| 1 | Supply and Installation: Switch should have 24x 10/100/1000BASE-T ports Ports with4 10G SFP+ ports for uplink purpose. Switch should have Console Port (RJ-45) for out-of-band CLI management, provide a direct, physical connection to the switch for management tasks, which can be especially useful if remote management is not possible, Should have 16K MAC Address and 12MB Packet buffer memory. Switch should have 128 Gbps Switching capacity and 95 Mpps packet forwording rate. Power Support and Energy Efficiency: The Switch should support Power Input100 to 240 VAC 50/60 Hz with Maximum Power Consumption should be not more than30 W , while Standby Power Consumptionshould not be more than9 W. Operating Temperature should be-5 to 50 °C (32 to 122 °F) with Storage Temperature • -20 to 70 °C (-40 to 158 °F), Support Surge Protection upto6 kV surge protection on all Ethernet access ports. Support Energy-Efficient Ethernet (EEE) standard and save power with shutoff LED and port shut-off and power on link while there is no activityand draw power only as per cable length used , Also the complete switch can be hibernet during off period i.e. Night to save power. Layer 2 feature: support 802.3x Flow Control with HOL blocking, Switch shouldsupport802.1D, 802.1w , 802.1s. It also supportRoot Guard andLoop Guard Switch should support jumbo Frame: up to 12 Kbytes. Support 802.1AX Link Aggregation,Max. 8 groups per device, 8 ports per group. Port Mirroring (One-to-One, Many-to-One) , alsoSupports Mirroring for Tx/Rx/Both, Should support Remote Switched Port Analyzer, to takes a mirrored copy of network traffic from within the switch to be sent to a destination. Layer 3 feature: Switch should support 4 IP interfaces , support Static Route,124 IPv4 static route entries • 50 IPv6 static route entries. Should support Queue HandlingStrict Priority (SP),Weighted Round Robin (WRR) andStrict + WRR ,Bandwidth Control with min granularity 10/100/1000 is 16 Kbps). Switch should support QoS based on Time , CoS ,Switch port,Inner/outer 802.1p Priority ,MAC address,Ether Type,IP address,ToS/IP Preference,DSCP,Protocol type,TCP/UDP port, IPv6 Traffic Class, support64MAC addresses per portfor connected devices, thus preventing unauthorized access and mitigating security risks. Broadcast/Multicast/Unicast Storm Control for effectively manage and mitigate the impact of excessive traffic on their network infrastructure, ensuring optimal performance and reliability by using any specifc protocol.SupportDHCP Server Screening to prevent rogue DHCP servers from distributing incorrect or malicious IP configuration information to network. Dynamic ARP Inspection to avoidtraffic interception, packet sniffing, or denial of service attacks. Switch should support IP-MAC-Port bindingin assiociation with IP Source Guard, DHCP snooping and Dynamic ARP Inspection (DAI). Support SSL, TLS 1.0/1.1/1.2, SSH.Switch should support Cable Diagnostics, Switch should carry Safety Protocl i.e. cUL, CB, CE, CCC, BSMI andEMI/EMCi.e. CE, FCC Class A, C-Tick, VCCI, BSMI, CCC. . Make- Cisco/D-Link/Juniper complete in all respect with the prior approval of Engineering In Charge. |
| 2 | Supply and Installation: Wall Mount 9U x 550 W x 500 D, 1U Cable Manager, Roof Mounted Fan Unit / 90 CFM / 230V AC,6 Way 5 Amp Power Distribution Unit,Mounting Hardware Kit,Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility, and maximizes the usable mounting space,Depth adjustable mounting slots,Front Glass Door with Lock, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with Seven Tank pretreatment process meeting all industry standards, Grounding and Bonding Options. 100% assured compatibility with all equipments conforming to DIN 41494 (General industria lstandard for equipments) B Make- D-Link/Schneider/Dynamic complete in all respect with the prior approval of Engineering In Charge. |
| 3 | Supply and Installation: 4X4 Access Point Physical Interfaces : One 100/1000/2.5GBASE-T Gigabit Ethernet (RJ-45) ports with Auto Uplink (Auto MDI-X) supporting IEEE 802.3af or 802.3at Power over Ethernet (PoE),Two (2) Internal 3.1/4.3 dBi (2.4GHz/5GHz) antenna ,Four (4) LED: Power and Cloud connection; LAN speed; 2.4GHz status; 5.0GHz status,Power adapter (not included): 12V DC, 2.5A. Standards : 5.0GHz: 802.11a/n/ac/ax; 2.4GHz: 802.11b/g/n/ax , IEEE 802.11ax WiFi 6 standard , WMM - Wireless MultiMedia Prioritization , WDS- Wireless Distribution System , Power over Ethernet (PoE) IEEE 802.3af/802.3at. Security: Wi-Fi Protected Access (WPA, WPA2, WPA3), 802.11i, WPA2 Enterprise , Wireless access control to identify authorized wireless network devices , MAC address filtering with access control , 802.1x RADIUS support with EAP TLS, TTLS, PEAP, Neighbor AP detection, VLAN Support, Secure Socket Layer (SSL), Guest Network/Captive Portal, Bandwidth management, Link Layer Discovery Protocol. Network Management : Cloud based App Management for setup, monitoring and management from anywhere anytime (Remote configuration and management), Easy-to-use Web browser-based management GUI, Manageability : As standalone, Centralized Management through Mobile Application. Advanced Wireless Features : Wireless Distribution System (WDS), Bridge mode: Point-to-point wireless WDS mode, Bridge mode: Point-to-multipoint wireless WDS mode, Repeater mode,Adjustable Transmit Power Control (TPC), Device detection, Identify type of wireless clients in the network. Other Specifications : PoE power consumption: 25.5W, Business class WiFi based on next generation 802.11ax WiFi 6 technology on both 5.0GHz and 2.4GHz bands. Backward compatible to 802.11b/g/n/a/ac, Dual band 4x4 (2.4GHz and 5.0GHz) 8 streams of data for an aggregate throughput of up to 3.6Gbps, Theoretical Throughput per Band: 5.0GHz: 2400Mbps; 2.4GHz: 1200Mbps, Orthogonal Frequency Division Multiple Access (OFDMA), Multi-Gigabit Support, Target Wake Time (TWT), Basic Service Set Coloring (BSS Coloring), Bandsteering, Block SSID Broadcast, Ceiling mounting / Wall mounting, Bidir and MU-MIMO support. Warranty and Support : , 3 Years Centralized Management license included, 5 Years free latest firmware support, Rs. Make- Cisco/Netgear/Ruckus complete in all respect with the prior approval of Engineering In Charge. |
| 4 | Supply and Installation: Supports up to 8 10/100/1000Mbps Gigabit Ethernet PoE ports and 4 SFP slots, IEEE 802.3af/at PoE compliant to simplify deployment andSupports PoE up to 30W per port with 140W total power budget. 8 10/100/1000 Base-T Ethernet PoE Ports 4 Gigabit Combo (RJ-45/SFP) Ports Reset Button: reset to default setting, Switching Capability: 24Gbps MAC Address Table: 8K PoE Power Budget: 140W Packet buffer size: 4.1MB Jumbo Frame: 10K. L2 Features Auto-negotiation for port speed and duplex mode Spanning Tree Protocol-Support STP / RSTP / MSTP (max 16 instance)-Loopback Detection- BPDU Filter- BPDU Guard, LLDP IGMP v2/v3 Snooping: IGMP Querier, Immediate Leave MVR VLANs - 256 IEEE 802.1q tag based VLAN with 4K VLAN ID - MAC Based VLAN, Voice VLAN, Guest VLAN, Management VLAN Link Aggregation- LACP: 8 Groups, 8 Ports/Group-Static Trunk. Queueing Mechanism: SP and WRR Classifications based on- COS, COS DSCP, IP Precendence, Each port supports 8 queues Rate Limit (Port Based): Ingress/ Egress Port Flow Control.MAC address Binding Support Broadcast/Multicast/Unicast storm control IP and MAC ACL (Ipv4) RADIUS, 802.1x based Authentication Port Security, Protected Port Management ACL DHCP Snooping, DHCP Snooping option 82, IP Source Guard, IP-MAC-Port-VLAN Binding. Management Port Mirroring Support traffic statistics, FAN less design, Provide IPv4 Web-based management IPv4 DHCP Client Configuration Backup and Recovery Dual firmware images and Configuration files Error Disabled, Bandwidth Utilization, SNMP v1/v2c/v3 C11 Remote Server Telnet, SSH,HTTP, HHTPS RMON, SNTP Ping, Traceroute EEE, Port Statistics. 330(W) x 230(D) x 44(H) mm, AC Power: 100 to 240 V, 50-60 Hz, Input Surge Protector. IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.3ab 1000BASE-T, IEEE 802.3az IEEE, IEEE 802.3at & IEEE 802.3af. Temperature : Operating: 0°C ~ 40°CStorage: -40°C ~ 70°C Humidity: perating: 10% ~ 90% RH (Non-condensing) Storage: 5% ~ 90% RH (Non-condensing) Display Each port have a dedicated LED status display. Link/Act Hardware Factory Reset button. Traffic on a port can be mirrored to another port for analysis with a network analyzer. . Make- Cisco/Digisol/Juniper complete in all respect with the prior approval of Engineering In Charge. |
| 5 | Supply and Installation: CategoryPatch Panel should be 24 Port 1U Size loaded with 24 port RJ-45 IO/Jack,Mounts in standard 19 inch racks,Patch panel should have rear cable manager for improvement management,Patch panel suitable for Category 6 keystone,Panel material should have SPCC with 1.5mm thickness and Black Color,Support bar material should have SPCC with 1.5mm thickness and Black Color,RJ-45 jack housing should be PBT + Glass fiber UL94V-O and Contact brackets should be PBT + Glass fiber UL94V-O,Rj-45 contact material should be phosphor bronze with nickel plated and plug contact area finish with 50 micro-inches Gold plated, Rj-45 jack life should be 700 times minimum,Operating temperature should be -10° Celsius to 60° Celsius.Make- D-Link/Molex/Commscope complete in all respect with the prior approval of Engineering In Charge. |
| 6 | Supply and Installation: Category 6 patch cords 1 /2 Mtr with four pair twisted cable terminated with RJ45 modular plugs at both the ends,Patch Cord should have TIA/EIA 568C.2 standard.,Shall be backward compatible with Category 5 and Category 5e systems, Category 6 patch cord should be 100% factory made and performance tested,Category 6 patch cord length requires – 2 meter/ 1 meter,Color code for Patch Cord: Grey,Performance Characteristics ,Patch cord conductor should be 24 AWG, multi-strands ,Patch core conductor metal should be made from bare copper,Insulation material should be high density polyethylene,Patch cord jacket should be LSZH,Modular Connector/Plug Characteristics,Patch cord plug should be gold plated,Contact blade of plug should be made from copper / alloy,Insertion cycle should be 750 times,Temperature range should support from 10° Celsius to 60° Celsius.. Make- D-Link/Digisol/Commscope complete in all respect with the prior approval of Engineering In Charge. |
| 7 | Supply and Installation: Category 6 keystone jacks are RJ45, 8 position 8 contact socket. Category 6 keystone jacks are suitable for 22-26 AWG stranded and solid wire. Keystone jacks are compatible with both 110 & Krone punch down tools. The Category 6 keystone jacks shall be backward compatible with Category 5e, 5 and 3 cords and cables. It compliance with ANSI/TIA/EIA 568 C.2 standard. The Category 6 keystone jacks shall be of a universal design supporting T568 A & B wiring. Color of Keystone Jack: White Category 6 keystone jacks housing made from PC, UL 94V-2 material. RJ45 Jack contact material should be phosphor bronze with nickel plated. Finished with 50 micro-inch gold plated on plug contact area. IDC Housing made from PC, UL 94V-2. Terminal material should be Phosphor bronze with tin plated. Should have IDC CAP and material of IDC Cap should be PC, UL 94V-2. Current rating should be 1.5A. Life of Jack should be 750 cycles minimum (ISO/IEC 11801/IEC 60603-7-4). Operating Temperature should be -10° Celsius to 60° Celsius.Make- D-Link/Commscope/Belden .Supply and Installation: Face plate should be single port with Back box. Face Plate should have shutter to protect from dust. It should have write on labels in transparent plastic window – supplied with plate. Face plate material: ABS with white color. Screw should be supplied with face plate Make- D-Link/Commscope/ Molex complete in all respect with the prior approval of Engineering In Charge. |
| 8 | Supply & Installlation: of Heavy Duty Floor race way(19L*9w*CM) Make- Tarkas/Serplex/Dolphy complete in all respect with the prior approval of EIC. |
| 9 | Supply and Installation: RJ 45 Connector Box, Housing: PC, UL94V-2, transparent color, Contact Terminal: Copper Alloy, Finished: 03MU micro-inch gold plating, Use for 24-26 AWG stranded wires, meet wiring scheme T568A/T568B, RJ 45 connector with installation with prior approval from EIC. Make- D-Link/Digisol/Commscope complete in all respect with the prior approval of Engineering In Charge. |
| 10 | Supply,Laying & Testing: 3*1.5 sqmm wire (3 pair cable), Flame Retardent(FR), Multistrand. Make- Polycab/Havells/KEI complete in all respect with the prior approval of Engineering In Charge. |
| 11 | Providing of 4 Sqmm 4 core copper cable Unarround Make- Polycab/Havells/KEIcomplete in all respect with the prior approval of Engineering In Charge. |
| 12 | Supply and laying Flexible Pipe 25/32mm for Data and electrc wire laying complete in all respect with the prior approval of Engineering In Charge. |