| Sl. No. | Item Description |
| 1 | Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete allas directed. |
| 2 | M & L for coloured Glazed ceramic tiles in vertical surface area exc 0.06 Sqm andn exc 0.18 Sqm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed. |
| 3 | M & L for Non Skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tileexceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. |
| 4 | M & L for coloured joint free non skid tiles 7 to 8 mm thick (Square / Rectangular) area of each tileexceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. |
| 5 | M & L for coloured joint free non skid tiles 7 to 8 mm thick (Square / Rectangular) area of each tileexceeding 0.11 sqm but not exceeding 0.18 sqm as in vertical surfaces such as skirtings, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. |
| 6 | M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 7 | M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm,n vertical surfaces such as skirtings, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.. |
| 8 | M & L for dark shade / Double Charged / Ultra charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchs complete all as specified and directed. |
| 9 | M &L for dark shade / Double Charged / Ultra charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, such as skirtings, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchscomplete all as specified and directed. |
| 10 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & directed. |
| 11 | M & L for granite (of any colour)20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grindingand polishing as in kitchen platform, counter for wash basin, flooringand all other similar works complete all as specified and directed. |
| 12 | M & L for granite (of any colour)20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in skirting, steps risers, wall dado and similar works aand all other similar works complete all as specified and directed. |
| 13 | M & L for Machine cut kota stone slab flooring 20-25mm thick ini flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 14 | M & L for Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed withover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 15 | M & L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 16 | M & L for 15mm thick screed bed or bedding layer in cement mortar (1:6)for laying floor finishes like tiles etc complete all as specified and directed. |
| 17 | M & L for rendering 10 mm thick in CM (1:4) on fair faces of brick workcomplete all as specified and directed. |
| 18 | M & L for 20mm thick screed bed or bedding layer in cement mortar (1:4)for laying floor finishes like tiles etc complete all as specified and directed. |
| 19 | Taking up or down steel tubing / CPVC Pipes and connection including cleaning for refixing or removed to store, complete all as specified and directed. |
| 20 | (a) 16 mm bore |
| 21 | (b) 20 mm bore |
| 22 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified & directed of following OUTER DIAMETER sizes :- |
| 23 | (a) 16 mm bore |
| 24 | (b) 20 mm bore |
| 25 | Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good ,cutting n, exc. 10cm girth complete all as specified and directed. |
| 26 | S & F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white,including trap and connection to drain and flushing pipe (excluding flushing cistern)including seat cover with flat bottom and mild steel chromium plated or aluminium hinging devices for pedstal pan complete all as specified and directed. |
| 27 | S & F in repair vitreous China squatting pan, \"Orissa patteren, size 580 x 440 mm white, with integral footrests (excluding flushing cisteren and flush pipe) complete all as specified and directed. |
| 28 | S & F in repair vitreous China wash basin white, flat back, size 580X450 mm including cutting for pinning in ends of brackets,complete all as specified and directed. |
| 29 | S & F in repairs Vitreous China full stall urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 30 | S & F in repairs 10 litre capacity PVC low level flushing cisternwith all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed. |
| 31 | S & F in repair PVC connection 15mm size PTMT nuts of length 450 mm complete all as specified and directed. |
| 32 | S & F in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 33 | S & F in repair of two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed. |
| 34 | S & F in repair of two way bib cock chromium plated fancy type 15 mm bore complete all as specified and directed. |
| 35 | S & F in repair 15 mm bore fancy type bib taps long bodycast copper alloychromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 36 | S & F in repairs to health faucet with 1200 mm long flexible mild steel tube 80 mm dia with wall hook complete all as specified and directed. |
| 37 | S & F in repair Soap dish, any type, fixed to plugs with chromium plated brass screwscomplete all as specified and directed. |
| 38 | S & F in repairs acrylic shelfhaving size of 56 cms x 13 cms with chromium plated bracketbelow WHB mirror complete all as specified and directed. |
| 39 | S & F in repairs 15 mm bore overhead shower Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified & directed. |
| 40 | S & F as in repair grating round 150mm size of PTMT (minimum 100 gms) with waste hole of PTMT complete all as specified and directed. |
| 41 | S & F in repair 15 mm bore pillar taps cast copper alloy,with capstan heads,chromium plated,screwed down, fancy type, high pressure, with or without lettred \"HOT or COLD\" with long screwed sunk and fly nuts complete all as specified and directed. |
| 42 | S & F in repair CP wall mixer 3 in 1 System with provision for hand shower and over head shower and including 1.5mlong tele shower screwed for iron pipe or CPVC Pipes or for brass ferrule and fixed complete all as specified and directed. (Make : Jaquar Queen Series Cat Part No - QQT - 7281 or equivelant) |
| 43 | M&L in repair for fancy type 15 mm borecentral hole basin mixture with \"U\" shaped round casted spout with 3\" long pipe connection with aerator complete all as specified and directed. |
| 44 | S & F in repairs Tubular towel rail, 20mm dia, D type, 60cm long between flanges brass chromium plated complete all as specified and directed. |
| 45 | S & Fin repairs CP Towel Ring round with round flange and not less than 280 gms complete all as specified and directed. |
| 46 | S & F in repairs CP Toilet Paper holder all as per cat part complete all as specified and directed. |
| 47 | S & F in repairs 5 mm thick glass mirror with double coat for protection and longevity grounded edges for safety and silver plating on the back for better reflection mm thick of size 800 x 600 mm bevelled edge mirror of selected quality glass having decorative PU frame and fixed to walls using hidden studs complete all as specified and directed. |
| 48 | Taking downcement plaster ofany description from brickwall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as directed. |
| 49 | M & L for 15 mm thick plaster in CM(1:6) on brick work / RCC concrete surfaces of wall and finish the surfaceeven and smooth without using extra cement complete all as specified and directed. |
| 50 | M & L for 5 mm thick plaster in CM(1:3) on brick work / RCC concrete surfaces of ceilings complete all as specified and directed. |
| 51 | M & L for preparation of newly plastered ceilingsurfacesand applied three coats of white wash complete all as specified & directed. |
| 52 | M & L forpreparation of newly plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant priming paintcomplete all as specifed and direcetd. |
| 53 | Demolition of precast concrete block walling and similar items i.e. ashlar facing dressing stone work, precast concrete articles etc of any description and in any position built in cement mortar including all quoins, arches and pillars etc. complete all as specified & as directed. |
| 54 | M & L for Precast cement concrete block masonry with solid blocks Type C1 1:3:6 (20mm graded aggregate), exc. 10cm in width and setting in Cement mortar 1:6 complete all as specified & as directed. |
| 55 | M & L for rendering 15 mm thick in CM 1:4 on concrete / fairsurfaces of block masonary and including mixing water proofing compound as per manufactureres instructions and finished even and smooth without using extra cement complete all as specified and directed.Note :- Water proofing compound shall be measured and paid for seperately under appropriate item of Sch \"A\" as supply only |
| 56 | Supply onlyLiquid water proofing compound complete all as specified and directed. |
| 57 | M & L forpreparation of newly plastered wall surfaces and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 58 | Complete removal of existing treatment on wall (any number of layers ) by scarping with steel scrapersor any other mean and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 59 | Demolition and breaking up drain pipes upto 100/110 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed |
| 60 | Demolition and breaking up drain pipes upto 75 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed |
| 61 | Supply and fixing of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed. |
| 62 | Supply and fixing of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed. |
| 63 | Supply and fixing of PVC (SWR) junction single, (single T) equal or unequal provided with access door suitable for 110mm bore PVC pipes complete all as specified and as directed. |
| 64 | Supply and fixing of PVC (SWR) bends any radius suitable for 110mm bore PVC pipes with access door complete all as specified and as directed. |
| 65 | Supply and fixing of PVC (SWR) bends any radius suitable for 75mm bore PVC pipes with access door complete all as specified and as directed. |
| 66 | Supply and fixing of PVC (SWR) vent cowl for 110mm bore PVC pipes complete all as specified and as directed. |
| 67 | Supply and fixing of PVC (SWR) WC connector bent type for 110mm bore PVC pipes complete all as specified and as directed. |
| 68 | Supply and fixing of PVC (SWR) for 75mm Diameter of outlet floor trap, plain with grating including jointing with solvent cement etc complete all as specified and as directed. |
| 69 | Supply and fixing of PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 70 | Dismantling of water tanks and removing to store having Capacity of Exc 500 litres and n.exc 1000 litres complete all as specified and directed. |
| 71 | Dismantling of water tanks and removing to store having Capacity of Exc 1000 litres and n.exc2000 litres complete all as specified and directed. |
| 72 | S & F for 500 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed. |
| 73 | S & F for 1000 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed. |
| 74 | S & F for 2000 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed. |
| 75 | S & F in repairs 20 mm bore dia gun-metal,globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 76 | M & L for preparation of old painted steel surfaces of any description not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified. |
| 77 | Excavating in post holes (or similar holes) in soft / loose type of soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed |
| 78 | M & L for PCC Type D2 1:4:8 (40mm graded aggregates)as in foundation, filling and mass concrete complete all as specified and directed. |
| 79 | S & F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 80 | S & F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mmbowl size 410 mm x 330mm x 160mm complete all as specified and directed. |
| 81 | S &F in repairs 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 82 | S & F in repairs ofBib tap fancy type Bore dia of pipe 15mm standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 15mm-90gms). |
| 83 | S & F in repairs ofPillar tap fancy type Bore dia of pipe 15mm standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight 15mm-90gms). |
| 84 | S & F in repairs of Stop valve Bore dia of pipe 15mm standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight 15mm-90gms). |
| 85 | S & F in repairs of Angle Stop valve Bore dia of pipe 15mm standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 15mm-90gms). |
| 86 | S & F in repairs of Ball valves 15mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight 15mm-142gms) |
| 87 | S & F in repairs ofBall valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm-210 gms) |
| 88 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 89 | S & F of mild steel Fe 410-W (Grade-Fe 250) quality A of Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and directed. |
| 90 | M & L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and directed. |
| 91 | Taking down of Wall panelling and similar work complete all as specified and as directed. |
| 92 | S & F of Hollow PVC Wall panelling consisting of single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 93 | S & F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 94 | M & L for Preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 95 | M & L for Preparation of old painted surface of wood and wood based materialany description and in any position over 10 cm width or girth and Material and labour for applying one coat of synthetic enamel paint complete all as specified and directed. |
| 96 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc from water tanks havingCapacity Exc 250 lit & n exc 500 lit complete all as specified and directed. |
| 97 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc from water tanks havingCapacity Exc 500 lit & n exc 1000 lit complete all as specified and directed. |
| 98 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc from water tanks havingCapacity Exc 1000 lit & n exc 2000 lit complete all as specified and directed. |
| 99 | M&L for Treatment to Walls complete all as specified and directed. |
| 100 | Surface PreparationSurface must be thoroughly cleaned, free of dust, grease etc and washed well with water. The surface to be checked for cracks, hollowness and loose plastered areas etc if any. All loose plaster and cracks larger than 10 mm width to be repaired with polymer modified mortar using Dr. Fixit Pidicrete URP. The cracks up to 5 mm to be treated with Dr. Fixit Crack-X Paste and the larger ones up to 10 mm with Dr. Fixit Crack-X Shrinkfree. |
| 101 | PrimingAfter the proper surface preparation and curing of repaired areas wash the surface well and maintaining it in saturated surface dry condition proceed for priming using Dr. Fixit Primeseal diluted in 2:1 ratio with water(2 parts Primeseal diluted with 1 part water). Maintain the spreading rate of 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. |
| 102 | CoatingBrush apply one coats of Dr. Fixit Raincoat Waterproof Coating without any dilution Maintain the spreading rate of 3.5-4.0 sq mtr per litre / coat application to achieve about 120-130 microns DFT. The second coat of Dr. Fixit Raincoat Classic Topcoat to be apply with interval of 6-8 hours without any dilution. Maintain the spreading rate of 7-8 sq mtr per litre / coat application to achieve about 50-60 microns DFT. |
| 103 | M & L for Treatment to Roof Surface complete all as specified and directed. |
| 104 | Surface PreparationRoof substrate must be washed with water to remove all dirt, dust, chalking and waste products.Stagnant water due to undulation in the roof surface should be marked and repaired with PMM. All joints / corners / penetration points, rainwater outlets, marble / tile strip joints should be grouted with PMM. |
| 105 | WATER PROOFING APPLICATIONAll joints / corners / penetration points, rainwater outlets, marble / tile strip joints and parapet wall and floor junction joint (corner rounding) over the length shall be treated prior to all application of Dr. Fixit Roofseal Classic by reinforcing minimum layer of 50 – 100 mm width, with 45 gsm glass fibre mesh cut to size, embedded in between the two coats of Dr. Fixit Roofseal Classic to provide additional strength to the treatment. Allow the coating to dry for 4- 6 hrs. before application of second. Apply a coat of Dr. Fixit Roofseal Classic (diluted with water in the ratio 2:1) as Self-Priming 9 - 10 Sq.mtr / litre. Allow coating to dry for 4 hours prior to applying first coat & second coat. Apply two coats of Dr. Fixit Roofseal Classic @ 2.0 - 2.2 Sq.mtr / litre / coat, with the same application coverage. Place a 45-gsm glass fibre mesh with a size of 2.5 mm by 2.5 mm between the first coat and second coat. Application direction of second coat should be perpendicular to that of the first coat without water dilution to deliver a DFT of 450– 500 micron. |
| 106 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil complete all as specified and directed. |
| 107 | Returning, filling in, including spreading leveling watering and well ramming inlayers not exceeding 25 cm in any type of soil complete all as specified and directed. |
| 108 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed. |
| 109 | M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed.Note: Punned thickness shall only be measured and paid |
| 110 | Supply and lay un-reinforced precast concrete cable cover , class , LV , Type Iflat size 250 x 150x 40 mm laid dry in treches over under ground cables complete all as specified and directed. |
| 111 | S & FGI pipe,light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection complete all as specified and directed. |
| 112 | Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. completeall as specified and directed of following size |
| 113 | - do- as per Item 103here in above but of size 4Ccore 16 sqmm |
| 114 | - do- as per Item 103 here in above but of size 3.5 core 95 Sqmm |
| 115 | - do- as per Item 103here in above but of size 3.5 core 240 Sqmm |
| 116 | - do- as per Item 103here in above but of size 3.5 core 35 Sqmm |
| 117 | - do- as per Item 103 here in above but of size 3.5 core 50 Sqmm |
| 118 | M&L for Disconnecting, taking out, removing old existing unserviceable LT underground cableof any size all as specfied and directed |
| 119 | Fabricate, Supply, Install, Testing and Commissioning LT Panel Board outdoor type factory made CPRI tested made out of CRCA sheet steel enclusure 3.15 mm thick including aluminiumbus bar 4 pole for all incomingMCCB to outgoing MCCB , wiring of rated capacity PVC insulated copper conductor cable for SPNs, front back openable, , IP 65 , Gasketinsulators, fasteners etc with Digital Ammeter & Voltmeter, selector switches for voltmeter and ammeter, indicator lamp RYB (01 Set), moulded (resign cast) CTs , copper tin spreader link, spring washer, busbar spacing should be 30mm minium for phase to phase , including MS Angle Frame of size 50x50x5 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc, taking down old LT panelcomprising for the following :-Note:The contractor shall submit detail Schematic Layout of the Panel Board for approval from Engr-in-Charge before procurement.Location : (BG line )(a) AluminiumBus Bar 250 A rating for 3 Phase and 125 A for Neutral - 01 Set(b) 3 Line digital multimeter for measuring basic electrical parameter-1(c) LED Indication Lamp for 3 Phasefor incoming and for all outgoing (d) MCCB 4 Pole160Amps 16KA, Ics=100%ICu, thermal adjsutable, shortcircuit adjsutable- 01 Nos(01 No for Incoming)(f)MCCB 4 Pole 63 Amps 16 KA, Ics=100%ICu, thermal adjsutable, shortcircuit adjsutable- 05Nos |
| 120 | Supply, installation, testing and commissioning CPRI approved weather and vermin proof BUS bar LT panel box factory fabricated out door cubicle type(KIOSK type ) , front and back openable , air vent , totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessarywith PCC foundation and civil work and aluminium bus bar for 3 phase & neutral of cuurent capacity 240Amounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :-only incoming MCCB of 160A, Thermal Adjustbale, Magetic adjustbale , ICs=100% Icu |
| 121 | Fabricate, Supply, Install, Testing and Commissioning LT Panel Board outdoor type factory made CPRI tested made out of CRCA sheet steel enclusure 3.15 mm thick including aluminiumbus bar 4 pole for all incomingMCCB to outgoing MCCB , wiring of rated capacity PVC insulated copper conductor cable for SPNs, front back openable, , IP 65 , Gasketinsulators, fasteners etc with Digital Ammeter & Voltmeter, selector switches for voltmeter and ammeter, indicator lamp RYB (01 Set), moulded (resign cast) CTs , copper tin spreader link, spring washer, busbar spacing should be 30mm minium for phase to phase , including MS Angle Frame of size 50x50x5 mm structure at bottom,minimum 0.8 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc, taking down old LT panelcomprising for the following :-Note:The contractor shall submit detail Schematic Layout of the Panel Board for approval from Engr-in-Charge before procurement.Location :LT panel-1 (FSH)(a) AluminiumBus Bar 400 A rating for 3 Phase and 100 A for Neutral - 01 Set(b) 3 Line digital multimeter for measuring basic electrical parameter-1(c) LED Indication Lamp for 3 Phasefor incoming and for all outgoing (d) MCCB 4 Pole 400 Amps 36 KA, Ics=100%ICu, thermal adjsutable, shortcircuit adjsutable- 01 Nos(01 No for Incoming)(e)MCCB 4 Pole 160 Amps 16 KA,Ics=100%ICu, thermal,short circuit protection - 2Nos( outgoing)(f)MCCB 4 Pole 100 Amps 16 KA,Ics=100%ICu, thermal,short circuit protection - 4Nos( outgoing)(f)MCCB 4 Pole 63 Amps 16 KA,Ics=100%ICu, thermal,short circuit protection - 4Nos( outgoing)(f)MCCB 4 Pole 25 Amps 16 KA,Ics=100%ICu, thermal,short circuit protection - 2Nos( outgoing) |
| 122 | Material and labour for bring the van mountedfull automated underground cablefault locator machine at site forfind outHT/LTcable faultin underground completely and also finding one phase fault in cableall as specified and directed by Engineer in Charge. Note: (a) Fault machine,cable & T&P required shall be arranged by the contractor.(b) Cable jointing kit for LT is measured separately |
| 123 | M&L for refreshing of incommingand all outgoingXLPE cable of any sizeincluding excavationforremoving cable loop , refreshing of exsiting all cable by removing insulation ,including removing old damaged lugs and fixing of suitable size lugs, PVC conncetor,dressing of all cables . nuts ,bolts,washerto all incomming and outgoing MCCB , insulating all bare conductor with insulating cable of suitable colour all as sepcfiedc and directed by Engineer-in-charge.Note:1. Lugs and insulation tap will be measured as separate item. |
| 124 | M&L for restraining of HT/LT Over headaluminium conductor of any size including taking down aluminium conductor and refixing the sameconductor to insulator including aluminium bindingworks for connceting insulator and conductor , tighting of pin insulator , MS channelrefixing of outgoing conductor ,removing all old unservicable tapping from pole all as specfied and directed. |
| 125 | S&F pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 100mm height and 65mm dia suitable for working pressure upto and including 1100 volts gradefor LT lines fixed on poles complete all as specified and as directed. |
| 126 | supply and fix shackle/ disc type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade all as specfied and directed |
| 127 | Supply and fix in repiars the following items and disconnecting,taking out the old unserviceable one, including necessary replacemnet of lugs ,nuts,bolts lugs , cutting existingCRCA sheet of any size and capacity wherever reqd complete all as specified and directed. :- |
| 128 | MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustableover load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 63 Amps 16 KA. |
| 129 | MCCB Thermal Magnetic release Ics=100% of Icu, Adjustableover load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 100 Amps 16 KA. |
| 130 | MCCB Thermal Magnetic release Ics=100% of Icu, Adjustableover load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 160 Amps 36 KA. |
| 131 | MCCB Thermal Magnetic release Ics=100% of Icu, Adjustableover load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole250 Amps 36 KA. |
| 132 | MCCB Thermal Magnetic release Ics=100% of Icu, Adjustableover load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 400 Amps 36 KA. |
| 133 | Supply install testing,commissioning of CRI tested Copper earthing electrode of length 3 metres, 40mmdia and back fill compoundof 50kgs ,and conductive gel to retain moisture should be filled layer wise and inter connceted by exothermic brazing &copper strip of size 32x6mm should be suppllied and fix upto testpoint protected by GI pipe of size 50mm dia up to test pointincluding disconnection of old earth strip and fix to new chemical earthing, PCC earth pit of standared size as per SSR part-1and submmision of earth results and painting of Date of test , valueobtain at site and all specified and as directed. |
| 134 | Note :- (i)Earthing shall be tested as specified incasul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing,if the desired earth resistance is not obatined the earthing wiil be re done by thecontractor complete all as specified and directed. |
| 135 | M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in any type of rock vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip 25 X 4 mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle completeall as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’NOTE -The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe complete all as specified and directed. |
| 136 | Maintaning of HT/LT over head lines by trimming the of tree branches tuching to the HT/LT over head conductors lines upto 03 mtr away from the live conductors surrounding area complete all as directed at site complete. Note :- cost of labours deemed to be including cutting the tree branches and depositing the tree branches away from site all as specfied and directed bt Enginner -in-charge |
| 137 | M&L for cable jointing kitLT 1.1KV3.5C straight through joint 185sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 138 | M&L for cable jointing kitLT 1.1KV3.5C straight through join 150 sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 139 | M&L for cable jointing kitLT 1.1KV3.5Cstraight through joint 120sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 140 | M&L for cable jointing kitLT 1.1KV3.5Cstraight through joint 95 sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 141 | M&L for cable jointing kitLT 1.1KV 3.5Cstraight through joint 70 sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 142 | M&L for cable jointing kitLT 1.1KV 3.5Cstraight through joint 50sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 143 | M&L for cable jointing kitLT 1.1KV 3.5Cstraight through joint 35sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 144 | M&L for cable jointing kitLT 1.1KV 3.5Cstraight through joint 25sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 145 | M&L for cable jointing kitLT 1.1KV 3.5Cstraight through joint 16sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 146 | M&L for cable jointing kitLT 1.1KV 2Cstraight through joint16 sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 147 | M&L for cable jointing kitLT 1.1KV2 Cstraight through joint 10sqmm,heat shrinkable typewith all accessories all as specfied and directed. |
| 148 | Dismantling of oldunserviceable stay assembly, and Supply and fix Stay assembly complete with all accessories as shown in electrical plate no. 1 of SSR Part - I ,1991, using stay rod 16 mm dla including stay wire. Note :- Excavation , earth work , foundation concrete ,loop insulator, stay clamps, for the new stay shall be measured and paid separately under respective item of schedule complete all as specified and directed. |
| 149 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flat twin core cable of size 6 Sqmm complete all as specified and directed. |
| 150 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flat twin core cable of size 10 Sqmm complete all as specified and directed. |
| 151 | Dismantling of old deterioratedACSR Conductor , ofany size , any type and supply and fix aluminium conductor , steel reinforced (ACSR) , ofany size, any type , as per existing one andstringingproperlyon the insulators and binding withaluminium wire ,connectors , jumpersetc complete., Note :- Measurement and payment shall be made by measuring horizontal distance between centres of two adjacent polesand adding3 %for sag , jointings, jumpers etc. complete all as specified and directed. |
| 152 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail