}

Supply Of Lcp Set For Variable Angle Anteromedial Distal Tibial 2.7/3.5 Mm System, Lcp Set For Variable Angle Posterolateral Distal Tibial Plate 2.7Mm System, Lcp Set For Clavicle Shaft Fracture, Lcp Set For Clavicle Fracture With Extension & Lcp-Tit, trivandrum-Kerala

Southern Railway has published Supply Of Lcp Set For Variable Angle Anteromedial Distal Tibial 2.7/3.5 Mm System, Lcp Set For Variable Angle Posterolateral Distal Tibial Plate 2.7Mm System, Lcp Set For Clavicle Shaft Fracture, Lcp Set For Clavicle Fracture With Extension & Lcp-Tit. Submission Date for this Tender is 21-10-2025. Orthopedic equipment Tenders in trivandrum Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

51231990
Supply Of Lcp Set For Variable Angle Anteromedial Distal Tibial 2.7/3.5 Mm System, Lcp Set For Variable Angle Posterolateral Distal Tibial Plate 2.7Mm System, Lcp Set For Clavicle Shaft Fracture, Lcp Set For Clavicle Fracture With Extension & Lcp-Tit
Tender
Indian
Kerala
Trivandrum
21-10-2025
BootCamp

Tender Details

Supply Of Lcp Set For Variable Angle Anteromedial Distal Tibial 2.7/3.5 Mm System, Lcp Set For Variable Angle Posterolateral Distal Tibial Plate 2.7Mm System, Lcp Set For Clavicle Shaft Fracture, Lcp Set For Clavicle Fracture With Extension & Lcp-Titanium Broad 4.5Mm Plate-6 To 9 Holeslcp Set For Variable Angle Anteromedial Distal Tibial 2.7/3.5 Mm System, Lcp Set For Variable Angle Posterolateral Distal Tibial Plate 2.7Mm System, Lcp Set For Clavicle Shaft Fracture, Lcp Set For Clavicle Fracture With Extension & Lcp-Titanium Broad 4.5Mm Plate-6 To 9 Holes,Srphc401501-Lcp Set For Clavicle Fracture With Extension - Consisting Of One Precontoured Variable Angle Locking Plate With Extension 2.7 Mm Profile.Each Set Should Consist 1 Plate 6 Nos Of 2.7 Mm Variable Angle Locking Scre Ws And 4 Nos Of 2.7 Mm Cortex Screw With Appropriate Sizes Of 467 Holes And Sides (Left Or Right) Of Plates For The Corr Ect Side .The Plate Should Have Suture Holes In The Head Portion And Bending Notch In The Shaft . Each Set Along With C Omplete Set Of Instrumentation Including Variable Angle Sleeves And Torque Limiting Screw Driver. It Must Be Supplied A S And When Required Basis. The Screw System Merges Locking Screw Technology With Conventional Plating Technology And Should Be Mri Compatible. Unit:Set [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Max 8 Lacs ] ] Achd/Surg.Store/Rh/Per, Sr Tamil Nadu 5.00 Set , Srphc401231-Lcp Set For Variable Angle Anteromedial Distal Tibial 2.7/3.5 Mm System - Consisting Of One Lcp P Late 2.7 Mm Variable Angle Six Locking Screws And 3.5 Mm Four Cortical Screws. The Set Must Be Supplied As And When Re Quired Basis Consisting Of 4 To 10 Holes With Appropriate Sizes And Sides (Left Or Right) Of Plates For The Correct Side A Nd Appropriate Screws Of 2.7/3.5Mm Diameter As And When Required. Each Set Along With Complete Set Of Instrumentatio N Including Variable Angle Sleeves And Torque Limiting Screw Driver. Should Be Mri Compatible. It Must Be Supplied As An D When Required Basis. The Screw System Merges Locking Screw Technology With Conventional Plating Technology And Should Be Mri Compatible. Unit:No [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Max 8 Lacs ] ] , Srphc401232-Lcp Set For Variable Angle Posterolateral Distal Tibial Plate 2.7Mm System - Consisting Of One L Cp Plate 2.7 Mm Variable Angle Four Locking Screws And 2.7 Mm Two Cortical Screws The Set Must Be Supplied As And Wh En Required Basis Consisting Of 4 To 6 Holes With Appropriate Sizes And Sides (Left Or Right) Of Plates For The Correct Si De And Appropriate Screws Of 2.7Mm Diameter As And When Required. Each Set Along With Complete Set Of Instrumentati On Including Variable Angle Sleeves And Torque Limiting Screw Driver. It Must Be Supplied As And When Required Basis. T He Screw System Merges Locking Screw Technology With Conventional Plating Technology And Should Be Mri Compatibl E. Unit:No [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Max 8 Lacs ] ] , Srphc401542-Lcp-Titanium Broad 4.5Mm Plate-6 To 9 Holes.The Screw System Merges Locking Screw Technolog Y With Conventional Plating Technology. The Set Must Be Supplied With 20 Cortical Screws And 40 Locking Screws Along With Complete Set Of Instrumentation Including Sleeves And Torque Limiting Screw Driver. It Must Be Supplied As And Wh En Required Basis. Unit:Set [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Max 8 Lacs ] ] , Srphc401502-Lcp Set For Clavicle Shaft Fracture - Consisting Of One Precontoured Variable Angle Locking P Late With Complete 2.7 Mm Profile.Each Set Should Consist 1 Plate 4 Nos Of 2.7 Mm Variable Angle Locking Screws And 4 N Os Of 2.7 Mm Cortex Screw With Appropriate Sizes Of 121314 Holes And Sides (Left Or Right) Of Plates For The Correct Sid E. Each Set Along With Complete Set Of Instrumentation Including Variable Angle Sleeves And Torque Limiting Screw Driv Er. It Must Be Supplied As And When Required Basis. The Screw System Merges Locking Screw Technology With Conventional Plating Technology And Should Be Mri Compatible. Unit:Set [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitted: Max 8 Lacs ] ] Achd/Surg.Store/Rh/Per, Sr Tamil Nadu 15.00 Set

Key Value

Document Fees
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail