| 1 | Demolishing CLC block masonary work manually/ by mechanical means including stacking of serviceable material if any and disposal of unserviceable material within 1Kilometres lead as per direction of Engineer-in-charge. |
| 2 | In cement mortar |
| 3 | Reinforcedcementconcreteworkinbeams,suspended floors,roofshaving slopeup to 15°landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement,with 1:1.5:3 (1cement: 1.5coarsesand (zone-III)derivedfromnaturalsources: 3gradedstone aggregate 20mm nominalsize derivedfrom natural sources). |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 5 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 7 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 9 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | 12 mm cement plaster of mix : |
| 11 | 1:6 (1 cement: 6 fine sand) |
| 12 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 13 | 1:6 (1 cement: 6 fine sand) |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 16 | Two coats |
| 17 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 18 | Two coats |
| 19 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 20 | Providing and fixing Fibreglass Mesh at the Joints of masonary wall and as per direction of the Engineer-in- Charge |
| 21 | Dismentalinga/removing and fixing of existing aluminium work for doors, windows, ventilators and partitions of extruded built up standard tubular sections and other sections and refixing it at other location by fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (New Snap beading, new glass, new particle board,dash fastner if any used for refixing of partition to be paid separately) :Note: 1- The dismentalling and re-assembling of aluminium work will be carried out within the University .2. Unserviceble Material will be the Property of the Contractor |
| 22 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 23 | For Fixed Portion:Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 24 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 25 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 26 | Pre-laminated particle board with decorative lamination on both sides |
| 27 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 28 | With float glass panes of 5.00 mm thickness |
| 29 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 30 | Upto 5mm depth and 5 mm width |
| 31 | Providing and fixing aluminiumhandle of outer dia 100mm with SS screws etc. complete as per direction of Engineer- in-charge |
| 32 | Powder coated minimum thickness 50 micron aluminium |
| 33 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 34 | 150x10 mm |
| 35 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 36 | Twin rubber stopper |
| 37 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 38 | With stainless steel cover plate minimum 1.25 mm thickness |
| 39 | Providing and fixing Stainless Steel dash fastener of 10 mm dia commprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in Aluminium frame complete as per direction of Engineer-in-charge. |
| 40 | Providing and fixing of wooden cabinet with openable shelf for files storage made of 19 mm thick block boardwith 1 mm laminate finish both side (make Greenlam/Century) with storage cabinet having openable shutters fitted with soft close hinges, locking system (make Hittich/Ebco) as per approved design.Note: 1.Vertical surface shall be measured for payment.2.Cabinet shall be supplied with necessary accessories and hardware such as individual locks, SS handles, magnetic ball catchers, SS tower bolts, individual locks etc. of approved makes screwed as per direction of Engineer-in-charge |