| 1 | S/E of S.T pole 410 SP-62 including excavation and back filling with plinth in 1:3:6 cement concrete etc. all comp. (P.S.R.) |
| 2 | S/F of double arm bracket as per direction of E/I |
| 3 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.(PWD SOR Item No 641/2018). |
| 4 | Painting of electric pole with two coats of aluminum paint over red oxide comp. in all respect (PWD SOR Item No 634/2018). |
| 5 | S/E of Double walled corrugated HDPE pipe size 90/63 mm at a depth of 1.20 mtr. Below ground level complete excavation and back filling (Rate includes manual trunch less if required) complete work as per direction of E/I. |
| 6 | S/F og G.1. pipe 40 mm dia \"B\" class for climbing up the cable from ground to overe head line (P.S.R.) |
| 7 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (PWD SOR Item NO 501/ 2018)- 25 Sq.mm. x3-1/2 core 501(J)/2018 |
| 8 | S/F of palm or pin type copper tinplanted cable socket (lug) to the cable leads etc. comp. (504/2018)25 Sq.mm. x3-1/2 core 501(e)/2018 |
| 9 | S/W of submain with two number 4 sq.mm. PVC insulated 1100 V grade single core copper conductor cable in 20 mm dia. heavy guage rigid steel conduit on surface, with one number 8 SWG GI earth continuity wire etc, complete in allrespects{289(A) SOR-2018} |
| 10 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 807(PWD)SOR-2018(F)(ii) 40 A TPN |
| 11 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 Watt. Confirming to IP 66 Protection complete in all respect. E/I S.I 1480(2018)CAT-AAA(Make - Halonix, Philips) |
| 12 | S&F of junction box with provision of bus bar, kit-kat etc. required as per site complete in all respect. |
| 13 | S & F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve S.I.no. 1002(CATA)/2018 |
| 14 | S/b of earthing rod 20 mm dia x 2.5 m long including G.I. wire 7/16 s.w.g. to connected earth rod & earth clamp on pole 3m long steel conduit carry earth wire along pole comp. in all respect (P.S.R.) |
| 15 | fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 watt complete in all respect. (PWD SOR Item NO1424(A) CAT-AAA/2018) (Labour rate only) |