| 1 | A. 132KV TRANSMISSION LINE |
| 2 | Towers |
| 3 | i) A-TypeTower (0 to 2 Degree) (3.3045 MT) |
| 4 | ii) C-TypeTower ( 15 to 30 Degree) (4.8792 MT) |
| 5 | iii) 3M extension for C-Type Tower (0.9066 MT) |
| 6 | iv)6M extension for C-Type Tower (1.8561 MT) |
| 7 | v)9M extension for C-Type Tower (3.0376 MT) |
| 8 | vi) D-TypeTower (30 to 60 Degree) (6.3384 MT) |
| 9 | vii) 3M extension for D-Type Tower (1.2961 MT) |
| 10 | viii) 6M extension for D-Type Tower (2.4506 MT) |
| 11 | ix) 9M extension for D-Type Tower (4.0124 MT) |
| 12 | x) 18M extension for D-Type Tower (8.2275 MT) |
| 13 | Templates adjustable for |
| 14 | i) A-Type Tower (0to 2 Degree) (0.7149 MT) |
| 15 | ii) C-Type Towers( 2to 30 Degree) (1.2197 MT) |
| 16 | iii) D-Type Towers( 30to 60 Degree) (1.4792 MT) |
| 17 | Galvanized Bolts & Nuts ( with spring washers) |
| 18 | Tower accessories |
| 19 | i) Pipe Earthing |
| 20 | ii) counterpoise earthing |
| 21 | iii) Danger Plate |
| 22 | iv) Number Plate |
| 23 | v) Phase Plate (Set of Three) |
| 24 | vi) Bird Guard (Set of Three) |
| 25 | vii) Anti climbing device(with Barbed wire) |
| 26 | Conductor ACSR \"Panther\" |
| 27 | Conductor accessories |
| 28 | i) Mid span Compression Joint |
| 29 | ii) Repair Sleeve |
| 30 | iii) Vibration Damper |
| 31 | iv) Armour rod |
| 32 | v) P.G Clamp |
| 33 | OPGW Equipment |
| 34 | i) 24 Fibre (DWSM) OPGW Fibre Optic Cable (with central fibre optic unit of steel tube design) |
| 35 | ii) Suspension Clamp Assembly for 24 Fibre OPGW Clamp |
| 36 | iii) Dead End tension clamp for 24 fibre OPGW |
| 37 | iv) Tension Fitting Assembly for 24F OPGW including all accessories for Joint Box (Splicing) |
| 38 | v) Passing tension clamp for 24 fibre |
| 39 | vi) Tension Fitting Assembly on Suspension Tower for 24F OPGW including accessories at Joint Box (Splicing) Location |
| 40 | vii) Vibration Damper for 24 fibre OPGW |
| 41 | viii) Down Lead clamp Assembly for 24 fibre OPGW |
| 42 | ix) Joint Box for 24 fibre OPGW |
| 43 | FODP |
| 44 | i) OPGW Fibre Optic Distribution Panel (FODP); Indoor |
| 45 | Fibre optic approach cable and accessories |
| 46 | i) 24F (DWSM)Approach Fibre Optic Cable |
| 47 | Disc Insulator (Anti Fog) |
| 48 | i) 70KN |
| 49 | ii) 120KN |
| 50 | Hardware for Insulator Strings |
| 51 | i) Single Tension fittings |
| 52 | ii) Double Tension fittings |
| 53 | iii) Single Suspension with Hanger |
| 54 | Tool & Plants |
| 55 | i) Hydraulic Compressor |
| 56 | ii) Hand Winch with 150m Rope 12 |
| 57 | iii) Come along clamp for conductor |
| 58 | iv) Regulation bridge |
| 59 | v) Pulley/Roller Heavy duty for conductor |
| 60 | vi) Die set for panther |
| 61 | vii) Die set for earthwire |
| 62 | B. 132/33KV SUB STATION |
| 63 | 12.5 MVA, 132/33 KV,Power Transformer (ONAN). |
| 64 | 10MVA, 33/11KV, Power Transformer (ONAN) |
| 65 | 145 KV, 12.5KA,800ASF6 Gas Circuit Breakers3Phase Auto reclosing |
| 66 | i) 3 phase Auto reclosing |
| 67 | ii) Single phase Auto reclosing (set of 3) |
| 68 | iii) 36 KV, 630A,10KASF6 Gas Circuit Breakers |
| 69 | Motor Operated Isolators |
| 70 | (a) 145 KV, 800A, 12.5KA Out Door Isolators |
| 71 | i)with E/Blade |
| 72 | ii)without E/Blade |
| 73 | (b) 36KV, 630A,10KA Isolators |
| 74 | i)with E/Blade |
| 75 | ii)without E/Blade |
| 76 | Lightning Arrestor |
| 77 | (a) 120 KV, 10KAwith Insulating Base & Surge Counters |
| 78 | (b) 30 KV, 10KAwith Insulating Base & Surge Counters |
| 79 | Current Transformer |
| 80 | (a) 132 KV Line CT |
| 81 | (b) 132KV Transformer CT with Different Ratios with PS |
| 82 | (c)33 KV with Different Ratios with PS |
| 83 | (d) 33KV Line CT |
| 84 | (e) 17.5KV, Class –I Core NEUTRAL CT(300/150/1A) |
| 85 | 132KV Potential transformers/CVT |
| 86 | (a) 132 KV Line CVT |
| 87 | (b)132KV Bus PT |
| 88 | 33KV Potential transformers |
| 89 | (a) 33 KV |
| 90 | 132KV Control & Relay Panels (Duplex/Simplex) |
| 91 | i) Line feeder & ControlRelay Panel |
| 92 | ii) Transformer Control & Relay Panel |
| 93 | iii) Transfer Bay Control & Relay Panel |
| 94 | 33KV C&R Panels |
| 95 | i) Transformer Control & Rely Panel |
| 96 | ii) Feeder Control & Relay Panel |
| 97 | 11kV Control & Relay Panel (with 2-incomming& 5 -outgoing) |
| 98 | Supply of Power Cables |
| 99 | i) 3C X 400 Sq.mm XLPE 11KV Power cable |
| 100 | ii) 3C X 185 Sq.mm XLPE 11KV Power cable |
| 101 | iii) 3 1/2C X 70 Sq.mm XLPE 1.1KV Power cable |
| 102 | iv) 4C X 16 Sq.mm XLPE 1.1KV Power cable |
| 103 | v) 4C X 6 Sq.mm XLPE 1.1KV Power cable |
| 104 | Supply of Control Cables |
| 105 | i) 2C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 106 | ii) 5C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 107 | iii) 7C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 108 | iv) 10C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 109 | v) 12C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 110 | vi) 14C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 111 | vii) 19C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 112 | viii) 24C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 113 | SWITCHYARD & COMPOUND LIGHTING |
| 114 | i) 200W LED with Fittings on Poles |
| 115 | ii) 200W LED on Switchyard Structures |
| 116 | iii) Bay Marshalling Box |
| 117 | iv) Lighting Distribution Box |
| 118 | v) Lightening Mast Tower (GI Structure) |
| 119 | FIRE-FIGHTING EQUIPMENT |
| 120 | i) 50Lb, Dry Powder Type for switchyard |
| 121 | ii) Foam Type, 1 gallonwall mounted for battery room |
| 122 | iii) Wall mounted CO2, 10Lb Capacity for control room |
| 123 | iv) CO2, 50Lb Capacity on trolleys for transformers. |
| 124 | v) Sand Bucket (4Ltr) Stand with 6 Buckets per Stands for switchyard and Control Room. |
| 125 | RTU |
| 126 | Bus Bar i/c Insulator Strings, Connectors, Shielding Wires, Conductors, Post Insulators(132KV & 33KV)etc |
| 127 | D.C Equipments:- |
| 128 | (i) 110V, 250AH Battery with Accessories(Maint. free) |
| 129 | (ii) 110V Battery Charger Float Cum Boost. |
| 130 | (iii) 110V, DC Distribution Board |
| 131 | (iv) 48V, 250AH Battery with Accessories(Maint. free) |
| 132 | (v) 48V Battery Charger Float Cum Boost. |
| 133 | (vi) 48V, DC Distribution Board |
| 134 | L.T A.C PANEL (6 Feeder) |
| 135 | Earthing (Grid) System with GI Flats of 50 x 6mm, 75 x 8mm andEarth Electrode (40mm diameter GI Pipe & 32mm dia Solid rod) |
| 136 | GI Switchyard & Equipment Structures with GI Bolts & Nuts, L.M.tower (4MT) (87 +4 = 91MT) |
| 137 | Rail Tracks |
| 138 | Station Transformer 11/0.4KV, 250KVA with reqd. materials |
| 139 | C. 132KV LINE BAY AT HUNDUNG |
| 140 | 145 KV, 12.5KA, 800ASF6 Gas Circuit Breakers, SinglePhase Auto reclosing |
| 141 | Motor Operated 145 KV, 800A, 12.5KA Out Door Isolators |
| 142 | i)with E/Blade |
| 143 | ii)without E/Blade |
| 144 | 120 KV, 10KALA with Insulating Base & Surge Counters |
| 145 | 132 KV Line CT |
| 146 | 132 KV Line CVT |
| 147 | 132KV ControlRelay Panel (Feeder/Control Panel) |
| 148 | Supply of Power Cables |
| 149 | i) 4C X 16 Sq.mm PVC 1.1KV Power cable |
| 150 | ii) 4C X 6 Sq.mm PVC 1.1KV Power cable |
| 151 | Supply of Control Cables |
| 152 | i) 2C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 153 | ii) 5C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 154 | iii) 7C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 155 | iv) 10C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 156 | v) 12C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 157 | vi) 14C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 158 | vii) 19C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 159 | viii) 24C X 2.5 Sq.mm PVC 1.1KV Power cable |
| 160 | Bus Bar materialsi.e ACSR conductor, insulator strings etc. |
| 161 | Galvanisedsteel structure |