| 1 | Cleaning the storm water drain with various sizes including collection of all unwanted leaves, precast slab removal & replacement , silt and other unwanted debris materials, removal and disposal of the same with a lead of 200 metres etc complete and as directed by the Engineer in charge |
| 2 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm all complete and as directed by the Engineer in charge. |
| 3 | Removing Sewage water with sludge from Septic tank / Champers/ Pipe lines by using mechanical equipments to remove the effluent and conveying the sludge\"s by tanker lorry (minimum capacity 9000 litrs) and disposal at out side of campus as a approved area by a corporation including loading and unloading, removal and replacing the cover slabs, cleaning in and around the area of septic tank / champers / Gully area complete and as directed by the Engineer in charge. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(a) All kinds of soil. |
| 5 | Supplying and filling in plinth with M.sand under floors, including watering, ramming, consolidating and dressing all complete as per specification and as directed by the Engineer in charge. |
| 6 | Providing and laying plain cement concrete 1:4:8 using 25mm maximum size graded aggregates including mechanical mixing, transporting and placing in required position, ramming, compaction, levelling, curing, shuttering, dewatering if any, complete all as per specification for levelling courses in foundation for walls, footings, floor drains etc., encasing pipes and other required works complete all as per specifications and as directed by Engineer-in-Charge |
| 7 | Providing and placing in position factory made machine batched & machine mixed Precast RCC perforated drain covers, manhole chamber cover and of various sizes, ofM-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges, providing 2 Nos. 12 mm dia bar for hooks etc including cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. |
| 8 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 200 metres lead as per direction of Engineer - in – Charge. |
| 9 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 200 metres lead as per direction of Engineer-in-charge.(a) In cement mortar |
| 10 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 11 | Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 12 | Providing plastering to the internal surfaces of brickwork/concrete at all elevations in cement mortar 1:4, 12mm thick finished with a floating coat of neat cement including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications and as directed by the Engineer – in – charge. |
| 13 | Providing plastering to the external surfaces of brickwork/concrete at all elevations in cement mortar 1:4, 20mm thick finished with including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications and as directed by the Engineer-in-charge. |
| 14 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area sq. meters and under, including cutting the patch in proper shape, raking out joints, and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer- In-Charge. |
| 15 | (a) above 1.00 to 2.00 Sqm Area |
| 16 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead |
| 17 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC or brick work including scafflodingas per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 18 | Providing, mixing and applying damp proof coat on internl dampness of RCC or brick work plasteringin internal walls and ceilingsurface with Mixing ratio, By weigh of 1:1:1 (1 part of Base : 1 part of Hardener: 1 part of : Water) and as per specifications and direction of Engineer-In-charge |
| 19 | Cleaningsunshades, roof building terrace gutters at all levels of various building, removing the vegetation growth, cleaning the drain pipes, spouts, removal of waste material if any periodically as and when required including necessary ladders and scaffolding arrangement, conveying the removed unwanted materials to the bins as directed with lead above 200 meters, complete all as directed by the Engineer-in-charge. |
| 20 | Removal of unwanted plants with main route at all levels, from wall / floors sunshade, gutters including floor& wall chipping and packing by concrete & , plastering etc as per site requirements including material , labour, scaffolding etc as per specification at all lifts and all as directed by the Engineer. |
| 21 | Providing and applying Painting wooden doors, MS grills with One or more Coats of synthetic enamel paint( Asian or approved brand colour and manufacturer) at all lifts over a old surface including cost of all materials, labour, preparing the surfaces, Removing the paint by scraping, rubbing applying primer and wood filler wherever required . All as per specification and as directed by the Engineer- in- charge. |
| 22 | Providing and applying Painting wooden doors, MS grills with two or more Coats of synthetic enamel paint( Asian or approved brand colour and manufacturer) at all lifts over a old surface including cost of all materials, labour, preparing the surfaces, Removing the paint by scraping, rubbing applying primer and wood filler wherever required . All as per specification and as directed by the Engineer- in- charge. |
| 23 | Labour engagement for unmeasurable items of works such as masonry touch up works, cleaning works, furniture and materials shifting to enable taking up the maintenancewoks as per the direction of Engineer in charge. |
| 24 | Helper |
| 25 | Mason |
| 26 | Painter |
| 27 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc, complete |
| 28 | Prepare surface and re - polishing the old wooden surface using approved quality & make French polish /varnish including bees waxing wood filler etc., and such other required materials, one or more coat to give an even shade. |
| 29 | Repair of cracked portion in the existing walls and making V groove, packing the cracks with necessary approved filler materials, curing, scaffolding at all levelsand cleaning the area complete anddirected by the Engineer-in-charge. |
| 30 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface : Water thinnable cement primer |
| 32 | Providing and applying wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (a) Two coats |
| 33 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (a) One coat |
| 34 | PU INJECTION GROUTING1. Holes of 10mm dia shall be drilled on the leakage/damp spot in the Ceiling of the R.C slab using a portable Electric drill and a non-return ball valve packer shall be fixedin the holes.2. Supplying and injecting PU based foam injection grout MEYCO MP355 1K or approved equivalent brand– through the above fixed packers using a High-pressure one component Resin Injection pump until point of refusal. In case dripping of resin is observed through the packer hole, then the same shall be temporarily plugged with Masterseal 505 – Instant plugging compound. Note: Whilst we recommend the simultaneous injection of Acrylate Resin Masterflex 810 to stabilize the leak zone, this additional process would involve the fixing of an additional packer alongside the one fixed as in (1) above and the Acrylate resin Masterflex 810 shall be grouted with the same pump but after 24 hours of injecting Meyco MP355 1K.\" |
| 35 | Polishing of Kota stone flooring/ marble flooring/ mosaic flooring etc by grinding and honing of floor using diamond abrasives to remove all minor scratches to bring an even surface. Later hardening the surface with floor polishing powders. The floor will be burnished with 1200 RPM burnishes. |
| 36 | Providing and fixing double Tubular scaffolding system using H-Frames / APS system or (cup lock type) on the exterior side upto seven story height made with 40mm dia M.S. tube 1.5m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in-charge. The elevation area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding .and as directed by the Engineer-in-charge. |
| 37 | Taking out existing CC interlocking paver blocks from footpath/ central verge,including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 38 | Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 39 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts Involved. |
| 40 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum ompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with 3nos ofstainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (a) 30 mm thick |
| 41 | Providing and fixing frame of factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(a) Frame size 50 x 70mm |
| 42 | Providing, supplying, cutting, bending to shape, welding, fabricating, hoisting, placing and fixing in position structural steel members like trusses, purlins etc. with curved profile of members using MS hollow / circular / square / rectangular tubular sections including chamfering and rounding off the edges, applying a coat of Zinc chromate primer of approved make and 2 coats of flat oil paint / synthetic enamel paint of approved colour and make, scaffolding and staging required for fabrication as well as erection complete all as per specifications, drawings and as directed by the Engineer-in-charge.Note:1.scaffolding and lifting device arrangements required as per the site condition and it is to bearranged by the contractor at his own cost. |
| 43 | Providing steel reinforcement for R.C.C. work including binding wire, cover block, straightening, cutting, bending, placing in position and binding all complete at all levelsand as per specification and as directed by the Engineer in charge. (a) Thermo-Mechanically Treated bars of grade Fe-550D or more |
| 44 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., Complete.Note: The sample Tile got approved by the Engineer in charge before procurement. |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kgNote: The sample tile got approved by the Engineer in charge before procurement. |
| 46 | Supplying of 10hp motor (electric) on rental basic for dewatering work including 50meter delivery hose, hose clamp, starter with required cable length upto 10m at all levelsand all complete as per specification and as directed by the Engineer in charge |
| 47 | Supplying of 5hp motor (electric) on rental basic for dewatering work including 50meter delivery hose, hose clamp, starter with required cable length upto 10m at all levelsand all complete as per specification and as directed by the Engineer in charge |
| 48 | Providing and Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resinper kg), including filling / grouting and finishing complete as per direction of Engineer-in- charge.Size of Tile 300x300mm / 600x600 mm |
| 49 | Providing and fixing 4 mm thick, one side decorative veneer (One side teakwood OST) conforming to IS: 1328 (type-1), for plain lining / cladding with necessary with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete .and as directed by the Engineer-in-charge. |
| 50 | Supplying & fixing mosquito mesh with Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture and supplying & fixing of powder coated aluminium frame for Windows, ventilators, Balconies for above the parapet of balcony and below baluster portion similar to the existing model. Aluminium extruded sections including main frame of 40mmx20mmx1.2mm section for all sides and sub frame 20mmx8mmx1.2mm section for horizontals, vertical withPowder coated aluminium required shade with minimum 50 microns thickness andfixed with rubber gasket wire for supporting mesh, rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required sealant. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per specification including providing approvedhinges and handle and magentic latch and making provision for fixing of fittings wherever required and as per the directions of the Engineer-in-charge.The rates for inclusive of all taxes, scaffoldings, tools & tackles labour, transport, fasteners required for fabrication, and fixing in the walls etc, |
| 51 | Providing and fixing 18 mm thick gang saw cut, mirror polished granite, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. Complete at all levels.Note: The sample Granite got approved by the Engineer in charge before procurement. (b) Area of slab over 0.50 sqm |
| 52 | Providing and fixing glazing in uPVC/aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge(a) 5.0 mm thick plain glass panes(weight not less than 12.5 kg per sqm) |
| 53 | Providing and fixing glazing in uPVC/aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (a) With pinhead colour/plain glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 54 | Providing and fixing precoated galvalume profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and the directions of engineer-in-charge |
| 55 | Cleaning and washing of chair cloth (Back rest and seat ) using chemical and vacuum cleaner and labour tools etc., and as directed by the Engineer in charge. |