Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #51272220

Tender For Construction Of 1 Ranney Well, 1 Mbs And Laying The Rising Main Line For Iihm Ganaur District Sonipat. “Construction Ofranney Well And Mbs Including Clear Water Tank, Boundary Wall, C/W Suction Well,Pump Chamber, Pumping Machinery, Electric T

Issued by Government Departments · ganaur, Haryana
Tender Value
21.57 Crore
Estimated cost
Bid Submission
08 Oct 2025
0 days left
EMD
43.15 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ganaur → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

CONSTRUCTION OF 1 RANNEY WELL, 1 MBS AND LAYING THE RISING MAIN LINE FOR IIHM GANAUR DISTRICT SONIPAT. “Construction ofRanney well and MBS including Clear water Tank, Boundary wall, C/W suction well,Pump chamber, pumping machinery, electric transformers and D.G sets, Gas chlorination, road and path,Automation system, H.T metering panel room. Guard room, Staff quarters and Laying the Rising main lines at IIHM Ganaur. Operation and Maintenance during defect liability period of 12 months after successful completion of 3 Months trial run and thereafter for 5 years complete in all respect

BOQ

IIHM GANAUR : CONSTRUCTION OF 1 RANNEY WELL, 1 MBS AND LAYING THE RISING MAIN LINE FOR IIHM GANAUR DISTRICT SONIPAT. “Construction ofRanney well and MBS including Clear water Tank, Boundary wall, C/W suction well,Pump chamber, pumping machinery, electric transformers and D.G sets, Gas chlorination, road and path,Automation system, H.T metering panel room. Guard room, Staff quarters and Laying the Rising main lines at IIHM Ganaur. Operation and Maintenance during defect liability period of 12 months after successful completion of 3 Months trial run and thereafter for 5 years complete in all respect.”
Sl. No. Item Description
1COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (150 Sqmm size)
2`HT Metering Panel: Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG)a). VCB, 11KV, 630Amp, 50KA.b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s.c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2.d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays.e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above.f). Master trip relay -2 no’s.g). Indicator type Annunciator panel with buzzer.h). Digital Volt Meter- 0-11 KV.i). Digital Amp Meter- 0-100 Amp.j). RYB/ Trip/Closing/Spring charged indicator lamp.k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay.l). TNC Switch for Operation.m). Multifunction Meter EM6400NG.n). TCS Relay for Safe`
3HT. ALLUMINIUM CABLE: Supply erection testing of standard make XLPE 3 core HT / 11 KV grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connectiona) from G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect. Make: Finolex / Havells / RR Cables. (35 Sqmm size)
4LT CABLE ALLUMINIUM: Supply, erection, testing and commissioning of IS marked 3.5 core Cables, Solid Aluminum conductor up to 10sqmm and balance stranded conductor, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Aluminium wire for single core up to 70sqmm and balance Aluminium strip, Glavanised wire for cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip) extruded PVC type ST2 Outer sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with up to date amendments along with all accessories complete in all respect. Make: Finolex / Havells / RR Cables. (300 Sqmm size)
5Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 300 mm nominal diameter
6Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 105 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton redplusgreen with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well.VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor.It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture.Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At MBS near Yamuna River)
7`CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clearwater having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked`8400 LPM x 32.50 M Head (At MBS near Yamuna River)
8`Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications.Size as per site requirement.(IP-68), RS-485 ModBus.Line size 400 mm, installed at pump End / Source. (For MBS) `
9SIM Card: SIM Cards for five year maintenance of all the instrument above as required. ( For MBS)
10`Radar and Water Level Transmitter: Supply, Installation, testing, Commissioning with five year maintenance of Radar and Water Level Transmitter alongwith according to water level in OHSR (for OHSR) Ingress Protection – IP 66, Measuring range – Up to 20 M, Process temp.- -40 to 60 deg. C, Full PVDF Body – For a long sensor lifetime.**Unit Rate given, actual quantity to be ascertained while placing order. (For MBS)`
11`RTU: Functional Integration at RTU-cum-Gateway for Motorized Control Valve in Pump Control Panel(For MBS)`
12`Butterfly Valve: Supply, Installation, testing, Commissioning with five year maintenanceof Butterfly Valve with Electrical Actuator Body Material - CI/DIPressure Rating – PN16 Feedback - 100% Open and 100% close. **Unit Rate given, actual quantity to be ascertained while placing order 400 mm(1 For MBS and 1 for B/Stn. at IIHM campus)`
13`Automation Panel: `Automation Panel for integration with VFD with Pump Control Panel, along with Auto/Manual Selection Switch as well as On/Off push button to be provided. Manual selection between pump 1 and pump 2 depending on which to be operated and which to be stand by to be provided, along with all relay interlocks and provision of operation of pumps through potential free/open collector digital outputs of RTU-cum-Gateway device. The panel will contain RTU-cum-Gateway with necessary I/Os and edge controller Motorized control valve in Local / Remote or Auto/ Manual modes of operation in tandem with Cloud Scheduler or Level sensor-based functions.Panel will contain SMPS with rechargeable battery backup (min. 24 hrs.) along with facility to connect all field instruments with 24 VDC power supply. `(For MBS)`
14`Online Chlorine Sensor : Supply, Installation, Testing, Commissioning with five year maintenanceof Online Chlorine Sensor. (For MBS)`
15`Cloud based software comprising of Middleware, Database and Front-end web interface through suitable Dashboards, Aggregation screens and GIS assisted drill-down from macro to micro to be provided. Application data hosting and maintenance for Five years included in scope. Cloud servicesof Ministry of Electronics and Information Technology (Meity), Government of India empaneled cloud service providers shall be taken like Microsoft, Amazon, Google, BSNL etc. Cloud service provider must adhere the security standards and guidelines issued by Meity from time-to-time.As the data belongs to the State Government of Haryana, therefore the application and data hosted on Cloud must be kept and stored in data centres located in India only. Any change in application requirement or infrastructure shall be borne by the Implementation agency. Implementation agency shall carry out the Application Security Audit from a Certified Auditor (CA). Application and data shall be kept confidential and only the authorized users shall have the access to it.Implementation Agency shall be responsible for any data theft or data leakages.`
16Designing, providing, fixing, testing and commissioning of GASEOUS CHLORINATION SYSTEM having capacity upto 2000 grams/ hrs. as designed having the control of gas upto 20th part of max. dose . The complete system consists of (a) Vacuum regulator (b) Measuring Glass Tube (c ) Ejector (d) PF tubing (e) Spanner with cylinder opening key (f) Ammonia Gas (Liquid for leaking test) (g) 1’ dia PVC pipe with PVC fitting, ball valves etc. (h) 2 Nos. chlorine gas cylinder capacity 100 Kg. duly certified and approved by BIS and Explosive Department Govt. of India (i) Electronic Chlorine gas leak detector with sensor and hooter (j) Full face mask with canister as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070- 23142 dated 28-02-2024
17Designing, providing, fixing, testing and commissioning of CHLORINE GAS DRY SCRUBBER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.
18Designing, providing, fixing, testing and commissioning of AUTO-SHUT OFF VALVE as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
19Designing, providing, fixing, testing and commissioning of ONLINE COLORIMETRIC WATER QUALITY ANALYZER FOR RESIDUAL CHLORINE AND TURBIDITY including RTU-Cum-Gateway with Cellular (GSM, GPRS,4G/L TE,5G, NB-IoT), LoRa or other RF technology for remote data transfer as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
20Designing, providing, fixing, testing and commissioning of VACUUM-OPERATED AUTOMATIC SWITCHOVER SYSTEM WITH ALTERNATE CHLORINATOR as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
21`Design, Construction, Erection and Commissioning of 1 Ranneywell (Radial collector well) of 8.00 MLD capacity with minimum sinking depth of 30 mtr and 1000 mtr long Laterals pipe in 4 layers, all Civil, Mechanical and electrical works including transformer as per design along with all accessories and cables, CubicaI type LT/HT Panels, VCB panels, all types of cablings with cable tray, Chemical Earthings of all machineries, 4 VT Pumps (3W plus 1S) having capacity 169.20 m³/hr. x 35 m head, VFD Panels, M.S Header with all necessary fittings, Gantry as per design, Electromagnetic Flow meters at all outlets and inlets, Field office (4 mtr X 4 mtr with attach Toilet), Horticulture and landscaping (3000 sqm) including purchase of 1.50 acre land (For Ranneywell, MBS and approach path from revenue rasta to well), earth filling in Ranneywell complex.1 High mast street light 12.5 mtr high pole with 8 Luminous lights, wire / cable, switch. MCB and proper foundation etc complete in all respect. 10 CP Plus CCTV HD coloured night vision cameras and 1 360 degree Dome camera fitted at 11 m. high Pole along with proper foundation with HD night vision. PLC/SCADA based Automation and monitoring system. All the pumping machinery, panel board, flow meter, Level sensor etc shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at Ranneywell and MBS site through broadband internet facility.The work will be carried out strictly as per detailed scope of works, specifications, conditions mentioned in the DNIT and entire satisfaction of Engineer-in-charge.
22Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through s set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standers panel, making second incoming cable connection from transformer, outgoing cable connection from changeover/ STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specification and directions of Engineer-in-Charge. The rating should be at 1500 RPM.a) Diesel Engineb) Alternator cc) Battery 24 v.d) Base plate.e) Suitable sq mm suitable core copper cable upto 40 meters.f) Tools, standard panel.g) Metering, set 415 VAC-1 set (Amp. Meter, volt meter, ASS, VSS, phase indicator, control fuse, frequency meter, CT’s)h) Metering set 60/5A//440V (Amp. Meter, volt meter).i) Overload protection for DC-1 No.j) Battery charger 24V DCk) Copper bus bar of suitable sizel) KWH meter 96 sq mm sizem) Starting fuse button and key switch9on/offn) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, DC control and other required accessories complete in all respects to the satisfaction of Engineer-in-Charge’ 7. 160 KVA (As per parameters of CPCB 4)
23Operation and maintenance for the complete scope of work mention in the DNIT for a period of 12 months during defect liability period after 3 months successful trial run period (will be charged to the A/Mtc. Estimate).
24Operation and Maintenance during 1st year after defect liability period.
25Operation and Maintenance during 2nd year after defect liability period.
26Operation and Maintenance during 3rd year after defect liability period.
27Operation and Maintenance during 4th year after defect liability period.
28Operation and Maintenance during 5th year after defect liability period.

AI Tender Summary

OUR REF NO 51272220
AUTHORITY Government Departments
TENDER VALUE 21.57 Crore
LAST DATE 08-10-2025
Authority
Authority Name Public Health Engineering Department
Work Description CONSTRUCTION OF 1 RANNEY WELL, 1 MBS AND LAYING THE RISING MAIN LINE FOR IIHM GANAUR DISTRICT SONIPAT. “Construction ofRanney well and MBS including Clear water Tank, Boundary wall, C/W suction well,Pump chamber, pumping machinery, electric transformers and D.G sets, Gas chlorination, road and path,Automation system, H.T metering panel room. Guard room, Staff quarters and Laying the Rising main lines at IIHM Ganaur. Operation and Maintenance during defect liability period of 12 months after successful completion of 3 Months trial run and thereafter for 5 years complete in all respect
Basic Detail
Tender No 202573EBB284 D475 4C2D 9EDF 91E3CE4599F7587PUH
Bidding Type Tender
Location
City ganaur
State Haryana
Key Dates
Publish Date 17 Sep 2025
Submission Date 08 Oct 2025
Open Date 08 Oct 2025
Finance
Tender Value 21.57 Crore
Tender Fee 20000
EMD 43.15 Lakhs
Exemption Available
Document List
28cac0b8-5c5e-4798-a313-f906282847dc.html
1F4BN0Z133193.pdf
BOQ_550930.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 08, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

28cac0b8-5c5e-4798-a313-f906282847dc.html

pdf

1F4BN0Z133193.pdf

xls

BOQ_550930.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders