}

Tender For . See Chapter 4 And 6 For Detailed Specification And Eligibility Criteria. , Supply, Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling/, karaikudi-Tamil Nadu

Council Of Scientific And Industrial Research has published Tender For . See Chapter 4 And 6 For Detailed Specification And Eligibility Criteria. , Supply, Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling/. Submission Date for this Tender is 08-10-2025. Cutting Crimping and Punching Tools Tenders in karaikudi Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

51250464
Tender For . See Chapter 4 And 6 For Detailed Specification And Eligibility Criteria. , Supply, Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling/
Tender
Indian
Tamil Nadu
Karaikudi
08-10-2025

Tender Details

. See Chapter 4 And 6 For Detailed Specification And Eligibility Criteria. , Supply, Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling/Heating Having 100% Hermetically Sealed Inverter Type Twin Rotary/Scroll Compressor(S),Minimum Two Compressors (With Individual Separate Pcb) For Above 14Hp Modules, Microprocessor Based Controller, Top Discharge Type Condensing Unit(S), With R-410-A Refrigerant Or Equivalent, Vibration Isolators With Suitable Foundation Etc. Complete As Required. To Have Better Efficiency Condenser Fan Shall Be Capable To Operate At Different Speed With Respect To Load. The Unit Shall Deliver The Rated Capacity And In Confirmation As Per Is 18728:2024 And Cpwd Specifications And Work Even At 50°C Ambient Temperature Without Tripping. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 39 Degree Celcius.The Unit Shall Be Suitable To Work On 400V +/- 10%, 3 Phase, 50Hz Ac Power Supply And Bms Compatible. The Unit Shall Be Filled With First Charge Of The Refrigerant And Ready For Use As Required. The Condenser Should Be Coated With A Hydrophilic Film To Prevent Water Accumulation On The Surface Of The Heat Exchanger, Enhance Water Dispersion, And Reduce The Risk Of Degradation, Thereby Improving Overall Performance And Durability. The Indian Seasonal Energy Efficiency Ratio (Iseer) Of The Unit Shall Be As Per Energy Conservation And Sustainable Building Code (Ecsbc) 2024 As Below And Complete As Per Cpwd Specification, Connections, Inter Connections Etc. As Required. (For Capacity <40 Kwr Iseer 7.4, Capacity > 40 And <70 Iseer 7.5, Capacity > 70 Iseer 7.6 For Super Ecsbc Building)- For Cooling Only , The Vrv/Vrf Unit Should Be An Higher Energy-Efficient Model Compliant With Bee Regulations. The Unit Should Have Free Phase Technology / Phase Loss / Missing Phase So That Unit Can Work In Case Of Phase Reversal And Pcb Protection Low And High Voltage Support. Compressor Operate Together As One Logical Unit, Sharing Refrigerant Load, Control Signals, Allows Continued Operation (If One Compressor Fails Continuosly Running Remaining Compressor, Like As Master And Slave Configuration). Including All The Dip Switches And/Or Control Wiring As Per Oem Recommendation , 18 Hp - Vrv/Vrf Odu Unit , Indoor Unit – Four Way Cassette Ac , Supply, Installation, Testing And Commissioning Of Following Minimum Capacity 4 Way Cassette Type Indoor Ceiling Mounted Unit Equipped With Synthetic Washable Media Pre-Filter, Fan Section With Low Noise Fan / Coil, Electronic Expansion Valve, Outer Cabinet, Drain Pump, Grill, Necessary Supports, Vibration Isolation, Decorative Panels, Occupancy Sensors, Cordless Remote Control Etc., Suitable For Operation On Single Phase 230 V ± 10%, 50Hz Ac Supply, Complete, As Required. The Indoor Units Must Shut Down Upon Receiving A Singal From The Bms System/Fire Signals. The System Shall Be Capable To Adjust Air Flow As Per Room Requirement In Auto Mode. The Cooling Capacity Of Indoor Unit Will Be At Air Inlet Conditions Of 27 Degree C Db And 19 Degree C Wb Temperature. (Make Will Be Same As Of Outdoor) , The 4 Way Cassette Cassette-Type Air Conditioning Indoor Unit Shall Be Supplied With An Integrated Sensor System, Including Motion/Occupancy/Floor Sensors, All Factory-Mounted Within The Indoor Unit And Fully Compatible With The Controller. These Sensors Shall Be Capable Of Detecting The Presence, Absence, And Activity Level Of Occupants In The Room, Thereby Enabling Intelligent Control Of The System For Enhanced Comfort And Energy-Saving Performance. The Unit Shall Also Have A Factory-Provided Provision For Fresh Air Intake, Such As A Dedicated Knock-Out Port Or Inbuilt Hole, Suitable For Direct Connection Of A Fresh Air Intake Duct Box In Future. , 1.6 Tr - Four Way Cassette Type Indoor Ceiling Mounted Unit (Round Flow) , 2.0 Tr - Four Way Cassette Type Indoor Ceiling Mounted Unit (Round Flow) , Copper Refrigerant Piping , Supply, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Vrv/Vrf System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastomeric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessories As Per Specifications Etc. As Required , Copper Pipe Laying Each Indoor Unit To Outdoor Unit Should Be Properly Supported With Perforated Gi Cable Trays With Closing Cover And Covered Arrangements From Outdoor To Indoor As Required At Site. Additionally, The Copper Pipes Must Be Wrapped With Fiberglass Insulation Tape And Coated With Uv-Resistant Paint. , The Size Of Refrigerant Pipes Shown Below Are Tentative. The Required Size Of Pipe Shall Be Designed By The Vendor As Per The Manufacturers Recommendations. , 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , 9.5 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , 15.86 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , 19 Mm Dia (Od) (Hard Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , 22.2 Mm Dia (Od) (Hard Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , 25.4 Mm Dia (Od) (Hard Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , 28.58 Mm Dia (Od) (Hard Drawn) With Tube Thickness 1.2 Mm With 19 Mm Thick Insulation , Refnuts / Y Joints / Separation Tubes , Supply, Installation, Testing And Commissioning Of Y/T/Multi Joints. Joints Shall Be Of Same Original Equipment Manufacturer (Oem) Make As Of Odus And Idus , Indoor Units , Electrical Power Cable / Communication Cable / Accessories , Supply, Laying, Dressing And Testing Of The Following Sizes Of Frls Heavy Duty Pvc Insulated Round Sheathed Flexible Copper Conductor Cable (I.S.I) Of The Following Sizes For Power Connection From Plug Socket/Mcb Board To Each Indoor & Control Cum Communication Transmission Screened Shielded Wiring From Outdoor To Indoor Unit And Wired Remote Controllers Covered With Pvc Conduit / Perforated Cable Tray / Mini Trunking Pipe To Be Laid On Wall / Rcc Ceiling / Cross Beams Including Cutting, Drilling The Wall Where Ever Required And Making Good The Same, Supporting, Andclamping Etc. Duly Industrial Cable For Voltage Grade Upto: 11Kv As Per 694:2010 As Required. (The Size Of The Cable Will Be As Per The Oems Recommendation) , 3 Core X 2.5 Sqmm Isi Market Frls Pvc Insulated Copper Conductor Cable With Pvc Conduit And Accessories , 2 Core/3 Core X 1.5 Sqmm Isi Market Frls Pvc Insulated Screened Shielded Communication Cable With Pvc Conduit And Accessories , 16 A - 3 Pin Plugtop With Indicator (Heavy Duty) , Supply And Laying4 Core X 10 Sqmm Frls Heavy Duty Xlpe Insulated Armoured Copper Conductor Industrial Power Cable(I.S.I) From Main Mcb To Vrf Outdoor Unit Covered With Pvc Conduit / Perforated Cable Tray / Mini Trunking Pipe To Be Laid On Wall / Rcc Ceiling / Cross Beams Including Cutting,Drilling The Wall Wherever Required And Making Good The Same,Includingsupporting, Andclamping Etc As Required At Site. Duly Industrial Cable For Voltage Grade Upto: 11Kv As Per 7098-1 :1998 As Required. , Providing And Fixing 4.00 Mm Dia(8 Swg)Copper Wire On Surface Or In Recess For Loop Earthing On Existing Surface/Cable Tray From Main Power Panel To Outdoor Units As Required , Other Miscellaneous Work , Supplying, And Laying Of Following Dia Rigid Heavy Duty Upvc Drain Water Pipingcomplete With Accessories (Elbows, Tees, Reducers, Sockets, U-Trap Etc.) Supports, Insulated With Xple Class - O Tubular Insulation/With Class-O Closed Cell Elastomeric Nitrile Rubber Tubular Sleeves Sections Of Specified Thickness Etc. Complete As Required. (The Size Of The Condensate Drain Water Pipe Will Be As Per The Oems Recommendation) , 32 Mm Dia Rigid Upvc Pipe With 13 Mm Thick Insulation And Accessories , 40 Mm Dia Rigid Upvc Pipe With 13 Mm Thick Insulation And Accessories , Supply And Charging Of Additional Refrigerant Gas R410a Complete As Required , Supplying And Installing Following Size Of Perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Closing Covers, Bend, Reducers,Tee Joints, Placing On Terrace/Side Wall Suspended From The Ceiling With Or Supported From Floor/Wall G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. , 300 Mm Width X 75 Mm Depth X 2.0 Mm Thickness - Cable Tray With Closing Cover , 300 Mm Width X 75 Mm Depth X 2.0 Mm Thickness - Cable Tray Bend With Closing Cover , 300 Mm Width X 75 Mm Depth X 2.0 Mm Thickness - Cable Tray Tee With Closing Cover , Lifting, Shifting, Positioning Of Vrf Outdoor/Indoor Unitsincluding Handling Using Crane/Manpower, Placementover The Anti Vibration Mounting Pads Fixed On Ms Rails Or Pedestal, Anchoring With Bolts & Nuts, Leveling, Necessary Scaffolding Arrangements, And All Safety Measures As Required At Site. , Lifting, Shifting, Positioning Of Vrv/Vrf Outdoor Unit - 18 Hp Odu Unit , Lifting, Shifting, Positioning Of Vrv/Vrf Based 1.6 Tr/2.0 Tr Cassette Type Idu Unit , Supply, Installation, Testing, And Commissioning Of Touch-Type Wired Remote Controller Suitable For Vrv/Vrf-Based Four Way Cassette Indoor Units. The Controller Shall Be Sleek And User-Friendly With An Aesthetic Front Panel, Having A Clear Touch Interface For Intuitive Operation. It Shall Support Group Control Of Multiple Indoor Units, Timer-Based Scheduling, Mode Setting, And Temperature Control. Complete With All Wiring, Accessories, Connectors, And As Required For Proper Functioning. , Minor Civil Works Such As Making Holes/Cuttings In Walls, Slabs, Or Partitions For Laying Copper Piping, Electrical Cables, And Drain Piping, Etc., Including Plastering, Finishing, And Painting To Match The Original Surface. All Labour, Materials, Tools, Scaffolding, And Disposal Of Debris Included. The Works Shall Be Executed In A Neat Workmanlike Manner As Required. , Comprehensive Annual Maintenance Contract (Camc) Charges Per Year For Vrv / Vrf Ac System (Inverter Model), Covering Complete System Including Indoor Units (Four-Way Cassette Type), Labour, Preventive Maintenance, Breakdown Service, Necessary Spares, Consumables, Idu & Odu Pcbs, And Refrigerant Gas Refilling, Etc. As Required. , Camc For 1St Year , Camc For 2Nd Year , Camc For 3Rd Year , Camc For 4Th Year , Camc For 5Th Year

Key Value

Document Fees
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail