Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-10-2025 | Corrigendum w.r.t. dates | Date | 23-10-2025 |
| 2 | 08-10-2025 | Corrigendum w.r.t. Pre Bid Clarification | Technical Bid | 14-10-2025 |
| Sl. No. | Item Description |
| 1 | 1. Ichapuram Municipality |
| 2 | Construction of 6.0M dia. Clear water collection well cum pump house at Proposed Head Water works nearNew Bridge in Bahudha River |
| 3 | Providing concrete for plain/reinforced concrete in open foundations using 40 mm nominal size Graded hard stone aggregate, mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH.unit 1.00 cum Nominal mix 1:3:6 |
| 4 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum M30 |
| 5 | For Base Slab |
| 6 | Well Steining |
| 7 | Pump house Columns |
| 8 | Pump House Beams |
| 9 | Floor slab |
| 10 | Top slab |
| 11 | Lintels Beam alournd |
| 12 | d) for Sunshade of 0.60mts wide and thickness of .075mts at fixed end and 0.05mts.at free end |
| 13 | Supply, delivery, fabrication and erection of Structural steelincluding cost and conveyance to work spot including all labour charges for fabrication and erection etc.,complete as directed by the departmental authorities. |
| 14 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 15 | Providing impervious course with C.M (1:3)20 mm thick and mixing with acco proof compound of 1kg per one bag of cement including cost and conveyance of all materials and labour charges for finishing and curing etc., complete as per SS (APDSS NO:903) |
| 16 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities |
| 17 | Out side |
| 18 | Inside |
| 19 | Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 20 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-30 - Item -10 of - Revised data. |
| 21 | Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 22 | Supply and delivery of \"Resilient Seated SoftSealing\" Gate Valves (Sluice Valves) with Bodyand Bonnet of Ductile Iron GGG-40/SG-400/15or GGG-50/SG-500/7 or Equivalent as perIS1865, IS:3896-2 and Wedge fully Rubber Linedwith food grade quality grade W270 gradeEPDM, Replaceable Spindle Nut without glandpacking with 3-O ring protection system on theShaft and Seals of NBR. The Valves should beVacuum tight and 100% leak proof with face toface dimensions as BS:5163 Type A/IS:14846. Allthe valves should be with fusion bondedElectrostatic Powder coating both inside andoutside (Min 250 Microns)- RAL 5005 withPocket Less Straight through body Passageconforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS- 1538 excluding all taxes, duties Drilled as per IS:1538. PN16 including Transportation |
| 23 | Supply and delivery of 600mm dia. centrifugally cast (spun) Ductile Iron tail piece fitting with required flanged (welded) ends and spigot end confirming to specification No.IS 8329/2000 with cement lining inside the pipe, out side Zinc coating including cost of fitting, VAT and other duties. The rate including transportation and conveyance to work spot and fixing in position etc., complete as per S.S and as directed by the departmental authorities for finished item of work. |
| 24 | Providing Raw Water Pumping system at River Bahuda in Ichaouram Municipality |
| 25 | Providing Clear Water Pumping system at River Bahudaby supply, delivery and erection ofVT pump set with specifications ofHead range of 30 mtrs, discharge of 144 M3/Hr for Raw Water(2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.(for pumping of clear waterfromproposed collection well-cum-pump house at New Bridge Head Works to Proposed 8MLD WTP at Santapeta) |
| 26 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 27 | Supply,delivery,Errection of 100 KVA Transformer at Collection Well cum Pump house near New Bridge. |
| 28 | Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 29 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 30 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 31 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 32 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 33 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 34 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 35 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 36 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 37 | A) Earth Electrodes |
| 38 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 39 | C) Epoxy insulators |
| 40 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 41 | Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-08781b1000KVA |
| 42 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 43 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 44 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 45 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 46 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 47 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 48 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 49 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 50 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 51 | g).3RYB Phase indication lamps with leds |
| 52 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 53 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 54 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 55 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 56 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 57 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 58 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 59 | .KWH digital meter fro lighting section |
| 60 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 61 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 62 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 63 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 64 | Supply and Laying of 3C X 120Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03460 |
| 65 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means |
| 66 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 67 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 68 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etcM25 design mix concrete |
| 69 | column footings |
| 70 | Columns1.20-0.10-0.10-0.30+1.80 |
| 71 | Plinth beam2(15+12)=54-gate3.00=51.00 |
| 72 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 73 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 74 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 75 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 76 | Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 77 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 78 | Providing 300 mm dia DI K9 Pumping mainfrom Collection well in bhauda River to WTP atSantapeta |
| 79 | Cutting open BT road surface as well as asphalt concrete upto 75mm thick including water bound mecadam and stacking of useful materials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 80 | Cutting open Cement concreteroad surface and depositing of excavatedmaterials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 81 | Providing barricading arrangement with casurina ballies as per the design duly excavating pits and its removal after the function is over including hire charges of the barricading materials a sper the schedule given by the departmental authorities complete for finished item of work_3-TIER (4 days)_BMS-W.84.F |
| 82 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m |
| 83 | A) Manual Excavation |
| 84 | B)Excavation by Machinary |
| 85 | BLD-CSTN-3-12 :RCC (M 20) Nominal Mix:using 20mm graded metal using concrete mixer including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work with nomonal reinforcement |
| 86 | supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties |
| 87 | Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 including all taxes, duties and transportation. PN1.6 Mpa - 1 A) Without By-Pass SOR Rate -2025-26 |
| 88 | 300 DN P.N.1.00 ( Sectionalisation ) |
| 89 | 200 DN P.N.1.00 ( Scour ) |
| 90 | 100mm sluice valve for air valve fixing |
| 91 | Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and inclusive of all taxes andtransportation.. PN 1.6 (MPa) -PH SOR Rate -2019-202028. SOR FOR VALVES FOR HEAVY USUAGE in WTPs, STPs |
| 92 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties ( with finishings as per Clause 13/IS 9523/2000) |
| 93 | Supply and delivery of the C.I. pipes and specials, confirming to IS:1538 -1993 of standard /non standard including cost and conveyence, packing , forwarding , transit risk etc,. complete but excluding all taxes and duties |
| 94 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings)carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 95 | B) Flanged Ends |
| 96 | ii) 200 DN |
| 97 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 98 | Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 99 | 300 DN Sluice Valve |
| 100 | 200DN Sluice Valve |
| 101 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 102 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 103 | 300 DN |
| 104 | 200 DN |
| 105 | 200 DN |
| 106 | 80 DN |
| 107 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 108 | 300 DN Sectional valve chambers |
| 109 | 200 DN scour valve chambers |
| 110 | 80 DN Air valve chambers |
| 111 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 112 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 113 | Design and Construction of 8.00 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using sand as filter media, compatible with SCADA arrangements in which all valves in filtration plant should be compatible for operation with motorized actuators integrated to SCADA , duly following relevant IS codes in the design of plant components including trial running for 90 days etc., including chlorine contact tank & consumables etc.,near santapeta existing Head water works |
| 114 | Design and Construction of Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using sand as filter media, compatible with SCADA arrangements, duly following relevant IS codes in the design of plant components including trial running for 90 days etc., including chlorine contact tank & consumables etc., complete.b) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs 59,000/- per MT(Fe 500) (BoCE rates for the month of May-2025).c) The above rates shall be increased / decreased due to increase / decrease in the cost of cement by Basic Rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of cement (Rs per Mt) at the time of preparation of estimated) The above rates shall be increased / decreased due to increase / decrease in the cost of steel by Basic Rate x { (Rs-59000)/59000} x0.2 Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.e) For Rural areas an extra allowance of 10% shall be given on basic rate.f) For components immersed in water Stain less Steel of Grade 304L shall be used. for other components 304 Grade steel shall be used.The software shall also have the features of sending messages to the mobiles of the Departmental designatories indicating Bed Low Levels, Power Supply timings, Bed Wash timings and its status, Power Supply timings and its status Grid View Table, Motor Working time and its status Grid View Table, all trigger events and schedule information and including all Snap View Reports, all Daily, Monthly, Yearly Reports, all Power Working Reports, all Power Events Information etc,. |
| 115 | Supply,delivery,Errection of 160 KVA Transformer at WTP. |
| 116 | Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 117 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 118 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 119 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 120 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 121 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 122 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 123 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 124 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 125 | A) Earth Electrodes |
| 126 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 127 | C) Epoxy insulators |
| 128 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 129 | Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-04043b 160KVA |
| 130 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 131 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 132 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 133 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 134 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 135 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 136 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 137 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 138 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 139 | g).3RYB Phase indication lamps with leds |
| 140 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 141 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 142 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 143 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 144 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 145 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 146 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 147 | .KWH digital meter fro lighting section |
| 148 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 149 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 150 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 151 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 152 | Supply and Laying of 3C X50Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03457b |
| 153 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means |
| 154 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 155 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 156 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etcM20 design mix concrete |
| 157 | column footings |
| 158 | Columns1.20-0.10-0.10-0.30+1.80 |
| 159 | Plinth beam2(15+12)=54-gate3.00=51.00 |
| 160 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 161 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 162 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 163 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 164 | Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 165 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 166 | Construction of 400KL capacity Clear water sump nearSantapeta |
| 167 | Earth work excavation for foundation in loamy and clayey soils like black cotton soils,red earth and ordinary gravel but excluding all taxes and duties. |
| 168 | Supply and filling with Dust from approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 169 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 170 | RCC in M 30Grade design mix using 20mm down graded SS-5 HBG m/c metal , coarse and fine aggregates conforming to IS: 383,as permix design for Fair degree of quality control) including cost and conveyance of all materials, machinery,all labour charges , machine mixing, vibration, curingand all incidental & operational chargesetc. complete conforming to standard specification but excluding cost & conveyance of reinforcement and its fabrication charges. |
| 171 | FloorSlab |
| 172 | Sidewalls of Sump 250mm thick at top and 450mm thick at bottom |
| 173 | Columns |
| 174 | Roof Beams |
| 175 | Roof slab 150mm thick |
| 176 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 177 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 178 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours out side |
| 179 | Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 |
| 180 | Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes. 24x24 HD 20 |
| 181 | Supplying & fixing of pre Cast R.C.C.ladders |
| 182 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. RBR-SPST-7 |
| 183 | Manufacture, supply and delivery of Ductile Iron pipes and fittings (spls). Conforming to IS No.7181/1986, 5531/1988,3950/1979confirming to IS no.8794/1988 at site of work anywhere in A.P. including loading, unloading, transportation to site of work stack at site transit risk and package, including all taxes |
| 184 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4 includingElectrostatic powder coating both inside and outside etc complete |
| 185 | 350 mm dia Sluice Valve |
| 186 | 150 mm dia Sluice Valve |
| 187 | Labour charges for lowering and keeping in position of C.I. Sluice valves, reflux valves and scour valves. |
| 188 | 350 mm dia Sluice Valve |
| 189 | 150mm dia Sluice Valve |
| 190 | Jointing the CI/DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with waterwith a water lead upto 500m and testing to required pressure complete. |
| 191 | 350 mm dia flanged joints |
| 192 | 150mm diaflanged joints |
| 193 | Construction of master pump house near santapeta |
| 194 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side |
| 195 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 196 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 197 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 198 | Column footings |
| 199 | Pedastal |
| 200 | for Pumps bases |
| 201 | Columns |
| 202 | Plinth beam |
| 203 | Lintles |
| 204 | Roof Beams |
| 205 | Roof slab |
| 206 | Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 207 | Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 208 | Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 209 | Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 210 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 211 | Out side |
| 212 | Inside |
| 213 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 214 | Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface to required smoothness and slopes and thread lining including cost of all materials like cement, metal, sand and water etc., complete, including seigniorage charges, etc., complete for finished item of work, |
| 215 | Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 216 | Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work BLD-CSTN-8-25 |
| 217 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-30 |
| 218 | Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 219 | Supply, delivery, and erection of Clear water Horizontal split casing CentrifugalPumpsetshaving various capacities ofdischarge and head (As per separate estimate) of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformet to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete at Santapeta Head Works to Service Reservoirs of Zone-I ,II,III&IV |
| 220 | Supply, delivery and erection ofHSC pump set with specifications ofHead range &, discharge as followWaterPumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 221 | Pump sets with a discharge of 15lps against head of 59m to Zone-I Rathakanna GLSR |
| 222 | Pump sets with a discharge of 34lps against head of 50m to Zone-II Bellupada GLSR |
| 223 | Pump sets with a discharge of 34lps against head of 34m to Zone-III Lalapeta ELSR |
| 224 | Pump sets with a discharge of 27lps against head of 60m to Zone-IV Purusothapuram GLSR |
| 225 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.forLalapeta ELSR ,Purusothapuram GLSR |
| 226 | Pump sets with a discharge of 15lps against head of 59m to Zone-I Rathakanna GLSR |
| 227 | Pump sets with a discharge of 34lps against head of 50m to Zone-II Bellupada GLSR |
| 228 | Pump sets with a discharge of 34lps against head of 34m to Zone-III Lalapeta ELSR |
| 229 | Pump sets with a discharge of 27lps against head of 60m to Zone-IV Purusothapuram GLSR |
| 230 | Providing 200 mm dia DI K9 Pumping mainfrom sump near Santapeta to Proposed 800 GLSR at Bellupada 1730.Rmt |
| 231 | Cutting open BT road surface as well as asphalt concrete upto 75mm thick including water bound mecadam and stacking of useful materials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 232 | Cutting open Cement concreteroad surface and depositing of excavatedmaterials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 233 | Providing barricading arrangement with casurina ballies as per the design duly excavating pits and its removal after the function is over including hire charges of the barricading materials a sper the schedule given by the departmental authorities complete for finished item of work_3-TIER (4 days)_BMS-W.84.F |
| 234 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m |
| 235 | A)By mannual |
| 236 | B)Excavation by Machinary |
| 237 | Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 238 | Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties |
| 239 | Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties andincluding transportation. |
| 240 | 200 DN P.N.1.60 ( Sectionalisation ) |
| 241 | 150 DN P.N.1.60 ( Scour ) |
| 242 | upply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and inclusive of all taxes andtransportation.. PN 1.6 (MPa) |
| 243 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties ( with finishings as per Clause 13/IS 9523/2000) |
| 244 | Supply and delivery of the C.I. pipes and specials, confirming to IS:1538 -1993 of standard /non standard including cost and conveyence, packing , forwarding , transit risk etc,. complete but excluding all taxes and duties |
| 245 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings)carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 246 | A) 200 DN Socket / Spigot Ends |
| 247 | B) Flanged Ends |
| 248 | 150 DN 2.0m Long C.I. D/F Pipes |
| 249 | 150 DN Semi Circular Bend |
| 250 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 251 | Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 252 | 200 DN Sluice Valve |
| 253 | 150 DN Sluice Valve |
| 254 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 255 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 256 | 200 DN |
| 257 | 150 DN |
| 258 | 150 DN |
| 259 | 80 DN |
| 260 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 261 | 200 DN Sectional valve chambers |
| 262 | 150 DN scour valve chambers |
| 263 | 80 DN Air valve chambers |
| 264 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 265 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 266 | Construction of 800 KL Capacity GLSR at Bellupada for Zone-II |
| 267 | Earth work excavation for foundation in loamy and clayey soils like black cotton soils,red earth and ordinary gravel but excluding all taxes and duties. |
| 268 | Supply and filling with Dust from approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 269 | Providing and laying base concrete using Plain Cement Concrete (1:4:8)prop in 40mm grade nominal size HBG machine crushed metal (1 Cement : 3 Sand : 6 Coarse aggregate) including cost and conveyance of all meterials, seignorage charges, labour charges,mixing etc complete |
| 270 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30 |
| 271 | FloorSlab |
| 272 | Sidewalls of Sump 250mm thick at top and 450mm thick at bottom |
| 273 | Columns |
| 274 | Roof Beams |
| 275 | Roof slab 150mm thick |
| 276 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 277 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 278 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours) completefor finished item of work |
| 279 | Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 |
| 280 | Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes. 24x24 HD 20 |
| 281 | Supplying & fixing of pre Cast R.C.C.ladders |
| 282 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. RBR-SPST-7 |
| 283 | Manufacture, supply and delivery of Ductile Iron pipes and fittings (spls). Conforming to IS No.7181/1986, 5531/1988,3950/1979confirming to IS no.8794/1988 at site of work anywhere in A.P. including loading, unloading, transportation to site of work stack at site transit risk and package, including all taxes |
| 284 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4 includingElectrostatic powder coating both inside and outside etc complete |
| 285 | 350 mm dia Sluice Valve |
| 286 | 150 mm dia Sluice Valve |
| 287 | Labour charges for lowering and keeping in position of C.I. Sluice valves, reflux valves and scour valves. |
| 288 | 350 mm dia Sluice Valve |
| 289 | 150mm dia Sluice Valve |
| 290 | Jointing the CI/DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with waterwith a water lead upto 500m and testing to required pressure complete. |
| 291 | 350 mm dia flanged joints |
| 292 | 150mm diaflanged joints |
| 293 | Construction of 250 KL Capacity GLSR at Purusothapuram for Zone-IV |
| 294 | Earth work excavation for foundation in loamy and clayey soils like black cotton soils,red earth and ordinary gravel but excluding all taxes and duties. |
| 295 | Supply and filling with Dust from approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 296 | Providing and laying base concrete using Plain Cement Concrete (1:4:8)prop in 40mm grade nominal size HBG machine crushed metal (1 Cement : 3 Sand : 6 Coarse aggregate) including cost and conveyance of all meterials, seignorage charges, labour charges,mixing etc complete |
| 297 | RCC in M 30Grade design mix using 20mm down graded SS-5 HBG m/c metal , coarse and fine aggregates conforming to IS: 383,as permix design for Fair degree of quality control) including cost and conveyance of all materials, machinery,all labour charges , machine mixing, vibration, curingand all incidental & operational chargesetc. complete conforming to standard specification but excluding cost & conveyance of reinforcement and its fabrication charges. |
| 298 | FloorSlab |
| 299 | Sidewalls of Sump 250mm thick at top and 450mm thick at bottom |
| 300 | Columns |
| 301 | Roof Beams |
| 302 | Roof slab 150mm thick |
| 303 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 304 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 305 | Whiting withsuryacem intwo coats including cost & conveyance of all materials, labour charges etc, completefor finished item of work |
| 306 | Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 |
| 307 | Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes. 24x24 HD 20 |
| 308 | Supplying & fixing of pre Cast R.C.C.ladders |
| 309 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. RBR-SPST-7 |
| 310 | Manufacture, supply and delivery of Ductile Iron pipes and fittings (spls). Conforming to IS No.7181/1986, 5531/1988,3950/1979confirming to IS no.8794/1988 at site of work anywhere in A.P. including loading, unloading, transportation to site of work stack at site transit risk and package, including all taxes |
| 311 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4 includingElectrostatic powder coating both inside and outside etc complete |
| 312 | 200 mm dia Sluice Valve |
| 313 | 150 mm dia Sluice Valve |
| 314 | Labour charges for lowering and keeping in position of C.I. Sluice valves, reflux valves and scour valves. |
| 315 | 200 mm dia Sluice Valve |
| 316 | 150mm dia Sluice Valve |
| 317 | Jointing the CI/DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with waterwith a water lead upto 500m and testing to required pressure complete. |
| 318 | 200 mm dia flanged joints |
| 319 | 150mm diaflanged joints |
| 320 | Construction of 250 KL Capacity GLSR at Rathakanna for Zone-I |
| 321 | Earth work excavation for foundation in loamy and clayey soils like black cotton soils,red earth and ordinary gravel but excluding all taxes and duties. |
| 322 | Supply and filling with Dust from approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 323 | Providing and laying base concrete using Plain Cement Concrete (1:4:8)prop in 40mm grade nominal size HBG machine crushed metal (1 Cement : 3 Sand : 6 Coarse aggregate) including cost and conveyance of all meterials, seignorage charges, labour charges,mixing etc complete |
| 324 | RCC in M 30Grade design mix using 20mm down graded SS-5 HBG m/c metal , coarse and fine aggregates conforming to IS: 383,as permix design for Fair degree of quality control) including cost and conveyance of all materials, machinery,all labour charges , machine mixing, vibration, curingand all incidental & operational chargesetc. complete conforming to standard specification but excluding cost & conveyance of reinforcement and its fabrication charges. |
| 325 | FloorSlab |
| 326 | Sidewalls of Sump 250mm thick at top and 350mm thick at bottom |
| 327 | Columns |
| 328 | Roof Beams |
| 329 | Roof slab 150mm thick |
| 330 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 331 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 332 | Whiting withsuryacem intwo coats including cost & conveyance of all materials, labour charges etc, completefor finished item of work |
| 333 | Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 |
| 334 | Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes. 24x24 HD 20 |
| 335 | Supplying & fixing of pre Cast R.C.C.ladders |
| 336 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. RBR-SPST-7 |
| 337 | Manufacture, supply and delivery of Ductile Iron pipes and fittings (spls). Conforming to IS No.7181/1986, 5531/1988,3950/1979confirming to IS no.8794/1988 at site of work anywhere in A.P. including loading, unloading, transportation to site of work stack at site transit risk and package, including all taxes |
| 338 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4 includingElectrostatic powder coating both inside and outside etc complete |
| 339 | 200 mm dia Sluice Valve |
| 340 | 150 mm dia Sluice Valve |
| 341 | Labour charges for lowering and keeping in position of C.I. Sluice valves, reflux valves and scour valves. |
| 342 | 200 mm dia Sluice Valve |
| 343 | 150mm dia Sluice Valve |
| 344 | Jointing the CI/DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with waterwith a water lead upto 500m and testing to required pressure complete. |
| 345 | 200 mm dia flanged joints |
| 346 | 150mm diaflanged joints |
| 347 | Providing 200 mm dia DI K9 Pumping mainfrom Existing 60KL GLSR at Santapeta to Existing 500KL GLSR at Purusothapuram5952.00Rmt |
| 348 | Cutting open BT road surface as well as asphalt concrete upto 75mm thick including water bound mecadam and stacking of useful materials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 349 | Cutting open Cement concreteroad surface and depositing of excavatedmaterials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 350 | Providing barricading arrangement with casurina ballies as per the design duly excavating pits and its removal after the function is over including hire charges of the barricading materials a sper the schedule given by the departmental authorities complete for finished item of work_3-TIER (4 days)_BMS-W.84.F |
| 351 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m |
| 352 | A)By mannual |
| 353 | B)Excavation by Machinary |
| 354 | Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 355 | Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties andincluding transportation. |
| 356 | 200 DN P.N.1.60 ( Sectionalisation ) |
| 357 | 150 DN P.N.1.60 ( Scour ) |
| 358 | upply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and inclusive of all taxes andtransportation.. PN 1.6 (MPa) |
| 359 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties ( with finishings as per Clause 13/IS 9523/2000) |
| 360 | Supply and delivery of the C.I. pipes and specials, confirming to IS:1538 -1993 of standard /non standard including cost and conveyence, packing , forwarding , transit risk etc,. complete but excluding all taxes and duties |
| 361 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings)carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 362 | A) 200 DN Socket / Spigot Ends |
| 363 | B) Flanged Ends |
| 364 | 150 DN 2.0m Long C.I. D/F Pipes |
| 365 | 150 DN Semi Circular Bend |
| 366 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 367 | Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 368 | 200 DN Sluice Valve |
| 369 | 150 DN Sluice Valve |
| 370 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 371 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 372 | 200 DN |
| 373 | 150 DN |
| 374 | 150 DN |
| 375 | 80 DN |
| 376 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 377 | 200 DN Sectional valve chambers |
| 378 | 150 DN scour valve chambers |
| 379 | 80 DN Air valve chambers |
| 380 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 381 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 382 | Providing 150 mm dia DI K9 Pumping main from existing GLSR at Rathakanna to proposed 250 KL Capacity for Zone-I |
| 383 | Cutting open BT road surface as well as asphalt concrete upto 75mm thick including water bound mecadam and stacking of useful materials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 384 | Cutting open Cement concreteroad surface and depositing of excavatedmaterials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 385 | Providing barricading arrangement with casurina ballies as per the design duly excavating pits and its removal after the function is over including hire charges of the barricading materials a sper the schedule given by the departmental authorities complete for finished item of work_3-TIER (4 days)_BMS-W.84.F |
| 386 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m |
| 387 | A)By mannual |
| 388 | B)Excavation by Machinary |
| 389 | Plain Cement Concrete 1:3:6using 40mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties |
| 390 | Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties |
| 391 | Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 including all taxes, duties and transportation. PN1.6 Mpa - 1 A) Without By-Pass SOR Rate -2025-26 |
| 392 | 150 DN P.N.1.60 ( Sectionalisation ) |
| 393 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties ( with finishings as per Clause 13/IS 9523/2000) |
| 394 | Supply and delivery of the C.I. pipes and specials, confirming to IS:1538 -1993 of standard /non standard including cost and conveyence, packing , forwarding , transit risk etc,. complete but excluding all taxes and duties |
| 395 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings)carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 396 | A) 150 DN Socket / Spigot Ends |
| 397 | B) Flanged Ends |
| 398 | 150 DN 2.0m Long C.I. D/F Pipes |
| 399 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 400 | Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 401 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 402 | 150 DN |
| 403 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 404 | 150 DN Sectional valve chambers |
| 405 | 150 DN scour valve chambers |
| 406 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 407 | Supply,delivery,Errection of 315 KVA Transformer at Santapeta near proposed WTP |
| 408 | Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 409 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 410 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 411 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 412 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 413 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 414 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 415 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 416 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 417 | A) Earth Electrodes |
| 418 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 419 | C) Epoxy insulators |
| 420 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 421 | Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-04045D315 KVA |
| 422 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 423 | LT panel |
| 424 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 425 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 426 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 427 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 428 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 429 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 430 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 431 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 432 | g).3RYB Phase indication lamps with leds |
| 433 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 434 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 435 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 436 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 437 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 438 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 439 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 440 | .KWH digital meter fro lighting section |
| 441 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 442 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 443 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 444 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 445 | Supply and Laying of 3C X 70Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03458 |
| 446 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means |
| 447 | column footings |
| 448 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 449 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 450 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etcM20 design mix concrete |
| 451 | column footings |
| 452 | Columns1.20-0.10-0.10-0.30+1.80 |
| 453 | Plinth beam2(15+12)=54-gate3.00=51.00 |
| 454 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 455 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 456 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 457 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 458 | Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 459 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 460 | Construction of Subsurface Dyke in the River bed of Bahuda |
| 461 | Earthwork in excavation for clay blanket as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width (RBR-FNDN-1) including refilling of the trench |
| 462 | Up To 3.00 mts. |
| 463 | Cut off wall key |
| 464 | Shoring and strutting for foundations as per Specification for 1.5 mts height alround the Foundation of the Dyke |
| 465 | Providing Barricading and Lighting Arrangements for watch ward alround the Foundations of the Dyke |
| 466 | Providing Plain cement concrete 1:4:8 using 40 mm metal with concrete mixer upto plinth level as approved by the department including cost and conveyance of all materials to site, machine mixing of concrete, all lifts, leads, delifts, centering, laying in position, vibrating, compacting, curing, removal of centering, all labour charges, tools and plants, and all other incidental and operational charges etc., complete as per specifications,drawings and as directed by the Engineer - in - Chargefor Foundations of the Dyke |
| 467 | ProvidingVRCC M30Mix Using20mm size grade nominal size HBG machine crushed metal including cost and conveyance of all meterials, seignorage charges, labour charges,mixing etc complete |
| 468 | Foundation raft of Dyke Structure vertical (0.23+0.30)/2 |
| 469 | Key Vertical Walls as 500mm thick at bottom and 300mm thick at bottom |
| 470 | Base slabs |
| 471 | Providing Plain cement concrete M15nominal mix as approved by the department using40 mmhard granite machine crushed metal including cost and conveyance of all materials to site, machine mixing of concrete, all lifts, leads, delifts, centering, laying in position, vibrating, compacting, curing, removal of centering, all labour charges, tools and plants, and all other incidental and operational charges etc., complete as per specifications,drawings and as directed by the Engineer - in - Charge |
| 472 | Supply and Delivery of HYSD Fe 415 grade reinforcement steel including cost and conveyance to site and labour charges, cutting, bending, fabrication, bindingof reinforcementincluding cost of binding wire etc. complete as per SS but Excluding all taxes@ 120Kg / Cum |
| 473 | Levelling of the Excavated earth on Down Stream side |
| 474 | Providing 300mm thick Dry Stone packing with 450mm size for appron |
| 475 | Construction of Compound wall at Head works |
| 476 | Constuction of compound wall with the following specifications1. Earth work excavation for column footings ,providing sand bed in foundations,providing CC 1:4:8 for foundations,VRCCM 20 for column footings,plinth beams,columns,Brick work in CM 1:6 , Plastering CM 1:5, Snowcem painting, etc complete |
| 477 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 478 | Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 479 | Construction of watchmen quarters at Head works,WTP and 4 service reservoirs-6Nos. |
| 480 | Earthwork excavation and depositing on bank with an initial lead of 10 meters and initial lift of 2 meters in case of head lead only in loamy and clayee soils like Black cotton Soils, red earth and ordinary gravel . |
| 481 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 482 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 483 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 484 | For1st footing |
| 485 | Columns (BGL) |
| 486 | Plinth beam |
| 487 | Lintle beamsWindows |
| 488 | Roof Beams |
| 489 | Roof slab150 mm |
| 490 | Sunshades W |
| 491 | Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 492 | Cement plasteringusing opc in cm(1:4) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 493 | Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 494 | Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work |
| 495 | Colourwashing two coats Using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 496 | Out side |
| 497 | Insode |
| 498 | Supply delivary and fixing RCC Jalles 50 mm thick includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 499 | Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 500 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 501 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 502 | Providing PCC (1:4:8)using40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 503 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 504 | Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 505 | Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 506 | Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor flooring |
| 507 | Construction of SCADA Control Room at Municipal office |
| 508 | Earthwork excavation by Manuallyin all types of soilsfor structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification |
| 509 | Supply and filling with dustcomplying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification |
| 510 | Laying Cement concrete (1:4:8)using 40mm nominal size HBG metal M/C including cost and conveyance of all materials from approved quarry, machine mixing, vibrating, laying, levelling, ramming, curing and labour charges etc., complete. |
| 511 | Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification |
| 512 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum |
| 513 | Footings |
| 514 | Pedastals around Columns |
| 515 | Columns Up to plinth |
| 516 | Plinth Beams |
| 517 | Columns |
| 518 | Beams |
| 519 | Lintels |
| 520 | Sunshades |
| 521 | Staircase |
| 522 | RCC Slab 150mm thick |
| 523 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT)steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification |
| 524 | Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of workand as per Technical Specification |
| 525 | Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification- Outside |
| 526 | Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification.- Inside |
| 527 | Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification- Ceiling |
| 528 | Flooring with ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials as per the technical specification |
| 529 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification out side |
| 530 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification inside |
| 531 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification- Ceiling |
| 532 | Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 533 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-30 - Item -10 of - Revised data. |
| 534 | Supply of 2.0TR, 5 Star capable of delivering not lessthan 21600 BTU/hr and above with operating onrefrigerant R-410A / R-32Makes: As per list of recommended brands ascategory II. INVERTER Model Cool type split AC unit with highwall mounted Single Split indoor unit and outdoor condensing unitHermetically sealed compressor suitable for operation on 230V, 50Hz,1Phase AC supply capable of performing Heat cool dehumidifying aircirculating and filtering with cooling and condensing units with 3 mts ofcopper piping, insulation kit and 4 mts of 4 core copper flexible chordwith cordless remote control etc., dual barrier coating in order to protectcoil form oxidation with copper condenser.MAT-05516 |
| 535 | Provision for Environmental Management Plan during execcution period |
| 536 | Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 537 | Noiselevel(5 Monitoringstation)onceinamonthforthree seasonsduring the constructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 538 | Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 539 | Providing Distribution System in Zones I to IV of Ichapuram Municipality including higher dia. HDPE casing pipe at drain cross provision |
| 540 | Cutting open BT road surface as well as asphalt concrete upto 75mm thick including water bound mecadam and stacking of useful materials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 541 | Cutting open Cement concreteroad surface and depositing of excavatedmaterials including all labour charges and all incidental and operational charges etc., complete for pipe line works. |
| 542 | Providing barricading arrangement with casurina ballies as per the design duly excavating pits and its removal after the function is over including hire charges of the barricading materials a sper the schedule given by the departmental authorities complete for finished item of work_3-TIER (4 days)_BMS-W.84.F |
| 543 | Earthworkexcavationby Machinery in ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m |
| 544 | A) Manual Excavation |
| 545 | B)Excavation by Machinary |
| 546 | Manufacture and supply of the following HDPE PE 100 grade pipes conforming to IS 4894-1995 including transportation to any where in Andhra Pradesh including ST, CED and other duties etc. complete. |
| 547 | 110HDPE |
| 548 | 160HDPE |
| 549 | 200HDPE |
| 550 | 250HDPE |
| 551 | 280HDPE |
| 552 | 315HDPE |
| 553 | Supply and delivery of centrifugally cast (spun) DI pressure pipes (K7) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties |
| 554 | 300MM |
| 555 | 350 MM |
| 556 | 400MM |
| 557 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings)carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 558 | 300MM |
| 559 | 350 MM |
| 560 | 400MM |
| 561 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 562 | 400MM |
| 563 | 350 MM |
| 564 | 300MM |
| 565 | Laying and jointing of HDPE pipes by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipe to the required pressure. |
| 566 | 355 mm dia PN 6 |
| 567 | 110HDPE |
| 568 | 160HDPE |
| 569 | 200HDPE |
| 570 | 250HDPE |
| 571 | 280HDPE |
| 572 | 315HDPE |
| 573 | Manufacture and supply of the following HDPE fittings conforming to IS 4894-1995 including transportation to any where in Andhra Pradesh excluding ST, CED and other duties etc. complete. |
| 574 | TEE\"s |
| 575 | 355 mm dia PN 6 |
| 576 | 110HDPE |
| 577 | 160HDPE |
| 578 | 200HDPE |
| 579 | 250HDPE |
| 580 | 280HDPE |
| 581 | 315HDPE |
| 582 | Reducers |
| 583 | 355 mm dia PN 6 |
| 584 | 110x125 |
| 585 | 160x180 |
| 586 | 200x225 |
| 587 | 250x280 |
| 588 | 280x315 |
| 589 | 315x355 |
| 590 | Bends |
| 591 | 355 mm dia PN 6 |
| 592 | 110HDPE |
| 593 | 160HDPE |
| 594 | 200HDPE |
| 595 | 250HDPE |
| 596 | 280HDPE |
| 597 | 315HDPE |
| 598 | Pipe end long neck |
| 599 | 355 mm dia PN 6 |
| 600 | 110HDPE |
| 601 | 160HDPE |
| 602 | 200HDPE |
| 603 | 250HDPE |
| 604 | 280HDPE |
| 605 | 315HDPE |
| 606 | M.S. Flanges |
| 607 | 355 mm dia PN 6 |
| 608 | 110HDPE |
| 609 | 160HDPE |
| 610 | 200HDPE |
| 611 | 250HDPE |
| 612 | 280HDPE |
| 613 | 315HDPE |
| 614 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4.All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. |
| 615 | 300 mm dia |
| 616 | 200 mm dia |
| 617 | 150 mm dia |
| 618 | 100 mm dia |
| 619 | for scour valves 100mm |
| 620 | Lowering, laying and keeping in position of CI sluice reflux valves inthe excavated trenches true to alignment and gradient including all charges as per SS and as directed by the department. |
| 621 | 300 mm dia |
| 622 | 200 mm dia |
| 623 | 150 mm dia |
| 624 | 100 mm dia |
| 625 | Supply and delivery of the C.I. pipes and specials, confirming to IS:1538 -1993 of standard /non standard including cost and conveyence, packing , forwarding , transit risk etc,. complete but excluding all taxes and duties |
| 626 | Jointing the CI pipes and specials with double flanged ends using bolts, nuts, and rubber insertion including all labour charges and other charges as per SS asd as directed by the department. |
| 627 | 300 mm dia |
| 628 | 200 mm dia |
| 629 | 150 mm dia |
| 630 | Control valves |
| 631 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 632 | for 300mm diavalves |
| 633 | for 200mm diavalves |
| 634 | for 150mm diavalves |
| 635 | for 100mm diavalves |
| 636 | Scour valves |
| 637 | Collection, supply and filling of stone dust/quarry spall to work site including cost and conveyance of all materials and all labour charges for flling etc., complete. |
| 638 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 639 | Providing House Service Connections |
| 640 | Providing house service connections at house holds side in earthern roads |
| 641 | Providing house service connections at other side in earthern roads |
| 642 | Providing house service connections at otherside in BT &CCroads |
| 643 | Providing house service connections at HHside in BT &CCroads |
| 644 | Providing 24 x 7 Water Supply ::DMA Management ::in Ichapuram municipality |
| 645 | 24 x 7 Water Supply ::DMA Management :: |
| 646 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 647 | Supply and deliveryof Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 648 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 649 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 650 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 651 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 652 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 653 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 654 | Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 655 | Providing, Installing and satisfactory field testing of Self Powered Presuure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 656 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 657 | ProvidingAMI Water Meter Management in Ichapuram municipality |
| 658 | Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-A. |
| 659 | Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoTin every 24 Hours without fail through the provider registered inDOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication)The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warrantiesand submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-B |
| 660 | Under DMA-1&2 under 800 KL ELSR atBellapadu in Zone-II with above specifications |
| 661 | Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer. |
| 662 | Supply distrubution and fixing, installation of Flowmeters, Motorised Valves, Level Indicators including Supervisory Control and Data Acuasation System (SCADA) for controlling and monitoringin Ichapuram municipality |
| 663 | Instrumantation and Automation of the Pumping System: |
| 664 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 665 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 666 | Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facilitycomplete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties |
| 667 | Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer |
| 668 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 669 | 300MM Dia Above Specification. |
| 670 | Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 671 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 672 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 673 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 674 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 675 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 676 | Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 677 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 678 | 150 MM Dia Above Specification. |
| 679 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 680 | 150 MM Dia Above Specification. |
| 681 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 682 | 150 MM Dia Above Specification. |
| 683 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 684 | 100MM Dia Above Specification. |
| 685 | 150 MM Dia Above Specification. |
| 686 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 687 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 688 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 689 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 690 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 691 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 692 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 693 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 694 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 695 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 696 | Local SCADA Control Sation: |
| 697 | Establishment of HARDWARE for Individual Local Control Station at Individual ULB :: |
| 698 | Development of Softwares for Individual Local Control Station at Individual ULB :: |
| 699 | OPEX-Manning, Operation and Maintenance of Water Supply Improvement Scheme in Ichapuram Municipality |
| 700 | Personal required for operating Intake/Offtake well/Pump houses |
| 701 | Operator |
| 702 | Watch man |
| 703 | Personal required at operating Raw water rising mains |
| 704 | Operator |
| 705 | Fitter/Helper |
| 706 | Electrician /Mechanic |
| 707 | Watch man |
| 708 | Personal required at operating Service reservoirs |
| 709 | Watch man |
| 710 | Personal required at operating Distribution system |
| 711 | Fitter/Helper |
| 712 | Consumables for 7 years |
| 713 | A) Chlorine gas for Disinfection @ 3 mg/Lt |
| 714 | Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a dis |
| 715 | B) Alumino -Ferric (Alum) @ 20 mg/Lt |
| 716 | Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit |
| 717 | Repairs to pumpsets & Water pipe lines(2 years after execution period) |
| 718 | i) Replacement of bearings of pumpsets |
| 719 | ii) Replacement of sleeves |
| 720 | iv) Raw Water Motors |
| 721 | Clear Water Motors |
| 722 | iv)Replacement of glands of sluice valves |
| 723 | v) Replacements of balls of Air valves |
| 724 | vi) Greease |
| 725 | vii) Gland Packing |
| 726 | Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete |
| 727 | 315 mm HDPE Pipes |
| 728 | 280 mm HDPE Pipes |
| 729 | 250 mm HDPE Pipes |
| 730 | 200 mm HDPE Pipes |
| 731 | 160 mm HDPE Pipes |
| 732 | 110 mm HDPE Pipes |
| 733 | Environmental Management Plan during maintanance period |
| 734 | Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 735 | Noiselevel(5Monitoringstation)onceinamonthforthree seasonsduring the constructionperiodat intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 736 | Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 737 | Compensatory plantation andthree years maintenance (Compensatory afforestation ratio is 1:5) |
| 738 | Sprinkling of wateronce in a day fortwo years (excluding rainy days):500 days @ Rs.1000/trip |
| 739 | OPERATION & MAINTENANCE COST - CENTRAL SCADA at CIRCLE LEVELfor Seven Years including two years defect liability period |
| 740 | To monitor all issues related to both operation & service |
| 741 | To monitor all meters location through SCADA station and give feedback to the service engineers. |
| 742 | With assistance of the DBA, preparation of daily reports, monthly billing, correspondence with consumers and also co-ordinate with the Officials for obtaining of required information when ever asks. |
| 743 | To assist the entire team, dispatches and also maintain SCADA station clean and neat |
| 744 | Interconnection for Data receive station from all Local Contol RTU panels. |
| 745 | Data storage and reporting system for view through WEB and Mobile networks |
| 746 | for day to day Operations & Reporting |
| 747 | OPERATION & MAINTENANCE COST - LOCAL SCADA at Ichapuram Municipalityfor Seven Years including two years defect liability period |
| 748 | To asist to attend the service calls by the seniour service engineer |
| 749 | With assistance of the DBA, preparation of daily reports, monthly billing, correspondence with consumers and also co-ordinate with the GVMC Officials for obtaining of required information when ever asks. |
| 750 | To assist the entire team, dispatches and also maintain SCADA station clean and neat |
| 751 | To attend service calls and break down on 24 x 7 |
| 752 | Replacement of necessary servicable materials(Reagents) for Chlorine Analysers*Each Reagent bottle willwork for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. |
| 753 | Replacement of necessary tranducers for PH analysers |
| 754 | Replacement of necessary tranducers for Turbidity analysers |
| 755 | Interconnection for Data receive station from all Local Contol RTU panels. |
| 756 | Data transfer from RTU control panels |
| 757 | for day to day Operations & Reporting |
| 758 | Amadalavalasa Municipality |
| 759 | Construction of Infiltration well No.1 & 2 of 4 m Dia in VamsadharaRiver at Alamaji peta near the existing Head Water works. |
| 760 | Supply, delivery, fabrication and erection of cutting toe for well curb with ISA 100x100x10mm including cost and conveyance to work spot including all labour charges for fabrication and erection etc.,complete as directed by the departmental authorities. |
| 761 | Earthwork in excavation as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH |
| 762 | Well sinking in sandy and other loose soils under water either by manual labour, divers, or dredgers, weighing the top of steining to assist sinking etc., including dewatering and other incidental charges such as hire charges for mechanical equipment etc,complete for an internal dia of 4.00mts |
| 763 | a) Up to 2.00mts depth |
| 764 | b) 2.00mts to 4.00mts depth |
| 765 | c) 4.00mts to 6.00mts depth |
| 766 | d) 6.00mts to 8.00mts depth |
| 767 | e) 8.00mts to 8.70mts depth |
| 768 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete with all de-lift charges but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) |
| 769 | Well Curb |
| 770 | Side walls (Well Steining) |
| 771 | Well top cover slab 200 mm thick. |
| 772 | Supply, delivery and fabrication of HYSD Steel of various sizes including cutting, bending, tying of grills with binding wire, fabrication charges and placing grills in position including cost and conveyance of all materials including cost of binding wire and all labour charge etc., complete as per S.S and directed by the departmental authorities |
| 773 | Providing invert filter media with following sizes of metal including cost of material, laying charges etc., complete |
| 774 | 40 mm Metal |
| 775 | 12 to 20 mm metal |
| 776 | Supply and fixing of 32 mm dia PVC / 10 Kg / Sq. Cm pipe for weep holes @ 300 mm C/C staggered spacing including cost and conveyance of all materials and all labour charge for fixing in staining wall etc., complete as per S.S and directed by the departmental authorities |
| 777 | Construction of 600 mm dia Infiltration gallery from Infiltration Well No.1 to 2 & 2to collection well cum Pump House in Vamsadhara River near the existing Head Water works at Alamajipeta. |
| 778 | Excavation of trenches for infiltration galleries and connecting mains in all soils under water including all leads, lifts, shoring, strutting, bailing out water and removal of shoring and strutting materials after completion of pipe line work. |
| 779 | a) 0.00 to 1.00 m depth |
| 780 | b) 1.00 to 2.00m deep |
| 781 | c) 2.00 to 5.00mdeep |
| 782 | d) 5.00 to 6.00 m deep |
| 783 | e) 6.00 to 7.00 m deep |
| 784 | Manufacture, supply and delivery of 600mm dia. S/S RCC NP3 class perforated pipes for Infiltration gallery including cost and conveyance to work spot and handling charges providing perforated holes including all taxes and duties etc., complete as per S.S |
| 785 | Lowering, laying and jointing of 600mm dia. RCC perforated pipes of NP3 class inclusive of bailing out water and jointing with cement fillets, and all other incidental charges for infiltration gallery inclusive of bailing out water by pumping to keep the trench reasonably dry to fecilate the work excluding cost of perforated pipes and collars. |
| 786 | Providing and construction of transition cum filter media using approved or recommended material i.e., 230mm thick 230mm thick 40-20mm C.A, 230mm thick 20-12mm C.A, 230mm thick 12-6mm C.A, 230mm thick Coarse sand and 400mm thick fine sand satisfying the filter criteria including machinery, labour, laying each layer to required slope, compaction etc., complete with all extra leads and de lifts |
| 787 | 40 mm to 20mm size Coarse aggregate |
| 788 | 20 mm to 12 mm size Coarse aggregate |
| 789 | 12 mm to 6 mm size Coarse aggregate |
| 790 | Coarse sand |
| 791 | Fine sand |
| 792 | Construction of 6.00 mts dia RCC collection well cum Pump House in Vamsadhara River near the existing Head Water works at Alamajipeta. |
| 793 | Supply, delivery, fabrication and erection of cutting toe for well curb with ISA 150x150x12mm including cost and conveyance to work spot including all labour charges for fabrication and erection etc.,complete as directed by the departmental authorities. |
| 794 | Earthwork in excavation as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH |
| 795 | Well sinking in sandy and other loose soils under water either by manual labour, divers, or dredgers, weighing the top of steining to assist sinking etc., including dewatering and other incidental charges such as hire charges for mechanical equipment etc,complete for an internal dia of 6.00mts |
| 796 | a) Up to 2.00mts depth |
| 797 | b) 2.00mts to 4.00mts depth |
| 798 | c) 4.00mts to 6.00mts depth |
| 799 | d) 6.00mts to 8.00mts depth |
| 800 | e) 8.00mts to 10.00mts depth |
| 801 | e) 10.00mts to 11.00mts depth |
| 802 | e) 11.00mts to 11.80mts depth |
| 803 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete with all de-lift charges but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) |
| 804 | Well Curb |
| 805 | Side walls (Well Steining) - Well 1 |
| 806 | Side walls (Well Steining) - Well 1 |
| 807 | Well top cover slab 200 mm thick. |
| 808 | Supply, delivery and fabrication of HYSD Steel of various sizes including cutting, bending, tying of grills with binding wire, fabrication charges and placing grills in position including cost and conveyance of all materials including cost of binding wire and all labour charge etc., complete as per S.S and directed by the departmental authorities |
| 809 | Providing invert filter media with following sizes of metal including cost of material, laying charges etc., complete |
| 810 | 40 mm Metal |
| 811 | 12 to 20 mm metal |
| 812 | Supply and fixing ofStainless steel Ladder made out of suitable sections for access from Infiltration well top slab to Bottom |
| 813 | Supply and fixing of ISMB 150 including cost and conveyance to work spot including two coats of anti corrossive black painting including all labour charges for cutting and placing in position etc.complete as per S.S |
| 814 | Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site, seignorage charges and labour charges for mixing of mortar, plastering and curing etc., complete as per S.S for inside of well, Inlet chamber, Screen & Grit Chambers |
| 815 | Providing impervious course with C.M (1:3)20 mm thick and mixing with acco proof compound of 1kg per one bag of cement including cost and conveyance of all materials and labour charges for finishing and curing etc., complete as per SS (APDSS NO:903) |
| 816 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities |
| 817 | Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 818 | Supply, delivery and fixing of G.I Pressed section steel Windows with frameof 100mm x 40mm hallow metal pressed section with 1.25mm thick.The shutters front and back sheet is having vertical and horizontal corrugations.They should be joined together with spot welding.The cost including all necessary fixtures such as holdfasts, aldrops & tower bolts etc., complete as per standard specification and as directed by the departmental authorities. |
| 819 | Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 820 | Supply, delivery, lowering and keeping in position ofDI D/F Gate Valve (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4.All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. The rate including cost, CST, Excise duty and conveyance to work spot and stacking care fully at site etc.complete as per S.S |
| 821 | Supply and delivery of 600mm dia. centrifugally cast (spun) Ductile Iron tail piece fitting with required flanged (welded) ends and socket end confirming to specification No.IS 8329/2000 with cement lining inside the pipe, out side Zinc coating including cost of fitting, VAT and other duties. The rate including transportation and conveyance to work spot and fixing in position etc., complete as per S.S and as directed by the departmental authorities for finished item of work. |
| 822 | Supply and delivery of C.I/M.S 12.0Mt. long operating handle with rod & wheel for operation of D.I. Sluice valve inside the intake well as per the actuals and as directed by the departmental authorities. |
| 823 | Supply and erection of MS Gantry girder with Chain pulley arrangements as per the approved designs and drawings |
| 824 | Supply and fixing of Alluminium Ladder made out of suitable sections for access from floor slab to Base slab |
| 825 | Providing MS hand railing made out of suitath MS angles and GI pipe including cost and conveyance of material and fabrication charges and painting as per SS and as directed by the engineer in charge of the work. |
| 826 | Supply, delivery, and erection of clear water Vertical turbine Pumpsetshaving a discharge of 144m3/hr against a head of 85 mts of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformet to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete .(3 Nos. of 55 KW)in the Infiltation well cum Pump House near the exisitng Head Works at Alamajipeta for pumping water to the existing 250 KL ELSR at Municipal office, 600 KL ELSR at Govt Jr College, 600 KL at Mettakavalasa & proposed 500 KL ELSR at Chintada. |
| 827 | Providing Clear Water Pumping system at Vamsadhara river by supply, delivery and erection ofVT pump set with specifications ofHead range of 85 mtrs, discharge of 144 M3/Hr for clear Water(2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.A. Supply and Delivery of Verticle Turbine (VT) Pump set: Supply, erection, testing and commissioning ofVertical Turbine pump ( VT pump set) with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing and belmouth with cast iron, impeller, shaft sleeves,muff coupling units-CF-8M ,shaftSleeves and wearings withbronze, shaft with SS410, throdenbering with Bronze with rubber lined, suitable shaft sealing system with stuffing box arrangement, provison for , fixing of suitable diapressure guages with Gliseron filling and the pump driven withLT Squirrel cage inductionDrive rated Motor (Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM suitable for pump selection solid shaft TEFC enclosure, IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Coupling, coupling guard and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractor 1 UnitB. Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing. 1 UnitC. Internal Pipe lines: Deviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance. 1 SetD. Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.C.fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header. 1 SetE. Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete 1 Seti.. Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer 1 No ii. Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare 2 Nos iii. Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station 1 Set iv. ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps 2 Sets v. Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panel 1 Set F. Supply, laying, termination and testing suitable capacity of1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) 1 Lot G. Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete. 1 Lot H. Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc; 1 Seti. Ring Spanner 3/16 to 1\" 1 No ii Double end spanner set 3/16\" to 1\" 1 No iii. Pipe Wrench 18\" & 4\" 2 Nos iv. Screw drivers 6\", 10\" & 12\" 3 Nos v. Cutting Plier 12\" 1 No vi 2 Kgs Hammer with Handle 1 No vii Nose Plier 1 No viii Flat and Half round smooth file 2 Set ix Adjustable Spanner 6\" 1 Set x Column pipe Clamps 2 Pair xi Line Shaft Clamps 1 Pair xii Line rope and clamps double the weight of pump 2 Set xiii Gland thghtening Spanner 1 No xiv Spitter removing Spanner 1 No I. Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete 1 Seti. Fire extiguisher 3Kg capacity 2 No ii Rubber Mat 6\" x 4\" 2 No iii. Fire Buckets with stand and three buckets 1 No iv. Rubber Hand Gloves 1 Set v. Danger Board Plates 4 No vi First aid kit with chart 1 No vii Shock Treatment Chart 1 No viii Portable rechargeble torch light 1 No ix Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc; 1 No J. Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc., 1 SetK. All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field Engineer 1 SetL. Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection 1 Job |
| 828 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.A. VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector control 1 SetB. Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder 1 SetsC. Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder 1 SetsD. Power transformer, required push buttons and MFM for each Main pump feeder 1 Sets |
| 829 | Supply, delivery , erection and commissioning of 250 KVA Transformer near the the exisitng Head Works at Alamajipeta. |
| 830 | Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 831 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 832 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 833 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 834 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 835 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 836 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 837 | Providing stay sets for thestructures complete with stay wire 11 KV guy insulators. Stay rod bow, thimble etx., |
| 838 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 839 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 840 | A) Earth Electrodes |
| 841 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 842 | C) Epoxy insulators |
| 843 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 844 | Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-04044c 250KVA1. Quantity : 12. Rated KVA :250 KVA3. Service & Location: Continuous Outdoor Distribution Transformer4. Mounting : Plinth.5. Wound : CopperDouble wound 6. Type :Core type oil immersed 7. Cooling : ONAN8. TempRise : 40⁰C in oil 45⁰C by resistance9. Vector Group:Dyn 1110. Primary Connection :Delta11. Nominal Voltage / Current : ______12. Highest system Voltage: 12000V13. Primary Frequency :50 HZ +/- 3%14. Number of Phases : 315. Primary wires:316. Secondary connection : Star17. SecondaryVolts / Current :433V18. Secondary phases :319. Secondary wires:420. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps)21. Terminal arrangement. a.HV: HT terminal box as per the site condition.b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable22. LV:One separate terminal for earthing.23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats25. Percentage Impedance at 75 deg C AT 4.526. No load Current Less than 2% of full load Current 27. Standrad Fittings & Accessories.a. Rating and terminal marking plate: Oneb. Lifting Lugs:Two c. Off-circuit tap switch :One d. EarthingTerminals :Two e. Radiators ( Attachable):Adequate f.Explosion vent with Diaphragm :One g. Conservator with Drain plug:oneh. Oil filling hole with cap :Onei.Oil level indicator : One j.Dehydrating Silicagel Breather : Onek. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing: One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type) |
| 845 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 846 | LT panel |
| 847 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 848 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 849 | Incoming |
| 850 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 851 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 852 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 853 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 854 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 855 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 856 | g).3RYB Phase indication lamps with leds |
| 857 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 858 | Out-Going |
| 859 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 860 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 861 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 862 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 863 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 864 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 865 | .KWH digital meter fro lighting section |
| 866 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 867 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 868 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 869 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 870 | Supply and Laying of 3C X50Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03457b |
| 871 | Transformer yard |
| 872 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means column footings |
| 873 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 874 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 875 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 876 | column footings |
| 877 | Columns, 1.20-0.10-0.10-0.30+1.80 |
| 878 | Plinth beam2(15+12)=54-gate3.00=51.00 |
| 879 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 880 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 881 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 882 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 883 | Providind Synthetic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 884 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 885 | Supply, delivery, laying , jointing and testing of 350 mm dia D.I K9 Pumping mainfrom the proposed collection well cum Pump House near the the exisitng Head Works at Alamajipeta to Junction point-A at AB Road. |
| 886 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Machinary means |
| 887 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 888 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Manual means |
| 889 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 890 | Plain Cement Concrete 1:3:6using 20mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties |
| 891 | Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties _ 350mm dia. |
| 892 | Manufacture, Supply and delivery of DI D/F Sluice valves conforming to IS 14846/2000 with amendments No. 1&2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The rates areincluding transportation, Central Excise duty and VAT etc., The operation can be done with handwheel/cap. ISI Marked. |
| 893 | 300 DN P.N.1.00 (Sectionalisation) |
| 894 | 200 DN P.N.1.00 (Scour) |
| 895 | Manufacture, Supply and delivery of CI D/F Kinetic Air Valve as per IS:14845 Heavy Duty with isolating valve bevel gear operated as per IS 14846 excluding transportation, Central Excise duty and sales tax etc., complete. |
| 896 | Manufacture, Supply and delivery of CI D/F Kinetic Air Valve as per IS:14845 Heavy Duty with isolating valve bevel gear operated as per IS 14846 excluding transportation, Central Excise duty and sales tax etc., complete. |
| 897 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spegot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) 350 mm dia |
| 898 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 350 mm dia |
| 899 | Labour charges for lowering and keeping in position of C.I. / D.I D/F sluice valves etc., complete. |
| 900 | 250 mm DN Scour Valve |
| 901 | 200 mm DN Sluice Valve |
| 902 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 100 DN Kinetic AirValve |
| 903 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 904 | Jointing DI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 905 | 350 mm dia |
| 906 | 300 mm dia |
| 907 | 200 mm dia |
| 908 | 100 mm dia |
| 909 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 910 | 300 DN Sectional valve chambers |
| 911 | 200 DN scour valve chambers |
| 912 | 100 DN Air valve chambers |
| 913 | Supply & delivery of HYSD Fe415/500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 914 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 915 | Design and Construction of 600 KL capacity ELSR near Municipal Office with a stagging of 20 mts including Inlet, Outlet, Overflow, Scour connections and dog legged stair case and all other connections etc complete. |
| 916 | 1) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs 60000/- per MT(Fe 500) (BoCE rates for the month of March-2024).2) All concrete components shall be designed with M30 Design Mix proportion.3) For intermediate capacities proportional rates shall be adopted.4) The foundations shall be designed for Annular Raft Footings. The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqm.a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on basic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate up to 20 T/Sqmc) For SBC 10T/Sqm to 7.5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate.d) For SBC 7.5 T/Sqm to 5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 15% on basic rate.e) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which additional payment shall be made as per field condition.5) For staging less than 15 m, the rate shall be decreased by Rs.0.05 paisa on basic rate per liter per every Meter decrease in staging.6) For staging above 15 m, the rate shall be increased by Rs.0.10 paisa on basic rate per liter per every Meter additional staging.7) The above rates shall be increased / decreased due to increase/decrease in the cost of cement by Basic rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.8) The above rates shall be increased / decreased due to increase/decrease in the cost of Steel by Basic rate x {(Rs-60000)/60000} x0.2 Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof.b)The rate inclusive of 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, Pipes, Pipe specials, valves of DI material, Valve chambers etc., for pipe connections including cost of pipes, specials and valves as per departmental designs and drawings.10) For tribal/Agency / Rural area, the above rates as arrived up to shall be increased by 10%.11) The above rates adopted for a wind pressure up to \"250 kg/Sqm\". For every 100 kg/Sqm decrease in wind pressure, the rate shall be decreased by 5%12)a) The Basic rate is adopted by considering the design for Seismic forces for Zone- II only of seismic zones.(b) The basic rates shall be increased by 15 % for Zone-III of seismic zones.13-(a). The ELSR/OHSR shall be designed with minimum of two rows of columns for capacities above 500 KL & up to 1000KL.13-(b). The ELSR/OHSR shall be designed with minimum of three rows of columns for capacities above 1000KL.14. The shaft type staging with slip form can also be provided with proper approval from competent authority without any additional cost.15) The basic rate is inclusive of following Fixturesi) Pipe connections & Specials with D.I materials(a) All pipe connections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DI material. (b) The Valves for above pipe connections also shall be of DI material of PN 16 duty confirming to the specification of SoR item No.28(c) All specials such as Bends, Tees, Reducers, Duck foot Bends, Bell mouths etc,. Shall be of DI material.II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs Inlet Pipe - 300mm dia. Out let Pipe - 350mm dia.DI valves – 2 No’s Over Flow pipe - 350m dia. Scour Pipe - 200mm dia.b) For 800 KL to 1500 Kl ELSRs Inlet Pipe - 400mm dia. Out let Pipe - 450mm dia.DI valves – 2 No’s Over Flow pipe - 450m dia. Scour Pipe - 200mm dia.c) For above 1500 KL to 2500 Kl ELSRsInlet Pipe - 400mm dia. Out let Pipe - 500mm dia.DI valves – 2 No’s Over Flow pipe - 500m dia. Scour Pipe - 200mm dia.Note: Any deviation from the above sizes as per design, shall be paid or recovered.(iii) Manhole Frames & Coversa) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min. of 150mm dia.) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos.v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 Noviii) The staircase shall be enclosed with brick masonry walls on three sides and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement. The Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia. pipe & middle railing of 25mm dia. and verticals with 40mm dia. at an interval not more than of 1.00m c/c.xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No)xii) Lightening Arrestor with all its accessories complete including earthing, with relevant IS Codes - 1 No.xiii) Compound wall: Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall is minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM (1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8) prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Ground level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angular of 25mm X 25mm X 4mm in \"Y\" shape to height of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauges shall be stretched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4)prop on both sides of brick work.Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreasedNote:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL shall be as follows.: i)500 KL : 0.086% ii)1000 KL : 0.047% iii)1500 KL : 0.034% iv)2000 KL : 0.026% v)2500 KL : 0.022 % For intermediate capacities, interpolated percentages shall be adopted.xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 Sqm with the following specification: RCC framed structure with concrete grade not less than M20 design mix at the locations specified by the department at the time of execution with veranda, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases.MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides open able shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall be provided. Septic tank for 5 users shall be provided. |
| 917 | Design and Construction of 600 KL capacity ELSR at Mettakavalasawith a stagging of 25 mts including Inlet, Outlet, Overflow, Scour connections and dog legged stair case and all other connections etc complete. |
| 918 | 1) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs 60000/- per MT(Fe 500) (BoCE rates for the month of March-2024).2) All concrete components shall be designed with M30 Design Mix proportion.3) For intermediate capacities proportional rates shall be adopted.4) The foundations shall be designed for Annular Raft Footings. The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqm.a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on basic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate up to 20 T/Sqmc) For SBC 10T/Sqm to 7.5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate.d) For SBC 7.5 T/Sqm to 5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 15% on basic rate.e) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which additional payment shall be made as per field condition.5) For staging less than 15 m, the rate shall be decreased by Rs.0.05 paisa on basic rate per liter per every Meter decrease in staging.6) For staging above 15 m, the rate shall be increased by Rs.0.10 paisa on basic rate per liter per every Meter additional staging.7) The above rates shall be increased / decreased due to increase/decrease in the cost of cement by Basic rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.8) The above rates shall be increased / decreased due to increase/decrease in the cost of Steel by Basic rate x {(Rs-60000)/60000} x0.2 Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof.b)The rate inclusive of 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, Pipes, Pipe specials, valves of DI material, Valve chambers etc., for pipe connections including cost of pipes, specials and valves as per departmental designs and drawings.10) For tribal/Agency / Rural area, the above rates as arrived up to shall be increased by 10%.11) The above rates adopted for a wind pressure up to \"250 kg/Sqm\". For every 100 kg/Sqm decrease in wind pressure, the rate shall be decreased by 5%12)a) The Basic rate is adopted by considering the design for Seismic forces for Zone- II only of seismic zones.(b) The basic rates shall be increased by 15 % for Zone-III of seismic zones.13-(a). The ELSR/OHSR shall be designed with minimum of two rows of columns for capacities above 500 KL & up to 1000KL.13-(b). The ELSR/OHSR shall be designed with minimum of three rows of columns for capacities above 1000KL.14. The shaft type staging with slip form can also be provided with proper approval from competent authority without any additional cost.15) The basic rate is inclusive of following Fixturesi) Pipe connections & Specials with D.I materials(a) All pipe connections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DI material. (b) The Valves for above pipe connections also shall be of DI material of PN 16 duty confirming to the specification of SoR item No.28(c) All specials such as Bends, Tees, Reducers, Duck foot Bends, Bell mouths etc,. Shall be of DI material.II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs Inlet Pipe - 300mm dia. Out let Pipe - 350mm dia.DI valves – 2 No’s Over Flow pipe - 350m dia. Scour Pipe - 200mm dia.b) For 800 KL to 1500 Kl ELSRs Inlet Pipe - 400mm dia. Out let Pipe - 450mm dia.DI valves – 2 No’s Over Flow pipe - 450m dia. Scour Pipe - 200mm dia.c) For above 1500 KL to 2500 Kl ELSRsInlet Pipe - 400mm dia. Out let Pipe - 500mm dia.DI valves – 2 No’s Over Flow pipe - 500m dia. Scour Pipe - 200mm dia.Note: Any deviation from the above sizes as per design, shall be paid or recovered.(iii) Manhole Frames & Coversa) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min. of 150mm dia.) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos.v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 Noviii) The staircase shall be enclosed with brick masonry walls on three sides and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement. The Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia. pipe & middle railing of 25mm dia. and verticals with 40mm dia. at an interval not more than of 1.00m c/c.xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No)xii) Lightening Arrestor with all its accessories complete including earthing, with relevant IS Codes - 1 No.xiii) Compound wall: Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall is minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM (1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8) prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Ground level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angular of 25mm X 25mm X 4mm in \"Y\" shape to height of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauges shall be stretched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4)prop on both sides of brick work.Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreasedNote:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL shall be as follows.: i)500 KL : 0.086% ii)1000 KL : 0.047% iii)1500 KL : 0.034% iv)2000 KL : 0.026% v)2500 KL : 0.022 % For intermediate capacities, interpolated percentages shall be adopted.xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 Sqm with the following specification: RCC framed structure with concrete grade not less than M20 design mix at the locations specified by the department at the time of execution with veranda, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases.MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides open able shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall be provided. Septic tank for 5 users shall be provided. |
| 919 | Construction of 600 mm dia Infiltration gallery from proposed Infiltration well cum pump house in the Nagavali River near the exisitng Head Water works at Kothavalasa. |
| 920 | Excavation of trenches for infiltration galleries and connecting mains in all soils under water including all leads, lifts, shoring, strutting, bailing out water and removal of shoring and strutting materials after completion of pipe line work. |
| 921 | 0.00 to 1.00 m depth |
| 922 | b) 1.00 to 2.00m deep |
| 923 | c) 2.00 to 5.00mdeep |
| 924 | d) 5.00 to 6.00 m deep |
| 925 | e) 6.00 to 7.00 m deep |
| 926 | Manufacture, supply and delivery of 600mm dia. S/S RCC NP3 class perforated pipes for Infiltration gallery including cost and conveyance to work spot and handling charges providing perforated holes including all taxes and duties etc., complete as per S.S |
| 927 | Lowering, laying and jointing of 600mm dia. RCC perforated pipes of NP3 class inclusive of bailing out water and jointing with cement fillets, and all other incidental charges for infiltration gallery inclusive of bailing out water by pumping to keep the trench reasonably dry to fecilate the work excluding cost of perforated pipes and collars. |
| 928 | Providing and construction of transition cum filter media using approved or recommended material i.e., 230mm thick 230mm thick 40-20mm C.A, 230mm thick 20-12mm C.A, 230mm thick 12-6mm C.A, 230mm thick Coarse sand and 400mm thick fine sand satisfying the filter criteria including machinery, labour, laying each layer to required slope, compaction etc., complete with all extra leads and de lifts |
| 929 | 40 mm to 20mm size Coarse aggregate |
| 930 | 20 mm to 12 mm size Coarse aggregate |
| 931 | 12 mm to 6 mm size Coarse aggregate |
| 932 | Coarse sand |
| 933 | Fine sand |
| 934 | Construction of 4.00 mts dia RCC Infiltration well cum Pump House in Nagavali River near the existing Head Water works at Kothavalasa. |
| 935 | Supply, delivery, fabrication and erection of cutting toe for well curb with ISA 100x100x10mm including cost and conveyance to work spot including all labour charges for fabrication and erection etc.,complete as directed by the departmental authorities. |
| 936 | Earthwork in excavation as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH |
| 937 | Well sinking in sandy and other loose soils under water either by manual labour, divers, or dredgers, weighing the top of steining to assist sinking etc., including dewatering and other incidental charges such as hire charges for mechanical equipment etc,complete for an internal dia of 4.00mts |
| 938 | a) Up to 2.00mts depth |
| 939 | b) 2.00mts to 4.00mts depth |
| 940 | c) 4.00mts to 6.00mts depth |
| 941 | d) 6.00mts to 8.00mts depth |
| 942 | e) 8.00mts to 8.70 mts depth |
| 943 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete with all de-lift charges but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) |
| 944 | Well Curb |
| 945 | Side walls (Well Steining) - Well 1 |
| 946 | Side walls (Well Steining) - Well 1 |
| 947 | Well top cover slab 200 mm thick. |
| 948 | Supply, delivery and fabrication of HYSD Steel of various sizes including cutting, bending, tying of grills with binding wire, fabrication charges and placing grills in position including cost and conveyance of all materials including cost of binding wire and all labour charge etc., complete as per S.S and directed by the departmental authorities |
| 949 | Providing invert filter media with following sizes of metal including cost of material, laying charges etc., complete |
| 950 | 40 mm Metal |
| 951 | 12 to 20 mm metal |
| 952 | Supply and fixing ofStainless steel Ladder made out of suitable sections for access from Infiltration well top slab to Bottom |
| 953 | Supply and fixing of ISMB 150 including cost and conveyance to work spot including two coats of anti corrossive black painting including all labour charges for cutting and placing in position etc.complete as per S.S |
| 954 | Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site, seignorage charges and labour charges for mixing of mortar, plastering and curing etc., complete as per S.S for inside of well, Inlet chamber, Screen & Grit Chambers |
| 955 | Providing impervious course with C.M (1:3)20 mm thick and mixing with acco proof compound of 1kg per one bag of cement including cost and conveyance of all materials and labour charges for finishing and curing etc., complete as per SS (APDSS NO:903) |
| 956 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities |
| 957 | Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 958 | Supply, delivery and fixing of G.I Pressed section steel Windows with frame of 100mm x 40mm hallow metal pressed section with 1.25mm thick.The shutters front and back sheet is having vertical and horizontal corrugations.They should be joined together with spot welding.The cost including all necessary fixtures such as holdfasts, aldrops & tower bolts etc., complete as per standard specification and as directed by the departmental authorities. |
| 959 | Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 960 | Supply, delivery, lowering and keeping in position ofDI D/F Gate Valve (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4.All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. The rate including cost, CST, Excise duty and conveyance to work spot and stacking care fully at site etc.complete as per S.S |
| 961 | Supply and delivery of 600mm dia. centrifugally cast (spun) Ductile Iron tail piece fitting with required flanged (welded) ends and socket end confirming to specification No.IS 8329/2000 with cement lining inside the pipe, out side Zinc coating including cost of fitting, VAT and other duties. The rate including transportation and conveyance to work spot and fixing in position etc., complete as per S.S and as directed by the departmental authorities for finished item of work. |
| 962 | Supply and delivery of C.I/M.S 12.0Mt. long operating handle with rod & wheel for operation of D.I. Sluice valve inside the intake well as per the actuals and as directed by the departmental authorities. |
| 963 | Supply and erection of MS Gantry girder with Chain pulley arrangements as per the approved designs and drawings |
| 964 | Supply and fixing of Alluminium Ladder made out of suitable sections for access from floor slab to Base slab |
| 965 | Providing MS hand railing made out of suitath MS angles and GI pipe including cost and conveyance of material and fabrication charges and painting as per SS and as directed by the engineer in charge of the work. |
| 966 | Supply, delivery, and erection of clear water SubmersiblePumpsetshaving a discharge of 72m3/hr against a head of 73 mts of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformet to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete (2 Nos. of 22.50 KW) in the Infiltation well cum Pump House near the exisitng Head Works at Kothavalasa for pumping water to the existing 500 KL ELSR at Venkayyapeta. |
| 967 | Providing Clear Water Pumping system at Nagavali riverby supply, delivery and erection ofSS pump set with specifications ofHead range of 73mtrs, discharge of 72M3/Hr for clear Water(2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.A. Supply and Delivery of Verticle Turbine (SS) Pump set: Supply, erection, testing and commissioning ofVertical Turbine pump ( VT pump set) with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing and belmouth with cast iron, impeller, shaft sleeves,muff coupling units-CF-8M ,shaftSleeves and wearings withbronze, shaft with SS410, throdenbering with Bronze with rubber lined, suitable shaft sealing system with stuffing box arrangement, provison for , fixing of suitable diapressure guages with Gliseron filling and the pump driven withLT Squirrel cage inductionDrive rated Motor (Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM suitable for pump selection solid shaft TEFC enclosure, IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Coupling, coupling guard and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractor 1 UnitB. Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing. 1 UnitC. Internal Pipe lines: Deviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance. 1 SetD. Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.C.fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header. 1 SetE. Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete 1 Seti.. Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer 1 No ii. Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare 2 Nos iii. Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station 1 Set iv. ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps 2 Sets v. Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panel 1 Set F. Supply, laying, termination and testing suitable capacity of1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) 1 Lot G. Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete. 1 Lot H. Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc; 1 Seti. Ring Spanner 3/16 to 1\" 1 No ii Double end spanner set 3/16\" to 1\" 1 No iii. Pipe Wrench 18\" & 4\" 2 Nos iv. Screw drivers 6\", 10\" & 12\" 3 Nos v. Cutting Plier 12\" 1 No vi 2 Kgs Hammer with Handle 1 No vii Nose Plier 1 No viii Flat and Half round smooth file 2 Set ix Adjustable Spanner 6\" 1 Set x Column pipe Clamps 2 Pair xi Line Shaft Clamps 1 Pair xii Line rope and clamps double the weight of pump 2 Set xiii Gland thghtening Spanner 1 No xiv Spitter removing Spanner 1 No I. Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete 1 Seti. Fire extiguisher 3Kg capacity 2 No ii Rubber Mat 6\" x 4\" 2 No iii. Fire Buckets with stand and three buckets 1 No iv. Rubber Hand Gloves 1 Set v. Danger Board Plates 4 No vi First aid kit with chart 1 No vii Shock Treatment Chart 1 No viii Portable rechargeble torch light 1 No ix Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc; 1 No J. Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc., 1 SetK. All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field Engineer 1 SetL. Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection 1 Job |
| 968 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.A. VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector control 1 SetB. Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder 1 SetsC. Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder 1 SetsD. Power transformer, required push buttons and MFM for each Main pump feeder 1 Sets |
| 969 | Supply,delivery, laying , jointing, testing and commissioning of 200 mm dia D.I K9 pumping main from the proposed Infiltration well cum pump house to the exisitng 150 mm D.I pumping main at Kothavalasa. |
| 970 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Machinary means |
| 971 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Manual means |
| 972 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 973 | Plain Cement Concrete 1:3:6using 20mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties |
| 974 | Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties |
| 975 | Manufacture, Supply and delivery of DI D/F Sluice valves conforming to IS 14846/2000 with amendments No. 1&2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The rates areincluding transportation, Central Excise duty and VAT etc., The operation can be done with handwheel/cap. ISI Marked. |
| 976 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 977 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spegot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 978 | (PHE-LCIF-2) Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged ends carefully into trench and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply. |
| 979 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 980 | Labour charges for lowering and keeping in position of C.I. / D.I D/F sluice valves etc., complete. |
| 981 | Jointing DI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 982 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 983 | Supply & delivery of HYSD Fe415/500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 984 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 985 | Supply, delivery, and erection of Clear water Horizontal split casing CentrifugalPumpsetshaving a discharge of 72m3/hr against a head of 61 mts of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformer to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete(2 Nos. of 22.50 KW) in the existing Pump House at Municipal officefor pumping water to the proposed 200 KL ELSR at Timapuram . |
| 986 | Providing Clear Water Pumping system at Pump House near Municipal Office by supply, delivery and erection ofHSC pump set with specifications ofHead range of61 mtrs, discharge of 72 M3/Hr for clear Water(2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.A. Supply and Delivery of Verticle Turbine (HSC) Pump set: Supply, erection, testing and commissioning ofVertical Turbine pump ( VT pump set) with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing and belmouth with cast iron, impeller, shaft sleeves,muff coupling units-CF-8M ,shaftSleeves and wearings withbronze, shaft with SS410, throdenbering with Bronze with rubber lined, suitable shaft sealing system with stuffing box arrangement, provison for , fixing of suitable diapressure guages with Gliseron filling and the pump driven withLT Squirrel cage inductionDrive rated Motor (Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM suitable for pump selection solid shaft TEFC enclosure, IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Coupling, coupling guard and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractor 1 UnitB. Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing. 1 UnitC. Internal Pipe lines: Deviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance. 1 SetD. Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.C.fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header. 1 SetE. Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete 1 Seti.. Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer 1 No ii. Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare 2 Nos iii. Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station 1 Set iv. ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps 2 Sets v. Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panel 1 Set F. Supply, laying, termination and testing suitable capacity of1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) 1 Lot G. Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete. 1 Lot H. Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc; 1 Seti. Ring Spanner 3/16 to 1\" 1 No ii Double end spanner set 3/16\" to 1\" 1 No iii. Pipe Wrench 18\" & 4\" 2 Nos iv. Screw drivers 6\", 10\" & 12\" 3 Nos v. Cutting Plier 12\" 1 No vi 2 Kgs Hammer with Handle 1 No vii Nose Plier 1 No viii Flat and Half round smooth file 2 Set ix Adjustable Spanner 6\" 1 Set x Column pipe Clamps 2 Pair xi Line Shaft Clamps 1 Pair xii Line rope and clamps double the weight of pump 2 Set xiii Gland thghtening Spanner 1 No xiv Spitter removing Spanner 1 No I. Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete 1 Seti. Fire extiguisher 3Kg capacity 2 No ii Rubber Mat 6\" x 4\" 2 No iii. Fire Buckets with stand and three buckets 1 No iv. Rubber Hand Gloves 1 Set v. Danger Board Plates 4 No vi First aid kit with chart 1 No vii Shock Treatment Chart 1 No viii Portable rechargeble torch light 1 No ix Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc; 1 No J. Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc., 1 SetK. All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field Engineer 1 SetL. Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection 1 Job |
| 987 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.A. VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector control 1 SetB. Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder 1 SetsC. Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder 1 SetsD. Power transformer, required push buttons and MFM for each Main pump feeder 1 Sets |
| 988 | Supply, delivery, laying, jointing and testing of 200 mm dia D.I K9 pumping mainfrom Junction-Bto proposed 600 KL ELSR at Mettakavalasa. |
| 989 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by machinary means |
| 990 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by manual means |
| 991 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 992 | Plain Cement Concrete 1:3:6using 20mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties for Thrust Blocks 90° bend |
| 993 | Manufacture, Supply and delivery of DI D/F Sluice valves conforming to IS 14846/2000 with amendments No. 1&2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The rates areincluding transportation, Central Excise duty and VAT etc., The operation can be done with handwheel/cap. ISI Marked. |
| 994 | 200 DN P.N.1.00 (Sectionalisation) |
| 995 | 150 DN P.N.1.00 (Sectionalisation) |
| 996 | Manufacture, Supply and delivery of CI D/F Kinetic Air Valve as per IS:14845 Heavy Duty with isolating valve bevel gear operated as per IS 14846 excluding transportation, Central Excise duty and sales tax etc., complete. 80 DN P.N.1.00 |
| 997 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 998 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spegot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) 200 mm dia |
| 999 | (PHE-LCIF-2) Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged ends carefully into trench and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply.200 mm dia |
| 1000 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 200 mm dia |
| 1001 | Labour charges for lowering and keeping in position of C.I. / D.I D/F sluice valves etc., complete. |
| 1002 | 200 DN SluiceValve |
| 1003 | 150 DN Scour Valve |
| 1004 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 DN Kinetic AirValve |
| 1005 | Jointing DI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) 200 mm dia |
| 1006 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 1007 | 200 DN Sectional valve chambers |
| 1008 | 150 DN scour valve chambers |
| 1009 | 80 DN Air valve chambers |
| 1010 | Supply & delivery of HYSD Fe415/500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 1011 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1012 | Supply, delivery, laying , jointing and testing of 250 mm dia D.I K9 pumping mainfrom Junction-Bto the proposed 500 KL ELSR at Chintada. |
| 1013 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Machinary means |
| 1014 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Manual means |
| 1015 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 1016 | Plain Cement Concrete 1:3:6using 20mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties for Thrust Blocks |
| 1017 | Manufacture, Supply and delivery of DI D/F Sluice valves conforming to IS 14846/2000 with amendments No. 1&2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The rates areincluding transportation, Central Excise duty and VAT etc., The operation can be done with handwheel/cap. ISI Marked. |
| 1018 | 250 DN P.N.1.00 (Sectionalisation) |
| 1019 | 150 DN P.N.1.00 (Scour) |
| 1020 | Manufacture, Supply and delivery of CI D/F Kinetic Air Valve as per IS:14845 Heavy Duty with isolating valve bevel gear operated as per IS 14846 excluding transportation, Central Excise duty and sales tax etc., complete. |
| 1021 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1022 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spegot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) 250mm dia |
| 1023 | (PHE-LCIF-2) Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged ends carefully into trench and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply.250mm dia |
| 1024 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 250mm dia |
| 1025 | Labour charges for lowering and keeping in position of C.I. / D.I D/F sluice valves etc., complete. |
| 1026 | 250 DN Sluice Valve |
| 1027 | 150 DN Scour Valve |
| 1028 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 DN Kinetic AirValve |
| 1029 | Jointing DI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1030 | 250 mm dia |
| 1031 | 150 mm dia |
| 1032 | 80 mm dia |
| 1033 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 1034 | 300 DN Sectional valve chambers |
| 1035 | 250 DN scour valve chambers |
| 1036 | 80 DN Air valve chambers |
| 1037 | Supply & delivery of HYSD Fe415/500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 1038 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1039 | Supply, delivery, laying , jointing and testing of 250 mm dia D.I K9 pumping mainfrom Junction-Ato Junction-C near Govt Jr College |
| 1040 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Machinary means |
| 1041 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Manual means |
| 1042 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 1043 | Plain Cement Concrete 1:3:6using 20mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties |
| 1044 | Manufacture, Supply and delivery of DI D/F Sluice valves conforming to IS 14846/2000 with amendments No. 1&2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The rates areincluding transportation, Central Excise duty and VAT etc., The operation can be done with handwheel/cap. ISI Marked. |
| 1045 | 250 DN P.N.1.00 (Sectionalisation) |
| 1046 | 150 DN P.N.1.00 (Scour) |
| 1047 | Manufacture, Supply and delivery of CI D/F Kinetic Air Valve as per IS:14845 Heavy Duty with isolating valve bevel gear operated as per IS 14846 excluding transportation, Central Excise duty and sales tax etc., complete. 80 DN P.N.1.00 |
| 1048 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1049 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spegot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 1050 | (PHE-LCIF-2) Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged ends carefully into trench and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply. |
| 1051 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 1052 | Labour charges for lowering and keeping in position of C.I. / D.I D/F sluice valves etc., complete. |
| 1053 | 250 DN Sluice Valve |
| 1054 | 150 DN Scour Valve |
| 1055 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 DN Kinetic AirValve |
| 1056 | Jointing DI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1057 | 250 mm dia |
| 1058 | 150 mm dia |
| 1059 | 80 DN P.N.1.00 |
| 1060 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 1061 | 300 DN Sectional valve chambers |
| 1062 | 250 DN scour valve chambers |
| 1063 | 80 DN Air valve chambers |
| 1064 | Supply & delivery of HYSD Fe415/500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 1065 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1066 | Supply, delivery, laying , jointing and testing of 200 mm dia D.I K9 puming main from Junction-C to proposed 600 KL ELSR near Municipal Office |
| 1067 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Machinary means |
| 1068 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Manual means |
| 1069 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 1070 | Plain Cement Concrete 1:3:6using 20mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties |
| 1071 | Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties200DN |
| 1072 | Manufacture, Supply and delivery of DI D/F Sluice valves conforming to IS 14846/2000 with amendments No. 1&2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The rates areincluding transportation, Central Excise duty and VAT etc., The operation can be done with handwheel/cap. ISI Marked.200 DN P.N.1.00 (Sectionalisation) |
| 1073 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1074 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spegot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 1075 | (PHE-LCIF-2) Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged ends carefully into trench and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply. |
| 1076 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 1077 | Labour charges for lowering and keeping in position of C.I. / D.I D/F sluice valves etc., complete. |
| 1078 | Jointing DI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1079 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 200 DN Sectional valve chambers |
| 1080 | Supply & delivery of HYSD Fe415/500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 1081 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1082 | Supply, delivery, laying , jointing and testing of 150 mm dia D.I K9 puming main from Junction-C to exisitng 250 KL ELSR at Municipal office & proposed ELSR |
| 1083 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Machinary means |
| 1084 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m by Manual means |
| 1085 | Earthworkexcavationin ordinary soils including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width upto a depth of 3.00m in Hard Rock |
| 1086 | Plain Cement Concrete 1:3:6using 20mm graded metal including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standardspecifications for finsished item of work but excluding cost of reinforcement , fabrication charges , taxes and duties |
| 1087 | Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties 150DN |
| 1088 | Manufacture, Supply and delivery of DI D/F Sluice valves conforming to IS 14846/2000 with amendments No. 1&2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The rates areincluding transportation, Central Excise duty and VAT etc., The operation can be done with handwheel/cap. ISI Marked. |
| 1089 | 150 DN P.N.1.00 (Sectionalisation) |
| 1090 | 100 DN P.N.1.00 (Scour) |
| 1091 | Manufacture, Supply and delivery of CI D/F Kinetic Air Valve as per IS:14845 Heavy Duty with isolating valve bevel gear operated as per IS 14846 excluding transportation, Central Excise duty and sales tax etc., complete.80 DN P.N.1.00 |
| 1092 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1093 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spegot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 1094 | (PHE-LCIF-2) Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged ends carefully into trench and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply. |
| 1095 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 |
| 1096 | Labour charges for lowering and keeping in position of C.I. / D.I D/F sluice valves etc., complete. |
| 1097 | 150 DN Sluice Valve |
| 1098 | 100 DN Scour Valve |
| 1099 | Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 DN Kinetic AirValve |
| 1100 | Jointing DI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1101 | 150 mm dia |
| 1102 | 100 mm dia |
| 1103 | 80 mm dia |
| 1104 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 1105 | 150 DN Sectional valve chambers |
| 1106 | 100 DN scour valve chambers |
| 1107 | 80 DN Air valve chambers |
| 1108 | Supply & delivery of HYSD Fe415/500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 1109 | Collection and spreading ofstone crusher dust below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1110 | Supply, delivery , erection and commissioning of 100 KVA Transformer@ Municipal office |
| 1111 | Supply and erection of 7.5m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 1112 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 1113 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 1114 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 1115 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 1116 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 1117 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 1118 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 1119 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 1120 | A) Earth Electrodes |
| 1121 | B) 25 x 3 mm HDB copper flat |
| 1122 | C) Epoxy insulators |
| 1123 | D) No.\"8\" SWG Copper wire. |
| 1124 | Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.Makes : As per list of recommended brands as category I. MAT-04042 a100KVA 1. Quantity : 12. Rated KVA :100 KVA3. Service & Location: Continuous Outdoor Distribution Transformer4. Mounting : Plinth.5. Wound : CopperDouble wound 6. Type :Core type oil immersed 7. Cooling : ONAN8. TempRise : 40⁰C in oil 45⁰C by resistance9. Vector Group:Dyn 1110. Primary Connection :Delta11. Nominal Voltage / Current : ______12. Highest system Voltage: 12000V13. Primary Frequency :50 HZ +/- 3%14. Number of Phases : 315. Primary wires:316. Secondary connection : Star17. SecondaryVolts / Current :433V18. Secondary phases :319. Secondary wires:420. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps)21. Terminal arrangement. a.HV: HT terminal box as per the site condition.b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable22. LV:One separate terminal for earthing.23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats25. Percentage Impedance at 75 deg C AT 4.526. No load Current Less than 2% of full load Current 27. Standrad Fittings & Accessories.a. Rating and terminal marking plate: Oneb. Lifting Lugs:Two c. Off-circuit tap switch :One d. EarthingTerminals :Two e. Radiators ( Attachable):Adequate f.Explosion vent with Diaphragm :One g. Conservator with Drain plug:oneh. Oil filling hole with cap :Onei.Oil level indicator : One j.Dehydrating Silicagel Breather : Onek. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing: One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type) |
| 1125 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 1126 | LT PanelSupply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 1127 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 1128 | INCOMING |
| 1129 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1130 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 1131 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 1132 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 1133 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 1134 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 1135 | g).3RYB Phase indication lamps with leds |
| 1136 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 1137 | OUT-GOING |
| 1138 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1139 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1140 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1141 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1142 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1143 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 1144 | .KWH digital meter fro lighting section |
| 1145 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 1146 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 1147 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 1148 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 1149 | Supply and Laying of 3C X 35Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03456 |
| 1150 | Transformer yard |
| 1151 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual meanscolumn footings |
| 1152 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 1153 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 1154 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 1155 | column footings |
| 1156 | Columns1.20-0.10-0.10-0.30+1.80 |
| 1157 | Plinth beam2(15+12)=54-gate3.00=51.00 |
| 1158 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 1159 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 1160 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 1161 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 1162 | Providind Synthetic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 1163 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 1164 | Supply, delivery , erection and commissioning of 160 KVA Transformerfor villages @ Nagavalli source |
| 1165 | Supply and erection of 7.5m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 1166 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 1167 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 1168 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 1169 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 1170 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 1171 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 1172 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 1173 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 1174 | A) Earth Electrodes |
| 1175 | B) 25 x 3 mm HDB copper flat |
| 1176 | C) Epoxy insulators |
| 1177 | D) No.\"8\" SWG Copper wire. |
| 1178 | Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.Makes : As per list of recommended brands as category I. MAT-04042 a100KVA 1. Quantity : 12. Rated KVA :100 KVA3. Service & Location: Continuous Outdoor Distribution Transformer4. Mounting : Plinth.5. Wound : CopperDouble wound 6. Type :Core type oil immersed 7. Cooling : ONAN8. TempRise : 40⁰C in oil 45⁰C by resistance9. Vector Group:Dyn 1110. Primary Connection :Delta11. Nominal Voltage / Current : ______12. Highest system Voltage: 12000V13. Primary Frequency :50 HZ +/- 3%14. Number of Phases : 315. Primary wires:316. Secondary connection : Star17. SecondaryVolts / Current :433V18. Secondary phases :319. Secondary wires:420. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps)21. Terminal arrangement. a.HV: HT terminal box as per the site condition.b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable22. LV:One separate terminal for earthing.23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats25. Percentage Impedance at 75 deg C AT 4.526. No load Current Less than 2% of full load Current 27. Standrad Fittings & Accessories.a. Rating and terminal marking plate: Oneb. Lifting Lugs:Two c. Off-circuit tap switch :One d. EarthingTerminals :Two e. Radiators ( Attachable):Adequate f.Explosion vent with Diaphragm :One g. Conservator with Drain plug:oneh. Oil filling hole with cap :Onei.Oil level indicator : One j.Dehydrating Silicagel Breather : Onek. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing: One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type) |
| 1179 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 1180 | LT PanelSupply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 1181 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 1182 | INCOMING |
| 1183 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1184 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 1185 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 1186 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 1187 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 1188 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 1189 | g).3RYB Phase indication lamps with leds |
| 1190 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 1191 | OUT-GOING |
| 1192 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1193 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1194 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1195 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1196 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1197 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 1198 | .KWH digital meter fro lighting section |
| 1199 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 1200 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 1201 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 1202 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 1203 | Supply and Laying of 3C X 35Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03456 |
| 1204 | Transformer yard |
| 1205 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual meanscolumn footings |
| 1206 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 1207 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 1208 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 1209 | column footings |
| 1210 | Columns1.20-0.10-0.10-0.30+1.80 |
| 1211 | Plinth beam2(15+12)=54-gate3.00=51.00 |
| 1212 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 1213 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 1214 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 1215 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 1216 | Providind Synthetic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 1217 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 1218 | Construction of 500 KL capacity ELSR at Chintada with a stagging of 15 mts including Inlet , Outlet , Overflow, scour connections and dog legged stair case and all other connections etc complete. |
| 1219 | 1) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs 60000/- per MT(Fe 500) (BoCE rates for the month of March-2024).2) All concrete components shall be designed with M30 Design Mix proportion.3) For intermediate capacities proportional rates shall be adopted.4) The foundations shall be designed for Annular Raft Footings. The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqm.a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on basic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate up to 20 T/Sqmc) For SBC 10T/Sqm to 7.5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate.d) For SBC 7.5 T/Sqm to 5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 15% on basic rate.e) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which additional payment shall be made as per field condition.5) For staging less than 15 m, the rate shall be decreased by Rs.0.05 paisa on basic rate per liter per every Meter decrease in staging.6) For staging above 15 m, the rate shall be increased by Rs.0.10 paisa on basic rate per liter per every Meter additional staging.7) The above rates shall be increased / decreased due to increase/decrease in the cost of cement by Basic rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.8) The above rates shall be increased / decreased due to increase/decrease in the cost of Steel by Basic rate x {(Rs-60000)/60000} x0.2 Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof.b)The rate inclusive of 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, Pipes, Pipe specials, valves of DI material, Valve chambers etc., for pipe connections including cost of pipes, specials and valves as per departmental designs and drawings.10) For tribal/Agency / Rural area, the above rates as arrived up to shall be increased by 10%.11) The above rates adopted for a wind pressure up to \"250 kg/Sqm\". For every 100 kg/Sqm decrease in wind pressure, the rate shall be decreased by 5%12)a) The Basic rate is adopted by considering the design for Seismic forces for Zone- II only of seismic zones.(b) The basic rates shall be increased by 15 % for Zone-III of seismic zones.13-(a). The ELSR/OHSR shall be designed with minimum of two rows of columns for capacities above 500 KL & up to 1000KL.13-(b). The ELSR/OHSR shall be designed with minimum of three rows of columns for capacities above 1000KL.14. The shaft type staging with slip form can also be provided with proper approval from competent authority without any additional cost.15) The basic rate is inclusive of following Fixturesi) Pipe connections & Specials with D.I materials(a) All pipe connections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DI material. (b) The Valves for above pipe connections also shall be of DI material of PN 16 duty confirming to the specification of SoR item No.28(c) All specials such as Bends, Tees, Reducers, Duck foot Bends, Bell mouths etc,. Shall be of DI material.II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs Inlet Pipe - 300mm dia. Out let Pipe - 350mm dia.DI valves – 2 No’s Over Flow pipe - 350m dia. Scour Pipe - 200mm dia.b) For 800 KL to 1500 Kl ELSRs Inlet Pipe - 400mm dia. Out let Pipe - 450mm dia.DI valves – 2 No’s Over Flow pipe - 450m dia. Scour Pipe - 200mm dia.c) For above 1500 KL to 2500 Kl ELSRsInlet Pipe - 400mm dia. Out let Pipe - 500mm dia.DI valves – 2 No’s Over Flow pipe - 500m dia. Scour Pipe - 200mm dia.Note: Any deviation from the above sizes as per design, shall be paid or recovered.(iii) Manhole Frames & Coversa) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min. of 150mm dia.) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos.v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 Noviii) The staircase shall be enclosed with brick masonry walls on three sides and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement. The Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia. pipe & middle railing of 25mm dia. and verticals with 40mm dia. at an interval not more than of 1.00m c/c.xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No)xii) Lightening Arrestor with all its accessories complete including earthing, with relevant IS Codes - 1 No.xiii) Compound wall: Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall is minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM (1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8) prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Ground level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angular of 25mm X 25mm X 4mm in \"Y\" shape to height of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauges shall be stretched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4)prop on both sides of brick work.Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreasedNote:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL shall be as follows.: i)500 KL : 0.086% ii)1000 KL : 0.047% iii)1500 KL : 0.034% iv)2000 KL : 0.026% v)2500 KL : 0.022 % For intermediate capacities, interpolated percentages shall be adopted.xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 Sqm with the following specification: RCC framed structure with concrete grade not less than M20 design mix at the locations specified by the department at the time of execution with veranda, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases.MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides open able shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall be provided. Septic tank for 5 users shall be provided. |
| 1220 | Construction of 200 KL capacity Rectangular ELSR at Timmapuram with a stagging of 15 mts including Inlet , Outlet , Overflow, scour connections and dog legged stair case and all other connections etc complete. |
| 1221 | 1) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs 60000/- per MT(Fe 500) (BoCE rates for the month of March-2024).2) All concrete components shall be designed with M30 Design Mix proportion.3) For intermediate capacities proportional rates shall be adopted.4) The foundations shall be designed for Annular Raft Footings. The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqm.a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on basic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate up to 20 T/Sqmc) For SBC 10T/Sqm to 7.5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate.d) For SBC 7.5 T/Sqm to 5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 15% on basic rate.e) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which additional payment shall be made as per field condition.5) For staging less than 15 m, the rate shall be decreased by Rs.0.05 paisa on basic rate per liter per every Meter decrease in staging.6) For staging above 15 m, the rate shall be increased by Rs.0.10 paisa on basic rate per liter per every Meter additional staging.7) The above rates shall be increased / decreased due to increase/decrease in the cost of cement by Basic rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.8) The above rates shall be increased / decreased due to increase/decrease in the cost of Steel by Basic rate x {(Rs-60000)/60000} x0.2 Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof.b)The rate inclusive of 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, Pipes, Pipe specials, valves of DI material, Valve chambers etc., for pipe connections including cost of pipes, specials and valves as per departmental designs and drawings.10) For tribal/Agency / Rural area, the above rates as arrived up to shall be increased by 10%.11) The above rates adopted for a wind pressure up to \"250 kg/Sqm\". For every 100 kg/Sqm decrease in wind pressure, the rate shall be decreased by 5%12)a) The Basic rate is adopted by considering the design for Seismic forces for Zone- II only of seismic zones.(b) The basic rates shall be increased by 15 % for Zone-III of seismic zones.13-(a). The ELSR/OHSR shall be designed with minimum of two rows of columns for capacities above 500 KL & up to 1000KL.13-(b). The ELSR/OHSR shall be designed with minimum of three rows of columns for capacities above 1000KL.14. The shaft type staging with slip form can also be provided with proper approval from competent authority without any additional cost.15) The basic rate is inclusive of following Fixturesi) Pipe connections & Specials with D.I materials(a) All pipe connections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DI material. (b) The Valves for above pipe connections also shall be of DI material of PN 16 duty confirming to the specification of SoR item No.28(c) All specials such as Bends, Tees, Reducers, Duck foot Bends, Bell mouths etc,. Shall be of DI material.II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs Inlet Pipe - 300mm dia. Out let Pipe - 350mm dia.DI valves – 2 No’s Over Flow pipe - 350m dia. Scour Pipe - 200mm dia.b) For 800 KL to 1500 Kl ELSRs Inlet Pipe - 400mm dia. Out let Pipe - 450mm dia.DI valves – 2 No’s Over Flow pipe - 450m dia. Scour Pipe - 200mm dia.c) For above 1500 KL to 2500 Kl ELSRsInlet Pipe - 400mm dia. Out let Pipe - 500mm dia.DI valves – 2 No’s Over Flow pipe - 500m dia. Scour Pipe - 200mm dia.Note: Any deviation from the above sizes as per design, shall be paid or recovered.(iii) Manhole Frames & Coversa) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min. of 150mm dia.) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos.v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 Noviii) The staircase shall be enclosed with brick masonry walls on three sides and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement. The Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia. pipe & middle railing of 25mm dia. and verticals with 40mm dia. at an interval not more than of 1.00m c/c.xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No)xii) Lightening Arrestor with all its accessories complete including earthing, with relevant IS Codes - 1 No.xiii) Compound wall: Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall is minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM (1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8) prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Ground level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angular of 25mm X 25mm X 4mm in \"Y\" shape to height of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauges shall be stretched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4)prop on both sides of brick work.Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreasedNote:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL shall be as follows.: i)500 KL : 0.086% ii)1000 KL : 0.047% iii)1500 KL : 0.034% iv)2000 KL : 0.026% v)2500 KL : 0.022 % For intermediate capacities, interpolated percentages shall be adopted.xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 Sqm with the following specification: RCC framed structure with concrete grade not less than M20 design mix at the locations specified by the department at the time of execution with veranda, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases.MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides open able shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall be provided. Septic tank for 5 users shall be provided. |
| 1222 | Construction of Watchman quarters (3 Nos) |
| 1223 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD.Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 1224 | Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 1225 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 1226 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 1227 | column footings |
| 1228 | Columns |
| 1229 | Plinth Beams |
| 1230 | Lintel Beams |
| 1231 | Roof Beams |
| 1232 | Roof slab0.125m thick with 0.30m extension all sides |
| 1233 | Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 1234 | Loft slab 0.075m thick |
| 1235 | Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 1236 | 1st floor |
| 1237 | Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 1238 | Ground floor |
| 1239 | 1st floor |
| 1240 | Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height For ceiling slab area |
| 1241 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 1242 | Supply delivary and fixing RCC Jallis includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 1243 | Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 1244 | Door -D - 1.20X2.10 m |
| 1245 | doorsD1 -1.0X2.10m |
| 1246 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work _windows 1.20x1.20 |
| 1247 | Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work_Toilet door D2 |
| 1248 | Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work_Toilet door D2 |
| 1249 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 1250 | Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 1251 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 1252 | Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 1253 | Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 1254 | Providing Electrification |
| 1255 | Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 1256 | Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 1257 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 1258 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 1259 | supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 1260 | supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 1261 | supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 1262 | Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 1263 | Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete |
| 1264 | Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 1265 | Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 1266 | Supply of 20W tube light luminaire powder coated CRCA sheet steel housing with Electronic Ballast Chokes and all standard accessoriesof makes Wipro / G.E. / Phillips / Crompton / Bajaj. |
| 1267 | Sanitary and water supply |
| 1268 | Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 1269 | Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 1270 | Supplying & Fixing low down porcelain flushing tank 10 Lit Capacity Hindustan Sanitary ware/ parry/ Neycer with internal components |
| 1271 | Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 1272 | Supply of 110 mm dia 3 M single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 1273 | Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 1274 | Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 1275 | Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 1276 | Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 1277 | S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 1278 | 25 mm dia nominal bore -from tank to jn forof individual lines |
| 1279 | 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 1280 | 15 mm dia nominal bore -for internal |
| 1281 | S&F of GI &GM fittings |
| 1282 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 1283 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 1284 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 1285 | S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 1286 | S& F GI union Ist Quality |
| 1287 | 12.70mm |
| 1288 | 19.05mm |
| 1289 | 25.40mm |
| 1290 | For septic Tank |
| 1291 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD.Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth |
| 1292 | Filling with sandin foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 1293 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 1294 | Brick work in CM 1:5 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 1295 | Cement plasteringusing opc in cm(1:4) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 1296 | RCC M-20 Nominal mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shuttering unit 1.00cum for culvert slabs RBR-SBST-5 A |
| 1297 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 1298 | Construction ofSCADA Room 8.00 x 12.00 Size |
| 1299 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side |
| 1300 | Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work (APDSS No.101). (RBR-FNDN |
| 1301 | Laying Cement concrete (1:4:8)using 40mm nominal size HBG metal M/C including cost and conveyance of all materials from approved quarry, machine mixing, vibrating, laying, levelling, ramming, curing and labour charges etc., complete. As per APSS 402 (BL |
| 1302 | Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for c |
| 1303 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 1304 | Supply and placing of the M30 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cu |
| 1305 | Supply and placing of the M30 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cu |
| 1306 | Footings |
| 1307 | Pedastals around Columns |
| 1308 | Columns Up to plinth |
| 1309 | Plinth Beams 300 x 400 |
| 1310 | Columns |
| 1311 | Beams 230 x 500 |
| 1312 | Lintels |
| 1313 | Sunshades |
| 1314 | Staircase |
| 1315 | RCC Slab 150mm thick |
| 1316 | Supplying, fitting and placing High Yield Strength Deformed Steel Bars (HYSD bar) reinforcement in foundation complete as per drawings and technical specifications for Bars below 36 mm dia including over laps and wastage, where they are not welded. (BLD-C |
| 1317 | Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffoldin |
| 1318 | 11.5 cm wide Brick masonry for super-structure on ground floor in cm (1:3) using second class traditional size bricks including cost of all materials, seigniorage charges, labour and all operations for constructing half brick masonry, mixing cement mortar |
| 1319 | Plastering with CM (1:4), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. |
| 1320 | Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. |
| 1321 | Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. |
| 1322 | Flooring with Non Skid Ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, but including the cost of conveyance of all materials |
| 1323 | Flooring with Non Skid Ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, but including the cost of conveyance of all materials |
| 1324 | Dadooing to walls with first quality glazed coloured tiles approved colour of any size set over base coat of C.M(1:3)prop. 12mm thick and neat grey cement slurry of honey like consistency spread at the rate of 3.3Kg of cement per sqm and jointed with neat |
| 1325 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) |
| 1326 | Painting to new walls with 2 coats of water proof cement paint of apporved brand and shade over a base coat of approved cement primer grade I making making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and r |
| 1327 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) |
| 1328 | Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-31 |
| 1329 | Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.6 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of |
| 1330 | Windows: Double shutter3\"-0\" x 4\"-0\"(914.4mm x 1219.2 mm) outer frame section size of46 x 52 mm shutter frame section size of 46 x 46 mm |
| 1331 | Providing & fixing 30 mm thick solid panel PVC door shutter consisting of frame made out of 19 guage M.S tube of 19 x 19 mm for stiles, top & bottom rail, with a coat of primer of approved make. M.S. Frame covered with 5 mm thick heat moulded PVC “C” chan |
| 1332 | Ventilators: Top Hung 4 \"-0\" x 3\"-0\" (1219.2x914.4mm) outer frame section size of 46 x 52m m shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm. |
| 1333 | Internal & External Electrification including S & F of 20mm dia 1.50mm thick PVC Pipe, Wiring with 2 runs of 14/0.3mm (1.0 Sq.mm) Fire Retardant (FR) P.V.C. insulated flexible copper cable (ISI MARK), Supply and fixing of 6A 3 pin wall plug socket with 6A switch control, Supply and fixing of batten holder / slanting holder, Supply and Transportation of 1x36/40W box type tube light luminaire with copper / VPIT Choke, condensor, starters etc.,and 1No 36/40W tube etc., complete. and Labour Charges etc. Complete. |
| 1334 | Supply of 2.0 TR 5 Star capable of delivering not lessthan 21600 BTU/hr and above with operating onrefrigerant R-410A / R-32Makes: As per list of recommended brands ascategory II INVERTER Model Cool type split AC unit with highwall mounted Single Split indoor unit and outdoor condensing unitHermetically sealed compressor suitable for operation on 230V, 50Hz,1Phase AC supply capable of performing Heat cool dehumidifying aircirculating and filtering with cooling and condensing units with 3 mts ofcopper piping, insulation kit and 4 mts of 4 core copper flexible chordwith cordless remote control etc., dual barrier coating in order to protectcoil form oxidation with copper condenser. |
| 1335 | Providing Distribution system with HDPE pipes in Zone - I, II, III, IV & V including higher dia. HDPE casing pipe at drain cross provision |
| 1336 | Cutting open BT road surface as well as asphalt concrete including water bound macadamand stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 1337 | Cutting open C.C. road surface including stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 1338 | Cutting open water bound macadam road including soiling for pipe line trench work. as directed by the departmental officers. |
| 1339 | RBR-FNDN-1- (i-B) - In ordinary soils, by Mechanical meansEarthworkexcavationin all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 1340 | BLD-CSTN-2-5 - (13): Earth work excavation for foundations and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth RBR-EECD-9 (ii) |
| 1341 | RBR-FNDN-1- (i-A) In ordinary soils, by Manual meansEarthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 1342 | RBR-FNDN-1- (iv) - In hard rockblasting prohibited:Excavation in Hard rock (blasting prohibited) Upto 3 m depth including 1.5 m depth in hard rock : Earthwork excavation in hard rock such as sheet rock and boulders in habitant areas where conventional blasting can not be donefor pipe line trenches, including all incidental and operational charges etc., complete. |
| 1343 | Providing barricading arrangement with casurina ballies as per the design duly excavating pits and its removal after the function is over including hire charges of the barricading materials a sper the schedule given by the departmental authorities complete for finished item of work_3-TIER (4 days)_BMS-W.84.F |
| 1344 | Manufacture, supply, delivery of HDPE PE 100 pipes conforming to IS 4984 - 1995 includingtransportation to any where in AP, Excise duty, sales tax etc., complete ( Supply upto 90mm dia in coil & above 90mm dia strightin length in 6M) (6 Kg/Sq Cm) |
| 1345 | 110 mm dia HDPE 6Kg/Cm2 |
| 1346 | 160 mm dia HDPE 6Kg/Cm2 |
| 1347 | 200 mm dia HDPE 6Kg/Cm2 |
| 1348 | 250 mm dia HDPE 6Kg/Cm2 |
| 1349 | 315 mm dia HDPE 6Kg/Cm2 |
| 1350 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to any where in AP, Central excise duty, sale taxetc., complete |
| 1351 | Bends |
| 1352 | 110 mm dia suitable for HDPE 6Kg/Cm2 |
| 1353 | 160 mm dia suitable for HDPE 6Kg/Cm2 |
| 1354 | 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 1355 | 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 1356 | 315 mm dia suitable for HDPE 6Kg/Cm2 |
| 1357 | End caps |
| 1358 | 110 mm dia suitable for HDPE 6Kg/Cm2 |
| 1359 | 160 mm dia suitable for HDPE 6Kg/Cm2 |
| 1360 | 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 1361 | 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 1362 | 315 mm dia suitable for HDPE 6Kg/Cm2 |
| 1363 | Long neck pipe ends |
| 1364 | 110 mm dia suitable for HDPE 6Kg/Cm2 |
| 1365 | 160 mm dia suitable for HDPE 6Kg/Cm2 |
| 1366 | 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 1367 | 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 1368 | 315 mm dia suitable for HDPE 6Kg/Cm2 |
| 1369 | MS flanges to suit HDPE pipes |
| 1370 | 110 mm dia |
| 1371 | 160 mm dia |
| 1372 | 200 mm dia |
| 1373 | 250 mm dia |
| 1374 | 300 mm dia HDPE |
| 1375 | Tees |
| 1376 | 110 mm dia suitable for HDPE 6Kg/Cm2 |
| 1377 | 160 mm dia suitable for HDPE 6Kg/Cm2 |
| 1378 | 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 1379 | 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 1380 | 315 mm dia suitable for HDPE 6Kg/Cm2 |
| 1381 | Lowering, laying, jointing & testing of HDPE Pipe line laid to true alignment and gradiant tohydraulic field test pressure per IS codeincluding cost of water with minimum water lead of 500m (Labour charges only)Outer dia of pipes in mm. |
| 1382 | 110 mm dia HDPE 6Kg/Cm2 |
| 1383 | 160 mm dia HDPE 6Kg/Cm2 |
| 1384 | 200 mm dia HDPE 6Kg/Cm2 |
| 1385 | 250 mm dia HDPE 6Kg/Cm2 |
| 1386 | 315 mm dia HDPE 6Kg/Cm2 |
| 1387 | Manufacure supply of Centrifugally cast (Spun) Ductile Iron pressure pipes for water, gas and sewage with Socket Spigot ends conforming to IS.: 8329/2000 in standard working lengths of 4, 5 5.5 & 6 meter for classification K9 & K7 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating. Rates are ex-factory, excluding transportation, taxes and duties. |
| 1388 | 350 mm dia DI K7 |
| 1389 | 300 mm dia DI K7 |
| 1390 | 400 mm dia DI K7 |
| 1391 | Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. |
| 1392 | DI. D/F Sluice valves ofPN.1.6 class |
| 1393 | 100mm dia Sluice Valves |
| 1394 | 150mm dia Sluice Valves |
| 1395 | 200mm dia Sluice Valves |
| 1396 | 250mm dia Sluice Valves |
| 1397 | 300mm dia Sluice Valves |
| 1398 | 350mm dia Sluice Valves |
| 1399 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12orequivalent gradeasperI.S.3896-part2-1985 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality.SEpoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN.1.6 class |
| 1400 | 80mm |
| 1401 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13 / IS 9523 / 2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1402 | Manufacture, supply and delivery of DuctileIron pipes and fittings (spls.) conforming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988 at site of work anywhere in A.P.including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. |
| 1403 | Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint),excluding the cost of the gasket but including all sundries filling with water,with a water lead up to 500m and testing to required pressure, etc.complete (Reference to specifications IS 3114 / 1994 / 12888 / 1997) |
| 1404 | 350 mm dia DI K7 |
| 1405 | 300 mm dia DI K7 |
| 1406 | 400 mm dia DI K7 |
| 1407 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications.BIS No.3114/1994) |
| 1408 | 350 mm dia DI K7 |
| 1409 | 300 mm dia DI K7 |
| 1410 | 400 mm dia DI K7 |
| 1411 | PHE-CISV-15 : Lowering, keeping in position and fixingD.I. sluice valves (with cap / with hand wheel & reflex valves)includingcost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 1412 | 100mm dia Sluice Valves |
| 1413 | 150mm dia Sluice Valves |
| 1414 | 200mm dia Sluice Valves |
| 1415 | 250mm dia Sluice Valves |
| 1416 | 300mm dia Sluice Valves |
| 1417 | 350mm dia Sluice Valves |
| 1418 | PHE-JCIF-5-: Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1419 | 100mm dia Sluice Valves |
| 1420 | 150mm dia Sluice Valves |
| 1421 | 200mm dia Sluice Valves |
| 1422 | 250mm dia Sluice Valves |
| 1423 | 300mm dia Sluice Valves |
| 1424 | 350mm dia Sluice Valves |
| 1425 | Labour charges for fixing Kinetic Air ValvesDouble Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 1426 | 80mm |
| 1427 | Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 1428 | Up to200 MM dia valves |
| 1429 | Up to200 to 350 MM dia valves |
| 1430 | Supply and filling with crusher dust complying with standard specifications with all leads and lifts in layers consolidating with watering and ramming including cost and conveyance of all materials and labour charges, all taxes, seignorage charges, conveyance of sand including loading, unloading etc., complete as per SS and as directed by the departmental officer in charge of the work for restoration of Road. |
| 1431 | Construction ofun-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. RBR-CCPV-5 for CC Road Restoration |
| 1432 | Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100Pipe including lowering, laying and jointing including earth work excavation and refilling the pipe line trench after layingthe pipe lineand including cost of 15mm dia meter & casing pipe of 32mm HDPE of BIS standard and construction of meterchamberetc complete and transferring of house service connection as directed by departmental officer for finished item of work. |
| 1433 | Providing house service connections at house holds side in earthern roads |
| 1434 | Providing house service connections at other side in earthern roads |
| 1435 | Providing house service connections at otherside in BT &CCroads |
| 1436 | Providing house service connections at HHside in BT &CCroads |
| 1437 | Providing DMA Management for reservoir automation and 24 X 7 Watersupply in Amadalavalasa Municipality |
| 1438 | 24 x 7 Water Supply ::DMA Management :: |
| 1439 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 1440 | 200MM Dia Above Specification. |
| 1441 | Inlet of DMA-4 under 600 KL ELSR at Municipal office in Zone-4 |
| 1442 | 300MM Dia Above Specification. |
| 1443 | Inlet of DMA-1,2&3 under 600 KL ELSR at Municipal office in Zone-4 |
| 1444 | Supply and deliveryof Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 1445 | 200MM Dia Above Specification. |
| 1446 | Inlet of DMA-4 under 600 KL ELSR at Municipal office in Zone-4 |
| 1447 | 300MM Dia Above Specification. |
| 1448 | Inlet of DMA-1,2&3 under 600 KL ELSR at Municipal office in Zone-4 |
| 1449 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 1450 | 200MM Dia Above Specification. |
| 1451 | Inlet of DMA-4 under 600 KL ELSR at Municipal office in Zone-4 |
| 1452 | 300MM Dia Above Specification. |
| 1453 | Inlet of DMA-1,2&3 under 600 KL ELSR at Municipal office in Zone-4 |
| 1454 | Supply and delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1455 | 200MM Dia Above Specification. |
| 1456 | Inlet of DMA-4 under 600 KL ELSR at Municipal office in Zone-4 |
| 1457 | 300MM Dia Above Specification. |
| 1458 | Inlet of DMA-1,2&3 under 600 KL ELSR at Municipal office in Zone-4 |
| 1459 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 1460 | Inlet of DMA-1, 2 ,3under 600 KL ELSR at Municipal office Zone-4 |
| 1461 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 1462 | Inlet of DMA-1, 2 ,3under 600 KL ELSR at Municipal office Zone-4 |
| 1463 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1464 | Inlet of DMA-1, 2 ,3under 600 KL ELSR at Municipal office Zone-4 |
| 1465 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1466 | Inlet of DMA-1, 2 ,3 under 600 KL ELSR at Municipal office Zone-4 |
| 1467 | Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1468 | Inlet of DMA-1, 2 ,3 under 600 KL ELSR at Municipal office Zone-4 |
| 1469 | Providing, Installing and satisfactory field testing of Self Powered Presuure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 1470 | Pressure points at Highest Point, Lowest Point & Furthest Point |
| 1471 | Inlet of DMA-1, 2 ,3 under 600 KL ELSR at Municipal office Zone-4 and DMA-4 |
| 1472 | Under 200 KL ELSR at Timmapuram in Zone-1 |
| 1473 | Under 600 KL ELSR at Mettakavalasa in Zone-5(A) |
| 1474 | Under 500 KL ELSR at Chintada in Zone-6 |
| 1475 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1476 | Inlet of DMA-1, 2 ,3under 600 KL ELSR at Municipal office Zone-4 |
| 1477 | Providing AMI Water Meter Management for reservoir automation and 24 X 7 Watersupply in Amadalavalasa Municipality |
| 1478 | AMI Water Meter Management. |
| 1479 | Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-A. |
| 1480 | Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoTin every 24 Hours without fail through the provider registered inDOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication)The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warrantiesand submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-B |
| 1481 | Under DMA-1,2 & 3under 600 KL ELSR atMunicipal office Zone-4 with above specifications |
| 1482 | Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer. |
| 1483 | Providing Instrumentation and Automation of the Pumping System, Reservoir Inlet Management & Supervisory Control and Data Acuasation System (SCADA)for reservoir automation and distribution of 24 X 7 Watersupply in Amadalavalasa Municipality |
| 1484 | Instrumentation and Automation of the Pumping System: |
| 1485 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 1486 | For Raw Water Pumping Station as per the above specification |
| 1487 | For Clear Water Pumping Station as per the above specification |
| 1488 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1489 | For Raw Water Pumping Station as per the above specification |
| 1490 | For Clear Water Pumping Station as per the above specification |
| 1491 | Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer |
| 1492 | DN 100 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification |
| 1493 | DN 150 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification |
| 1494 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 1495 | 300MM Dia Above Specification. |
| 1496 | outlet of Raw Water Pumping Station at Vamsadhara river |
| 1497 | Outlet of Clear Water Pumping main at Vamsadhara river |
| 1498 | Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 1499 | Raw Water Inlet of Water Treatment plant |
| 1500 | Clear Water outlet of Water Treatment plant |
| 1501 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 1502 | Raw Water Inlet of Water Treatment plant |
| 1503 | Clear Water outlet of Water Treatment plant |
| 1504 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 1505 | Raw Water Inlet of Water Treatment plant |
| 1506 | Clear Water outlet of Water Treatment plant |
| 1507 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 1508 | Clear Water outlet of Water Treatment plant |
| 1509 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1510 | Raw Water Inlet of Water Treatment plant |
| 1511 | Clear Water outlet of Water Treatment plant |
| 1512 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 1513 | Raw Water inlet and clear water outlet at WTP |
| 1514 | Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 1515 | For Raw Water Pumping Station as per the above specification |
| 1516 | For Clear Water Pumping Station as per the above specification |
| 1517 | Logic for RTU opeartaions:1. RTU panel for local operaion of the pumps in manual and Auto Mode.2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables.3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves.5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned.6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves.7. In manual opeartion, all the equiment can be run through PLC panel by individual operations.8.The RTU connected with SCADA for remote monitoring and operation.9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge. |
| 1518 | Reservoir Inlet Management :: |
| 1519 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 1520 | 100MM Dia Above Specification. |
| 1521 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1522 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1523 | 150 MM Dia Above Specification. |
| 1524 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1525 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1526 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1527 | 250 MM Dia Above Specification. |
| 1528 | Inlet of 250 KL Existing GLSR |
| 1529 | Inlet of 364 KL Existing GLSR |
| 1530 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 1531 | 100MM Dia Above Specification. |
| 1532 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1533 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1534 | 150 MM Dia Above Specification. |
| 1535 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1536 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1537 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1538 | 250 MM Dia Above Specification. |
| 1539 | Inlet of 250 KL Existing GLSR |
| 1540 | Inlet of 364 KL Existing GLSR |
| 1541 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 1542 | 100MM Dia Above Specification. |
| 1543 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1544 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1545 | 150 MM Dia Above Specification. |
| 1546 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1547 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1548 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1549 | 250 MM Dia Above Specification. |
| 1550 | Inlet of 250 KL Existing GLSR |
| 1551 | Inlet of 364 KL Existing GLSR |
| 1552 | Supply and delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1553 | 100MM Dia Above Specification. |
| 1554 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1555 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1556 | 150 MM Dia Above Specification. |
| 1557 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1558 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1559 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1560 | 250 MM Dia Above Specification. |
| 1561 | Inlet of 250 KL Existing GLSR |
| 1562 | Inlet of 364 KL Existing GLSR |
| 1563 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1564 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1565 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1566 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1567 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1568 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1569 | Inlet of 250 KL Existing GLSR |
| 1570 | Inlet of 364 KL Existing GLSR |
| 1571 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 1572 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1573 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1574 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1575 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1576 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1577 | Inlet of 250 KL Existing GLSR |
| 1578 | Inlet of 364 KL Existing GLSR |
| 1579 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 1580 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1581 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1582 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1583 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1584 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1585 | Inlet of 250 KL Existing GLSR |
| 1586 | Inlet of 364 KL Existing GLSR |
| 1587 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 1588 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1589 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1590 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1591 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1592 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1593 | Inlet of 250 KL Existing GLSR |
| 1594 | Inlet of 364 KL Existing GLSR |
| 1595 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1596 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1597 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1598 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1599 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1600 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1601 | Inlet of 250 KL Existing GLSR |
| 1602 | Inlet of 364 KL Existing GLSR |
| 1603 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 1604 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1605 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1606 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1607 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1608 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1609 | Inlet of 250 KL Existing GLSR |
| 1610 | Inlet of 364 KL Existing GLSR |
| 1611 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1612 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1613 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1614 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1615 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1616 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1617 | Inlet of 250 KL Existing GLSR |
| 1618 | Inlet of 364 KL Existing GLSR |
| 1619 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1620 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1621 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1622 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1623 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1624 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1625 | Inlet of 250 KL Existing GLSR |
| 1626 | Inlet of 364 KL Existing GLSR |
| 1627 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1628 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1629 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1630 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1631 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1632 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1633 | Inlet of 250 KL Existing GLSR |
| 1634 | Inlet of 364 KL Existing GLSR |
| 1635 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 1636 | Inlet of 250 KL Proposed ELSR at Municipal office |
| 1637 | Inlet of 200 KL Existing ELSR at Housing colonies |
| 1638 | Inlet of 600 KL Proposed ELSR at Mettakavalasa |
| 1639 | Inlet of 500 KL Proposed ELSR at Chinthada |
| 1640 | Inlet of 600 KL Proposed ELSR at GJ college |
| 1641 | Inlet of 250 KL Existing GLSR |
| 1642 | Inlet of 364 KL Existing GLSR |
| 1643 | Local SCADA Control Sation: |
| 1644 | Establishment of HARDWARE for Individual Local Control Station at Individual ULB :: |
| 1645 | Supply,erection, testing, commissioning of Hard ware for the SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter managementwhere the instrumantation and automation developed under this project and synchornization by deploying the followingcomponents including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. |
| 1646 | Desktop PC Station with specification of I7Processor, 8 GB Ram, ,512 GB SSD,Licensed OS, 21\" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL |
| 1647 | 55\" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screenswith required cables and connectors etc., complete. |
| 1648 | Modem with specifications of Fibre Port having ILL, PON &Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider |
| 1649 | 3 KVA Stabilizer with specifications of 220 V.ACInput/ 220 V.AC output, necessary terminal wires etc., complete complete |
| 1650 | 3 KVA online ups with specifications of 220 V.ACInput/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank,make ofVertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete |
| 1651 | 3 in one on line B/W A4 Lazer Jet printer |
| 1652 | Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication |
| 1653 | Establishment of Local SCADA station at Amadalavalasa Municipality with the above specifications. |
| 1654 | Development of Softwares for Individual Local Control Station at Individual ULB :: |
| 1655 | Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. |
| 1656 | Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user) |
| 1657 | Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. |
| 1658 | Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customerat the time of commissioning |
| 1659 | Develop, Supply, install and commissioning of Anroid & IO\"s application for data monitoring by through Mobi-APP as required by the customerat the time of commissioningcomplete |
| 1660 | Establishment of Local SCADA station at Amadalavalasa Municipality with the above specifications. |
| 1661 | Providing for Implementation of Environmental Management Plan |
| 1662 | Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 1663 | Noiselevel(5 Monitoringstation)onceinamonthforthree seasonsduring the constructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 1664 | Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 1665 | Hiring for 2 number of vehicles for 24 Months on execution period at Rs.35000/- per Month. |
| 1666 | OPERATION & MAINTENANCE COST (Excluding Energy charges) of AMADALAVALASA MUNICIPALITY for Seven Years including two years defect liability period |
| 1667 | Man Power |
| 1668 | Personal required for operating Intake/Offtake well/Pump houses |
| 1669 | Operator |
| 1670 | Fitter/Helper |
| 1671 | Watch man |
| 1672 | Personal required at operating Clear water rising mains |
| 1673 | Fitter/Helper |
| 1674 | Personal required at operating Service reservoirs |
| 1675 | Watch man |
| 1676 | Personal required at operating distribution system |
| 1677 | Fitter/Helper |
| 1678 | Consumables for 7 years |
| 1679 | A) Chlorine gas for Disinfection @ 3 mg/Lt |
| 1680 | Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines. |
| 1681 | B) Alumino -Ferric (Alum) @ 20 mg/Lt |
| 1682 | Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit |
| 1683 | Repairs to pumpsets & Water pipe lines(2 years after execution period) |
| 1684 | i) Replacement of bearings of pumpsets |
| 1685 | ii) Replacement of sleeves |
| 1686 | iii) Rewinding of Motors |
| 1687 | iv) Raw Water Motors |
| 1688 | Clear Water Motors |
| 1689 | iv)Replacement of glands of sluice valves |
| 1690 | v) Replacements of balls of Air valves |
| 1691 | vi) Greease |
| 1692 | vii) Gland Packing |
| 1693 | LEAKAGES |
| 1694 | Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete |
| 1695 | 315 mm HDPE Pipes |
| 1696 | 250 mm HDPE Pipes |
| 1697 | 200 mm HDPE Pipes |
| 1698 | 160 mm HDPE Pipes |
| 1699 | 110 mm HDPE Pipes |
| 1700 | Monitoring Costs : Operation Phase ( One year) |
| 1701 | Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 1702 | Noiselevel(5Monitoringstation)onceinamonthforthree seasonsduring the constructionperiodat intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 1703 | Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 1704 | Compensatory plantation andthree years maintenance (Compensatory afforestation ratio is 1:5) |
| 1705 | Sprinkling of wateronce in a day fortwo years (excluding rainy days):500 days @ Rs.1000/trip |
| 1706 | OPERATION & MAINTENANCE COST - CENTRAL SCADA at CIRCLE LEVELfor Seven Years including two years defect liability period |
| 1707 | Application Engineer (Graduate Engineer)Rate as per Labour Rates LAB-00130 ofCSSR 2025-26 |
| 1708 | System Engineer (Diploma Engineer)Rate as per Labour RatesLAB-00130 ofCSSR 2025-26 |
| 1709 | Sr. Service Engineer(Graduate Engineer )Rate as per Labour Rates LAB-00130 of CSSR 2025-26 |
| 1710 | Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-26 |
| 1711 | Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 |
| 1712 | II) MAINTAINANCE OF LOCAL CONTROL STATION : |
| 1713 | BSNL Charges for static IP |
| 1714 | Data base management for WEB reporting |
| 1715 | Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
| 1716 | OPERATION & MAINTENANCE COST - LOCAL SCADA at Amadalavalasa Municipalityfor Seven Years including two years defect liability period |
| 1717 | Jr. Service Engineer(Diploma Engineer)Rate as per Labour Rates LAB-00127 of CSSR 2025-26 |
| 1718 | Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-26 |
| 1719 | Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 |
| 1720 | Hiring of vehicle (4 wheeler)Rate as per G.O.MS.No.87Dated 01-06-2017. |
| 1721 | II) MAINTAINANCE OF LOCAL CONTROL STATION : |
| 1722 | Replacement of necessary servicable materials(Reagents) for Chlorine Analysers*Each Reagent bottle willwork for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. |
| 1723 | Clear Water outlet near Vamsadhara River Source at Alamajipeta HWWInlet of 200 KL ProposedELSR at TimmapuramInlet of 600KL Proposed ELSR at Municipal OfficeInlet of 600KL Proposed ELSR at MettakavalasaInlet of 500KL Proposed ELSR at ChintadaInlet of 500KL Existing ELSR at VenkayyapetaInlet of 1200KL Existing GLSR at DanarasimetaInlet of 364KL Existing GLSR at DanarasimetaInlet of 250KL Existing GLSR at DanarasimetaInlet of 200KL Existing GLSR at Timmapuram |
| 1724 | Replacement of necessary tranducers for PH analysersClear Water outlet of Vamsadhara River Source and Nagavali River Source |
| 1725 | Replacement of necessary tranducers for Turbidity analysersClear Water outlet of Vamsadhara River Source and Nagavali River Source |
| 1726 | BSNL Charges for static IP |
| 1727 | GPRS Connections |
| 1728 | WTP Quality Management |
| 1729 | ELSR Management |
| 1730 | DMA Management |
| 1731 | Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
| 1732 | Palakonda Nagar Panchayt |
| 1733 | 3.1 Construction of Infiltration well No.1 & 2 with 4 m Dia in NagavaliRiver at Sankili near the existingWater works. |
| 1734 | 3.1.1 Supply, delivery, fabrication and erection of cutting toe for well curb with ISA 150x150x12mm including cost and conveyance to work spot including all labour charges for fabrication and erection etc.,complete as directed by the departmental authorities. |
| 1735 | 3.1.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cum - mechanical means upto 3.00mts depth |
| 1736 | 3.1.3 Well sinking in sandy and other loose soils under water either by manual labour, divers, or dredgers, weighing the top of steining to assist sinking etc., including dewatering and other incidental charges such as hire charges for mechanical equipment etc,complete for an internal dia of 4.00mts |
| 1737 | a) Up to 2.00mts depth |
| 1738 | b) 2.00mts to 4.00mts depth |
| 1739 | c) 4.00mts to 6.00mts depth |
| 1740 | d) 6.00mts to 8.00mts depth |
| 1741 | e) 8.00mts to 8.70mts depth |
| 1742 | 3.1.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc-M30 |
| 1743 | a) Well Curb |
| 1744 | b) Side walls (Well Steining) |
| 1745 | c) Well top cover slab 200 mm thick. |
| 1746 | 3.1.5 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade and above as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 1747 | 3.1.6 Providing invert filter media with following sizes of metal including cost of material, laying charges etc., complete |
| 1748 | a) 40 mm Metal |
| 1749 | b) 2 to 20 mm metal |
| 1750 | 3.1.7 Supply and fixing of 32 mm dia PVC / 10 Kg / Sq. Cm pipe for weep holes @ 300 mm C/C staggered spacing including cost and conveyance of all materials and all labour charge for fixing in staining wall etc., complete as per S.S and directed by the departmental authorities |
| 1751 | BILL NO. 3.2 Construction of 600 mm dia Infiltration gallery from Infiltration Well No.1 to 2 to proposed collection well cum Pump House & connecting infiltration gallery from existing collection well to proposed collection well cum Pump house in Nagavali River near the existing Water works at Sankili. |
| 1752 | 3.2.1 Excavation of trenches for infiltration galleries and connecting mains in all soils under water including all leads, lifts, shoring, strutting, bailing out water and removal of shoring and strutting materials after completion of pipe line work. |
| 1753 | a) 0.00 to 1.00 m depth |
| 1754 | b) 1.00 to 2.00m deep |
| 1755 | c) 2.00 to 5.00mdeep |
| 1756 | d) 5.00 to 6.00 m deep |
| 1757 | e) 6.00 to 7.00 m deep |
| 1758 | 3.2.2 Manufacture, supply and delivery of 600mm dia. S/S RCC NP3 class perforated pipes for Infiltration gallery including cost and conveyance to work spot and handling charges providing perforated holes including all taxes and duties etc., complete as per S.S |
| 1759 | 3.2.3 Lowering, laying and jointing of 600mm dia. RCC perforated pipes of NP3 class inclusive of bailing out water and jointing with cement fillets, and all other incidental charges for infiltration gallery inclusive of bailing out water by pumping to keep the trench reasonably dry to fecilate the work excluding cost of perforated pipes and collars. |
| 1760 | 3.2.4 Providing and construction of transition cum filter media using approved or recommended material i.e., 230mm thick 230mm thick 40-20mm C.A, 230mm thick 20-12mm C.A, 230mm thick 12-6mm C.A, 230mm thick Coarse sand and 400mm thick fine sand satisfying the filter criteria including machinery, labour, laying each layer to required slope, compaction etc., complete with all extra leads and de liftsdirected by the departmental authorities. |
| 1761 | a) 40 mm to 20mm size Coarse aggregate |
| 1762 | b) 20 mm to 12 mm size Coarse aggregate |
| 1763 | c) 12 mm to 6 mm size Coarse aggregate |
| 1764 | d) Coarse sand |
| 1765 | e) Fine sand |
| 1766 | BILL NO. 3.3 Construction of 6.0 mts dia RCC collection well cum Pump House in Nagavali River near the existingWater works at Sankili. |
| 1767 | 3.3.1 Supply, delivery, fabrication and erection of cutting toe for well curb with ISA 150x150x12mm including cost and conveyance to work spot including all labour charges for fabrication and erection etc.,complete as directed by the departmental authorities. |
| 1768 | 3.3.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthby mechanical means |
| 1769 | 3.3.3 Well sinking in sandy and other loose soils under water either by manual labour, divers, or dredgers, weighing the top of steining to assist sinking etc., including dewatering and other incidental charges such as hire charges for mechanical equipment etc,complete for an internal dia of 6.00mts |
| 1770 | a) Up to 2.00mts depth |
| 1771 | b) 2.00mts to 4.00mts depth |
| 1772 | c) 4.00mts to 6.00mts depth |
| 1773 | d) 6.00mts to 8.00mts depth |
| 1774 | e) 8.00mts to 10.00mts depth |
| 1775 | f) 10.00 mts to 11.00 mts depth |
| 1776 | g) 11.00 mts to 11.80 mts depth |
| 1777 | 3.3.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc-M30 |
| 1778 | a) Well Curb |
| 1779 | b) Side walls (Well Steining) |
| 1780 | i) Well 1 |
| 1781 | ii) Well 1 |
| 1782 | c) Well top cover slab 200 mm thick. |
| 1783 | 3.3.5 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade and above as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 1784 | 3.3.6 Providing invert filter media with following sizes of metal including cost of material, laying charges etc., complete |
| 1785 | a) 40 mm Metal |
| 1786 | b) 12 to 20 mm metal |
| 1787 | 3.3.7 Supply and fixing ofStainless steel Ladder made out of suitable sections for access from Infiltration well top slab to Bottom |
| 1788 | 3.3.8 Supply and fixing of MS Structural Steel including cost and conveyance to work spot including two coats of anti corrossive black painting including all labour charges for cutting and placing in position etc.complete as per S.S |
| 1789 | 3.3.9 Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site, seignorage charges and labour charges for mixing of mortar, plastering and curing etc., complete as per S.S |
| 1790 | 3.3.10 Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work |
| 1791 | 3.3.11 Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities |
| 1792 | 3.3.12 Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 1793 | 3.3.13 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-30 |
| 1794 | 3.3.14 Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 1795 | 3.3.15 Supply, delivery, lowering and keeping in position of 600mm diaDI D/F Gate Valve (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4.All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. The rate including cost, CST, Excise duty and conveyance to work spot and stacking care fully at site etc.complete as per S.S PN 1.6 |
| 1796 | 3.3.16 Supply and delivery of 600mm dia. centrifugally cast (spun) Ductile Iron tail piece fitting with required flanged (welded) ends and socket end confirming to specification No.IS 8329/2000 with cement lining inside the pipe, out side Zinc coating including cost of fitting, VAT and other duties. The rate including transportation and conveyance to work spot and fixing in position etc., complete as per S.S and as directed by the departmental authorities for finished item of work. |
| 1797 | 3.3.17 Supply and delivery of SS/C.I/M.S 12.00m. long operating handle with rod & wheel for operation of D.I. Sluice valve inside the intake well as per the actuals and as directed by the departmental authorities. |
| 1798 | 3.3.18 Providing MS hand railing made out of suitath MS angles and GI pipe including cost and conveyance of material and fabrication charges and painting as per SS and as directed by the engineer in charge of the work. |
| 1799 | 3.3.19 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chagesunit 1.00 Rmt BLD-ELEC-1-4 |
| 1800 | 3.3.20 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages unit 1.00 Rmt BLD-ELEC-1-4 |
| 1801 | 3.3.21 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building- for 6 pointsunit eachBLD-ELEC-2-1 |
| 1802 | 3.3.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges unit each BLD-ELEC-2-1-3 |
| 1803 | 3.3.23 Supply andrun of 2 of36/0.3 mm. (2.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges etc.,unit 1.00 rmtBLD-ELEC-3-1- |
| 1804 | 3.3.24 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. unit 1.00 rmtBLD-ELEC-3-1-2 |
| 1805 | 3.3.25 supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,unit 1.00 rmtBLD-ELEC-6-1-4 |
| 1806 | 3.3.26 Providing independent earthing by excavating a trench toa depyh of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc completeunit eachBLD-ELEC-5-1-1 |
| 1807 | 3.3.27 Supply and fixing SPN Distribution board with IP-30 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete. BLD-ELEC-4-4.1 |
| 1808 | 3.3.28 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 1809 | 3.3.29 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 1810 | 3.3.30 Supply of 9\" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT |
| 1811 | 3.3.31 Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 -260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix /Jaquar /HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonic/Ecolink/Capart. b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG. MAT- 03351 |
| 1812 | 3.3.32 Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 1813 | 3.3.33 Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete |
| 1814 | 3.3.34 Labour charges Fixing of 20W tube light luminaire on wall / Ceiling with/ TW round blocks with all accessories including giving connections and all labour charges etc., complete. |
| 1815 | BILL NO. 3.4 Construction of Foot Bridge from collection well cum Pump House to the bund near the the exisitng Head Works at Sankili for a length of 25 mts. |
| 1816 | 3.4.1 Drilling of 300 mm Dia Pile with Augar Boring In Sandy Soilby Operation including Hire and Operational Charges of Drilling equipment and Labour charges for a depth of 10mts including insertion of MS Liner Pipe in Pile for 10 mts depth on average. Augoring and boring of holes in site for Bored cast-in-situ R.C.C. Piles for building foundations in loamy, clayey soils like Black cotton soils and ordinary soils without under reams as per IS 2911 - 1980 as per approved designs including all operations, incidental, labourcharges, hire charges of machinery, augur bore drill and shell equipment, etc, complete for all depths and for finished item of work for piles unit 1.00 Rmt - Revised standard data- Item -20-a |
| 1817 | 3.4.2 Supply,and Delivery of 6 mm thick 300 mm dia M.S.Liner Pipe for inserting in the Pile in Sandy Soil to an average Depth of 10 mts. (3.14x0.306=0.961) |
| 1818 | 3.4.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1I-B by mechanical means |
| 1819 | 3.4.4 Plain Cement concrete (1:4:8) using 40 mm metal with concrete mixture.All work upto plinth level. unit 1.00 cum - BLD-CSTN-2-5 |
| 1820 | 3.4.5 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30 |
| 1821 | a) Piles Concrete (No Centering Charges are required) |
| 1822 | b) Pile Caps |
| 1823 | c) Longitudinal connecting Pile Caps |
| 1824 | d) Width wise connecting(Cross Beams) |
| 1825 | e) Columns above Pile Caps |
| 1826 | f) Bracing Beams connecting columns at 3mts |
| 1827 | g) For RoofBeams Longitudinal connecting Columns |
| 1828 | h) For Roof Beams Width wise connecting Columns |
| 1829 | i) For Roof slab of 150mm Thick |
| 1830 | 3.4.6 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GFuding cost of binding wire etc. complete as per SS but Excluding all taxes |
| 1831 | 3.4.7 Providing Hand railing with M.S.Angles of 50x50x8mm size kept at 2mts intervals fixed Vertically for a height of 75cm above slab level, placing 20mm size GI Pipes Horizantally connecting the Verical Angle Posts 4 Rows at 150mm c to c including cost and conveyance of all materials,fabrication, Boring Holes of 20mm dia for each vertical post for 4 nos for running the Pipeline,Proving Enamel Painting Two Coats of selected colour over a primary coat of Red Oxide |
| 1832 | 3.4.8 Plastering with CM (1:3) 12mm thick including cost & conveyance of all materials, labour charges etc, completefor finished item of work |
| 1833 | 3.4.9 Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 1834 | 3.4.10 Whiting withsnowcem intwo coats including cost & conveyance of all materials, labour charges etc, completefor finished item of work |
| 1835 | BILL NO. 3.5 Providing Approach CC Road from Approach Bridge to Connecting Rajam to Palakonda BT Road |
| 1836 | 3.5.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B - Meachanical means |
| 1837 | 3.5.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A - manual means |
| 1838 | 3.5.3 Collection and spreading ofstone crusher dust including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work. RBR-FNDN-2(1) |
| 1839 | 3.5.4 Construction ofun-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. RBR-CCPV-5 |
| 1840 | 3.5.5 Collection, supply and spreaing of good red gravel from appoved quarry and filling the same on the proposed road sholder surface and ramming with hand rollerand all labour charges and other incidental charges etc., complete as per SS and as directed by the departmental officer incharge of the work.RBR - FNDN - 2 / ii |
| 1841 | BILL NO. 3.6 Supply, delivery, and erection of clear water Vertical turbine Pumpsetshaving a discharge of 47 lps against a head of 69 mts of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformet to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete( 3 Nos.- 45 KW) in the collection well cum Pump House near the exisitng water works at Sankili for pumping water to the existing 400 KL ELSR & proposed 500 KL ELSRs at Municipal Office, proposed 500 KL ELSR at Venkammapeta, proposed 500 KL ELSR at NK Rajapuram & proposed 500 KL ELSR at Vadama(R&B Bunglow) |
| 1842 | 3.6.1 Providing Raw Water Pumping system at Nagavali river by supply, delivery and erection ofVT pump set with specifications ofHead range of 69 mtrs, discharge of 169 M3/Hr for clear Water(2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 1843 | Supply and Delivery of Verticle Turbine (VT) Pump set: Supply, erection, testing and commissioning ofVertical Turbine pump ( VT pump set) with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing and belmouth with cast iron, impeller, shaft sleeves,muff coupling units-CF-8M ,shaftSleeves and wearings withbronze, shaft with SS410, throdenbering with Bronze with rubber lined, suitable shaft sealing system with stuffing box arrangement, provison for , fixing of suitable diapressure guages with Gliseron filling and the pump driven withLT Squirrel cage inductionDrive rated Motor (Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM suitable for pump selection solid shaft TEFC enclosure, IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Coupling, coupling guard and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractor - 1.00 Unit. ii Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to |
| 1844 | true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing.- 1.00 Unit. iii) Internal Pipe lines: Deviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance. - 1.00 Set Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.C.fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header. - 1.00 Set. Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and |
| 1845 | fixing following components complete- 1.00 Set i) Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer - 1 No. ii) Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare - 2 No\"s, iii) Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station - 1 Set, iv) ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps - 2 Sets, v) Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panel - 1 Set., Supply, laying, termination and testing suitable capacity of1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) - 1 Lot, Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete. - 1 Lot. Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc; - 1 Set - i) Ring Spanner 3/16 to 1\" - 1 No., ii) Double end spanner set 3/16\" to 1\" - 1 No., iii) Pipe Wrench 18\" & 4\" - 2 No\"s, iv) Screw drivers 6\", 10\" & 12\" - 3 No\"s, v) Cutting Plier 12\" - 1 No., vi) 2 Kgs Hammer with Handle - 1 No., |
| 1846 | vii) Nose Plier - 1 No., viii) Flat and Half round smooth file - 2 Sets, ix) Adjustable Spanner 6\" - 1 Set, x) Column pipe Clamps - 2 Pair, xi) Line Shaft Clamps - 1 Pair, xii) Line rope and clamps double the weight of pump - 2 Sets, xiii) Gland thghtening Spanner - 1 No., xiv) Spitter removing Spanner - 1 No., Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete - 1 Set- i) Fire extiguisher 3Kg capacity - 2 No\"s, ii) Rubber Mat 6\" x 4\" - 2 No\"s, iii) Fire Buckets with stand and three buckets - 1 No., iv) Rubber Hand Gloves - 1 Set, v) Danger Board Plates - 4 No\"s, vi) First aid kit with chart - 1 No, vii) Shock Treatment Chart - 1 No., viii) Portable rechargeble torch light - 1 No., ix) Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc; - 1 No., Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc., - 1 Set, All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field Engineer - 1 Set, Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection - 1 Job |
| 1847 | 3.6.2 Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector control - 1 Set, Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder - 1 Set, Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder - 1 Set, Power transformer, required push buttons and MFM for each Main pump feeder - 1 Set |
| 1848 | BILL NO. 3.7 Supply, delivery , erection and commissioning of 250 KVA Transformer near the the exisitng Water Works at Sankili. |
| 1849 | 3.7.1 Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 1850 | 3.7.2 Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 1851 | 3.7.3 Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 1852 | 3.7.4 Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 1853 | 3.7.5 Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 1854 | 3.7.6 Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 1855 | 3.7.7 Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 1856 | 3.7.8 Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 1857 | 3.7.9 Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 1858 | a) Earth Electrodes |
| 1859 | b) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 1860 | c) Epoxy insulators |
| 1861 | d) No.\"8\" SWG Copper wire. MAT 04141 |
| 1862 | 3.7.10 Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-04044c 250KVA- 1. Quantity : 1, 2. Rated KVA :250 KVA, 3. Service & Location: Continuous Outdoor Distribution Transformer, 4. Mounting : Plinth, 5. Wound : CopperDouble wound. 6. Type :Core type oil immersed, 7. Cooling : ONAN, 8. TempRise : 40⁰C in oil 45⁰C by resistance, 9. Vector Group: Dyn 11, 10. Primary Connection :Delta, 11. Nominal Voltage / Current : ______, 12. Highest system Voltage: 12000V, 13. Primary Frequency :50 HZ +/- 3%, 14. Number of Phases : 3, 15. Primary wires: 3, 16. Secondary connection : Star, 17. SecondaryVolts / Current :433V, 18. Secondary phases : 3,19. Secondary wires: 4,20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps),21. Terminal arrangement- a.HV: HT terminal box as per the site condition.b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable,22. LV:One separate terminal for earthing.,23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats, |
| 1863 | 24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats,25. Percentage Impedance at 75 deg C AT 4.5,26. No load Current Less than 2% of full load Current, 27. Standrad Fittings & Accessories.a. Rating and terminal marking plate: One, b. Lifting Lugs:Two,c. Off-circuit tap switch :One,d. EarthingTerminals :Two, e. Radiators ( Attachable):Adequate,f.Explosion vent with Diaphragm :One,g. Conservator with Drain plug:one, h. Oil filling hole with cap :One, i.Oil level indicator : One,j.Dehydrating Silicagel Breather : One, k. Terminal Arrangement: HV With Terminal Box, l. Terminal Arrangement : LV Cable Box, m. Separate Neutral Bushing: One,n. Filter valve with blanking plate : One, o. Drain cum filter valve with blanking plate : One , p. Air release device : One, q. Thermometer Pocket : One,r. Four :Unidirectional flat rollers, s. One :10Cm dial thermometer(Rigid stem type) |
| 1864 | 3.7.11 Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 1865 | 3.7.12 LT Panel |
| 1866 | a) Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 1867 | b) Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 1868 | 3.7.13 Incoming |
| 1869 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1870 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 1871 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 1872 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 1873 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 1874 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 1875 | g).3RYB Phase indication lamps with leds |
| 1876 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 1877 | 3.7.14 Out-Going |
| 1878 | a) 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1879 | b) 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1880 | c) 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1881 | d) 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1882 | e) 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 1883 | f) 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 1884 | g) KWH digital meter fro lighting section |
| 1885 | h) Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 1886 | i) Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 1887 | j) Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 1888 | 3.7.15 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 1889 | 3.7.16 Supply and Laying of 3C X50Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03457b |
| 1890 | 3.7.17 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A By manual means |
| 1891 | 3.7.18 Filling in foundation trenches with sandas per drawing and technical specification Clause 305.3.9 MORD & 304 MORTHfor foundations of cc drains and pipe line trench RBR-FNDN-2(1) |
| 1892 | 3.7.19 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 1893 | 3.7.20 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etcM25 design mix concrete |
| 1894 | a) Column footings |
| 1895 | b) Columns |
| 1896 | c) Plinth beam |
| 1897 | 3.7.21 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 1898 | 3.7.22 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 1899 | 3.7.23 Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). BLD-CSTN-13-7 |
| 1900 | 3.7.24 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 1901 | 3.7.25 Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 1902 | 3.7.26 Supply and filling the transformer yard with 40mm HBG metal m/c |
| 1903 | BILL NO. 3.8 Supply, delivery, laying , jointing and testing of 350 mm dia D.I K9 Pumping mainfrom the proposed collection well cum Pump House near the the exisitng Water Works at sankili to the Junction point near Durga Temple. |
| 1904 | 3.8.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B by mechanical means |
| 1905 | 3.8.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A by manual means |
| 1906 | 3.8.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1II-A (Manual Means) - in hard rock |
| 1907 | 3.8.4 Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 1908 | 3.8.5 Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties- 350 DN K9 |
| 1909 | 3.8.6 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and includingtransportation. |
| 1910 | a) 250 DN P.N.1.60 (Sectionalisation) |
| 1911 | b) 200 DN P.N.1.60 (Scour) |
| 1912 | 3.8.7 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. - 100 DN P.N.1.00 |
| 1913 | 3.8.8 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1914 | 3.8.9 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spigot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) - 350mm dia |
| 1915 | 3.8.10 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 1916 | a) 350mm dia |
| 1917 | b) 200mm dia |
| 1918 | 3.8.11 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 - 350mm dia |
| 1919 | 3.8.12 Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 1920 | a) 250 mm DN Scour Valve |
| 1921 | b) 200 mm DN Sluice Valve |
| 1922 | 3.8.13 Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. - 100mm DN Air Valve |
| 1923 | 3.8.14 Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1924 | a) 350 mm dia |
| 1925 | b) 300 mm dia |
| 1926 | c) 200 mm dia |
| 1927 | d) 100 mm dia |
| 1928 | 3.8.15 Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 1929 | a) 250 DN P.N.1.60 ( Sectionalisation) |
| 1930 | b) 200 DN scour valve chambers |
| 1931 | c) 100 DN Air valve chambers |
| 1932 | 3.8.16 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 1933 | 3.8.17 Collection and spreading ofsand filling below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1934 | BILL NO. 3.9 Supply, delivery, laying , jointing and testing of 250 mm dia D.I K9 Pumping mainfrom the Junction point at Durga Templeto the existing 400 KL ELSR & proposed 500 KL ELSR at Municipal Office. |
| 1935 | 3.9.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B by mechanical means |
| 1936 | 3.9.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A by manual means |
| 1937 | 3.9.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1II-A (Manual Means) - In hard rock |
| 1938 | 3.9.4 Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 1939 | 3.9.5 Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties - 250 DN K9 |
| 1940 | 3.9.6 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and includingtransportation. |
| 1941 | a) 250 DN P.N.1.60 (Sectionalisation) |
| 1942 | b) 150 DN P.N.1.60 (Scour) |
| 1943 | 3.9.7 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1944 | 3.9.8 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spigot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) - 250mm dia |
| 1945 | 3.9.9 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 1946 | a) 250 mm dia |
| 1947 | b) 150mm dia |
| 1948 | 3.9.10 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 - 250mm dia |
| 1949 | 3.9.11 Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 1950 | a) 250 mm DN Sluice Valve |
| 1951 | b) 150 mm DN Sluice Valve |
| 1952 | 3.9.12 Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1953 | a) 250 mm dia |
| 1954 | b) 150 mm dia |
| 1955 | c) 80 mm dia |
| 1956 | 3.9.13 Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. |
| 1957 | a) 250 DN Sectional valve chambers |
| 1958 | b) 150 DN scour valve chambers |
| 1959 | 3.9.14 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 1960 | 3.9.15 Collection and spreading ofsand below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1961 | BILL NO. 3.10 Supply, delivery, laying , jointing and testing of 250 mm dia D.I K9 Pumping mainfrom the Junction point near Durga Temple to the Junction point at Gandhi Statue. |
| 1962 | 3.10.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B by mechanical means |
| 1963 | 3.10.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A by manual means |
| 1964 | 3.10.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1II-A (Manual Means) - in hard rock |
| 1965 | 3.10.4 Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 1966 | 3.10.5 Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties - 250 DN K9 |
| 1967 | 3.10.6 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and includingtransportation. |
| 1968 | a) 250 DN P.N.1.60 (Sectionalisation) |
| 1969 | b) 150 DN P.N.1.60 (Scour) |
| 1970 | 3.10.7 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. - 80 DN P.N.1.60 |
| 1971 | 3.10.8 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 1972 | 3.10.9 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spigot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994)- 250mm dia |
| 1973 | 3.10.10 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 1974 | a) 250 mm dia |
| 1975 | b) 150mm dia |
| 1976 | 3.10.11 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 - 250mm dia |
| 1977 | 3.10.12 Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 1978 | a) 250 mm DN Sluice Valve |
| 1979 | b) 150 mm DN Sluice Valve |
| 1980 | 3.10.13 Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. - 80 mm DN AirValve |
| 1981 | 3.10.14 Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 1982 | a) 250 mm dia |
| 1983 | b) 150 mm dia |
| 1984 | c) 80 mm dia |
| 1985 | 3.10.15 Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges |
| 1986 | a) 250 DN Sectional valve chambers |
| 1987 | b) 150 DN scour valve chambers |
| 1988 | c) 80 DN Air valve chambers |
| 1989 | 3.10.16 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 1990 | 3.10.17 Collection and spreading ofsand below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 1991 | BILL NO. 3.11 Supply, delivery, laying , jointing and testing of 150 mm dia D.I K9 Pumping mainfrom the Junction point at Gandhi Statueto the proposed 500 KL ELSR at Venkampeta. |
| 1992 | 3.11.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B by mechanical means |
| 1993 | 3.11.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A by manual means |
| 1994 | 3.11.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1II-A (Manual Means) - in hard rock |
| 1995 | 3.11.4 Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 1996 | 3.11.5 Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties - 150 DN K9 |
| 1997 | 3.11.6 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and includingtransportation. |
| 1998 | a) 150 DN P.N.1.60 (Sectionalisation) |
| 1999 | b) 100 DN P.N.1.60 (Scour) |
| 2000 | 3.11.7 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. - 80 DN P.N.1.60 |
| 2001 | 3.11.8 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 2002 | 3.11.9 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spigot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994)- 150mm dia |
| 2003 | 3.11.10 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 2004 | a) 150 mm dia |
| 2005 | b) 100mm dia |
| 2006 | 3.11.11 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 - 150mm dia |
| 2007 | 3.11.12 Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 2008 | a) 150 mm DN Sluice Valve |
| 2009 | b) 100 mm DN Sluice Valve |
| 2010 | 3.11.13 Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. - 80 mm DN AirValve |
| 2011 | 3.11.14 Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 2012 | a) 150 mm dia |
| 2013 | b) 100 mm dia |
| 2014 | c) 80 mm dia |
| 2015 | 3.11.15 Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges |
| 2016 | a) 150 DN Sectional valve chambers |
| 2017 | b) 150 DN scour valve chambers |
| 2018 | c) 80 DN Air valve chambers |
| 2019 | 3.11.16 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 2020 | 3.11.17 Collection and spreading ofsand below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 2021 | BILL NO. 3.12 Supply, delivery, laying , jointing and testing of 200 mm dia D.I K9 Pumping mainfrom the Junction point at Gandhi Statue to the Junction point near Vadama. |
| 2022 | 3.12.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B by mechanical means |
| 2023 | 3.12.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A by manual means |
| 2024 | 3.12.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1II-A (Manual Means) - in hard rock |
| 2025 | 3.12.4 Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 2026 | 3.12.5 Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties - 200 DN K9 |
| 2027 | 3.12.6 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and includingtransportation. |
| 2028 | a) 200 DN P.N.1.60 (Sectionalisation) |
| 2029 | 3.12.7 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. - 80 DN P.N.1.60 |
| 2030 | 3.12.8 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 2031 | 3.12.9 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spigot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994)- 200mm dia |
| 2032 | 3.12.10 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 2033 | a) 200 mm dia |
| 2034 | 3.12.11 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 - 200mm dia |
| 2035 | 3.12.12 Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 2036 | a) 200 mm DN Sluice Valve |
| 2037 | 3.12.13 Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. - 80 mm DN AirValve |
| 2038 | 3.12.14 Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 2039 | a) 200 mm dia |
| 2040 | 3.12.15 Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges |
| 2041 | a) 200 DN Sectional valve chambers |
| 2042 | b) 80 DN Air valve chambers |
| 2043 | 3.12.16 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 2044 | 3.12.17 Collection and spreading ofsand below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 2045 | BILL NO. 3.13 Supply, delivery, laying , jointing and testing of 150 mm dia D.I K9 Pumping mainfrom the Junction point near vadama to the proposed 500 KL ELSR at Vadama (R&B Bunglow) |
| 2046 | 3.13.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B by mechanical means |
| 2047 | 3.13.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A by manual means |
| 2048 | 3.13.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1II-A (Manual Means) - in hard rock |
| 2049 | 3.13.4 Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 2050 | 3.13.5 Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties - 150 DN K9 |
| 2051 | 3.13.6 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and includingtransportation. |
| 2052 | a) 150 DN P.N.1.60 (Sectionalisation) |
| 2053 | b) 100 DN P.N.1.60 (Scour) |
| 2054 | 3.13.7 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. - 80 DN P.N.1.60 |
| 2055 | 3.13.8 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 2056 | 3.13.9 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spigot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994)- 150mm dia |
| 2057 | 3.13.10 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 2058 | a) 150 mm dia |
| 2059 | b) 100mm dia |
| 2060 | 3.13.11 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 - 150mm dia |
| 2061 | 3.13.12 Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 2062 | a) 150 mm DN Sluice Valve |
| 2063 | b) 100 mm DN Sluice Valve |
| 2064 | 3.13.13 Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. - 80 mm DN AirValve |
| 2065 | 3.13.14 Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 2066 | a) 150 mm dia |
| 2067 | b) 100 mm dia |
| 2068 | c) 80 mm dia |
| 2069 | 3.13.15 Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges |
| 2070 | a) 150 DN Sectional valve chambers |
| 2071 | b) 150 DN scour valve chambers |
| 2072 | c) 80 DN Air valve chambers |
| 2073 | 3.13.16 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 2074 | 3.13.17 Collection and spreading ofsand below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 2075 | BILL NO. 3.14 Supply, delivery, laying , jointing and testing of 200 mm dia D.I K9 Pumping mainfrom the Junction point near vadama to the proposed 500 KL ELSR at NK Rajapuram. |
| 2076 | 3.14.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depthRBR-FNDN-1I-B by mechanical means |
| 2077 | 3.14.2 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A by manual means |
| 2078 | 3.14.3 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1II-A (Manual Means) - in hard rock |
| 2079 | 3.14.4 Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mmHBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete. |
| 2080 | 3.14.5 Supply and delivery of centrifugally cast (spun) DI pressure pipes (K9) S/S ends for potable water conforming to IS 8329-2000 in standard lengths of 6.00m each suitable for push on joint (rubber gasket D Jointing) with cement mortor lining inside the pipes with outside zinc coating and testing at facorty to the required pressure inculudingtransportation to site of work but excluding all taxes, & duties - 200 DN K9 |
| 2081 | 3.14.6 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and includingtransportation. |
| 2082 | a) 200 DN P.N.1.60 (Sectionalisation) |
| 2083 | b) 150 DN P.N.1.60 (Scour) |
| 2084 | 3.14.7 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. - 80 DN P.N.1.60 |
| 2085 | 3.14.8 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN16 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 2086 | 3.14.9 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with socket / Spigot endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994)- 200mm dia |
| 2087 | 3.14.10 Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with flanged endscarefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 2088 | a) 200 mm dia |
| 2089 | b) 150mm dia |
| 2090 | 3.14.11 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), including the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987 - 200mm dia |
| 2091 | 3.14.12 Labour charges for lowering and keeping in position of C.I. D/F sluice valves etc., complete. |
| 2092 | a) 200 mm DN Sluice Valve |
| 2093 | b) 150 mm DN Scour Valve |
| 2094 | 3.14.13 Labour charges for fixing kinetic air valves with isolating sluice valves, double air valves/ air cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. - 80 mm DN AirValve |
| 2095 | 3.14.14 Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 2096 | a) 200 mm dia |
| 2097 | b) 150 mm dia |
| 2098 | c) 80 mm dia |
| 2099 | 3.14.15 Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges |
| 2100 | a) 200 DN Sectional valve chambers |
| 2101 | b) 200 DN scour valve chambers |
| 2102 | c) 80 DN Air valve chambers |
| 2103 | 3.14.16 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 2104 | 3.14.17 Collection and spreading ofsand below the pipeline including and conveyance of materials to site with all leads, liftsto work site all labour charges and stacking to departmentalguage including watering, tamping, ramming, labour charges, all other incidental and operational charges etccost and conveyance of all materialsetc., complete as per and as directed by the departmental officer incharge of work.(for road crossings) |
| 2105 | BILL NO. 3.15 Design and Construction of 500 KL capacityELSR at Venkampeta with a stagging of 15 mts including Inlet , Outlet , Overflow, scour connections and dog legged stair case and all other connections etc complete. |
| 2106 | 3.15.1 Construction of 500 KL capacity RCC ELSR with 15.00 m staging |
| 2107 | Construction of 4 No 500 KL RCC ELSR of suitable design in single compartment at Venkampeta with Single row of columns,centrall dome /Flat slab,the inner columns containing upto roofslab with a staging of 14.00m and with dead storage of 0.15m and 0.3. 1. Average G.L : + 121.770,2. L.W.L : + 135.770,3.M.W.L : + 139.770, The minimum thickness for the roof slab shall be 100mm. The minimum thickness of bottom slab/dome shall be 200mm ( with reinforcement on both faces) and uncracked section shall be adopted. All RCC shall be M30 grade, PCC basement course shall be in (1:3:6 )and roof level. Braces and ring beams shall beof uniform cross section.Rate inclusive ofthree coats of epoxy paint Food Grade of Best quality to inner surface of the reservoir including roof .For construction of ELSR for a finished work including 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, pipes, bends, valves etc., for pipe connections but excluding cost of pipes, bends and valves as per departmental designs and drawings.Wind pressures upto 350 kg / sq m. For every 100 Kg/Sqm decreased in wind pressure, the rate is to be decreased by 5%. For tribal/Agency / Rural area, the above rates shall be increased by 10% . If the ELSR is to be designed for seismic forces (a) the above rates are applied upto Zone-II earth quake. For Zone-III earth quake the above rates are to be increased by 33 1/3%.Fixtures include :The basic rate is inclusive of following Fixtures-i) Pipe connections & Specials with D.I materials,a) All pipe conections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DImaterial.b) The Valves for above pipe connections also shall be of DI material of PN,c) All specials such as Bends,Tees, Reducers, Duckfoot Bends,Bell mouths etc,. shall be of DI material. |
| 2108 | II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs - Inlet Pipe - 300mm dia,Out let Pipe - 350mm dia,Over Flow pipe - 350m dia,Scour Pipe - 200mm dia, b) For 800 KL to 1500 Kl ELSRs - Inlet Pipe - 400mm dia, Out let Pipe - 450mm dia,Over Flow pipe - 450m dia,Scour Pipe - 200mm dia, c) For above 1500 KL to 2500 Kl ELSRs, Inlet Pipe - 400mm dia.,Out let Pipe - 500mm dia, Over Flow pipe - 500m dia, Scour Pipe - 200mm dia, iii) Manhole Frames & Covers, a) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min.of 150mm dia) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos., v) RCC Finial ventilatorwith fly/birdprotection with GI mesh- 1 No., vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 No, viii)The staircase shall be enclosed with brick masonary walls on three side and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry., x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia pipe & middle railing of 25mm dia and verticals with 40mm dia at an interval not more than of 1.00m c/c, xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No), xii) Lightening Arrestor with all its accessories complete including earthing,with relevant IS Codes- 1 No. . |
| 2109 | r) Compound Wall:- Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall be minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM(1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8)prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Gound level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angulars of 25mm X 25mm X 4mm in \"Y\" shape to hieght of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauge shall be streched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4) prop on both sides of brick work. Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreased. |
| 2110 | Note:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KLshall be as follows.: ii) 1000 KL : 0.047%, iii) 1500 KL : 0.034%,For intermediate capacities, interpolated percentagesshall be adopted.1200KL ELSR -0.034+((1500-1200)/(1500-1000))*(0.047-0.034)= 0.0418%, s) Watchmen Quarter:Staff Quarter shall be constructed for a minimum plinth area of 40 sqm with the following specification: RCC framed structure withconcrete grade not less than M20 design mix at the locations specified by the department at the time of execution with verandah, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases. MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides openable shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall provided. Septic tank for 5 users shall be provided. |
| 2111 | BILL NO. 3.16 Design and Construction of 500 KL capacityELSR at Municipal office with a stagging of 15 mts including Inlet , Outlet , Overflow, scour connections and dog legged stair case and all other connections etc complete. |
| 2112 | 3.16.1 Construction of 500 KL capacity RCC ELSR with 15.00 m staging |
| 2113 | Construction of 4 No 500 KL RCC ELSR of suitable design in single compartment at Venkampeta with Single row of columns,centrall dome /Flat slab,the inner columns containing upto roofslab with a staging of 14.00m and with dead storage of 0.15m and 0.3. 1. Average G.L : + 121.770,2. L.W.L : + 135.770,3.M.W.L : + 139.770, The minimum thickness for the roof slab shall be 100mm. The minimum thickness of bottom slab/dome shall be 200mm ( with reinforcement on both faces) and uncracked section shall be adopted. All RCC shall be M30 grade, PCC basement course shall be in (1:3:6 )and roof level. Braces and ring beams shall beof uniform cross section.Rate inclusive ofthree coats of epoxy paint Food Grade of Best quality to inner surface of the reservoir including roof .For construction of ELSR for a finished work including 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, pipes, bends, valves etc., for pipe connections but excluding cost of pipes, bends and valves as per departmental designs and drawings.Wind pressures upto 350 kg / sq m. For every 100 Kg/Sqm decreased in wind pressure, the rate is to be decreased by 5%. For tribal/Agency / Rural area, the above rates shall be increased by 10% . If the ELSR is to be designed for seismic forces (a) the above rates are applied upto Zone-II earth quake. For Zone-III earth quake the above rates are to be increased by 33 1/3%.Fixtures include :The basic rate is inclusive of following Fixtures-i) Pipe connections & Specials with D.I materials,a) All pipe conections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DImaterial.b) The Valves for above pipe connections also shall be of DI material of PN,c) All specials such as Bends,Tees, Reducers, Duckfoot Bends,Bell mouths etc,. shall be of DI material. |
| 2114 | II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs - Inlet Pipe - 300mm dia,Out let Pipe - 350mm dia,Over Flow pipe - 350m dia,Scour Pipe - 200mm dia, b) For 800 KL to 1500 Kl ELSRs - Inlet Pipe - 400mm dia, Out let Pipe - 450mm dia,Over Flow pipe - 450m dia,Scour Pipe - 200mm dia, c) For above 1500 KL to 2500 Kl ELSRs, Inlet Pipe - 400mm dia.,Out let Pipe - 500mm dia, Over Flow pipe - 500m dia, Scour Pipe - 200mm dia, iii) Manhole Frames & Covers, a) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min.of 150mm dia) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos., v) RCC Finial ventilatorwith fly/birdprotection with GI mesh- 1 No., vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 No, viii)The staircase shall be enclosed with brick masonary walls on three side and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry., x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia pipe & middle railing of 25mm dia and verticals with 40mm dia at an interval not more than of 1.00m c/c, xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No), xii) Lightening Arrestor with all its accessories complete including earthing,with relevant IS Codes- 1 No. . |
| 2115 | r) Compound Wall:- Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall be minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM(1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8)prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Gound level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angulars of 25mm X 25mm X 4mm in \"Y\" shape to hieght of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauge shall be streched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4) prop on both sides of brick work. Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreased. |
| 2116 | Note:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KLshall be as follows.: ii) 1000 KL : 0.047%, iii) 1500 KL : 0.034%,For intermediate capacities, interpolated percentagesshall be adopted.1200KL ELSR -0.034+((1500-1200)/(1500-1000))*(0.047-0.034)= 0.0418%, s) Watchmen Quarter:Staff Quarter shall be constructed for a minimum plinth area of 40 sqm with the following specification: RCC framed structure withconcrete grade not less than M20 design mix at the locations specified by the department at the time of execution with verandah, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases. MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides openable shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall provided. Septic tank for 5 users shall be provided. |
| 2117 | BILL NO. 3.17 Design and Construction of 500 KL capacityELSR at NK rajapuram with a stagging of 15 mts including Inlet , Outlet , Overflow, scour connections and dog legged stair case and all other connections etc complete |
| 2118 | 3.17.1 Construction of 500 KL capacity RCC ELSR with 15.00 m staging |
| 2119 | Construction of 4 No 500 KL RCC ELSR of suitable design in single compartment at Venkampeta with Single row of columns,centrall dome /Flat slab,the inner columns containing upto roofslab with a staging of 14.00m and with dead storage of 0.15m and 0.3. 1. Average G.L : + 121.770,2. L.W.L : + 135.770,3.M.W.L : + 139.770, The minimum thickness for the roof slab shall be 100mm. The minimum thickness of bottom slab/dome shall be 200mm ( with reinforcement on both faces) and uncracked section shall be adopted. All RCC shall be M30 grade, PCC basement course shall be in (1:3:6 )and roof level. Braces and ring beams shall beof uniform cross section.Rate inclusive ofthree coats of epoxy paint Food Grade of Best quality to inner surface of the reservoir including roof .For construction of ELSR for a finished work including 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, pipes, bends, valves etc., for pipe connections but excluding cost of pipes, bends and valves as per departmental designs and drawings.Wind pressures upto 350 kg / sq m. For every 100 Kg/Sqm decreased in wind pressure, the rate is to be decreased by 5%. For tribal/Agency / Rural area, the above rates shall be increased by 10% . If the ELSR is to be designed for seismic forces (a) the above rates are applied upto Zone-II earth quake. For Zone-III earth quake the above rates are to be increased by 33 1/3%.Fixtures include :The basic rate is inclusive of following Fixtures-i) Pipe connections & Specials with D.I materials,a) All pipe conections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DImaterial.b) The Valves for above pipe connections also shall be of DI material of PN,c) All specials such as Bends,Tees, Reducers, Duckfoot Bends,Bell mouths etc,. shall be of DI material. |
| 2120 | II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs - Inlet Pipe - 300mm dia,Out let Pipe - 350mm dia,Over Flow pipe - 350m dia,Scour Pipe - 200mm dia, b) For 800 KL to 1500 Kl ELSRs - Inlet Pipe - 400mm dia, Out let Pipe - 450mm dia,Over Flow pipe - 450m dia,Scour Pipe - 200mm dia, c) For above 1500 KL to 2500 Kl ELSRs, Inlet Pipe - 400mm dia.,Out let Pipe - 500mm dia, Over Flow pipe - 500m dia, Scour Pipe - 200mm dia, iii) Manhole Frames & Covers, a) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min.of 150mm dia) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos., v) RCC Finial ventilatorwith fly/birdprotection with GI mesh- 1 No., vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 No, viii)The staircase shall be enclosed with brick masonary walls on three side and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry., x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia pipe & middle railing of 25mm dia and verticals with 40mm dia at an interval not more than of 1.00m c/c, xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No), xii) Lightening Arrestor with all its accessories complete including earthing,with relevant IS Codes- 1 No. . |
| 2121 | r) Compound Wall:- Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall be minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM(1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8)prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Gound level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angulars of 25mm X 25mm X 4mm in \"Y\" shape to hieght of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauge shall be streched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4) prop on both sides of brick work. Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreased. |
| 2122 | Note:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KLshall be as follows.: ii) 1000 KL : 0.047%, iii) 1500 KL : 0.034%,For intermediate capacities, interpolated percentagesshall be adopted.1200KL ELSR -0.034+((1500-1200)/(1500-1000))*(0.047-0.034)= 0.0418%, s) Watchmen Quarter:Staff Quarter shall be constructed for a minimum plinth area of 40 sqm with the following specification: RCC framed structure withconcrete grade not less than M20 design mix at the locations specified by the department at the time of execution with verandah, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases. MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides openable shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall provided. Septic tank for 5 users shall be provided. |
| 2123 | BILL NO. 3.18 Design and Construction of 500 KL capacityELSR at Vadama( R & B) with a stagging of 15 mts including Inlet , Outlet , Overflow, scour connections and dog legged stair case and all other connections etc complete. |
| 2124 | 3.18.1 Construction of 500 KL capacity RCC ELSR with 15.00 m staging |
| 2125 | Construction of 4 No 500 KL RCC ELSR of suitable design in single compartment at Venkampeta with Single row of columns,centrall dome /Flat slab,the inner columns containing upto roofslab with a staging of 14.00m and with dead storage of 0.15m and 0.3. 1. Average G.L : + 121.770,2. L.W.L : + 135.770,3.M.W.L : + 139.770, The minimum thickness for the roof slab shall be 100mm. The minimum thickness of bottom slab/dome shall be 200mm ( with reinforcement on both faces) and uncracked section shall be adopted. All RCC shall be M30 grade, PCC basement course shall be in (1:3:6 )and roof level. Braces and ring beams shall beof uniform cross section.Rate inclusive ofthree coats of epoxy paint Food Grade of Best quality to inner surface of the reservoir including roof .For construction of ELSR for a finished work including 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, pipes, bends, valves etc., for pipe connections but excluding cost of pipes, bends and valves as per departmental designs and drawings.Wind pressures upto 350 kg / sq m. For every 100 Kg/Sqm decreased in wind pressure, the rate is to be decreased by 5%. For tribal/Agency / Rural area, the above rates shall be increased by 10% . If the ELSR is to be designed for seismic forces (a) the above rates are applied upto Zone-II earth quake. For Zone-III earth quake the above rates are to be increased by 33 1/3%.Fixtures include :The basic rate is inclusive of following Fixtures-i) Pipe connections & Specials with D.I materials,a) All pipe conections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DImaterial.b) The Valves for above pipe connections also shall be of DI material of PN,c) All specials such as Bends,Tees, Reducers, Duckfoot Bends,Bell mouths etc,. shall be of DI material. |
| 2126 | II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs - Inlet Pipe - 300mm dia,Out let Pipe - 350mm dia,Over Flow pipe - 350m dia,Scour Pipe - 200mm dia, b) For 800 KL to 1500 Kl ELSRs - Inlet Pipe - 400mm dia, Out let Pipe - 450mm dia,Over Flow pipe - 450m dia,Scour Pipe - 200mm dia, c) For above 1500 KL to 2500 Kl ELSRs, Inlet Pipe - 400mm dia.,Out let Pipe - 500mm dia, Over Flow pipe - 500m dia, Scour Pipe - 200mm dia, iii) Manhole Frames & Covers, a) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min.of 150mm dia) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos., v) RCC Finial ventilatorwith fly/birdprotection with GI mesh- 1 No., vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 No, viii)The staircase shall be enclosed with brick masonary walls on three side and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry., x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia pipe & middle railing of 25mm dia and verticals with 40mm dia at an interval not more than of 1.00m c/c, xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No), xii) Lightening Arrestor with all its accessories complete including earthing,with relevant IS Codes- 1 No. . |
| 2127 | r) Compound Wall:- Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall be minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM(1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8)prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Gound level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angulars of 25mm X 25mm X 4mm in \"Y\" shape to hieght of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauge shall be streched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4) prop on both sides of brick work. Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreased. |
| 2128 | Note:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KLshall be as follows.: ii) 1000 KL : 0.047%, iii) 1500 KL : 0.034%,For intermediate capacities, interpolated percentagesshall be adopted.1200KL ELSR -0.034+((1500-1200)/(1500-1000))*(0.047-0.034)= 0.0418%, s) Watchmen Quarter:Staff Quarter shall be constructed for a minimum plinth area of 40 sqm with the following specification: RCC framed structure withconcrete grade not less than M20 design mix at the locations specified by the department at the time of execution with verandah, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases. MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides openable shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall provided. Septic tank for 5 users shall be provided. |
| 2129 | BILL NO. 3.19 Construction of Watchman quarters at Head water works |
| 2130 | 3.19.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A |
| 2131 | 3.19.2 Filling in foundation trenches with sandas per drawing and technical specification Clause 305.3.9 MORD & 304 MORTHfor foundations of cc drains and pipe line trench RBR-FNDN-2(1) |
| 2132 | 3.19.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 2133 | 3.19.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 2134 | a) Column footings |
| 2135 | b) Columns |
| 2136 | c) Plinth Beam |
| 2137 | d) Lintle beams ,Windows |
| 2138 | e) Roof Beams |
| 2139 | f) Roof slab0.125m thick with 0.30m extension all sides |
| 2140 | g)Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free endWindows |
| 2141 | h) Loft slab 0.075m thick kitchen |
| 2142 | 3.19.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 2143 | a) Ground Floor |
| 2144 | b) 1st Floor |
| 2145 | 3.19.6 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 2146 | a) Ground Floor |
| 2147 | b) 1st Floor |
| 2148 | 3.19.7 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height - for ceiling slab area |
| 2149 | 3.19.8 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 2150 | a) Inside |
| 2151 | b) Outside |
| 2152 | 3.19.9 Supply delivery and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss - 50mm Thick |
| 2153 | 3.19.10 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 2154 | a) Door -D - 1.20X2.10 m |
| 2155 | b) doorsD1 -1.0X2.10m |
| 2156 | 3.19.11 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 2157 | a) windows 1.20x1.20 |
| 2158 | 3.19.12 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 2159 | a) Toilet door D2 |
| 2160 | 3.19.13 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 2161 | a) Toilet door D2 |
| 2162 | 3.19.14 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 2163 | 3.19.15 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 2164 | 3.19.16 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete - Windows |
| 2165 | 3.19.17 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per sss - Windows Grill |
| 2166 | 3.19.18 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 2167 | 3.19.19 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour charge |
| 2168 | 3.19.20 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges |
| 2169 | 3.19.21 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 2170 | 3.19.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 2171 | 3.19.23 supply andrun of 2 of36/0.3 mm. (2.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 2172 | 3.19.24 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 2173 | 3.19.25 supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 2174 | 3.19.26 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete. |
| 2175 | 3.19.27 Supply and fixing SPN Distribution board with IP-30 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete |
| 2176 | 3.19.28 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 2177 | 3.19.29 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 2178 | 3.19.30 Supply of 1 x 36/40W Box type tube light luminaire powder coated CRCA sheet steel housing with Electronic Ballast Chokes and all standard accessoriesof makes Wipro / G.E. / Phillips / Crompton / Bajaj. |
| 2179 | 3.19.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 2180 | 3.19.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 2181 | 3.19.33 Supplying & Fixing low down porcelain flushing tank 10 Lit Capacity Hindustan Sanitary ware/ parry/ Neycer with internal components |
| 2182 | 3.19.34 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 2183 | 3.19.35 Supply of 110 mm dia 3 M single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 2184 | 3.19.36 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 2185 | 3.19.37 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 2186 | 3.19.38 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 2187 | 3.19.39 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 2188 | 3.19.40 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 2189 | a) 25 mm dia nominal bore -from tank to jn forof individual lines |
| 2190 | b) 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 2191 | c) 15 mm dia nominal bore -for internal |
| 2192 | 3.19.41 S&F of GI &GM fittings |
| 2193 | a) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 2194 | b) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 2195 | c) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 2196 | d)S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 2197 | e) S& F GI union Ist Quality |
| 2198 | i) 12.70mm |
| 2199 | ii) 19.05mm |
| 2200 | iii) 25.40mm |
| 2201 | 3.19.42 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD.Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth |
| 2202 | 3.19.43 Filling with sandin foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 2203 | 3.19.44 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 2204 | 3.19.45 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 2205 | 3.19.46 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 2206 | 3.19.47 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs - For septic Tank 0.15 m thick |
| 2207 | 3.19.48 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 2208 | BILL NO. 3.20 Construction ofSCADA Room 8.00 x 12.00 Size. |
| 2209 | 3.20.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH |
| 2210 | a) Mechanical means |
| 2211 | b) Manual means |
| 2212 | 3.20.2 Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work (APDSS No.101). |
| 2213 | 3.20.3 Laying plain Cement concrete (1:4:8)using 40mm nominal size HBG metal M/C including cost and conveyance of all materials from approved quarry, machine mixing, vibrating, laying, levelling, ramming, curing and labour charges etc., complete. As per APSS 402 (BLD-CSTN-2-5). |
| 2214 | 3.20.4 Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work. |
| 2215 | 3.20.5 Vibrated Reinforced Cement concrete (M 25) Nominal Mix using 20mm metal using concrete mixer including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, centering, shuttering etc.,complete for Bed.- for Septic tanks |
| 2216 | 3.20.6 Vibrated Reinforced Cement concrete (M 25) Nominal Mix using 20mm metal using concrete mixer including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, centering, shuttering etc.,complete - for Septic tank |
| 2217 | 3.20.7 Supply and placing of the RCC M - 25 Design Mix Concrete corresponding to IS 456 using MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including pumping, centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. |
| 2218 | a) Footings |
| 2219 | b) Pedastals around Columns |
| 2220 | c) Columns Up to plinth |
| 2221 | d) Plinth Beams 300 x 400 |
| 2222 | e) Columns |
| 2223 | i) Up to Ground Floor Roof Level |
| 2224 | ii) Up to First Floor Roof Level |
| 2225 | f) Beams 230 x 500 |
| 2226 | g) Lintels |
| 2227 | h) Sunshades |
| 2228 | i) Staircase slab 0.15 m thick |
| 2229 | j) RCC Slab 150mm thick |
| 2230 | 3.20.8 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) for pre cast slabs of culverts- RBR-FNDN-8 & Revised Data sl.No-5 |
| 2231 | 3.20.9 Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work (BLD-CSTN-3-1). |
| 2232 | a) For Ground Floor |
| 2233 | b) For First Floor |
| 2234 | 3.20.10 11.5 cm wide Brick masonry for super-structure on ground floor in cm (1:3) using second class traditional size bricks including cost of all materials, seigniorage charges, labour and all operations for constructing half brick masonry, mixing cement mortar, curing etc., complete for finished item of work, but excluding conveyance charges of materials. |
| 2235 | 3.20.11 Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. - Outside |
| 2236 | a) For Ground Floor |
| 2237 | b) For First Floor |
| 2238 | 3.20.12 Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. - Inside |
| 2239 | 3.20.13 Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. - Ceiling |
| 2240 | 3.20.14 Flooring with 50 mm thick Rough Cuddapah/Shabad stones, set over base coat of cement mortar (1 : 8) 12 mm thick over CC bed already laid or RCC roof slab, including pointing with cement mortar 1:3 duly filling joints nearly, including cost of all materials like flooring stone, cement, sand, and water etc., complete, including seigniorage charges,labour charges for dressing of flooring stones etc., complete for finished item of work, but excluding the cost of conveyance of all materials. |
| 2241 | 3.20.15 Flooring with ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials.BLD-CSTN-7-6 - For Toilets |
| 2242 | 3.20.16 Dadooing to walls with first quality glazed coloured tiles approved colour of any size set over base coat of C.M(1:3)prop. 12mm thick and neat grey cement slurry of honey like consistency spread at the rate of 3.3Kg of cement per sqm and jointed with neat white cement paste at 0.20 kg per sqm mixed with pigment of matching shade to match the shade of tiles including cost and conveyance of all materials labour charges, water to work site,seignourage and all operational .incidental , mixing mortar , fixing inposition ,lift charges, curing etc., complete as per SS or as directed by the departmental authorities for finished item of work. - For Toilets |
| 2243 | 3.20.17 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) outside |
| 2244 | 3.20.18 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) Inside |
| 2245 | 3.20.19 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) Inside - for Ceiling |
| 2246 | 3.20.20 Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) pure polyester powder upto 50-60 microns thick, outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the equired rigidity and effective acoustic insulation with 6” Tower bolt – 1 No., 6” D handles – 2 Nos., 10” Aldrop – 1 No., Butt Hinges – 3 Nos, Mortise Lock of approved quality – 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws complete for finished item of work for Single leaf Door |
| 2247 | 3.20.21 Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6\" pitch complete for finished item of work. |
| 2248 | 3.20.22 Providing & fixing 30 mm thick solid panel PVC door shutter consisting of frame made out of 19 guage M.S tube of 19 x 19 mm for stiles, top & bottom rail, with a coat of primer of approved make. M.S. Frame covered with 5 mm thick heat moulded PVC “C” channel of size of 30 x 50 mm forming stiles, 5 mm thick 75 mm wide PVC sheet for top, lock & bottom rail on either side 20 mm wide cross PVC sheet as gap insert for top & bottom rail, panelling of 10mm(+/-)( 5mm+5mm)” thick PVC sheet fitted in the M.S. frame welded /sealed to the stiles, on either side joined together with solvent cement adhesive etc., additional 5 mm thick PVC strip of 20 mm width stuck on the interior side of the C channel using solvent cement, complete as per direction of Engineer–in–charge, manufacturers specification. ( BMT-N.51). |
| 2249 | 3.20.23 Supplying and fixing of Top Hung Ventilators made of pre - painted steel(base steel as per IS 513 of -0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 micronsthick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x52 mm section and for shutter of 46 x 46mm section for mullion 46 x 70 mm,The Ventilator to be panelled 4 mmpinhead glass with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joinedwith corner brocket mullions fixed usingmullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate,Mullion caps made of glass filled nylon,frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with6\" pitch complete for finished item of work.Ventilators: Top Hung 2 \"-0\" x 2\"-0\" (609.6x609.6mm) outer frame section size of 46mm x 52 mm shutter frame section size of 46mm x 46 mm |
| 2250 | 3.20.24 Providing and fixing Thermocole False ceiling in true horizontal level 600 mm x 600 mm using 15 mm/ 19 mmthick Thermocole sheet anodised Aluminium Tee sections of size 24.50 mm x 24.0 mm x 2.4 mm in grid with cross tee of size 24 x 24.5 mm at every 600 mm c/c and anodised aluminium wall angle of size 24 x 24 mm fixed to periphery of the wall and the above grid is suspended at every 1200 mm c/c in both directions using 2.0 mm thick GI Wire for finished of size 600 x 600 mm including Cost &conveyance of all materials and labour charges such as cutting , fixing of standing of frame work exposing roof making complete for finished item of work |
| 2251 | 3.20.25 Providing Electrification |
| 2252 | a) Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 2253 | b) Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 2254 | c) Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complete for light, bell , fan and exhaust fan points in non - residential building |
| 2255 | d) supply andrun of 2 of36/0.3 mm. (2.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 2256 | e) supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 2257 | f) supply andrun of 4 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., - for Service Wire |
| 2258 | g) Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 2259 | h) Supply and fixing TPN Distribution board with IP-30 protection suitable for 3 phase ELCB / RCCB / FP Isolator as incomer and 10kA SP MCBs as outing going including internal connection and labour charges for surface / flush mounting etc., complete.BLD-ELEC-4.4.3 |
| 2260 | i) Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 2261 | j) Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 2262 | k) Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs. |
| 2263 | l) Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 2264 | m) Labour charges Fixing of 40W tube light luminaire on wall / Ceiling with/ TW round blocks with all accessories including giving connections and all labour charges etc., complete. |
| 2265 | n) Supply and fixing of 16A 3/2 pin flush type wall plug modular socket with shutter and 16A modular switche controll on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete. Makes of Switches : GM G Home /Anchor Penta Cherry / Gold Madel Olive / Million Zoom / Great White |
| 2266 | 3.20.26 Supply of 2.0 TR 5 Star capable of delivering not less than 21600 BTU/hr and above with operating onrefrigerant R-410A / R-32. Makes: As per list of recommended brands ascategory II INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz,1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser. |
| 2267 | 3.20.27 Water Supply and Sanitary Arrangements |
| 2268 | a) Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks - 200 Litres Capaciy |
| 2269 | b) Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of work - For Toilets |
| 2270 | c) Supplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 30mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work - For Toilets |
| 2271 | d) Supplying and fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit complete for finished item of work for all floors |
| 2272 | e) Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 2273 | f) Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 2274 | g) Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 2275 | h) Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - 110mm dia |
| 2276 | i) Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 2277 | j) S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 2278 | i) 25 mm dia nominal bore -from tank to jn forof individual lines and inlet |
| 2279 | ii) 20 mm dia nominal bore -fromjn forof individual lines to toilets |
| 2280 | iii) 15 mm dia nominal bore -for internal |
| 2281 | k) S&F of GI & GM fittings |
| 2282 | i) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 2283 | ii) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 2284 | iii) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 2285 | l) S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 2286 | m) S& F GI union Ist Quality |
| 2287 | i) 12.70mm |
| 2288 | ii) 19.05mm |
| 2289 | iii) 25.40mm |
| 2290 | Bill No: 3.21 Providing Instrumantation, Automation and SCADA for 500KL ELSR at Municipal office automation and 24 x Watersupply in Palakonda Nagar Panchayat under APUWSSMIP-AIIB |
| 2291 | 3.21.1 Instrumantation and Automation of the Pumping System: |
| 2292 | a) Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer - For Raw Water Pumping Station as per the above specification |
| 2293 | b) Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. - For Raw Water Pumping Station as per the above specification |
| 2294 | c) Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer - DN 150 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification |
| 2295 | d) Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. - 350MM Dia Above Specification. - outlet of Raw Water Pumping Station at Nagavalli river |
| 2296 | e) Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. - Raw Water Inlet of Water Treatment plant |
| 2297 | f) Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. - Raw Water Inlet of Water Treatment plant |
| 2298 | g) Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. - Raw Water Inlet of Water Treatment plant |
| 2299 | h) Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. - Raw Water Inlet of Water Treatment plant |
| 2300 | i) Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.- Raw Water inlet and clear water outlet at WTP |
| 2301 | j) Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. - For Raw Water Pumping Station as per the above specification |
| 2302 | Logic for RTU opeartaions:1. RTU panel for local operaion of the pumps in manual and Auto Mode.2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables.3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves.5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned.6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves.7. In manual opeartion, all the equiment can be run through PLC panel by individual operations.8.The RTU connected with SCADA for remote monitoring and operation.9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge. |
| 2303 | 3.21.2Reservoir Inlet Management |
| 2304 | a) supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 2305 | i) 100MM Dia Above Specification- Inlet of 400 KL Existing ELSR at Municipal office |
| 2306 | ii)150 MM Dia Above Specification. |
| 2307 | b) Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 2308 | i) 100MM Dia Above Specification- Inlet of 400 KL Existing ELSR at Municipal office |
| 2309 | ii)150 MM Dia Above Specification. |
| 2310 | c) Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 2311 | i) 100MM Dia Above Specification- Inlet of 400 KL Existing ELSR at Municipal office |
| 2312 | ii)150 MM Dia Above Specification. |
| 2313 | d) Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2314 | i) 100MM Dia Above Specification- Inlet of 400 KL Existing ELSR at Municipal office |
| 2315 | ii)150 MM Dia Above Specification. |
| 2316 | e) Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2317 | Inlet of 400 KL Existing ELSR at Municipal office |
| 2318 | Inlet of 500 KL Proposed ELSR at Municipal office |
| 2319 | Inlet of 500 KL Proposed ELSR at Venkaipeta |
| 2320 | Inlet of 500 KL Proposed ELSR at Vadama |
| 2321 | Inlet of 500 KL Proposed ELSR at Rajapuram |
| 2322 | f) Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 2323 | Inlet of 400 KL Existing ELSR at Municipal office |
| 2324 | Inlet of 500 KL Proposed ELSR at Municipal office |
| 2325 | Inlet of 500 KL Proposed ELSR at Venkaipeta |
| 2326 | Inlet of 500 KL Proposed ELSR at Vadama |
| 2327 | Inlet of 500 KL Proposed ELSR at Rajapuram |
| 2328 | g) Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 2329 | Inlet of 400 KL Existing ELSR at Municipal office |
| 2330 | Inlet of 500 KL Proposed ELSR at Municipal office |
| 2331 | Inlet of 500 KL Proposed ELSR at Venkaipeta |
| 2332 | Inlet of 500 KL Proposed ELSR at Vadama |
| 2333 | Inlet of 500 KL Proposed ELSR at Rajapuram |
| 2334 | h) Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 2335 | Inlet of 400 KL Existing ELSR at Municipal office |
| 2336 | Inlet of 500 KL Proposed ELSR at Municipal office |
| 2337 | Inlet of 500 KL Proposed ELSR at Venkaipeta |
| 2338 | Inlet of 500 KL Proposed ELSR at Vadama |
| 2339 | Inlet of 500 KL Proposed ELSR at Rajapuram |
| 2340 | i) Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2341 | Inlet of 400 KL Existing ELSR at Municipal office |
| 2342 | Inlet of 500 KL Proposed ELSR at Municipal office |
| 2343 | Inlet of 500 KL Proposed ELSR at Venkaipeta |
| 2344 | Inlet of 500 KL Proposed ELSR at Vadama |
| 2345 | Inlet of 500 KL Proposed ELSR at Rajapuram |
| 2346 | j) Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 2347 | Inlet of 400 KL Existing ELSR at Municipal office |
| 2348 | Inlet of 500 KL Proposed ELSR at Municipal office |
| 2349 | Inlet of 500 KL Proposed ELSR at Venkaipeta |
| 2350 | Inlet of 500 KL Proposed ELSR at Vadama |
| 2351 | Inlet of 500 KL Proposed ELSR at Rajapuram |
| 2352 | k) Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2353 | l) Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2354 | m) Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2355 | n) Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2356 | 3.31.3 24 x 7 Water Supply ::DMA Management :: |
| 2357 | a) supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 2358 | i) 200MM Dia Above Specification - Inlet of DMA-1 under 500 KL ELSR at At Municipal office |
| 2359 | ii) 250MM Dia Above Specification - Inlet of DMA-2 under 500 KL ELSR at At Municipal office |
| 2360 | b) Supply and deliveryof Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 2361 | i) 200MM Dia Above Specification - Inlet of DMA-1 under 500 KL ELSR at At Municipal office |
| 2362 | ii) 250MM Dia Above Specification - Inlet of DMA-2 under 500 KL ELSR at At Municipal office |
| 2363 | c) Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 2364 | i) 200MM Dia Above Specification - Inlet of DMA-1 under 500 KL ELSR at At Municipal office |
| 2365 | ii) 250MM Dia Above Specification - Inlet of DMA-2 under 500 KL ELSR at At Municipal office |
| 2366 | d) Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2367 | i) 200MM Dia Above Specification - Inlet of DMA-1 under 500 KL ELSR at At Municipal office |
| 2368 | ii) 250MM Dia Above Specification - Inlet of DMA-2 under 500 KL ELSR at At Municipal office |
| 2369 | e) Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer - Inlet of DMA-1&2 under 500 KL ELSR at At Municipal office |
| 2370 | f) Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.- Inlet of DMA-1&2 under 500 KL ELSR at At Municipal office |
| 2371 | g) Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. - Inlet of DMA-1&2 under 500 KL ELSR at At Municipal office |
| 2372 | h) Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2373 | i) Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2374 | j) Providing, Installing and satisfactory field testing of Self Powered Presuure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 2375 | k) Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 2376 | 3.21.4 Local SCADA Control Sation: |
| 2377 | 3.21.4.1 Establishment of HARDWARE for Individual Local Control Station at Individual ULB :: |
| 2378 | a) Supply,erection, testing, commissioning of Hard ware for the SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter managementwhere the instrumantation and automation developed under this project and synchornization by deploying the followingcomponents including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. i) Desktop PC Station with specification of I7Processor, 8 GB Ram, ,512 GB SSD,Licensed OS, 21\" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL - 1.00Job, ii) 55\" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screenswith required cables and connectors etc., complete - 1.00Job, iii) Modem with specifications of Fibre Port having ILL, PON &Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1.00No., iv)3 KVA Stabilizer with specifications of 220 V.ACInput/ 220 V.AC output, necessary terminal wires etc., complete complete -1.00No., v) 3 KVA online ups with specifications of 220 V.ACInput/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank,make ofVertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete- 1.00No., vi) 3 in one on line B/W A4 Lazer Jet printer -1.00No., vii) Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication- 1.00Job, |
| 2379 | viii)Establishment of Local SCADA station at Palakonda Municipality with the above specifications. - 1.00 Job |
| 2380 | 3.21.4.2 Development of Softwares for Individual Local Control Station at Individual ULB :: |
| 2381 | a) Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. i) Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user) - 1.00 Job, ii) Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete.- 1.00 job, iii) Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customerat the time of commissioning - 1.00 Nos, iv) Develop, Supply, install and commissioning of Anroid & IO\"s application for data monitoring by through Mobi-APP as required by the customerat the time of commissioningcomplete - 1.00 Nos |
| 2382 | v) Establishment of Local SCADA station at Palakonda Municipality with the above specifications. - 1.00 job |
| 2383 | Bill No:3.22Providing Distribution system with HDPE pipes in Zone - I, II, III, IV |
| 2384 | 3.22.1 Cutting open BT road surface as well as asphalt concrete including water bound macadamand stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 2385 | 3.22.2 Cutting open C.C. road surface including stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 2386 | 3.22.3 Cutting open water bound macadam road including soiling for pipe line trench work. as directed by the departmental officers. |
| 2387 | 3.22.4 BR-FNDN-1- (i-B) - In ordinary soils, by Mechanical meansEarthworkexcavationin all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 2388 | 3.22.5 BLD-CSTN-2-5 - (13): Earth work excavation for foundations and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth |
| 2389 | 3.22.6 RBR-FNDN-1- (i-A) In ordinary soils, by Manual meansEarthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 2390 | 3.22.7 PHE-BHLW-26; Barricading, hoarding, lighting and watching etc., for water supply and sewerage works for trenches of depths upto 6’-0” (2 Meter) below G.L |
| 2391 | 3.22.8 Manufacture, supply, delivery of HDPE PE 100 pipes conforming to IS 4984 - 1995 includingtransportation to any where in AP, Excise duty, sales tax etc., complete ( Supply upto 90mm dia in coil & above 90mm dia strightin length in 6M) (6 Kg/Sq Cm) |
| 2392 | i) 110 mm dia HDPE 6Kg/Cm2 |
| 2393 | ii) 160 mm dia HDPE 6Kg/Cm2 |
| 2394 | iii) 200 mm dia HDPE 6Kg/Cm2 |
| 2395 | iv) 250 mm dia HDPE 6Kg/Cm2 |
| 2396 | v) 315 mm dia HDPE 6Kg/Cm2 |
| 2397 | 3.22.9 Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to any where in AP, Central excise duty, sale taxetc., complete |
| 2398 | 3.22.9.1 Bends |
| 2399 | i)110 mm dia suitable for HDPE 6Kg/Cm2 |
| 2400 | ii) 160 mm dia suitable for HDPE 6Kg/Cm2 |
| 2401 | iii) 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 2402 | iv) 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 2403 | 3.22.9.2 End caps |
| 2404 | i) 110 mm dia suitable for HDPE 6Kg/Cm2 |
| 2405 | ii) 160 mm dia suitable for HDPE 6Kg/Cm2 |
| 2406 | iii) 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 2407 | iv) 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 2408 | 3.22.9.3 Long neck pipe ends |
| 2409 | i) 110 mm dia suitable for HDPE 6Kg/Cm2 |
| 2410 | ii) 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 2411 | iii) 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 2412 | 3.22.9.4 MS flanges to suit HDPE pipes |
| 2413 | i) 110 mm dia |
| 2414 | ii) 160 mm dia |
| 2415 | iii) 200 mm dia |
| 2416 | iv) 250 mm dia |
| 2417 | v) 315 mm dia HDPE |
| 2418 | 3.22.9.5 Tees |
| 2419 | i) 110 mm dia suitable for HDPE 6Kg/Cm2 |
| 2420 | ii) 160 mm dia suitable for HDPE 6Kg/Cm2 |
| 2421 | iii) 200 mm dia suitable for HDPE 6Kg/Cm2 |
| 2422 | iv) 250 mm dia suitable for HDPE 6Kg/Cm2 |
| 2423 | v) 315 mm dia suitable for HDPE 6Kg/Cm2 Tees |
| 2424 | vi) 315 mm dia suitable for HDPE 6Kg/Cm2 Bend |
| 2425 | vii) 315 mm dia suitable for HDPE 6Kg/Cm2 End caps |
| 2426 | viii) 315 mm dia suitable for HDPE 6Kg/Cm2 Pipe end long neck |
| 2427 | 3.22.10 Lowering, laying, jointing & testing of HDPE Pipe line laid to true alignment and gradiant tohydraulic field test pressure per IS codeincluding cost of water with minimum water lead of 500m (Labour charges only)Outer dia of pipes in mm. |
| 2428 | i) 110 mm dia HDPE 6Kg/Cm2 |
| 2429 | ii) 160 mm dia HDPE 6Kg/Cm2 |
| 2430 | iii) 200 mm dia HDPE 6Kg/Cm2 |
| 2431 | iv) 250 mm dia HDPE 6Kg/Cm2 |
| 2432 | v) 315 mm dia HDPE 6Kg/Cm2 |
| 2433 | 3.22.11 Manufacure supply of Centrifugally cast (Spun) Ductile Iron pressure pipes for water, gas and sewage with Socket Spigot ends conforming to IS.: 8329/2000 in standard working lengths of 4, 5 5.5 & 6 meter for classification K9 & K7 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating. Rates are ex-factory, excluding transportation, taxes and duties. |
| 2434 | 350 mm dia DI K7 |
| 2435 | 3.22.12 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.S:1538. - DI. D/F Sluice valves ofPN.1.6 class |
| 2436 | i) 100mm dia Sluice Valves |
| 2437 | ii) 150mm dia Sluice Valves |
| 2438 | iii) 200mm dia Sluice Valves |
| 2439 | iv) 250mm dia Sluice Valves |
| 2440 | v) 300mm dia Sluice Valves |
| 2441 | vi) 350mm dia Sluice Valves |
| 2442 | 3.22.13 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. PN.1.6 class- 80mm dia Air Valve |
| 2443 | 3.22.14 Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13 / IS 9523 / 2000) including transportation but excluding all taxes & duties (with finishings as per Clause 13/IS 9523/2000) |
| 2444 | 3.22.15 Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint),excluding the cost of the gasket but including all sundries filling with water,with a water lead up to 500m and testing to required pressure, etc.complete (Reference to specifications IS 3114 / 1994 / 12888 / 1997) - 350mm dia K7 |
| 2445 | 3.22.16 Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications.BIS No.3114/1994) - 350mm dia K7 |
| 2446 | 3.22.17 PHE-CISV-15 : Lowering, keeping in position and fixingD.I. sluice valves (with cap / with hand wheel & reflex valves)includingcost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 2447 | i) 100mm dia Sluice Valves |
| 2448 | ii) 150mm dia Sluice Valves |
| 2449 | iii) 200mm dia Sluice Valves |
| 2450 | iv) 250mm dia Sluice Valves |
| 2451 | v) 300mm dia Sluice Valves |
| 2452 | vi) 350mm dia Sluice Valves |
| 2453 | 3.22.18 PHE-JCIF-5-: Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 2454 | 100mm dia Sluice Valves |
| 2455 | 150mm dia Sluice Valves |
| 2456 | 200mm dia Sluice Valves |
| 2457 | 250mm dia Sluice Valves |
| 2458 | 300mm dia Sluice Valves |
| 2459 | 350mm dia Sluice Valves |
| 2460 | 3.22.19 Labour charges for fixing Kinetic Air ValvesDouble Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 2461 | 80 mm dia Air Valve |
| 2462 | 3.22.20 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 2463 | Up to200 MM dia Sluice valves |
| 2464 | Up to200 to 350 MM dia valves |
| 2465 | 3.22.21 Supply and filling with crusher dust complying with standard specifications with all leads and lifts in layers consolidating with watering and ramming including cost and conveyance of all materials and labour charges, all taxes, seignorage charges, convey |
| 2466 | 3.22.22 Construction ofun-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. RBR-CCPV-5 for CC Road Restoration |
| 2467 | Bill No: 3.23 Supply and fixing of AMR water meters |
| 2468 | 3.23.1 Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-A. - DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area |
| 2469 | 3.23.2 Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoTin every 24 Hours without fail through the provider registered inDOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication)The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warrantiesand submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-B - Under DMA-1&2 under 500 KL ELSR at At Municipal officewith above specifications |
| 2470 | 3.23.3 Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer. |
| 2471 | Bill No: 3.24 Providing House Service connections at Household side(Minimum 4.0 Mts MDPE pipe) |
| 2472 | 3.23.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A - 0.81 Cum, 3.23.2 Providng House service connectionsonHDPE mains - 3.23.2.1 Providing and Fixing (PP Saddle)PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above. The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. UK and certificate of Compliance to be produced for the following parameters: i) Odour&Flavour of water ii) Appearance of water iii) Growth of Micro Organism |
| 2473 | iv) Extraction of Substances that may be of concern to public health (Cyto toxicity) v) Extraction of Metals excluding all taxes.PP clamp saddle with female threaded out let for 1/2\"(20 mm dia OD) for HSC\"s 15 mm - for main pipes ofHDPE / PVCof 110 mmdia - 1.00 No.3.23.3 Providing flow control valve SS 316 NRV 10 LPM directed by the departmental Engineer in charge, but excluding all taxes. (Quotation) - flow control valve SS 316 NRV - 1.00 No.3.23.4 Supply and delivery of Compression adaptor with one side compression end to suit 1/2 \"to1\"\"(15mmOD to25 mm OD)MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2\" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and \"O\" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos.(For HDPE / PVC/AC /CI/DIPipes) - PP Compression Metal insert female Threaded Adaptor- For1/ 2 \"\"(Table 35Hose service connections of SSR 2025-26 ) - 2.00 Nos, 3.23.5 Supply and delivery of Double compression elbow to suit 1/2 \" to 1\"\" (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and \"O\" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 .(For HDPE / PVC/AC /CI/DIPipes)- Double compression elbow to suit 20 mm OD - For 100 mm (Table 35Hose service connections of SSR 2025-26 )- 2.00 Nos, 3.23.6 Supply and delivery ofMDPE PE80 Blue pipeas per ISO 4427 up to date 1. for conveyance of potable water. The pressure rating of(15mm OD to 25 mm OD)will be PN16. certificate for compliance of testing these fittings and pipe as per BS-6920 by design - MDPE 20mm OD pipe ( 2.00 m avglength for each of 1/2\"\"HSC) of SDR 9-PN - 16 For Pipe Side - 4.00 Rmt, |
| 2474 | 3.23.7 Supply and Fixing of Premium make UPVC Pipes with Fittings.(IS 4985/2000)(PH SSR :20) UPVCpipe for 40 mm of SSR 2025-26 - 1.00 Rmt, 3.23.8 S & F 12.7 mm brass bib cock Indian make heavy duty long body - 1.00 Each, 3.23.9 Fixing of House service connections,including fixing of ferrule, MDPE/GI pipes and specials and connecting newly laid pipe including labour charges,hire charges etc complete(For HDPE / PVC Pipes)- 1.00 Job, 3.23.10 Making Holes upto 18 mm Dia in RCC/any Stones up to 50 mm Thick( BMS-W.78 of SSR 2025-26 - 2.00 Nos, 3.23.11 Supply and Fixing of 25.4 mm Holder Back Clamps at Drain Crossing Including Labour Charges to be Complete(BMW-F96&97) SSR 2025-26 - 2.00 Nos |
| 2475 | Bill No: 3.24 Providing House Service Connection ar Household opposite side in earthern Road (Minimum 7.0 Mts MDPE pipe) |
| 2476 | 3.24.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A - 0.81 Cum, 3.24.2 Providng House service connectionsonHDPE mains, 3.24.2.1 Providing and Fixing (PP Saddle)PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above. The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. UK and certificate of Compliance to be produced for the following parameters: i) Odour&Flavour of water ii) Appearance of water iii) Growth of Micro Organism iv) Extraction of Substances that may be of concern to public health (Cyto toxicity) v) Extraction of Metals excluding all taxes. |
| 2477 | PE 80 electro fusion tapping saddle with female threadedoutletFor 1/2\"\" (20 mm OD ) for HSc\"s 15 mm dia - for main pipes ofHDPE / PVCof 110 mmdia(Table 18.II of SSR 2025-26 - 1.00 Nos., 3.24.3 Providing flow control valve SS 316 NRV 10 LPM directed by the departmental Engineer in charge, but excluding all taxes. (Quotation) - flow control valve SS 316 NRV- 1.00Nos, 3.24.4 Supply and delivery of Compression adaptor with one side compression end to suit 1/2 \"to1\"\"(15mmOD to25 mm OD)MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2\" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and \"O\" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos.(For HDPE / PVC/AC /CI/DIPipes), PP Compression Metal insert female Threaded Adaptor- For1/ 2 \"\" Table 35.1 of SSR 2025-26) - 2.00 nos, 3.24.5 Supply and delivery of Double compression elbow to suit 1/2 \" to 1\"\" (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and \"O\" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 .(For HDPE / PVC/AC /CI/DIPipes) Double compression elbow to suit 20 mm OD - For 100 mm (Table 35Hose service connections of SSR 2019-20 )- 2.00 Nos, 3.24.6 Supply and delivery ofMDPE PE80 Blue pipeas per ISO 4427 up to date 1. for conveyance of potable water. The pressure rating of(15mm OD to 25 mm OD)will be PN16. certificate for compliance of testing these fittings and pipe as per BS-6920 by design - MDPE 20mm OD pipe ( 2.00 m avglength for each of 1/2\"\"HSC) of SDR 9-PN - 16 For Pipe Side- 7.00 Rmt |
| 2478 | 3.24.7 Supply and Fixing of Premium make UPVC Pipes with Fittings.(IS 4985/2000)(PH SSR :20) UPVCpipe for 40 mm of SSR 2025-26 - 7.00 Rmt, 3.24.8 S & F 12.7 mm brass bib cock Indian make heavy duty long body - 1.00 Each , 3.24.9 Fixing of House service connections,including fixing of ferrule, MDPE/GI pipes and specials and connecting newly laid pipe including labour charges,hire charges etc complete(For HDPE / PVC Pipes)- 1.00 Job, 3.24.10 Making Holes upto 18 mm Dia in RCC/any Stones up to 50 mm Thick( BMS-W.78 of SSR 2025-26 - 2.00 Nos, 3.24.11 Supply and Fixing of 25.4 mm Holder Back Clamps at Drain Crossing Including Labour Charges to be Complete(BMW-F96&97) SSR 2025-26 - 2.00 Nos |
| 2479 | Bill No: 3.25 Providing House Service Connection ar Household opposite side in CC & B.T Roads (Minimum 7.0 Mts MDPE pipe) |
| 2480 | 3.25.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A - 0.81 Cum, 3.25.2 Providng House service connectionsonHDPE mains - 3.25.2.1 Horizontal Boring in all soils including Drilling removal earth etc to be complete - 1.00 Job, 3.25.2.2 Providing and Fixing (PP Saddle)PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above. The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. UK and certificate of Compliance to be produced for the following parameters: i) Odour&Flavour of water ii) Appearance of water |
| 2481 | iii) Growth of Micro Organism iv) Extraction of Substances that may be of concern to public health (Cyto toxicity) v) Extraction of Metals excluding all taxes., PP clamp saddle with female threaded out let for 1/2\"(20 mm dia OD) for HSC\"s 15 mm - for main pipes ofHDPE / PVCof 110 mmdia - 1.00 Nos, 3.25.3 Providing flow control valve SS 316 NRV 10 LPM directed by the departmental Engineer in charge, but excluding all taxes. (Quotation) - flow control valve SS 316 NRV -1.00 Nos, 3.25.4 Supply and delivery of Compression adaptor with one side compression end to suit 1/2 \"to1\"\"(15mmOD to25 mm OD)MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2\" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and \"O\" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos.(For HDPE / PVC/AC /CI/DIPipes)-PP Compression Metal insert female Threaded Adaptor- For1/ 2 \"\"(Table 35Hose service connections of SSR 2025-26 ) - 2.00 NOs, 3.25.5 Supply and delivery of Double compression elbow to suit 1/2 \" to 1\"\" (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and \"O\" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 .(For HDPE / PVC/AC /CI/DIPipes) -Double compression elbow to suit 20 mm OD - For 100 mm (Table 35Hose service connections of SSR 2025-26 ) - 2.00 Nos, 3.25.6 Supply and delivery ofMDPE PE80 Blue pipeas per ISO 4427 up to date 1. for conveyance of potable water. The pressure rating of(15mm OD to 25 mm OD)will be PN16. certificate for compliance of testing these fittings and pipe as per BS-6920 by design MDPE 20mm OD pipe ( 2.00 m avglength for each of 1/2\"\"HSC) of SDR 9-PN - 16 For Pipe Side - 7.00 Rmt |
| 2482 | 3.25.7 Supply and Fixing of Premium make UPVC Pipes with Fittings.(IS 4985/2000)(PH SSR :20) UPVCpipe for 40 mm of SSR 2025-26 - 7.00 Rmt, 3.25.8 S & F 12.7 mm brass bib cock Indian make heavy duty long body - 1.00 Each, 3.25.9 Fixing of House service connections,including fixing of ferrule, MDPE/GI pipes and specials and connecting newly laid pipe including labour charges,hire charges etc complete(For HDPE / PVC Pipes) - 1.00 Job, 3.25.10 Making Holes upto 18 mm Dia in RCC/any Stones up to 50 mm Thick( BMS-W.78 of SSR 2025-26 - 2.00 Nos, 3.25.11 Supply and Fixing of 25.4 mm Holder Back Clamps at Drain Crossing Including Labour Charges to be Complete(BMW-F96&97) SSR 2025-26 - 2.00 Nos |
| 2483 | Bill No: 3.26 Hiring for Vehicles for 84 Months on execution period. 2 Nos. x 24 Months x Rs.35000/- per Month. |
| 2484 | Bill No: 3.27 Providing for Implementation of Environmental Management Plan |
| 2485 | 3.27.1 Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 2486 | 3.27.2 Noiselevel(5 Monitoringstation)onceinamonthforthree seasonsduring the constructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 2487 | 3.27.3 Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 2488 | 3.28. Operation and Maintenance work for the water supply improvement scheme and distribution network in Palakonda Nagar Panchayat. |
| 2489 | 3.28.1 OPERATION & MAINTENANCE COST (ExcludingEnergy charges ) forSeven Years including two years defect liability period |
| 2490 | 3.28.1.1 Man Power |
| 2491 | i) Personal required for operating Intake/Offtake well/Pump houses |
| 2492 | Operator |
| 2493 | ii)Personal required at operating Clear water rising mains |
| 2494 | Fitter/Helper |
| 2495 | iii) Personal required at operating Service reservoirs |
| 2496 | Watchman |
| 2497 | iv) Personal required at operating distribution system |
| 2498 | Fitter/Helper |
| 2499 | Consumables for 7 years |
| 2500 | A) Chlorine gas for Disinfection @ 3 mg/Lt |
| 2501 | Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines. |
| 2502 | Repairs to pumpsets & Water pipe lines(2 years after execution period) |
| 2503 | i) Replacement of bearings of pumpsets |
| 2504 | ii) Replacement of sleeves |
| 2505 | iii) Raw Water Motors |
| 2506 | Clear water Motors |
| 2507 | iv)Replacement of glands of sluice valves |
| 2508 | v) Replacements of balls of Air valves |
| 2509 | vi) Greease |
| 2510 | vii) Gland Packing |
| 2511 | Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete |
| 2512 | 300 mm HDPE Pipes |
| 2513 | 250 mm HDPE Pipes |
| 2514 | 200 mm HDPE Pipes |
| 2515 | 160 mm HDPE Pipes |
| 2516 | 110 mm HDPE Pipes |
| 2517 | 3.28.2 Operation & Maintenance cost Local SCADA at ULB |
| 2518 | Jr. Service Engineer(Diploma Engineer)Rate as per Labour Rates LAB-00127 of CSSR 2025-26 |
| 2519 | Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-26 |
| 2520 | Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 |
| 2521 | Hiring of vehicle (4 wheeler)Rate as per G.O.MS.No.87Dated 01-06-2017. |
| 2522 | 3.28.2.2 MAINTAINANCE OF LOCAL CONTROL STATION : |
| 2523 | i) Replacement of necessary servicable materials(Reagents) for Chlorine Analysers*Each Reagent bottle willwork for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. |
| 2524 | Raw Water Inlet of Water Treatment plant - Inlet of 400 KL Existing ELSR at Municipal office , Inlet of 500 KL Proposed ELSR at Municipal office , Inlet of 500 KL Proposed ELSR at Venkaipeta, Inlet of 500 KL Proposed ELSR at Vadama, Inlet of 500 KL Proposed ELSR at Rajapuram |
| 2525 | ii) Replacement of necessary tranducers for PH analysers |
| 2526 | Raw Water Inlet of Water Treatment plant |
| 2527 | iii)Replacement of necessary tranducers for Turbidity analysers |
| 2528 | Raw Water Inlet of Water Treatment plant |
| 2529 | iv) BSNL Charges for static IP - Interconnection for Data receive station from all Local Contol RTU panels. |
| 2530 | GPRS Connections |
| 2531 | Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attendin |
| 2532 | 3.28.3 Operation & Maintenance cost Central SCADA for ULB |
| 2533 | Application Engineer (Graduate Engineer)Rate as per Labour Rates LAB-00130 ofCSSR 2025-26 |
| 2534 | System Engineer (Diploma Engineer)Rate as per Labour RatesLAB-00130 ofCSSR 2025-26 |
| 2535 | Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-26 |
| 2536 | Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 |
| 2537 | II) MAINTAINANCE OF LOCAL CONTROL STATION : |
| 2538 | BSNL Charges for static IP |
| 2539 | Data base management for WEB reporting |
| 2540 | Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
| 2541 | 3.28.4 Providing for Implementation of Environmental and Social Management Plan |
| 2542 | 3.28.4.1 Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 2543 | 3.28.4.2 Noiselevel(5Monitoringstation)onceinamonthforthree seasonsduring the constructionperiodat intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 2544 | 3.28.4.3 Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 2545 | 3.28.4.4 Compensatory plantation andthree years maintenance (Compensatory afforestation ratio is 1:5) |
| 2546 | 3.28.4.5 Sprinkling of wateronce in a day fortwo years (excluding rainy days):500 days @ Rs.1000/trip |
| 2547 | 4. Salur Municipality |
| 2548 | BILL No.4.1 Construction of 8.0mts dia Raw water Intake well cum pump house at Peddagadda reservoir. |
| 2549 | 4.1.1Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width (RBR-FNDN-1). |
| 2550 | 4.1.2Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth-Hard rock (blasting prohibited) Upto 3 m depth including 1.5 m depth in hard rock |
| 2551 | 4.1.3 Plain Cement Concrete (1:4:8)using 40mmmetal (2/3 rd) & 20mm graded nominal size (1/3rd) HBG machine crushed metal (1 Cement : 4 Sand :8 Coarse aggregate) including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete including VAT and labour cess. |
| 2552 | 4.1.4 RCC in M 30Grade design mix using 20mm down graded SS-5 HBG m/c metal , coarse and fine aggregates conforming to IS: 383,as permix design for Fair degree of quality control) including cost and conveyance of all materials, machinery,all labour charges , machine mixing, vibration, curingand all incidental & operational chargesetc. complete conforming to standard specification but excluding cost & conveyance of reinforcement and its fabrication charges including VAT and labour cess. |
| 2553 | 4.1.5 Raft Slab at 194.0mts |
| 2554 | 4.1.6 Sidewalls of intakewell from 194mts to 197.0mtsbed level |
| 2555 | 4.1.7 Side wall from 197.0mtsto 200.0mts |
| 2556 | 4.1.8 Sidewalls from 200.0mts to 201.0mts |
| 2557 | 4.1.9 Sidewalls from 202mts to 203.0mts |
| 2558 | 4.1.10Sidewalls from 203.0mts to 204.0mts |
| 2559 | 4.1.11 Sidewalls from 204.0mts to 205.0mts |
| 2560 | 4.1.12 Sidewalls from 205.0mts to 206.00mts |
| 2561 | 4.1.13 Sidewalls from 206.0mts to 207.00mts |
| 2562 | 4.1.14Sidewalls from 207.0mts to 208.00mts |
| 2563 | 4.1.15Sidewalls from 208.0mts to 209.00mts |
| 2564 | 4.1.16 Sidewalls from 209.0mts to 210.00mts |
| 2565 | 4.1.17Sidewalls from 210.0mts to 211.00mts |
| 2566 | 4.1.18 Sidewalls from 211.0mts to 212.00mts |
| 2567 | 4.1.19 Sidewalls from 212.0mts to 213.00mts |
| 2568 | 4.1.20Sidewalls from 213.0mts to 214.00mts |
| 2569 | 4.1.21 Sidewalls from 214.0mts to 215.00mts |
| 2570 | 4.1.22 Sidewalls from 215.0mts to 216.00mts |
| 2571 | 4.1.23 Sidewalls from 216.0mts to 217.00mts |
| 2572 | 4.1.24Floor Slab (400 mm thick) at level +216.30mts |
| 2573 | 4.1.25Columns from floor level to Roof level i.e from 216.30mts to 222.30mts |
| 2574 | 4.1.26Lintel Beam above rolling shutters and windows |
| 2575 | 4.1.27Sunshades |
| 2576 | 4.1.28 Ring beam at support of crane |
| 2577 | 4.1.29 Roof Beams at 222.30mts |
| 2578 | 4.1.30Roof Slab400 thick |
| 2579 | 4.1.31 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials andfor finished item of work. |
| 2580 | 4.1.32 Brick work in C.M. (1:6) prop using 2nd class well burntgrounded mouldedbricks including cost and conveyance of all materials, seigniorage, sales tax onall materials, labour charges, including mortar mixing, scaffolding, laying, curing, finishing as per SS |
| 2581 | 4.1 .33 Plastering with CM (1:3) 20mm thick including cost and conveyance of all materials at sitelabour charges for finishing and curing etc., complete as per S.S for the Pump house |
| 2582 | 4.1 .34 Plastering with CM (1:5) 12mm thick including cost and conveyance of all materials at sitelabour charges for finishing and curing etc., complete as per S.S for the Pump house |
| 2583 | 4.1 .35 Providing two coats of Snowcem Paint of approved colour to exterior surfaces over one coat primer including cost & conveyance of all materials,labour charges etc., complete including VAT and labour cess. |
| 2584 | 4.1 .36 Painting to new walls with 2 coats of water proof cement paint of apporved brand and shade over a base coat of approved cement primer grade I making making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 912 for externalwalls |
| 2585 | 4.1 .37 Supplying and fixing of Rolling shutter made of 80X 1.25 mm machine rolled lathesincluding top cover, bearings, and locking arrangements , a coat of red oxide primer etc complete as per SS |
| 2586 | 4.1.38 Painting with Synthetic Enamel paints - Two Coats - For New Iron Work complete as per SS |
| 2587 | 4.1.39 Providing and fixing of Openable Windows made of pre-painted steel (Base steel as per IS 513 of 0.58 mm thick galvanized as per IS 277 with Zinc of 120 GSM), primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7micronsthick alkyd backer and section for outer frame of 48 x 50 mm, centre mullionof 48 x 50 mm, section for shutter of 48 x 25 mm and the fixed glass beadingsection should be 12 x 12 mm and the outer frame and mullions to haverebate for glazed shutter with a 20 mm provision for guard bars/grills and thesections cut to length metre joined with corner bracket, centre mullion fixedwith mullion cap, handle, stay, 2 nos. of stainless steel heavy duty pivot hingesprovided per shutter and windows fitted with 5 mm thick plain float glass withrubber gaskets including fixing the frames in concrete/masonry wall by meansof self expanding screws, Including 10mm Square guard bars with 6”(152.4mm) pitch etc., complete for finished item of work. |
| 2588 | 4.1.40 Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work complete as per SS |
| 2589 | 4.1.41 Manufacture, supply, delivery and erection of 3 tonnes capacity circular double girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of best quality 250 x 125 mm of standard make, including the required 500*180ISMB, 150x75 ISMB, 3 tonne capacity travelling trolley and 3 tonne capacity chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 12 m rate is inclusive of the cost of materials, labour charges, site welding etc., including cost of necessary civil works complete as per SS |
| 2590 | 4.1.42 electrification |
| 2591 | 4.1.43 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chagesunit 1.00 Rmt BLD-ELEC-1-4 |
| 2592 | 4.1.44 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages unit 1.00 Rmt BLD-ELEC-1-4 |
| 2593 | 4.1.45 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building- for 6 pointsunit eachBLD-ELEC-2-1 |
| 2594 | 4.1.46 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges unit each BLD-ELEC-2-1-3 |
| 2595 | 4.1.47 Supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges etc.,unit 1.00 rmtBLD-ELEC-3-1- |
| 2596 | 4.1.48 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. unit 1.00 rmtBLD-ELEC-3-1-2 |
| 2597 | 4.1.49 supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,unit 1.00 rmtBLD-ELEC-6-1-4 |
| 2598 | 4.1.50 Providing independent earthing by excavating a trench toa depyh of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc completeunit eachBLD-ELEC-5-1-1 |
| 2599 | 4.1.51Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete. BLD-ELEC-4-4.1 |
| 2600 | 4.1.52 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 2601 | 4.1.53 Supply of 9\" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT-1.7.1 L |
| 2602 | 4.1.54 Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.-ELEC5.1.12 |
| 2603 | 4.1.55 Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 2604 | 4.1.56 Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete |
| 2605 | 4.1.57 Labour charges Fixing of 20W tube light luminaire on wall / Ceiling with/ TW round blocks with all accessories including giving connections and all labour charges etc., complete. |
| 2606 | BILL NO.4.2Construction of coffer damby providingimpervious earthen bund with selected soil from approved borrow areas for construction of intake wellin Peddagadda reservoir |
| 2607 | 4.2.1Providing impervious hearting embankment with selected soil from approved borrow areas in layers of 25cm before compaction including cost of all materials, machinery, labour, all operations such as excavation, sorting out, transporting, spreading in layer of specified thickness, breaking clods, sectioning, watering, compacting each layer to density control of not less than 98 percent or as stipulated by sheep / pad foot roller etc., complete with initial lead upto 5 km and all lifts. |
| 2608 | 4.2.2 Bailing out water from Pipe line trenches with oil driven pumpsets, including hire charges, fuel charges for driver & helper etc., complete as per SS |
| 2609 | 4.2.3 Excavation and removal of silt or silt mixed with sand in slussy condition from canal bed including disposing off the same in spoil bank or on the canal embankment in layers as directed etc., complete with initial lead upto 50 m and all lifts. |
| 2610 | 4.2.4 supply and packing of EC bags filled with sand including cost of sand , EC bags , Fillinf charges, stiching charges with country thread, conveyance to the site palcing on position and etc com |
| 2611 | BILL NO.4.3 Construction of Walk waybridgeto intake well cum pump house in Peddagadda reservoir. |
| 2612 | 4.3.1Earthwork excavation and depositing on the bank in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel and soft disintegrated rock, like shelves,stonematrix, removable by pickaxes and crow barsfor pipeline trenches and as per specification drawings and as directed by the departmental officer with an initial lead of 50 M and with all lifts and delifts for pipe line trenchesetc., complete. |
| 2613 | 4.3.2 Supply, collection , stacking & filling of sand for beddingincluding cost & conveyance of all materials & labour charges, seignorage charges, filling tamping charges etc complete as per SS |
| 2614 | 4.3.3 Plain Cement Concrete (1:4:8)using 40mmmetal (2/3 rd) & 20mm graded nominal size (1/3rd) HBG machine crushed metal (1 Cement : 4 Sand : 8 Coarse aggregate) including costand conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete as per SS |
| 2615 | 4.3.4 RCC M- 30 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work |
| 2616 | A)Footings |
| 2617 | B)Beams |
| 2618 | C)Column |
| 2619 | D) Walkway Slab 150 mm thick (@ +116.82mtslevel) |
| 2620 | 4.3.5Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars of Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, |
| 2621 | 4.3.6 Supplying, fitting and placing of MS pipes and specials including cost and fabrication charges complete as per drawings and technical specifications including wastage, etc complete as pee ss |
| 2622 | BILL NO.4.4 Supply, delivery, and erection of Raw water Vertical turbine Pumpsetshaving a discharge of 147 lps against a head of 30 mts of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformet to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete(2 Nos- 75 KW to pump water from Intake well to Raw water sump. |
| 2623 | 4.4.1 Providing Raw Water Pumping system at Pedagedda reservior by supply, delivery and erection ofVT pump set with specifications ofHead range of 48 mtrs, discharge of 385 M3/Hr for Raw Water(1 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 2624 | a) Supply and Delivery of Verticle Turbine (VT) Pump set: Supply, erection, testing and commissioning ofVertical Turbine pump ( VT pump set) with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing and belmouth with cast iron, impeller, shaft sleeves,muff coupling units-CF-8M ,shaftSleeves and wearings withbronze, shaft with SS410, throdenbering with Bronze with rubber lined, suitable shaft sealing system with stuffing box arrangement, provison for , fixing of suitable diapressure guages with Gliseron filling and the pump driven withLT Squirrel cage inductionDrive rated Motor (Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM suitable for pump selection solid shaft TEFC enclosure, IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Coupling, coupling guard and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractorb)Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing. c) Internal Pipe lines: Sucttion Lines : Supply, laying and jointing of suitable size ofDI/ MSFlanged pipes from sump to pump by connecting with MS Concentric tapperDeviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance. |
| 2625 | d) Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction.C. Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.D.fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.e) Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connectedVaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete.f) Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete i) Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer ii) Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare iii) Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station iv) ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumpsv) Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panelg) Supply, laying, termination and testing suitable capacity of1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) |
| 2626 | h) Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.1) Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;i) Ring Spanner 3/16 to 1\" ii)Double end spanner set 3/16\" to 1\"iii)Pipe Wrench 18\" & 4\"iv) Screw drivers 6\", 10\" & 12\" v) Cutting Plier 12\" vi) 2 Kgs Hammer with Handle vii) Nose Plier viii) Flat and Half round smooth fileix) Adjustable Spanner 6\"x) Column pipe Clamps xi) Line Shaft Clampsxii) Line rope and clamps double the weight of pump xiii) Gland thghtening Spanner xiv) Spitter removing Spanner |
| 2627 | j) Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; completei) Fire extiguisher 3Kg capacity ii) Rubber Mat 6\" x 4\" iii) Fire Buckets with stand and three buckets iv) Rubber Hand Gloves v) Danger Board Plates vi) First aid kit with chart vii) Shock Treatment Chart viii) Portable rechargeble torch lightix) Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;k) Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,l) All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field Engineerm) Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection |
| 2628 | 4.4.2 Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 2629 | A) VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector controlB) Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feederC) Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder D) Power transformer, required push buttons and MFM for each Main pump feeder |
| 2630 | CAP BILL 4.5 Supply delivery and erection of 250 KVA transformer of standard make as per standard specifications including all accessories, yard development as per IE rules , including dedicated feeder mainincluding all taxes duties and labour charges etc.complete near intake well at Peddagadda reservoir |
| 2631 | 4.5.1Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 2632 | 4.5.2 Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 2633 | 4.5.3 Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 2634 | 4.5.4 Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 2635 | 4.5.5 Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 2636 | 4.5.6Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 2637 | 4.5.7 Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 2638 | 4.5.8 Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3B/MAT 04097 |
| 2639 | 4.5.9 Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 2640 | A) Earth Electrodes |
| 2641 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 2642 | C) Epoxy insulators |
| 2643 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 2644 | 4.5.10 Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-04044c 250KVA |
| 2645 | 1. Quantity : 12. Rated KVA :250 KVA3. Service & Location: Continuous Outdoor Distribution Transformer4. Mounting : Plinth.5. Wound : CopperDouble wound6. Type :Core type oil immersed7. Cooling : ONAN8. TempRise : 40⁰C in oil 45⁰C by resistance9. Vector Group:Dyn 1110. Primary Connection :Delta11. Nominal Voltage / Current : ______12. Highest system Voltage: 12000V13. Primary Frequency :50 HZ +/- 3%14. Number of Phases : 315. Primary wires:316. Secondary connection : Star17. SecondaryVolts / Current :433V18. Secondary phases :319. Secondary wires:420. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps)21. Terminal arrangement. a.HV: HT terminal box as per the site condition.b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable22. LV:One separate terminal for earthing.23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats25. Percentage Impedance at 75 deg C AT 4.526. No load Current Less than 2% of full load Current 27. Standrad Fittings & Accessories.a. Rating and terminal marking plate: Oneb. Lifting Lugs:Two c. Off-circuit tap switch :One d. EarthingTerminals :Two e. Radiators ( Attachable):Adequate f.Explosion vent with Diaphragm :One g. Conservator with Drain plug:oneh. Oil filling hole with cap :Onei.Oil level indicator : One j.Dehydrating Silicagel Breather : Onek. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing: One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type) |
| 2646 | 4.5.11 Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 2647 | 4.5.12 LT PANAL Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 2648 | 4.5.13 Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 2649 | 4.5.13.1 Incoming |
| 2650 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2651 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 2652 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 2653 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 2654 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 2655 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 2656 | g).3RYB Phase indication lamps with leds |
| 2657 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 2658 | 4.5.13.2 Out-Going |
| 2659 | A)630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2660 | B)630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2661 | C)630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2662 | D)630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2663 | E)630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2664 | F)630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 2665 | .G)KWH digital meter fro lighting section |
| 2666 | H)Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 2667 | I)Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 2668 | J)Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 2669 | 4.5.14. 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 2670 | 4.5.15. Supply and Laying of 3C X50Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03457b |
| 2671 | 4.5.16 Transformer Yard |
| 2672 | 4.5.16.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means |
| 2673 | A)column footings |
| 2674 | 4.5.16.2 Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 2675 | A)column footings |
| 2676 | 4.5.16.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 2677 | A)column footings |
| 2678 | 4.5.16.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etcM20 design mix concrete |
| 2679 | A)column footings |
| 2680 | B)Columns1.20-0.10-0.10-0.30+1.80 |
| 2681 | Plinth beam2(15+12)=54-gate3.00=51.00deduct columns |
| 2682 | 4.5.16.5 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 2683 | 4.5.17 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 2684 | column footingsColumnsPlinth beams |
| 2685 | 4.5.18 Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). BLD-CSTN-13-7 |
| 2686 | 4.5.19 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 2687 | A) Gate 3.00m wide |
| 2688 | 4.5.20 Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 2689 | A) Gate 3.00m wide |
| 2690 | 4.5.21 supply and filling the transformer yard with 40mm HBG metal m/c |
| 2691 | BILL NO.4.6Design and Construction of 7.00 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using sand as filter media, compatible with SCADA arrangements in which all valves in filtration plant should be compatible for operation with motorized actuators integrated to SCADA , duly following relevant IS codes in the design of plant components including trial running for 90 days etc., including chlorine contact tank & consumables etc. complete near head works at Pedagadda reservoir |
| 2692 | 4.6.1Construction of7.0MLDcapacity Rapid gravity filtration plant including civil, Mechanical, Electrical,Trial run for 23.50 hours per day work 25% over loading |
| 2693 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width (RBR-FNDN-1) |
| 2694 | Supply and filling with crusher dust complying with standard specifications with all leads and lifts in layers consolidating withwatering and ramming including cost and conveyance of all materials and labour charges, all taxes, segniorage chareges, conveyance of sand including loading, unloading etc., complete as per SS and as directed by the departmental officer in charge of the work for filling of the foundation and basement. |
| 2695 | Plain cement concrete in (1:4:8) prop using 40 mm nominal size hard brokenmachine crushed granite metal as per SS including cost and conveyance of all materials, seignarage, sales taxand labour charges such as mixing concrete, laying, tamping, curing all operational, incidental charges etc., complete as per SSfor finished item of work for building foundation concrete. |
| 2696 | (BLD-CSTN 2-15) - RCC M- 25 DESIGN mix corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal from approved quarry including cost and conveyance of all materials like cement, fine aggregate,coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges including centering, shuttering, machine mixing, laying concrete, vibrating, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work. |
| 2697 | Column footings |
| 2698 | Plinth beam |
| 2699 | Columns |
| 2700 | Beam over compound wall |
| 2701 | Suply of HYSD Fe 415 grade steel including cost and conveyance to site and labour charges including cutting, bending, binding, fabrication of reinforcementincluding cost of binding wire etc. complete for reinforcement |
| 2702 | Brick masonry with fly ash cement bricks in cement mortor (1:6) propertion. This rateis includingcost and conveyanceof materials to site, seigniorage fee,all taxes, lifting charges, mixing of cement mortar, all labour charges,watering, curing, including all scaffolding and all water lead charges etc., complete as per SS and as directed by the departmental officer in charge of the work for |
| 2703 | Plastering 12mm thick with cement mortar CM (1:4) including cost and conveyanceof all materials to site and seignorage fee, screening and mixing, laying, scoffolding, liftingand watering, curing including all labour charges, hire and operational charges and all taxes etc., complete as per SS and as directed by the departmental officer in charge of the work for the following item of work for Ground Floor |
| 2704 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification-external walls |
| 2705 | Provding suitable arnamental MS gates including cost of fixing and painting the gate with suitable paits over two coats of red oxide and all other materials required as per the approved drawing and as directed by the departmental engineers in charge. |
| 2706 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A |
| 2707 | Filling in foundation trenches with stone dustas per drawing and technical specification Clause 305.3.9 MORD & 304 MORTHfor foundations of cc drains and pipe line trench RBR-FNDN-2(1) |
| 2708 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 2709 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 2710 | column footings |
| 2711 | Columns |
| 2712 | Plinth beam |
| 2713 | Lintle beamsWindows |
| 2714 | Roof Beams |
| 2715 | Roof slab0.125m thick with 0.30m extension all sides |
| 2716 | Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 2717 | Loft slab 0.075m thick kitchen |
| 2718 | Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 2719 | Ground Floor |
| 2720 | 1st floor |
| 2721 | Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 2722 | Ground Floor |
| 2723 | 1st floor |
| 2724 | Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 2725 | Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 2726 | inside |
| 2727 | Outside |
| 2728 | Supply delivery and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 2729 | Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 2730 | Door -D - 1.20X2.10 m |
| 2731 | doorsD1 -1.0X2.10m |
| 2732 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 2733 | windows 1.20x1.20 |
| 2734 | Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 2735 | Toilet door D2 |
| 2736 | Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 2737 | Toilet door D2 |
| 2738 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 2739 | Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 2740 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 2741 | Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 2742 | Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 2743 | Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour charges |
| 2744 | Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges |
| 2745 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 2746 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 2747 | supply andrun of 2 of36/0.3 mm. (2.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 2748 | supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 2749 | supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 2750 | Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 2751 | Supply and fixing SPN Distribution board with IP-30 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete |
| 2752 | Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 2753 | Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 2754 | Supply of 1 x 36/40W Box type tube light luminaire powder coated CRCA sheet steel housing with Electronic Ballast Chokes and all standard accessoriesof makes Wipro / G.E. / Phillips / Crompton / Bajaj. |
| 2755 | Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 2756 | Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 2757 | Supplying & Fixing low down porcelain flushing tank 10 Lit Capacity Hindustan Sanitary ware/ parry/ Neycer with internal components |
| 2758 | Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 2759 | Supply of 110 mm dia 3 M single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 2760 | Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 2761 | Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 2762 | Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 2763 | Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 2764 | S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 2765 | 25 mm dia nominal bore -from tank to jn forof individual lines |
| 2766 | 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 2767 | 15 mm dia nominal bore -for internal |
| 2768 | S&F of GI &GM fittings |
| 2769 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 2770 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 2771 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 2772 | S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 2773 | S& F GI union Ist Quality |
| 2774 | 12.70mm |
| 2775 | 19.05mm |
| 2776 | 25.40mm |
| 2777 | For septic Tank |
| 2778 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD.Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth |
| 2779 | Filling with stone dustin foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 2780 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 2781 | Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 2782 | Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 2783 | RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 2784 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 2785 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH By Mechanical Means |
| 2786 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH by Manual means |
| 2787 | Excavation in Hard Rock (blasting prohibited) :Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 MORD / 301 MORTH by Manual Means |
| 2788 | P.C.C. (1:4:8) using 40mm (SS-5) HBG M/C Metal and Opc course and fine agregates conforming to IS:383 including cost and conveyance of all materials, Labour charges, Machine Mixing, vibrating, centring, laying in position curing for 21 days |
| 2789 | RCC M- 30 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of workincludingcentering, shuttering. |
| 2790 | a) FloorSlab |
| 2791 | Base slab |
| 2792 | b) Sidewalls of Sump |
| 2793 | Outer wall 300 mm thick |
| 2794 | Supply and Delivery of HYSD Fe 415 grade reinforcement steel including cost and conveyance to site and labour charges, cutting, bending, fabrication, bindingof reinforcementincluding cost of binding wire etc. complete as per SS but including all taxes |
| 2795 | Cement plastering 12 mm thick towalls in C.M. (1:4)including cost & conveyance of all materials and labour chrages curing etc, complete |
| 2796 | Providing and Constructing 45 cm thick dry rubble stone pitching including cost of all materials,labour,hand packing,finishing etc.,complete |
| 2797 | Earth work excavation and depositing on bank with an initial lead of 10 mts and lift of 2 mts for loamy, clayey soils like black cotton soils, all taxes,red earth, ordinary gravel,soils includingcost and conveyance of alllabour charges etc., complete as per SSandas directed by the departmental officer in charge of the work for foundations of the building. |
| 2798 | Earthwork excavation and depositing on bank in ordinary rock and boulders more than 3 Cum in sizeas per specification drawing and as directed by departmental officers |
| 2799 | Supply and spreading of quarry dust including watering, tampingincluding cost and conveyance of all materials and labour charges etc complete |
| 2800 | Plain cement concrete in (1:3:6) prop using 20 mm nominal size hard brokenmachine crushed granite metal as per SS including cost and conveyance of all materials, seignarage, sales taxand labour charges such as mixing concrete, laying, tamping, curing all operational, incidental charges etc., complete as per SSfor finished item of work for building foundation concrete. |
| 2801 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 2802 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth |
| 2803 | Supply and filling with Sand at bottom of drain including cost and conveyance of all materials and labour charges etc complete |
| 2804 | Laying of VCC (1:3:6) using 20 mm (SS-5) graded HBG m/c metal and OPC coarse and fine aggregates conforming to IS 383 includingcost and conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing for 21 side walls |
| 2805 | RCC M- 20 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, but excludingcentering, shuttering. |
| 2806 | CAPBill No:4.7 Supply, delivery, and erection of Clear water Horizontal split casing CentrifugalPumpsetshaving a discharge of 97 lps against a head of 35 mts of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformet to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete(2 Nos- 55 KW) to pump water from clear water sumpto proposed300 KL GLBR |
| 2807 | 4.7.1 Supply, delivery and erection ofHSC pump set with specifications ofHead range of 35 mtrs, discharge of 349 M3/Hr for Clear Water(1 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 2808 | Supply and Delivery of HSC Pump set: Suitable capacity of HSC pump set with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing with cast iron, impeller andwearings with SS CF 8M,shaftand shaft Sleeves with ASTM A276-Gr-410, arrangement of gland packing, cooling system,provison for vacume arrangementand the pump driven withLT Squirrel cage inductionDrive rated Motor (Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM suitable for pump selection solid shaft TEFC enclosure, IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Coupling, coupling guard and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractorErection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing. Internal Pipe lines: Sucttion Lines : Supply, laying and jointing of suitable size ofDI/ MSFlanged pipes from sump to pump by connecting with MS Concentric tapperDeviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance.Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction.C. Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.D.fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connectedVaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete. |
| 2809 | Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumpsMultifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panelSupply, laying, termination and testing suitable capacity of1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) |
| 2810 | Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;Ring Spanner 3/16 to 1\" Double end spanner set 3/16\" to 1\"Pipe Wrench 18\" & 4\"Screw drivers 6\", 10\" & 12\" Cutting Plier 12\" 2 Kgs Hammer with Handle Nose Plier Flat and Half round smooth fileAdjustable Spanner 6\"Column pipe Clamps Line Shaft ClampsLine rope and clamps double the weight of pump Gland thghtening Spanner Spitter removing Spanner |
| 2811 | Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; completeFire extiguisher 3Kg capacity Rubber Mat 6\" x 4\" Fire Buckets with stand and three buckets Rubber Hand Gloves Danger Board Plates First aid kit with chart Shock Treatment Chart Portable rechargeble torch lightSupply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field EngineerTesting and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection |
| 2812 | 4.7.2 Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 2813 | VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector controlSuitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feederSuitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder Power transformer, required push buttons and MFM for each Main pump feeder |
| 2814 | CAP BILL No. 4.8Supply, delivery, and erection of Clear water Horizontal split casing CentrifugalPumpsetshaving a discharge of 34 lps against a head of 55 mts of standard make as per relevant I.S specifications including cost of pumpsets, D.I Sluice valve, D.I Reflux valve, suction and delivery pipe connections with D.I pipes as per approved design and as per site requirement, suitable capacity Panel Board, suitable capacity cable from transformet to panel board, erection of pumpsets, panel board, all pipe connections, valves , including trial run and commissioning etc complete to pump water from clear water collection wellat Kakula thota to proposed/exisitng ELSRs.(2 Nos-30KW) from old pumphouse Kakula thota to proposed 800 KL ELSR at Gandhi Park |
| 2815 | 4.8.1 Supply, delivery and erection ofSubmersible pump set with specifications ofHead range of 55 mtrs, discharge of 122 M3/Hr for Clear Water(1 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 2816 | Supply and Delivery of HSC Pump set: Suitable capacity of HSC pump set with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing with cast iron, impeller andwearings with SS CF 8M,shaftand shaft Sleeves with ASTM A276-Gr-410, arrangement of gland packing, cooling system,provison for vacume arrangementand the pump driven withLT Squirrel cage inductionDrive rated Motor (Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM suitable for pump selection solid shaft TEFC enclosure, IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Coupling, coupling guard and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractorErection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing. Internal Pipe lines: Sucttion Lines : Supply, laying and jointing of suitable size ofDI/ MSFlanged pipes from sump to pump by connecting with MS Concentric tapperDeviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance.Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction.C. Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.D.fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connectedVaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete. |
| 2817 | Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumpsMultifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panel |
| 2818 | Supply, laying, termination and testing suitable capacity of1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;Ring Spanner 3/16 to 1\" Double end spanner set 3/16\" to 1\"Pipe Wrench 18\" & 4\"Screw drivers 6\", 10\" & 12\" Cutting Plier 12\" 2 Kgs Hammer with Handle Nose Plier Flat and Half round smooth fileAdjustable Spanner 6\"Column pipe Clamps Line Shaft ClampsLine rope and clamps double the weight of pump Gland thghtening Spanner Spitter removing Spanner Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; completeFire extiguisher 3Kg capacity Rubber Mat 6\" x 4\" Fire Buckets with stand and three buckets Rubber Hand Gloves Danger Board Plates First aid kit with chart Shock Treatment Chart Portable rechargeble torch lightSupply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc; |
| 2819 | Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field EngineerTesting and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection |
| 2820 | 4.8.2 Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 2821 | VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector controlSuitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feederSuitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder Power transformer, required push buttons and MFM for each Main pump feeder |
| 2822 | CAP BILL NO 4.9 Supply delivery and erection of 500 KVA transformer of standard make as per standard specifications including all accessories, yard development as per IE rulesincluding dedicated feeder main and labour charges etc.complete at Kakula thota Head works. |
| 2823 | 4.9.1 Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 2824 | 4.9.2 Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 2825 | 4.9.3 Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 2826 | 4.9.4 Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 2827 | 4.9.5 Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 2828 | 4.9.6 Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 2829 | 4.9.7 Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 2830 | 4.9.8 Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 2831 | 4.9.9Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 2832 | A) Earth Electrodes |
| 2833 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 2834 | C) Epoxy insulators |
| 2835 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 2836 | 4.9.10 Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-04046e 500KVA |
| 2837 | 1. Quantity : 12. Rated KVA :500 KVA3. Service & Location: Continuous Outdoor Distribution Transformer4. Mounting : Plinth.5. Wound : CopperDouble wound6. Type :Core type oil immersed7. Cooling : ONAN8. TempRise : 40⁰C in oil 45⁰C by resistance9. Vector Group:Dyn 1110. Primary Connection :Delta11. Nominal Voltage / Current : ______12. Highest system Voltage: 12000V13. Primary Frequency :50 HZ +/- 3%14. Number of Phases : 315. Primary wires:316. Secondary connection : Star17. SecondaryVolts / Current :433V18. Secondary phases :319. Secondary wires:420. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps)21. Terminal arrangement. a.HV: HT terminal box as per the site condition.b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable22. LV:One separate terminal for earthing.23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats25. Percentage Impedance at 75 deg C AT 4.526. No load Current Less than 2% of full load Current 27. Standrad Fittings & Accessories.a. Rating and terminal marking plate: Oneb. Lifting Lugs:Two c. Off-circuit tap switch :One d. EarthingTerminals :Two e. Radiators ( Attachable):Adequate f.Explosion vent with Diaphragm :One g. Conservator with Drain plug:oneh. Oil filling hole with cap :Onei.Oil level indicator : One j.Dehydrating Silicagel Breather : Onek. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing: One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type) |
| 2838 | 4.9.11Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 2839 | 4.9.12 LT panel |
| 2840 | 4.9.12.1 Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 2841 | 4.9.12.2 Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 2842 | 1) Incoming |
| 2843 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2844 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 2845 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 2846 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 2847 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 2848 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 2849 | g).3RYB Phase indication lamps with leds |
| 2850 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 2851 | 2)Out-Going |
| 2852 | A)630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2853 | B)630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2854 | C)630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2855 | D)630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2856 | E)630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 2857 | F)630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 2858 | .G)KWH digital meter fro lighting section |
| 2859 | H)Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 2860 | I)Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 2861 | J)Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 2862 | 4.9.131000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 2863 | 4.9.14 Supply and Laying of 3C X 95Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03460 |
| 2864 | 4.9.15 Transformer yard |
| 2865 | 4.9.15.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means |
| 2866 | A)column footings |
| 2867 | 4.9.15.2 Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 2868 | A)column footings |
| 2869 | 4.9.15.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 2870 | A)column footings |
| 2871 | 4.9.15.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etcM20 design mix concrete |
| 2872 | A)column footings |
| 2873 | B) Columns1.20-0.10-0.10-0.30+1.80 |
| 2874 | C) Plinth beam2(15+12)=54-gate3.00=51.00 |
| 2875 | 4.9.15.5 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 2876 | 4.9.15.6 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 2877 | 4.9.15.7 Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 2878 | 4.9.16Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 2879 | A) Gate 3.00m wide |
| 2880 | 4.9.17 Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 2881 | A) Gate 3.00m wide |
| 2882 | 4.9.18 supply and filling the transformer yard with 40mm HBG metal m/c |
| 2883 | CAP BILL NO.4.10.Construction of Pump House at Clear water sump at Peddagedda reservoir |
| 2884 | 4.10.1 Earthwork in excavation in all types of soils for pipeline trenchesfor water supply lines, Sewer lines, Storm Water drainage as per specification drawings and as directed by theEngineer Incharge andprotecting the walls and other structures etc., andbackfilling in trenches with excavated suitable materialand disposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., |
| 2885 | 4.10.2 Collection, Supplyand filling of stone dustfrom approved quarry and stacking at work site for premeasurements including cost and convenyance of all material, labour charges etc. |
| 2886 | 4.10.3 Plain Cement concrete (1:4:8) using 40 mm metal with concrete mixture. All work upto plinth level |
| 2887 | 4.10.4 Supply and placing of theM 25Grade Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and includingall operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including pumping, centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. |
| 2888 | a) For Foundation |
| 2889 | b) For Columns |
| 2890 | c) Plinth Beams |
| 2891 | d) Beams |
| 2892 | e) For Lintels |
| 2893 | f) For Sunshades |
| 2894 | 4.10.5 Supplying, Fitting & placingHYSD bar reinforcement including cutting, bending ,bindingshifting to site, tying tand placing in the position including cost of steel & binding wire as per drawing and technical specification etc. complete as per direction of the Engineer-in-Charge. |
| 2895 | 4.10.6 Brick Masonry in CM (1:6)Proportion with PSC using traditional size 23 x 11 x 7 cms 2nd class Bricksincluding cost and conveyance of all materials, Mixing of cement mortor and laying of bricks and mortor to specified thickness , curing ,all labour charges complete for finished item of work |
| 2896 | 4.10.6 11.5 cm wide Brick masonry for super-structure on ground floor in cm (1:3) using second class traditional size bricks including cost of all materials, seigniorage charges, labour and all operations for constructing half brick masonry, mixing cement mortar, curing etc., complete for finished item of work,including conveyance charges of materials. |
| 2897 | 4.10.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS inside (Internal Plastering) |
| 2898 | 4.10.8 Plastering with20 mm thick with cement mortor(1:6) Proportion16mm thick and top coat in CM (1:4) OPC, 4mm thick with Dubara sponze finishing including cost and conveyance of all materials to site, screening fine aggregate, mixing and laying , finishing , curing, all labour charges etc. complete |
| 2899 | 4.10.9 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS |
| 2900 | a) Ceiling |
| 2901 | 4.10.10 Providing and fixing of Openable Windows made of pre-painted steel (Basesteel as per IS 513 of 0.58 mm thick galvanized as per IS 277 with Zinc of 120GSM), primer coated with epoxy primer of 5-7 microns thick, finish paintedwith a polyester paint of 12-16 microns thick and back coated with 5-7micronsthick alkyd backer and section for outer frame of 48 x 50 mm, centre mullionof 48 x 50 mm, section for shutter of 48 x 25 mm and the fixed glass beadingsection should be 12 x 12 mm and the outer frame and mullions to haverebate for glazed shutter with a 20 mm provision for guard bars/grills and thesections cut to length metre joined with corner bracket, centre mullion fixedwith mullion cap, handle, stay, 2 nos. of stainless steel heavy duty pivot hingesprovided per shutter and windows fitted with 5 mm thick plain float glass withrubber gaskets including fixing the frames in concrete/masonry wall by meansof self expanding screws, Including 10mm Square guard bars with 6”(152.4mm) pitch etc., complete for finished item of work.Centre fixed both side openable shutter window 5’0”x4’0”(1524mm x1219.2mm). Outer frame section size of 72x50mm. Shutter frame section size of 48 x 25 mm. Mullion section size of 72x50mm. Fixed beading section size of 12 x 12 mm. |
| 2902 | 4.10.11 Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 2903 | 4.10.12 Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface to required smoothness and slopes and thread lining including cost of all materials like cement, metal, sand and water etc., complete,for finished item of work, |
| 2904 | 4.10.13 Painting to new walls with 2 coats of water proof cement paint of apporved brand and shade over a base coat of approved cement primer grade I making making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 912 |
| 2905 | 4.10.14 Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials,including conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work |
| 2906 | CAP BILL NO.4.11Construction of 300 KL RCC Raw water GLBR atPeddagadda Reservoir. |
| 2907 | 4.11.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width (RBR-FNDN-1) |
| 2908 | 4.11.2 LayingwithCC (1:4:8) For FoundationProportion using 40 mm graded (SS-5) HBG m/c metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position,curing for 21 days etc.complete - cum |
| 2909 | 4.11.3 Laying VCC in M 30Grade design mix using 20mm graded SS-5 HBG m/c metal , coarse and fine aggregates conforming to IS: 383, and OPCincluding cost and conveyance of all materials, machinery,all labour charges (including placing in positionexpansion, contraction, construction, longitudinal joints and corner reinforcement if any but excluding cost of joint filler, sealant and reinforcementand its fabrication ), centering, vibration, curing for 21 days and all incidental & operational chargesetc. complete conforming to standard specification 1 Cum |
| 2910 | a) Footings and base slab |
| 2911 | b) Side Wall300mm thick |
| 2912 | c) Columns |
| 2913 | d) Beams |
| 2914 | e) Roofslab 150mm thick |
| 2915 | C4.11.4 onstruction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. RBR-SPST-7 |
| 2916 | 4.11.5 Painting walls with snow cem paint of good quality of approved colour over primary coat of cement primer including cost, and conveyance of all materials to site, taxes using brushes and including all required materials , watering charges all labour charges, scoffolding charges, lifting chargesoperational charges etc., complete for finished item of work and as directed by the departmental officer in charge of the work. |
| 2917 | 4.11.6 Plastering 12mm thick with cement mortar CM (1:4) including cost and conveyanceof all materials to site and seignorage fee, screening and mixing, laying, scoffolding, liftingand watering, curing including all labour charges, hire and operational charges and all taxes etc., complete as per SS and as directed by the departmental officer in charge of the work for the following item of work for Ground Floor |
| 2918 | 4.11.7 Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges etc complete |
| 2919 | 4.11.8 Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for external walls |
| 2920 | 4.11.9 Suply of HYSD Fe 415 grade steel including cost and conveyance to site and labour charges including cutting, bending, binding, fabrication of reinforcementincluding cost of binding wire etc. complete for reinforcement- 1 kg |
| 2921 | 4.11.10 Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes. |
| 2922 | 4.11.11 Supplying & fixing of Manhole cover and frame |
| 2923 | 4.11.12Supply and fixing of Swan neck ventilator including fixing charges |
| 2924 | 4.11.13 Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. The rates mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) ( ex-works) Excluding Transportation and all Taxes. |
| 2925 | 4.11.14 Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4 includingElectrostatic powder coating both inside and outside etc complete |
| 2926 | a)300 mm dia Sluice Valve |
| 2927 | b)150 mm dia Sluice Valve |
| 2928 | A)Labour charges for lowering and keeping in position of C.I. Sluice valves, reflux valves and scour valves. |
| 2929 | a)300 mm dia Sluice Valve |
| 2930 | b)150 mm dia Sluice Valve |
| 2931 | 4.11.15 Jointing the CI/DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with waterwith a water lead upto 500m and testing to required pressure complete. |
| 2932 | a) 300 mm dia flanged joints |
| 2933 | b) 300mm dia near valves |
| 2934 | c)150mm diaflanged joints |
| 2935 | CAP BILL NO.4.12Construction of 200 KL RCC Clear water Sump near WTPPeddagadda Reservoir. |
| 2936 | 4.12.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width (RBR-FNDN-1) |
| 2937 | 4.12.2 LayingwithCC (1:4:8) For FoundationProportion using 40 mm graded (SS-5) HBG m/c metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position,curing for 21 days etc.complete - cum |
| 2938 | 4.12.3 Laying VCC in M 30Grade design mix using 20mm graded SS-5 HBG m/c metal , coarse and fine aggregates conforming to IS: 383, and OPCincluding cost and conveyance of all materials, machinery,all labour charges (including placing in positionexpansion, contraction, construction, longitudinal joints and corner reinforcement if any but excluding cost of joint filler, sealant and reinforcementand its fabrication ), centering, vibration, curing for 21 days and all incidental & operational chargesetc. complete conforming to standard specification 1 Cum |
| 2939 | a)Footings and base slab |
| 2940 | b) Side Wall300mm thick |
| 2941 | c) Columns |
| 2942 | d) Beams |
| 2943 | e) Roofslab 150mm thick |
| 2944 | 4.12.4Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. RBR-SPST-7 |
| 2945 | 4.12.5 Painting walls with snow cem paint of good quality of approved colour over primary coat of cement primer including cost, and conveyance of all materials to site, taxes using brushes and including all required materials , watering charges all labour charges, scoffolding charges, lifting chargesoperational charges etc., complete for finished item of work and as directed by the departmental officer in charge of the work. |
| 2946 | 4.12.6 Plastering 12mm thick with cement mortar CM (1:4) including cost and conveyanceof all materials to site and seignorage fee, screening and mixing, laying, scoffolding, liftingand watering, curing including all labour charges, hire and operational charges and all taxes etc., complete as per SS and as directed by the departmental officer in charge of the work for the following item of work |
| 2947 | 4.12.7Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges etc complete |
| 2948 | 4.12.8 Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for external walls |
| 2949 | 4.12.9 Suply of HYSD Fe 415 grade steel including cost and conveyance to site and labour charges including cutting, bending, binding, fabrication of reinforcementincluding cost of binding wire etc. complete for reinforcement- 1 kg |
| 2950 | 4.12.10 Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes. |
| 2951 | 4.12.11 Supplying & fixing of Manhole cover and frame |
| 2952 | 4.12.12 Supply and fixing of Swan neck ventilator including fixing charges |
| 2953 | 4.12.13 Supplying and fixing of mechanical water level indicator with chain pully arrangements to suit GLSR upto LWL from average ground level as directed by the departmental officers |
| 2954 | 4.12.14 Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000 having dimensions as per table. The rates mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/IS 9523/2000) ( ex-works) Excluding Transportation and all Taxes. |
| 2955 | 4.12.15 Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4 includingElectrostatic powder coating both inside and outside etc complete PN 1.6 |
| 2956 | a) 300 mm dia Sluice Valve PN 1.6 |
| 2957 | b) 150 mm dia Sluice Valve PN 1.6 |
| 2958 | Labour charges for lowering and keeping in position of C.I. Sluice valves, reflux valves and scour valves. |
| 2959 | a) 300 mm dia Sluice Valve PN 1.6 |
| 2960 | b) 150 mm dia Sluice Valve PN 1.6 |
| 2961 | 4.12.16 Jointing the CI/DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with waterwith a water lead upto 500m and testing to required pressure complete. |
| 2962 | a)300 mm dia flanged joints |
| 2963 | b) 300mm dia near valves |
| 2964 | c) 150mm diaflanged joints |
| 2965 | 4.13.Supply, delivery, laying, jointing and testing of DI K9 Pumping mains for the following |
| 2966 | 4.13.2 Cutting open bituminous tar road surface including depositingof excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25a (PH SSR). |
| 2967 | 4.13.3 Cutting open cement concrete road surface including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25b (PH SSR). |
| 2968 | 4.13.4 Cutting open water bound macadam road including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete - 1 cum SSR Sl.No.25c(PH SSR). |
| 2969 | 4.13.5 RBR - FNDN-1 - (i-B) - In ordinary soils, by Mechanical means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material, dressing of sides and bottom as per Technical Specification 304 MORTH and as directed by the departmental officer including protecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earth upto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 2970 | a)% of the EWE Quantity |
| 2971 | 4.13.6 BLD-CSTN-2-5 - (13): Earth work excavation in Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Manual Means-Upto 3 m depth |
| 2972 | a)% of the EWE Quantity |
| 2973 | 4.13.7 RBR - FNDN - 1 - (i-A) In ordinary soils, by Manual means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 2974 | a)% of the EWE Quantity |
| 2975 | 4.13.8 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width ordinary rock mechanical means |
| 2976 | a)% of the EWE Quantity |
| 2977 | 4.13.9 RBR-FNDN-1 - manual means : Earthwork excavation for structures in all types of soil as per drawing and technical specificationsincluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH. for Sumps,Thrust blocks, Chambers and Man Holes etc. by manual means.(bends and specials) |
| 2978 | a) for specials of450mm dia |
| 2979 | 4.13.11 Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9 suitable for push on joint (Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation and ST etc,. complete. but excluding CED. |
| 2980 | a) 200 |
| 2981 | b) 400 |
| 2982 | c) 450 |
| 2983 | 4.13.12 Providing stone crusher dust for filling to the pipe line trenches including cost and conveyance to the materials to the site for finished items of work etc.complete.For road crossings |
| 2984 | 4.13.13 PHE-LCIS-1: Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 2985 | a) 200 |
| 2986 | b) 400 |
| 2987 | c) 450 |
| 2988 | d)450 |
| 2989 | 4.13.14 PHE-JCIR-4: Jointing the, D.I. Pipes & fittings with Rubber Gasket, including the cost of the gasket, all sundries filling with water with a water lead upto 500 m and testing to required pressure etc., complete as per BIS No.3114/85). |
| 2990 | a) 200 |
| 2991 | b) 400 |
| 2992 | c) 450 |
| 2993 | d) 450 mm dia DI K9 pipe |
| 2994 | 4.13.15 Manufacture, supply and delivery of centrifugally cast (spun ) ductile iron fittings conforming to IS No. 9523/2000 having dimentions as per table. , zinc coated externally with inside mortor lining (with finishing as per class 13/IS 9523/2000 as per Code No 1 ) including transportation, taxes and duties etc. |
| 2995 | 4.13.16 Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. |
| 2996 | A) DI. D/F Sluice valves ofPN.16 class |
| 2997 | a)200mm dia Sluice Valves |
| 2998 | b)300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 2999 | B) IsolatedSluice valves for air valves |
| 3000 | a)100mm dia Sluice Valves |
| 3001 | 4.13.17 Manufacture, Supply and delivery ofDI D/F Swing Check Valves Slanted/Straight seated with metallic, corrosion proof and wear resistant seat faces resilient seat, Body and Disc of ductile cast iron GGG 40/SG Iron 420/12 or equivalent grade as per IS 3896(part2)-1985 and subsequent revisions. All the inside and outside of the body is to be coated with double coating of epoxy liquid.Drilled as per IS:1538.Specification and Dimensions as per I.S 5312 or equivalent codes. 300mm Dia |
| 3002 | a)300mm Dia |
| 3003 | 4.13.18 Manufacture, Supply and Delivery of DI Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 3004 | a) 200mm Dia |
| 3005 | 4.13.19 PHE-CISV-15 : Lowering, keeping in position and fixing D.I. sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 3006 | a) 200mm dia Sluice Valves |
| 3007 | b) 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 3008 | 4.13.20 PHE-JCIF-5-: Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 3009 | a) 200mm dia Sluice Valves |
| 3010 | b) 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 3011 | 4.13.21 Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12orequivalent gradeasperI.S.3896-part2-1985 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality.SEpoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. |
| 3012 | a)80 |
| 3013 | L4.13.22 abour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 3014 | 80mm |
| 3015 | 4.13.23 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.For up to 200mm dia Sluicevalves and forrevamping pipe lines |
| 3016 | For up to 200mm dia Sluicevalves and forrevamping pipe lines |
| 3017 | 4.13.24 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 3018 | for 250mmdia to 350 Sluice valves |
| 3019 | 4.13.25 PHE-CCIP-23: Cutting C.I./ DI / MS Pipes without water in mains where ever required (.Dia of pipes in mm.) |
| 3020 | a)200 |
| 3021 | b) 400 |
| 3022 | c) 450 |
| 3023 | 4.13.26 Manufacture, supply and delivery of Ductile Ironpipes and fittings (spls.) conforming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988 at site of work anywhere in AP.including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. |
| 3024 | CAP BILL No. 4.14Supply , delivery, laying , jointing and testing of DI K7 gravitymain from 300KL Proposed GLBR at Peddagedda Reservoir to Proposed and existing ELSRs |
| 3025 | 4.14.2 Cutting open bituminous tar road surface including depositingof excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25a (PH SSR). |
| 3026 | 4.14.3Cutting open cement concrete road surface including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25b (PH SSR). |
| 3027 | 4.14.4 Cutting open water bound macadam road including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete - 1 cum SSR Sl.No.25c(PH SSR). |
| 3028 | 4.14.5 RBR - FNDN-1 - (i-B) - In ordinary soils, by Mechanical means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material, dressing of sides and bottom as per Technical Specification 304 MORTH and as directed by the departmental officer including protecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earth upto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 3029 | a)% of the EWE Quantity |
| 3030 | 4.14.6 BLD-CSTN-2-5 - (13): Earth work excavation in Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth |
| 3031 | a)% of the EWE Quantity |
| 3032 | 4.14.7 RBR - FNDN - 1 - (i-A) In ordinary soils, by Manual means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 3033 | a)% of the EWE Quantity |
| 3034 | 4.14.8 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width ordinary rock mechanical means |
| 3035 | a)% of the EWE Quantity |
| 3036 | 4.14.9 Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K7 suitable for push on joint (Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation and ST etc,. complete. but excluding CED. |
| 3037 | a) 150 |
| 3038 | b) 200 |
| 3039 | c) 250 |
| 3040 | d) 300 |
| 3041 | e) 400 |
| 3042 | 4.14.10 Providing stone crusher dust for filling to the pipe line trenches including cost and conveyance to the materials to the site for finished items of work etc.complete.At road crossings. |
| 3043 | 400 mm dia DI K7 pipe |
| 3044 | 4.14.11 PHE-LCIS-1: Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 3045 | a) 150 |
| 3046 | b) 200 |
| 3047 | c) 250 |
| 3048 | d) 300 |
| 3049 | e) 400 |
| 3050 | 4.14.12 PHE-JCIR-4: Jointing the, D.I. Pipes & fittings with Rubber Gasket, including the cost of the gasket, all sundries filling with water with a water lead upto 500 m and testing to required pressure etc., complete as per BIS No.3114/85. |
| 3051 | a) 150 |
| 3052 | b) 200 |
| 3053 | c) 250 |
| 3054 | d) 300 |
| 3055 | e) 400 |
| 3056 | 4.14.13 Manufacture, supply and delivery of centrifugally cast (spun ) ductile iron fittings conforming to IS No. 9523/2000 having dimentions as per table. , zinc coated externally with inside mortor lining (with finishing as per class 13/IS 9523/2000 as per Code No 1 ) including transportation, taxes and duties etc. |
| 3057 | 4.14.14 Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. |
| 3058 | A)DI. D/F Sluice valves ofPN.16 class |
| 3059 | a)200mm dia Sluice Valves |
| 3060 | b) 250mm dia Sluice Valves |
| 3061 | c) 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 3062 | d) 350mm dia Sluice Valves for 500mm dia pipes |
| 3063 | B) IsolatedSluice valves for air valves |
| 3064 | a)150mm dia Sluice Valves |
| 3065 | 4.14.15 Manufacture, Supply and delivery ofDI D/F Swing Check Valves Slanted/Straight seated with metallic, corrosion proof and wear resistant seat faces resilient seat, Body and Disc of ductile cast iron GGG 40/SG Iron 420/12 or equivalent grade as per IS 3896(part2)-1985 and subsequent revisions. All the inside and outside of the body is to be coated with double coating of epoxy liquid.Drilled as per IS:1538.Specification and Dimensions as per I.S 5312 or equivalent codes. 300mm Dia |
| 3066 | 300mm Dia |
| 3067 | 4.14.16 Manufacture, Supply and Delivery of DI Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 3068 | 300mm dia |
| 3069 | 4.14.18 PHE-CISV-15 : Lowering, keeping in position and fixing D.I. sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 3070 | a)300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 3071 | b) 350mm dia Sluice Valves for 500mm dia pipes |
| 3072 | 4.14.19 PHE-JCIF-5-: Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 3073 | a)300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 3074 | b) 350mm dia Sluice Valves for 500mm dia pipes |
| 3075 | 4.14.20 Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12orequivalent gradeasperI.S.3896-part2-1985 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality.SEpoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. |
| 3076 | a)150 |
| 3077 | 4.14.21 Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 3078 | a)150 |
| 3079 | 4.14.22 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 3080 | a) for 250mmdia to 350 Sluice valves |
| 3081 | 4.14.24 Manufacture, supply and delivery of Ductile Ironpipes and fittings (spls.) conforming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988 at site of work anywhere in AP.including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. |
| 3082 | CAP BILL NO.4.15.Construction of 800 KL capacity ELSR with a staging of 15mts with VRCC M30 mix including inlet, out let and scour connections, valves and all fixturesforzone- IBat Gandhipark. |
| 3083 | 14.15.1Construction of 800 KL capacity ELSR forzone-IB areawith a staging of 15m with VRCC M30 mix including fixtures mentioned below |
| 3084 | GL-155.62 mLWL-170.62 m MWL -175.12 m1) The above rates are arrived with base rate of Cement Rs.3882/- per MT & SteelRs 31746/- per MT (Bo CE rates for the month of May 2017.)2) All concrete components shall be designed with M30 Design Mix proportion.3) For intermediate capacities proportional rates shall be adopted.4) The foundations shall be designed for Annular Raft Footings.The above rates are applicable for Elevated Level Services Reservoirs / OHSRs forSBC of 15 T/Sqm.a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% onbasic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by1.0% onbasic rate up to 20 T/Sqmc) For SBC below 10T/sqm , solid raft shall be provided and for solid raft the rateshall be increased by 10% on basic rate.5) For staging less than 15 m, the rate shall be decreased by Rs.0.05 paisa on basicrate per litre per every Meter decrease in staging.6) For staging above 15 m, the rate shall be increased by Rs.0.10 paisa on basic rateper litre per every Meter additional staging.7) The above rates shall be increased / decreased due to increase/decrease in thecost of cement by Basic rate x {(Rc-3882)/3882 } x 0.07Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.8) The above rates shall be increased / decreased due to increase/decrease in thecost of Steel by Basic rate x { (Rs-31746)/31746} x0.2Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate. |
| 3085 | 9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to innersurface of the Reservoir including roof.b)The rate inclusive of 2 coats of weather proof emulsion painting for externalsurfaces, lettering, all required fixtures, Pipes, Pipe specials, valves of DI material,Valve chambers etc., for pipe connections including cost of pipes, specials and valvesas per departmental designs and drawings.10) For tribal/Agency / Rural area, the above rates as arrived up to shall be increasedby 10%.11) The above rates adopted for a wind pressure up to \"250 kg/sqm\". For every 100kg/sqm decrease in wind pressure, the rate shall be decreased by 5%12)a) The Basic rate is adopted by considering the design for Seismic forces for Zone- IIonly of seismic zones.(b) The basic rates shall be increased by 15 % for Zone-III of seismic zones.13. The ELSR/OHSR shall be designed with minimum of two rows of columns forcapacities above 500 KL & up to 1000KL.14. The ELSR/OHSR shall be designed with minimum of three rows of columns forcapacities above 1000KL.15) The basic rate is inclusive of following Fixturesi) Pipe connections & Specials with D.I materials(a) All pipe connections for Inlet, Out let, Over Flow, Scour pipes shall be providedwith D/F DI material.(b) The Valves for above pipe connections also shall be of DI material of PN 16 dutyconfirming to the specification of SoR item No.28(c) All specials such as Bends, Tees, Reducers, Duck foot Bends, Bell mouths etc,. Shallbe of DI material. |
| 3086 | CAP BILL NO.4.16.Construction of 500 KL capacity ELSR with a staging of 15mts with VRCC M30 mix including inlet, out let and scour connections, valves and all fixturesforzone- IVat Kapu Boddavalasa |
| 3087 | 4.16.1 Construction of 500 KL capacity ELSR forzone-IV areawith a staging of 15m with VRCC M30 mix including fixtures mentioned below |
| 3088 | GL-168.30 mLWL-180.30 m MWL -187.80 m1) The above rates are arrived with base rate of Cement Rs.5000/- per MT & Steel for Rs36000/- per MT for the month of April 2016.2) All concrete components shall be designed with M30 Design Mix proportion.3) For intermediate capacities proportional rates shall be adopted.4) The foundations shall be designed for Annular Raft Footings.The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqm. |
| 3089 | a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be incresed by 2.50% on basic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate.c) For SBC below 10T/sqm , solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate.5) For staging less than 15 m, the rate shall be decreased by Rs.0.05 paise on basic rate per litre per every Meter decrease in staging.6) For staging above 15 m, the rate shall be increased by Rs.0.10 paise on basic rate per litre per every Meter additional staging.7) The above rates shall be increased / decreased due to increase/decrease in the cost of cement by Basic rate x (Rc-5000) x (0.07/5000)Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.8) The above rates shall be increased / decreased due to increase/decrease in the cost of Steel by Basic rate x (Rs-36000) x (0.02/36000) Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.9) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof. |
| 3090 | 10) The above rates are adopted for preparation of estimate for construction of ELSRs/OHSRs for finished work including 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, Pipes,Pipe specials, valves of DI material, Valve chambers etc., for pipe connections including cost of pipes, specials and valves as per departmental designs and drawings.11) The above rates adopted for a wind pressure upto \"350 kg/sq m\". For every 100 kg/sqm decrease in wind pressure, the rate shall be decreased by 5%12) For tribal/Agency / Rural area, the above rates as arrived upto shall be increased by 10%.13.The Basic rate is adopted by considering the design for Seismic forces for Zone-I & II only of seismic zones.(a) The basic rates shall be increased by 33 1/3 % for Zone-III of seismic zones.14. The ELSR/OHSR shall be designed with minimum of two rows of columns for capacities above 500 KL & upto 1000KL.15. The ELSR/OHSR shall be designed with minimum of three rows of columns for capacities above 1000KL.16) The basic rate is inclusive of following Fixturesi) Pipe connections & Specials with D.I materials(a) All pipe conections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DI material.(b) The Valves for above pipe connections also shall be of DI material of PN 16 conforming to the specification of SoR item No.28(c) All specials such as Bends,Tees, Reducers, Duckfoot Bends,Bell mouths etc,. shall be of DI material. |
| 3091 | II) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRsInlet Pipe - 300mm dia.Out let Pipe - 350mm diaOver Flow pipe - 350m diaScour Pipe - 200mm diab) For 800 KL to 1500 Kl ELSRsInlet Pipe - 400mm dia.Out let Pipe - 450mm diaOver Flow pipe - 450mdia Scour Pipe - 200mm diac) For above 1500 KL to 2500 Kl ELSRsInlet Pipe - 400mm dia.Out let Pipe - 500mm diaOver Flow pipe - 500m diaScour Pipe - 200mm dia(iii) Manhole Frames & Coversa) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min.of 150mm dia) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos.v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 Noviii)The staircase shall be enclosed with brick masonary walls on three side and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement.The Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia pipe & middle railing of 25mm dia and verticals with 40mm dia at an interval not more than of 1.00m c/c.xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No)xii) Lightening Arrestor with all its accessories complete including earthing,with relevant IS Codes - 1 No.xiii)Compound wall: Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall be minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM(1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8)prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Gound level, over a bed of CC(1:4:8)- 100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angulars of 25mm X 25mm X 4mm in \"Y\" shape to hieght of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauge shall be streched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4) prop on both sides of brick work. Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreased Note:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL shall be as follows.:i) 500 KL : 0.086%ii) 1000 KL : 0.047%iii) 1500 KL : 0.034%iv) 2000 KL : 0.026%v) 2500 KL : 0.022 %For intermediate capacities, interpolated percentages shall be adopted.xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 sqm with the following specification: RCC framed structure withconcrete grade not less than M20 design mix at the locations specified by the department at the time of execution with verandah, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases.MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides openable shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall provided. Septic tank for 5 users shall be provided. |
| 3092 | CAP BILL NO.4.17 Construction of StaffQuarters atELSRs |
| 3093 | 4.17.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenchunit 1.00 cumRBR-FNDN-1I-A |
| 3094 | 4.17.2 Filling in foundation trenches with stone dustas per drawing and technical specification Clause 305.3.9 MORD & 304 MORTHfor foundations of cc drains and pipe line trench RBR-FNDN-2(1) |
| 3095 | 4.17.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 3096 | 4.17.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 3097 | A) Column Footings |
| 3098 | B)Columns1.50-0.15-0.15-0.20-0.25 =0.75 + basement 0.75m+superstructure 3.35m=4.85m |
| 3099 | C) Plinth beam |
| 3100 | D)Lintle beamsWindows |
| 3101 | E)Roof Beams |
| 3102 | F)Roof slab0.125m thick with 0.30m extension all sides |
| 3103 | G)Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 3104 | H)Loft slab 0.075m thick kitchen |
| 3105 | 4.17. 5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 3106 | A)parapet wall (5.56*2+7.43*2 = 25.98) |
| 3107 | 4.17.6 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 3108 | A)1st floor |
| 3109 | i) parapet wall |
| 3110 | 4.17.7 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 3111 | A)For ceiling slab area |
| 3112 | 4.17.8 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 3113 | 4.17.8.1 Outside plastering area |
| 3114 | 4.17.9 Supply delivery and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 3115 | a)50 mm thick |
| 3116 | 4.17.10 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 3117 | a) Door -D - 1.20X2.10 m |
| 3118 | b) doorsD1 -1.0X2.10m |
| 3119 | 4.17.11 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 3120 | a)windows 1.20x1.20 |
| 3121 | 4.17.12 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 3122 | a) Toilet door D2 |
| 3123 | 4.17.13 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 3124 | a) Toilet door D2 |
| 3125 | 4.17.14 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 3126 | 4.17.15 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 3127 | 4.17.16 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 3128 | a)windows |
| 3129 | 4.17.17 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 3130 | b) Windows grill |
| 3131 | 4.17.18 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 3132 | 4.17.19 Providing Electrification |
| 3133 | 4.17.19(a) Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour charges |
| 3134 | 4.17.19(b) Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges |
| 3135 | a) Hall , Bed Room , Kitchen, Toilet |
| 3136 | 4.17.19(c) Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 3137 | 4.17.19(d) Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 3138 | a) Hall , Bed Room , Kitchen, Toilet |
| 3139 | 4.17.19 (e ) supply andrun of 2 of36/0.3 mm. (2.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 3140 | 4.17.19(f) supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 3141 | 4.17.19(g) supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 3142 | 4.17.19(h) Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 3143 | 4.17.19(i) Supply and fixing SPN Distribution board with IP-30 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete |
| 3144 | 4.17.19(j) Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 3145 | a) Hall , Bed Room , Kitchen |
| 3146 | 4.17.19(k) Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 3147 | b) Hall , Bed Room , Kitchen |
| 3148 | 4.17.19(l) Supply of 1 x 36/40W Box type tube light luminaire powder coated CRCA sheet steel housing with Electronic Ballast Chokes and all standard accessoriesof makes Wipro / G.E. / Phillips / Crompton / Bajaj. |
| 3149 | 4.17.20Sanitary and water supply |
| 3150 | A) Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 3151 | a) 2000 lts capacity |
| 3152 | B) Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 3153 | a) Fortoilets |
| 3154 | C) Supplying & Fixing low down porcelain flushing tank 10 Lit Capacity Hindustan Sanitary ware/ parry/ Neycer with internal components |
| 3155 | a)Fortoilets |
| 3156 | D) Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 3157 | a) Fortoilets |
| 3158 | E) Supply of 110 mm dia 3 M single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 3159 | a) from toilets to septic tank |
| 3160 | F) Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 3161 | G) Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 3162 | H) Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 3163 | a) 110 mm dia |
| 3164 | I) Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 3165 | J) S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 3166 | a) 25 mm dia nominal bore -from tank to jn forof individual lines |
| 3167 | b) 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 3168 | c) 15 mm dia nominal bore -for internal |
| 3169 | K) S&F of GI &GM fittings |
| 3170 | a) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 3171 | b) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 3172 | c) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 3173 | d) S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 3174 | L) S& F GI union Ist Quality |
| 3175 | i) 12.70mm |
| 3176 | ii) 19.05mm |
| 3177 | iii) 25.40mm |
| 3178 | 4.17.21 For septic Tank |
| 3179 | A) Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD.Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth |
| 3180 | B) Filling with stone dustin foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 3181 | C) Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 3182 | D) Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 3183 | E) Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 3184 | F) RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 3185 | a) For septic Tank 0.15 m thick |
| 3186 | G) Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 3187 | a) For septic Tank @120 kgs/cum |
| 3188 | CAP BILL N0. 4.18.Supply distrubution and fixing, installation of Flowmeters, Motorised Valves, Level Indicators including Supervisory Control and Data Acuasation System (SCADA) for controlling and monitoring of the bulk water supply pipelines for Salur Raw Water WELL CUM Pump House at Peddagadda Reservoir, CW Collection WELL CUM Pump House, CWS 200 KL At Head Water Works, Salur WTP (7MLD), Gandhi Park (Zone-1A, 800 KL, EX. ELSR), Gandhi Park (Zone-1B, 800 KL, Prop. ELSR), Majjulapeta (Zone-2, 500 KL, ELSR), Oriya Panda Veedhi (Zone-3, 800 KL, ELSR), Kapu Bodavalasa (Zone-4, 500 KL, ELSR). |
| 3189 | 4.18.1 Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 3190 | a) For Raw Water Pumping Station as per the above specificationb) For Clear Water Pumping Station as per the above specificationc) For Clear Water Pumping Station as per the above specification |
| 3191 | 4.18.2 Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3192 | a) For Raw Water Pumping Station as per the above specificationb) For Clear Water Pumping Station as per the above specificationc) For Clear Water Pumping Station as per the above specification |
| 3193 | 4.18.3 Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facilitycomplete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties |
| 3194 | a) For Clear Water Pumping Station as per the above specification |
| 3195 | 4.18.4 Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer |
| 3196 | a) DN 150 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification |
| 3197 | 4.18.5 Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 3198 | 350MM Dia Above Specification.a) outlet of Raw Water Pumping Station at Pedagedda reserviorb) Outlet of Clear Water Pumping main at Pumping stationc) Outlet of Clear Water Pumping main at Pumping stationd) Outlet of 300KL Balanced GLBRat Pumping station |
| 3199 | 4.18.6 Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 3200 | a) Raw Water Inlet of Water Treatment plantb) Clear Water outlet of Water Treatment plant |
| 3201 | 4.18.7 Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 3202 | a) Raw Water Inlet of Water Treatment plantb) Clear Water outlet of Water Treatment plant |
| 3203 | 4.18.8 Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 3204 | a) Raw Water Inlet of Water Treatment plantb) Clear Water outlet of Water Treatment plant |
| 3205 | 4.18.9 Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 3206 | a) Clear Water outlet of Water Treatment plant |
| 3207 | 4.18.10 Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3208 | a) Raw Water Inlet of Water Treatment plantb) Clear Water outlet of Water Treatment plant |
| 3209 | 4.18.11 Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 3210 | a) Raw Water inlet and clear water outlet at WTP |
| 3211 | 4.18.12 Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 3212 | a) Raw Water Inlet of Water Treatment plantb) Clear Water outlet of Water Treatment plant |
| 3213 | 4.18.13supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 3214 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3215 | 4.18.14 Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 3216 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3217 | Su4.18.15 pply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 3218 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3219 | 4.18.16 Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3220 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3221 | 4.18.17 Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3222 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3223 | 4.18.18 Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 3224 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3225 | 4.18.19 Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 3226 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3227 | 4.18.20 Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3228 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3229 | 4.18.21 Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 3230 | A)150MM Dia Above Specification.a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3231 | 4.18.22 Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3232 | a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3233 | 4.18.23 Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3234 | a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3235 | 4.18.24 Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3236 | a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3237 | 4.18.25 Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3238 | a) Inlet of 500 KL Proposed ELSR at Kapu boddavalasab) Inlet of 800 KL Existing ELSR at Panda veedi c) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Bd) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Ae) Inlet of 500 KL Existing ELSR at Majjualapetaf) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3239 | A) 24 x 7 Water Supply ::DMA Management :: |
| 3240 | 4.18.26supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. (200MM Dia Above Specification.) |
| 3241 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3242 | 4.18.27 Supply and deliveryof Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.(200MM Dia Above Specification.) |
| 3243 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3244 | 4.18.28 Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer(200MM Dia Above Specification.) |
| 3245 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3246 | 4.18.29 Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.(200MM Dia Above Specification.) |
| 3247 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3248 | 4.18.30Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 3249 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3250 | 4.18.31 Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 3251 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3252 | 4.18.32 Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3253 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3254 | 4.18.33 Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3255 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3256 | 4.18.34 Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3257 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3258 | 4.18.35 Providing, Installing and satisfactory field testing of Self Powered Presuure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.(Pressure points at Highest Point, Lowest Point & Furthest Point) |
| 3259 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi parkB) Under 500 KL ELSR at Kapu Boddavalasa |
| 3260 | 4.18.36 Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 3261 | A) Inlet of DMA-1,2&3 under 800 KL ELSR at Gandhi park |
| 3262 | 4.18.37 Local SCADA Control Sation: |
| 3263 | A)Establishment of Local SCADA station at Saluru Municipality with the above specifications. |
| 3264 | B) Establishment of Local SCADA station at Saluru Municipality with the above specifications. |
| 3265 | CAP Bill No 4.19 AMR Water meters |
| 3266 | 4.19.1 Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-A. |
| 3267 | A) DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area |
| 3268 | 4.19.2 Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoTin every 24 Hours without fail through the provider registered inDOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication)The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warrantiesand submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-B |
| 3269 | A)Inlet of DMA-1, 2 & 3under 00 KL ELSR at Gandhi park |
| 3270 | 4.19.3 Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer. |
| 3271 | CAP BILL NO.4.20.Construcion of Room for SCADA Room 8.00 x 12.00 Size. |
| 3272 | 4.20.1 Earthwork excavation by Manuallyin all types of soilsfor structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification |
| 3273 | 4.20.2 Supply and filling with Stone dust complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification |
| 3274 | 4.20.3 Laying Cement concrete (1:4:8)using 40mm nominal size HBG metal M/C including cost and conveyance of all materials from approved quarry, machine mixing, vibrating, laying, levelling, ramming, curing and labour charges etc., complete. |
| 3275 | 4.20.4 Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification |
| 3276 | 4.20.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum |
| 3277 | a) Footings |
| 3278 | b) Pedastals around Columns |
| 3279 | c) Columns Up to plinth |
| 3280 | d) Plinth Beams |
| 3281 | e) Columns |
| 3282 | f) Beams |
| 3283 | g) Lintels |
| 3284 | h) Sunshades avg 75 mm thick |
| 3285 | i) Staircase 0.15 mts thick |
| 3286 | j) RCC Slab 150mm thick |
| 3287 | 4.20.5 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT)steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification |
| 3288 | 4.20.6 Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of workand as per Technical Specification |
| 3289 | 4.20.7 Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification- Outside |
| 3290 | 4.20.8 Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification.- Inside |
| 3291 | 4.20.9 Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification- Ceiling |
| 3292 | 4.20.10Flooring with ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials as per the technical specification |
| 3293 | 4.20.11Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification-out siide |
| 3294 | 4.20.12 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification-Inside |
| 3295 | 4.20.13 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification- Ceiling |
| 3296 | 4.20.14 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 3297 | 4.20.15 Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6\" pitch complete for finished item of work as per the technical speciification Windows: Double shutter 3\"-0\" x 4\"-0\" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm. |
| 3298 | 4.20.16 Supply of ...............INVERTER Model Cool type split AC unit with highwall mounted Single Split indoor unit and outdoor condensing unitHermetically sealed compressor suitable for operation on 230V, 50Hz,1Phase AC supply capable of performing Heat cool dehumidifying aircirculating and filtering with cooling and condensing units with 3 mts ofcopper piping, insulation kit and 4 mts of 4 core copper flexible chordwith cordless remote control etc., dual barrier coating in order to protectcoil form oxidation with copper condenser2.0TR, 5 Star capable of delivering not lessthan 21600 BTU/hr and above with operating onrefrigerant R-410A / R-32Makes: As per list of recommended brands ascategory II. |
| 3299 | CAPBill No:4.21 Laying ofHDPE pipe lines of 315 mm OD , 280mm OD, 250 mm OD, 225 mm OD, 200mm OD, 180mm OD, 160mm OD, 140mm OD,125mm OD & 110mm OD of Grade PE-100 PN 6.0 Kg/cm2forproviding 24 X 7 distribution system for a length of 39.12 Km including road restoration,DI sluice valves, DI air valves,valve chambers etc for inZone I to IV. |
| 3300 | 4.21.2 Cutting open BT road surface as well as asphalt concrete including water bound macadamand stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 3301 | 4.21.3 Cutting open C.C. road surface including stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 3302 | 4.21.4 Cutting open water bound macadam road including soiling for pipe line trench work. as directed by the departmental officers. |
| 3303 | 4.21.5 RBR-FNDN-1- (i-B) - In ordinary soils, by Mechanical meansEarthworkexcavationin all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 3304 | 4.21.5.1 % of the EWE Quantity |
| 3305 | 4.21.6 BLD-CSTN-2-5 - (13): Earth work excavation for foundations and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth |
| 3306 | 4.21.6.1% of the EWE Quantity |
| 3307 | 4.21.7 RBR-FNDN-1- (i-A) In ordinary soils, by Manual meansEarthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 3308 | 4.21.7.1 % of the EWE Quantity |
| 3309 | 4.21.8 RBR-FNDN-1- (iv) - In hard rockblasting prohibited:Excavation in Hard rock (blasting prohibited) Upto 3 m depth including 1.5 m depth in hard rock : Earthwork excavation in hard rock such as sheet rock and boulders in habitant areas where conventional blasting can not be donefor pipe line trenches, including all incidental and operational charges etc., complete. |
| 3310 | 4.21.8.1 % of the EWE Quantity |
| 3311 | 4.21.9 Manufacture, supply, delivery of HDPE pipes conforming to IS 4984 - 1995 includingtransportation to any where in AP, Excise duty, sales tax etc., complete ( Supply upto 90mm dia in coil & above 90mm dia strightin length in 6M) (6 Kg/Sq Cm) |
| 3312 | A) 110 mm dia HDPE 6Kg/Cm2 pipe |
| 3313 | B) 160 mm dia HDPE 6Kg/Cm2 pipe |
| 3314 | C) 200 mm dia HDPE 6Kg/Cm2 pipe |
| 3315 | D) 250 mm dia HDPE 6Kg/Cm2 pipe |
| 3316 | E) 315 mm dia HDPE 6Kg/Cm2 pipe |
| 3317 | 4.21.10 Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete as per S.S |
| 3318 | A) 110 mm dia HDPE 6Kg/Cm2 pipe |
| 3319 | B) 160 mm dia HDPE 6Kg/Cm2 pipe |
| 3320 | C) 200 mm dia HDPE 6Kg/Cm2 pipe |
| 3321 | D) 250 mm dia HDPE 6Kg/Cm2 pipe |
| 3322 | E) 315 mm dia HDPE 6Kg/Cm2 pipe |
| 3323 | 4.21.11 Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to any where in AP, Central excise duty, sale taxetc., complete |
| 3324 | i) Bends for |
| 3325 | A) 110 mm dia HDPE 6Kg/Cm2 pipe |
| 3326 | B) 160 mm dia HDPE 6Kg/Cm2 pipe |
| 3327 | C) 200 mm dia HDPE 6Kg/Cm2 pipe |
| 3328 | D) 250 mm dia HDPE 6Kg/Cm2 pipe |
| 3329 | E) 315 mm dia HDPE 6Kg/Cm2 pipe |
| 3330 | ii) End caps for |
| 3331 | A) 110 mm dia HDPE 6Kg/Cm2 pipe |
| 3332 | B) 160 mm dia HDPE 6Kg/Cm2 pipe |
| 3333 | C) 200 mm dia HDPE 6Kg/Cm2 pipe |
| 3334 | D) 250 mm dia HDPE 6Kg/Cm2 pipe |
| 3335 | E) 315 mm dia HDPE 6Kg/Cm2 pipe |
| 3336 | iii) Long neck pipe ends for |
| 3337 | A) 110 mm dia HDPE 6Kg/Cm2 pipe |
| 3338 | B) 160 mm dia HDPE 6Kg/Cm2 pipe |
| 3339 | C) 200 mm dia HDPE 6Kg/Cm2 pipe |
| 3340 | D) 250 mm dia HDPE 6Kg/Cm2 pipe |
| 3341 | E) 315 mm dia HDPE 6Kg/Cm2 pipe |
| 3342 | iv) MS flanges to suit HDPE pipes for |
| 3343 | A) 110 mm dia HDPE 6Kg/Cm2 pipe |
| 3344 | B) 160 mm dia HDPE 6Kg/Cm2 pipe |
| 3345 | C) 200 mm dia HDPE 6Kg/Cm2 pipe |
| 3346 | D) 250 mm dia HDPE 6Kg/Cm2 pipe |
| 3347 | E) 315 mm dia HDPE 6Kg/Cm2 pipe |
| 3348 | v) Tees for |
| 3349 | A) 110 mm dia HDPE 6Kg/Cm2 pipe |
| 3350 | B) 160 mm dia HDPE 6Kg/Cm2 pipe |
| 3351 | C) 200 mm dia HDPE 6Kg/Cm2 pipe |
| 3352 | D) 250 mm dia HDPE 6Kg/Cm2 pipe |
| 3353 | E) 315 mm dia HDPE 6Kg/Cm2 pipe |
| 3354 | 4.21.12 Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K7suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportationand CED and ST etc,. complete. |
| 3355 | a) 300MM DIA DI K7 |
| 3356 | b) 350 mm dia DI K7 |
| 3357 | c) 400 mm dia DI K7 |
| 3358 | 4.21.13 PHE-LCIS-1: Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 3359 | a) 300MM DIA DI K7 |
| 3360 | b) 350 mm dia DI K7 |
| 3361 | c) 400 mm dia DI K7 |
| 3362 | 4.21.14 PHE-JCIR-4: Jointing the C.I. Pipes, D.I. Pipes & fittings with Rubber Gasket includingcost of the gasket, all sundries filling with water with a water lead upto 500 m and testing to required pressure etc., complete as per BIS No.3114/85. |
| 3363 | a) 300MM DIA DI K7 |
| 3364 | b) 350 mm dia DI K7 |
| 3365 | c) 400 mm dia DI K7 |
| 3366 | 4.21.15 Manufacture, supply and delivery of centrifugally cast (spun ) ductile iron fittings conforming to IS No. 9523/2000 having dimentions as per table. , zinc coated externally with inside mortor lining (with finishing as per class 13/IS 9523/2000 as per Code No 1 ) including transportation, taxes and duties etc. |
| 3367 | 4.21.16 Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. |
| 3368 | A) DI. D/F Sluice valves ofPN.16 class |
| 3369 | a) 100mm dia Sluice Valves |
| 3370 | b) 150mm dia Sluice Valves |
| 3371 | c) 200mm dia Sluice Valves |
| 3372 | d) 250mm dia Sluice Valves |
| 3373 | e) 300mm dia Sluice Valves |
| 3374 | f) 350mm dia Sluice Valves |
| 3375 | g) 400mm dia Sluice Valves |
| 3376 | h) 100mm dia Scour valves |
| 3377 | i) 150mm dia Scour valves |
| 3378 | j) 200mm dia Scour valves |
| 3379 | 4.21.17 PHE-CISV-15 : Lowering, keeping in position and fixingD.I. sluice valves (with cap / with hand wheel & reflex valves)includingcost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 3380 | a) 100mm dia Sluice Valves |
| 3381 | b) 150mm dia Sluice Valves |
| 3382 | c) 200mm dia Sluice Valves |
| 3383 | d) 250mm dia Sluice Valves |
| 3384 | e) 300mm dia Sluice Valves |
| 3385 | f) 350mm dia Sluice Valves |
| 3386 | g) 400mm dia Sluice Valves |
| 3387 | 4.21.18 Manufacture, Supply and Delivery of DI Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 3388 | a) 100mm Dia |
| 3389 | b) 150mm Dia |
| 3390 | c) 200mm Dia |
| 3391 | d) 250mm Dia |
| 3392 | e) 300mm dia |
| 3393 | 4.21.19 Manufacture, Supply and Delivery of MS Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 3394 | a) 350mm dia |
| 3395 | b) 400mm Dia |
| 3396 | 4.21.20 PHE-JCIF-5-: Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 3397 | a) 350mm dia Sluice Valves |
| 3398 | b) 400mm dia Sluice Valves |
| 3399 | 4.21.21 Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12orequivalent gradeasperI.S.3896-part2-1985 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality.SEpoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. |
| 3400 | a) 80 mm dia air valve |
| 3401 | 4.21.22 Labour charges for fixing Kinetic Air ValvesDouble Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 3402 | a) 80 mm dia air valve |
| 3403 | 4.21.23 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 3404 | a) For up to 200mm dia Sluicevalves and forrevamping pipe lines |
| 3405 | 4.21.24 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 3406 | a) for 250mmdia to 350 Sluice valves |
| 3407 | b) for 400mmdia to 600 Sluice valves |
| 3408 | 4.21.25 Carting away thesurplus excavatedmaterial i.e.Earthand Rubble from the site to a suitabledistanceof about 10.00 Kmincluding loading, unloading , conveyance charges and dumping the carted material at the contractors cost, labour charges, all leads & lifts and other incidental and operational charges etc., complete. |
| 3409 | a) 90% of rock Qty |
| 3410 | 4.21.26 PHE-CCIP-23: Cutting C.I./ DI / MS Pipes without water in mains where ever required (.Dia of pipes in mm.) |
| 3411 | a) 350 mm dia DI K7 |
| 3412 | b) 400 mm dia DI K7 |
| 3413 | 4.21.27 Manufacture, supply and delivery of DuctileIron pipes and fittings (spls.) conforming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988 at site of work anywhere in A.P.including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. |
| 3414 | 4.21.28 Collection, supply and filling of stone dust/quarry spall to work site including cost and conveyance of all materials and all labour charges for flling etc., complete. |
| 3415 | 4.21.29 Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 3416 | CAP Bill No : 4.22.Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100Pipe including lowering, laying and jointing including earth work excavation and refilling the pipe line trench after layingthe pipe lineand including cost of 15mm dia meter of BIS standard and construction of meterchamberetc complete and transfering of house service connection as directed by departmental officer for finished item of work. |
| 3417 | 4.22.1 Providing 15 mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle, Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80, Compression Elbows, MDPE PE100 Pipe including lowering, laying and jointing including earth work excavation, UPVC Casingpipe with Two Calmps for drain crossings,Drilling of Holes for RR Masonary and CC Walls, Boring&Tunneling below CC & BT Roads, saw cutting of groves in CC Roads and refilling the pipe line trench after layingthe pipe lineand including cost of 15mm dia meter of BIS standardetc complete as directed by departmental officer for finished item of work.( CC Roads and BT Roads should not be distrubed).Provide 4.00 mtr length MDPE pipe for House side conncetions and 7.00 mts length MDPE pipe at opposite side to be laid. |
| 3418 | 4.22.3 Connection at House Side |
| 3419 | 4.22.5 With CC&BT Road Cutting for Pits |
| 3420 | 4.22.6 in Earthen Roads |
| 3421 | CAP Bill No. 4.23 Hiring for 2 Nos. Vehicles for 84 Months during execution period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc., |
| 3422 | 4.23.1 Hiring for 2 Nos. Vehicles for 84 Months during execution period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc., |
| 3423 | CAP Bill N. 4.24 EMP |
| 3424 | 4.24.1 Monitoring Costs : Construction Phase(Two years) |
| 3425 | A)Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 3426 | B)Noiselevel(5 Monitoringstation)onceinamonthforthree seasonsduring the constructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 3427 | C) Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 3428 | OP Bill N. 4.1 Source - Operation & Maintancecost for seven years including two years defect liablity period but excluding power charges |
| 3429 | 4.1.1 For 1st Year |
| 3430 | I) Personal required for operating Intake/Offtake well/Pump houses |
| 3431 | a) Operator |
| 3432 | b) Fitter/Helper |
| 3433 | c) Watch man |
| 3434 | II) Personal required at operating Water treatment plants & Sump |
| 3435 | a) Operator |
| 3436 | b) Fitter/Helper |
| 3437 | c) Electrician /Mechanic |
| 3438 | d) Watch man |
| 3439 | III) Personal required at operating Service reservoirs |
| 3440 | a) Watch man |
| 3441 | IV) Personal required at operating distribution system |
| 3442 | a) Watch man |
| 3443 | 4.1.2Total Amount for remaining 6 years |
| 3444 | 4.1.3 Consumables |
| 3445 | A) Chlorine gas for Disinfection @ 3 mg/Lt |
| 3446 | i) Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines. |
| 3447 | B) Alumino -Ferric (Alum) @ 20 mg/Lt |
| 3448 | i) Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit |
| 3449 | 4.1.4 Total Amount for Consumables for remaing 6 years |
| 3450 | 4.1.5 Repairs to pumpsets & Water pipe lines(2 years after execution period) |
| 3451 | i) Replacement of bearings of pumpsets |
| 3452 | ii) Replacement of sleeves |
| 3453 | iii) Raw Water Motors |
| 3454 | iv) Clear Water Motors |
| 3455 | v))Replacement of glands of sluice valves |
| 3456 | vi) Replacements of balls of Air valves |
| 3457 | vii) Greease |
| 3458 | viii) Gland Packing |
| 3459 | 4.1.6 Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete |
| 3460 | a) 315 mm HDPE Pipes |
| 3461 | b) 250 mm HDPE Pipes |
| 3462 | c) 200 mm HDPE Pipes |
| 3463 | d) 160 mm HDPE Pipes |
| 3464 | e) 110 mm HDPE Pipes |
| 3465 | 4.1.7 Total Amount for Repairs for next 4 years |
| 3466 | OP Bill N. 4.2Package - II. Monitoring costs : Operation Phase Implementation of Environment Management Plan (EMP). |
| 3467 | 4.2.2 Monitoring Costs : Operation Phase ( One year) |
| 3468 | A) Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 3469 | B) Noiselevel(5Monitoringstation)onceinamonthforthree seasonsduring the constructionperiodat intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 3470 | C) Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 3471 | D)Compensatory plantation andthree years maintenance (Compensatory afforestation ratio is 1:5) |
| 3472 | E) Sprinkling of wateronce in a day fortwo years (excluding rainy days):500 days @ Rs.1000/trip |
| 3473 | OP Bill N. 4.3Local SCADA at ULB |
| 3474 | 4.3.1 To asist to attend the service calls by the seniour service engineer |
| 3475 | 4.3.2 With assistance of the DBA, preparation of daily reports, monthly billing, correspondence with consumers and also co-ordinate with the GVMC Officials for obtaining of required information when ever asks. |
| 3476 | 4.3.3 To assist the entire team, dispatches and also maintain SCADA station clean and neat |
| 3477 | 4.3.4 MA on Labour : |
| 3478 | 4.3.5 CP : |
| 3479 | 4.3.6 Hiring of vehicle (4 wheeler)Rate as per G.O.MS.No.87Dated 01-06-2017.(To attend service calls and break down on 24 x 7) |
| 3480 | 4.3.7 Replacement of necessary servicable materials(Reagents) for Chlorine Analysers*Each Reagent bottle willwork for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minutes. |
| 3481 | a) Clear Water outlet of Water Treatment plantb) Inlet of 500 KL Proposed ELSR at Kapu boddavalasac) Inlet of 800 KL Existing ELSR at Panda veedi d) Inlet of 800 KL Proposed ELSR at Gandhi park - 1Be) Inlet-1 of 800 KL Existing ELSR at Gandhi park - 1Af) Inlet of 500 KL Existing ELSR at Majjualapetag) Inlet-2 of 800 KL Existing ELSR at Gandhi park - 1A |
| 3482 | 4.3.8 Replacement of necessary tranducers for PH analysers |
| 3483 | a) Raw Water Inlet of Water Treatment plantb) Clear Water outlet of Water Treatment plant |
| 3484 | 4.3.9 Replacement of necessary tranducers for Turbidity analysers |
| 3485 | a) Raw Water Inlet of Water Treatment plantb) Clear Water outlet of Water Treatment plant |
| 3486 | 4.3.10 BSNL Charges for static IP |
| 3487 | 4.3.11 GPRS Connections |
| 3488 | 4.3.12 Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
| 3489 | OP Bill N. 4.4 Central SCADA for ULB |
| 3490 | 4.4.1 ESTABLISHMENT : |
| 3491 | A) To monitor all issues related to both operation & service |
| 3492 | B) To monitor all meters location through SCADA station and give feedback to the service engineers. |
| 3493 | C) With assistance of the DBA, preparation of daily reports, monthly billing, correspondence with consumers and also co-ordinate with the Officials for obtaining of required information when ever asks. |
| 3494 | D) To assist the entire team, dispatches and also maintain SCADA station clean and neat |
| 3495 | 4.4.2 MAINTAINANCE OF LOCAL CONTROL STATION : |
| 3496 | A) Interconnection for Data receive station from all Local Contol RTU panels. |
| 3497 | B) Data storage and reporting system for view through WEB and Mobile networks |
| 3498 | C) for day to day Operations & Reporting |
| 3499 | 5. Nellimarla NP |
| 3500 | Construction of 4.0 Mts diaInfiltration well cum Pump house in the bed of Champavathi River near Existing Infiltration well at Jarajaupeta. (Balance work) |
| 3501 | Providing plugging of well with 40mm HBG metal including cost and conveyence of all materials and labour charge |
| 3502 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete with all de-lift charges but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)( For Pump House Side Wall 230mm thick) |
| 3503 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Centre Beam) |
| 3504 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Floor Slab) |
| 3505 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Lintel Beams Alround) |
| 3506 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Roof Beams) |
| 3507 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Roof slab 0.15m Thick) |
| 3508 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402 (For Sunshade of 0.60mts wide and thickness of .075mts at fixed end and 0.05mts.at free end) |
| 3509 | Supply and fixing of50 mm thick pre-cast Cement Jali of approved design including cost and conveyance to work spot and all labour charges for fixing in position etc.complete as per S.S |
| 3510 | Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work BLD-CSTN-8-25 |
| 3511 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. (Inside) |
| 3512 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. (Outside) |
| 3513 | Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 3514 | Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 3515 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-30 (For Pump house1.35x1.20m size) |
| 3516 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works, including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work. |
| 3517 | Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface to required smoothness and slopes and thread lining including cost of all materials like cement, metal, sand and water etc., complete, including seigniorage charges, etc., complete for finished item of work, but excluding the cost of conveyance of all materials.BLD-CSTN-7-13 |
| 3518 | Fabrication, supply and transportation of all sizes swaged poles up to site confirming to IS 2713 / 1980 specifications. The pole should be painted with primary coat of red oxide andblackbituminouspaintuptogroundlevelwithbase plate,includingcostofallmaterialsetc.,complete.(Rate per K. G) |
| 3519 | Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 3520 | Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges |
| 3521 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 3522 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 3523 | supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 3524 | supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 3525 | supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 3526 | Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 3527 | Supply and fixing SPN Distribution board with IP-30 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete. |
| 3528 | Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 3529 | Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 3530 | Supply of 9\" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT |
| 3531 | Supply and fixing of 20W, 2400 lumens, T8 not lessthan 1100 mm length LED retrofit tube light withaluminum anodized body, input voltage AC 220 -260 Volts, having luminous efficacy >=100 lumens/watt, with PF>0.9, surge protection: 2KV, THD<10%,with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part5/ Sec 1), 2012, complete with earth connection andnot less than two years warranty. Makes: As per listof recommended brands as category I. |
| 3532 | Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 3533 | Construction of 4.0 Mts diaInfiltration well cum Pump house in the bed of Champavathi River near the Railway Bridge. (Balance work) |
| 3534 | Providing plugging of well with 40mm HBG metal including cost and conveyence of all materials and labour charge |
| 3535 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete with all de-lift charges but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (PumpHouse Sidewalls) |
| 3536 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Centre Beam) |
| 3537 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Floor Slab) |
| 3538 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Lintel Beams Alround) |
| 3539 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Roof Beams) |
| 3540 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Roof slab 0.15m Thick) |
| 3541 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402 (For Sunshade of 0.60mts wide and thickness of .075mts at fixed end and 0.05mts.at free end) |
| 3542 | Supply and fixing of50 mm thick pre-cast Cement Jali of approved design including cost and conveyance to work spot and all labour charges for fixing in position etc.complete as per S.S |
| 3543 | Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work BLD-CSTN-8-25 |
| 3544 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. (Inside) |
| 3545 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. (Outside) |
| 3546 | Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 3547 | Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 3548 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-30 (For Pump house1.35x1.20m size) |
| 3549 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works, including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work. |
| 3550 | Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface to required smoothness and slopes and thread lining including cost of all materials like cement, metal, sand and water etc., complete, including seigniorage charges, etc., complete for finished item of work, but excluding the cost of conveyance of all materials.BLD-CSTN-7-13 |
| 3551 | Fabrication, supply and transportation of all sizes swaged poles up to site confirming to IS 2713 / 1980 specifications. The pole should be painted with primary coat of red oxide andblackbituminouspaintuptogroundlevelwithbase plate,includingcostofallmaterialsetc.,complete.(Rate per K. G) |
| 3552 | Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 3553 | Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges |
| 3554 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 3555 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 3556 | supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 3557 | supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 3558 | supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 3559 | Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 3560 | Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete. |
| 3561 | Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 3562 | Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 3563 | Supply of 9\" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT |
| 3564 | Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs. |
| 3565 | Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 3566 | Construction of 4.0 Mts diaInfiltration well cum Pump house in the bed of Champavathi River near at Kondapeta (Balance work). |
| 3567 | Providing plugging of well with 40mm HBG metal including cost and conveyence of all materials and labour charge |
| 3568 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete with all de-lift charges but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (PumpHouse Sidewalls) |
| 3569 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Centre Beam) |
| 3570 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Floor Slab 0.2m Thick) |
| 3571 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Lintel Beams Alround) |
| 3572 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Roof Beams) |
| 3573 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Roof slab 0.15m Thick) |
| 3574 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using concrete mixerwith 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402 (For Sunshade of 0.60mts wide and thickness of .075mts at fixed end and 0.05mts.at free end) |
| 3575 | Supply and fixing of50 mm thick pre-cast Cement Jali of approved design including cost and conveyance to work spot and all labour charges for fixing in position etc.complete as per S.S |
| 3576 | Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thickwith 1kg of water proof compound per bag of cementlaid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work BLD-CSTN-8-25 |
| 3577 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. (Inside) |
| 3578 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. (Outside) |
| 3579 | Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 3580 | Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCAlaths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 |
| 3581 | Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work BLD-CSTN-11-30 (For Pump house1.35x1.20m size) |
| 3582 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works, including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work. |
| 3583 | Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface to required smoothness and slopes and thread lining including cost of all materials like cement, metal, sand and water etc., complete, including seigniorage charges, etc., complete for finished item of work, but excluding the cost of conveyance of all materials.BLD-CSTN-7-13 |
| 3584 | Fabrication, supply and transportation of all sizes swaged poles up to site confirming to IS 2713 / 1980 specifications. The pole should be painted with primary coat of red oxide andblackbituminouspaintuptogroundlevelwithbase plate,includingcostofallmaterialsetc.,complete.(Rate per K. G) |
| 3585 | Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 3586 | Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges |
| 3587 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 3588 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 3589 | supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 3590 | supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 3591 | supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 3592 | Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 3593 | Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete. |
| 3594 | Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 3595 | Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 3596 | Supply of 9\" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT |
| 3597 | Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs. |
| 3598 | Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 3599 | Construction ofApproachBridge from the InfiltrationWell Cum Pump House at Jarajaupeta. |
| 3600 | Augoring and boring of holes in site for Bored cast-in-situ R.C.C. Piles for building foundations in loamy, clayey soils like Black cotton soils and ordinary soils without under reams as per IS 2911 - 1980 as per approved designs including all operations, incidental, labour charges, hire charges of machinery, augur bore drill and shell equipment, etc, complete for all depths and for finished item of work for piles upto 300mm dia |
| 3601 | Supply,and Delivery of 6mm thick 300mm dia M.S.Liner Pipe for inserting in the Pile in Sandy Soil to an average Depth of 10 mts. (3.14x0.306=0.961) |
| 3602 | Earth Work Excavation in Sandy Soil with initial lead of 100 mts and lift of 3 mts as per s/s |
| 3603 | Plain Cement concrete (1:4:8) using 40 mm metal with concrete mixture.All work upto plinth level. |
| 3604 | Supply and placing of the Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, pouring concrete by tremmy, curing etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including tremmy pumping, laying concrete, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. (Piles Concrete ) |
| 3605 | Supply and placing of the Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, pouring concrete by tremmy, curing etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including tremmy pumping, laying concrete, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (Pile Caps) |
| 3606 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Longitudinal connecting beams Pile Caps) |
| 3607 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Width wise connecting(Cross Beams)) |
| 3608 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Columns above Pile Caps ) |
| 3609 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Bracing Beams connecting columns at 3mts ) |
| 3610 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (For RoofBeams Longitudinal connecting Columns ) |
| 3611 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(For Roof Beams Width wise connecting Columns ) |
| 3612 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (For Roof slab of 200mm Thick ) |
| 3613 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 3614 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. |
| 3615 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 3616 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. |
| 3617 | Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 3618 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 3619 | Construction ofApproach Bridge from the InfiltrationWell Cum Pump House near Railway Bridge. |
| 3620 | Augoring and boring of holes in site for Bored cast-in-situ R.C.C. Piles for building foundations in loamy, clayey soils like Black cotton soils and ordinary soils without under reams as per IS 2911 - 1980 as per approved designs including all operations, incidental, labour charges, hire charges of machinery, augur bore drill and shell equipment, etc, complete for all depths and for finished item of work for piles upto 300mm dia |
| 3621 | Supply,and Delivery of 6mm thick 300mm dia M.S.Liner Pipe for inserting in the Pile in Sandy Soil to an average Depth of 10 mts. (3.14x0.306=0.961) |
| 3622 | Earth Work Excavation in Sandy Soil with initial lead of 100 mts and lift of 3 mts as per s/s |
| 3623 | Plain Cement concrete (1:4:8) using 40 mm metal with concrete mixture.All work upto plinth level. |
| 3624 | Supply and placing of the Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, pouring concrete by tremmy, curing etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including tremmy pumping, laying concrete, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. (Piles Concrete (No Centering Charges are required)) |
| 3625 | Supply and placing of the Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, pouring concrete by tremmy, curing etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including tremmy pumping, laying concrete, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (Pile Caps) |
| 3626 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Longitudinal connecting Pile Caps) |
| 3627 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Width wise connecting(Cross Beams)) |
| 3628 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Columns above Pile Caps ) |
| 3629 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Bracing Beams connecting columns at 3mts ) |
| 3630 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (For RoofBeams Longitudinal connecting Columns ) |
| 3631 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(For Roof Beams Width wise connecting Columns ) |
| 3632 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (For Roof slab of 200mm Thick ) |
| 3633 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 3634 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. |
| 3635 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 3636 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. |
| 3637 | Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 3638 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 3639 | Construction ofApproachBridge from the InfiltrationWell Cum Pump House at Kondapeta. |
| 3640 | Augoring and boring of holes in site for Bored cast-in-situ R.C.C. Piles for building foundations in loamy, clayey soils like Black cotton soils and ordinary soils without under reams as per IS 2911 - 1980 as per approved designs including all operations, incidental, labour charges, hire charges of machinery, augur bore drill and shell equipment, etc, complete for all depths and for finished item of work for piles upto 300mm dia |
| 3641 | Supply,and Delivery of 6mm thick 300mm dia M.S.Liner Pipe for inserting in the Pile in Sandy Soil to an average Depth of 10 mts. (3.14x0.306=0.961) |
| 3642 | Earth Work Excavation in Sandy Soil with initial lead of 100 mts and lift of 3 mts as per s/s |
| 3643 | Plain Cement concrete (1:4:8) using 40 mm metal with concrete mixture.All work upto plinth level. |
| 3644 | Supply and placing of the Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, pouring concrete by tremmy, curing etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including tremmy pumping, laying concrete, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. (Piles Concrete (No Centering Charges are required)) |
| 3645 | Supply and placing of the Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, pouring concrete by tremmy, curing etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including tremmy pumping, laying concrete, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (Pile Caps) |
| 3646 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Longitudinal connecting Pile Caps) |
| 3647 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Width wise connecting(Cross Beams)) |
| 3648 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(Columns above Pile Caps ) |
| 3649 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (Bracing Beams connecting columns at 3mts ) |
| 3650 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (For RoofBeams Longitudinal connecting Columns ) |
| 3651 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402)(For Roof Beams Width wise connecting Columns ) |
| 3652 | Providing VRCC M30 Grade Design Concrete Mix corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including seignorage charges including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curingwith cement content 400Kgs/Cum as per I.S code from standard suppliers approved by the department including centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) (For Roof slab of 200mm Thick ) |
| 3653 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126)(BLD-CSTN-2-18)unit 1.00 MT GF |
| 3654 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD. |
| 3655 | Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work |
| 3656 | Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. |
| 3657 | Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 3658 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 3659 | Supply, delivery, and erection of clear water SubmersiblePumpsetsfor the designed head and Discharge conditions. [(22.5 KW - 2Nos(1W+1S), 7.5 KW(1W+1S), 15KW(1W+1S), 22.5KW(1W+1S) |
| 3660 | Providing Raw Water Pumping system at Champavati river by supply, delivery and erection ofNon Clog Submersible pump set (Sump pump) with specifications ofHead range of 58 mtrs, discharge of 19 lps for Raw Water(1 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.At Proposed Infiltraiton well cum pumphouse at Jarajapupeta to the proposed 500KL ElSR for Zone-I at High School Road at Jarajapupeta |
| 3661 | Providing Raw Water Pumping system at Champavati river by supply, delivery and erection ofNon Clog Submersible pump set (Sump pump) with specifications ofHead range of 59 mtrs, discharge of 15 lps for Raw Water(1 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.At proposed Infiltraiton well cum pumphouse near Railway Bridgeto the existing 200KL ElSR at Gandhinagar and 120 KL ELST at Saliveedhi. |
| 3662 | Providing Raw Water Pumping system at Champavati river by supply, delivery and erection ofNon Clog Submersible pump set (Sump pump) with specifications ofHead range of 39 mtrs, discharge of 10 lps for Raw Water(1 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. For pumping of Clear water fromproposed Infiltraiton well cum pumphouse at kondapetato the proposed 300KL ElSR at Kondapeta. |
| 3663 | Providing Raw Water Pumping system at Champavati river by supply, delivery and erection ofNon Clog Submersible pump set (Sump pump) with specifications ofHead range of 66 mtrs, discharge of 19 lps for Raw Water(1 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 3664 | Supply and Delivery of Submersible Pump set: Supply, erection, testing and commissioning ofSubmersible pump set with specifications ofHead and discharge as per above requirement, Speed of pump should be capable for carrying the required NPSHR as per the available NPSHA in site condition and the difference in between NPSHA and NPSHR should bemore than 0.50 Mtr as per HIS code, The pump performance curves should be capable to run in a different speeds without falling head and the discharge may varyaccording to approved pump curve by using VFD Control, field efficiency should not less than 70%,pump material constructions of casing and belmouth with cast iron, impeller, shaft sleeves and wearings withbronze, shaft with SS410 pump driven withLT Squirrel cage induction(Minimum 10% greater thanBKW of pump and nearest available capacity available) with specifications of 3 Phase, 415 Volts, 50HZ, (Syn) RPM ,Equilant to IE-3 and above claas,\"F\" Class insulation, suitable to voltage variation +/- 10% & frequency variation +/- 5% confirming to IS 325/IS 4722 with the accessories of common base frame, Guide rail unit and foundation boltsetc., complete including test certificate from the manufacturer should be submitted by the contractor - 1 Unit |
| 3665 | Erection of pump: Errection, testing and commissioning of above Submersible pump set with suitable holding brackets/ Guiderail arrangement, motor and pump unit erected in open wee, lowering, Jointing with sutable equipment, masionery works, given electrical connections and testing. - 1 Unit |
| 3666 | Internal Pipe lines: Deviery Lines : Supply, laying and jointing of suitable size of MS Flanged pipes from pump to common header by connecting with MS Concentric tapper.Common Header:Supply, laying and jointing of suitable size ofMS Flanged pipes from individual pump main to out side of the pump house. Note: The selected size of the MS/DI Pipe diametersfor above lines cannot be affcting the pump performance - 1 Set |
| 3667 | Valves & Accessories for Pipe lines at Pump House:A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump.B.Arranging ofGate/Butterfly valve & Expansion Bellow on common header at out side of the pump house.C.fixing of suitable dia pressure guages with Gliseron filled by providing safety cock on Individual Pump Delivery and common header - 1 Set |
| 3668 | Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proofMCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete - 1 set |
| 3669 | Suitable capacity ofMCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer- 1 Nos |
| 3670 | Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare - 2 Nos |
| 3671 | Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station - 1 Nos |
| 3672 | ProvidingDOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps -2 Sets |
| 3673 | Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB\"s for control wiring including Power transformer etc., complete for total control panel -1 Set |
| 3674 | Supply, laying, termination and testing suitable capacity of3.0 core PVC sheeted, Copper Submersible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying withsuitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work,laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) - 1.00 Lot |
| 3675 | Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.- 1.00Lot |
| 3676 | Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc; - 1.00 Set |
| 3677 | Ring Spanner 3/16 to 1\" - 1 Nos |
| 3678 | Double end spanner set 3/16\" to 1\" - 1 Nos |
| 3679 | Pipe Wrench 18\" & 4\" - 2 Nos |
| 3680 | Screw drivers 6\", 10\" & 12\" - 3 Nos |
| 3681 | Cutting Plier 12\"- 1.00 Nos |
| 3682 | 2 Kgs Hammer with Handle- 1 Nos |
| 3683 | Nose Plier- 1 Nos |
| 3684 | Flat and Half round smooth file - 2 Sets |
| 3685 | Adjustable Spanner 6\" - 1 Set |
| 3686 | Column pipe Clamps- 2.00 Pair |
| 3687 | Line Shaft Clamps - 1.00 Pair |
| 3688 | Line rope and clamps double the weight of pump- 2 Sets |
| 3689 | Gland thghtening Spanner- 1.00 Nos |
| 3690 | Spitter removing Spanner- 1.00 Nos |
| 3691 | Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete |
| 3692 | Fire extiguisher 3Kg capacity- 2.00 Nos |
| 3693 | Rubber Mat 6\" x 4\"- 2 Nos |
| 3694 | Fire Buckets with stand and three buckets - 1.00 No. |
| 3695 | Rubber Hand Gloves- 1.00 Set |
| 3696 | Danger Board Plates - 4 Nos |
| 3697 | First aid kit with chart- 1.00 Nos |
| 3698 | Shock Treatment Chart- 1.00 Nos |
| 3699 | Portable rechargeble torch light - 1.00 Nos |
| 3700 | Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc; - 1.00 Nos |
| 3701 | Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMBof standard make, including the required MS ISMC, MS angular iron,travelling trolley andchain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc., - 1.00 Set |
| 3702 | All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Boardand Cable trench etc Complete as directed by the Field Engineer - 1.00 Set |
| 3703 | Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection - 1 Job |
| 3704 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 3705 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 3706 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 3707 | Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. |
| 3708 | VFD (HD) for the same capacity of selected motor on the above with the specifications ofthe VFD shall be designed to operating temperature at 50 deg C.. ambient without deration, having facility to trip at Over temperature of VFD heat sink shall be above 115 deg C..,LCD keypadshould be built in display unit with graphical trend monitor, have life monitoring functions for devices like IGBT, Cooling fans and capacitors, communication protocol of profinetandadvanced open loop vector control - 1 Set |
| 3709 | Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder - 1.00 Set |
| 3710 | Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder- 1.00 Set |
| 3711 | Power transformer, required push buttons and MFM for each Main pump feeder - 1.00 Set |
| 3712 | Supply,laying, jointing, testing and commissioning of200mm DI K9 Pumpingmain from the proposed Infiltration well cumPumphouse near the existing Infiltration well at Jarajapupeta to the proposed 500KL ElSRat High School Road in Zone - I. |
| 3713 | Cutting of Road surface including stacking of excavated material for pipe line trenches |
| 3714 | Cutting of BT Raoad |
| 3715 | Cutting open CC Road |
| 3716 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Mechanical Means) |
| 3717 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Manual Means) |
| 3718 | Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation andexcluding all taxes etc.complete. (200 DN DI K9) |
| 3719 | Collection ,supply,spreading and compaction of Sandfor filling to the pipes including material, labour curing etc as per SS.At road crossings |
| 3720 | Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy PowderCoating(EP-P) (Min:250 Micron) inside andOutside of Color Blue RAL 5005. All internalparts such as Float, shell, Cove Bolts etc.made of Austenitic alloy steel of SS AISI304/316 and DN 50 float of and othercomponents with ABS/PTFE/EPDM/NBR andgenerally conforming to IN/BIS/AWWAstandards (or) combination Flange drilling asper IS - 1538 and exclusive of all taxes and includingtransportation. (80 DN AIR VALVE) |
| 3721 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538.(200 mm Dia) |
| 3722 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538.(150 mm Dia) |
| 3723 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 200 DN Flanged /Socket tail piece |
| 3724 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax 200 DN Flanged /Spigot tail piece |
| 3725 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)200 DN Double Flanged 45° bend |
| 3726 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 200 DN Double Flanged 22 1/2° bend |
| 3727 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 200 DN Double Flanged 90 bend |
| 3728 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 200 X200 X 80 All Flanged \"T\" |
| 3729 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 200 X200 X 150 All Flanged \"T\" |
| 3730 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 mm dia ducketfoot bend |
| 3731 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 mm dia D/F 1.00 m Pipe |
| 3732 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 200 mm |
| 3733 | Jointing CI /DI pipes & fittings with s/s ends including cost of piglead, Spun yarn and sundries such as cost of fuel for melting lead,filling with water with lead up to 500m and testing to requiredpressure complete. (Reference to specifications. BISNo.3114/94/12288:1997)Dia 200 mm DI |
| 3734 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 200 mm dia |
| 3735 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 150 mm dia |
| 3736 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/Air cushion valve excluding cost of jointing material such as bolts, nuts and rubber insertions etc., complete80 mm ( Air Valve) |
| 3737 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 200 mm dia |
| 3738 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 150 mm dia |
| 3739 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 200 mm dia specials |
| 3740 | Construction ofTrust blocks with RCC M20 mix suitable to the sluice valves including cost and conveyance of all materials and all labour charges etc.complete as per S.Sandfor finished item of work. |
| 3741 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 200 mm dia |
| 3742 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges.150 mm dia |
| 3743 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 100 mm( Air Valve) |
| 3744 | Supply & delivery of HYSD Fe500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 3745 | Collection ,supply,spreading and compaction of crusher stone dustfor filling to the pipe line trenches including material, labour curing etc as per SS. Restoration |
| 3746 | Plain Cement concrete nominal mix M-30 (Cement : fine aggregate: coarse aggregate ) using 20mm size Hard Granite Machine CrushedGraded Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work with nomonal reinforcement for Road restoration. |
| 3747 | Supply,laying, jointing, testing and commissioning of 150 mm DI K9 Pumpingmainsfrom the exisitng Infiltation well No.3 tothe proposed 300 KL ElSR in Zone-IV nearChandra Babu Naidu Colony |
| 3748 | Cutting of Road surface including stacking of excavated material for pipe line trenches |
| 3749 | Cutting of BT Raoad |
| 3750 | Cutting open CC Road |
| 3751 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Mechanical Means) |
| 3752 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Manual Means) |
| 3753 | Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation andexcluding all taxes etc.complete. 150mm DI K9 |
| 3754 | Collection ,supply,spreading and compaction of Sandfor filling to the pipes including material, labour curing etc as per SS.At road crossings |
| 3755 | Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy PowderCoating(EP-P) (Min:250 Micron) inside andOutside of Color Blue RAL 5005. All internalparts such as Float, shell, Cove Bolts etc.made of Austenitic alloy steel of SS AISI304/316 and DN 50 float of and othercomponents with ABS/PTFE/EPDM/NBR andgenerally conforming to IN/BIS/AWWAstandards (or) combination Flange drilling asper IS - 1538 and exclusive of all taxes and includingtransportation. 80 DN AIR VALVE |
| 3756 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. 150mm Dia |
| 3757 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. 150 mm dia scour valve |
| 3758 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Flanged /Socket tail piece |
| 3759 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Flanged /Spigot tail piece |
| 3760 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Double Flanged 45° bend |
| 3761 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Double Flanged 22 1/2° bend |
| 3762 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 DN Double Flanged 90 bend |
| 3763 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 X200 X 80 All Flanged \"T\" |
| 3764 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 X150 X 150 All Flanged \"T\" |
| 3765 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 mm dia ducketfoot bend |
| 3766 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 mm dia D/F 1.00 m Pipe |
| 3767 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 150 mm Dia |
| 3768 | Jointing CI /DI pipes & fittings with s/s ends including cost of piglead, Spun yarn and sundries such as cost of fuel for melting lead,filling with water with lead up to 500m and testing to requiredpressure complete. (Reference to specifications. BISNo.3114/94/12288:1997) 150 mm Dia |
| 3769 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 150 mm Dia |
| 3770 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 150 mm dia |
| 3771 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/Air cushion valve excluding cost of jointing material such as bolts, nuts and rubber insertions etc., complete 80 mm ( Air Valve) |
| 3772 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 150 mm dia |
| 3773 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 150 mm dia |
| 3774 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5)150 mm dia specials |
| 3775 | Construction ofTrust blocks with RCC M20 mix suitable to the sluice valves including cost and conveyance of all materials and all labour charges etc.complete as per S.Sandfor finished item of work. |
| 3776 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 200 mm dia |
| 3777 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 150 mm dia |
| 3778 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 100 mm( Air Valve) |
| 3779 | Supply & delivery of HYSD Fe500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 3780 | Collection ,supply,spreading and compaction of crusher stone dustfor filling to the pipe line trenches including material, labour curing etc as per SS. Restoration |
| 3781 | Plain Cement concrete nominal mix M-30 (Cement : fine aggregate: coarse aggregate ) using 20mm size Hard Granite Machine CrushedGraded Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work with nomonal reinforcement for Road restoration. |
| 3782 | Supply,laying, jointing, testing and commissioning of 150 mm DI K9 Pumpingmainfrom the proposed Infiltraionwell cum Pump house at Kondapeta toproposed 200 KL ElSR nearKondapeta. |
| 3783 | Cutting of Road surface including stacking of excavated material for pipe line trenches |
| 3784 | Cutting of BT Raoad |
| 3785 | Cutting open CC Road |
| 3786 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Mechanical Means) |
| 3787 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Manual Means) |
| 3788 | Collection ,supply,spreading and compaction of sandfor filling to the pipes including material, labour curing etc as per SS.At road crossings |
| 3789 | Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy PowderCoating(EP-P) (Min:250 Micron) inside andOutside of Color Blue RAL 5005. All internalparts such as Float, shell, Cove Bolts etc.made of Austenitic alloy steel of SS AISI304/316 and DN 50 float of and othercomponents with ABS/PTFE/EPDM/NBR andgenerally conforming to IN/BIS/AWWAstandards (or) combination Flange drilling asper IS - 1538 and exclusive of all taxes and includingtransportation 80 DN AIR VALVE |
| 3790 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538.150mm Dia |
| 3791 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. 150 mm dia scour valve |
| 3792 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Flanged /Socket tail piece |
| 3793 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Flanged /Spigot tail piece |
| 3794 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Double Flanged 45° bend |
| 3795 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Double Flanged 22 1/2° bend |
| 3796 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 DN Double Flanged 90 bend |
| 3797 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 X200 X 80 All Flanged \"T\" |
| 3798 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 X150 X 150 All Flanged \"T\" |
| 3799 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 mm dia ducketfoot bend |
| 3800 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 150 mm dia D/F 1.00 m Pipe |
| 3801 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 150 mm Dia |
| 3802 | Jointing CI /DI pipes & fittings with s/s ends including cost of piglead, Spun yarn and sundries such as cost of fuel for melting lead,filling with water with lead up to 500m and testing to requiredpressure complete. (Reference to specifications. BISNo.3114/94/12288:1997) 150 mm Dia |
| 3803 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 150 mm Dia |
| 3804 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 150 mm dia |
| 3805 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/Air cushion valve excluding cost of jointing material such as bolts, nuts and rubber insertions etc., complete 80 mm ( Air Valve) |
| 3806 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 150 mm dia |
| 3807 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 150 mm dia |
| 3808 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 150 mm dia specials |
| 3809 | Construction ofTrust blocks with RCC M20 mix suitable to the sluice valves including cost and conveyance of all materials and all labour charges etc.complete as per S.Sandfor finished item of work. |
| 3810 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges.200 mm dia |
| 3811 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 150 mm dia |
| 3812 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 80 mm( Air Valve) |
| 3813 | Supply & delivery of HYSD Fe500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 3814 | Collection ,supply,spreading and compaction of crusher stone dustfor filling to the pipe line trenches including material, labour curing etc as per SS. Restoration |
| 3815 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 3816 | Supply,laying, jointing, testing and commissioning of 100mm DI K9 Pumpingmain fromJunction \"B\" at Hanuman Temple to existing 120 Kl E.L.S.R at Saslivedhi. |
| 3817 | Cutting of Road surface including stacking of excavated material for pipe line trenches |
| 3818 | Cutting of BT Raoad |
| 3819 | Cutting open CC Road |
| 3820 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Mechanical Means) |
| 3821 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Manual Means) |
| 3822 | Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation andexcluding all taxes etc.complete. 100mm DI K9 |
| 3823 | Collection ,supply,spreading and compaction of sandfor filling to the pipes including material, labour curing etc as per SS.At road crossings |
| 3824 | Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy PowderCoating(EP-P) (Min:250 Micron) inside andOutside of Color Blue RAL 5005. All internalparts such as Float, shell, Cove Bolts etc.made of Austenitic alloy steel of SS AISI304/316 and DN 50 float of and othercomponents with ABS/PTFE/EPDM/NBR andgenerally conforming to IN/BIS/AWWAstandards (or) combination Flange drilling asper IS - 1538 and exclusive of all taxes and includingtransportation. 80 DN AIR VALVE |
| 3825 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. 100mm Dia |
| 3826 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. 100 mm dia scour valve |
| 3827 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 DN Flanged /Socket tail piece |
| 3828 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 DN Flanged /Spigot tail piece |
| 3829 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 DN Double Flanged 45° bend |
| 3830 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 DN Double Flanged 22 1/2° bend |
| 3831 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 DN Double Flanged 90 bend |
| 3832 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 X200 X 80 All Flanged \"T\" |
| 3833 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 X150 X 150 All Flanged \"T\" |
| 3834 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 mm dia ducketfoot bend |
| 3835 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 100 mm dia D/F 1.00 m Pipe |
| 3836 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 100 mm Dia |
| 3837 | Jointing CI /DI pipes & fittings with s/s ends including cost of piglead, Spun yarn and sundries such as cost of fuel for melting lead,filling with water with lead up to 500m and testing to requiredpressure complete. (Reference to specifications. BISNo.3114/94/12288:1997) 100 mm dia |
| 3838 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 100 mm Dia |
| 3839 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 100 mm Dia |
| 3840 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/Air cushion valve excluding cost of jointing material such as bolts, nuts and rubber insertions etc., complete80 mm ( Air Valve) |
| 3841 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 100 mm dia |
| 3842 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 100 mm dia |
| 3843 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 100 mm dia specials |
| 3844 | Construction ofTrust blocks with RCC M20 mix suitable to the sluice valves including cost and conveyance of all materials and all labour charges etc.complete as per S.Sandfor finished item of work. |
| 3845 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 200 mm dia |
| 3846 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 150 mm dia |
| 3847 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 100 mm( Air Valve) |
| 3848 | Supply & delivery of HYSD Fe500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 3849 | Collection ,supply,spreading and compaction of crusher stone dustfor filling to the pipe line trenches including material, labour curing etc as per SS. Restoration |
| 3850 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 3851 | Replacement of existing AC Pumping mains from Well No.5 and Well no.6 catering to GLSR at Naidu colony and GLSR at NagarPanchayat Office with 150mm DI K9 and 200mm DI K9 pipelines. |
| 3852 | Cutting of Road surface including stacking of excavated material for pipe line trenches |
| 3853 | Cutting of BT Raoad |
| 3854 | Cutting open CC Road |
| 3855 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Mechanical Means) |
| 3856 | Earthwork excavation and depositing on bank in all type of soils like black cotton soils, red earth and ordinary gravel, hard gravally soils, soft disintegrated rock like shales, ordinary gravel, stoney earth and earth mixed with fair sized boulders etc. complete as per S.S (Ordinary Soil By Manual Means) |
| 3857 | Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation andexcluding all taxes etc.complete. 200 DN. D.I. K9 Pipe Line |
| 3858 | Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation andexcluding all taxes etc.complete. 150 DI K9 |
| 3859 | Collection ,supply,spreading and compaction of sandfor filling to the pipes including material, labour curing etc as per SS.At road crossings |
| 3860 | Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy PowderCoating(EP-P) (Min:250 Micron) inside andOutside of Color Blue RAL 5005. All internalparts such as Float, shell, Cove Bolts etc.made of Austenitic alloy steel of SS AISI304/316 and DN 50 float of and othercomponents with ABS/PTFE/EPDM/NBR andgenerally conforming to IN/BIS/AWWAstandards (or) combination Flange drilling asper IS - 1538 and exclusive of all taxes and includingtransportation. 80 DN AIR VALVE |
| 3861 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. 200mm Dia |
| 3862 | Manufacture, Supply and delivery ofDI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions,wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89tYPE-A/IS14846/DIN -3202 F4/BS/:5163 .All the valves should be with Electrostatic powder coating both inside and outsidepocket less body passage. Drilled as per IS:1538. 150 mm dia scour valve |
| 3863 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 200 DN Flanged /Socket tail piece |
| 3864 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax) 200 DN Flanged /Spigot tail piece |
| 3865 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)200 DN Double Flanged 45° bend |
| 3866 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)200 DN Double Flanged 22 1/2° bend |
| 3867 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)200 DN Double Flanged 90 bend |
| 3868 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)200 X200 X 80 All Flanged \"T\" |
| 3869 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)200 X200 X 150 All Flanged \"T\" |
| 3870 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 mm dia ducketfoot bend |
| 3871 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 mm dia D/F 1.00 m Pipe |
| 3872 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 DN Flanged /Socket tail piece |
| 3873 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 DN Flanged /Spigot tail piece |
| 3874 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 DN Double Flanged 45° bend |
| 3875 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 DN Double Flanged 22 1/2° bend |
| 3876 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 DN Double Flanged 90 bend |
| 3877 | Supply & Delivery of Centrifugally cast (spun) Ductile Iron fittings PN 1.6 conforming to IS:9523/2000, zinc coated externally with inside mortor lining suitable for DIpipes (with finishing Class 13/IS 9523/2000) including transportation, including all taxes & duties etc complete but excluding V.A.T.(Turn Over Tax)150 X150 X 200 All Flanged \"T\" |
| 3878 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 200 mm Dia |
| 3879 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 150 DI K9 From Well6 to connecting to 200mm DI K9 |
| 3880 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 150 DI K9 from well 5 to connection to 200mm DI k9 |
| 3881 | Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/sends carefully into trenches and laying them true to alignment andgradient including all sundries but excluding cost and conveyance ofpipes from source of supply (Ref to specifications. BISNo.3114/1994) 150 DI K9 to GLSR at Naidu colony |
| 3882 | Jointing CI /DI pipes & fittings with s/s ends including cost of piglead, Spun yarn and sundries such as cost of fuel for melting lead,filling with water with lead up to 500m and testing to requiredpressure complete. (Reference to specifications. BISNo.3114/94/12288:1997) 200 mm dia |
| 3883 | Jointing CI /DI pipes & fittings with s/s ends including cost of piglead, Spun yarn and sundries such as cost of fuel for melting lead,filling with water with lead up to 500m and testing to requiredpressure complete. (Reference to specifications. BISNo.3114/94/12288:1997) 150 mm dia |
| 3884 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 200 mm Dia |
| 3885 | Lowering, keeping in position and fixing C.I. D.I sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces PHE-CISP-15 150 mm Dia |
| 3886 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/Air cushion valve excluding cost of jointing material such as bolts, nuts and rubber insertions etc., complete80 mm ( Air Valve) |
| 3887 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 200 mm dia |
| 3888 | Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (PHE-JCIF-5) 150 mm dia |
| 3889 | Construction ofTrust blocks with RCC M20 mix suitable to the sluice valves including cost and conveyance of all materials and all labour charges etc.complete as per S.Sandfor finished item of work. |
| 3890 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 200 mm dia |
| 3891 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 150 mm dia |
| 3892 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 100 mm( Air Valve) |
| 3893 | Supply & delivery of HYSD Fe500 grade reinforcement steel including cost and conveyance to site & labour charges, cutting, bending, fabrication, binding of reinforcement, including cost of binding wire etc., complete as per SS but excluding all taxes & duties |
| 3894 | Collection ,supply,spreading and compaction of crusher stone dustfor filling to the pipe line trenches including material, labour curing etc as per SS. Restoration |
| 3895 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 3896 | Construction of 500 KL capacity ELSR with 15.00 mts stagging at Jarajapupeta High School Groundfor Zone - I (Balance work) |
| 3897 | Construction of 500 KL capacity ELSR with a staging of 15 m with VRCC M30 mix including fixtures mentioned below.All the Items Covered in mentioned in the S.No.43 of Public Health Items of AP SOR 2024-251) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs 60000/- per MT(Fe 500) (BoCE rates for the month of March-2024).2) All concrete components shall be designed with M30 Design Mix proportion.3) For intermediate capacities proportional rates shall be adopted.4) The foundations shall be designed for Annular Raft Footings. The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqma) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on basic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate up to 20 T/Sqmc) For SBC 10T/Sqm to 7.5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate.5)For staging less than 15 m, the rate shall be decreased by Rs.0.05 paisa on basic rate per liter per every Meter decrease in staging6) For staging above 15 m, the rate shall be increased by Rs.0.10 paisa on basic rate per liter per every Meter additional staging.7) The above rates shall be increased / decreased due to increase/decrease in the cost of cement by Basic rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.8) The above rates shall be increased / decreased due to increase/decrease in the cost of Steel by Basic rate x {(Rs-60000)/60000} x0.2 Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate. { (Rs-41300)/41300} x0.2 Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof.b)The rate inclusive of 2 coats of weather proof emulsion painting for external surfaces, lettering, all required fixtures, Pipes, Pipe specials, valves of DI material, Valve chambers etc., for pipe connections including cost of pipes, specials and valves as per departmental designs and drawings.10)For tribal/Agency / Rural area, the above rates as arrived up to shall be increased by 10%.11) The above rates adopted for a wind pressure up to \"250 kg/Sqm\". For every 100 kg/Sqm decrease in wind pressure, the rate shall be decreased by 5%12)a) The Basic rate is adopted by considering the design for Seismic forces for Zone- II only of seismic zones.(b) The basic rates shall be increased by 15 % for Zone-III of seismic zones.13-(a). The ELSR/OHSR shall be designed with minimum of two rows of columns for capacities above 500 KL & up to 1000KL.13-(b). The ELSR/OHSR shall be designed with minimum of three rows of columns for capacities above 1000KL.14. The shaft type staging with slip form can also be provided with proper approval from competent authority without any additional cost15) The basic rate is inclusive of following Fixturesi)Pipe connections & Specials with D.I materialsAll pipe connections for Inlet, Out let, Over Flow, Scour pipes shall be provided with D/F DI material. (b) The Valves for above pipe connections also shall be of DI material of PN 16 duty confirming to the specification of SoR item No.28(c) All specials such as Bends, Tees, Reducers, Duck foot Bends, Bell mouths etc,. Shall be of DI material.The sizes of the verticals for ELSR/OHSR shall be:For 500 KL to 750 Kl ELSRs Inlet Pipe - 300mm dia. Out let Pipe - 350mm dia.DI valves – 2 No’s Over Flow pipe - 350m dia. Scour Pipe - 200mm dia.For 800 KL to 1500 Kl ELSRs Inlet Pipe - 400mm dia. Out let Pipe - 450mm dia.DI valves – 2 No’s Over Flow pipe - 450m dia. Scour Pipe - 200mm dia.c) For above 1500 KL to 2500 Kl ELSRsInlet Pipe - 400mm dia. Out let Pipe - 500mm dia.DI valves – 2 No’s Over Flow pipe - 500m dia. Scour Pipe - 200mm dia.Note: Any deviation from the above sizes as per design, shall be paid or recovered.Manhole Frames & Coversa) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min. of 150mm dia.) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos.v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 Noviii) The staircase shall be enclosed with brick masonry walls on three sides and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement. The Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia. pipe & middle railing of 25mm dia. and verticals with 40mm dia. at an interval not more than of 1.00m c/c.xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No)xii) Lightening Arrestor with all its accessories complete including earthing, with relevant IS Codes - 1 No.xiii) Compound wall: Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall is minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM (1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8) prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Ground level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall beII) The sizes of the verticals for ELSR/OHSR shall be:a) For 500 KL to 750 Kl ELSRs Inlet Pipe - 300mm dia. Out let Pipe - 350mm dia.DI valves – 2 No’s Over Flow pipe - 350m dia. Scour Pipe - 200mm dia.b) For 800 KL to 1500 Kl ELSRs Inlet Pipe - 400mm dia. Out let Pipe - 450mm dia.DI valves – 2 No’s Over Flow pipe - 450m dia. Scour Pipe - 200mm dia.c) For above 1500 KL to 2500 Kl ELSRs Inlet Pipe - 400mm dia. Out let Pipe - 500mm dia.DI valves – 2 No’s Over Flow pipe - 500m dia. Scour Pipe - 200mm dia.13(iii) Manhole Frames & Coversa) All man hole Frames & Covers shall be made of CI/DI materials with min. size of 0.60mX 0.60m - For Roof & Valve Chambers.iv) CI/D.I Double Swan neck ventilators (min. of 150mm dia.) shall be provided in top dome and slab with mosquito/fly proof nets - 4Nos.v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.vi) RCC precast ladders of 0.60 m width - 2 Nos.vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C hand railing of 1.0 m height – 1 Noviii) The staircase shall be enclosed with brick masonry walls on three sides and collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement. The Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of 40mm dia. pipe & middle railing of 25mm dia. and verticals with 40mm dia. at an interval not more than of 1.00m c/c.xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional type (1 No)xii) Lightening Arrestor with all its accessories complete including earthing, with relevant IS Codes - 1 No.xiii) Compound wall: Construction of compound wall including ornamental M.S.Gate of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall hall is minimum of 150m. Min. height of the compound wall shall be 1.80m above plinth and thickness 230mm in brick masonry in CM (1:6).The compound wall shall be constructed including earth work excavation in all types of soils for plinth beam of 230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a C.C (1:4:8) prop bed of 100mm thick. The columns shall be of 230X230 mm in size with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be constructed in VRCC M20 grade at Ground level, over a bed of CC(1:4:8)-100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate pillars. All the materials shall be followed as per the standards.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angular of 25mm X 25mm X 4mm in \"Y\" shape to height of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauges shall be stretched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4) prop on both sides of brick work.Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreasedNote:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL shall be as follows.: i)500 KL : 0.086% ii)1000 KL : 0.047% iii)1500 KL : 0.034% iv)2000 KL : 0.026% v)2500 KL : 0.022 % For intermediate capacities, interpolated percentages shall be adopted.xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 Sqm with the following specification: RCC framed structure with concrete grade not less than M20 design mix at the locations specified by the department at the time of execution with veranda, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases.MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides open able shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall be provided. Septic tank for 5 users shall be provided.Tie beam shall be provided above the brick work with 230X200mm size, fixed with MS angular of 25mm X 25mm X 4mm in \"Y\" shape to height of 0.60m, with embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18 gauges shall be stretched in 4 rows (2x2). Plastering shall be done with 16mm thick in two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4) prop on both sides of brick work.Snowcem paint in two coats shall be provided for both sides of wall. The M.S ornamental gate as per the approved drawings shall be provided with minimum of 3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged on four corners of compound wall. If the length of the wall is increased/decreased14Note:-For every 1m increase/decrease in length of compound wall the increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL shall be as follows.: i)500 KL : 0.086% ii)1000 KL : 0.047% iii)1500 KL : 0.034% iv)2000 KL : 0.026% v)2500 KL : 0.022 % For intermediate capacities, interpolated percentages shall be adopted.xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 Sqm with the following specification: RCC framed structure with concrete grade not less than M20 design mix at the locations specified by the department at the time of execution with veranda, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts excluding balconies and staircases.MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond board doors shall be provided. N.C.L. Windows centre fixed both sides open able shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of 12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided. Walls shall be provided with snowcem paint in two coats over primary coat. Electrical and water supply arrangement shall be provided as directed by dept officer. Water Storage tank made with plastic/polymer material of reputed make with necessary out let and inlet connection pipes shall provided. Septic tank for 5 users shall be provided. |
| 3898 | Construction of 200 KL capacity ELSR with 15.00 stagging at Kondapeta for Zone - IIA. (Balance work) |
| 3899 | Construction of 200 KL capacity ELSR with a staging of 10 m with VRCC M30 mix including fixtures mentioned below. The rate include all the Items covered in the S.No.44 of Public Health Items of AP SOR 2024-25NOTE: -1). All concrete members shall be designed with M30 grade design mix.2) For intermediate ranges proportional rates may be adopted 3) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs.59,000/- per MT(Fe 500) (BoCE rates for the month of May-2025).4)The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqm.a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on basic rate.b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate up to 20 T/Sqmc) For SBC 10T/Sqm to 7.5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate. d) For SBC 7.5 T/Sqm to 5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 15% on basic rate) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which additional payment shall be made as per field condition5) For every Meter of staging less than 10 m, the rate shall be reduced by Rs.0.05 paisa per liter per every Meter of difference in staging 6) For every Meter of staging above 10 m , the rate shall be increase by Rs.0.10 paisa per liter per every Meter of additional in staging 7) The above rates shall be increased / decreased due to increase / decrease in the cost of cement by Basic Rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of cement (Rs per Mt) at the time of preparation of estimate8)The above rates shall be increased / decreased due to increase / decrease in the cost of steel by Basic Rate x {(Rs-59000)/59000 x0.2}Rs = Rate of steel (Rs per Mt) at the time of preparation of estimate.9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof.10) The above rates shall be adopted for estimate purposes for construction of ELSR for a finished work including 2 coats of whether proof emulsion painting for external surfaces, lettering, all required fixtures, pipes, bends, valves etc., for pipe connections but excluding cost of pipes, bends and valves as per departmental designs and drawings.11) The above rates are applicable for wind pressures up to 250 kg / Sq m. For decrease in wind pressure the rate has to be decreased by 5% per every 100kg/Sqm. If the ELSR / OHSR are to be designed for seismic forces also, cost shall be arrived by working out detailed quantities based on the designs.12) (a)For tribal/Agency / Rural area, the above rates as arrived up to shall be increased by 10%. (b) An additional increase of 7.50% shall be allowed for OHSRs/ELSRs located in agency areas over the above rates for RWS Department works.13) If the ELSR is to be designed for seismic forces also, cost shall be arrived by working out detailed quantities based on the design & difference to be paid extra 14) If the ELSR is to be designed for seismic forces a) The above rates are applied up to Zone-II earth quake. b) For Zone-III earth quake the above rates are to be increased by 15 %.15) Fixtures include : a) RCC or Aluminum ladder inside 0.60 m wide. b) Spiral staircase on the outside shall be provided up to 200KL. Above 200KL capacity dog legged staircase shall be provided with staircase flight width of 1.0mts and landing width of 1.20mts with S.S railing up to 1.0 height. c) Lightening arrestor, including conductor and earthling etc. d) RCC ventilators with copper or stainless steel fly proof mesh. e) D.I Manholes frame and cover 0.60x0.60 m as per IS specifications (light duty) - 2 Nos. f) Water level indicator of good quality with ebonite/ copper float approved pattern - 1 No. g) The ladder shall be with M.S ladder and Verticals with HDPE of 10kg/Sqcm shall be provided for single column OHSRs only. h) Minimum staging for all ELSR/OHSR shall be 10.0mts. i) The increase in staging shall be at 1.0mt interval. j) The railing provided to the gallery and stair case shall be with stainless steel of grade 304 for a height of 1.20mts. k). The dog legged staircase shall be enclosed with brick/CRS wall on three sides and front side with M.S collapsible gate up to 1st brace level from ground level to prevent unauthorized entry. l). D.I swan neck ventilators shall be provided in top dome and slab. m). The above rates are exclusive of all inlet, out let connection and valves. All valves near inlet, out let and for scour of ELSRs shall be D.I valves of heavy duty confirming to the specification of SoR item No.28 |
| 3900 | Inlet Arrangements |
| 3901 | 200x1.00m long DI DF pipes |
| 3902 | 200x2.00m long DI DF pipes |
| 3903 | Outlet Arrangements |
| 3904 | 250x1.00m long DI DF pipes |
| 3905 | 250x2.00m long DI DF pipes |
| 3906 | Over flow 150mm |
| 3907 | 250x1.00m long DI DF pipes |
| 3908 | 250x2.00m long DI DF pipes |
| 3909 | Scour 100mm |
| 3910 | 150x1.00m long DI DF pipes |
| 3911 | 150x2.00m long DI DF pipes |
| 3912 | Supply, deliveryof D.I. fittings confirming to I.S.No.9523/2000 having dimensions as per table with Zinc coated externally and inside Cement Mortar lining (With finishing as per Class 13/IS 9523/2000) including cost of fittings, transportation, stacking carefully at site. The rate excluding VAT and other duties etc.,complete as per S.S. and as directed by the departmental authorities. 200 Duck foot bends for incoming and outgoing & over flow |
| 3913 | Supply, deliveryof D.I. fittings confirming to I.S.No.9523/2000 having dimensions as per table with Zinc coated externally and inside Cement Mortar lining (With finishing as per Class 13/IS 9523/2000) including cost of fittings, transportation, stacking carefully at site. The rate excluding VAT and other duties etc.,complete as per S.S. and as directed by the departmental authorities for scour 150 duck foot bend |
| 3914 | Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 200mm dia |
| 3915 | Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250mm dia |
| 3916 | Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150mm dia |
| 3917 | Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. PN16 Incoming 200mm dia |
| 3918 | Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. PN16 Outgoing 250mm dia |
| 3919 | Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. PN16 Scour 150mm dia |
| 3920 | Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) of following dia. conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603);Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steel; including transportation and excluding all taxescomplete.PN 1.6 (MPa) - Incoming 200mm dia |
| 3921 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Incoming 200mm dia Sluice valve |
| 3922 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Outgoing250mm dia Sluice valve |
| 3923 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Incoming 200mm dia Check valve |
| 3924 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Scour 150mm dia |
| 3925 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 200mm dia |
| 3926 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 150mm dia |
| 3927 | Construction ofThrust blocks with RCC M20 mix suitable to the sluice valves including cost and conveyance of all materials and all labour charges etc.complete as per S.Sandfor finished item of work. Thrust blocks |
| 3928 | Construction of 300 KL capacity ELSR with 15.00 mts stagging atChandra Babu Naidu Colony for Zone - IV. (Balance work) |
| 3929 | Construction of 300 KL capacity ELSR with a staging of 15 m with VRCC M30 mix including fixtures mentioned below. The Rate includes all the Items covered in the Public Health items S.No.44 of AP SOR 2024-25NOTE: -1). All concrete members shall be designed with M30 grade design mix.2) For intermediate ranges proportional rates may be adopted 3) The above rates are arrived with base rate of Cement Rs.4220/- per MT (as per G.o.Rt.No.2029 Water Resources (Reforms) Dept. Dt:06-10-2022) & Steel Rs 60000/- per MT(Fe 500) (BoCE rates for the month of March-2024). 4) The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for SBC of 15 T/Sqm. a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on basic rate. b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by 1.0% on basic rate up to 20 T/Sqm c) For SBC 10T/Sqm to 7.5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 10% on basic rate. d) For SBC 7.5 T/Sqm to 5 T/Sqm, solid raft shall be provided and for solid raft the rate shall be increased by 15% on basic rate e) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which additional payment shall be made as per field condition. 5) For every Meter of staging less than 10 m, the rate shall be reduced by Rs.0.05 paisa per liter per every Meter of difference in staging 6) For every Meter of staging above 10 m , the rate shall be increase by Rs.0.10 paisa per liter per every Meter of additional in staging 7) The above rates shall be increased / decreased due to increase / decrease in the cost of cement by Basic Rate x {(Rc-4220)/4220} x 0.07 Rc = Rate of cement (Rs per Mt) at the time of preparation of estimate. 8)The above rates shall be increased / decreased due to increase / decrease in the cost of steel by Basic Rate x { (Rs-60000)/60000 x0.2} Rs = Rate of steel (Rs per Mt) at the time of preparation of estimate 9) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner surface of the Reservoir including roof. 10) The above rates shall be adopted for estimate purposes for construction of ELSR for a finished work including 2 coats of whether proof emulsion painting for external surfaces, lettering, all required fixtures, pipes, bends, valves etc., for pipe connections but excluding cost of pipes, bends and valves as per departmental designs and drawings. 11) The above rates are applicable for wind pressures up to 250 kg / Sq m .For decrease in wind pressure the rate has to be decreased by 5% per every 100kg/Sqm. If the ELSR / OHSR are to be designed for seismic forces also, cost shall be arrived by working out detailed quantities based on the designs. 12) (a)For tribal/Agency / Rural area, the above rates as arrived up to shall be increased by 10%. (b) An additional increase of 7.50% shall be allowed for OHSRs/ELSRs located in agency areas over the above rates for RWS Department works. 13) If the ELSR is to be designed for seismic forces also, cost shall be arrived by working out detailed quantities based on the design & difference to be paid extra. 14) If the ELSR is to be designed for seismic forces a) The above rates are applied up to Zone-II earth quake. b) For Zone-III earth quake the above rates are to be increased by 15 %. 15) Fixtures include : a) RCC or Aluminum ladder inside 0.60 m wide. b) Spiral staircase on the outside shall be provided up to 200KL. Above 200KL capacity dog legged staircase shall be provided with staircase flight width of 1.0mts and landing width of 1.20mts with S.S railing up to 1.0 height. c) Lightening arrestor, including conductor and earthling etc. d) RCC ventilators with copper or stainless steel fly proof mesh. e) D.I Manholes frame and cover 0.60x0.60 m as per IS specifications (light duty) - 2 Nos. f) Water level indicator of good quality with ebonite/ copper float approved pattern - 1 No. g) The ladder shall be with M.S ladder and Verticals with HDPE of 10kg/Sqcm shall be provided for single column OHSRs only. h) Minimum staging for all ELSR/OHSR shall be 10.0mts. i) The increase in staging shall be at 1.0mt interval. j) The railing provided to the gallery and stair case shall be with stainless steel of grade 304 for a height of 1.20mts. k). The dog legged staircase shall be enclosed with brick/CRS wall on three sides and front side with M.S collapsible gate up to 1st brace level from ground level to prevent unauthorized entry. l). D.I swan neck ventilators shall be provided in top dome and slab. m). The above rates are exclusive of all inlet, out let connection and valves. All valves near inlet, out let and for scour of ELSRs shall be D.I valves of heavy duty confirming to the specification of SoR item No.28 |
| 3930 | Inlet Arrangements |
| 3931 | 200x1.00m long DI DF pipes |
| 3932 | 200x2.00m long DI DF pipes |
| 3933 | Outlet Arrangements |
| 3934 | 250x1.00m long DI DF pipes |
| 3935 | 250x2.00m long DI DF pipes |
| 3936 | Over flow 150mm |
| 3937 | 250x1.00m long DI DF pipes |
| 3938 | 250x2.00m long DI DF pipes |
| 3939 | Scour 100mm |
| 3940 | 150x1.00m long DI DF pipes |
| 3941 | 150x2.00m long DI DF pipes |
| 3942 | Supply, deliveryof D.I. fittings confirming to I.S.No.9523/2000 having dimensions as per table with Zinc coated externally and inside Cement Mortar lining (With finishing as per Class 13/IS 9523/2000) including cost of fittings, transportation, stacking carefully at site. The rate excluding VAT and other duties etc.,complete as per S.S. and as directed by the departmental authorities. 200 Duck foot bends for incoming and outgoing & over flow |
| 3943 | Supply, deliveryof D.I. fittings confirming to I.S.No.9523/2000 having dimensions as per table with Zinc coated externally and inside Cement Mortar lining (With finishing as per Class 13/IS 9523/2000) including cost of fittings, transportation, stacking carefully at site. The rate excluding VAT and other duties etc.,complete as per S.S. and as directed by the departmental authorities for scour 150 duck foot bend |
| 3944 | Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 200mm dia |
| 3945 | Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250mm dia |
| 3946 | Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150mm dia |
| 3947 | Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. PN16 Incoming 200mm dia |
| 3948 | Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. PN16 Outgoing 250mm dia |
| 3949 | Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/ SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. PN16 Scour 150mm dia |
| 3950 | Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) of following dia. conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603);Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steel; including transportation and excluding all taxescomplete.PN 1.6 (MPa) - Incoming 200mm dia |
| 3951 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Incoming 200mm dia Sluice valve |
| 3952 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Outgoing250mm dia Sluice valve |
| 3953 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Incoming 200mm dia Check valve |
| 3954 | Labour charges for lowering and keeping in position of C.I./DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves. Scour 150mm dia |
| 3955 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 200mm dia |
| 3956 | Construction ofR.C.C.valve chamber in M20 Grade concreteas per Type design including cost & conveyance of all materials , labour charges, formwork,machine mixing,vibration , curing etc.complete but excluding cost of Manhole cover ,reinforcement & its fabrication charges. 150mm dia |
| 3957 | Construction ofThrust blocks with RCC M20 mix suitable to the sluice valves including cost and conveyance of all materials and all labour charges etc.complete as per S.Sandfor finished item of work. Thrust blocks |
| 3958 | PROVIDING 100KVA TRANSFORMER WITH ALL ACCESSORIESIW cum CW cum PH at Champavathi River for Jalajaripeta zone-1 |
| 3959 | Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 3960 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 3961 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 3962 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 3963 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 3964 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 3965 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 3966 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 3967 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 3968 | A) Earth Electrodes |
| 3969 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 3970 | C) Epoxy insulators |
| 3971 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 3972 | Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.Makes : As per list of recommended brands as category I. MAT-04042 a100KVA |
| 3973 | 1. Quantity : 1 |
| 3974 | 2. Rated KVA :100 KVA |
| 3975 | 3. Service & Location: Continuous Outdoor Distribution Transformer |
| 3976 | 4. Mounting : Plinth. |
| 3977 | 5. Wound : CopperDouble wound |
| 3978 | 6. Type :Core type oil immersed |
| 3979 | 7. Cooling : ONAN |
| 3980 | 8. TempRise : 40⁰C in oil 45⁰C by resistance |
| 3981 | 9. Vector Group:Dyn 11 |
| 3982 | 10. Primary Connection :Delta |
| 3983 | 11. Nominal Voltage / Current : ______ |
| 3984 | 12. Highest system Voltage: 12000V |
| 3985 | 13. Primary Frequency :50 HZ +/- 3% |
| 3986 | 14. Number of Phases : 3 |
| 3987 | 15. Primary wires:3 |
| 3988 | 16. Secondary connection : Star |
| 3989 | 17. SecondaryVolts / Current :433V |
| 3990 | 18. Secondary phases :3 |
| 3991 | 19. Secondary wires:4 |
| 3992 | 20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps) |
| 3993 | 21. Terminal arrangement. |
| 3994 | a.HV: HT terminal box as per the site condition. |
| 3995 | b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable |
| 3996 | 22. LV:One separate terminal for earthing. |
| 3997 | 23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats |
| 3998 | 24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats |
| 3999 | 25. Percentage Impedance at 75 deg C AT 4.5 |
| 4000 | 26. No load Current Less than 2% of full load Current |
| 4001 | 27. Standrad Fittings & Accessories. |
| 4002 | a. Rating and terminal marking plate: One |
| 4003 | b. Lifting Lugs:Two |
| 4004 | c. Off-circuit tap switch :One |
| 4005 | d. EarthingTerminals :Two |
| 4006 | e. Radiators ( Attachable):Adequate |
| 4007 | f.Explosion vent with Diaphragm :One |
| 4008 | g. Conservator with Drain plug:one |
| 4009 | h. Oil filling hole with cap :One |
| 4010 | i.Oil level indicator : One |
| 4011 | j.Dehydrating Silicagel Breather : One |
| 4012 | k. Terminal Arrangement: HV With Treminal Box |
| 4013 | l. Terminal Arrangement : LV Cable Box |
| 4014 | m. Separate Neutral Bushing: One |
| 4015 | n. Filter valve with blanking plate : One |
| 4016 | o. Drain cum filter valve with blanking plate : One |
| 4017 | p. Air release device : One |
| 4018 | q. Thermometer Pocket : One |
| 4019 | r. Four :Unidirectional flat rollers |
| 4020 | s. One :10Cm dial thermometer(Rigid stem type) |
| 4021 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 4022 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 4023 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 4024 | Incoming |
| 4025 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4026 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 4027 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 4028 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 4029 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 4030 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 4031 | g).3RYB Phase indication lamps with leds |
| 4032 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 4033 | Out-Going |
| 4034 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4035 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4036 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4037 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4038 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4039 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 4040 | .KWH digital meter fro lighting section |
| 4041 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 4042 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 4043 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 4044 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 4045 | Supply and Laying of 3C X 35Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03456 |
| 4046 | Transformer Yard |
| 4047 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means (column footings) |
| 4048 | Sand filling as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge (column footings ) |
| 4049 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete (column footings ) |
| 4050 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(column footings ) |
| 4051 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(columns) |
| 4052 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(Plinth Beam ) |
| 4053 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours)BLD-CSTN-10-3 |
| 4054 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel barsFe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 4055 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 4056 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 4057 | Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 4058 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 4059 | PROVIDING 100KVA TRANSFORMER WITH ALL ACCESSORIESIW cum CW cum PH-2 at Champavathi River for Existing 200 KL ELSR at Gandhi Nagar Zone -III and 120 KL GLSR at Saali veedhi zone -5 |
| 4060 | Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 4061 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 4062 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 4063 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 4064 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 4065 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 4066 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 4067 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 4068 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 4069 | A) Earth Electrodes |
| 4070 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 4071 | C) Epoxy insulators |
| 4072 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 4073 | Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.Makes : As per list of recommended brands as category I. MAT-04042 a100KVA |
| 4074 | 1. Quantity : 1 |
| 4075 | 2. Rated KVA :100 KVA |
| 4076 | 3. Service & Location: Continuous Outdoor Distribution Transformer |
| 4077 | 4. Mounting : Plinth. |
| 4078 | 5. Wound : CopperDouble wound |
| 4079 | 6. Type :Core type oil immersed |
| 4080 | 7. Cooling : ONAN |
| 4081 | 8. TempRise : 40⁰C in oil 45⁰C by resistance |
| 4082 | 9. Vector Group:Dyn 11 |
| 4083 | 10. Primary Connection :Delta |
| 4084 | 11. Nominal Voltage / Current : ______ |
| 4085 | 12. Highest system Voltage: 12000V |
| 4086 | 13. Primary Frequency :50 HZ +/- 3% |
| 4087 | 14. Number of Phases : 3 |
| 4088 | 15. Primary wires:3 |
| 4089 | 16. Secondary connection : Star |
| 4090 | 17. SecondaryVolts / Current :433V |
| 4091 | 18. Secondary phases :3 |
| 4092 | 19. Secondary wires:4 |
| 4093 | 20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps) |
| 4094 | 21. Terminal arrangement. |
| 4095 | a.HV: HT terminal box as per the site condition. |
| 4096 | b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable |
| 4097 | 22. LV:One separate terminal for earthing. |
| 4098 | 23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats |
| 4099 | 24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats |
| 4100 | 25. Percentage Impedance at 75 deg C AT 4.5 |
| 4101 | 26. No load Current Less than 2% of full load Current |
| 4102 | 27. Standrad Fittings & Accessories. |
| 4103 | a. Rating and terminal marking plate: One |
| 4104 | b. Lifting Lugs:Two |
| 4105 | c. Off-circuit tap switch :One |
| 4106 | d. EarthingTerminals :Two |
| 4107 | e. Radiators ( Attachable):Adequate |
| 4108 | f.Explosion vent with Diaphragm :One |
| 4109 | g. Conservator with Drain plug:one |
| 4110 | h. Oil filling hole with cap :One |
| 4111 | i.Oil level indicator : One |
| 4112 | j.Dehydrating Silicagel Breather : One |
| 4113 | k. Terminal Arrangement: HV With Treminal Box |
| 4114 | l. Terminal Arrangement : LV Cable Box |
| 4115 | m. Separate Neutral Bushing: One |
| 4116 | n. Filter valve with blanking plate : One |
| 4117 | o. Drain cum filter valve with blanking plate : One |
| 4118 | p. Air release device : One |
| 4119 | q. Thermometer Pocket : One |
| 4120 | r. Four :Unidirectional flat rollers |
| 4121 | s. One :10Cm dial thermometer(Rigid stem type) |
| 4122 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 4123 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 4124 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 4125 | Incoming |
| 4126 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4127 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 4128 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 4129 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 4130 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 4131 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 4132 | g).3RYB Phase indication lamps with leds |
| 4133 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 4134 | Out-Going |
| 4135 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4136 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4137 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4138 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4139 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4140 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 4141 | .KWH digital meter fro lighting section |
| 4142 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 4143 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 4144 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 4145 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 4146 | Supply and Laying of 3C X 35Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03456 |
| 4147 | Transformer Yard |
| 4148 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means (column footings) |
| 4149 | Sand filling as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge (column footings ) |
| 4150 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete (column footings ) |
| 4151 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(column footings ) |
| 4152 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(columns) |
| 4153 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(Plinth Beam ) |
| 4154 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours)BLD-CSTN-10-3 |
| 4155 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel barsFe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 4156 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 4157 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 4158 | Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 4159 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 4160 | PROVIDING 100KVA TRANSFORMER WITH ALL ACCESSORIESatexisting CW at Champavathi River to existing 400 KL GLSR zone-VI at Naidu colony and Proposed 300 KL ELSR at zone VII |
| 4161 | Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 4162 | Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 4163 | Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 4164 | Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 4165 | Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 4166 | Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 4167 | Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 4168 | Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 4169 | Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 4170 | A) Earth Electrodes |
| 4171 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 4172 | C) Epoxy insulators |
| 4173 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 4174 | Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.Makes : As per list of recommended brands as category I. MAT-04042 a100KVA |
| 4175 | 1. Quantity : 1 |
| 4176 | 2. Rated KVA :100 KVA |
| 4177 | 3. Service & Location: Continuous Outdoor Distribution Transformer |
| 4178 | 4. Mounting : Plinth. |
| 4179 | 5. Wound : CopperDouble wound |
| 4180 | 6. Type :Core type oil immersed |
| 4181 | 7. Cooling : ONAN |
| 4182 | 8. TempRise : 40⁰C in oil 45⁰C by resistance |
| 4183 | 9. Vector Group:Dyn 11 |
| 4184 | 10. Primary Connection :Delta |
| 4185 | 11. Nominal Voltage / Current : ______ |
| 4186 | 12. Highest system Voltage: 12000V |
| 4187 | 13. Primary Frequency :50 HZ +/- 3% |
| 4188 | 14. Number of Phases : 3 |
| 4189 | 15. Primary wires:3 |
| 4190 | 16. Secondary connection : Star |
| 4191 | 17. SecondaryVolts / Current :433V |
| 4192 | 18. Secondary phases :3 |
| 4193 | 19. Secondary wires:4 |
| 4194 | 20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7position (6 Steps) |
| 4195 | 21. Terminal arrangement. |
| 4196 | a.HV: HT terminal box as per the site condition. |
| 4197 | b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable |
| 4198 | 22. LV:One separate terminal for earthing. |
| 4199 | 23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats |
| 4200 | 24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats |
| 4201 | 25. Percentage Impedance at 75 deg C AT 4.5 |
| 4202 | 26. No load Current Less than 2% of full load Current |
| 4203 | 27. Standrad Fittings & Accessories. |
| 4204 | a. Rating and terminal marking plate: One |
| 4205 | b. Lifting Lugs:Two |
| 4206 | c. Off-circuit tap switch :One |
| 4207 | d. EarthingTerminals :Two |
| 4208 | e. Radiators ( Attachable):Adequate |
| 4209 | f.Explosion vent with Diaphragm :One |
| 4210 | g. Conservator with Drain plug:one |
| 4211 | h. Oil filling hole with cap :One |
| 4212 | i.Oil level indicator : One |
| 4213 | j.Dehydrating Silicagel Breather : One |
| 4214 | k. Terminal Arrangement: HV With Treminal Box |
| 4215 | l. Terminal Arrangement : LV Cable Box |
| 4216 | m. Separate Neutral Bushing: One |
| 4217 | n. Filter valve with blanking plate : One |
| 4218 | o. Drain cum filter valve with blanking plate : One |
| 4219 | p. Air release device : One |
| 4220 | q. Thermometer Pocket : One |
| 4221 | r. Four :Unidirectional flat rollers |
| 4222 | s. One :10Cm dial thermometer(Rigid stem type) |
| 4223 | Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 4224 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 4225 | Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 4226 | Incoming |
| 4227 | a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4228 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 4229 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 4230 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 4231 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 4232 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 4233 | g).3RYB Phase indication lamps with leds |
| 4234 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 4235 | Out-Going |
| 4236 | 630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4237 | 630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4238 | 630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4239 | 630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4240 | 630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 4241 | 630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 4242 | .KWH digital meter fro lighting section |
| 4243 | Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 4244 | Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 4245 | Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 4246 | 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 4247 | Supply and Laying of 3C X 35Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03456 |
| 4248 | Transformer Yard |
| 4249 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means (column footings) |
| 4250 | Sand filling as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge (column footings ) |
| 4251 | Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete (column footings ) |
| 4252 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(column footings ) |
| 4253 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(columns) |
| 4254 | Supply and placing of the M25 design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etc(Plinth Beam ) |
| 4255 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours)BLD-CSTN-10-3 |
| 4256 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel barsFe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 4257 | Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 4258 | Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 4259 | Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 4260 | supply and filling the transformer yard with 40mm HBG metal m/c |
| 4261 | Laying of 500mm dia.(8 mm thick plate) for Railway crossing |
| 4262 | Railway crossings / Road crossings / Canal crossings by trenchless technology tunneling work through specialized pipe jacking method in co-ordination with concerned authorities for as per approved drawings, installing to correct level gradient and alignment by hydralic pipe jacking technique complete including tunneling excavation drive and receive pits ,excavation and all machines tranaportation charges and other required materials but excluding cost of encasing pipe. |
| 4263 | Manufacture, Supply and Delivery of Spirally welded M.S Pipesand specials Conforming toIS 3589/2001 including in lining with Cement motor(1:2)12mm thick using 4 numbers of 6mm dia M.S.Rings at each end of the pipe and Out coating cement motor(1:3)30mm thick by shorcreting or Guniting duly providing wire mesh of size 50x50x3mmincluding cost of all materials,Labour charges, transportation to anywhere in AP, but including taxes & duties, etc. unit 1.00 Rmt |
| 4264 | Implementation of Environmental Management plan |
| 4265 | Monitoring Costs : Construction Phase(Two years) |
| 4266 | Air Quality Monitoring (4 Monitoring station) once in a month for three seasons during the construction period at Infiltration Galleries, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 4267 | Noiselevel(4Monitoringstation)onceinamonthforthree seasonsduring the constructionperiod at Infiltration Galleries, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 4268 | Water Quality Monitoring surface / ground(4 Monitoring station)once in a month for three seasons during theconstructionperiod at Infiltration Galleries, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 4269 | Construction of Clear Water SCADA Room 8.00 x 12.00 Size. |
| 4270 | Earthwork excavation by Manuallyin all types of soilsfor structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification |
| 4271 | Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification |
| 4272 | Laying Cement concrete (1:4:8)using 40mm nominal size HBG metal M/C including cost and conveyance of all materials from approved quarry, machine mixing, vibrating, laying, levelling, ramming, curing and labour charges etc., complete. |
| 4273 | Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification |
| 4274 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix unit 1.00cumfor Bed. |
| 4275 | Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix unit 1.00cumFor Side Walls of Septic Tank. 300mm |
| 4276 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum (Footings) |
| 4277 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum (Pedastals around Columns) |
| 4278 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum (Columns Up to plinth) |
| 4279 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum(Plinth Beams ) |
| 4280 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum (Columns ) |
| 4281 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cumBeams) |
| 4282 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum (Lintels) |
| 4283 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum(Sunshades) |
| 4284 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum (Staircase) |
| 4285 | Supply and placing of the M25 design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc -unit 1.00cum(RCC Slab 150mm thick) |
| 4286 | Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT)steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification |
| 4287 | Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of workand as per Technical Specification |
| 4288 | Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of workand as per Technical Specification First Floor |
| 4289 | Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification- Outside |
| 4290 | Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification.- Inside |
| 4291 | Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work and as per Technical Specification- Ceiling |
| 4292 | Flooring with ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials as per the technical specification |
| 4293 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification |
| 4294 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification |
| 4295 | Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification- Ceiling |
| 4296 | Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 4297 | Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6\" pitch complete for finished item of work as per the technical speciification Windows: Double shutter 3\"-0\" x 4\"-0\" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm. |
| 4298 | Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 4299 | Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 4300 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complete for light, bell , fan and exhaust fan points in non - residential building |
| 4301 | Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 4302 | supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 4303 | supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 4304 | supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 4305 | Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 4306 | Supply and fixing TPN Distribution board with IP-30 protection suitable for 3 phase ELCB / RCCB / FP Isolator as incomer and 10kA SP MCBs as outing going including internal connection and labour charges for surface / flush mounting etc., complete.BLD-ELEC-4.4.3 |
| 4307 | Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 4308 | Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 4309 | Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs. |
| 4310 | Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 4311 | Supply and fixing of 16A 3/2 pin flush type wall plug modular socket with shutter and 16A modular switche controll on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete. Makes of Switches : GM G Home /Anchor Penta Cherry / Gold Madel Olive / Million Zoom / Great White |
| 4312 | Supply of 2.0 TR 5 Star capable of delivering 24000 BTU/ hr and above with operating on refrigerant R-32 / R-410A AC unit with high wall mounted indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 3 core copper flexible cable including cordless remote control etc.complete as per technical specification. |
| 4313 | Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 4314 | Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of work |
| 4315 | Supplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 30mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work |
| 4316 | Supplying and fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit complete for finished item of work for all floors |
| 4317 | Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 4318 | Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 4319 | Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 4320 | Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 4321 | Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 4322 | S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete 25 mm dia nominal bore -from tank to jn forof individual lines and inlet |
| 4323 | S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete 20 mm dia nominal bore -fromjn forof individual lines to toilets |
| 4324 | S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete 15 mm dia nominal bore -for internal |
| 4325 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 4326 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 4327 | GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 4328 | S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 4329 | S& F GI union Ist Quality12.70mm |
| 4330 | S& F GI union Ist Quality 19.05mm |
| 4331 | S& F GI union Ist Quality 25.40mm |
| 4332 | Hiring of vehicles for 24 months on execution period. 1 no 24 months 35000/- per month |
| 4333 | Hiring of vehicles for 24 months on execution period. 1 no 24 months 35000/- per month |
| 4334 | Distribution System |
| 4335 | Laying new Distribution linesZone-I |
| 4336 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches By Mechanical Means |
| 4337 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches Manual Means |
| 4338 | Providing bedding with sandfor pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge |
| 4339 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 110 mm Dia |
| 4340 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 160mm dia. |
| 4341 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 200mm dia. |
| 4342 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S250mm dia. |
| 4343 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 110mm dia. |
| 4344 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160mm dia. |
| 4345 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160 mm dia for Air TEEs |
| 4346 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck200mm dia. |
| 4347 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 200 mm dia for Air TEEs |
| 4348 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250mm dia. |
| 4349 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Air TEEs |
| 4350 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia. |
| 4351 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia for bulk flow meter |
| 4352 | b) MS Flanges |
| 4353 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 110mm dia. |
| 4354 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160mm dia. |
| 4355 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160 mm dia for Air TEEs |
| 4356 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200mm dia. |
| 4357 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200 mm dia for Air TEEs |
| 4358 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250mm dia. |
| 4359 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250 mm dia for Air TEEs |
| 4360 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm Diia |
| 4361 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm dia for bulk flow meter |
| 4362 | c) End Caps |
| 4363 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 110mm dia. |
| 4364 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 160mm dia. |
| 4365 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 200mm dia. |
| 4366 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 250 mm dia |
| 4367 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 110X125 mmdia |
| 4368 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 125x140 mm dia |
| 4369 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 140x160 mm dia |
| 4370 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 160x180 mm dia |
| 4371 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers180x200 mm dia |
| 4372 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 200x225 mm dia |
| 4373 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 225x250 mm dia |
| 4374 | e) TEES |
| 4375 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 110mm dia. |
| 4376 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 160mm dia. |
| 4377 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES200mm dia. |
| 4378 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 250mm dia. |
| 4379 | F) Bends |
| 4380 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 110mm dia. |
| 4381 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 160mm dia. |
| 4382 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 200mm dia. |
| 4383 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 250mm dia. |
| 4384 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 110mm dia. |
| 4385 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 160mm dia. |
| 4386 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 200mm dia. |
| 4387 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete250mm dia. |
| 4388 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities. 100X2.00m on 110 dia mains for scours |
| 4389 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100X2.00m on 160 dia mains for scours |
| 4390 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities100x1.00m long DF pipes for sluice valves |
| 4391 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150X2.00mon 200 mm dia mains for scours |
| 4392 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x1.00m long DF pipes for sluice valves |
| 4393 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x1.00m long DF pipes for sluice valves |
| 4394 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x1.00m long DF pipes for sluice valves |
| 4395 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for sluice valves |
| 4396 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for bulk flow meter |
| 4397 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia deck foot bends |
| 4398 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150 mm dia deck foot bends |
| 4399 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia semicircular bends |
| 4400 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150 mm dia semicircular bends |
| 4401 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x150x80 mm DIDF TEE for air valves |
| 4402 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x200x80 mm DIDF TEE for air valves |
| 4403 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 100 mm distrubution |
| 4404 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 150mm dia for distrubution |
| 4405 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 200mm dia for distrubution |
| 4406 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 250mm dia for distrubution |
| 4407 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 300mm dia for distrubution |
| 4408 | for scour |
| 4409 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon 110 mmdia mains |
| 4410 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon160 mm dia mains |
| 4411 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 150 mm dia on 200 mm dia lines |
| 4412 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 160 mm pipe |
| 4413 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 200 mm pipe |
| 4414 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves.100 mm distrubution |
| 4415 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 150mm dia for distrubution |
| 4416 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 200mm dia for distrubution |
| 4417 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 250mm dia for distrubution |
| 4418 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 300mm dia for distrubution |
| 4419 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 350 mm dia for bulk flow meter |
| 4420 | for scour |
| 4421 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 100mm diaon 110 mmdia mains |
| 4422 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour100mm diaon160 mm dia mains |
| 4423 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 150 mm dia on 200 mm dia lines |
| 4424 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 mm dia on 150,250,315,355and 400 mm pipes |
| 4425 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work100 mm distrubution |
| 4426 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work150mm dia for distrubution |
| 4427 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work200mm dia for distrubution |
| 4428 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work250mm dia for distrubution |
| 4429 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work300mm dia for distrubution |
| 4430 | for scour |
| 4431 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for Scour 100mm diaon 110 mmdia mains |
| 4432 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work For Scour 100mm diaon160 mm dia mains |
| 4433 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for scour 150 mm dia on 200 mm dia lines |
| 4434 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 160 mm pipe |
| 4435 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 200 mm pipe |
| 4436 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80mm dia 250 mm pipe |
| 4437 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 110 dia mains for scours |
| 4438 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 160 dia mains for scours |
| 4439 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100x1.00m long DF pipes for sluice valves |
| 4440 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100 mm dia deck foot bends |
| 4441 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours100 mm dia semicircular bends |
| 4442 | 150 mm dia |
| 4443 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 150X2.00mon 200 mm dia mains for scours |
| 4444 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x1.00m long DF pipes for sluice valves |
| 4445 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150 mm dia deck foot bends |
| 4446 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150 mm dia semicircular bends |
| 4447 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x150x80 mm DIDF TEE for air valves |
| 4448 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x200x80 mm DIDF TEE for air valves |
| 4449 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x1.00m long DF pipes for sluice valves |
| 4450 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x250x80 mm DIDF TEE for air valves |
| 4451 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for sluice valves |
| 4452 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for sluice valves |
| 4453 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for bulk flow meter |
| 4454 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85. 80 mm dia |
| 4455 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 100 mm dia |
| 4456 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150 mm dia |
| 4457 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 200 mm dia |
| 4458 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250 mm dia |
| 4459 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 300 mm dia |
| 4460 | Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4461 | Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4462 | Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4463 | Filling crushur stone dustin pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 4464 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 4465 | Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportationand CED and ST etc,. complete. 350 mm DI K7 |
| 4466 | Lowering C.I. / D.I.Pipes (all classes) and specials (fittings)carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) 350mm DI K7 |
| 4467 | Jointing CI /DI pipes & fittings with s/s ends including cost of piglead, Spun yarn and sundries such as cost of fuel for melting lead,filling with water with lead up to 500m and testing to requiredpressure complete. (Reference to specifications. BISNo.3114/94/12288:1997) |
| 4468 | Zone-II Distribution system |
| 4469 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches By Mechanical Means |
| 4470 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches Manual Means |
| 4471 | Providing bedding with sandfor pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge |
| 4472 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 110 mm Dia |
| 4473 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 160mm dia. |
| 4474 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 200mm dia. |
| 4475 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S250mm dia. |
| 4476 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S315mm dia. |
| 4477 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 110mm dia. |
| 4478 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160mm dia. |
| 4479 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160 mm dia for Air TEEs |
| 4480 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250mm dia. |
| 4481 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Air TEEs |
| 4482 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Bulk flow meter |
| 4483 | b) MS Flanges |
| 4484 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 110mm dia. |
| 4485 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160mm dia. |
| 4486 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160 mm dia for Air TEEs |
| 4487 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250mm dia. |
| 4488 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250 mm dia for Air TEEs |
| 4489 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250 mm dia for bulk flow meter |
| 4490 | c) End Caps |
| 4491 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 110mm dia. |
| 4492 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 110X125 mmdia |
| 4493 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 125x140 mm dia |
| 4494 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 140x160 mm dia |
| 4495 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 160x180 mm dia |
| 4496 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers180x200 mm dia |
| 4497 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 200x225 mm dia |
| 4498 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 225x250 mm dia |
| 4499 | e) TEES |
| 4500 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 110mm dia. |
| 4501 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 160mm dia. |
| 4502 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES200mm dia. |
| 4503 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 250mm dia. |
| 4504 | F) Bends |
| 4505 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 110mm dia. |
| 4506 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 160mm dia. |
| 4507 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 250mm dia. |
| 4508 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 110mm dia. |
| 4509 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 160mm dia. |
| 4510 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 200mm dia. |
| 4511 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete250mm dia. |
| 4512 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete315mm dia. |
| 4513 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities. 100X2.00m on 110 dia mains for scours |
| 4514 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities100x1.00m long DF pipes for sluice valves |
| 4515 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x1.00m long DF pipes for sluice valves |
| 4516 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x1.00m long DF pipes for sluice valves |
| 4517 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x1.00m long DF pipes for bulkflow meter |
| 4518 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia deck foot bends |
| 4519 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia semicircular bends |
| 4520 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x150x80 mm DIDF TEE for air valves |
| 4521 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x250x80 mm DIDF TEE for air valves |
| 4522 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 100 mm distrubution |
| 4523 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 150mm dia for distrubution |
| 4524 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 250mm dia for distrubution |
| 4525 | for scour |
| 4526 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon 110 mmdia mains |
| 4527 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 160 mm pipe |
| 4528 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 250 mm pipe |
| 4529 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves.100 mm distrubution |
| 4530 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 150mm dia for distrubution |
| 4531 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 250mm dia for distrubution |
| 4532 | for scour |
| 4533 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 100mm diaon 110 mmdia mains |
| 4534 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 mm dia on 150,250,315,355and 400 mm pipes |
| 4535 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work100 mm distrubution |
| 4536 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work150mm dia for distrubution |
| 4537 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work250mm dia for distrubution |
| 4538 | for scour |
| 4539 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for Scour 100mm diaon 110 mmdia mains |
| 4540 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 160 mm pipe |
| 4541 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80mm dia 250 mm pipe |
| 4542 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 110 dia mains for scours |
| 4543 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100x1.00m long DF pipes for sluice valves |
| 4544 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100 mm dia deck foot bends |
| 4545 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours100 mm dia semicircular bends |
| 4546 | 150 mm dia |
| 4547 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x1.00m long DF pipes for sluice valves |
| 4548 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x150x80 mm DIDF TEE for air valves |
| 4549 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x250x80 mm DIDF TEE for air valves |
| 4550 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for sluice valves |
| 4551 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for bulk flow meter |
| 4552 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85. 80 mm dia |
| 4553 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 100 mm dia |
| 4554 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150 mm dia |
| 4555 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250 mm dia |
| 4556 | Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4557 | Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4558 | Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4559 | Filling crushur stone dustin pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 4560 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 4561 | Zone- III Distribution system |
| 4562 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches By Mechanical Means |
| 4563 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches Manual Means |
| 4564 | Providing bedding with sandfor pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge |
| 4565 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 110 mm Dia |
| 4566 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 160mm dia. |
| 4567 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 200mm dia. |
| 4568 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S250mm dia. |
| 4569 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 110mm dia. |
| 4570 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160mm dia. |
| 4571 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160 mm dia for Air TEEs |
| 4572 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia. |
| 4573 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia. AIR TEES |
| 4574 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia for bulk flow meter |
| 4575 | b) MS Flanges |
| 4576 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 110mm dia. |
| 4577 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160mm dia. |
| 4578 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160 mm dia for Air TEEs |
| 4579 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm Diia |
| 4580 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm Dia Air TEES |
| 4581 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm dia for bulk flow meter |
| 4582 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 110mm dia. |
| 4583 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 110X125 mmdia |
| 4584 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 125x140 mm dia |
| 4585 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 140x160 mm dia |
| 4586 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 160x180 mm dia |
| 4587 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers180x200 mm dia |
| 4588 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 250x280 mm dia |
| 4589 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 280x315 mm dia |
| 4590 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 110mm dia. |
| 4591 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 160mm dia. |
| 4592 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES200mm dia. |
| 4593 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 315 mm dia. |
| 4594 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 110mm dia. |
| 4595 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 160mm dia. |
| 4596 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 315 mm dia. |
| 4597 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 110mm dia. |
| 4598 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 160mm dia. |
| 4599 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 200mm dia. |
| 4600 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete250mm dia. |
| 4601 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities. 100X2.00m on 110 dia mains for scours |
| 4602 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100X2.00m on 160 dia mains for scours |
| 4603 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities100x1.00m long DF pipes for sluice valves |
| 4604 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x1.00m long DF pipes for sluice valves |
| 4605 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for sluice valves |
| 4606 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for bulk flow meter |
| 4607 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia deck foot bends |
| 4608 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia semicircular bends |
| 4609 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x150x80 mm DIDF TEE for air valves |
| 4610 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x300x80 mm DIDF TEE for air valves |
| 4611 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 100 mm distrubution |
| 4612 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 150mm dia for distrubution |
| 4613 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 300mm dia for distrubution |
| 4614 | for scour |
| 4615 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon 110 mmdia mains |
| 4616 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon160 mm dia mains |
| 4617 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 160 mm pipe |
| 4618 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 315 mm pipe |
| 4619 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves.100 mm distrubution |
| 4620 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 150mm dia for distrubution |
| 4621 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 300mm dia for distrubution |
| 4622 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 350 mm dia for bulk flow meter |
| 4623 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 100mm diaon 110 mmdia mains |
| 4624 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour100mm diaon160 mm dia mains |
| 4625 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 mm dia on 150,250,315,355and 400 mm pipes |
| 4626 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work100 mm distrubution |
| 4627 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work150mm dia for distrubution |
| 4628 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work300mm dia for distrubution |
| 4629 | for scour |
| 4630 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for Scour 100mm diaon 110 mmdia mains |
| 4631 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work For Scour 100mm diaon160 mm dia mains |
| 4632 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 160 mm pipe |
| 4633 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 315 mm pipe |
| 4634 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 110 dia mains for scours |
| 4635 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 160 dia mains for scours |
| 4636 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100x1.00m long DF pipes for sluice valves |
| 4637 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100 mm dia deck foot bends |
| 4638 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours100 mm dia semicircular bends |
| 4639 | 150 mm dia |
| 4640 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x1.00m long DF pipes for sluice valves |
| 4641 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x150x80 mm DIDF TEE for air valves |
| 4642 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x300x80mm DIDF TEE for Air Valves |
| 4643 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for sluice valves |
| 4644 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for bulk flow meter |
| 4645 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85. 80 mm dia |
| 4646 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 100 mm dia |
| 4647 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150 mm dia |
| 4648 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 300 mm dia |
| 4649 | Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4650 | Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4651 | Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4652 | Filling crushur stone dustin pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 4653 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 4654 | Zone- IV Distribution system |
| 4655 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches By Mechanical Means |
| 4656 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches Manual Means |
| 4657 | Providing bedding with sandfor pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge |
| 4658 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 110 mm Dia |
| 4659 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 160mm dia. |
| 4660 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 200mm dia. |
| 4661 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 110mm dia. |
| 4662 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160mm dia. |
| 4663 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160 mm dia for Air TEEs |
| 4664 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250mm dia. |
| 4665 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Air TEEs |
| 4666 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Bulk flow meter |
| 4667 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 110mm dia. |
| 4668 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160mm dia. |
| 4669 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160 mm dia for Air TEEs |
| 4670 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250mm dia. |
| 4671 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250 mm dia for Air TEEs |
| 4672 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250 mm dia for bulk flow meter |
| 4673 | c) End Caps |
| 4674 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 110mm dia. |
| 4675 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 110X125 mmdia |
| 4676 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 125x140 mm dia |
| 4677 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 140x160 mm dia |
| 4678 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 160x180 mm dia |
| 4679 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers180x200 mm dia |
| 4680 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 200x225 mm dia |
| 4681 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 225x250 mm dia |
| 4682 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 110mm dia. |
| 4683 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 160mm dia. |
| 4684 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 250mm dia. |
| 4685 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 110mm dia. |
| 4686 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 160mm dia. |
| 4687 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 250mm dia. |
| 4688 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 110mm dia. |
| 4689 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 160mm dia. |
| 4690 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 200mm dia. |
| 4691 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities. 100X2.00m on 110 dia mains for scours |
| 4692 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities100x1.00m long DF pipes for sluice valves |
| 4693 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x1.00m long DF pipes for sluice valves |
| 4694 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x1.00m long DF pipes for sluice valves |
| 4695 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia deck foot bends |
| 4696 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia semicircular bends |
| 4697 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x150x80 mm DIDF TEE for air valves |
| 4698 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x250x80 mm DIDF TEE for air valves |
| 4699 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 100 mm distrubution |
| 4700 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 150mm dia for distrubution |
| 4701 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 250mm dia for distrubution |
| 4702 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon 110 mmdia mains |
| 4703 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 160 mm pipe |
| 4704 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 250 mm pipe |
| 4705 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves.100 mm distrubution |
| 4706 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 150mm dia for distrubution |
| 4707 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 250mm dia for distrubution |
| 4708 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 100mm diaon 110 mmdia mains |
| 4709 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 mm dia on 150,250,315,355and 400 mm pipes |
| 4710 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work100 mm distrubution |
| 4711 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work150mm dia for distrubution |
| 4712 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work250mm dia for distrubution |
| 4713 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for Scour 100mm diaon 110 mmdia mains |
| 4714 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 160 mm pipe |
| 4715 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80mm dia 250 mm pipe |
| 4716 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 110 dia mains for scours |
| 4717 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100x1.00m long DF pipes for sluice valves |
| 4718 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100 mm dia deck foot bends |
| 4719 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours100 mm dia semicircular bends |
| 4720 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x1.00m long DF pipes for sluice valves |
| 4721 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x150x80 mm DIDF TEE for air valves |
| 4722 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x250x80 mm DIDF TEE for air valves |
| 4723 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for sluice valves |
| 4724 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for Bulk flow meter |
| 4725 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85. 80 mm dia |
| 4726 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 100 mm dia |
| 4727 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150 mm dia |
| 4728 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250 mm dia |
| 4729 | Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4730 | Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4731 | Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4732 | Filling crushur stone dustin pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 4733 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 4734 | Zone- V Distribution system |
| 4735 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches By Mechanical Means |
| 4736 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches Manual Means |
| 4737 | Providing bedding with sandfor pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge |
| 4738 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 110 mm Dia |
| 4739 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 160mm dia. |
| 4740 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 200mm dia. |
| 4741 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 110mm dia. |
| 4742 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160mm dia. |
| 4743 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160 mm dia for Air TEEs |
| 4744 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck200mm dia. |
| 4745 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 200 mm dia for Air TEEs |
| 4746 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250mm dia. |
| 4747 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Air TEEs |
| 4748 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia. |
| 4749 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia for bulk flow meter |
| 4750 | b) MS Flanges |
| 4751 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 110mm dia. |
| 4752 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160mm dia. |
| 4753 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160 mm dia for Air TEEs |
| 4754 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200mm dia. |
| 4755 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200 mm dia for Air TEEs |
| 4756 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250mm dia. |
| 4757 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250 mm dia for Air TEEs |
| 4758 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm Diia |
| 4759 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm dia for bulk flow meter |
| 4760 | c) End Caps |
| 4761 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 110mm dia. |
| 4762 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 110X125 mmdia |
| 4763 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 125x140 mm dia |
| 4764 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 140x160 mm dia |
| 4765 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 160x180 mm dia |
| 4766 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers180x200 mm dia |
| 4767 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 200x225 mm dia |
| 4768 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 225x250 mm dia |
| 4769 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 250x280 mm dia |
| 4770 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 280x315 mm dia |
| 4771 | e) TEES |
| 4772 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 110mm dia. |
| 4773 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 160mm dia. |
| 4774 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES200mm dia. |
| 4775 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 250mm dia. |
| 4776 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 110mm dia. |
| 4777 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 160mm dia. |
| 4778 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 200mm dia. |
| 4779 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 250mm dia. |
| 4780 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 250mm dia. |
| 4781 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 110mm dia. |
| 4782 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 160mm dia. |
| 4783 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 200mm dia. |
| 4784 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities. 100X2.00m on 110 dia mains for scours |
| 4785 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100X2.00m on 160 dia mains for scours |
| 4786 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities100x1.00m long DF pipes for sluice valves |
| 4787 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x1.00m long DF pipes for sluice valves |
| 4788 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x1.00m long DF pipes for sluice valves |
| 4789 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x1.00m long DF pipes for sluice valves |
| 4790 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for sluice valves |
| 4791 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for bulk flow meter |
| 4792 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia deck foot bends |
| 4793 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia semicircular bends |
| 4794 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x150x80 mm DIDF TEE for air valves |
| 4795 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x200x80 mm DIDF TEE for air valves |
| 4796 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x250x80 mm DIDF TEE for air valves |
| 4797 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 100 mm distrubution |
| 4798 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 150mm dia for distrubution |
| 4799 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 200mm dia for distrubution |
| 4800 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 250mm dia for distrubution |
| 4801 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 300mm dia for distrubution |
| 4802 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon 110 mmdia mains |
| 4803 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon160 mm dia mains |
| 4804 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 160 mm pipe |
| 4805 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 200 mm pipe |
| 4806 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 200 mm pipe |
| 4807 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves.100 mm distrubution |
| 4808 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 150mm dia for distrubution |
| 4809 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 200mm dia for distrubution |
| 4810 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 250mm dia for distrubution |
| 4811 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 300mm dia for distrubution |
| 4812 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 350 mm dia for bulk flow meter |
| 4813 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 100mm diaon 110 mmdia mains |
| 4814 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour100mm diaon160 mm dia mains |
| 4815 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 mm dia on 150,250,315,355and 400 mm pipes |
| 4816 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work100 mm distrubution |
| 4817 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work150mm dia for distrubution |
| 4818 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work200mm dia for distrubution |
| 4819 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work250mm dia for distrubution |
| 4820 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work300mm dia for distrubution |
| 4821 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for Scour 100mm diaon 110 mmdia mains |
| 4822 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work For Scour 100mm diaon160 mm dia mains |
| 4823 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 160 mm pipe |
| 4824 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 200 mm pipe |
| 4825 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80mm dia 250 mm pipe |
| 4826 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 110 dia mains for scours |
| 4827 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 160 dia mains for scours |
| 4828 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100x1.00m long DF pipes for sluice valves |
| 4829 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100 mm dia deck foot bends |
| 4830 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours100 mm dia semicircular bends |
| 4831 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x1.00m long DF pipes for sluice valves |
| 4832 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x150x80 mm DIDF TEE for air valves |
| 4833 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x200x80 mm DIDF TEE for air valves |
| 4834 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x1.00m long DF pipes for sluice valves |
| 4835 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x250x80 mm DIDF TEE for air valves |
| 4836 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for sluice valves |
| 4837 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for sluice valves |
| 4838 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for bulk flow meter |
| 4839 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85. 80 mm dia |
| 4840 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 100 mm dia |
| 4841 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150 mm dia |
| 4842 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 200 mm dia |
| 4843 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250 mm dia |
| 4844 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 300 mm dia |
| 4845 | Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4846 | Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4847 | Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4848 | Filling crushur stone dustin pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 4849 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 4850 | Zone- VIDistribution system |
| 4851 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches By Mechanical Means |
| 4852 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches Manual Means |
| 4853 | Providing bedding with sandfor pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge |
| 4854 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 110 mm Dia |
| 4855 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 160mm dia. |
| 4856 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 200mm dia. |
| 4857 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S250mm dia. |
| 4858 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S315mm dia. |
| 4859 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 110mm dia. |
| 4860 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160mm dia. |
| 4861 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160 mm dia for Air TEEs |
| 4862 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck200mm dia. |
| 4863 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 200 mm dia for Air TEEs |
| 4864 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Bulk flow meter |
| 4865 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 110mm dia. |
| 4866 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160mm dia. |
| 4867 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160 mm dia for Air TEEs |
| 4868 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200mm dia. |
| 4869 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200 mm dia for Air TEEs |
| 4870 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250mm dia. For bulk flow meter |
| 4871 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 110mm dia. |
| 4872 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 110X125 mmdia |
| 4873 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 125x140 mm dia |
| 4874 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 140x160 mm dia |
| 4875 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 160x180 mm dia |
| 4876 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers180x200 mm dia |
| 4877 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 200x225 mm dia |
| 4878 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 225x250 mm dia |
| 4879 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 250x280 mm dia |
| 4880 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 280x315 mm dia |
| 4881 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 110mm dia. |
| 4882 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 160mm dia. |
| 4883 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES200mm dia. |
| 4884 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 250mm dia. |
| 4885 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 315 mm dia. |
| 4886 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 110mm dia. |
| 4887 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 160mm dia. |
| 4888 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 200mm dia. |
| 4889 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 250mm dia. |
| 4890 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 110mm dia. |
| 4891 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 160mm dia. |
| 4892 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 200mm dia. |
| 4893 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete250mm dia. |
| 4894 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete315mm dia. |
| 4895 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities. 100X2.00m on 110 dia mains for scours |
| 4896 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities100x1.00m long DF pipes for sluice valves |
| 4897 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x1.00m long DF pipes for sluice valves |
| 4898 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x1.00m long DF pipes for sluice valves |
| 4899 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x1.00m long DF pipes for bulk flowmeter |
| 4900 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia deck foot bends |
| 4901 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia semicircular bends |
| 4902 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x150x80 mm DIDF TEE for air valves |
| 4903 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x200x80 mm DIDF TEE for air valves |
| 4904 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 100 mm distrubution |
| 4905 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 150mm dia for distrubution |
| 4906 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 200mm dia for distrubution |
| 4907 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon 110 mmdia mains |
| 4908 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 160 mm pipe |
| 4909 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 200 mm pipe |
| 4910 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves.100 mm distrubution |
| 4911 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 150mm dia for distrubution |
| 4912 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 200mm dia for distrubution |
| 4913 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 100mm diaon 110 mmdia mains |
| 4914 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 mm dia on 150,250,315,355and 400 mm pipes |
| 4915 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work100 mm distrubution |
| 4916 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work150mm dia for distrubution |
| 4917 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work200mm dia for distrubution |
| 4918 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for Scour 100mm diaon 110 mmdia mains |
| 4919 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 160 mm pipe |
| 4920 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 200 mm pipe |
| 4921 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 110 dia mains for scours |
| 4922 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100x1.00m long DF pipes for sluice valves |
| 4923 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100 mm dia deck foot bends |
| 4924 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours100 mm dia semicircular bends |
| 4925 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x1.00m long DF pipes for sluice valves |
| 4926 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x150x80 mm DIDF TEE for air valves |
| 4927 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x200x80 mm DIDF TEE for air valves |
| 4928 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x1.00m long DF pipes for sluice valves |
| 4929 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for bulk flowmeter |
| 4930 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85. 80 mm dia |
| 4931 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 100 mm dia |
| 4932 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150 mm dia |
| 4933 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 200 mm dia |
| 4934 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250 mm dia |
| 4935 | Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4936 | Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4937 | Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 4938 | Filling crushur stone dustin pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 4939 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 4940 | Zone- VIIDistribution system |
| 4941 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches By Mechanical Means |
| 4942 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches Manual Means |
| 4943 | Providing bedding with sandfor pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification anddirected by the Engineer - in - Charge |
| 4944 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 110 mm Dia |
| 4945 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 160mm dia. |
| 4946 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S 200mm dia. |
| 4947 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S250mm dia. |
| 4948 | Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking including all taxes etc. complete as per S.S315mm dia. |
| 4949 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 110mm dia. |
| 4950 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160mm dia. |
| 4951 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 160 mm dia for Air TEEs |
| 4952 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck200mm dia. |
| 4953 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 200 mm dia for Air TEEs |
| 4954 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250mm dia. |
| 4955 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 250 mm dia for Air TEEs |
| 4956 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia. |
| 4957 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia for Air TEES |
| 4958 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Pipe end Long Neck 315 mm dia for bulk flow meter |
| 4959 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 110mm dia. |
| 4960 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160mm dia. |
| 4961 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 160 mm dia for Air TEEs |
| 4962 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200mm dia. |
| 4963 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 200 mm dia for Air TEEs |
| 4964 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250mm dia. |
| 4965 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 250 mm dia for Air TEEs |
| 4966 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm Diia |
| 4967 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm dia for bulk flow meter |
| 4968 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.completeMS Flanges 315 mm dia for Air TEES |
| 4969 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete End Caps 110mm dia. |
| 4970 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 110X125 mmdia |
| 4971 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 125x140 mm dia |
| 4972 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 140x160 mm dia |
| 4973 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 160x180 mm dia |
| 4974 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers180x200 mm dia |
| 4975 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 200x225 mm dia |
| 4976 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 225x250 mm dia |
| 4977 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Reducers 250x280 mm dia |
| 4978 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 110mm dia. |
| 4979 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 160mm dia. |
| 4980 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES200mm dia. |
| 4981 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 250mm dia. |
| 4982 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete TEES 315mm dia. |
| 4983 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 110mm dia. |
| 4984 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 160mm dia. |
| 4985 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 200mm dia. |
| 4986 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 250mm dia. |
| 4987 | Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete Bends 315mm dia. |
| 4988 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 110mm dia. |
| 4989 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 160mm dia. |
| 4990 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete 200mm dia. |
| 4991 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete250mm dia. |
| 4992 | Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete315mm dia. |
| 4993 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities. 100X2.00m on 110 dia mains for scours |
| 4994 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100X2.00m on 160 dia mains for scours |
| 4995 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities100x1.00m long DF pipes for sluice valves |
| 4996 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x1.00m long DF pipes for sluice valves |
| 4997 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x1.00m long DF pipes for sluice valves |
| 4998 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x1.00m long DF pipes for sluice valves |
| 4999 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for sluice valves |
| 5000 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x1.00m long DF pipes for bulk flow meter |
| 5001 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia deck foot bends |
| 5002 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 100 mm dia semicircular bends |
| 5003 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 150x150x80 mm DIDF TEE for air valves |
| 5004 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 200x200x80 mm DIDF TEE for air valves |
| 5005 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 250x250x80 mm DIDF TEE for air valves |
| 5006 | Supply and delivery of DIPipes and fittings (Specials) confirming to specification No.I.S.No. 7181/1986, 5531/1988, 3950/1979 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities 300x300x80 mm DIDF TEE for air valves |
| 5007 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 100 mm distrubution |
| 5008 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 150mm dia for distrubution |
| 5009 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 200mm dia for distrubution |
| 5010 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 250mm dia for distrubution |
| 5011 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - 300mm dia for distrubution |
| 5012 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon 110 mmdia mains |
| 5013 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. PN16 - For Scour 100mm diaon160 mm dia mains |
| 5014 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 160 mm pipe |
| 5015 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 200 mm pipe |
| 5016 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 80 mm dia on 250 mm pipe |
| 5017 | Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions.All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN1680 mm dia on 315 mm pipe |
| 5018 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves.100 mm distrubution |
| 5019 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 150mm dia for distrubution |
| 5020 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 200mm dia for distrubution |
| 5021 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 250mm dia for distrubution |
| 5022 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 300mm dia for distrubution |
| 5023 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. 350 mm dia for bulk flow meter |
| 5024 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour 100mm diaon 110 mmdia mains |
| 5025 | Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. For scour100mm diaon160 mm dia mains |
| 5026 | Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. 80 mm dia on 150,250,315,355and 400 mm pipes |
| 5027 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work100 mm distrubution |
| 5028 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work150mm dia for distrubution |
| 5029 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work200mm dia for distrubution |
| 5030 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work250mm dia for distrubution |
| 5031 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work300mm dia for distrubution |
| 5032 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work for Scour 100mm diaon 110 mmdia mains |
| 5033 | Construction of sluice and scourValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work For Scour 100mm diaon160 mm dia mains |
| 5034 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 160 mm pipe |
| 5035 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80 mm dia on 200 mm pipe |
| 5036 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80mm dia 250 mm pipe |
| 5037 | Construction of AirValve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work80mm dia 315 mm pipe |
| 5038 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 110 dia mains for scours |
| 5039 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100X2.00m on 160 dia mains for scours |
| 5040 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100x1.00m long DF pipes for sluice valves |
| 5041 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours 100 mm dia deck foot bends |
| 5042 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 DIDF Pipes for scours100 mm dia semicircular bends |
| 5043 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x1.00m long DF pipes for sluice valves |
| 5044 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 150x150x80 mm DIDF TEE for air valves |
| 5045 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x200x80 mm DIDF TEE for air valves |
| 5046 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 200x1.00m long DF pipes for sluice valves |
| 5047 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x250x80 mm DIDF TEE for air valves |
| 5048 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 250x1.00m long DF pipes for sluice valves |
| 5049 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94300x300x80 mm DIDF TEE for air valves |
| 5050 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for sluice valves |
| 5051 | Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 300x1.00m long DF pipes for Bulkflow meter |
| 5052 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85. 80 mm dia |
| 5053 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 100 mm dia |
| 5054 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 150 mm dia |
| 5055 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 200 mm dia |
| 5056 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 250 mm dia |
| 5057 | Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 300 mm dia |
| 5058 | Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 5059 | Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 5060 | Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work. |
| 5061 | Filling crushur stone dustin pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 5062 | Construction ofun-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501 MORD. (CC pavement) |
| 5063 | Providing newHouse Service Connections at house hold side in earthen roads (MDPE 4mts) |
| 5064 | Providing and fixing of House Service connections into household compound from HDPE mains including Earthwork & Refillinga) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd.b) 1 No. of Flow Control valve SS 316 NRV 10 LPMc) 2 No. of Compression adaptor with one side compression end to suit 1/2 \"to1\"\"(15mmOD to25 mm OD)MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2\" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and \"O\" ring of NBR material, as per ISO 14236 standards with pressure rating PN16d) 2 No. ofDouble compression elbow to suit 1/2 \" to 1\"\" (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and \"O\" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 .e)MDPE PE80 Blue Pipe ofspecified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. ( Min 4.00 M length at House Hold side and Min 7.00 m length at Opp Side) and 1m 40mm UPVC pipe for Drain crossingf) 1 No PlasticBib Cockg) drilling of hoe in RCC / RR in compound wall h) holder clamps where ever requiredand as per Technical Specification |
| 5065 | Providing newHouse Service Connections at other side in earthen roads (MDPE Pipe 7 Mts) |
| 5066 | Providing and fixing of House Service connections into household compound from HDPE mains including Earthwork & Refillinga) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd.b) 1 No. of Flow Control valve SS 316 NRV 10 LPMc) 2 No. of Compression adaptor with one side compression end to suit 1/2 \"to1\"\"(15mmOD to25 mm OD)MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2\" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and \"O\" ring of NBR material, as per ISO 14236 standards with pressure rating PN16d) 2 No. ofDouble compression elbow to suit 1/2 \" to 1\"\" (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and \"O\" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 .e)MDPE PE80 Blue Pipe ofspecified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. ( Min 4.00 M length at House Hold side and Min 7.00 m length at Opp Side) and 1m 40mm UPVC pipe for Drain crossingf) 1 No PlasticBib Cockg) drilling of hoe in RCC / RR in compound wall h) holder clamps where ever requiredand as per Technical Specification |
| 5067 | Providing newHouse Service Connections at other side in CC&BT roads (MDPE Pipe 7 mts) |
| 5068 | Providing and fixing of House Service connections into household compound from HDPE mains including Earthwork & Refillinga) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd.b) 1 No. of Flow Control valve SS 316 NRV 10 LPMc) 2 No. of Compression adaptor with one side compression end to suit 1/2 \"to1\"\"(15mmOD to25 mm OD)MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2\" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and \"O\" ring of NBR material, as per ISO 14236 standards with pressure rating PN16d) 2 No. ofDouble compression elbow to suit 1/2 \" to 1\"\" (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and \"O\" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 .e)MDPE PE80 Blue Pipe ofspecified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. ( Min 4.00 M length at House Hold side and Min 7.00 m length at Opp Side) and 1m 40mm UPVC pipe for Drain crossingf) 1 No PlasticBib Cockg) drilling of hoe in RCC / RR in compound wall h) holder clamps where ever requiredand as per Technical Specification |
| 5069 | Providing newHouse Service Connections at HH side in CC&BT roads |
| 5070 | Providing and fixing of House Service connections into household compound from HDPE mains including Earthwork & Refillinga) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd.b) 1 No. of Flow Control valve SS 316 NRV 10 LPMc) 2 No. of Compression adaptor with one side compression end to suit 1/2 \"to1\"\"(15mmOD to25 mm OD)MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2\" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and \"O\" ring of NBR material, as per ISO 14236 standards with pressure rating PN16d) 2 No. ofDouble compression elbow to suit 1/2 \" to 1\"\" (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and \"O\" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 .e)MDPE PE80 Blue Pipe ofspecified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. ( Min 4.00 M length at House Hold side and Min 7.00 m length at Opp Side) and 1m 40mm UPVC pipe for Drain crossingf) 1 No PlasticBib Cockg) drilling of hoe in RCC / RR in compound wall h) holder clamps where ever requiredand as per Technical Specification |
| 5071 | Hiring of vehicles for 24 months on execution period. 1 no 24 months 35000/- per month |
| 5072 | Hiring of vehicles for 24 months on execution period. 1 no 24 months 35000/- per month |
| 5073 | Providing Instrumentation, Automation of the Pumping systems , Reservoir management &SCADA for Nellimarla Nagar Panchayat. |
| 5074 | Instrumantation and Automation of the Pumping System: |
| 5075 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer., For Clear Water Pumping Station-1 as per the above specification |
| 5076 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer., For Clear Water Pumping Station-2 as per the above specification |
| 5077 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer For Clear Water Pumping Station-3 as per the above specification |
| 5078 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer For Clear Water Pumping Station-4 as per the above specification |
| 5079 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. For Clear Water Pumping Station-1 as per the above specification |
| 5080 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.For Clear Water Pumping Station-2 as per the above specification |
| 5081 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.For Clear Water Pumping Station-3 as per the above specification |
| 5082 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. For Clear Water Pumping Station-4 as per the above specification |
| 5083 | Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer .DN 100 - PN 16 pump control valve for Clear Water Pumping Station-1 as per the above specification |
| 5084 | Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer DN 100 - PN 16 pump control valve for Clear Water Pumping Station-2 as per the above specification |
| 5085 | Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer DN 100 - PN 16 pump control valve for Clear Water Pumping Station-3 as per the above specification |
| 5086 | Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer DN 100 - PN 16 pump control valve for Clear Water Pumping Station-4 as per the above specification |
| 5087 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 150MM Dia Above Specification.outlet of Clear Water Pumping Station-1 at Champavati river |
| 5088 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification.outlet of Clear Water Pumping Station-2 at Champavati river |
| 5089 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification.outlet of Clear Water Pumping Station-3 at Champavati river |
| 5090 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification.outlet of Clear Water Pumping Station-4 at Champavati river |
| 5091 | Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Clear Water outlet-1 of Water Treatment plant |
| 5092 | Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Clear Water outlet-2 of Water Treatment plant |
| 5093 | Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Clear Water outlet-3 of Water Treatment plant |
| 5094 | Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Clear Water outlet-4 of Water Treatment plant |
| 5095 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Clear Water outlet-1 of Water Treatment plant |
| 5096 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-2 of Water Treatment plant |
| 5097 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-3 of Water Treatment plant |
| 5098 | Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-4 of Water Treatment plant |
| 5099 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.Clear Water outlet-1 of Water Treatment plant |
| 5100 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-2 of Water Treatment plant |
| 5101 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-3 of Water Treatment plant |
| 5102 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-4 of Water Treatment plant |
| 5103 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Clear Water outlet-1 of Water Treatment plant |
| 5104 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Clear Water outlet-1 of Water Treatment plant |
| 5105 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-3 of Water Treatment plant |
| 5106 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes Clear Water outlet-4 of Water Treatment plant |
| 5107 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Clear Water outlet-1 of Water Treatment plant |
| 5108 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Clear Water outlet-2 of Water Treatment plant |
| 5109 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Clear Water outlet-3 of Water Treatment plant |
| 5110 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Clear Water outlet-4 of Water Treatment plant |
| 5111 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. outlet ofclear water pumping station-1 |
| 5112 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. outlet ofclear water pumping station-2 |
| 5113 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.outlet ofclear water pumping station-3 |
| 5114 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. outlet ofclear water pumping station-4 |
| 5115 | Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer.For Clear Water Pumping Station-1 as per the above specification |
| 5116 | Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. For Clear Water Pumping Station-2 as per the above specification |
| 5117 | Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. For Clear Water Pumping Station-3 as per the above specification |
| 5118 | Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. For Clear Water Pumping Station-4 as per the above specification |
| 5119 | Logic for RTU opeartaions:1. RTU panel for local operaion of the pumps in manual and Auto Mode.2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables.3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves.5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned.6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves.7. In manual opeartion, all the equiment can be run through PLC panel by individual operations.8.The RTU connected with SCADA for remote monitoring and operation.9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge. |
| 5120 | Reservoir Inlet management |
| 5121 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.100MM Dia Above Specification. Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5122 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.100MM Dia Above SpecificationInlet of 250 KL Existing ELSR at Gandhi nagar |
| 5123 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.100MM Dia Above SpecificationInlet of 120 KL Existing ELSR at Saali veedhi |
| 5124 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.100MM Dia Above SpecificationInlet of 200 KL Existing ELSR at Kondapeta |
| 5125 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.100MM Dia Above Specification Inlet of 130 KL Existing GLSR at Panchayat office |
| 5126 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.100MM Dia Above Specification Inlet of 400 KL Existing GLSR at Naidu colony |
| 5127 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.100MM Dia Above Specification Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5128 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. 150MM Dia Above Specification. Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5129 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification. Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5130 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification.Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5131 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification.Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5132 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification. Inlet of 200 KL Existing ELSR at Kondapeta |
| 5133 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification Inlet of 130 KL Existing GLSR at Panchayat office |
| 5134 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above SpecificationInlet of 400 KL Existing GLSR at Naidu colony |
| 5135 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. 100MM Dia Above Specification Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5136 | Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.150MM Dia Above Specification. Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5137 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 100MM Dia Above Specification.Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5138 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 100MM Dia Above Specification. Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5139 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 100MM Dia Above Specification.Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5140 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 100MM Dia Above Specification Inlet of 200 KL Existing ELSR at Kondapeta |
| 5141 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 100MM Dia Above Specification Inlet of 130 KL Existing GLSR at Panchayat office |
| 5142 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 100MM Dia Above Specification Inlet of 400 KL Existing GLSR at Naidu colony |
| 5143 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 100MM Dia Above Specification Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5144 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 150MM Dia Above Specification.Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5145 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 100MM Dia Above Specification.Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5146 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 100MM Dia Above Specification Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5147 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 100MM Dia Above SpecificationInlet of 120 KL Existing ELSR at Saali veedhi |
| 5148 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 100MM Dia Above SpecificationInlet of 200 KL Existing ELSR at Kondapeta |
| 5149 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 100MM Dia Above SpecificationInlet of 130 KL Existing GLSR at Panchayat office |
| 5150 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 100MM Dia Above SpecificationInlet of 400 KL Existing GLSR at Naidu colony |
| 5151 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 100MM Dia Above SpecificationInlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5152 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 150MM Dia Above Specification .Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5153 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5154 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5155 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5156 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 200 KL Existing ELSR at Kondapeta |
| 5157 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 130 KL Existing GLSR at Panchayat office |
| 5158 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 400 KL Existing GLSR at Naidu colony |
| 5159 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5160 | Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5161 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5162 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5163 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5164 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 200 KL Existing ELSR at Kondapeta |
| 5165 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 130 KL Existing GLSR at Panchayat office |
| 5166 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 400 KL Existing GLSR at Naidu colony |
| 5167 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5168 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5169 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5170 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5171 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5172 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 200 KL Existing ELSR at Kondapeta |
| 5173 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 130 KL Existing GLSR at Panchayat office |
| 5174 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 400 KL Existing GLSR at Naidu colony |
| 5175 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5176 | Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5177 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5178 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., office Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5179 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., office Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5180 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., office Inlet of 200 KL Existing ELSR at Kondapeta |
| 5181 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., office Inlet of 130 KL Existing GLSR at Panchayat office |
| 5182 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., office Inlet of 400 KL Existing GLSR at Naidu colony |
| 5183 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., office Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5184 | Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., office Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5185 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5186 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5187 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5188 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. Inlet of 200 KL Existing ELSR at Kondapeta |
| 5189 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. Inlet of 130 KL Existing GLSR at Panchayat office |
| 5190 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. Inlet of 400 KL Existing GLSR at Naidu colony |
| 5191 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5192 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5193 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5194 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5195 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5196 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 200 KL Existing ELSR at Kondapeta |
| 5197 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 130 KL Existing GLSR at Panchayat office |
| 5198 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 400 KL Existing GLSR at Naidu colony |
| 5199 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5200 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5201 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5202 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5203 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5204 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 200 KL Existing ELSR at Kondapeta |
| 5205 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 130 KL Existing GLSR at Panchayat office |
| 5206 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 400 KL Existing GLSR at Naidu colony |
| 5207 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5208 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5209 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5210 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 250 KL Existing ELSR at Gandhi nagar |
| 5211 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 120 KL Existing ELSR at Saali veedhi |
| 5212 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 200 KL Existing ELSR at Kondapeta |
| 5213 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 130 KL Existing GLSR at Panchayat office |
| 5214 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer v Inlet of 400 KL Existing GLSR at Naidu colony |
| 5215 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5216 | Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5217 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5218 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5219 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officerInlet of 120 KL Existing ELSR at Saali veedhi |
| 5220 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 200 KL Existing ELSR at Kondapeta |
| 5221 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 130 KL Existing GLSR at Panchayat office |
| 5222 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 400 KL Existing GLSR at Naidu colony |
| 5223 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5224 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5225 | Local SCADA Control Sation: |
| 5226 | Establishment of HARDWARE for Individual Local Control Station at Individual ULB :: |
| 5227 | Supply,erection, testing, commissioning of Hard ware for the SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter managementwhere the instrumantation and automation developed under this project and synchornization by deploying the followingcomponents including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. |
| 5228 | Desktop PC Station with specification of I7Processor, 8 GB Ram, ,512 GB SSD,Licensed OS, 21\" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL |
| 5229 | 55\" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screenswith required cables and connectors etc., complete. |
| 5230 | Modem with specifications of Fibre Port having ILL, PON &Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider |
| 5231 | 3 KVA Stabilizer with specifications of 220 V.ACInput/ 220 V.AC output, necessary terminal wires etc., complete complete |
| 5232 | 3 KVA online ups with specifications of 220 V.ACInput/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank,make ofVertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete |
| 5233 | 3 in one on line B/W A4 Lazer Jet printer |
| 5234 | Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication |
| 5235 | Establishment of Local SCADA station at Nellimarla Municipality with the above specifications. |
| 5236 | Development of Softwares for Individual Local Control Station at Individual ULB :: |
| 5237 | Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer |
| 5238 | Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user) |
| 5239 | Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. |
| 5240 | Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customerat the time of commissioning |
| 5241 | Develop, Supply, install and commissioning of Anroid & IO\"s application for data monitoring by through Mobi-APP as required by the customerat the time of commissioningcomplete |
| 5242 | Establishment of Local SCADA station atNellimarla Municipality with the above specifications. |
| 5243 | Providing DMA management for 24 x7 water supply in Nellimarla Nagar Panchayat |
| 5244 | supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.200MM Dia Above Specification.Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5245 | Supply and deliveryof Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.200MM Dia Above Specification. Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5246 | Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer 200MM Dia Above Specification.Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5247 | Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. 200MM Dia Above Specification. Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5248 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5249 | Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5250 | Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5251 | Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5252 | Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5253 | Providing, Installing and satisfactory field testing of Self Powered Presuure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Pressure points at Highest Point, Lowest Point & Furthest Point Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5254 | Providing, Installing and satisfactory field testing of Self Powered Presuure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Pressure points at Highest Point, Lowest Point & Furthest Point Under 500 KL ELSR at Jarajapupeta High school Zone-I |
| 5255 | Providing, Installing and satisfactory field testing of Self Powered Presuure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Pressure points at Highest Point, Lowest Point & Furthest Point Under 300 KL ELSR at CBN Colony Zone-IV |
| 5256 | Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.Inlet of DMA-1 under 200 KL ELSR at Kondapeta zone-2A |
| 5257 | Providing AMI Water Meter Management in Nellimarla Nagar Panchayat |
| 5258 | AMI Water Meter Management. |
| 5259 | Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-A.DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area |
| 5260 | Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoTin every 24 Hours without fail through the provider registered inDOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication)The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warrantiesand submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-B Under DMA-1under 200 KL ELSR at ELSR at Kondapeta zone-2A with above specifications |
| 5261 | Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer. |
| 5262 | OPERATION & MAINTENANCE COST (ExcludingEnergy charges ) forSeven Years including Two years Defect Liability Period .O & M Cost Excluding Power charges in Nellimarla NP |
| 5263 | Personal required for operating Intake/Offtake well/Pump houses |
| 5264 | Operator |
| 5265 | Personal required at operating Clear water rising mains |
| 5266 | Fitter/Helper |
| 5267 | Personal required at operating Service reservoirs |
| 5268 | Watch man |
| 5269 | Personal required at operating distribution system |
| 5270 | Fitter/Helper |
| 5271 | Consumables for 7 years |
| 5272 | A) Chlorine gas for Disinfection @ 3 mg/Lt |
| 5273 | Repairs to pumpsets & Water pipe lines(2 years after execution period) |
| 5274 | i) Replacement of bearings of pumpsets |
| 5275 | ii) Replacement of sleeves |
| 5276 | iv) Raw Water Motors |
| 5277 | Clear Water Motors |
| 5278 | iv)Replacement of glands of sluice valves |
| 5279 | v) Replacements of balls of Air valves |
| 5280 | vi) Greease |
| 5281 | vii) Gland Packing |
| 5282 | Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete |
| 5283 | 250 mm HDPE Pipes |
| 5284 | 200 mm HDPE Pipes |
| 5285 | 160 mm HDPE Pipes |
| 5286 | 110 mm HDPE Pipes |
| 5287 | Providing for Implementation of Environmental and Social Management Plan for Nellimarla NP during Operation phase |
| 5288 | Air Quality Monitoring (4 Monitoring station) once in a month for three seasons during the construction period at Infiltration Galleries, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 5289 | Noiselevel(4Monitoringstation)onceinamonthforthree seasonsduring the constructionperiodat Infiltration Galleries, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 5290 | Water Quality Monitoring surface / ground(4 Monitoring station)once in a month for three seasons during theconstructionperiod at Infiltration Galleries, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 5291 | Compensatory plantation andthree years maintenance (Compensatory afforestation ratio is 1:5) |
| 5292 | Sprinkling of wateronce in a day fortwo years (excluding rainy days):500 days @ Rs.1000/trip |
| 5293 | Operation & Maintenance cost Local SCADA at ULB |
| 5294 | Jr. Service Engineer(Diploma Engineer)Rate as per Labour Rates LAB-00127 of CSSR 2025-26 |
| 5295 | Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-26 |
| 5296 | Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 |
| 5297 | Hiring of vehicle (4 wheeler)Rate as per G.O.MS.No.87Dated 01-06-2017. |
| 5298 | MAINTAINANCE OF LOCAL CONTROL STATION : |
| 5299 | Clear Water outlet-1 of Water Treatment plant |
| 5300 | Clear Water outlet-2 of Water Treatment plant |
| 5301 | Clear Water outlet-3 of Water Treatment plant |
| 5302 | Clear Water outlet-4 of Water Treatment plant |
| 5303 | Inlet of 200 KL Existing ELSR at Jarajapupeta panchayat office |
| 5304 | Inlet of 250 KL Existing ELSR at Gandhi nagar |
| 5305 | Inlet of 120 KL Existing ELSR at Saali veedhi |
| 5306 | Inlet of 200 KL Existing ELSR at Kondapeta |
| 5307 | Inlet of 130 KL Existing GLSR at Panchayat office |
| 5308 | Inlet of 400 KL Existing GLSR at Naidu colony |
| 5309 | Inlet of 300 KL Existing ELSR at Chandrababunaidu colony |
| 5310 | Inlet of 500 KL Existing ELSR at Jarajapupeta high school ground |
| 5311 | Replacement of necessary tranducers for PH analysers |
| 5312 | Clear Water outlet-1 of Water Treatment plant |
| 5313 | Clear Water outlet-2 of Water Treatment plant |
| 5314 | Clear Water outlet-3 of Water Treatment plant |
| 5315 | Clear Water outlet-4 of Water Treatment plant |
| 5316 | Replacement of necessary tranducers for Turbidity analysers |
| 5317 | Clear Water outlet-1 of Water Treatment plant |
| 5318 | Clear Water outlet-2 of Water Treatment plant |
| 5319 | Clear Water outlet-3 of Water Treatment plant |
| 5320 | Clear Water outlet-4 of Water Treatment plant |
| 5321 | BSNL Charges for static IP |
| 5322 | GPRS Connections |
| 5323 | WTP Quality Management |
| 5324 | Pumping Stations |
| 5325 | ELSR Management |
| 5326 | DMA Management |
| 5327 | Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
| 5328 | Operation & Maintenance cost Central SCADA for ULB |
| 5329 | Application Engineer (Graduate Engineer)Rate as per Labour Rates LAB-00130 ofCSSR 2025-26 |
| 5330 | System Engineer (Diploma Engineer)Rate as per Labour Rates |
| 5331 | Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-26 |
| 5332 | Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 |
| 5333 | BSNL Charges for static IP |
| 5334 | Data base management for WEB reporting |
| 5335 | Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
| 5336 | 6.Yelamanchili |
| 5337 | BILL No.6.1:CONSTRUCTION OF 4.0 MM DIA INFILTRATION WELL No.1IN THE RIVER BED OF VARAHA AT YETTI KUPPAKA ANICUT |
| 5338 | 6.1.1 Infiltration No. 01 upto 12.00 mts depth |
| 5339 | 6.1.1.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trench |
| 5340 | 6.1.1.2 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30 cerb wall |
| 5341 | 6.1.1.3 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30-300mmthickk |
| 5342 | 6.1.1.4 Sinking of wells 4.00 m internal dia in sandy and other loose soils under water either by manual labour divers or by dredgers weighing the top of staining to assist the sinking etc., including dewatering to the extent necessary mechanical equipment crew charges etc., complete for the infiltration wells for the following depths for finished item of work |
| 5343 | a) 0 to 2 mts below water level |
| 5344 | b) 2 mts to 4 mts below water level |
| 5345 | c) 4 mts to 6 mts below water level |
| 5346 | d) 6 mts to 8.00 mts below water level |
| 5347 | e) 8.00 mts to 10.00 mts below water level |
| 5348 | f) 10.00 mts to 11.00 mts below water level |
| 5349 | g) 11.00 mts to 12.00 mts below water level |
| 5350 | 6.1.1.5 Providing plugging of well with 40 mm HBG chips including cost and conveyance of all materials and labour charges etc., complete |
| 5351 | 6.1.1.6 Providing plugging of well with 12 to 20 mm HBG metal including cost and conveyance of all materials and labour charges etc., complete |
| 5352 | 6.1.1.7 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30e.-150 mm thick slab |
| 5353 | 6.1.1.8 Supply , delivery and fixing of Structural steel forwell kerb of infiltration wells including fabrication, all taxes and duties etc complete |
| 5354 | 6.1.1.9 Supply and fixing of man hole FRC frame and covers complete as directed by the departmental enginner in charge of the work |
| 5355 | 6.1.1.10 Supply and fixing of 32 mm dia PVC of 6kg/sqcm at 150 mm C/C including fixing in steining wall in Zigzag manner as directed by departmental offficers |
| 5356 | 6.1.1.11 Supply and fixing of steps with 25mm dia rod at 300mm c/c including fabrication and fixing in intifiltration wellupto bottom of well |
| 5357 | 6.1.1.12 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5358 | BILL NO.6.1.2 INFILTRATION WELL No.2upto 12.70 mts depth |
| 5359 | 6.1.2.1. Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trench . |
| 5360 | 6.1.2.2 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30 cerb wall |
| 5361 | 6.1.2.3 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30-300mmthick |
| 5362 | 6.1.2.4 Sinking of wells 4.00 m internal dia in sandy and other loose soils under water either by manual labour divers or by dredgers weighing the top of staining to assist the sinking etc., including dewatering to the extent necessary mechanical equipment crew charges etc., complete for the infiltration wells for the following depths for finished item of work |
| 5363 | a) 0 to 2 mts below water level |
| 5364 | b) 2 mts to 4 mts below water level |
| 5365 | c) 4 mts to 6 mts below water level |
| 5366 | d) 6 mts to 8.00 mts below water level |
| 5367 | e) 8.00 mts to 10.00 mts below water level |
| 5368 | f) 10.00 mts to 11.00 mts below water level |
| 5369 | g) 11.00 mts to 12.00 mts below water level |
| 5370 | h) 12.00 mts to 12.70 mts below water level |
| 5371 | 6.1.2.5 Providing plugging of well with 40 mm HBG chips including cost and conveyance of all materials and labour charges etc., complete |
| 5372 | 6.1.2.6 Providing plugging of well with 12 to 20 mm HBG metal including cost and conveyance of all materials and labour charges etc., complete |
| 5373 | 6.1.2.7 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30e.-150 mm thick slab |
| 5374 | 6.1.2.8 Supply , delivery and fixing of Structural steel forwell kerb of infiltration wells including fabrication, all taxes and duties etc complete |
| 5375 | 6.1.2.9 Supply and fixing of man hole FRC frame and covers |
| 5376 | 6.1.2.10 Supply and fixing of 32 mm dia PVC of 6kg/sqcm at 150 mm C/C including fixing in steining wall in Zigzag manner as directed by departmental offficers |
| 5377 | 6.1.2.11 Supply and fixing of steps with 25mm dia rod at 300mm c/c including fabrication and fixing in intifiltration wellupto bottom of well |
| 5378 | 6.1.2.12 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5379 | BILL NO.6.1.3INFILTRATION WELL No.3 upto 12.90 mts depth |
| 5380 | 6.1.3.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trench . |
| 5381 | 6.1.3.2 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30 cerb wall |
| 5382 | 6.1.3.3 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30-300mmthick |
| 5383 | 6.1.3.4 Sinking of wells 4.00 m internal dia in sandy and other loose soils under water either by manual labour divers or by dredgers weighing the top of staining to assist the sinking etc., including dewatering to the extent necessary mechanical equipment crew charges etc., complete for the infiltration wells for the following depths for finished item of work |
| 5384 | a) 0 to 2 mts below water level |
| 5385 | b) 2 mts to 4 mts below water level |
| 5386 | c) 4 mts to 6 mts below water level |
| 5387 | d) 6 mts to 8.00 mts below water level |
| 5388 | e) 8.00 mts to 10.00 mts below water level |
| 5389 | f) 10.00 mts to 11.00 mts below water level |
| 5390 | g) 11.00 mts to 12.00 mts below water level |
| 5391 | h) 12.00 mts to 12.90 mts below water level |
| 5392 | 6.1.3.5 Providing plugging of well with 40 mm HBG chips including cost and conveyance of all materials and labour charges etc., complete |
| 5393 | 6.1.3.6 Providing plugging of well with 12 to 20 mm HBG metal including cost and conveyance of all materials and labour charges etc., complete |
| 5394 | 6.1.3.7 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum M30e.-150 mm thick slab.- |
| 5395 | 6.1.3.8 Supply , delivery and fixing of Structural steel forwell kerb of infiltration wells including fabrication, all taxes and duties etc complete |
| 5396 | 6.1.3.9 Supply and fixing of man hole FRC frame and covers |
| 5397 | 6.1.3.10 Supply and fixing of 32 mm dia PVC of 6kg/sqcm at 150 mm C/C including fixing in steining wall in Zigzag manner as directed by departmental offficers |
| 5398 | 6.1.3.11 Supply and fixing of steps with 25mm dia rod at 300mm c/c including fabrication and fixing in intifiltration wellupto bottom of well |
| 5399 | 6.1.3.12Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5400 | CAP BILL 6.2PROVIDINGINFILTRATION GALLARY WITH 600 MM DIA RCC PERFORATED PIPES IN THE RIVER BED OF VARAHA AT YETI KUPPAKA |
| 5401 | 6.2.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trench . |
| 5402 | 6.2.2 Earth work excavation for infiltration gallery in all soils under water including all leads shoring strutting bailing out of water and removal of shoring after completion of pipeline work includeing all labour charges etc., complete |
| 5403 | a) 0 MTo 1.00 M Depth |
| 5404 | b) 1 MTo 2.00 M Depth |
| 5405 | c) 2.00 MTo 5.00 M Depth |
| 5406 | d) 5.00 MTo 6.00 M Depth |
| 5407 | e) 6.00 MTo 7.00 M Depth |
| 5408 | f) 7.00 MTo 8.00 M Depth |
| 5409 | g) 8.00 MTo 9.0 M Depth |
| 5410 | h) 9.00 MTo 9.40 M Depth |
| 5411 | 6.2.3 Manufacture supply delivery of 600 mm RCC perforated NP3 class pipes conforming to BIS-458/2003includingperforatationcharges, cost of rubber rings, transportation including cost and conveyance of all meterials and all taxes, duties and all labour charges for laying and jointing etc., complete |
| 5412 | 6.2.4 Lowering , Laying and Jointingthe RCC S/S pipes carefully into the trenches laying them true to alignment and gradient, jointing with rubber rings and testing including filling with water with a water lead upto 500 meters including cost of rubber rings as per BIS No. 783/1985and collars (600 mm dia) |
| 5413 | 6.2.5 Laying of 40 mm HBG metal as filter meterial as per approved section of infiltration gallery includeing all costs ans conveyance of meterials and labour charges etc.,complete as per SS |
| 5414 | 6.2.6 Laying of 12 to 20 mm HBG metal asn filter meterial as per approved section of infiltration gallery includeing all costs ans conveyance of meterials and labour charges etc.,complete as per SS |
| 5415 | 6.2.7 Laying 6 to 12 mm HBG metal asn filter meterial as per approved section of infiltration gallery includeing all costs ans conveyance of meterials and labour charges etc.,complete as per SS |
| 5416 | 6.2.8 Laying of coarse sand passing through 3.35mm sieve and retained on 1.70mm sieve as filter media as per approved section of infilration gallery includeing all costs and conveyance of meterials and labour charges etc., complete as per SS |
| 5417 | 6.2.9 Laying of fine sand passing through 1.7mm sieve and retained on 70 microns sieve as per filter media as per approved section of infiltration gallery includeing all costs and conveyance of meterials and labour charges etc., complete as per SS |
| 5418 | 6.2.10 Refilling the excavated sand in the gallery trench in layers as per SS and as directed by the Engineer in charge |
| 5419 | CAPBill No:6.3 Construction of 8.0m Diacollectionwell cumPump House near yetikoppaka |
| 5420 | 6.3.1 Earthwork excavation and depositing on the bank in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel and soft disintegrated rock, like shelves,stonematrix, removable by pickaxes and crow bars rock boulders upto 3.0Cum Size etc for pipeline trenches by manual means and dump and as per specification drawings and as directed by the departmental officer andprotecting the walls other structures etc.,so as not to disturbthe existing utility servicesduring laying of pipeline taking all precautionary measures in the restricted areas with an initial lead of 50 M and with all lifts and delifts for pipe line trenches for laying watermains including divertion of traffic all incidental and operational charges etc., complete. |
| 5421 | 6.3.2 Supply and fabrication of structural steel for girders, angles etc |
| 5422 | 6.3.3 Providing HYSD rods of 20 mm Dia |
| 5423 | 6.3.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum l |
| 5424 | a) For Well Curb |
| 5425 | b) ForSide Wall -500 mm Thick |
| 5426 | c) For Roof Slab (250 mm Thick) |
| 5427 | 6.3.5 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5428 | 6.3.6 Well sinking in sandy and other loose soils under water either by manual labour,divers or dredgers,weighting the top of steining to assist sinking etc.,including dewatering and other incidental charges such as hire charges for mechanical equipment etc., complete upto 8.0 m internal dia |
| 5429 | a) Upto 2.0 m below GL/m |
| 5430 | b) From 2 -4 m below GL/m |
| 5431 | c) From 4 -6 m below GL/m |
| 5432 | d) From 6 -8 m below GL/m |
| 5433 | e) From 8-10 m below GL/m |
| 5434 | f) From 10 -11 m below GL/m |
| 5435 | g) From 11 -12 m below GL/m |
| 5436 | h) From 12 -13.4 m below GL/m |
| 5437 | 6.3.7 Suply and delivery and fixing ofPVC Encapsulated steps for infiltration well excluding all taxes and duries etc including finishing of steps (As per PHSSR item no.33) |
| 5438 | Pump House |
| 5439 | 6.3.8 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum m30 |
| 5440 | a) Side Wall -230 mm thick |
| 5441 | b) Roof Slab(150 mm thick) |
| 5442 | 6.3.9 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5443 | 6.3.10 Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at sitelabour charges for finishing and curing etc., complete as per S.S |
| 5444 | 6.3.11 Impervious coat 20mm thick average over VRCC roof slabs with CM(1:3) proportion mixed with approved brand of water proofing compound at the rate of 1.0Kg per bag of cement and laid when slab is green with thread lining and finished smooth with a floating cement of neat cement as directed including cost and conveyance of all metarials and water to work site seignorage and all operational, incidental labour charges such as mixing mortar laying curing etc complete for finished item of work |
| 5445 | 6.3.12 Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. |
| 5446 | 6.3.13 Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (APDSS No:1201) |
| 5447 | 6.3.14 Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per special spn: 1108 BMT-F.29 of building SSR |
| 5448 | 6.3.15 Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6\" pitch complete for finished item of work. |
| 5449 | 6.3.16 Manufacuture ,supply , delivery and fixing of M.S gantry girderwith chain pully with 3T capacity of standard make including fabrication , all labour charges etc complete |
| 5450 | Providing electrification including fixures |
| 5451 | 6.3.17 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 5452 | 6.3.18 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges |
| 5453 | 6.3.19 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 5454 | 6.3.20 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 5455 | 6.3.21 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 5456 | 6.3.22 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 5457 | 6.3.23 supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 5458 | 6.3.24 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 5459 | 6.3.25 Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete. |
| 5460 | 6.3.26 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 5461 | 6.3.27 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 5462 | 6.3.28 Supply of 9\" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT |
| 5463 | 6.3.29 Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs. |
| 5464 | 6.3.30 Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 5465 | 6.3.31 Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete |
| 5466 | 6.3.32 Supply and fixing of Stain less steel ladder made out of suitable sections for access from floor slab to Base slab |
| 5467 | CAP BILL NO.6.4 Construction of RCC Walk way Bridge for Collection well cum pumphouse at Yetikupaka |
| 5468 | 6.4.1 Earth Work Excavation by Machinery in all marshy Soils up to SDR & Stone Matrix with in a radius of 5m ie., cut and Dump |
| 5469 | a) Up to 3mbelow GL |
| 5470 | b) 3.00 to 6.00 mtrs |
| 5471 | c) 6.00 to 10.00 mtrs |
| 5472 | 6.4.2 Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 5473 | 6.4.3 Providing Levelling Course Cement concrete ( 1: 4 : 8)using 40mm nominal size graded HBG metalincluding cost of all materialsand labour charges for laying,ramming and wateringetc. complete |
| 5474 | 6.4.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etc unit 1.00cum m30 |
| 5475 | a) Footings |
| 5476 | b) Tie Beam 1 |
| 5477 | c) Tie Beam 2 |
| 5478 | d) Beam 1 |
| 5479 | e) Column |
| 5480 | f) Walkway Slab -150 mm Thick |
| 5481 | 6.4.5 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5482 | 6.4.8 Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD including cost of necessary reinforcement etc.complete as per S.S |
| 5483 | CAP BILL NO.6.5 Supply, Delivery & Erection of Vertical Turbine Pumpsets in Intake well in Varaha River |
| 5484 | 6.5.1 Providing Clear Water Pumping system at Varaha Riverby supply, delivery and erection ofVT pump set with specifications ofHead range of 89 mtrs, discharge of 252 M3/Hr for clear Water(2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer |
| 5485 | 6.5.2 Supply, delivery and erection ofVFD Control Panels for Pump sets with the following specifications as belowand the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer. ( 1 X 3 UNIT ). 1 UNIT = 125 kw. Total= 375 KW. |
| 5486 | CAP BILL NO.6.6 PROVIDING 500 KVA TRANSFORMER WITH ALL ACCESSORIES AND DEDICATED FEEDER MAIN |
| 5487 | 6.6.1 Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply |
| 5488 | 6.6.2 Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113 |
| 5489 | 6.6.3 Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111 |
| 5490 | 6.6.4 Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110 |
| 5491 | 6.6.5 Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps |
| 5492 | 6.6.6 Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105 |
| 5493 | 6.6.7 Providing jumper connections with I/O\" SWG HDBC wire between the 11 KV equipment on the outdoor structures |
| 5494 | 6.6.8 Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097 |
| 5495 | 6.6.9 Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below: |
| 5496 | A) Earth Electrodes |
| 5497 | B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146 |
| 5498 | C) Epoxy insulators |
| 5499 | D) No.\"8\" SWG Copper wire. MAT 04141 |
| 5500 | 6.6.10 Supply and Transportation of ISI marked copper wound Transformers11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating.Makes : As per list of recommended brands as category I. MAT-04046e 500KVA |
| 5501 | 6.6.11 Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431 |
| 5502 | 6.6.12 A Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel,hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976 |
| 5503 | 6.6.12 b) Supply and fixing of Electrolytic grade copper bus barbus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978 |
| 5504 | 6.6.13a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 5505 | b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 5506 | c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980 |
| 5507 | d) Supply and fixing of selector switch for voltmeter (4position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03989 |
| 5508 | e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983 |
| 5509 | f).Supply and fixing of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required Make: L&T /C&S/SALZER/HPL MAT 03990 |
| 5510 | g).3RYB Phase indication lamps with leds |
| 5511 | h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986 |
| 5512 | 6.6.14 a)630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 5513 | b)630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 5514 | c)630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 5515 | d)630A TPN SDFU for SpaceMakes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 5516 | e)630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885 |
| 5517 | f)630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898 |
| 5518 | g) KWH digital meter fro lighting section |
| 5519 | h) Supply of32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3Makes: As per list of recommended brands as category I.MAT-02879 |
| 5520 | i)Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2Makes: As per list of recommended brands as category I MAT-02938 |
| 5521 | j)Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998 |
| 5522 | 6.6.15 1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete. |
| 5523 | 6.6.16 Supply and Laying of 3C X 95Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03460 |
| 5524 | 6.6.17 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTHNote : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By manual means |
| 5525 | 6.6.18Providing river Crusher Dustfilling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss |
| 5526 | 6.6.19 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 5527 | 6.6.20 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 2 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete, vibrating,curing etcM25 des0ign mix concrete |
| 5528 | a)column footings |
| 5529 | b)Columns1.20-0.10-0.10-0.30+1.80 |
| 5530 | c)Plinth beam2(15+12)=54-gate3.00=51.00 |
| 5531 | 6.6.21 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 5532 | 6.6.22Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5533 | 6.6.23 Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately). |
| 5534 | 6.6.24 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete |
| 5535 | 6.6.25 Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per ss |
| 5536 | 6.6.26 supply and filling the transformer yard with 40mm HBG metal m/c |
| 5537 | CAP BILL NO.6.7 Laying of DI K9clear water pumping mainfrom Collection well to Existing and ProposedGLSRs ELSRs |
| 5538 | 6.7.1 Cutting open bituminous tar road surface including depositingof excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25a (PH SSR). |
| 5539 | a) 300 mm dia DI K9 pipe |
| 5540 | b) 350 mm dia DI K9 pipe |
| 5541 | c) 450 mm dia DI K9 pipe |
| 5542 | 6.7.2 Cutting open cement concrete road surface including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25b (PH SSR). |
| 5543 | a) 300 mm dia DI K9 pipe |
| 5544 | b) 350 mm dia DI K9 pipe |
| 5545 | c) 450 mm dia DI K9 pipe |
| 5546 | 6.7.3 Cutting open water bound macadam road including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete - 1 cum SSR Sl.No.25c(PH SSR). |
| 5547 | a) 300 mm dia DI K9 pipe |
| 5548 | b) 350 mm dia DI K9 pipe |
| 5549 | c) 450 mm dia DI K9 pipe |
| 5550 | 6.7.4 RBR - FNDN-1 - (i-B) - In ordinary soils, by Mechanical means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material, dressing of sides and bottom as per Technical Specification 304 MORTH and as directed by the departmental officer including protecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earth upto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 5551 | 6.7.5 BLD-CSTN-2-5 - (13): Earth work excavation in Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth |
| 5552 | 6.7.6 RBR - FNDN - 1 - (i-A) In ordinary soils, by Manual means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 5553 | 6.7.7 RBR-FNDN-1- (iv) - In hard rockblasting prohibited: Excavation in Hard rock (blasting prohibited) Upto 3 m depth including 1.5 m depth in hard rock : Earthwork excavation in hard rock such as sheet rock and boulders in habitant areas where conventional blasting can not be donefor pipe line trenches, including all incidental and operational charges etc., complete. bends and specials |
| 5554 | 6.7.8.RBR-FNDN-1 - manual means : Earthwork excavation for structures in all types of soil as per drawing and technical specificationsincluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH. for Sumps,Thrust blocks, Chambers and Man Holes etc. by manual means. |
| 5555 | a) for specials of 300 mm dia |
| 5556 | b) for specials of 350 mm dia |
| 5557 | c) for specials of 450 mm dia |
| 5558 | 6.7.9PHE-BHLW-26; Barricading, hoarding, lighting and watching etc., for water supply and sewerage works for trenches of depths upto 6’-0” (2 Meter) below G.L |
| 5559 | 6.7.10 Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K9suitable for push on joint (Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation and ST etc,. complete. but excluding CED. |
| 5560 | a) 300 mm dia DI K9 pipe |
| 5561 | b) 350 mm dia DI K9 pipe |
| 5562 | c) 450 mm dia DI K9 pipe |
| 5563 | 6.7.11 PHE-LCIS-1: Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 5564 | a) 300 mm dia DI K9 pipe |
| 5565 | b) 350 mm dia DI K9 pipe |
| 5566 | c) 450 mm dia DI K9 pipe |
| 5567 | 6.7.12 PHE-JCIR-4: Jointing the, D.I. Pipes & fittings with Rubber Gasket, including the cost of the gasket, all sundries filling with water with a water lead upto 500 m and testing to required pressure etc., complete as per BIS No.3114/85. |
| 5568 | a) 300 mm dia DI K9 pipe |
| 5569 | b) 350 mm dia DI K9 pipe |
| 5570 | c) 450 mm dia DI K9 pipe |
| 5571 | 6.7.13 Manufacture, supply and delivery of centrifugally cast (spun ) ductile iron fittings conforming to IS No. 9523/2000 having dimentions as per table. , zinc coated externally with inside mortor lining (with finishing as per class 13/IS 9523/2000 as per Code No 1 ) including transportation, taxes and duties etc. Up to 500mm dia |
| 5572 | 6.7.13.1 Tees |
| 5573 | a) 200*200*80mmAir Tee |
| 5574 | b) 200 x 200x150mm scour Tee |
| 5575 | c) 300*300*80mm Air Tee |
| 5576 | d) 300*300*150mm Scour Tee |
| 5577 | e) 350*350*100mm Air Tee |
| 5578 | f) 350*350*150mm Scour Tee |
| 5579 | g) 450*450*100mm Air Tee |
| 5580 | h) 450*450*150mm Scour Tee |
| 5581 | 6.7.13.2 Flanged Sockets /Spigot |
| 5582 | a) 200 mm dia |
| 5583 | b) 250 mm dia |
| 5584 | 6.7.13.3Flanged Socket reducer |
| 5585 | a) 450/300mm taper |
| 5586 | 6.7.13.4 Double socketbends |
| 5587 | a) 300 mm dia |
| 5588 | b) 350 mm dia |
| 5589 | c) 450 mm dia |
| 5590 | as persite condition |
| 5591 | 6.7.14 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 5592 | 6.7.14.1 DI. D/F Sluice valves ofPN.16 class |
| 5593 | a) 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 5594 | 6.7.14.2 Sluice valves for scour |
| 5595 | a) 150mm dia Sluice Valves |
| 5596 | 6.7.14.3 IsolatedSluice valves for air valves |
| 5597 | a) 80mm dia Sluice Valves |
| 5598 | b) 100mm dia Sluice Valves |
| 5599 | 6.7.15 Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) of following dia. conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steel; including transportation and excluding all taxes complete. |
| 5600 | a) 300mm Dia |
| 5601 | 6.7.16 Manufacture, Supply and Delivery of CI/DI Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 5602 | a) 300mm Dia |
| 5603 | 6.7.17 Manufacture, Supply and Delivery of MS Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 5604 | a) 450mm Dia |
| 5605 | 6.7.18 PHE-CISV-15 : Lowering, keeping in position and fixing D.I. sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 5606 | a) 80mm dia Sluice Valves |
| 5607 | b) 100mm dia Sluice Valves |
| 5608 | c) 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 5609 | 6.7.19 PHE-JCIF-5-: Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 5610 | a) 80mm dia Sluice Valves |
| 5611 | b) 100mm dia Sluice Valves |
| 5612 | c) 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 5613 | 6.7.20 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. |
| 5614 | a) 80mm dia Air Valves |
| 5615 | b) 100mm dia Air Valves |
| 5616 | 6.7.21 Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 5617 | a) 80mm dia Air Valves |
| 5618 | b) 100mm dia Air Valves |
| 5619 | 6.7.22 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 5620 | a) for 250mmdia to 350 Sluice valves |
| 5621 | 6.7.23 Carting away thesurplus excavatedmaterial i.e.Earthand Rubble from the site to a suitabledistanceof about 5.00 Kmincluding loading, unloading , conveyance charges and dumping the carted material at the contractors cost, labour charges, all leads & lifts and other incidental and operational charges etc., complete. |
| 5622 | 6.7.24 Railway crossing/Road crossing/Canal crossing by adopting trenchless technology tunneling work through specialized pipe jacking method by erecting the equipment to true to the alignment and gradient, by hydraulic pipe jacking technique complete including tunneling, excavation in all types of soils including hard rock and construction of RCC chambers suitable to casing pipe pits, and conveyance charges of machinery and other required materials but including cost of encasing pipe, in co-ordination with the concerned authorities as per approved drawings and directed by the Engineer-in – Charge. |
| 5623 | a) Highway crossing with 800 mm dia 12mm Thick encasing pipe 1.761+100 ( 200 mm Dia DI-K-7- G’Main from Seshukonda to Yerravaram ELSR ) 2.761+200 ( 350 mm Dia DI-K-9-Pumping Main to VB Konda ) |
| 5624 | b) Railway crossing with 800 mm dia 12mm Thick encasing pipe Crossing of Water Supply pipe line between EP No’s : 718/19 and 718/22( 350 mm Dia DI-K-9-Pumping Main to VB Konda ) |
| 5625 | 6.7.25 Manufacture, supply and delivery of M.S Spirally Welded Pipes conforming to IS: 3589/2001 including in lining with cement mortar (1:2) 15mm thick using 4 numbers of 6mm dia. M.S. Rings at each end of the pipe and out coating with cement mortar (1:3) 30mm thick by short crating (or) guniting duly providing wire mesh of size 50x50x3mm including cost of all materials, labor charges, transportation to anywhere in AP, but excluding all taxes. |
| 5626 | a)800 mm dia 12mm thick |
| 5627 | b) 800 mm dia 12mm thick |
| 5628 | 6.7.26 Manufacture, supply and delivery of Ductile Ironpipes and fittings (spls.) conforming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988 at site of work anywhere in A.P.including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. |
| 5629 | 6.7.26.1 for Scouring arrangments - 100mm dia |
| 5630 | a) duck foot bends |
| 5631 | b) Semi circular bends |
| 5632 | c) CI D/F pipes -0.60m |
| 5633 | 6.7.26.2 for Scouring arrangments - 150mm dia |
| 5634 | a) duck foot bends |
| 5635 | b) Semi circular bends |
| 5636 | c) CI D/F pipes -0.60m |
| 5637 | 6.7.26.3 for Scouring arrangments - 200mm dia |
| 5638 | a) duck foot bends |
| 5639 | b) Semi circular bends |
| 5640 | c) CI D/F pipes -0.60m |
| 5641 | d) add for short Pipes & Bends, Specials,.Scouring arrangements& inter connections etc as per site condition |
| 5642 | 6.7.27 Providing Anchor Blocks / Thrust blocks where ever necessary with RCC M20 grade concrete |
| 5643 | 6.7.28 Fabrication, supply, erection and commissioning of 1 metre wide walkway connecting spillway piers / abutments at trunnion platform level including cost of all materials,machinery, labour, cutting, welding etc, complete as per specifications and approved drawings(without painting on sand-blasted or mechanical cleaning surfaces which are added extra as perscedule of rates under itemsinthis chapter and add as applicable separately) |
| 5644 | 6.7.29 Construction ofBridge for supporting 450 mm dia DI.K9 pipe acrossPolavaram Left Main Canal at Chainage -149.45 mtrs |
| 5645 | CAP BILL NO.6.8 Laying of DI K7 Clear water Gravitymains from Tapping pointto Existing and Proposed ELSRs |
| 5646 | 6.8.1 Cutting open bituminous tar road surface including depositingof excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25a (PH SSR). |
| 5647 | a) 150mm dia DI K7 pipe |
| 5648 | b) 200mm dia DI K7 pipe |
| 5649 | c) 250mm dia DI K7 pipe |
| 5650 | d) 300mm dia DI K7 pipe |
| 5651 | 6.8.2 Cutting open cement concrete road surface including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete. SSR Sl.No.25b (PH SSR). |
| 5652 | a) 150mm dia DI K7 pipe |
| 5653 | b) 200mm dia DI K7 pipe |
| 5654 | c) 250mm dia DI K7 pipe |
| 5655 | d) 300mm dia DI K7 pipe |
| 5656 | 6.8.3 Cutting open water bound macadam road including depositing of excavated materials for trench work including labour charges and all incidental and operational charges etc., complete - 1 cum SSR Sl.No.25c(PH SSR). |
| 5657 | a) 150mm dia DI K7 pipe |
| 5658 | b) 200mm dia DI K7 pipe |
| 5659 | c) 250mm dia DI K7 pipe |
| 5660 | d) 300mm dia DI K7 pipe |
| 5661 | 6.8.4 RBR - FNDN-1 - (i-B) - In ordinary soils, by Mechanical means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material, dressing of sides and bottom as per Technical Specification 304 MORTH and as directed by the departmental officer including protecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earth upto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 5662 | % of the EWE Quantity |
| 5663 | 6.8.5 BLD-CSTN-2-5 - (13): Earth work excavation in Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Mechanical Means-Upto 3 m depth |
| 5664 | % of the EWE Quantity |
| 5665 | 6.8.6 RBR - FNDN - 1 - (i-A) In ordinary soils, by Manual means: Earthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 5666 | % of the EWE Quantity |
| 5667 | 6.8.7 RBR-FNDN-1- (iv) - In hard rockblasting prohibited: Excavation in Hard rock (blasting prohibited) Upto 3 m depth including 1.5 m depth in hard rock : Earthwork excavation in hard rock such as sheet rock and boulders in habitant areas where conventional blasting can not be donefor pipe line trenches, including all incidental and operational charges etc., complete. |
| 5668 | % of the EWE Quantity |
| 5669 | 6.8.8 RBR-FNDN-1 - manual means : Earthwork excavation for structures in all types of soil as per drawing and technical specificationsincluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH. for Sumps,Thrust blocks, Chambers and Man Holes etc. by manual means. |
| 5670 | bends and specials |
| 5671 | for specials of300mm dia |
| 5672 | 6.8.9 PHE-BHLW-26; Barricading, hoarding, lighting and watching etc., for water supply and sewerage works for trenches of depths upto 6’-0” (2 Meter) below G.L |
| 5673 | for main roads in habitation area |
| 5674 | 6.8.10 Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K7suitable for push on joint (Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportation and ST etc,. complete. but excluding CED. |
| 5675 | a) 200 mm dia DI K7 Pipe |
| 5676 | b) 250 mm dia DI K7 Pipe |
| 5677 | c) 300 mm dia DI K7 Pipe |
| 5678 | 6.8.11 PHE-LCIS-1: Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 5679 | a) 150 mm dia DI K7 Pipe |
| 5680 | b) 200 mm dia DI K7 Pipe |
| 5681 | c) 250 mm dia DI K7 Pipe |
| 5682 | d) 300 mm dia DI K7 Pipe |
| 5683 | 6.8.12 PHE-JCIR-4: Jointing the, D.I. Pipes & fittings with Rubber Gasket, including the cost of the gasket, all sundries filling with water with a water lead upto 500 m and testing to required pressure etc., complete as per BIS No.3114/85. |
| 5684 | a) 150 mm dia DI K7 Pipe |
| 5685 | b) 200 mm dia DI K7 Pipe |
| 5686 | c) 250 mm dia DI K7 Pipe |
| 5687 | d) 300 mm dia DI K7 Pipe |
| 5688 | 6.8.13 Manufacture, supply and delivery of centrifugally cast (spun ) ductile iron fittings conforming to IS No. 9523/2000 having dimentions as per table. , zinc coated externally with inside mortor lining (with finishing as per class 13/IS 9523/2000 as per Code No 1 ) including transportation, taxes and duties etc. |
| 5689 | Up to 500mm dia |
| 5690 | 6.8.13.1 Tees |
| 5691 | 200*200*80mmAir Tee |
| 5692 | 200 x 200 x 150mm scour Tee |
| 5693 | 300*300*80mm Air Tee |
| 5694 | 300*300*150mm Scour Tee |
| 5695 | 350*350*100mm Air Tee |
| 5696 | 350*350*150mm Scour Tee |
| 5697 | 6.8.13.2 Flanged Sockets /Spigot |
| 5698 | 200mm |
| 5699 | 250mm |
| 5700 | 300mm |
| 5701 | 6.8.13.3 Double socketbends |
| 5702 | 250mm |
| 5703 | 300mm |
| 5704 | Add extra as per site condition |
| 5705 | 6.8.14 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 5706 | 6.8.14.1 DI. D/F Sluice valves ofPN.16 class |
| 5707 | 100mm dia Sluice Valves |
| 5708 | 150mm dia Sluice Valves |
| 5709 | 200mm dia Sluice Valves |
| 5710 | 250mm dia Sluice Valves |
| 5711 | 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 5712 | Sluice valves for scour |
| 5713 | 150mm dia Sluice Valves |
| 5714 | 6.8.14.2 Isolated Sluice valves for air valves |
| 5715 | 80mm dia Sluice Valves |
| 5716 | 100mm dia Sluice Valves |
| 5717 | 6.8.15 Manufacture, Supply and Delivery of DI Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 5718 | 100mm Dia |
| 5719 | 150mm Dia |
| 5720 | 200mm Dia |
| 5721 | 250mm Dia |
| 5722 | 300mm dia |
| 5723 | 6.8.16 PHE-CISV-15 : Lowering, keeping in position and fixing D.I. sluice valves (with cap / with hand wheel & reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 5724 | 80mm dia Sluice Valves |
| 5725 | 100mm dia Sluice Valves |
| 5726 | 150mm dia Sluice Valves |
| 5727 | 200mm dia Sluice Valves |
| 5728 | 250mm dia Sluice Valves |
| 5729 | 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 5730 | 6.8.17 PHE-JCIF-5-: Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 5731 | 80mm dia Sluice Valves |
| 5732 | 100mm dia Sluice Valves |
| 5733 | 150mm dia Sluice Valves |
| 5734 | 200mm dia Sluice Valves |
| 5735 | 250mm dia Sluice Valves |
| 5736 | 300mm dia Sluice Valves for 300mm to 450mm dia pipes |
| 5737 | 6.8.18 Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation. |
| 5738 | 80mm |
| 5739 | 100mm |
| 5740 | 6.8.19 Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 5741 | 80mm |
| 5742 | 100mm |
| 5743 | 6.8.20 Supply and fixing of precast RCC chambers having the size of 910mm at bottom and 530mm at top with tapers along with FRC cover and frame, laying in CC (1:2:4) prop including cost of material, labour charges, curing, conveyance etc., complete as per standard specifications and standard drawings.. |
| 5744 | For up to 200mm dia Sluicevalves and forrevamping pipe lines |
| 5745 | 6.8.21 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 5746 | for 250mmdia to 350 Sluice valves |
| 5747 | 6.8.22 Carting away thesurplus excavatedmaterial i.e.Earthand Rubble from the site to a suitabledistanceof about 5.00 Kmincluding loading, unloading , conveyance charges and dumping the carted material at the contractors cost, labour charges, all leads & lifts and other incidental and operational charges etc., complete. |
| 5748 | 90% of rock Qty |
| 5749 | 6.8.23 Manufacture, supply and delivery of Ductile Ironpipes and fittings (spls.) conforming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988 at site of work anywhere in TG.including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. |
| 5750 | 6.8.23.1 for Scouring arrangments - 100mm dia |
| 5751 | duck foot bends |
| 5752 | Semi circular bends |
| 5753 | CI D/F pipes -0.60m |
| 5754 | 6.8.23.2 for Scouring arrangments - 150mm dia |
| 5755 | duck foot bends |
| 5756 | Semi circular bends |
| 5757 | CI D/F pipes -0.60m |
| 5758 | add for short Pipes & Bends, Specials,.Scouring arrangements& inter connections etc as per site condition |
| 5759 | CAP.BILL NO.6.9. Construction of 1100 KL capacity Ground Level Service Reservoir (GLSR) cum Balancing Reservoir on Veerabadrakonda. |
| 5760 | 6.9.1 RBR-FNDN-1-A: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for Sumps, |
| 5761 | in all types of soils |
| 5762 | 6.9.2 RBR-EECD-9 -ii-B : Excavation in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 MORD / 301 MORTH ( for all lifts by machanical means) |
| 5763 | in all types of soils |
| 5764 | 6.9.3 BLD-CSTN-2-5 (22) -Using Concrete mixture all works up to Plinth Level : Plain Cement concrete nominal mix (1:3:6) prop (Cement : fine aggregate: coarse aggregate ) using 40mm size Hard Granite Machine Crushed Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work.for foundation andunder flooring bed. |
| 5765 | levelling course below Base slab ( ∏ x r2 x h ) |
| 5766 | 6.9.4 BLD-CSTN-2-14: Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code . for FOUNDATIONS, PLINTH, PEDESTALS (Below Plinth) |
| 5767 | Base slab ( ∏ x r2 x h ), Heal & Haunch |
| 5768 | Column footings |
| 5769 | Pedestals |
| 5770 | 6.9.5 BLD-CSTN-2-15: Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code for COLUMNS, LINTELS, WATER TANKS, RCC WALLS IN BUILDINGS |
| 5771 | Side Wall 380 mm thick (Avg) (2 ∏ x r x t x h ) |
| 5772 | Columns |
| 5773 | 6.9.6 BLD-CSTN-3-14-(31)-C : Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,completefor finished item of work(APSS No. 402) with minimum cement content as per IS codeincluding pumping, centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. for RCC SLABS, BEAMS |
| 5774 | Top Dome(∏ x ( r2 + h2 ) |
| 5775 | Roof slab = 2 x Pi x r x width of slab x t |
| 5776 | Outer & inner Ring Beam 0.45 x 0.60 -(2 ∏ x r x t x h ) |
| 5777 | 6.9.7 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5778 | Top Dome |
| 5779 | Roof slab |
| 5780 | Ring beams |
| 5781 | Side Wall |
| 5782 | Footings |
| 5783 | Pedastals |
| 5784 | Columns |
| 5785 | Wall footing |
| 5786 | Base Slab including Haunch |
| 5787 | 6.9.8 Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. |
| 5788 | Outer walls above Ground level - (2 ∏ x r x h ) |
| 5789 | Outer side of the ring beam - (2 ∏ x r x h ) |
| 5790 | Surface area of Top dome |
| 5791 | 6.9.9 Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for internal walls |
| 5792 | Outer walls above Ground level - (2 ∏ x r x h ) |
| 5793 | Outer side of the ring beam - (2 ∏ x r x h ) |
| 5794 | Surface area of Top dome |
| 5795 | 6.9.10 Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes.H.D. -20 with 560 mm dia. Clear opening |
| 5796 | 1 x 2 x 180 Kgs each |
| 5797 | 6.9.11 Supply and delivery and fixing in position M S gril of any design including all fabrication and all fixing charges etc compalete as per ss and as directed by the dept authorities MS Ladder work. |
| 5798 | Supply and delivery and fixing in position M S gril |
| 5799 | 6.9.12 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 5800 | 200 mm dia Sluice Valve foroutlet PN-1.6 |
| 5801 | 300mm dia valve PN-1.6 |
| 5802 | 6.9.13 PHE-CISV-15- Lowering, keeping in position and fixing C.I. sluice valves (with cap / with hand wheel & Reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces. |
| 5803 | 300mm dia valve PN-1.6 |
| 5804 | 200 mm dia Sluice Valve foroutlet PN-1.6 |
| 5805 | 6.9.14 PHE-JCIF-5- Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 5806 | 300mm dia valve PN-1.6 |
| 5807 | 200 mm dia Sluice Valve foroutlet PN-1.6 |
| 5808 | 6.9.15 Manufacture, supply and delivery of DI pipes and fittings (spls.)confirming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988at site of work anywhere in AP. including, loading,unloading, transportation to site of work stacking at site transit risk and package, including taxes and duties etc, complete. |
| 5809 | 6.9.15.1OVER FLOW |
| 5810 | 300mm Duck foot bend |
| 5811 | 300mm Ø puddle pipe 1.25mts long |
| 5812 | 300mm Ø 900 bends |
| 5813 | 300mm Ø D/F 2 mts long pipe |
| 5814 | 6.9.15.2 INLET |
| 5815 | 400mm Duck foot bend |
| 5816 | 400mm Ø puddle pipe 1.25mts long |
| 5817 | 400 mm dia of bell mouth |
| 5818 | 400mm Ø D/F 2 mts long pipe |
| 5819 | 400mm Ø 900 bends |
| 5820 | 6.9.15.3 OUTLET |
| 5821 | 250mm Duck foot bend |
| 5822 | 250mm Ø puddle pipe 1.25mts long |
| 5823 | 250 mm dia of bell mouth |
| 5824 | 250mm Ø D/F 2 mts long pipe |
| 5825 | 250mm Ø 900 bends |
| 5826 | Cost of valve chambers for 300mm Valve as per separate estimate |
| 5827 | Cost of valve chambers for 400mm Valve as per separate estimate |
| 5828 | Add Head Load at 1% |
| 5829 | 6.10.Construction of 300 KL capacity Ground Level Service Reservoir (GLSR) cum Balancing Reservoir on Sheshukonda. |
| 5830 | 6.10.1 RBR-FNDN-1-A: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for Sumps, |
| 5831 | in all types of soils |
| 5832 | 6.10.2 RBR-EECD-9 -ii-B : Excavation in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 MORD / 301 MORTH ( for all lifts by machanical means) |
| 5833 | in all types of soils |
| 5834 | 6.10.3 BLD-CSTN-3-5 (22) -Using Concrete mixture all works up to Plinth Level : Plain Cement concrete nominal mix (1:3:6) prop (Cement : fine aggregate: coarse aggregate ) using 40mm size Hard Granite Machine Crushed Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work.for foundation andunder flooring bed. |
| 5835 | levelling course below Base slab ( ∏ x r2 x h ) |
| 5836 | 6.10.4 BLD-CSTN-2-14: Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code . for FOUNDATIONS, PLINTH, PEDESTALS (Below Plinth) |
| 5837 | Base slab ( ∏ x r2 x h ), Heal & Haunch |
| 5838 | Column footings |
| 5839 | Pedastals |
| 5840 | 6.10.5 BLD-CSTN-2-15: Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code for COLUMNS, LINTELS, WATER TANKS, RCC WALLS IN BUILDINGS |
| 5841 | Side Wall 380 mm thick (Avg) (2 ∏ x r x t x h ) |
| 5842 | Columns |
| 5843 | 6.10.6 BLD-CSTN-3-14-(31)-C : Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,completefor finished item of work(APSS No. 402) with minimum cement content as per IS codeincluding pumping, centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. for RCC SLABS, BEAMS |
| 5844 | Top Dome(∏ x ( r2 + h2 ) |
| 5845 | Roof slab = 2 x Pi x r x width of slab x t |
| 5846 | Net Qty |
| 5847 | Outer & inner Ring Beam 0.45 x 0.60 -(2 ∏ x r x t x h ) |
| 5848 | 6.10.7 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5849 | Top Dome |
| 5850 | Roof slab |
| 5851 | Ring beams |
| 5852 | Side Wall |
| 5853 | Footings |
| 5854 | Pedastals |
| 5855 | Columns |
| 5856 | Wall footing |
| 5857 | Base Slab including Haunch |
| 5858 | 6.10.8 Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. |
| 5859 | Outer walls above Ground level - (2 ∏ x r x h ) |
| 5860 | Outer side of the ring beam - (2 ∏ x r x h ) |
| 5861 | Surface area of Top dome |
| 5862 | 6.10.9 Painting to new walls with 2 coats of Food Neutral Epoxy coating of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for internal walls |
| 5863 | Outer walls above Ground level - (2 ∏ x r x h ) |
| 5864 | Outer side of the ring beam - (2 ∏ x r x h ) |
| 5865 | Surface area of Top dome |
| 5866 | 6.10.10 Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including,loading, un-loading & stacking at site but excluding all taxes. H.D.-20 with 560mm dia. Clear opening |
| 5867 | 6.10.11 Supply and delivery and fixing in position M S gril of any design including all fabrication and all fixing charges etc compalete as per ss and as directed by the dept authorities MS Ladder work. |
| 5868 | 6.10.12 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.. |
| 5869 | 200 mm dia sluice valve for outlet |
| 5870 | 200mm dia valve |
| 5871 | 6.10.13 PHE-CISV-15- Lowering, keeping in position and fixing C.I. sluice valves (with cap / with hand wheel & Reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces. |
| 5872 | 200mm dia valve |
| 5873 | 200 mm dia sluice valve for outlet |
| 5874 | 6.10.14 PHE-JCIF-5- Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 5875 | 200mm dia valve |
| 5876 | 200 mm dia sluice valve for outlet |
| 5877 | 6.10.15 Carting of surplus excavated Earth/ rock from the site upto 5kmsdistanceincluding loading, unloading charges, cost & conveyance, dumping, labour charges, all leads & lifts and other incidental and operational charges etc., complete. |
| 5878 | Total EWE Qty |
| 5879 | 6.10.16 Manufacture, supply and delivery of DI pipes and fittings (spls.)confirming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988at site of work anywhere in AP. including, loading,unloading, transportation to site of work stacking at site transit risk and package, including taxes and duties etc, complete. |
| 5880 | 6.10.16.1 OVER FLOW |
| 5881 | 300mm Duck foot bend |
| 5882 | 300mm Ø puddle pipe 1.25mts long |
| 5883 | 300mm Ø 900 bends |
| 5884 | 300mm Ø D/F 2 mts long pipe |
| 5885 | 6.10.16.2 INLET |
| 5886 | 400mm Duck foot bend |
| 5887 | 400mm Ø puddle pipe 1.25mts long |
| 5888 | 400 mm dia of bell mouth |
| 5889 | 400mm Ø D/F 2 mts long pipe |
| 5890 | 400mm Ø 900 bends |
| 5891 | 6.10.16.3 OUTLET |
| 5892 | 250mm Duck foot bend |
| 5893 | 250mm Ø puddle pipe 1.25mts long |
| 5894 | 250 mm dia of bell mouth |
| 5895 | 250mm Ø D/F 2 mts long pipe |
| 5896 | 250mm Ø 900 bends |
| 5897 | Cost of valve chambers for 300mm Valve as per separate estimate |
| 5898 | Cost of valve chambers for 400mm Valve as per separate estimate |
| 5899 | Add Head Load at 1% |
| 5900 | CAP BILL NO.6.11. Construction of 200 KL capacity Ground Level Service Reservoir (GLSR) on Gollolakonda. |
| 5901 | 6.11.1 RBR-FNDN-1-A: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for Sumps, |
| 5902 | in all types of soils |
| 5903 | 6.11.2 RBR-EECD-9 -ii-B : Excavation in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 MORD / 301 MORTH ( for all lifts by machanical means) |
| 5904 | in all types of soils |
| 5905 | 6.11.3 BLD-CSTN-3-5 (22) -Using Concrete mixture all works up to Plinth Level : Plain Cement concrete nominal mix (1:3:6) prop (Cement : fine aggregate: coarse aggregate ) using 40mm size Hard Granite Machine Crushed Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work.for foundation andunder flooring bed. |
| 5906 | levelling course below Base slab ( ∏ x r2 x h ) |
| 5907 | 6.11.4 BLD-CSTN-2-14: Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code . for FOUNDATIONS, PLINTH, PEDESTALS (Below Plinth) |
| 5908 | Base slab ( ∏ x r2 x h ),Heal & Haunch |
| 5909 | Column footings |
| 5910 | Pedastals |
| 5911 | 6.11.5 BLD-CSTN-2-15: Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code for COLUMNS, LINTELS, WATER TANKS, RCC WALLS IN BUILDINGS |
| 5912 | Side Wall 380 mm thick (Avg) (2 ∏ x r x t x h ) |
| 5913 | Columns |
| 5914 | 6.11.6 BLD-CSTN-3-14-(31)-C : Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,completefor finished item of work(APSS No. 402) with minimum cement content as per IS codeincluding pumping, centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. for RCC SLABS, BEAMS |
| 5915 | Top Dome(∏ x ( r2 + h2 ) |
| 5916 | Roof slab = 2 x Pi x r x width of slab x t |
| 5917 | Outer & inner Ring Beam 0.45 x 0.60 -(2 ∏ x r x t x h ) |
| 5918 | 6.11.7 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) |
| 5919 | Top Dome |
| 5920 | Roof slab |
| 5921 | Ring beams |
| 5922 | Side Wall |
| 5923 | Footings |
| 5924 | Pedastals |
| 5925 | Columns |
| 5926 | Wall footing |
| 5927 | Base Slab including Haunch |
| 5928 | 6.11.8 Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement.The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities. |
| 5929 | Outer walls above Ground level - (2 ∏ x r x h ) |
| 5930 | Outer side of the ring beam - (2 ∏ x r x h ) |
| 5931 | Surface area of Top dome |
| 5932 | 6.11.9 Painting to new walls with 2 coats of water proof cement paint of apporved brand and shade over a base coat of approved cement primer grade I making making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 912 for externalwalls |
| 5933 | Outer walls above Ground level - (2 ∏ x r x h ) |
| 5934 | Outer side of the ring beam - (2 ∏ x r x h ) |
| 5935 | Surface area of Top dome |
| 5936 | 6.11.10 Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers and frames with ISI marking anywhere in A.P., F.O.R. destination including,loading, un-loading & stacking at site but excluding all taxes. H.D.-20 with 560mm dia. Clear opening |
| 5937 | 6.11.11 Supply and delivery and fixing in position M S gril of any design including all fabrication and all fixing charges etc compalete as per ss and as directed by the dept authorities MS Ladder |
| 5938 | 6.11.12 Supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 5939 | 200 mm dia Sluice Valve foroutlet |
| 5940 | 200mm dia valve |
| 5941 | 6.11.13 PHE-CISV-15- Lowering, keeping in position and fixing C.I. sluice valves (with cap / with hand wheel & Reflex valves) excluding cost of bolts, nuts, rubber insertion, sluice valve and tail pieces. |
| 5942 | 200mm dia valve |
| 5943 | 200 mm dia Sluice Valve foroutlet |
| 5944 | 6.11.14 PHE-JCIF-5- Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 5945 | 200mm dia valve |
| 5946 | 200 mm dia Sluice Valve foroutlet |
| 5947 | 6.11.15 Carting of surplus excavated Earth/ rock from the site upto 5kmsdistanceincluding loading, unloading charges, cost & conveyance, dumping, labour charges, all leads & lifts and other incidental and operational charges etc., complete. |
| 5948 | Total EWE Qty |
| 5949 | 6.11.16 Manufacture, supply and delivery of DI pipes and fittings (spls.)confirming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988at site of work anywhere in AP. including, loading,unloading, transportation to site of work stacking at site transit risk and package, including taxes and duties etc, complete. |
| 5950 | 6.11.16.1 OVER FLOW |
| 5951 | 300mm Duck foot bend |
| 5952 | 300mm Ø puddle pipe 1.25mts long |
| 5953 | 300mm Ø 900 bends |
| 5954 | 300mm Ø D/F 2 mts long pipe |
| 5955 | 6.11.16.2 INLET |
| 5956 | 400mm Duck foot bend |
| 5957 | 400mm Ø puddle pipe 1.25mts long |
| 5958 | 400 mm dia of bell mouth |
| 5959 | 400mm Ø D/F 2 mts long pipe |
| 5960 | 400mm Ø 900 bends |
| 5961 | 6.11.16.3 OUTLET |
| 5962 | 250mm Duck foot bend |
| 5963 | 250mm Ø puddle pipe 1.25mts long |
| 5964 | 250 mm dia of bell mouth |
| 5965 | 250mm Ø D/F 2 mts long pipe |
| 5966 | 250mm Ø 900 bends |
| 5967 | 6.11.17 Cost of valve chambers for 300mm Valve as per separate estimate |
| 5968 | 6.11.18 Cost of valve chambers for 400mm Valve as per separate estimate |
| 5969 | Add Head Load at 1% |
| 5970 | CAP BILL N0. 6.12. Construction of 250 KL Capacity ELSR at YERRAVARAM in Zone-10. |
| 5971 | 6.12.1 Construction of 250 KL capacity Balancing Reservoir with a staging of 15 m with VRCC M30 mix including fixtures mentioned below |
| 5972 | 6.12.2 Necessary out let and inlet connection pipes shall provided. |
| 5973 | CAP BILL N0. 6.13. Construction of 500 KL Capacity ELSR at PEDAGOLLAPALEM in Zone-12. |
| 5974 | Construction of 500 KL capacity Balancing Reservoir with a staging of 15 m with VRCC M30 mix including fixtures mentioned below |
| 5975 | CAP BILL N0. 6.14. Construction of 200 KL Capacity ELSR at KOTTAPALEM in Zone-III. |
| 5976 | 6.14.1 Construction of 200 KL capacity Balancing Reservoir with a staging of 15 m with VRCC M30 mix including fixtures mentioned below |
| 5977 | 6.14.2 Necessary out let and inlet connection pipes shall provided. |
| 5978 | CAP BILL N0. 6.15. Construction of 200 KL Capacity ELSR at Ramarayudupalem in Zone-IV. |
| 5979 | 6.15.1 Construction of 200 KL capacity Balancing Reservoir with a staging of 15 m with VRCC M30 mix including fixtures mentioned below |
| 5980 | 6.15.2 Necessary out let and inlet connection pipes shall provided. |
| 5981 | CAP BILL N0. 6.16. Construction of 200 KL Capacity ELSR at Kokkiraapalli in Zone-13. |
| 5982 | 6.16.1 Construction of 200 KL capacity Balancing Reservoir with a staging of 15 m with VRCC M30 mix including fixtures mentioned below |
| 5983 | 6.16.2 Necessary out let and inlet connection pipes shall provided. |
| 5984 | CAP BILL N0. 6.17. Construction of 200 KL Capacity ELSR at THIRUVUPALLI in Zone-1. |
| 5985 | 6.17.1 Construction of 200 KL capacity Balancing Reservoir with a staging of 15 m with VRCC M30 mix including fixtures mentioned below |
| 5986 | 6.17.2 Necessary out let and inlet connection pipes shall provided. |
| 5987 | CAP BILL N0. 6.18. Construction of 300 KL Capacity ELSR at SOMALINGAPAALEM in Zone-2. |
| 5988 | 6.18.1 Construction of 300 KL capacity Balancing Reservoir with a staging of 15 m with VRCC M30 mix including fixtures mentioned below |
| 5989 | 6.18.2 Necessary out let and inlet connection pipes shall provided. |
| 5990 | CAP BILL N0. 6.19. PROVIDINGAPPROACH ROAD TO Balancing cum GLSR ON VEERABADRAKONDA & SHESU KONDA. |
| 5991 | 6.19.1 Earth work excavation and depositing on bank with an initial lead of 10 mts and lift of 2 mts for loamy, clayey soils like black cotton soils, all taxes,red earth, ordinary gravel,soils includingcost and conveyance of alllabour charges etc., complete as per SSandas directed by the departmental officer in charge of the work for foundations of the building |
| 5992 | 6.19.2 Earthwork excavation and depositing on bank in Hard rock and boulders more than 3 Cum in sizeas per specification drawing and as directed by departmental officers |
| 5993 | 6.19.3 Supply and spreading of quarry dust including watering, tampingincluding cost and conveyance of all materials and labour charges etc complete |
| 5994 | 6.19.4 Vibrated cement concrete M 30 using graded HBG metal including cost and conveyance of all materials land labour charges for centering, machine mixing, laying, vibrating and curing etc. including all other incidental charges of all T&P etc. for finished item of work as per MoRTH apecifications 1500, 1700, 2100 and 2702 and as directed by the depermental engineers in charge. RBR - FNDN Vol 3 |
| 5995 | CAP BILL N0. 6.20. CONSTRUCTION OF COMPOUND WALLS TO PUMPING STATION AT 1100KL GLSR AT VERABHADRAM KONDA & 300KL GLSR IN SHESHU KONDA. |
| 5996 | 6.20.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width (RBR-FNDN-1) |
| 5997 | 6.20.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 5998 | 6.20.3 Plain cement concrete in (1:4:8) prop using 40 mm nominal size hard brokenmachine crushed granite metal as per SS including cost and conveyance of all materials, seignarage, sales taxand labour charges such as mixing concrete, laying, tamping, curing all operational, incidental charges etc., complete as per SSfor finished item of work for building foundation concrete. |
| 5999 | 6.20.4 (BLD-CSTN 2-15) - RCC M- 25 DESIGN mix corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal from approved quarry including cost and conveyance of all materials like cement, fine aggregate,coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges including centering, shuttering, machine mixing, laying concrete, vibrating, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work. |
| 6000 | Column footings |
| 6001 | Plinth beam |
| 6002 | Columns |
| 6003 | Beam over compound wall |
| 6004 | 6.20.5 Suply of HYSD Fe 415 grade steel including cost and conveyance to site and labour charges including cutting, bending, binding, fabrication of reinforcementincluding cost of binding wire etc. complete for reinforcement |
| 6005 | 6.20.6 Brick masonryin cement mortor (1:6) proportion using 2nd class bricks . This rateis includingcost and conveyanceof materials to site, seigniorage fee,all taxes, lifting charges, mixing of cement mortar, all labour charges,watering, curing, including all scaffolding and all water lead charges etc., complete as per SS and as directed by the departmental officer in charge of the work for |
| 6006 | 6.20.7 Plastering 12mm thick with cement mortar CM (1:4) including cost and conveyanceof all materials to site and seignorage fee, screening and mixing, laying, scoffolding, liftingand watering, curing including all labour charges, hire and operational charges and all taxes etc., complete as per SS and as directed by the departmental officer in charge of the work for the following item of work for Ground Floor |
| 6007 | 6.20.8 Painting walls with snow cem paint of good quality of approved colour over primary coat of cement primer including cost, and conveyance of all materials to site, taxes using brushes and including all required materials , watering charges all labour charges, scoffolding charges, lifting chargesoperational charges etc., complete for finished item of work and as directed by the departmental officer in charge of the work. |
| 6008 | 6.20.19 Provding suitable arnamental MS gates including cost of fixing and painting the gate with suitable paits over two coats of red oxide and all other materials required as per the approved drawing and as directed by the departmental engineers in charge. |
| 6009 | 6.20.11 Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately) |
| 6010 | CAP BILL N0. 6.21. CONSTRUCTION OF Staff Quarters and Watchmen Quarters |
| 6011 | at yerravaram |
| 6012 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6013 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6014 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6015 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6016 | 6.21.4.1 column footings |
| 6017 | 6.21.4.2 Columns |
| 6018 | 6.21.4.3 Plinth beam |
| 6019 | 6.21.4.4 Lintle beamsWindows |
| 6020 | 6.21.4.5 Roof Beams |
| 6021 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6022 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6023 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6024 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6025 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6026 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6027 | 6.21.7.1 ground floor |
| 6028 | 6.21.7.2 1st floor |
| 6029 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6030 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6031 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6032 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6033 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6034 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6035 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6036 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6037 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6038 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6039 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6040 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6041 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6042 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6043 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6044 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6045 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6046 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6047 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6048 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6049 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6050 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6051 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6052 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6053 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6054 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6055 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6056 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6057 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6058 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6059 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6060 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6061 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6062 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6063 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6064 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6065 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6066 | 6.21.40- S&F of GI & GM fittings |
| 6067 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6068 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6069 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6070 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6071 | 6.21.40.5 - S& F GI union Ist Quality |
| 6072 | A.12.70mm |
| 6073 | B.19.05mm |
| 6074 | C.25.40mm |
| 6075 | FOR SEPTIC TANK |
| 6076 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6077 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6078 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6079 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6080 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6081 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6082 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6083 | 1 No Say |
| 6084 | at Veerabhdra konda |
| 6085 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6086 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6087 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6088 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6089 | 6.21.4.1 column footings |
| 6090 | 6.21.4.2 Columns |
| 6091 | 6.21.4.3 Plinth beam |
| 6092 | 6.21.4.4 Lintle beamsWindows |
| 6093 | 6.21.4.5 Roof Beams |
| 6094 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6095 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6096 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6097 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6098 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6099 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6100 | 6.21.7.1 ground floor |
| 6101 | 6.21.7.2 1st floor |
| 6102 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6103 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6104 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6105 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6106 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6107 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6108 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6109 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6110 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6111 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6112 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6113 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6114 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6115 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6116 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6117 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6118 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6119 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6120 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6121 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6122 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6123 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6124 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6125 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6126 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6127 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6128 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6129 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6130 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6131 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6132 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6133 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6134 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6135 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6136 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6137 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6138 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6139 | 6.21.40- S&F of GI & GM fittings |
| 6140 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6141 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6142 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6143 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6144 | 6.21.40.5 - S& F GI union Ist Quality |
| 6145 | A.12.70mm |
| 6146 | B.19.05mm |
| 6147 | C.25.40mm |
| 6148 | FOR SEPTIC TANK |
| 6149 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6150 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6151 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6152 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6153 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6154 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6155 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6156 | At Head water works |
| 6157 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6158 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6159 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6160 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6161 | 6.21.4.1 column footings |
| 6162 | 6.21.4.2 Columns |
| 6163 | 6.21.4.3 Plinth beam |
| 6164 | 6.21.4.4 Lintle beamsWindows |
| 6165 | 6.21.4.5 Roof Beams |
| 6166 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6167 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6168 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6169 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6170 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6171 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6172 | 6.21.7.1 ground floor |
| 6173 | 6.21.7.2 1st floor |
| 6174 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6175 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6176 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6177 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6178 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6179 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6180 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6181 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6182 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6183 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6184 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6185 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6186 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6187 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6188 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6189 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6190 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6191 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6192 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6193 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6194 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6195 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6196 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6197 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6198 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6199 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6200 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6201 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6202 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6203 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6204 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6205 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6206 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6207 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6208 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6209 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6210 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6211 | 6.21.40- S&F of GI & GM fittings |
| 6212 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6213 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6214 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6215 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6216 | 6.21.40.5 - S& F GI union Ist Quality |
| 6217 | A.12.70mm |
| 6218 | B.19.05mm |
| 6219 | C.25.40mm |
| 6220 | FOR SEPTIC TANK |
| 6221 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6222 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6223 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6224 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6225 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6226 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6227 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6228 | at Seshukonda |
| 6229 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6230 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6231 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6232 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6233 | 6.21.4.1 column footings |
| 6234 | 6.21.4.2 Columns |
| 6235 | 6.21.4.3 Plinth beam |
| 6236 | 6.21.4.4 Lintle beamsWindows |
| 6237 | 6.21.4.5 Roof Beams |
| 6238 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6239 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6240 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6241 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6242 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6243 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6244 | 6.21.7.1 ground floor |
| 6245 | 6.21.7.2 1st floor |
| 6246 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6247 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6248 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6249 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6250 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6251 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6252 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6253 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6254 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6255 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6256 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6257 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6258 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6259 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6260 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6261 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6262 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6263 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6264 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6265 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6266 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6267 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6268 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6269 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6270 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6271 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6272 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6273 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6274 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6275 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6276 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6277 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6278 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6279 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6280 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6281 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6282 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6283 | 6.21.40- S&F of GI & GM fittings |
| 6284 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6285 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6286 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6287 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6288 | 6.21.40.5 - S& F GI union Ist Quality |
| 6289 | A.12.70mm |
| 6290 | B.19.05mm |
| 6291 | C.25.40mm |
| 6292 | FOR SEPTIC TANK |
| 6293 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6294 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6295 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6296 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6297 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6298 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6299 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6300 | at Pedapalli |
| 6301 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6302 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6303 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6304 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6305 | 6.21.4.1 column footings |
| 6306 | 6.21.4.2 Columns |
| 6307 | 6.21.4.3 Plinth beam |
| 6308 | 6.21.4.4 Lintle beamsWindows |
| 6309 | 6.21.4.5 Roof Beams |
| 6310 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6311 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6312 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6313 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6314 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6315 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6316 | 6.21.7.1 ground floor |
| 6317 | 6.21.7.2 1st floor |
| 6318 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6319 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6320 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6321 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6322 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6323 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6324 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6325 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6326 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6327 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6328 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6329 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6330 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6331 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6332 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6333 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6334 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6335 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6336 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6337 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6338 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6339 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6340 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6341 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6342 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6343 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6344 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6345 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6346 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6347 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6348 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6349 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6350 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6351 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6352 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6353 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6354 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6355 | 6.21.40- S&F of GI & GM fittings |
| 6356 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6357 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6358 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6359 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6360 | 6.21.40.5 - S& F GI union Ist Quality |
| 6361 | A.12.70mm |
| 6362 | B.19.05mm |
| 6363 | C.25.40mm |
| 6364 | FOR SEPTIC TANK |
| 6365 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6366 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6367 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6368 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6369 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6370 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6371 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6372 | At kokkirapalli |
| 6373 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6374 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6375 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6376 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6377 | 6.21.4.1 column footings |
| 6378 | 6.21.4.2 Columns |
| 6379 | 6.21.4.3 Plinth beam |
| 6380 | 6.21.4.4 Lintle beamsWindows |
| 6381 | 6.21.4.5 Roof Beams |
| 6382 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6383 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6384 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6385 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6386 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6387 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6388 | 6.21.7.1 ground floor |
| 6389 | 6.21.7.2 1st floor |
| 6390 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6391 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6392 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6393 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6394 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6395 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6396 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6397 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6398 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6399 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6400 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6401 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6402 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6403 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6404 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6405 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6406 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6407 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6408 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6409 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6410 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6411 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6412 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6413 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6414 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6415 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6416 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6417 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6418 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6419 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6420 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6421 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6422 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6423 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6424 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6425 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6426 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6427 | 6.21.40- S&F of GI & GM fittings |
| 6428 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6429 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6430 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6431 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6432 | 6.21.40.5 - S& F GI union Ist Quality |
| 6433 | A.12.70mm |
| 6434 | B.19.05mm |
| 6435 | C.25.40mm |
| 6436 | FOR SEPTIC TANK |
| 6437 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6438 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6439 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6440 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6441 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6442 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6443 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6444 | At Dharmavaram |
| 6445 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6446 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6447 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6448 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6449 | 6.21.4.1 column footings |
| 6450 | 6.21.4.2 Columns |
| 6451 | 6.21.4.3 Plinth beam |
| 6452 | 6.21.4.4 Lintle beamsWindows |
| 6453 | 6.21.4.5 Roof Beams |
| 6454 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6455 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6456 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6457 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6458 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6459 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6460 | 6.21.7.1 ground floor |
| 6461 | 6.21.7.2 1st floor |
| 6462 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6463 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6464 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6465 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6466 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6467 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6468 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6469 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6470 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6471 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6472 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6473 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6474 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6475 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6476 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6477 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6478 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6479 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6480 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6481 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6482 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6483 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6484 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6485 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6486 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6487 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6488 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6489 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6490 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6491 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6492 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6493 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6494 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6495 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6496 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6497 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6498 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6499 | 6.21.40- S&F of GI & GM fittings |
| 6500 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6501 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6502 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6503 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6504 | 6.21.40.5 - S& F GI union Ist Quality |
| 6505 | A.12.70mm |
| 6506 | B.19.05mm |
| 6507 | C.25.40mm |
| 6508 | FOR SEPTIC TANK |
| 6509 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6510 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6511 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6512 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6513 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6514 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6515 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6516 | At Ramarayudupalem |
| 6517 | 6.21.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places |
| 6518 | 6.21.2 RBR-FNDN-2. Supply and filling with quarry dustfrom approved quarry including cost and conveyaance, watering, tamping including all labour charges |
| 6519 | 6.21.3 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6520 | 6.21.4 Supply and placing of the design mix concretecorresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such asweigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating,curing etcM25 design mix |
| 6521 | 6.21.4.1 column footings |
| 6522 | 6.21.4.2 Columns |
| 6523 | 6.21.4.3 Plinth beam |
| 6524 | 6.21.4.4 Lintle beamsWindows |
| 6525 | 6.21.4.5 Roof Beams |
| 6526 | 6.21.4.6 Roof slab0.125m thick with 0.30m extension all sides |
| 6527 | 6.21.4.7 Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows |
| 6528 | 6.21.4.8 Loft slab 0.075m thick kitchen |
| 6529 | 6.21.5 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss ( Ground Floor) |
| 6530 | 6.21.6 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss (1st floor) |
| 6531 | 6.21.7 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6532 | 6.21.7.1 ground floor |
| 6533 | 6.21.7.2 1st floor |
| 6534 | 6.21.8 Cement plasteringusing opc in cm(1:3) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height |
| 6535 | 6.21.9 Colourwashing two coats using snowcem over the primery coatconveyance of all labour charges etc., complete as per (in and out side) |
| 6536 | 6.21.10 Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss |
| 6537 | 6.21.11 Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/greenglass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6538 | 6.21.11.1 Door -D - 1.20X2.10 m |
| 6539 | 6.21.11.2 DoorsD1 -1.00X2.10m |
| 6540 | 6.21.12 Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work |
| 6541 | 6.21.13 Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work |
| 6542 | 6.21.14 Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work |
| 6543 | 6.21.15 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6544 | 6.21.16 Cement plasteringusing opc in cm(1:3) prop 20 mmthick including cost of material, labour ,curing etc. complete as per SSfor floorring |
| 6545 | 6.21.17 Manufacture,supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete |
| 6546 | 6.21.18 Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per ss |
| 6547 | 6.21.19 Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brandfor rain water pipes with clamps |
| 6548 | 6.21.20 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6549 | 6.21.21 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6550 | 6.21.22 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building |
| 6551 | 6.21.23 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges |
| 6552 | 6.21.24 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6553 | 6.21.25 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6554 | 6.21.26supply andrun of 2 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6555 | 6.21.27 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6556 | 6.21.28 S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc-- 63 AFP isolator-1 no for incomer,6-32ASPMCBS -18 Nos for out going |
| 6557 | 6.21.29 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6558 | 6.21.30 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6559 | 6.21.31 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6560 | 6.21.32 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size |
| 6561 | 6.21.33 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock |
| 6562 | 6.21.34 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6563 | 6.21.35 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6564 | 6.21.36 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6565 | 6.21.37 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6566 | 6.21.38 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6567 | 6.21.39 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6568 | 6.21.39.1 - 25 mm dia nominal bore -from tank to jn forof individual lines |
| 6569 | 26.21.39.2 - 20 mm dia nominal bore -fromjn forof individual lines to toilets & Kitchen |
| 6570 | 6.21.39.3 - 15 mm dia nominal bore -for internal |
| 6571 | 6.21.40- S&F of GI & GM fittings |
| 6572 | 6.21.40.1 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6573 | 6.21.40.2 GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6574 | 6.21.40.3-GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6575 | 6.21.40.4 - S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6576 | 6.21.40.5 - S& F GI union Ist Quality |
| 6577 | A.12.70mm |
| 6578 | B.19.05mm |
| 6579 | C.25.40mm |
| 6580 | FOR SEPTIC TANK |
| 6581 | 6.21.41 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH Note : Classifications of Earth Work Specification are as per 302.2.1(a) of MORD and 301.2.1 of MORT&H--ordinary soil--manual means upto 3m depth for foundations |
| 6582 | 6.21.42 Filling with Crusher dust in foundations /pipe linetrenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH |
| 6583 | 6.21.43 Providing PCC 1:4:8using 40 mm graded SS 5HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materialsand labour charges, machine mixing , vibration,laying in position, curing etc., complete |
| 6584 | 6.21.44 Brick work in CM 1:6 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 daysetc complete as per ss |
| 6585 | 6.21.45 Cement plasteringusing opc in cm(1:5) prop 12 mmthick including cost of material, labour ,curing etc. complete as per SS out side & inside |
| 6586 | 6.21.46 RCC M-25 design mix (cement,fine aggregate,coarse aggregate) corresponding to Table -9 of IS -456 using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work,but including centering,shutteringfor cover slabs |
| 6587 | 6.21.47 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. |
| 6588 | CAP Bill No 6.22 Hiring for 1 Nos. Vehicles for 24 Months on execution period. 1 Nos. x 24 x Rs.35000 per Month.(2 Years x 12 Months =24 Months) |
| 6589 | Hiring for 1 Nos. Vehicles for 24 Months on execution period. 1 Nos. x 24 x Rs.35000 per Month.(2 Years x 12 Months =24 Months) |
| 6590 | CAP Bill No 6.23 Construction of Local SCADA Room |
| 6591 | 6.23.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for Manual Means. |
| 6592 | 6.23.2 Supply and filling with Quary dustcomplying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work (APDSS No.101). |
| 6593 | 6.23.3 Laying Cement concrete (1:4:8)using 40mm nominal size HBG metal M/C including cost and conveyance of all materials from approved quarry, machine mixing, vibrating, laying, levelling, ramming, curing and labour charges etc., complete. As per APSS 402 (BLD-CSTN-2-5). |
| 6594 | 6.23.4 Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work. |
| 6595 | 6.23.5 Plain Cement concrete (M 25) Nominal Mix using 20mm metal using concrete mixer including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, centering, shuttering etc.,complete for Bed. |
| 6596 | 6.23.6 Plain Cement concrete (M 25) Nominal Mix using 20mm metal using concrete mixer including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, centering, shuttering etc.,complete For Side Walls of Septic Tank. |
| 6597 | 6.23.7 BLD-CSTN-3-14-(31)-C : Supply and placing of the M-30 Design Mix Concrete corresponding to IS 456 using WEIGH BATCHER / MIXER with 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work(APSS No. 402)with minimum cement content as per IS code from standard suppliers approved by the department including pumping, centering, shuttering, laying concrete, vibrating, curing etc. complete but excluding cost of steel and its fabrication charges for finished item of work. for RCC SLABS, BEAM |
| 6598 | 6.23.7.1 - FOOTINGS |
| 6599 | 6.23.7.2 - Pedestal around columns |
| 6600 | 6.23.7.3 - Columns upto Plinth |
| 6601 | 6.23.7.4 - Plinth beam |
| 6602 | 6.23.7.5 - Columns upto ground floor roof level |
| 6603 | 6.23.7.6 - Columns upto first floor roof level |
| 6604 | 6.23.7.7 - Columns upto second floor roof level |
| 6605 | 6.23.7.8 - Beams |
| 6606 | 6.23.7.9 - LINTELS |
| 6607 | 6.23.7.10 - Sunshades |
| 6608 | 6.23.7.11 - Stair case Slab 0.15 m thick |
| 6609 | 6.23.7.12 - RCC Slab 150 mm thick |
| 6610 | 6.23.8 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) for pre cast slabs of culverts- RBR-FNDN-8 & Revised Data sl.No-5 |
| 6611 | 6.23.9 Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work (BLD-CSTN-3-1). |
| 6612 | 6.23.9.1 - For Ground Floor |
| 6613 | 6.23.9.2 - For First Floor |
| 6614 | 6.23.9.3 - For Second Floor |
| 6615 | 6.23.10 Plastering with CM (1:3) 12mm thick GF to ceiling unit 10.00 sqmBLD-CSTN-6-1 |
| 6616 | 6.23.11 Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. ( For ground,first & second floor ) |
| 6617 | 6.23.12 Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc.,complete for finished item of work. ( For Inside walls & ceiling ) |
| 6618 | 6.23.13 Flooring with 50 mm thick Rough Cuddapah/Shabad stones, set over base coat of cement mortar (1 : 8) 12 mm thick over CC bed already laid or RCC roof slab, including pointing with cement mortar 1:3 duly filling joints nearly, including cost of all materials like flooring stone, cement, sand, and water etc., complete, including seigniorage charges,labour charges for dressing of flooring stones etc., complete for finished item of work, but excluding the cost of conveyance of all materials. |
| 6619 | 6.23.14 Flooring with ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials.( for toilets) |
| 6620 | 6.23.15 Dadooing to walls with first quality glazed coloured tiles approved colour of any size set over base coat of C.M(1:3)prop. 12mm thick and neat grey cement slurry of honey like consistency spread at the rate of 3.3Kg of cement per sqm and jointed with neat white cement paste at 0.20 kg per sqm mixed with pigment of matching shade to match the shade of tiles including cost and conveyance of all materials labour charges, water to work site,seignourage and all operational .incidental , mixing mortar , fixing inposition ,lift charges, curing etc., complete as per SS or as directed by the departmental authorities for finished item of work.(for toilets) |
| 6621 | 6.23.16 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) (outside) |
| 6622 | 6.23.17 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) (inside toilets & all floors scada rooms) |
| 6623 | 6.23.18 Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) pure polyester powder upto 50-60 microns thick, outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the equired rigidity and effective acoustic insulation with 6” Tower bolt – 1 No., 6” D handles – 2 Nos., 10” Aldrop – 1 No., Butt Hinges – 3 Nos, Mortise Lock of approved quality – 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws complete for finished item of work for Single leaf Door |
| 6624 | 6.23.19 Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6\" pitch complete for finished item of work. |
| 6625 | 6.23.20 Providing & fixing 30 mm thick solid panel PVC door shutter consisting of frame made out of 19 guage M.S tube of 19 x 19 mm for stiles, top & bottom rail, with a coat of primer of approved make. M.S. Frame covered with 5 mm thick heat moulded PVC “C” channel of size of 30 x 50 mm forming stiles, 5 mm thick 75 mm wide PVC sheet for top, lock & bottom rail on either side 20 mm wide cross PVC sheet as gap insert for top & bottom rail, panelling of 10mm(+/-)( 5mm+5mm)” thick PVC sheet fitted in the M.S. frame welded /sealed to the stiles, on either side joined together with solvent cement adhesive etc., additional 5 mm thick PVC strip of 20 mm width stuck on the interior side of the C channel using solvent cement, complete as per direction of Engineer–in–charge, manufacturers specification. (SoR 2018-19, BMT-N.51). |
| 6626 | 6.23.21 Ventilators: Top Hung 2 \"-0\" x 2\"-0\" (609.6x609.6mm) outer frame section size of 46mm x 52 mm shutter frame section size of 46mm x 46 mm |
| 6627 | 6.23.22 Providing and fixing Thermocole False ceiling in true horizontal level 600 mm x 600 mm using 15 mm/ 19 mmthick Thermocole sheet anodised Aluminium Tee sections of size 24.50 mm x 24.0 mm x 2.4 mm in grid with cross tee of size 24 x 24.5 mm at every 600 mm c/c and anodised aluminium wall angle of size 24 x 24 mm fixed to periphery of the wall and the above grid is suspended at every 1200 mm c/c in both directions using 2.0 mm thick GI Wire for finished of size 600 x 600 mm including Cost &conveyance of all materials and labour charges such as cutting , fixing of standing of frame work exposing roof making complete for finished item of work |
| 6628 | 6.23.23 PROVIDING ELECTRIFICATION |
| 6629 | 6.23.23.1 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6630 | 6.23.23.2 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6631 | 6.23.23.3 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complete for light, bell , fan and exhaust fan points in non - residential building |
| 6632 | 6.23.23.4 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6633 | 6.23.23.5 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6634 | 6.23.23.6 supply andrun of 4 of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6635 | 6.23.23.7 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6636 | 6.23.23.8 Supply and fixing TPN Distribution board with IP-30 protection suitable for 3 phase ELCB / RCCB / FP Isolator as incomer and 10kA SP MCBs as outing going including internal connection and labour charges for surface / flush mounting etc., complete.BLD-ELEC-4.4.3 |
| 6637 | 6.23.23.9 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6638 | 6.23.23.10 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6639 | 6.23.23.11 Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs. |
| 6640 | 6.23.23.12 Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 6641 | 6.23.23.13 Labour charges Fixing of 40W tube light luminaire on wall / Ceiling with/ TW round blocks with all accessories including giving connections and all labour charges etc., complete. |
| 6642 | 6.23.23.14 Supply and fixing of 16A 3/2 pin flush type wall plug modular socket with shutter and 16A modular switche controll on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete. Makes of Switches : GM G Home /Anchor Penta Cherry / Gold Madel Olive / Million Zoom / Great White |
| 6643 | 6.23.23.15 Supply of ...............INVERTER Model Cool type split AC unit with highwall mounted Single Split indoor unit and outdoor condensing unitHermetically sealed compressor suitable for operation on 230V, 50Hz,1Phase AC supply capable of performing Heat cool dehumidifying aircirculating and filtering with cooling and condensing units with 3 mts ofcopper piping, insulation kit and 4 mts of 4 core copper flexible chordwith cordless remote control etc., dual barrier coating in order to protect 2.0TR, 5 Star capable of delivering not lessthan 21600 BTU/hr and above with operating onrefrigerant R-410A / R-32Makes: As per list of recommended brands ascategory II.coil form oxidation with copper condenser. |
| 6644 | 6.23.24 WS and Sanitery arrengements |
| 6645 | 6.23.24.1 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks |
| 6646 | 6.23.24.2 Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of work |
| 6647 | 6.23.24.3 SSupplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 30mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work |
| 6648 | 6.23.24.4 Supplying and fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit complete for finished item of work for all floors |
| 6649 | 6.23.24.5 Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. |
| 6650 | 6.23.24.6 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) |
| 6651 | 6.23.24.7 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand |
| 6652 | 6.23.24.8 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice |
| 6653 | 6.23.24.9 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg |
| 6654 | 6.23.24.10 S& F GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete |
| 6655 | A.)25 mm dia nominal bore -from tank to jn forof individual lines and inlet |
| 6656 | B) 20 mm dia nominal bore -fromjn forof individual lines to toilets |
| 6657 | C) 15 mm dia nominal bore -for internal |
| 6658 | 6.23.24.11 S&F of GI & GM fittings |
| 6659 | A) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size |
| 6660 | B) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size |
| 6661 | C) GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size |
| 6662 | 6.23.24.12 S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent |
| 6663 | 6.23.24.13 S& F GI union Ist Quality |
| 6664 | A) 12.70mm |
| 6665 | B) 19.05mm |
| 6666 | C) 25.40mm |
| 6667 | 6.23.25 Carting away the surplus excavated materialsi.e., earthfrom the site to a suitable distance of about 5 kms including loading, unloading, conveyance charges and dumping the carted materials at the contractors cost, labour charges, all leads and lifts, all other incidental and operational charges etc complete |
| 6668 | 6.23.26 Provding suitable arnamental MS gates including cost of fixing and painting the gate with suitable paits over two coats of red oxide and all other materials required as per the approved drawing and as directed by the departmental engineers in charge |
| 6669 | 6.23.27 Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately) |
| 6670 | CAP Bill No 6.24. - 24X7 Water Supply - CENTRAL SCADA Systems - Supply and fixing ofinstallation of instrumentation & automation of pumping station & reservoir inlet management , water supply DMA managementwhich includes Flowmeters, AMIwater meter managementLocal SCADA control station Motorised Valves, Level Indicators including Supervisory Control and Data Acuasation System (SCADA) for controlling and monitoring of the bulk water supply pipelines for Yelamanchili Varaha RIver.( AT VIZAG PUBLIC HEALTH - CIRCLE LEVEL ) |
| 6671 | PUMPING SYSTEM |
| 6672 | 6.24.1 Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications ofWater Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 6673 | 6.24.2 Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6674 | 6.24.3 Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE.Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer |
| 6675 | 6.24.4 Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 6676 | 6.24.5 Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 6677 | 6.24.6 Supply and testing of wall mounted120(w),140(H),77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 6678 | 6.24.7 Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS,Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 6679 | 6.24.8 Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes |
| 6680 | 6.24.9 Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6681 | 6.24.10 Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow & Pressure and QualityParameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 6682 | 6.24.11 Supply, errection, Testing & Commissioning of In door type Scadabased RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB\"s, Relay cards, fixing of all termination with FTB\"s, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables,and the panel having logic for the following anderection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 6683 | RESERVOIR INLET MANAGEMENT |
| 6684 | 6.24.12 supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation. |
| 6685 | 6.24.12.1 - 100MM Dia Above Specification. |
| 6686 | 6.24.12.2 - 150 MM Dia Above Specification. |
| 6687 | 6.24.12.3 - 200 MM Dia Above Specification. |
| 6688 | 6.24.12.4 - 300 MM Dia Above Specification. |
| 6689 | 6.24.13 Supply and deliveryof separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 6690 | 6.24.13.1 - 100MM Dia Above Specification. |
| 6691 | 6.24.13.2 - 150 MM Dia Above Specification. |
| 6692 | 6.24.13.3 - 200 MM Dia Above Specification. |
| 6693 | 6.24.13.4 - 300 MM Dia Above Specification. |
| 6694 | 6.24.14 Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 6695 | 6.24.14.1 - 100MM Dia Above Specification. |
| 6696 | 6.24.14.2 - 150 MM Dia Above Specification. |
| 6697 | 6.24.14.3 - 200 MM Dia Above Specification. |
| 6698 | 6.24.14.4 - 300 MM Dia Above Specification. |
| 6699 | 6.24.15 Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6700 | 6.24.15.1 - 100MM Dia Above Specification. |
| 6701 | 6.24.15.2 - 150 MM Dia Above Specification. |
| 6702 | 6.24.15.3 - 200 MM Dia Above Specification. |
| 6703 | 6.24.15.4 - 300 MM Dia Above Specification. |
| 6704 | 6.24.16Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensorsmake of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth,protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6705 | 6.24.17 Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 6706 | 6.24.18 Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7),Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes. |
| 6707 | 6.24.19 Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6708 | 6.24.20 Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer |
| 6709 | 6.24.21 Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6710 | 6.24.22 Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6711 | 6.24.23 Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6712 | 6.24.24 Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6713 | 24 x 7 Water Supply ::DMA Management :: |
| 6714 | 6.24.25 supply and delivery of \"Resilient Seated Soft Sealing\" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation |
| 6715 | 6.24.26 Supply and deliveryof Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 6716 | 6.24.27 Supply and delivery ofElectrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit tofunctions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SSincluding cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department offic |
| 6717 | 6.24.28 Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6718 | 6.24.29 Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA/ Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officer |
| 6719 | 6.24.30 Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe Control &Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valveswith specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panelis suitable forthe above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer. |
| 6720 | 6.24.31 Supply laying and jointing of 4 Sq.MM - 2 corePVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR\"s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6721 | 6.24.32 Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cablemake of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automationat Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and everypanel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6722 | 6.24.33 Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece,lifting the said pipe, cleaning & returning to the departmental storeas per direction of the Engineer-in-charge andlowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,)charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6723 | 6.24.34 Providing, Installing and satisfactory field testing of Self Powered Pressure Monitoring Sensor with the specifications of DN 10, PN 0 to PN 16 range, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, protection class of IP-68, 3.6 V.. DC, Lithium Battery, Life of 3 Yeras basis on six transmissions per day.The meter can fetch the pressure datain minimum 1 Minute interval (User selectable) and store the data up to 300 Logs with time stamp on FIFO basis with in the Meter and transmit data through JSON format to the data server via NB IoT/LoRa/LoRawan communication and the data management system can able to process the Pressure data to display as per the time stamp and generate the trends as per the user defined vaiables and fixing with suitable manifold including stop cocks etc., complete charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. |
| 6724 | 6.24.35 Integration ofPLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer. |
| 6725 | AMI Water Meter Management. |
| 6726 | 6.24.36 Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-A. |
| 6727 | 6.24.37 Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoTin every 24 Hours without fail through the provider registered inDOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication)The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warrantiesand submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.Note: Detailesd technical specifications enclosed as Anexure-B |
| 6728 | 6.24.38 Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer. |
| 6729 | Local SCADA Control Sation: |
| 6730 | 6.24.39Supply,erection, testing, commissioning of Hard ware for the SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter managementwhere the instrumantation and automation developed under this project and synchornization by deploying the followingcomponents including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. |
| 6731 | 6.24.40 Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control stationwhere the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMAand AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. |
| 6732 | Central Station at Vizag Circle Level YELAMNCHILI : |
| 6733 | 6.24.41 Supply,erection, testing, commissioning of Hard ware for the SCADA system for Central control stationwhere the SCADA room will be developed by the local Circle for operting & View from Service Reservoirs, DMAand AMI meter management for entire circle where the instrumantation and automation developed under this project and synchornization by deploying the followingcomponents including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. |
| 6734 | 6.24.42 AMR Water Meter Management System: Providing, deploy and Run the AMR software to collect the data from all AMR integrated Mechanical water Meters Installed in field with the specifications of provide mobile app to get the field data of consumer including geo mapping to synchronize with AMR software, the AMR software must have the capability to decrypt the received data from water meter and ensure data integrity, the software shall give output, at least in the CSV (Comma Separated Value)/ txt/ xls format,the AMR software must be capable of running on any standard PC/ MAC/Android/iOS devices, the AMR software should be cloud based and should have web portal access so that user can view customer data through browser, the AMR software should have an option for individual customer to view their meter consumption data through Web portal/ Mobile APP of Android or iOS, the AMR software shall allow the PC operator to review and edit any account in the AMR software, the AMR software should have the facility to export CSV/Txt/xls files in the pre-defined format by utility to billing system, the AMR software shall enable the client to specify the data to be exported from the database for transferring to billing system, the AMR Software shall be able to show meter status as meter not okay, reading not reliable, meter maintenance required etc., the AMR software should have capability to add additional customer information and create customizable data fields, the AMR software should manage GPS data of AMR Meters, the AMR Software have facility to generate customized MIS reports, the AMR software can store the historical data up to minimum two years, the AMR software have to generate the alarms /alerts regarding abnormalities of the Water Meter, the AMR software have data integrity feature with standard industrial security protocol, the Mobile App having the facility to configure the AMR water meter via Bluetooth, the AMR software have facility to generate the NRW reports by synchronizing the data from SCADA software, the AMR software have facility to generate the Consumption/Billing alerts via SMS / What’s App / e-Mail, AMR software needs to follow responsive software guidelines by Indian government, AMR software should have an option to create multiple users, AMR software should implement permission managemtnt for users - so that user can access only permitted Modules / Screens, AMR software should have Block IP mechanism, AMR software has to protected from DDOS attacks, AMR software should be implemented with Less latency standard industrial technologies, the information transfer from database to application should be done in a secured channel charges including cost and convayance of all material and labor excluding cost of taxes and dutiesand as per SS and as directed by the department officerNote: Detailesd technical specifications enclosed as Anexure-C |
| 6735 | 6.24.43 Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Central control stationwhere the SCADA room will be developed by the Circle for operting & View from Service Reservoirs, DMAand AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks,etc., complete and as directed by the department officer. |
| 6736 | CAP Bill No 6.25.Construction of Central Monitoring Station for SCADA Operations at Public Health Vizag circleoffice premices (Separarte estimate) |
| 6737 | 6.25.1 Pre construction Anti termite treatment is a process in which chemical toxic to subterrean tremites is apply/ inject into soil during early stage of building Construction 2. Treatement of soil Beneath the building and around the foundations conduct and chemical use as per BIS - IS 6313 (Part -2) 2013 code specification & CIB RC registered termiticide which creates a continuous chemical barrier beneath the building which kills or repels terminates & impervious to tremite entry 3. Imidacloprid 30.5% SC (IS 63131) dissolve 2.1 Ml/1 liter of water and apply emulsion/solution @ 7.5 Litres/Square meter (Sqm) of internal, external vertical surface of the colums, plinth beams (Back filling) walls and floor junction, external perimeters, along reatining wall @ 5.0 Liters/Sqm of the horizontal surface of basement top surface of the basement filling below flooring bed (Plinth) & @ 2.0 Litres/ Line meter at expansion joints. The substructure of a depth of 500mm around coulmns & 300mm deep around plinth beams, basements & floor filling area including excavation channel along the wall & rodding etc. cost & Conveyance of all materials to the site, cost of labour for sparying, rodding, overheads and contractor profit etc. complete for furnished item of work as per the approval of the Engineer-in-chargeBMT-H. 66 |
| 6738 | 6.25.2 Earth work excavation for foundations (Manual Means) of buildings,septic tank, sump, compound wallin ordinary soils and depositing on bank with an initial lead of 10m and depth up to 3m including all operational,incidental, labour charges such as shoring, sheeting, planking, strutting etc., and complete for finished item of work excluding dewatering charges etc., as per SS 20 B(APSS 308) |
| 6739 | 6.25.3 Filling in foundation trenches with stone dustas per drawing and technical specification Clause 305.3.9 MORD & 304 MORTHfor foundations of cc drains and pipe line trenchRBR-FNDN-2(1)Unit 1.00 cum |
| 6740 | 6.25.4 Filling in foundation trenches with Gravel as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTHfor foundations of cc drains and pipe line trenchRBR-FNDN-2(1)Unit 1.00 cum |
| 6741 | 6.25.5 Filling with useful available excavated earth (excluding rock) with a lead of 50 m in trenches, sides of foundations and basement with initial lead in layers not exceeding 15cm thick, watering and ramming including cost and conveyance of water to work site and all operaitonal, incidental, labour charges, hire charges of T&P etc.,and overheads & contractors profit complete for fnished item of work (APSS NO.309&310) |
| 6742 | 6.25.6 Plain Cement Concrete(1:4:8) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm sizehard , machine crushedgranite from approved quarry including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site, sales & other taxes on all materials and including all charges for machine mixing, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,and complete for finished item of work. (APSS No. 402) |
| 6743 | 6.25.7 Random Rubble stone masonry in CM (1:8) prop: (Cement: Sand) using hard other than granitestonescarted from approved quarry including cost and conveyance of all materials like cement, screened sand, water, stones etc., from approved quarry, to site, including labour for cutting stones to required size and shape, mixing, of cement, mortar, construction,curing etc.,and overheads & contractors profitcomplete for finished item of work in foundation and basement. (APSS No. 601 & 615 |
| 6744 | 6.25.8 Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 200ml per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profitcomplete for finished item of work. (APSS No. 901 & 903). |
| 6745 | 6.25.9 Brick masonary in CM (1:5) with traditional size23x11x7cm unit 1.00 cum |
| 6746 | 6.25.9.1 Ground floor |
| 6747 | 6.25.9.2 First floor |
| 6748 | 6.25.10 Plastering with CM (1:4) 12mm thick GF unit 10.00 sqm BLD-CSTN-6-2 |
| 6749 | 6.25.10.1 Ground floor |
| 6750 | 6.25.10.2 First floor |
| 6751 | 6.25.11 Plastering 20mm thick single coat in CM(1:3) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) |
| 6752 | 6.25.11.1 Ground floor |
| 6753 | 6.25.11.2 first floor |
| 6754 | 6.25.12 Plastering with CM (1:3) 12mm thick GF to ceiling unit 10.00 sqmBLD-CSTN-6-1 ( G.F & F.F) |
| 6755 | 6.25.13 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours)BLD-CSTN-10-3 {For Internal walls} |
| 6756 | 6.25.14 Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours)BLD-CSTN-10-3 {For External walls} |
| 6757 | 6.25.15 Flooring with Non-skid red or white full body Ceramic floor tiles of size 300 x 300 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as approved byEngineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and complete for finished item of work. (APSS No.701 & 707) |
| 6758 | 6.25.15.1 GROUND FLOOR |
| 6759 | 6.25.15.2 First floor |
| 6760 | 6.25.16 Providing skirting to internal wallswith vitrified tiles 7.30 mm thick length equal to flooring stones, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete including seigniorage charges, etc., complete for finished item of work, but excluding the cost of conveyance of all materials |
| 6761 | 6.25.17 Providing dadooing to walls with ceramic wall tiles 300x300 mm , set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete including seigniorage charges, etc., complete for finished item of work, but excluding the cost of conveyance of all materials |
| 6762 | 6.25.18 Providing and fixing factory made uPVC-anycolourcasement/Casementcum fixedglazeddoorcomprisingofuPVC multi-chamberedframe,sashand mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section madefromrollformingprocessof required length (shape & size according to Upvc profile),uPVC extruded glazing beads of appropriate dimension, EPDMgasket/ TPV,zinc alloy (white powdercoated) 3Dhingesandone handle oneach side ofpanelsalongwithzincplatedmild steel multi point lockinghavingtransmission gear, cylinder with keeps and one side key, G.Ifasteners100x8mmsizeforfixing frame to finished wall and necessarystainlesssteel screws, etc. Profile of frame & sash shall be mitred cut andfusionwelded at all corners, mullion (if required) shall be also fusionweldedincluding drilling of holes for fixing hardware\"s and drainage ofwater etc.After fixing frame the gap between frame and adjacent finished wall shallbefilledwithweatherproofsilicon sealentoverbackerrodofrequired sizeand of approved quality, all complete as per approved drawing & directionof Engineer-in-Charge inclusiveofcostofSingle/double glass panes and silicon sealent .Note:For uPVCframe,sashand mullionextrudedprofilesminus 5%toleranceindimensioni.e.in depth&widthofprofile shallbe acceptable.Variationinprofile dimension in higher side shall be acceptedbut no extra payment on this account shall be made. |
| 6763 | 6.25.19 Providing and fixing factory made uPVC any colour casement/casementcum fixed glazed windows comprising of uPVC multi-chambered frame,sash and mullion (where ever required) extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVCprofile), uPVC extruded glazing beads of appropriate- Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixedventilatorwithS.Sfrictionhinges (350 x 19 x 1.9) madeof (big series)frame67x60mm,sash67x80mm &mullion67x80mmallhavingwall thicknessof2.3±0.2mmandsingle glazing bead/double glazing bead of appropriatedimension.(Areaofwindow above 3.00 sqm upto 5.00 sqm). |
| 6764 | 6.25.20 Supply and placing of the Design Mix Concrete M 25 grade with 20mm size graded machine crushed hard granite metal (coarse aggregate) including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site , sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., including all operational, incidental and labour charges such asmachine mixing, laying concrete, curing etc., complete but excluding cost of steel and its fabrication charges for finished item of work |
| 6765 | 6.25.20.1 For entrance gate - foundation |
| 6766 | 6.25.20.2 For entrance gate - pedestals |
| 6767 | 6.25.20.3 for entrance gate - columnsupto plinth level |
| 6768 | 6.25.20.4 columnsupto 1st floor |
| 6769 | 6.25.20.5 columns for lift head room |
| 6770 | 6.25.20.6columns upto II floor |
| 6771 | 6.25.20.7 new block |
| 6772 | 6.25.20.8 lintel beam |
| 6773 | 6.25.20.9 BEAMS-GF |
| 6774 | 6.25.20.7 BEAMS-FF |
| 6775 | 6.25.20.8 ROOF SLAB |
| 6776 | 6.25.20.9new block I floor |
| 6777 | 6.25.20.10new block II floor |
| 6778 | 6.25.20.11 waist slab |
| 6779 | 6.25.20.12 mid landing |
| 6780 | 6.25.21 Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors |
| 6781 | 6.25.22 Supply and fixing of PVC false ceiling on MS/GI made skeleton framework. The frame shall be 24 X 48mm MS tube section fixed along with the wall. The entire frame work shall be concealedwith PVC section having overall dimensions of 6 X 250mm with a wall thickness of 1mm ± 0.3mm with tongue and groove system, provided with necessary arrangements for electrical connections, complete, for finished item of work. |
| 6782 | 6.25.23 RCC Sun shades 0.60m wide ,0.10m thick at fixed end and 0.05m at free endunit 1.00 RmtGF upto 3.66m heightcement content 400 kgs/cum M30 design mix |
| 6783 | 6.25.24 Supply of precast concrete blocks for paving of M-30 grade and thickness not less than 50 mm for Non-traffic areas conforming to IS 15658:2006 in allshapes and designs as per themanufacturer’sspecification |
| 6784 | ELECTRICAL ITEMS |
| 6785 | 6.25.25 Supply and Transportation of 40W LED Post top lantern made with cast Aluminum with decorative opal polycarbonate diffuser with IP 65 protection etc., complete with all accessories with not less than two years warranty.Makes: As per list of recommended brands. |
| 6786 | 6.25.26 Supply and transportation of LED Street light Luminaire made of pressurediecastaluminumbodywithpowdercoated,havingprotective toughenedglass/temperatureprotectivepolycarbonatediffuser,supply input voltage120 - 270V AC, P.F > 0.90, high power LEDs having System Efficacy >=120 lumens/watt and junction temperature < 70°C, with Ingress protection IP66, Luminaire performance complies to IS 10322 (Part 5/Sec- 3), driver surge protection 4KV, in-house additional Surge protection 10 KV with optics distribution, THD<10% at 110 Volts AC, driver efficiency >90%, CCT:3000K-5700K,minimumCRI>70,etc.,completewithearth connection and not less than two years warranty. |
| 6787 | 6.25.26.1 - 20 W |
| 6788 | 6.25.26.2 - 30 W |
| 6789 | 6.25.27 Supply of INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz,1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser.1.5 TR, 5 star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R- 410A, COP not less than 4.5. Makes: As per list of recommended brands as category I. |
| 6790 | 6.25.28 Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with Hinged door opening arrangement, including the supply of suitable boards with bakelite sheetas per IS specification suitable to withstand the wind speed of 180 KMPH for 9 Mtrs height Pole having dimensions Bottom 155 mm,. Top 70mm with 3mm thick, base plate 260 x 260 x 16mm and 4 Nos of M24 x 750 long \"J\" bolts along with template.Makes: As per list of recommended brands. |
| 6791 | 6.25.29 PROVIDING OF INDEPENDENT CHEMICAL EARTHING AFTER EXCAVATING AN EARTH PIT. THE EARTH ELECTRODES, 50MM DIA, WALL THICKNESS, 3.25MM, 3 MTR LONG COPPER BONDED (250 MICRONS) MS PIPE, STRIP IN PIPE SYSTEM FITTED WITH 40X6X3100MM COPPER BONDED STRIP FROM TOP TO BOTTOM, TERMINAL HOLE OF 12MM, PIPE FILLED WITH CONDUCTIVE CRYSTALLINE COMPOUND, INCLUDING 2 BAG OF EARTH LIFE COMPOUND (25 KGS EACH) AS PER IS 3043. withearth inspection chamber of dimensions: Width: 320 mm x 320 mm, Height: 192 mm, Weight: 30Kgs, Load bearing capacity: 5000 Kgs including drilling of bore in any kind of soil. |
| 6792 | 6.25.30 Supply, laying ,testing and commissioning of 4-pair, Cat6 Solid (Third party ETL Intertek tested up to 600 MHZ ) to support 1Gbps with Cross (+) filler pair separator & PVC sheath 23 AWG, STP/UTP Cable , Meets or exceeds ANSI/TIA-568-C.2 and UL Listed &RoHS Compliant in the existing raceways /PVC conduits including making connections to information outlets and patch panels with ferruling at both ends for identification with necessary tools for punching stripping crimping and testing required etc., complete.Makes: As per list of recommended brands as Category I. |
| 6793 | 6.25.30.1 - 6 UTP CABLE |
| 6794 | 6.25.30.2 - 6 STP CABLE |
| 6795 | 6.25.31.Supply and Fixing of Projector for front end Audience, As 4200lm, 5000:1contast ratio, 1080p@50/60Hz and HDMI & VGA interface etc. complete.Makes: As per list of recommended brands. |
| 6796 | 6.25.32 Supply and installation testing and commissioning of Tabletop mounted gooseneck type Conference Delegate unit Loudspeaker volume is set centrally at the Control Unit for all delegate units. To prevent acoustic feedback, the built-in loudspeaker is automatically muted when the microphone is on, the headphone volume level can be adjusted by means of a thumbwheel on the unit for maximum comfort, Nominal Acoustic Input 85dB SPL, Frequency Response 400Hz to 10kHz, Length of the microphone from the base of the stem 488mm.Makes: As per list of recommended brands. |
| 6797 | 6.25.33 Supply, Fixing and Installation of Tabletop/Podium mounted gooseneck type Conference Chairman unit Loudspeaker volume is set centrally at the Control Unit for all delegate units. To prevent acoustic feedback, the built-in loudspeaker is automatically muted when the microphone is on, the headphone volume level can be adjusted by means of a thumbwheel on the unit for maximum comfort.Makes: As per list of recommended brands. |
| 6798 | 6.25.34 Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary workall labour chages |
| 6799 | 6.25.35 Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages |
| 6800 | 6.25.36 Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complete for light, bell , fan and exhaust fan points in non - residential building |
| 6801 | 6.25.37 supply andrun of 2 of36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mainsincluding all labour charges |
| 6802 | 6.25.38 supply andrun of 1 of14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc. |
| 6803 | 6.25.39 supply andrun of2of6 sq.mm (7/18)WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc., |
| 6804 | 6.25.40 Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete |
| 6805 | 6.25.41 Supply and fixing TPN Distribution board with IP-30 protection suitable for 3 phase ELCB / RCCB / FP Isolator as incomer and 10kA SP MCBs as outing going including internal connection and labour charges for surface / flush mounting etc., complete.BLD-ELEC-4.4.3 |
| 6806 | 6.25.42 Supply and fixing of 48\" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride |
| 6807 | 6.25.43 Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega |
| 6808 | 6.25.44 Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs. |
| 6809 | 6.25.45 Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connectionswith twin core wire etc., complete |
| 6810 | 6.25.46 Supply and fixing of 16A 3/2 pin flush type wall plug modular socket with shutter and 16A modular switche controll on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete. Makes of Switches : GM G Home /Anchor Penta Cherry / Gold Madel Olive / Million Zoom / Great White |
| 6811 | WATER SUPPLY ITEMS |
| 6812 | 6.25.47 Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks unit 1.00 litre |
| 6813 | 6.25.48 Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with \"P\" or \"S\" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mmunit each |
| 6814 | 6.25.49 Supplying & Fixing low down porcelain flushing tank 10 Lit Capacity Hindustan Sanitary ware/ parry/ Neycer with internal componentsunit each |
| 6815 | 6.25.50 Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each |
| 6816 | 6.25.51 Supplying & Fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with internal flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995unit each |
| 6817 | 6.25.52 Supplying, laying, jointing and testing 110 mm dia 3 msingle Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand. unit each |
| 6818 | 6.25.53 Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand) unit each |
| 6819 | 6.25.54 Supply of 110 mm dia - Single Tee with Door - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)unit each |
| 6820 | 6.25.55 Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand unit each |
| 6821 | 6.25.56 Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice unit 1.00 Rmt |
| 6822 | 6.25.57 Constructing 457.2 mm x 457.2 mm (1\"6\"x1\"6\") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3\"0\") and fitted with light weight 457.2 mm x 457.2 mm (1\"6\"x1\"6\") C.I frame and cover of 20 Kg. unit each |
| 6823 | 6.25.58 S& F 25 mm Nominal Bore GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete unit 1.00 Rmt |
| 6824 | 6.25.59 S& F 20 mm Nominal Bore GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete unit 1.00 Rmt |
| 6825 | 6.25.60 S& F 15 mm Nominal Bore GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete unit 1.00 Rmt |
| 6826 | 6.25.61 S & F Gunmetal (GM) Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size unit each |
| 6827 | 6.25.62 S & F Gunmetal (GM) Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size unit each |
| 6828 | 6.25.63 S & F Gunmetal (GM) Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size unit each |
| 6829 | 6.25.64 S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent unit each |
| 6830 | 6.25.65 S& F GI union Ist Qualityunit each |
| 6831 | 6.25.65.1 - 12.70mm BMW-F-01 |
| 6832 | 6.25.65.2 - 19.05mm BMW-F-02 |
| 6833 | 6.25.65.3 - 25.40mm BMW-F-03 |
| 6834 | 6.25.66 Flush door shutters, solid bond woodblock board type with teak veneer on one face and commercial ply on another face (lipping): 30 mmthick conforming to IS:2202 |
| 6835 | 6.25.67 Providing and fixing of top hungVentilators made of pre-painted steel (Base steel as per IS 513 of 0.80 mm thick galvanized as per IS 277 with Zinc of 120 GSM), finish painted with a polyester paint of 60-65 microns thick and section for outer frame of 80 x 45 mm, centre mullion of 80 x 60 mm, section for shutter of 52 x 25 mm x 0.6 mm thick, outer frame and mullions to have rebate for glazed shutter with a provision for guard bars/grills and the sections cut to length metre joined with corner bracket, centre mullion fixed with mullion cap, 1 No. of High grade nylon latch handle, window stopper, 2 nos. of with MS Powder coated /SS ball bearing butt Hinges provided per shutter and windows fitted with 4 mm thick plain float glass with rubber gaskets including fixing the frames in concrete/masonry wall by means of self expanding screws, Including 10 mm Square guard bars with 6” (152.4mm) pitch etc., complete for finished item of work.Double openable ventilator shutter Size of 4’ 0” x 2’ 0” (1219.2mm x 609.6mm) outer frame section size of 80 x 45mm,shutter frame section size of 52 x 25mm, vertical mullion section size of 80 x 60 mm |
| 6836 | 6.25.68 Supply of the Followings plywood / laminates |
| 6837 | 6.25.68.1 - Pre laminated cement bonded particle board- 12 mm thick |
| 6838 | 6.25.68.2 - Pre laminated cement bonded particle board- 16 mm thick |
| 6839 | 6.25.68.3 - 9 Ply - 15 mm thick Plywood(IS:303) MR Grade |
| 6840 | 6.25.68.4 - 9 Ply - 18 mm thick Plywood(IS:303) MR Grade |
| 6841 | 6.25.68.5 - 9 Ply - 12 mm thick Both sides Teak Veneer Decorated Plywood (IS:1328) |
| 6842 | 6.25.68.6 - Laminate Sheets - Mat Finish: 1 mm thick |
| 6843 | 6.25.68.7 - Laminate Sheets - Mat Finish: 1.50 mm thick |
| 6844 | 6.25.68.8 - Laminate Sheets - Mat Finish: 1.80 mm thick |
| 6845 | 6.25.68.9 - Teak Veneer Lamination - 4 mm thick - Pencil Grains |
| 6846 | 6.25.68.10 - Teak Veneer Lamination - 4 mm thick - Natural Grains |
| 6847 | 6.25.69 Labour charges for making, fabricating office furniture, racks, work-station furniture, cup-board shutters with plywood/ MDF sheets, decolam/ veneer laminations including fixing cutting, making, assembling, fixing hinges, fixing fixtures, fixing locks, pasting sheets/ laminations fixing in position with necessary screws excluding cost of materials, accessories, fittings |
| 6848 | 6.25.70 Supply and fixing of 120\" Motorized projection screen with remote control etc. complete. |
| 6849 | 6.25.71 Supply and Fixing of Celling Mount Kits for front LED etc. complete |
| 6850 | 6.25.72 Supply and fabrication of MS framed structure like Window Grills, Compound Wall Grills, Iron Doors, Windows, Gates, MS Frame forchainlink mesh works,Roof Trusses by using square / rectangular MSsection as per IS 4923 including cost of welding rods, power charges, labour charges for cutting, placing, welding and erecting in position and fixing, cost & convenience of all materials including wastage to site with all taxes and duties etc complete for finished item of work. |
| 6851 | 6.25.73 Drilling of Bore well with DTH Rig per RM -Drilling of Bore well by down the hole hammer drilling to a finished dia of 165 mm dia in all formations suitable for down the hole hammer drilling such as medium hard rock formation to hard rock formation, all consolidated formation etc. and drilling in over burden to dia not less than 200 mm etc and reaming the bore well to suit insertion of suitable casing pipe etc., including insertion of casing pipe with couplings, caps any other relevant materials upto required depth as directed by the department including transportation of drilling rigs and supporting vehicle and including bore development (Flushing of Bore Well at an average pressure of 150 PSI) conducting yield test, consumables charges, Crew charges required in fixation of pipe assembly completely done to the satisfaction of the department and including all labour charges but excluding all taxes, the cost of casing pipe, couplings, cap etc., The entire work should be carried out as per IS -2800 Part I & II 1979 and amended from time to time.Drilling of Bore well 165 mm dia. up to 90.00 m depth |
| 6852 | 6.25.74 Manufacture, Supply and Delivery of Unplasticised PVCs Pipes for potable water supplies conforming to IS : 4985/2000 (3rd revision) with bell ends (Socket) as per specification in light Grey/Natural Ivory Grey/ Any other Color (except White) inclusive of transportation to the sub-divisional stores anywhere in AP excluding all taxes. |
| 6853 | 6.25.74.1 - 180 mm Dia-6.00 Kg/CM2 |
| 6854 | 6.25.75 Labour charges for sloting of pipes including all labour charges etc complete for 165 mm dia borewells,pipe sloting charges. |
| 6855 | 6.25.76 Supply & Fixing of 165 mm dia PVC Bore Cap per 1No-Fixing of Borewell caps including all labour charges etc., |
| 6856 | 6.25.77 S & F Gunmetal Gate (GM peet) valve as per IS - 778 Class - I, Indian make heavy type - 32 mm NB Size |
| 6857 | 6.25.78 Supply,Delivery and fixing 32mm GI B-Class pipe-Rate as per SSR 2025-26 |
| 6858 | 6.25.79 Supply of 3 Core 6.00 Sqmm. Flat Copper cable of ISI for Submersible Motors confirming to IS:694:1990. |
| 6859 | 6.25.80 Supply of 3 Core 2.50 Sqmm. Flat Copper cable of ISI for Submersible Motors confirming to IS:694:1990. |
| 6860 | 6.25.81 Supply of 6.00 Sqmm WPTC (Weather Proof Twin Core) ISI Alluminium WireMakes: Gold Medal / Million / GM / Vimal / Finecab / Nakoda / Plaza/ Payal / Sudhakar/ Rajnigandha/ Airson/Orbit/ollvin/Beljin |
| 6861 | 6.25.82 Geological Survey Charges excluding taxes. |
| 6862 | 6.25.83 Supply of 6.00sqmm WPSC (Weather Proof Single Core) ISI Alluminium Wire. |
| 6863 | 6.25.84 Supply and Transportation of,5star rated 3.00HP 5-10 Stage submersible motor pumpset, confirming to IS 8034 and motor confirming to IS 9283 with waterproof winding, Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415V ± 10%, Three Phase 50 Hz AC supply etc complete for 6\" Bore well. Makes: As per list of recommended brands as category I. |
| 6864 | 6.25.85 Fabrication , transportation and supply of suitablesize panel board for single phase submersiblemotor 2 to 3HP consisting of relay, Contactor,starting and running capacitors, Voltmeter, Ammeter,indicator lamps, MCB , on/off switch including supplyand fixing of DOL starter of complete.,.Makes: As per list of recommended brands.ELEC-5.4.16 |
| 6865 | 6.25.86 S&F 12.7mm N.P bib tap Indian make 3heavy duty |
| 6866 | 6.25.87 Supply of …... 10KA C/D Curve ISI Mark.Makes: As per list of recommended brands as category I of 32 A MCB ( 2 Pole ) including Cost and Conveyance of materials and Transportation Charges Etc., MAT-03072 |
| 6867 | 6.25.88 Supply, Installation, Testing and Commissioning of Electric Traction Passenger Lift of Makes: As per list of recommended brands. with•Rated capacity :- 8 Passenger/544Kg•Floors :- G+1 floor (2Stops/2 Landings)•Travel :- 3 to 4.2 mtrs•Location of Lift Machine:- MRL• Rated speed :- 1.0/1.25mps VS• Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm highmade from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/frames• Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio- visual alarm, VAS in Telugu & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floorClear Carsize of......mm wide x mm deep x. mm high |
| 6868 | 6.25.89 Construction of 300 mm Drain |
| 6869 | CAP Bill No 6.26.Implementation & Monitering cost |
| 6870 | 6.26.1 Air Quality Monitoring (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 6871 | 6.26.2 Noiselevel(5 Monitoringstation)onceinamonthforthree seasonsduring the constructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 6872 | 6.26.3 Water Quality Monitoring surface / ground(5 Monitoring station)once in a month for three seasons during theconstructionperiod at intake well, Filtration Plant/WTP, ELSR\"s, Raw/Clear Pipe Line & Distribution network |
| 6873 | PART-II (CAPEX) |
| 6874 | CAP BILL N0. 6.27 supply, delivery, laying, jointing & testing of HDPE 6Kg/Cm2 pipe of dia varing form 110 mm to 400 mm diafor Distribution network in Zone-1A ,1B ,2A,2B 2C, 3 & 4 areas |
| 6875 | 6.27.1 Cutting open BT road surface as well as asphalt concrete including water bound macadamand stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 6876 | 6.27.2 Cutting open C.C. road surface including stacking of excavated materials for pipe line trench work. as directed by the departmental officers. |
| 6877 | 6.27.3 Cutting open water bound macadam road including soiling for pipe line trench work. as directed by the departmental officers. |
| 6878 | 6.27.4 RBR-FNDN-1- (i-B) - In ordinary soils, by Mechanical meansEarthworkexcavationin all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by mechanical means. |
| 6879 | 6.27.5 BLD-CSTN-2-5 - (13): Earth work excavation for foundations and depositing on bank for all lifts and with an initial lead of 10m including all operational, incidental, labour charges such as shoring ,sheeting, planking, strutting, etc. complete for finished item of work including seigniorage excluding dewatering charges etc as per SS - 20 B (APSS 308). Ordinary rock (not requiring blasting)-Manual Means-Upto 3 m depth |
| 6880 | 6.27.6 RBR-FNDN-1- (i-A) In ordinary soils, by Manual meansEarthwork excavation in all kinds of soil for Pipe line trenches as per drawings and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material , dressing of sides and bottom as per Technical Specification304 MORTH andas directed by the departmental officer includingprotecting the existing utility services wherever it is possibleduring the execution and taking all precautionary measures in the restricted areas for laying sewer/water lines including divertion of traffic andbackfilling in trenches with excavated suitable material anddisposal of remaining earthupto a lead of 50 m, including all incidental and operational charges etc., complete for Pipe Lines by manual means. |
| 6881 | 6.27.7 RBR-FNDN-1- (iv) - In hard rockblasting prohibited:Excavation in Hard rock (blasting prohibited) Upto 3 m depth including 1.5 m depth in hard rock : Earthwork excavation in hard rock such as sheet rock and boulders in habitant areas where conventional blasting can not be donefor pipe line trenches, including all incidental and operational charges etc., complete. |
| 6882 | 6.27.8 Manufacture, supply, delivery of HDPE pipes conforming to IS 4984 - 1995 includingtransportation to any where in TG, Excise duty, sales tax etc., complete ( Supply upto 90mm dia in coil & above 90mm dia strightin length in 6M) (6 Kg/Sq Cm) |
| 6883 | 110 mm dia HDPE 6Kg/Cm2 pipe |
| 6884 | 160 mm dia HDPE 6Kg/Cm2 pipe |
| 6885 | 200 mm dia HDPE 6Kg/Cm2 pipe |
| 6886 | 315 mm dia HDPE 6Kg/Cm2 pipe |
| 6887 | 6.27.9 Lowering, laying, jointing & testing of HDPE Pipe line laid to true alignment and gradiant tohydraulic field test pressure per IS codeincluding cost of water with minimum water lead of 500m (Labour charges only)Outer dia of pipes in mm. |
| 6888 | 110 mm dia HDPE 6Kg/Cm2 pipe |
| 6889 | 160 mm dia HDPE 6Kg/Cm2 pipe |
| 6890 | 200 mm dia HDPE 6Kg/Cm2 pipe |
| 6891 | 250 mm dia HDPE 6Kg/Cm2 pipe |
| 6892 | 315 mm dia HDPE 6Kg/Cm2 pipe |
| 6893 | 6.27.10 Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to any where in AP, excluding Central excise duty, sale taxetc., complete |
| 6894 | Bends for |
| 6895 | 110 mm dia HDPE 6Kg/Cm2 pipe |
| 6896 | 160 mm dia HDPE 6Kg/Cm2 pipe |
| 6897 | 200 mm dia HDPE 6Kg/Cm2 pipe |
| 6898 | 250 mm dia HDPE 6Kg/Cm2 pipe |
| 6899 | 315 mm dia HDPE 6Kg/Cm2 pipe |
| 6900 | End caps for |
| 6901 | 110 mm dia HDPE 6Kg/Cm2 pipe |
| 6902 | 160 mm dia HDPE 6Kg/Cm2 pipe |
| 6903 | 200 mm dia HDPE 6Kg/Cm2 pipe |
| 6904 | 250 mm dia HDPE 6Kg/Cm2 pipe |
| 6905 | 315 mm dia HDPE 6Kg/Cm2 pipe |
| 6906 | Long neck pipe ends for |
| 6907 | 110 mm dia HDPE 6Kg/Cm2 pipe |
| 6908 | 160 mm dia HDPE 6Kg/Cm2 pipe |
| 6909 | 200 mm dia HDPE 6Kg/Cm2 pipe |
| 6910 | 250 mm dia HDPE 6Kg/Cm2 pipe |
| 6911 | 315 mm dia HDPE 6Kg/Cm2 pipe |
| 6912 | MS flanges to suit HDPE pipes for |
| 6913 | 110 mm dia HDPE 6Kg/Cm2 pipe |
| 6914 | 160 mm dia HDPE 6Kg/Cm2 pipe |
| 6915 | 180 mm dia HDPE 6Kg/Cm2 pipe |
| 6916 | 200 mm dia HDPE 6Kg/Cm2 pipe |
| 6917 | 225 mm dia HDPE 6Kg/Cm2 pipe |
| 6918 | 250 mm dia HDPE 6Kg/Cm2 pipe |
| 6919 | 280 mm dia HDPE 6Kg/Cm2 pipe |
| 6920 | 315 mm dia HDPE 6Kg/Cm2 pipe |
| 6921 | 355 mm dia HDPE 6Kg/Cm2 pipe |
| 6922 | 400 mm dia HDPE 6Kg/Cm2 pipe |
| 6923 | Tees for |
| 6924 | 110 mm dia HDPE 6Kg/Cm2 pipe |
| 6925 | 160 mm dia HDPE 6Kg/Cm2 pipe |
| 6926 | 200 mm dia HDPE 6Kg/Cm2 pipe |
| 6927 | 250 mm dia HDPE 6Kg/Cm2 pipe |
| 6928 | 315 mm dia HDPE 6Kg/Cm2 pipe |
| 6929 | 6.27.11 Centrifugally cast (spun) Ductile Iron pressure pipes for water, Gas and sewage with socket spigot ends confirming to I.S.: 8329/2000 in standard working lengths of 4,5,5.5 & 6 meterfor classification K7suitable for push on joint ( Rubber Gasket D jointing) with cement mortar lining inside the pipes with out side Zinc coating. Rates areincluding Transportationand CED and ST etc,. complete. |
| 6930 | 350mm |
| 6931 | 300mm |
| 6932 | 6.27.12 PHE-LCIS-1: Lowering C.I. / D.I.Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994) |
| 6933 | 350mm |
| 6934 | 300mm |
| 6935 | 6.27.13 PHE-JCIR-4: Jointing the C.I. Pipes, D.I. Pipes & fittings with Rubber Gasket includingcost of the gasket, all sundries filling with water with a water lead upto 500 m and testing to required pressure etc., complete as per BIS No.3114/85. |
| 6936 | 350mm |
| 6937 | 300mm |
| 6938 | 6.27.14 Manufacture, supply and delivery of centrifugally cast (spun ) ductile iron fittings conforming to IS No. 9523/2000 having dimentions as per table. , zinc coated externally with inside mortor lining (with finishing as per class 13/IS 9523/2000 as per Code No 1 ) including transportation, taxes and duties etc. |
| 6939 | upto 500mm Dia Flanged sockets , flanged spigots & double socket bends |
| 6940 | 6.27.15 Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per IS:1538. |
| 6941 | DI. D/F Sluice valves ofPN.16 class |
| 6942 | 100mm dia Sluice Valves |
| 6943 | 150mm dia Sluice Valves |
| 6944 | 200mm dia Sluice Valves |
| 6945 | 250mm dia Sluice Valves |
| 6946 | 300mm dia Sluice Valves |
| 6947 | 350mm dia Sluice Valves |
| 6948 | 400mm dia Sluice Valves |
| 6949 | 100mm dia Scour valves |
| 6950 | 6.27.16 PHE-CISV-15 : Lowering, keeping in position and fixingD.I. sluice valves (with cap / with hand wheel & reflex valves)includingcost of bolts, nuts, rubber insertion, sluice valve and tail pieces |
| 6951 | 100mm dia Sluice Valves |
| 6952 | 150mm dia Sluice Valves |
| 6953 | 200mm dia Sluice Valves |
| 6954 | 250mm dia Sluice Valves |
| 6955 | 300mm dia Sluice Valves |
| 6956 | 350mm dia Sluice Valves |
| 6957 | 400mm dia Sluice Valves |
| 6958 | 6.27.17 Manufacture, Supply and Delivery of CI/DI Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 6959 | 100mm Dia |
| 6960 | 150mm Dia |
| 6961 | 200mm Dia |
| 6962 | 250mm Dia |
| 6963 | 300mm dia |
| 6964 | 6.27.18 Manufacture, Supply and Delivery of MS Dismantling joints with both side flange end siutable for installations in between flange end pipes including all taxes etc., Complete. |
| 6965 | 350mm dia |
| 6966 | 400mm Dia |
| 6967 | 6.27.19 PHE-JCIF-5-: Jointing CI pipes, fittings and valves with flanged ends including cost of jointingmaterials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.) |
| 6968 | 100mm dia Sluice Valves |
| 6969 | 150mm dia Sluice Valves |
| 6970 | 200mm dia Sluice Valves |
| 6971 | 250mm dia Sluice Valves |
| 6972 | 300mm dia Sluice Valves |
| 6973 | 350mm dia Sluice Valves |
| 6974 | 400mm dia Sluice Valves |
| 6975 | 6.27.20 anufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12orequivalent gradeasperI.S.3896-part2-1985 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality.SEpoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. |
| 6976 | 50mm |
| 6977 | 80mm |
| 6978 | 6.27.21 Labour charges for fixing Kinetic Air ValvesDouble Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. |
| 6979 | 50mm |
| 6980 | 80mm |
| 6981 | 6.27.22 Supply and fixing of precast RCCchambers having the size of 910mm at bottom and 530mm at top with tapers along with FRC cover and frame, laying in CC (1:2:4) prop including cost of material, labour charges, curing, conveyance etc., complete as per standard specifications and standard drawings.. |
| 6982 | For up to 200mm dia Sluicevalves and forrevamping pipe lines |
| 6983 | 6.27.23 Construction ofValvechamberswithCement Concrete vertical walls and RCCslab fitted withFRC man hole cover and frame, etcincluding cost and conveyance of all material, labour charges, curing etc., complete as per standard specifications and standard drawings.. |
| 6984 | for 250mmdia to 350 Sluice valves |
| 6985 | for 400mmdia to 600 Sluice valves |
| 6986 | 6.27.24 Carting away thesurplus excavatedmaterial i.e.Earthand Rubble from the site to a suitabledistanceof about 10.00 Kmincluding loading, unloading , conveyance charges and dumping the carted material at the contractors cost, labour charges, all leads & lifts and other incidental and operational charges etc., complete. |
| 6987 | 90% of rock Qty |
| 6988 | 6.27.25 Supply and filling with crusher dust complying with standard specifications with all leads and lifts in layers consolidating with watering and ramming including cost and conveyance of all materials and labour charges, all taxes, seignorage charges, conveyance of sand including loading, unloading etc., complete as per SS and as directed by the departmental officer in charge of the work for filling the foundation and the basement |
| 6989 | 6.27.26 Vibrated cement concrete M30 using graded HBG metal including cost and conveyance of all materials land labour charges for centering, machine mixing, laying, vibrating and curing etc., including all other incidental charges of all T&P etc., for finished item of work as per MORTH specifications 1500,1700, 2100 and 2702 and as directed by the departmental engineers in charge. |
| 6990 | 6.27.27 Manufacture, supply and delivery of DuctileIron pipes and fittings (spls.) conforming to IS. No. 7181/1986, 5531/1988, 3950/1979 and CID. joints confirming to IS No.8794/1988 at site of work anywhere in A.P.including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. |
| 6991 | 6.28 Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100Pipe including lowering, laying and jointing including earth work excavation and refilling the pipe line trench after layingthe pipe lineand including cost of 15mm dia meter of BIS standard and construction of meterchamberetc complete and transfering of house service connection as directed by departmental officer for finished item of work. |
| 6992 | Providing house service connections at house holds side in earthern roads |
| 6993 | Providing house service connections at other side in earthern roads |
| 6994 | Providing house service connections at otherside in BT &CCroads |
| 6995 | Providing house service connections at HHside in BT &CCroads |
| 6996 | OPEX |
| 6997 | OPEX.6.29 Operation and Maintenance for the Seven (7) Yearsincluding Defect Liability Period-From Source to ELSR\"s in Yelamanchili NP |
| 6998 | FOR 7YEARs |
| 6999 | A) PERSONAL |
| 7000 | Personal required for operating cum Pumphouses |
| 7001 | Pump Operator (1x3) |
| 7002 | Helper (1x3) |
| 7003 | Watch man (1x1) |
| 7004 | Personal required for ELSR sites/ Gravity Mains/ Pumping Mains |
| 7005 | Helpers for Pumping Mains (2) |
| 7006 | Watchman- Reservoirs (13x1) |
| 7007 | Helper- GravityMain (2) |
| 7008 | Consumables for 7 years |
| 7009 | suply and delivery as per IS standards Chlorine gas for disinfection as per CPHEEO manualChlorine gas ( 3 mg/lit) for disinfection |
| 7010 | Alum at 15mg/lt |
| 7011 | Repairs to pumpsets & Water pipe lines ( for Fiveyears ) |
| 7012 | i) Replacement of bearings of pumpsets |
| 7013 | ii) Replacement of sleeves |
| 7014 | Clear Water Motors |
| 7015 | iv)Replacement of glands of sluice valves |
| 7016 | v) Replacements of balls of Air valves |
| 7017 | vi) Greease |
| 7018 | vii) Gland Packing |
| 7019 | 6.30 Implementation of EMP |
| 7020 | Monitoring Costs : Operation Phase (7 years) |
| 7021 | 6.30.1 Air quality monitoring (5 monitoring station) once in a month for 3 seasons during the construction period at intake well, filteration plant/WTP,ELSR,RAW/clear Pipeline and disturbution network |
| 7022 | 6.30.2 Noise level (5 monitoring station)once in a month for 3 seasons during the construction period at intake well, filteration plant/WTP,ELSR,RAW/clear Pipeline and disturbution network |
| 7023 | 6.30.3 Water quality monitoring surface/ground (5 monitoring station) once in a month for 3 seasons during the construction period at intake well, filteration plant/WTP,ELSR,RAW/clear Pipeline and disturbution network |
| 7024 | 6.30.4 Compensatory plantation andthree years maintenance (Compensatory afforestation ratio is 1:5) |
| 7025 | 6.30.5 Sprinkling of wateronce in a day fortwo years (excluding rainy days):500 days @ Rs.1000/trip |
| 7026 | OPEX. 6.31 OPERATION & MAINTENANCE COST Local SCADA at ULB |
| 7027 | 6.31.1 To asist to attend the service calls by the seniour service engineerJr. Service Engineer(Diploma Engineer)Rate as per Labour Rates LAB-00127 of CSSR 2025-26 |
| 7028 | 6.31.2 With assistance of the DBA, preparation of daily reports, monthly billing, correspondence with consumers and also co-ordinate with the GVMC Officials for obtaining of required information when ever asks.Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-26 |
| 7029 | 6.31.3 To assist the entire team, dispatches and also maintain SCADA station clean and neat Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 |
| 7030 | 6.31.4 To attend service calls and break down on 24 x 7Hiring of vehicle (4 wheeler)Rate as per G.O.MS.No.87Dated 01-06-2017. |
| 7031 | II) MAINTAINANCE OF LOCAL CONTROL STATION : |
| 7032 | 6.31.5Replacement of necessary servicable materials(Reagents) for Chlorine Analysers*Each Reagent bottle willwork for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. |
| 7033 | 6.31.6Replacement of necessary tranducers for PH analysers |
| 7034 | 6.31.7Replacement of necessary tranducers for Turbidity analysers |
| 7035 | 6.31.8 GPRS Connections, WTP Quality Management,ELSR Management,DMA Management |
| 7036 | 6.31.9 BSNL Charges for static IP |
| 7037 | 6.31.10 Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
| 7038 | 6.32 OPERATION & MAINTENANCE COSTCentral SCADA for ULB |
| 7039 | I) ESTABLISHMENT : |
| 7040 | 6.32.1 Application Engineer (Graduate Engineer)Rate as per Labour Rates LAB-00130 ofCSSR 2025-26 |
| 7041 | 6.32.2 System Engineer (Graduate Engineer)Rate as per Labour RatesLAB-00130 ofCSSR 2025-26 |
| 7042 | 6.32.3 Data OperatorRate as per Labour Rates LAB-00134 ofCSSR 2025-262 shifts |
| 7043 | 6.32.4 Office assistantRate as per Labour Rates LAB-00124 ofCSSR 2025-26 2 shifts |
| 7044 | II) MAINTAINANCE OF LOCAL CONTROL STATION : |
| 7045 | 6.32.5 BSNL Charges for static IP |
| 7046 | 6.32.6 Data base management for WEB reporting |
| 7047 | 6.32.7 Charges for maintainance of PC\"s,Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS,maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail