GENERAL-2361958/2025-Electrification to Park in Perumpadapu, Division 18, Kochi Municipal Corporation -General Electrical Work-- 1 SITC OF STREET LIGHT 2 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters 3 90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 4 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 5 14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. 6 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). 7 OD82352/2025-2026:Reinforcement of RCC work .bend,tied,and and placed in position (plain grill requiring bend cold) using for steel 8 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels 9 OD82348/2025-2026:Earthing with G.I. earth pipe 2 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 10 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 11 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 12 OD82350/2025-2026:Supply and providing out door terminal box 140x140x95mm(GSJB 1414 Sintex make) 13 OD82349/2025-2026:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base 14 OD82346/2025-2026:Supply and providing 12x3mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes 15 OD82347/2025-2026:Supply and providing 25x6mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes 16 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm 17 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size 18 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) 19 OD82351/2025-2026:Supply and providing earth clamp of 12mm thick suitable for 4/6/10 sq mm Cable 20 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 21 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 22 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 23 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 24 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 25 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 26 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 27 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 28 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door 29 OD82378/2025-2026:Supply and fixing Time switch 240 V AC DIN/BASE mounting type and giving connection 30 OD82379/2025-2026:Supply and fixing 40A AC1 MNX 4 pole power contractor (L&T)in the existing enclosure and giving connection 31 OD82393/2025-2026:Supply and providing post top luminaire 25WIP65 protection fixing it on existing GI pole or concrete pillar with GI pipe of suitable size and length welded or concreting ,neatly painted with suitable colour enamel paint over a coat of epoxy primer and giving connection ( Havells 25W Ruby Clear Landscape Lightor Crompton CHAPLET make ) 32 OD82437/2025-2026:Supply and fixing spot light for existing name board fixing it on suitable bracket and giving connection (Havells,Cromption,Philips make) 33 OD82455/2025-2026:Supply andproviding Sintex boxof size 600x500x250mmfor fixing DB,Contactor,Timer,etccomplete (Sintex 6050or equivalent ) 34 OD82456/2025-2026:Supply and installation of dust and Vermin proof wall mounding meter box 350x250x150mm SINTEX make GSMB 3525or equilentwith base plate suitable to fixing1 phase energy meter and cut out 35 OD82517/2025-2026:Supply fabrication conveyance and installation of lamp post 63 mm dia B class GI pipe of 4 M with 12mm thick 150x150mm base plate with 4 nos foundation bolt , nut and washer fixed on RCC foundation of required quantity neatly painted with suitable colour enamel paint over a coat of epoxy primer including providing necessary bracket for fixing flood lights .For fixing LED flood lights in front of open air stage 36 OD82345/2025-2026:Fee to be remitted to KSEB as supervision charges . Amount shall be reimbursed according to the original receipt