Tender For Repair White Washing In Judicial Officer S Residence No. K.J. -01 At Outlying Court Khurja - Demolishing cement concrete manually/ by mechanical means includingdisposal of material within 50 metres lead as per direction of Engineer - in - charge,Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) (DSR-15.2.2) 2 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) (DSR-22.14.1 ) 3 Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand) (DSR-22.14.3 ) 4 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge, With cement mortar 1:4 (1cement: 4 coarse sand) (DSR-14.1.2 ) 5 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (DSR-12.22) 6 Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, including preparation of surface but excluding grading complete withBitumen felt (hessian base) type 3 grade I conforming to IS : 1322 (DSR-22.8.1) 7 Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 (DSR-12.19.1 ) 8 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard designIn 75x75 mm deep chase (DSR-12.21.1) 9 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting,unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead for all leads including all lifts involved. (DSR-15.60) , 10 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(DSR 2023- 15.56) 11 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR-11.37A) 12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below (DSR-15.12.1) 13 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres (DSR 15.12.2) 14 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below (DSR 15.13.1) 15 Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size). (DSR-9.53) 16 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) Sal wood (DSR-9.1.2 ) 17 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) Kiln seasoned and chemically treated hollock wood (DSR-9.1.3) 18 Providing and fixing glazed shutters 30 mm thick for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws Kiln seasoned and chemically treated hollock wood (DSR-9.9.2.2) . 19 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR-9.9.2) Kiln seasoned and chemically treated hollock wood 9.9.2.1 35 mm thick, (DSR-9.11.1) 5.0 mm thick (weight not less than 12.50 kg per sqm) instead of 4 mm thick (weight not less than 10 kg per sqm). 20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: (DSR-9.21.3), 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws, Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) sqm 2093.70 (DSR-9.23 9.22.1) On one side only, Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 21 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete 125x65x2.12 mm (DSR-9.55.1) 22 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete 100x58x1.90 mm (DSR-9.55.2 ) 23 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 300x10 mm (DSR-9.97.1) 24 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 100x10 mm (DSR-9.97.5 ) 25 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type (DSR-9.114.1 ) 26 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125 mm (DSR-9.100.1) 27 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 100 mm (DSR-9.100.2) 28 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 300x16 mm (DSR-9.96.1) 29 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With second class teakwood beading 62X19 mm (DSR-9.51.1) 30 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR-13.91) 31 Finishing walls with Acrylic Smooth exterior paint of required shade Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface: (DSR-13.111.1) 32 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work (DSR-13.99.1 ) 33 Wall painting with premium acrylic emulsion paint of one coat interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour (DSR-13.83.1 ) 34 Supply & fixing shade for ventilator, windows of any length or width, fibre reinforced translusent sheetor any other type as directed by Engr in charge, fixed over MS brackets , framed and welded as per site requirements all as directed by Engineer In charge, (MR.) 35 Labour & material for welding of existing old grills of compound wall Approx size 2.05x1.75 mtr, including scaffolding, genrator, electrods etc as directed by Engineer In charge (MR)