| 1 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/ soft soil and getting out for underground cable/ erection of poles, stays, trench etc., complete all as specified and directed. |
| 2 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25cm thick layers, complete all as specified and directed. |
| 3 | Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point, complete all as specified and directed. |
| 4 | Supply, fixing or layingHDPE (DWC) tubing 100 mm dia as per IS:16205 part 24 fixing on poles, walls under floors, laying on surface etc as reqd at site including clamps to hold pipe at position, complete all as specified and directed. Note: All items and accessories , bend, joints, nut bolts, clamps for wall fixing as per site requirement etc are incl in quoted rates. |
| 5 | All as per Srl Item No 4.00 above but for 50mm dia, complete all as specified and directed. |
| 6 | Disconnecting & taking out defective underground cableany size and any type from trenches, pole, pipe, floor, wall etccomplete all as specified and directed. Note: Old cable may different size and length and credit will be given as actual obtained from site. |
| 7 | Supply and laying, connecting and testing in replacement XLPE underground cableinsulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 120 sqmm 3.5 corelaid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on walletc., complete all as specified and directed. Note: (i) Earth work,removing, returning filling and pipe will be measured and paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments, machinery or toolsif required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. |
| 8 | All as per Srl Item No 7.00 above but for 3.5 core 95 Sqmm,complete all as specified and directed. |
| 9 | All as per Srl Item No 7.00 above but for 3.5 core 70 Sqmm, complete all as specified and directed. |
| 10 | All as per Srl Item No 7.00 above but for 3.5 core 50 Sqmm, complete all as specified and directed. |
| 11 | All as per Srl Item No 7.00 above but for 3.5 core 35 Sqmm, complete all as specified and directed. |
| 12 | All as per Srl Item No 7.00 above but for 4 core 25 Sqmm, complete all as specified and directed. |
| 13 | All as per Srl Item No 7.00 above but for 2 core 10 Sqmm, complete all as specified and directed. |
| 14 | Supply, installation, testing and commissioning outdoor type cubical LT panelin replacement of size not less than 1.2 m x 1.2 m x 0.6 mwith outer shell made out of3.15 mm thick MS sheet and MS angle section 40 x 40 x 5mm on PCC 1:2:4 type B-2 platform 60cmabove the ground level and 45cm below the ground level, factory fabricated with front openable , lockable,having pad lock arrangement , louvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 micronsTPN aluminum bus bar 500 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:- |
| 15 | INCOMING:- |
| 16 | MCCB 4 pole 320A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 36KA (Main) |
| 17 | Indicator lamps RYB with control fuses- 01 set (set of three) |
| 18 | Digital Multifunction meter with V, A, F, PF, kW, kVA, Load hours, site selectable kWh/ kVAh Amps range (0-500) Amps & Voltage range (50-520) voltflush mounting type 4\"X4\" square dial with CT secondary site selectable 1A / 5A |
| 19 | OUTGOING:- |
| 20 | MCCB 4 pole 100A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 25KA- 05 Nos |
| 21 | Supply, installation, testing and commissioning outdoor type cubical LT panelin replacement of size not less than 1.2 m x 1.0 m x 0.6 mwith outer shell made out of3.15 mm thick MS sheet and MS angle section 50 x 50 x 5mm on PCC 1:2:4 type B-2 platform 60cmabove the ground level and 45cm below the ground level, factory fabricated with front openable , lockable,having pad lock arrangement , louvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 micronsTPN aluminum bus bar 500 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:- |
| 22 | INCOMING:- |
| 23 | MCCB 4 pole 320A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 36KA (main) |
| 24 | Indicator lamps RYB with control fuses- 01 set (set of three) |
| 25 | Digital Multifunction meter with V, A, F, PF, kW, kVA, Load hours, site selectable kWh/ kVAh Amps range (0-500) Amps & Voltage range (50-520) voltflush mounting type 4\"X4\" square dial with CT secondary site selectable 1A / 5A |
| 26 | OUTGOING:- |
| 27 | MCCB 4 pole 250A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 36KA-02 Nos |
| 28 | Supply, installation, testing and commissioning outdoor type cubical LT panelin replacement of size not less than 2.0 m x 1.2 m x 0.6 mwith outer shell made out of3.15 mm thick MS sheet and MS angle section 40 x 40 x 5mm on PCC 1:2:4 type B-2 platform 60cmabove the ground level and 45cm below the ground level, factory fabricated with front openable , lockable,having pad lock arrangement , louvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 micronsTPN aluminum bus bar 600 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:- |
| 29 | INCOMING:- |
| 30 | MCCB 4 pole 400A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 36KA (main) |
| 31 | Indicator lamps RYB with control fuses- 01 set (set of three) |
| 32 | Digital Multifunction meter with V, A, F, PF, kW, kVA, Load hours, site selectable kWh/ kVAh Amps range (0-500) Amps & Voltage range (50-520) voltflush mounting type 4\"X4\" square dial with CT secondary site selectable 1A / 5A |
| 33 | OUTGOING:- |
| 34 | MCCB FP 100A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 25KA- 06 Nos |
| 35 | Supply, installation, testing and commissioning outdoor type cubical LT panelin replacement of size not less than 1.2 m x 1.5 m x 0.6 mwith outer shell made out of3.15 mm thick MS sheet and MS angle section 40 x 40 x 5mm on PCC 1:2:4 type B-2 platform 60cmabove the ground level and 45cm below the ground level, factory fabricated with front openable , lockable,having pad lock arrangement , louvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 micronsTPN aluminum bus bar 600 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:- |
| 36 | INCOMING:- |
| 37 | MCCB 4 pole 400A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 36KA (main) |
| 38 | Indicator lamps RYB with control fuses- 01 set (set of three) |
| 39 | Digital Multifunction meter with V, A, F, PF, kW, kVA, Load hours, site selectable kWh/ kVAh Amps range (0-500) Amps & Voltage range (50-520) voltflush mounting type 4\"X4\" square dial with CT secondary site selectable 1A / 5A |
| 40 | OUTGOING:- |
| 41 | MCCB 4 pole 100A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 25KA- 03 Nos |
| 42 | MCCB 4 pole 63A, Adj Thermal & Magnetic release, 50 Hz, 415 Volts, 25KA -02 Nos |
| 43 | TPN 63A MCB B curve -02 Nos |
| 44 | DP 40A MCB B curve - 02 Nos |
| 45 | Supply, installation, commissioning in replacement of Busbar panel outdoor Step Type Design of size 1.0x1.0x.6m with DMC insulators locking arrangement MS sheet covering 3.15 mm thick pedestal mounted vermin and weatherproof including four legs of 60 cm long of angle iron 40x40x5mm, front openable door having canopy for protection all surfaces painted with powder coated painting, embedding and including 400 Amp rated aluminium bus bars 4 Nos duly drilled for making connection with nut bolts of suitable size with colour code tape complete with PCC 1:3:6type C1 using 20 mm graded aggregate forfoundation for legs and make good electrical connection complete all as specified and directed.Note: The rate are included with thimbles lugs, nut bolts, PCC foundation and aggregate. |
| 46 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, using galvanised iron strip 32×6mm with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 40 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point, including all earth work excavation, returning filling and disposal of surplus soil and testing on completion complete all as specified and directed. |
| 47 | All as per Srl item No. 19.00 but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, complete all as specified and directed. |
| 48 | S&F earth continuity conductor or main earthing lead of size 20x3mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. incl protection GI pipe light grade 25 mm bore, complete all as specified and directed. |
| 49 | S&F cable jointing kit for 1.1 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25-50 sqmm including necessary earth work, cutting of cable and jointing accessories & meggaring of cable complete all as specified and directed. |
| 50 | All as per Srl Item No 22.00 above but for cable of size 70 to 95 sq mm, complete all as specified and directed. |
| 51 | All as per Srl Item No 22.00 above but for cable of size 120-150 sqmm, complete all as specified and directed. |
| 52 | All as per Srl Item No 22.00 above but for cable of size 240 sq mm, complete all as specified and directed. |
| 53 | All as per Srl Item No 22.00 above but for cable of size 300sq mm, complete all as specified and directed. |
| 54 | S&F cable jointing kit for 1.1 KV grade cable for outdoor straight through , heat shrink type, joint complete with jointing material and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 sqmm including necessary earth work, cutting of cable and jointing accessories & meggaring of cable complete all as specified and directed. |
| 55 | All as per Srl Item No 27.00 above but for cable of size 35 sqmm, complete all as specified and directed. |
| 56 | All as per Srl Item No 27.00 but above for cable of size 50 sqmm., complete all as specified and directed. |
| 57 | All as per Srl Item No 27.00 above but for cable of size 70-95 sqmm,complete all as specified and directed. |
| 58 | All as per Srl Item No 27.00 above but for cable of size 120-150 sqmm, complete all as specified and directed. |
| 59 | All as per Srl Item No 27.00 above but for cable of size 240-300 sqmm, complete all as specified and directed. |
| 60 | S&F in replacement MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 36 KA including making connections with suitable size of aluminium lugs/ thimbles complete all as specified and directed. |
| 61 | All as per Srl Item No 33.00 above but of size 400A, complete all as specified and directed. |
| 62 | All as per Srl Item No 33.00 above but of size 250A, complete all as specified and directed. |
| 63 | All as per Srl Item No 33.00 above but of size 200A, complete all as specified and directed. |
| 64 | All as per Srl Item No 33.00 above but of size 160A, complete all as specified and directed. |
| 65 | All as per Srl Item No 33.00 above but of size 125A, complete all as specified and directed. |
| 66 | All as per Srl Item No 33.00 above but of size 100A, complete all as specified and directed. |
| 67 | All as per Srl Item No 33.00 above but of size 63A, 4 pole having 25 KA breaking capacity complete all as specified and directed. Note for Item No 33.00 to 40.00: If any MCCB burns or became UNSV during defect liability period, then it should be replaced by the contractor with the same make and of with same capacity. |
| 68 | S&F in replacement for VAF Digital Multifunction meter with accuracy class 0.5, CT secondary site selectable 1A / 5A flush mounting 96 x 96 mm with CT/PT site programmable having input voltage measurement range 50-520 VAC including makingsuitable size opening in existing panel complete all as specified and directed. |
| 69 | M&L for 75 mm thick, PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in path, paving etc finished even and smooth using extra cement complete all as specified and directed. |
| 70 | M&L for painting of panel board of (Area not more than 8 Sq mtr) inner & outer completewith two coat of synthetic enamel paint by spraying including filling cavaties with filler overa coat of primer after cleaning & sanding all dust/ rust including writing the Distribution/ Panel Numberand panel details, complete all as specified and directed.Note: The Quoted rates are inclusive of white wash to fountation of Panel Board/ Painting to Angle Frames. |
| 71 | Repair of LT panel of any type and anysize including replace of old unsv items such as busbar, insulaor, CT/PT coils, insulating sleaves, front and rear doors, door hinges, gland, lugs volt meter, ammeter, indicator, locking arrangement and internal copper wiring after cleaning of surface including removing rusted particles removing dust tightening nut, bolts welding complete all as specified and directedNote: (i)Cost of marking description on the front door as per direction of Engr-in-Charge is incl in quoted rate (ii)Cost of misc items like copper cable, lugs thimbles etc if required are included in quoted rates. (iii) Cost of welding works such ashinges, locking arrangement, door and angles are included in qouted rates. |
| 72 | M&L for fabrication of Aluminium busbar of size as per existing including, bending cold or hot in any size and shape all as directed and including RYB insulation mounted on epoxy cast/DMCinsulators complete all as specified and directed. |
| 73 | Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv forelectrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 5m x 1m, complete all as specified and directed. |
| 74 | S&F in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled red, with letters, figures and conventional skull and bones in signal white colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed. |
| 75 | S&F in replacement of on load change over switch with sheet steel Enclosure 415 V, 4 pole, 200 Amps capacity fixed on walls/MS frame/pole/LT panel for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches, complete all as specified and directed. |
| 76 | M&L for fixing of epoxy cast/ DMC as per existingfor 1100V grade insulators on the bus bars/panel complete all as specified and directed. |
| 77 | S&F in repair for GI pipe light grade of size 50mm dia laying in trenches/ under floor/on walls for protection of UG cables complete all as specified and directed. |
| 78 | S&F in repair for GI pipe light grade of size 80mm dia laying in trenches/ under floor/on walls for protection of UG cables complete all as specified and directed. |
| 79 | M&L for repair to road edges/ pothole by means of cold bituminous premixed dense concrete 30 mm consolidated thickness, using cold bitumen with 10-12 % binder content by weight of total mix spread manually rolled with minimum capacity 10 tonne and compacted to required camber and gradient by complete all as specified and directed. |
| 80 | M&L for Soling (or sub base) Spread thickness 100 mm with broken boulders or quarried stone, inter stices filled, surface formed and including rolled and consolidated to required gradient and camber, complete all as specified and directed. |
| 81 | M&L for 7.5cm thick (compacted thickness) WBM, with coarse aggregates of granite, trap or basalt ofgrading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread rolled and consolidated to gradient and camber required, complete all as specified and directed. |
| 82 | Taking out including excavation of defective LT Cable of size (25-120 Sqmm) & detecting fault, repair to joint including aluminium thimble, LT Joint,returning filling and relaying of cable in DWC pipe complete all as specified and directed. Note : LT Joint for 1.1 KV/ XLPE Cable will be measured and paid seperately in respective item. |
| 83 | M&L for replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour inclconnecting of the same in existing panel complete all as specified and directed. |
| 84 | M&L for spraying chemical Glyphosate 41 % (Round up) on area to remove unwanted vegitation/grass at various locations, complete all as specified and directed. |
| 85 | S&F anchor fastener 6mm/8mm of length 3\"\" for clamping of electrical items all as specified and directed. |
| 86 | Supply and installation of Retro Reflective Sign Boards for electrical installation of size 4 feet x 5 feet (print area) as per the following specifications:- (a) Post (pillar type) 55 mm dia 2 mm thickness SS 304 grade 9.5 feet long -02 Nos fittted with MS base plate 150 mm x 150 mm x 5 mm thickness at the bottom and 50 mm dia SS half balls on the top (b) Pipe for print area frame using 32 mm dia 1.2 mm thickness SS 304 Grade pipe and 05 Nos connecting pipes of 50 mm length.(c) SS rivetted strip 2 mm thickness and size 30 mm length & 25 mm width- 16 Nos.(d) 3 mm thick ACP sheet (aluminium composite sheet) of size 4 feet x 5 feet along with 1 mm thickness retro reflective material for approved colour and writing work in capital letters and numbers on both sides of ACP sheet.(e) PCC 1:2:4 type B-1 block of size 300x300x450mm - 02 Nos for grouting of sign board incl earth work. |