Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #51224103

Tender For Repair And Maint Of Lifts And Eot Cranes Of Various Capacities Installed At Technical Magazine Lc Area At Pxe And Itr Chandipur

Issued by Statutory Bodies & Commissions/Committees · chandipur, Odisha
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Oct 2025
0 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
chandipur → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repair And Maint Of Lifts And Eot Cranes Of Various Capacities Installed At Technical Magazine Lc Area At Pxe And Itr Chandipur

BOQ

Name of Work: REPAIR AND MAINT OF LIFTS AND EOT CRANES OF VARIOUS CAPACITIES INSTALLED AT TECHNICAL, MAGAZINE, LC AREA AT PXE & ITR CHANDIPUR
Sl. No. Item Description
1Servicing and maintenance of Goods cum passenger lifts in PXE technical(Total 03 nos of lift)of capacity one or twoTonne AC electric operated variable voltage variable frequency controlserving for G+8/G+2/G+3 floorsby replacing the trailing cable, checking of all power wiring termination, upper and lower limit switches for proper connection, Checking / adjusting guide clamp, Check all the locks functioning properly mechanically and electrically after opening the covers, check all sets of screws and spring and replace where necessary so that the lever should lock the brake properly for smooth operation of lift ,Repair/maintenance of all door shuttersof lift by repairing / replacing unserviceable parts, complete greasing andcarrying out door adjustment, guideclamp adjustment, locking system etc for smooth functioning complete and all as specified anddirected by Engineer-in-Charge.NOTE:- (a) Maintanace ofall03 lifts will be done on monthly basis/ 6 times duringperiod of contract (b) All switches, contactor, door shoe, door contact, door spring, SPP, Rectifier,door roller,door lock set, LOP & COP button, Relay , gear oil, consumable stores like cotton waste/cleaning materials, lubricants are deemed to be included inrate quoted however the spare parts other than aboveshall be measured & paid separately. (c) The rates includes monthly mainantance charge of all five lifts and including spare parts under 1(b). (d ) The visit & maintenance work shall be got executed through classic Enterprises/ Kone Elevator/OTISE Elevator and test report of each lift will be submitted to Engr-in-charge.
2Servicing and maintenance of Goods cum passenger lifts inITR area(Total 02 nos of lift)of capacity one or twoTonne AC electric operated variable voltage variable frequency controlserving for G+2/G+3 floorsby replacing the trailing cable, checking of all power wiring termination, upper and lower limit switches for proper connection, Checking / adjusting guide clamp, Check all the locks functioning properly mechanically and electrically after opening the covers, check all sets of screws and spring and replace where necessary so that the lever should lock the brake properly for smooth operation of lift ,Repair/maintenance of all door shuttersof lift by repairing / replacing unserviceable parts, complete greasing andcarrying out door adjustment, guideclamp adjustment, locking system etc for smooth functioning complete and all as specified anddirected by Engineer-in-Charge.NOTE:- (a) Maintanace ofall02 lifts will be done on monthly basis/ 6 times duringperiod of contract (b) All switches, contactor, door shoe, door contact, door spring, SPP, Rectifier,door roller,door lock set, LOP & COP button, Relay , gear oil, consumable stores like cotton waste/cleaning materials, lubricants are deemed to be included inrate quoted however the spare parts other than aboveshall be measured & paid separately. (c) The rates includes monthly mainantance charge of alllifts and including spare parts under 1(b). (d ) The visit & maintenance work shall be got executed through classic Enterprises/ Kone Elevator/OTISE Elevator and test report of each lift will be submitted to Engr-in-charge.
3Supply only Mother board for 1/2 tonn Lift complete all as specified.
4Supply only SS Landing door 1000X2100 opening all as specified.
5Supply onlyRL 9 PCB complete all as specified and directed.
6Supply only door senser complete all as specified and directed.
7Supply only Door drive with incoder complete all as specified and directed.
8Supply only LOP PCB complete all as specified and directed.
9Supply only COP PCB complete all as specified and directed.
10Supply only Door belt complete all as specified and directed.
11Supply only SMPS complete all as specified and directed.
12Supply and fixing in repair ARD (i.e. Automatic rescue device) complete set with Battery, reed switch, magnet etc ofcapacity 3000VAall as specified and directed.
13Repair of the thruster of 2 to 5 toncapacities of EOT crane with gear holding brakes / Hoist / Creep / Cross travel and long travel, rewinding the burnt outelectromagnetic thruster coil with super enamelled copper coil of existing gauge and varnishing, heating and testing etc. complete repairing of oil pump by replacing worn out parts, oil seal, O ring, bush and bearing - 02 nos. check nuts, lock pins all as requiredand directed by Engr in charge.
14All as per item No.13 above but for capacity of 10 TonEOT cranes all as requiredand directed
15Supply and filling of gear oil in gear box of lift andEOT crane including top up all as specified and directed .
16Supply and filling of transformer oilsuitable for electro hydraulic thruster break ofEOT crane including top up all as specified and directed.
17Supply and fix brake shoesin pair (02 Nos) on drum diameter 100 to 200 mm suitable for 2 to 5 ton cranewith necessary fittings complete including taking down old unserviceable one all as directed.
18Supply and fix brake shoesin pair (02 Nos) on drum diameter 100 to 200 mm suitable for 10ton cranewith necessary fittings complete including taking down old unserviceable one all as directed.
19Supply and fix brake liner for any capacity of EOT crane complete as specified.
20Supply and Fixballbearing ofas per existing size for 20 Ton capacity make and model for thruster of 2 to 10ton capacitycrane complete as specified and directed.(Make :TATA/SKF)
21All as per Item No. 20above but bearing of size for 15 Ton capacity suitableas per existing make and model for long travel (LT) complete as specified and directed.
22All as per Item No. 20 above but bearing of size suitableas per existing make and modelfor crosstravel (CT) complete as specified and directed
23Supply and fix flexible copper cable of size 4 sq mm, 4 core,1100 V including provision of movable clampsincluding taking down old unserviceable cableas specified and directed
24Supply and fix flexible copper cable of size 2.5 sq mm, 4 core,1100 V including provision of movable clampsincluding taking down old unserviceable cableas specified and directed
25S&F in repair 6 Sqmm, 4 Core TRS flexible Rubber cable , with copper conductors, 1100 Volts grade multi stranded & sheathedfor various capacity crane as specified and directed.Note:- wall portion of cable will be inside suitable size PVC pipe and fixed with clamp on wall.
26Supply and fix in repair rotary type limit switch with 40:1 ratiosuitable for 2 Tonne to 10 Tonne capacity EOT crane main hoist all as specified.
27Supply and fix in repair Levertype limit switch for CT/LT suitable for 2 Tonne to 10 Tonne capacity EOT crane main hoist all as specified.
28S&Fin repair bimetal overload relayof 16-25 Amps capacities for cranes of any capacity and as per site requirement all as specified .
29S&Fin repair bimetal overload relayof 25-32 Amps capacities for cranes of any capacity and as per site requirement all as specified .
30Supply and fixing in repairs On-delay timer switchwith NO+NC range of 0.05-60 Sec and coil voltage of 110 volt AC.(Make-\"BCH\" or equivalent model of L&T/Siemens).
31S&F in repairpower contactor of capacity 70 Amps, AC3, 415 volts main contactor coil voltage 110 Voltincluding taking down old one all as directed.Make – BCH/Hager/L&T
32All as per Item No 31 but for 40/32 Amp including taking down old one all as directed.
33All as per Item No 31 but for 16 Amp,including taking down one all as directed.
34All as per Item No 31 but for 9.1 Ampincluding taking down one including taking down old one all as directed.
35S&F MCB TPN 31 Amps rating 415 volts \"C\" Seriesincluding taking down old one all as directed.
36Supply and fix MCCB 4 Pole, current rating 100 Amp, breaking capacity 25kA at 415V,50Hz including connection and testing complete all as directed.
37M&L for spraypainting to completeEOT/HOTCranes of 2 to 10 ton capacity with a CT spanup to maximum of 18 Mtrs and a hook height maximum up to of 10mtrs with LT Span, completeincluding preparing the surfaces by all suitable means by removing the old paint with sand paper and spray painting the complete parts ofcrane withonecoat of approved synthetic enamel paint of superior quality over one coat of red oxide , and writing machine No with synthetic enamel paint different from crane body colour on the crane complete all as directed by Engineer-in-Charge.
38Supply and Fix Cable trolley for EOT cranes of capacity 3 to 10 Ton of any span length and any Height complete as specified.
39Supply and fix DSL track trolleyfor EOT crane of capacity 05-10 ton complete as specified.
40S&Fin repair exavacator push botton switch of capacitysuitable for 2 to 10 ton capacity EOT crane main hoist .
41S&Fin repair indicator lampsuitable 110 volts coils of any make suitable for 2 to 10 ton capacity EOT crane as specified.
42S&F in repair thermal overload relay of RR 3.8 to 6.0 A Make: BCH/L&T/Legrand
43S&F in repair thermal overload relay ofRR 6.0 to 9.3 A Make: BCH/L&T/Legrand
44S&F in repair thermal overload relay of RR 8.9 to 13.5 A Make: BCH /L&T/Legrand
45S&F in repair thermal overload relay of RR 22.0 to 30.0 A Make: BCH /L&T/Legrand
46S&F in repair auxiliary contact block 2 NO+2 NC aux Make: BCH /Legrand/L&T
47S&F in repair auxiliary contact side mounting 1 NO+1 NC Make BCH /L&T/Legrand
48Supply, install, test and commissioning of compact type factory made CPRI Approved LT Panel board (Minimum size of panel board 1.80m x 1.80m x 0.75m), Indoor type,make as per list enclosed in particular specification, floor mounted as per equipment made out of CRCA sheet of 3.15mm thick outer sheet cover and 2mm thick inner comprtment sheet cover with 50x50x6 mm of angle iron frame by using PCC 1:2:4 type B-1(using 20mm graded stone) for fixing of panel and duly painted with powder coating over a coat of red oxide primer all over with canopy totally enclosed weather, dust and vermin proof with separate compartment for MCCBs with locking arrangement on front and back side of panel suitable for 3 phase 4 wire LT AC, 50 Hz, 415 Volts including suitable copper bus bar. PCC foundation/platform as per manufacturer guide lines for installing the panel board complete for accommodating the following accessories. Incoming:-(a) MCCB 200 amps, four pole ,35 KA 01 No (b) LED Multi function meter - 01 No (c) selector switch -01 nos for Multifunctional meter (d)CT 100/5 - 03 Nos (e) LED type Indicating lamp R, Y, B, 415 V (set of 3 ) -01set (f)copper bus bar TPN of rating not less than the 1.5 times the rated capacity of the incomer MCCB with necessary wiring including wiring material .Outgoing:-(a) MCCB fixed thermal and fixed magnetic type, 63 amps, four pole ,25 KA - 01 No (b) MCCBs fixed thermal and fixed magnetic type 100 A, 4 pole,25KA, 50HZ, 415V - 02 nos(c) MCB TPN 63A, C curve ,10KA -02 Nos
49Supply , install , test and commissioning of compact type factory made CPRI Approved LT Panel board (Minimum size of panel board 1.80m x 1.80m x 0.75m), Indoor type, make as per list enclosed in particular specification,floor mounted as per equipment made out of CRCA sheet of 3.15mm thick outer sheet cover and 2mm thick inner comprtment sheet cover with 50x50x6 mm of angle iron frame by using PCC 1:2:4 type B-1(using 20mm graded stone) for fixing of panel and duly painted with powder coating over a coat of red oxide primer all over with canopy totally enclosed weather, dust and vermin proof with separate compartment for MCCBs with locking arrangement on front and back side of panel suitable for 3 phase 4 wire LT AC, 50 Hz, 415 Volts including suitable copper bus bar. PCC foundation/platform as per manufacturer guide lines for installing the panel board complete for accommodating the following accessories. Incoming:-(a) MCCB 125 amps, four pole ,25 KA 01 No (b) LED Multi function meter - 01 No (c) selector switch -01 nos for Multifunctional meter (d)CT 100/5 - 03 Nos (e) LED type Indicating lamp R, Y, B, 415 V (set of 3 ) -01set (e)copper bus bar TPN of rating not less than the 1.5 times the rated capacity of the incomer MCCB with necessary wiring including wiring material .Outgoing:-(a) MCCB fixed thermal and fixed magnetic type, 32 amps, four pole ,25 KA - 04 No
50S&F in replacement, higher crank power , high charge retention, superior spill resistant,12V, 180 AH battery complete all as specified and directed. (Brand-Exide/ HBL/OKAYA. Note : Old U/S battery to be deposited to Store.
51Supply and fixcopper cable of size 25 sq mm, 4 core 1100V ,including pvc pipe with provision ofclampsincluding taking down old unserviceable cable all as specified.
52Supply and fixcopper cable of size 50 sq mm, 4 core 1100V including provision pvc pipe with provision ofclampsincluding taking down old unserviceable cable all as specified.
53Supply and fix bimetal over load relay of range 20 to 32 Amps for any capacity ofEOT/HOT crane including taking down old unserviceable one all as directed and specified.
54Supply and fix bimetal over load relay of range 16 to 25 Amps for or any capacity ofEOT/HOT crane including taking down old unserviceable one all as directed and specified.
55S& F in repair thermal overload relay of range RR 3.8 to 6 A.
56S& F in repair thermal overload relay of range RR 6 to 9.3 A.
57S& F in repair thermal overload relay of range RR 8.9 to 13.5A.
58S& F in repair thermal overload relay of range RR 22 to 30 A.
59S&F in repairpower contactor of capacity 40 Amps, AC3, 415 volts main contactor coil voltage 110 Voltincluding taking down old one all as directed.
60S&F in repairpower contactor of capacity 12 Amps, AC3, 415 volts main contactor coil voltage 110 Voltincluding taking down one all as directed.
61S&F in repair power contactor of capacity 9.1 Amps, AC – 03, 415 volts main contactor coil voltage 110 Volt including taking down old one all as directed.
62Dismantling and taking down of electric motor of 01 ton lift , 415 Volts3 phase , 10 HP capacity, disconnection of incoming electric connection from panel, gear box and transported to workshop , stripping out burnt wiring, cleaning slots and rewinding the motor with super enameled copper wire as per existing size and gaugeincluding insulating materials and varnishing, replacing worn out bearing as per existing size, reassembling the motor after rewinding and mounting on its original position including replacing the old unserviceable nuts, bolts and tested completed all as directed .
63Dismantling ofgear boxof 01 ton capacity lift removing it from its position carefully and transporting to the work shop and refixing the same to its original positions after servicing andremantalingofworn out gears and followers and machining the gear shaftcomplete all as directed. Note: (i) Consumable stores like cotton waste/cleaning materials , metal filling , machining , packing seals,gasket , nuts, bolts and washers and transportationfrom site to work shop are deemed to be included in rate quoted.(ii) bearingto be measured and paid separately
64Supply and fix non friction spherical Ball bearing as per existing sizesfo 01 ton liftgear box including taking down old unserviceable one all as directed and specified.
65S&FFully Automatic star delta startercontroller(IP54) 100 HP capacity ,415coil voltage withrelay range up to 160A Amps including combined V/A meter,voltmeter selector switch, star delta timer and SPPsuitable for 100 HPcontroller set including taking down old star delta starter all as specified and directed.
66M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 32x6 mm GI iron strip earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (light grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with RCC cover slab of size 42cm x 42 cm and 10mm thick , funnel,wire mesh, 20 mm bore galvanized iron pipe (light grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.(note :- 7.5 mtr GI strip with 40 mm GI pipe is included in above item)
67Supply & fixing in replacement of earth continuity conductor GI strip 32x6 mm all as directed.
68Supply , install , test and commissioning and Replacementof Compact type factory made CPRI Approved LT Panel board,Indoor type,make as per list enclosed in particular specification,floor mounted as per equipment made out of CRCA sheet of 3.15mm thick outer sheet cover and 2mm thick inner comprtment sheet cover with 75x75x6 mm of angle iron frame by using PCC 1:2:4 type B-1(using 20mm graded stone) for fixing of panel and duly painted with powder coating over a coat of red oxide primer all over with canopy totally enclosed weather, dust and vermin proof with openable shutters/compartments with locking arrangement on front and back side of panel suitable for 3 phase 4 wire LT AC, 50 Hz, 415 Volts including suitable copper bus bar. PCC foundation/platform as per manufacturer guide lines for installing the panel board complete for accommodating the following accessories. Incoming:-(a) MCCBfixed thermal and fixed magnetic type 250 amps, four pole ,35 KA 01 No(b) On load change over switch 250 Amps , 4 pole - 01 No(c) LED Multi function meter - 01 No (d)CT 100/5 - 03 Nos (e) LED type Indicating lamp R, Y, B, 415 V (set of 3 ) -01set (f)copper bus bar TPN of rating not less than the 1.5 times the rated capacity of the incomer MCCB with necessary wiring including wiring material .
69Outgoing:-(a) MCCB fixed thermal and fixed magnetic type, 63 amps, four pole ,25 KA - 01 No (b) S&FFully Automatic star delta startercontroller (IP54) 100 HP capacity, 80 KW,415 with suitablecontactors, MPCB, coil voltage and relay range 90-160 Amps including combined V/A meter,voltmeter selector switch, star delta timer and single phase preventor with 3 indicator light (for start,stop and trip). All accessories V/A meter, Auto/manual selector switch, indicator light (for start, stop and trip) and start and stop button(Make- L&T) will be fixed on outer cover of respective compartment. - 02 NosNote:-The connection between contactors of both 100HP starter should be such that only one starter will be operated at a time. (c) S&FFully Automatic star delta starter controller (IP54) 25HP capacity, 20 KW, 415 with suitablecontactors, MPCB, coil voltage and relay range 24-38 Amps including combined V/A meter,voltmeter selector switch, star delta timer and single phase preventor with 3 indicator light (for start,stop and trip). All accessories V/A meter, Auto/manual selector switch, indicator light(for start,stop and trip) and start and stop button will be fixed on outer cover of respective compartment - 01 Nos(d) MCCBs fixed thermal and fixed magnetic type 160A, 4 pole, 25KA, 50HZ, 415V - 02 nos mounted on 100HP starter compartment.(e) MCCBs fixed thermal and fixed magnetic type 63A, 4 pole, 25KA, 50HZ, 415V - 01 nosmounted on 25HP starter compartment. (f) MCB TPN 63A, C curve ,10KA -02 Nos

AI Tender Summary

OUR REF NO 51224103
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 06-10-2025
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair And Maint Of Lifts And Eot Cranes Of Various Capacities Installed At Technical Magazine Lc Area At Pxe And Itr Chandipur
Basic Detail
Tender No 8210/A/E8
Bidding Type Tender
Location
City chandipur
State Odisha
Key Dates
Publish Date 15 Sep 2025
Submission Date 06 Oct 2025
Open Date 07 Oct 2025
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 80000
Exemption Available
Document List
a801c80f-269f-40c8-8036-424053f3f80f.html
BOQ_818398.xls
Tenderdoc8210A.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 07, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a801c80f-269f-40c8-8036-424053f3f80f.html

xls

BOQ_818398.xls

pdf

Tenderdoc8210A.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders