, replacement of minor parts, including replacement of control wiring for electric auto up-down function etc, complete all as specifed and directed |
| 45 | S&F astronomical time switch in existing street light timer panel for switching on/off lights and other electric devices according to the sunrise/sunset times, based on the entered location or location coordinates including taking down old unserviceable time switch, complete all as specified and directed. |
| 46 | S&F DC 12 volt, white, LED module IP 68 (20module, 60 LEDs), super brightness LED module having 20 modules, 20 volts DC input per string length 10 ft, complete all as specified and directed. |
| 47 | S&F LED strip driver 12 volt, 16 Amp, 120 watt AC to DC switching adopter converter driver, compatible for AC input supply 230 volt, complete all as specified and directed. |
| 48 | S&F in repairs PVC insulated & sheathed stranded copper (FR) cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including suitable size copper luggs, complete all as specified and as directed. |
| 49 | S&F in repairs PVC insulated & sheathed stranded copper (FR) cable 3 core of cross sectional area 2.5 Sqmm for providing necessary electrical connection from junction box to light fittings including suitable size copper lugs, complete all as specified and as directed. |
| 50 | M&L for earthing & testing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including earth lead GI strip 25 x 3mm by means of bolts, nuts and check nuts and washers etc, made of GI & connected to earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt I including all necessary earth work, excavation, PCC chamber, (1:2:4) B1 & RCC (1:2:4) B1 chamber cover with suitable reinforcement with handle including 40mm bore GI light grade protection pipe upto 7.5m length & 20mm bore GI medium grade watering pipeand wire mesh, funnel, char coal dust, common salt, wire mesh etc. including taking down unserviceable earthing of any description, complete all as specified and directed. Note : (i) Proper earthing pit should be provided with pit cover.(ii) GI earth strip upto 7.5m is demed included in the unit quoted rate. |
| 51 | Supply, installation, testing and commissioning of out door type, LT panel made out of3.15mm thick CRCA sheet, CPRI approved manufacture, totally enclosed weather dust and vermin proof, as per IS, with front and rearopening, double door and suitable locking arrangement having copper bus bar suitable size, for RYB including rust free spray painting with two coats of sytnthetic enamel paint (1st grade quality) over a red oxide primer and neutral and insulated with insulators,including connecting incoming and outgoing cables including necessary foundation in PCC (1:3:6) type C-2 and 50 x 50 x 6mm angle iron grouted in PCC foundation, above 30cm from ground level comprising the following, complete all as specified and directed:-Incoming:-(a) Aluminium bus bar chamber (04 strips), 3 phase, 415 volts, 100 Amp fixed on insulators at required interval, the bus bar shall be colour coded (red, yellow & blue) for 3 phase and black for neutral.(ii) MCCB, 40 Amp, 4 pole, 415 volts 16 KA with thermal magnetic protection - 01 No.Outgoing :(i) MCB TPN \"C\" curve, 16 Amp - 01 No.(ii) MCB SP\"C\" curve 16 Amps - 01 No.(iii) Auto/manual switch - 01 No.(iv) Up & down push bottom for lowering & raising of high mast bracket assembly - 01 No.(v) Reverse & forward DOL starter for 2 HP motor -01 No.(vi) Electro programmable Astro timer with photo sensor- 01 No.(vii) Contractor 4 pole 40 Amp - 01 No.(viii) Digital multi function meter showing volts, Amps PF and Hz - 01 No.(ix) LED Indicating lamp (RYB) with selector switch -01 Set. |
| 52 | S&F LED type integral aviation obstruction light (Heavy duty) IP 65/66, single light fitting comprising of Die-cast aluminum housing with Red polycarbonate dome for better illumination, integral driver, Supper flux 5mm 302nos LEDs incorporated, powder coated aluminium housing with polycarbonate enclosure including taking down unserviceable aviation light fittings, complete al as specified and directed. |
| 53 | Taking out existing unserviceable/defective light fitting / high bay light fitting of any wattage from poles/walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of and checking out the defects, trace out damage/unserviceable parts like driver, wire, led lamp etc. and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing, complete all as specified and as directed.Note :- (i) Any minor item like nuts, bolts, clamps, washers and wires for connection required to make the fitting serviceable shall deemed to be included in the unit quoted rate. (ii) Defective parts replaced shall be paid as \"supply only\" under relevant items. |
| 54 | Supply only OEM LED driver suitable for 30 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 55 | Supply only OEM LED driver suitable for 45-50 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 56 | Supply only OEM LED driver suitable for 60 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 57 | Supply only OEM LED driver suitable for 72-80 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 58 | Supply only OEM LED driver suitable for 120-150 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 59 | Supply only OEM LED driver suitable for 180-200 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 60 | S&F in replacement of contactor TP, 50 Amp, complete all as specified and directed. |
| 61 | Note: An amount of Rs.54,410.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 62 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |