}

Tender For Supply Of Various Lab Equipments Items For Govt. Pg College Guna District Guna (M.P.), Guna-Madhya Pradesh

Department of Higher Education has published Tender For Supply Of Various Lab Equipments Items For Govt. Pg College Guna District Guna (M.P.). Submission Date for this Tender is 08-10-2025. Laboratory Equipment Tenders in Guna Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51253298
Tender For Supply Of Various Lab Equipments Items For Govt. Pg College Guna District Guna (M.P.)
Tender
Indian
Madhya Pradesh
Guna
08-10-2025

Tender Details

Supply Of Various Lab Equipments Items For Govt. Pg College Guna District Guna (M.P.) , Supply Of Various Lab Equipments Items For Govt. P G College Guna District Guna (M.P.) , Waterand Soil Testing Analysis Kit (Digital) : Range Ph 0 To 14.00 Resolution Ph 0.01 Accuracy Ph 0.01 ± 1 Digit Temp. Comp. 0 To 100 Deg. C. , Water Bath (06Holes) : 6 Hole8 Ltrs. , Waterbath(12Holes) :12 Hole 20 Ltrs. , Water Distillation Apparatus (Single Distillation Unit–2 Litre/Hour) : Single Distillation 5 Litres , Analytical Balance : Least Cosunt 0.0002G , Analytical Weight Box : 1-100G , Fractional Weight Box : 1-500Mg , Physical Balance : 250Gm Accuracy 0.1G , Digital Balance : Least Count 1Mg , Single Pandigital Balance : 0.1Mg 200G , Digital Photoelectric Colorimeter : 8 Filter,1 Ml , Digital Potentiometer : With Hot Plate And Electrodes , Digital Conductometer : With Cell 1Cc And 0.1Cc , D.O. Meter : Polarographic Do Range: Typically 0 To 90 Mg/L (Milligrams Per Liter) Or 0 To 600% Saturation.Rdo (Optical) Do Range: Usually 0 To 50 Mg/L Or 0 To 500% Saturation. , Digital Naphelo/Turbidity Meter : Digital Turbidity Cum Nephelometer Range:-, 200,1000 Ntu/Jtu Resolution:- 0.01 Ntu/Jtu Accuracy:- ± 3% Fs, ± 1Digit Display:- 3½ Digit 7-Segment Led Light Source:- Ir Led Detector:- Photodiode Sample System:- 60 X 25Mm Clear Glass Test Tubes Power:- 230 V ±10% Ac, 50 Hz Accessories:- Test Tube Set Of 2, Operation Manual, Dust Cover , Polarimeter Half Shade : The Specific Rotation (?) Is A Physical Property Defined As The Optical Rotation At A Path Length Of 1 Dm, A Concentration Of 10 G/L, A Temperature (Usually 20 °C), And A Light Wavelength (Usually Sodium D Line At 589.3 Nm) , Melting Point Apparatus :Melting-Point Measurement Range: Room Temperature - 400°C Setting Rate Of The “Starting Temp.”: 50°C~400°C =5 Min; 400°C~50°C =7 Min Minimum Digital Display: 0.1°C Size Of The Capillary: F1.4Mm (Outside Diameter) F1.0Mm (Inside Diameter), 90Mm Equipped With Color Camera And Color Monitor To Observe Melting Point With Ease Validation Program For Standard Samples 8 Operator Names Can Be Stored Graphic Lcd Display To Display All Test Parameters & Test Instructions , Digital Melting Point Apparatus :Melting Point Measurement Range : Ambient To 300 Deg C Starting Melting Point Temperature : Settable From 50 To 300 Deg C Heating Time : 3 Minutes (Up To 300Deg C) Cooling Time : 5 Minutes (From 300 Deg C) Accuracy : +/- 0.5 Deg Up To 200 +/- 0.8 Deg From 200 To 300 Temperature Display Resolution : 0.1 Deg C Rate Of Heating (Deg C Per Minute) , Abbe Refractometer : Safety Bs En 60950-1:11/2006 Emc En 55024 : 10/2003 En 55020 : 11/2005 , Tlc Kit : Outstanding Standardization And Quality Control Exceptional Adherence, Hardness And Surface Homogeneity. Analyzing Samples With High Matrix- Load Without Sample Preparation. Multiple Samples Analyzed In Parallel.Highly Cost-Efficient, Fast And Economical , Centrifuge : 6000Rpm , Corkboring Machine :Adjustable Guide That Permits Holes To Be Bored In Any Part Of A Stopper, The Knurled Chuck - 9/16 (14Mm) Shank Of The Eight, Plated-Steel Borers Included With The Unit. The Steel Borers Range From 3/16 To 5/8 (4.8Mm To 15.9Mm) In 1/16 (1.6Mm) Increments, , Distillation Apparatus : Single Distillation 5 Litres , Oven Hot Air : 14×14×14” , Voltage Stabilizer : 2Kv , Vertex Shaker : 6 Tube Capacity , Mixer Small : Moter Capacity 900 Watt , Water Bath(Cu) : 4” , Heating Mantle With Energy Regulator :500 W,2Litre , Single Crucible Heater : Helical Wire Coil Moldatherm® Insulation Platinel® Ii Thermocouple With 10Tm Compensated Lead Wire And Polarized Plug Ceramic Fiber Hearthplate Programmable Heat-Up To Setpoint Temperature Indicates Setpoint And Process Temperatures Temperature: 1200°C (2192°F) Maximumcrucible Sizes: 5” (Top Vestibule Id) X 8” (Heated Depth) , Water Bath Rectangularsingle Walled : 6 Hole 8 Ltrs. , Water Bath Rectangular :2 Hole , Kjeldahl Distillation Unit : Unit Of 3 Tests , Microwave Oven : 30 Ltr Convection Compatible , Soleextractionunit Apparatus: Unit Of 3 , Blower : 2 Kw Power , Water Analyser : Measures Parameters Like Organic Matter, Nitrate, Color, And Aromatic Hydrocarbons (Pah),Should Also Includes A Complementary Module For Measuring Po4, Cl2, No2, Fe, Al By Colorimetric Method, And Turbidity By Laser Diode. , F.E.T Charactrstics : Voltage-Controlled,High Input Impedancedevices Which Form An Integral Part Of Vast Variety Of Electronics Circuits , M.O.S.F.E.T Charactrstics :Triterminal, Unipolar, Voltage-Controlled ,High Input Impedance Devices Which Form An Integral Part Of Vast Variety Of Electronics Circuits , Thermistor Charactsics Apparatus : Instrument Comprise For Dc Regulated Power Supply 0-10 Vdc/150 Ma,Two Round Meter For Voltage And Current Measurement, One Thermistor Is Keptin Oven,Connectionof Suppliers, Meters , Photodiode Characterstics App: Wavelength Sensitivity (?P):940Nm.Open Circuit Voltage : 0.39V.Reverse Breakdown Voltage:32V.Reverse Light Current: 40?A.Reverse Dark Current:5Na.Risetime/Falltime:45/45Ns.Viewangle:80Deg. Package:5Mm , Solarcell Characterstics : Normal Operating Cell Temperature Open Circuit Voltage, Short Circuit Current Maximum Power Point Maximum Power Point Voltage, Maximum Power Point Current Nominal Voltage. , Photo Transisitor Characterstics App: Low-Cost Visible And Near-Ir Photodetection. Available With Gains From 100 To Over 1500.Moderately Fast Response Times. , Hartley And Colpitts Oscillators : Input:230Vac,+/-10%,50Hz,Singlephase. Tapped Auto Transformer Type Inductor , Transistorized Regulator Power Supply: Input:230Vac,+/-10%,50Hz, Singlephase. Output Voltage: 0 – 40 V Dc Continuously Variable Through Coarseand Fine: +/- 0.015 % Of Max Output Or Better Forb Variations Load Current , Series And Parallel Resonance Circuit: At Resonance The Parallel Circuit Produces The Same Equationas For The Series Resonance Circuit. Therefore, It Makes No Differenceif The Inductor Or Capacitor Are Connected In Parallelor Series , Battery Chrger 2 To 12Volt : 12V/2Amp Battery Charger Smps,Battery Voltage-12Hrs, Battery Cap.Upto14ah, Current2a , Callendor And Barne App To Det. The Value Of Mechanical Equivalent Of Heat: Callendar And Barne’S Apparatus Omegatype Cfb- 196.2. Constant Level Bath With Stand. 3. Battery Eliminator, 2-12V D.C. Insteps/Variable At 4Aicregulated And Short Circuit Protected Omega Type Be- 12/4 , Lee App To Det. The Hear Conductivity : For Determining The Relative Conductivity Of Thin Layers Of Materials Consist Of Cylindrical Brass Slab11.5Cm Dia And 12Mm Thick.On This Rests A 5 Cms Deep Hollow Cylinder Of The Same Dia With Inlet And Outlet Tubes. , Physical Balance: 1 To 10Kg, Wooden Double Door,1/5Mg , Screw Gauge : 0.22Mm, Brass Material, Range 0-25 , Stop Watch Digital :Timecap.23Hrs, Accuracy.3Sec/Day,Alarm-Yes , Ammeter D.C/A.C: Callendar And Barne’S Apparatus Omegatypecfb- 196.2.Constant Level Bath With Stand. 3. Battery Eliminator, 2-12V D.C. Insteps/Variable At4aic Regulated And Short Circuit Protected Omega Type Be-12/4 , Voltmeter D.C/A.C : Industrial Laboratory , Photo Conductivity Experiments : Industrial Laboratory , To Study The V-Icharactrsticsofthesolarcell : 115V,50/60Hz), Record The Characteristic Curve For A Photoresistor Photoconductivity , Ldr Charactrstics App :High Strength Superior Finish Lessmaintenance , Bending Of Beam : Power Supply 0-10Volt Dc, Voltmeter 0-10 Volt Dc, Ammeter 50Ma, 100W,50 Cm Wooden Plank , Measurement Of Low Resistance By Care Foster- : Precise Bridgearrangement, Galvanometer, Resistances And Dcpower Supply Are Provided On A Single Board, Dc Power Supply In Place Of Acellor Battery , Potentiometer : The Transducer Has Been Improved In Order To Guarantee Greater Reliability Under All Conditions , App To Study Response Curve For Lc Circuit: The Resonance Effect Of The Lc Circuithas Many Important Applications Insignal Processing And Communications Systems , Zener Diode As Voltage Regulator Power Supply Set :Package Contains: 1. Circuit Diagram (1Nos.) 2.Electronic Components.(Asper Component List) Without Battery 3.Description Of The Kit4. Components List , Spectrometer Prism : Equilateral Shape With Two Face Spolished, Inour Three Standard , Inertiatable :Backed By Profound Experience Of Our Experts, Weare An Unparalleled Name Engaged In Providing A High-Quality Assortment , Compound Pendulum: It Consists Of A Powdered Coated Steel Bar Of Dimensions 100×3.75×0.5Cm With A Number Of Equidistant Holes Drilled Along Its Length At Equal Intervals Of 5Cm , Cantilever To Determine Young Modulus :The Frames Are Fitted With Self Centering Chucks. An Accurately Graduated Micrometer Screw , Horizontal Torson App : Tearles Pattern For Investigating The Torsional Rigidity Of Rods Of Different Material And To Demonstrate That The Angle Of Twist Of A Given Rod Over A Fixed Length , App To Verify Newtons Law Of Cooling :Consists Of Two Copper Calorimeters 2X1Resting Inside At Rough Which Stands In An Outer Tank , Searle Apparatus To Determine The Coefficient Of Thermal : Backed By Profound Experience Of Our Experts,Weare An Unparalleled Name Engaged In Providing A High-Quality Assortment , Conductivity Transformer Sodium Vapour Lamp:5 And 35Watt, 420Volts, Single Phase,220 Input Volts , Mercury Lamp: 220-240Volt, 50Hz, Industrial , Transformer Of Mercury Lamp : 220-240Volt,50Hz,Industrial , Comp App To Determine Resolving Power Of Telescope: Optics Used In This Device Are Of Research Quality , Audio Frequency Generator: 1011Low Distortion Audio Generator That Is Used In Various High Scale Industries.It Is Strictly Tested , App For Measurement Of Capacitance And Inductance Us On Impedance At Different Frequency : Function Generator: Selected Wave With Following Specifications Frequency=1Khzamplitude:2V Duty Cycle = 50% , Study Of Lissajous Figure Trainer With Crod Tray: Standard Kit For Lissajous Figure With Cro, Frequency Calculation , Study Of Lissajous Figure Trainer With Cro: Standard Kit For Lissajous Figure With Cro, Frequency Calculation , Cro-Rectifier And Filter Characteristics Apparatus : Main Supply - 220-240Volt, Frequency - 50Hz, With Digital Storage Oscilloscope 100Mhz Bandwidth 2Ch Dual Channel , C.R.O. Single Trace100mhz : Digital Storage Oscilloscope Uoto 100Mhz Bandwidth , Dielectric Constant Apparatus: Mainly Used In Physics Labs 220V,50-60Hz, Single Phase, Analog Standard Kit , Half Wave And Full Wave Rectifier Kit : Standard Half Wave/Full Wave Rectifier With Cro To Trace The Wave Signal , Network Theorem Kit : 12-15V, 240Volt, Metal And Fiber,250Ma , Resonance Wave On Lcr : The Resonance Effect Of The Lc Circuit Has Many Important Applications In Signal Processing And Communications Systems. , Study Of Regulated Power Supply Using Transistor : Instrument Comprises Of Ac Power Supply, Three Meters To Assure Output Voltage, Output Current & Ac Ripples , Reading Telescope : Focusing Arrangement Is Given By Rack And Pinion. Complete On A Heavy Metallic Stand Having Pillar Of 18 Length Of 15Mm Diameter , Analog Multimeter : 50-60Hz,Analog Type, 220-250V,10A Current , Compound Microscope:Temp Ambient+10 C To 250C, Inner Chamber Stainless Steel, Exterior Powder Coated Gisheet, Fiber Glass Wool , Lead Accumulator: Battery Eliminator Need To Be Ideally Designed To Be Safe & Reliable Source Of Low Voltage D.C. , Battery Eliminator : 1000Ohms, Table Mounted , Dissecting Microscope : For Laboratory Usage , Resistance Box: Argonfilledtetrode,0-80V, Range 0.5-15V , Hybrid Solar And Wind Energy Trainer : 230 Av,27 Cms Dimensions*17Cms+- 15V Dc,2 Kgs Appx. , Distillation Apparatus Double Capacity 5 Litre: Instrument Comprises Of Ac Power Supply, Three Meters To Ensure Output Voltage, Output Current & Ac Ripples , Frank-Heartz Exp : Focusing Arrangement Is Given By Rack And Pinion. Complete On A Heavy Metallic Stand Having Pillar Of 18 Length Of 15Mm Diameter. , Ganong’S Potometer : 50-60Hz, Analog Type,220-250V,10A Current , Thermistor Characteristics App: Temp Ambient+10 C To 250C, Inner Chamber Stainless Steel, Exterior Powder Coated Gi Sheet, Fiber Glass Wool , Ganong’S : Quartz A Glass Tube, Which Is Bent Twice, And A Glass Cylinder Having A Wide Mouth , Slotted Weights/Hanger: Cylindrical Weights With A Radial Slot , Slide Cabinet With 12 Showcase : Slide Capacity: 4,500 Per Cabinet (54,000 Slides Total) Dimensions: 15.75 X 18.75 X 4.75 In. Color: Tan. Shop For Micro-Slide Cabinet Complete Unit With 12 Rows Of 6 Drawers With A Tan Base. , Quadrats : Area Of 0.25M , Rectangular/Circular/Irregular , Digital Thermometer : Upto 400Oc And 2 Decimal Fraction , Rheostate (Various Length) : 120 Watts To 2500 Watts In Single Tube. Higher Ratings With Multiple Tubes. Ohmic Value : 0.3O To 25K? Current Range : 0.3A To 40A , Binocular Dissecting Microscope: Upto 200X, Stereo Microscopes Offer A Zooming Range, Typically From 6.7X To 45X Or Higher, Dual Led Eluminator , Galvanometer: With 0.1 Fraction , Slide Box For 50 Slides : Lining: Cork, Lock Type: Thumb Latch Material: Abs Plastic Dimensions: 8.2 X 3.4 X 1.4 In , Miliammeter Milivolmeter/ Microammeter: With 0.1 Fraction (Range – 0 To 10 Ma, 0 To 10 Um And 0 To 10 Mv, 0 To 10 V) , Plug Key One Way/Two Way : 4Mm Terminal With 2 Removable Plug Includes Two Removable Plug With Plastic Guards , Slide Box For 50 Slides:Lock Type: Thumb Latch Material: Dimensions: 8.2 X 3.4 X 1.4 In , Reversing Key : A Plastic Bar With Two Terminals And Two Brushes Is Pivoted To Rotate Over Two Contact Strips , Four Way Key : 4 Mm Terminal With Removable Plug , Binocular Microscope: , Moarse Key : Brass Arm: 152 Mm X 12.7 Mm Square (6 X 0.5 Square) Main Bearing Block: 25.4 Mm Square (1 Square) , Slide Readar : High-Resolution Images With No Stitching Artifacts Or Patchwork Effects, Optimized Optical Beam Path, True Color Led For Brightfield Stains , Water And Soil Testing Analysis Kit :Ph, Conductivity, Tds, Do, Salinity, Mv & Temperature Measurements Highly Accurate & Stable User Friendly & Menu Driven Software 16 X 2 Line Alphanumeric Lcd With Backlit Printer Attachment Facility Storage For 999 Samples Mains Cum Battery Operated , Digital Multimeter : Accuracy: The Largest Allowable Error Under Specific Operating Conditions. Resolution: The Smallest Increment Of Change The Dmm Can Detect And Display. Range: Related To Resolution. Precision: Ability To Provide The Same Measurement Repeatedly Under The Same Conditions. Display Digits: The Number Of Digits Displayed. Display Counts: A Measure Of The Maximum Value The Dmm Can Display. , Ph Meter: Measurement Range For Ph: 0.0-14.00 Accuracy For Ph Measurement: ±0.01 Ph Resolution For Ph Measurement: 0.01 Ph , Soldering Iron: 200-500 0C , Travelling Microscope : Resolution: Typically In The Order Of 0.01 Mm, Travel Range: Horizontally: Up To 22 Cm. Vertically: Up To 15 Cm. Slow Motion Knobs: Provided For Accurate Readings. Microscope Tube: Eyepiece: 10X Magnification. Objectives: Available In 15 Mm, 50 Mm, Or 75 Mm. , Digital Balance: ? 0.001Mg , Bar Pendulumb : Standard Configuration , Sodium Vapor Lamp : 55 W , Use Of Vibration Magnetometer To Study A Field: Standard Configuration , Apparatus To Determine The Value Of Plank’S Constant Complete With Photocell, Light Source, Set Of Filter And Power Supply : Halogen Lamp, Digital Voltmeter And Ammeter, Vacuum Photo Tube, Filters Of Different Colors. , Analytical Balance: Capacity 62G To 320G And A Minimum Readability From 0.01Mg , Autoclave Portable : 29 Liters , Automatic Burette: 1 Ltr And 500 Ltr , Blood Cell Calculator : 35000 To 100,000 Results Including Histograms And Scatter Diagrams Etc. , Chart & Cds Related To Syllabus: Based On Nep Syllabus For Geography , Digital Haemoglobinometer: Self-Calibration Sensors That Takes <60 S For Each Hemoglobin Estimation , Digital Ph Meter : Ph Range:=2.000 To =14.000 , Digital Single Pan Balance: Capacity: 200G , Digital Spectrophotometer: Single Beam , Digital Thermometer: Accuracy : ±1°C In The Range Of -30°C ~ 150°C , D:Igital Turbidity Meter : Detector: Photodiode, Light Source: Ir Led Display: 3½ Digit 7-Segment Led Sample System: 60 X 25Mm Clear Glass , Dissecting Microscope: Monocular 90° , Dissecting Tray: Rectangular With Flanged Edge , Electronic Digital Balance (0.01 Mg) : Least Count:0.01 Mg , Electronic Digital Balance (0.1 Mg) : Least Count: 0.1 Mg , Electrophoresis With Power Supply: 7X10cm Gel Tray Uv Transparent , Glucometer : Measuring Range: 30 To 600 Mg/Dl Blood Sample Size: Typically Around 0.6 ?L Test Time: Usually 5 Seconds , Haemocytometer (Complete Box):Grid Size: 3 X 3 Mm Total Area: 9 Mm² Depth Of Chamber: 0.1 Mm Volume Of Each Small Square: 0.0001 Mm³ (0.1 Nl) Number Of Squares On The Grid: 80 Area Of Each Small Square: 1/80 Mm² (0.0125 Mm²) , Heating Mantle With Regulator Cap1litre : Material-Glass Yarn, Controller-Energy Regulator Compatible, Power-300 W, Voltage -220 V, Capacity1 Litre, Temperature 300 Degree C , High Speed Centrifugea : 10000 Rpm With 6 Voyl , Homogenizer : Quick Connect Rotor Stator Generators, Ranging From 5 To 20 Mm (0.20 To 0.79) In Diameter, Samples As Small As 0.03 Ml Or As Large As 1 L , Laboratory Hot Air Oven : Upto 250Oc With Micro Controller , Magnetic Stirrer With Hot Plate : Speed Range:3000Rpm, Temp-Upto 500Oc , Medico Centrifuge Machine : Upto 8000 Rpm , Micropipette : 0.5-1 Ml , Microtome(Rotary) : Specimen Object Feed Of 25 Mm And Vertical Stroke Length Of 55- 60 Mm, And Blade Holder Setting Angle Up To 10° With Marking Of 0, 5 And 10° In The Blade Holder. , Monocular Microscope:Aplantic 10Xandacromatic 20X , Oven(125Litres) :Upto 500Oc , Pcrthermal Cycler ; 100–150 Vac, 50–60 Hz; 220–240 Vac, 50–60 Hz; 700 W Maximum Display 5.7 In. , Permanent Slides: Standard Specifications , Refrigerator–310 Litres : Capacity 310 Litre , Slide Cabinet With 12 Showcase : Size 480 Mm X 480Mm X 140Mm , Slide Cabinet With 6 Showcases: Size 30Mm X 460Mm X 120Mm , Slide Warming Table :Stainless Steel With Evenly Distributed Heating Elements, Pt 100 Sensor , Sphygmomanometer :Splash-Resistant Housing, Manual Inflation And Deflation, Two Aaa Batteries Included, 1500-3000 Readings Depending On Back-Light Use, Auto-Off Function. , Staining Racks :Wooden, Dimensions: 42.5 X 10.2 X 3.8 Cm , Syringe Needle Destroyer : Destroy Syringes From 18 Gauge To 28 Gauge On/Off Switch With A Pilot Lamp , Thin Layer Chromatography Apparatus: Minimum Div. 0.25Mm , Uv Trans-Illuminator: Wavelengths: Available In 302 Nm, Intensity: High, Medium, And Low Settings. Tube Type: Equipped With 25-Watt Uv Tubes. , Voltage Stabilizer :Range 100-300 Volt , Hot Plate : Speed Range:3000Rpm, Temp-Upto 400Oc, , Water Analyzer : Measurement Of Po4, Cl2, No2, Fe, Al By Colorimetric Method And Turbidity By Laser Diode, Range - 0-600 Abs/M, Typical Repeatability For Low Values (<10% Fs), , Vortex Shaker: Speed Range:5000Rpm

Key Value

Document Fees
INR 5000 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail