| 1 | Taking downcarefully Copper/aluminium point wiring on wooden batten /pvc conduit /Pvc casing and capping (light/Socket/Power) complete including (Fittings such as switches, ceiling roses, pendants, regulators, sockets electric energy meters, light fittings,etcto be measured separately) removing materials to store and making good distrubed surfaces of walls. Floors etc to match with the existingincluding disconnection of ceiling/exhaust fan connection, complete all as specifed and directed by Engr-in charge. |
| 2 | Taking out existing sub main wiring of any description and size including earth wire incld wooden battens/ conduits/quities from stone/brick masonry walls, roofs, floors, etc, complete all as specifed and directed by Engr-in charge. |
| 3 | M&L in replacement of point wiring complete with 1.5 sqmm (nominal area) PVC insulated unsheathed multistranded copper condutor single core cable 1100 volts grade FRLSH ISI marked drawn through and incl non metalic PVC conduit, ISI marked of not less than 20 mm dia, heavy duty, concealed in wall, roof, etc, with all connected fittingsMODULAR WHITE COVER PLATE WITH FRAME - 1 module/ 2 module/3 module/4 module/6 module/8 module/12 module, etc., MODULAR METAL FLUSH BOX - 1 module/ 2 module/3 module/4 module/6 module/8 module/12 module, etc., and including FRLSH PVC insulated unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:-Note:- modular switches, sockets, ceiling rose, regulators, white plate etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting conduit and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall. |
| 4 | One light/fan/Bell point controlled by one switch, complete all as specifed and directed by Engr-in charge. |
| 5 | One lightpoint controlled by two way switch, complete all as specifed and directed by Engr-in charge. |
| 6 | One 3 pin socket outlet independent 5 Amps, complete all as specifed and directed by Engr-in charge. |
| 7 | One socket outlet 5 Amps on the same board with other switches, complete all as specifed and directed by Engr-in charge. |
| 8 | One 6 pin 5/15 Amps socket outlet independent with 2.5 Sqmm size copper conductor cable and2.5 sqmm copper cables as earth wire, complete all as specifed and directed by Engr-in charge. |
| 9 | M&L in replacement of Point wiring complete with 1.5 sqmm (nominal area) PVC insulated unsheathed multistranded copper condutor single core cable 1100 volts grade FRLSH ISI marked drawn through existingnon metalic PVC / steel conduit,with all connected fittingsMODULAR WHITE COVER PLATE WITH FRAME - 1 module/ 2 module/3 module/4 module/6 module/8 module/12 module, etc., MODULAR METAL FLUSH BOX - 1 module/ 2 module/3 module/4 module/6 module/8 module/12 module, etc., and including FRLSH PVC insulated unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:-Note:- modular switches, sockets, ceiling rose, regulators, white cover plate etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for during excuition of work and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall. |
| 10 | One light/fan/Bell point controlled by one switch, complete all as specifed and directed by Engr-in charge. |
| 11 | One lightpoint controlled by two way switch, complete all as specifed and directed by Engr-in charge. |
| 12 | One 3 pin socket outlet independent 5 Amps, complete all as specifed and directed by Engr-in charge. |
| 13 | One socket outlet 5 Amps on the same board with other switches, complete all as specifed and directed by Engr-in charge. |
| 14 | One 6 pin 5/15 Amps socket outlet independent with 2.5 Sqmm size copper conductor cable and2.5 sqmm copper cables as earth wire, complete all as specifed and directed by Engr-in charge. |
| 15 | M&L in replacement of Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4 sqmm (line conductor) & 1x 4 sq mm (earth conductor), 1100 V grade drawing in & including heavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10cm grith complete all as specified and directed.Note : (i)Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 16 | All as per ser item No. 5.00 here-in-befour but inPVC conduit with single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x1.5sqmm and 1 x 1.5 sqmm, complete all as specifed and directed by Engr-in charge. |
| 17 | All as per ser item No 5.00 here-in-befour but inPVC conduit with single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x2.5sqmm and 1 x 2.5 sqmm, complete all as specifed and directed by Engr-in charge. |
| 18 | M&L in replacement of Sub main wiring with 5 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 4x6 sqmm (line conductor) & 1x 6 sq mm (earth conductor), 1100 V grade drawing in & existingnon metalic PVC / steel conduit, , ISI marked, incl accessories not less than 25 mm in dia & existing concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed.Note : (i)Four runs of copper conductor cable and one run of copper earth wire will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 19 | All as per ser item No 8.00here-in-befour but in existingPVC / steel conduit with single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 4x4 sqmm and 1 x 4 sqmm, complete all as specifed and directed by Engr-in charge. |
| 20 | S&FModular switch 1 way 6 A, 1 module type single pole 240 volts, complete all as specifed and directed by Engr-in charge. |
| 21 | S&F Modular switch 2 way 6 A, 1 module type single pole 240 volts, complete all as specifed and directed by Engr-in charge. |
| 22 | S&F Modular socket 6 Amps 2/3 pin combined 2 module240 Volts, complete all as specifed and directed by Engr-in charge. |
| 23 | S&FModular socket 16Amps 2/3 pin combined 2 module240 Volts, complete all as specifed and directed by Engr-in charge. |
| 24 | S&FModular switch 16Amps 2/3 pin combined 1 module240 Volts, complete all as specifed and directed by Engr-in charge. |
| 25 | S&F Modular bell push 6 Amps 1 Modules 240 Volts, complete all as specified and directed by Engr in -Charge. |
| 26 | M&L in replacement multi music type bell ding dong AC, 230 V single pole, complete all as specifed and directed by Engr-in charge. |
| 27 | Taking down ceiling fan / Exhaust Fan and connected cables removing it to safe place and Re-Fixing ceiling fan and connecting up including provision of cable from ceiling rose to fan, complete all as specified and directed by Engr-in-charge. |
| 28 | S&F modular fan step regulator, 120 w-1/2 module 240 volts, complete all as specified and directed by Engr-in-charge. |
| 29 | S&Fwhite cover plate with frame 1 module 240 volts, complete all as specified and directed by Engr-in-charge. |
| 30 | S&Fwhite cover plate with frame 2 module 240 volts, complete all as specified and directed by Engr-in-charge. |
| 31 | S&Fwhite cover plate with frame 3 module 240 volts complete all as specified and directed by the Engr-in-charge. |
| 32 | S&Fwhite cover plate with frame 4 module 240 volts, complete all as specified and directed by Engr-in-charge. |
| 33 | S&F white cover plate with frame 6 module 240 volts, complete all as specified and directed byEngr-in-charge. |
| 34 | S&F white cover plate with frame 8 module 240 volts, complete all as specified and directed by Engr-in-charge. |
| 35 | S&F white cover plate with frame 12 module 240 volts, complete all as specified and directed by Engr-in-charge. |
| 36 | S&F modular metal box 1/2 module, complete all as specified and directed by Engr-in-charge. |
| 37 | S&F modular metal box 3 module, complete all as specified and directed by Engr-in-charge. |
| 38 | S&F modular metal box 4 module, complete all as specified and directed by Engr-in-charge. |
| 39 | S&F modular metal box 6 module, complete all as specified and directed by Engr-in-charge. |
| 40 | S&Fmodular metal box 8 module, complete all as specified and directed by Engr-in-charge. |
| 41 | S&F modular metal box 12 module, complete all as specified and directed by Engr-in-charge. |
| 42 | S&F in repair switch piano flush type 5/6 Amps single pole one way, complete all as specified and directed. |
| 43 | S&F in repair switch piano flush type 15/16 Amps single pole one way, complete all as specified and directed. |
| 44 | M&L in repair for socket out let 3 pin 5/6 Amps flush type, complete all as specified and directed. |
| 45 | M&L in repair for socket out let 3 pin 15/16 Amps, complete all as specified and directed. |
| 46 | Supply onlyswitch socket combination with PVC module box 5A/16A, 5 in 1 flush type, complete all as specified and directed. |
| 47 | S&F in repair modular switch type 5/6 single pole one way as existing, complete all as specified and directed. |
| 48 | S&F in repair modular socket out let 3 Pin 5/6 Amps as existing, complete all as specified and directed |
| 49 | S&F in repair modular switch type 15/16 Amps single pole one way as existing, complete all as specified and directed. |
| 50 | S&F in repair modular socket out let 3 Pin 15/16 Amps as existing, complete all as specified and directed. |
| 51 | S&Fin replacement ceiling rose bakelite, 63.5mm3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-charge. |
| 52 | S&F inreplacement round LED 15 Watt (colourcool white/Neutral white/warm white)downlighter / LED ceiling light / slim light for home and hall / surface mounted,cut out 140mm, making good disturbed surface of area to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 53 | S&F in replacement round LED 9 Watt (colourcool white/Neutral white/warm white)downlighter / LED ceiling light / slim light for home and hall / surface mounted,cut out 140mm, making good disturbed surface of area to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 54 | S&F in replacenment modular angle holderwithinsulated body with back plate for LED lamps, complete all as specified and directed. |
| 55 | S&F in replacement LED lamp 9 watt, retrofit, complete all as specified and directed. |
| 56 | S&F in replacement bulk headLED 10W, colour natural white / cool white, 20000 burning hours, dust ans waterproof,IP -65 rating product, speak design with unbreakable polycarbonate diffuser 230 V, complete all as specified and directed. |
| 57 | S&F in replacement mirror light fitting LED 10W, 230 V, 2ft, complete all as specified and directed by Engr-in-Charge. |
| 58 | S&F in replacement LEDtube light fittings 1 x 20 W, 230V, 4 ft, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose complete all as specified and directed by Engr-In- Charge. |
| 59 | S&F in repair sheet metal enclosure SPN 20 Amps earth plugsocket top,complete all as specified and direced by Engr-in- Charge. |
| 60 | S&F inreplacement only rigid non meatalic PVC conduit heavy duty 25mm dia ISI marked with all accessories and fittings on surface of wall, ceiling and making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 61 | S&F in repair LED building security light, pressure die cast aluminium housing, 15 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. of a bracket made out of 1.5 mtr long Medium grade GI pipe as per suitable dia bend to shape as directed fitted on wall at a height not less than 6 mtr from groundwith MS clamps, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire, complete all as directed and specified by Engr-in-charge. Note:- Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. |
| 62 | S&F inreplacement LED Flat panel 34W / recess mounted and PMMA diffuser makes it a robust lumininaireand making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 63 | S&F in replacement inverted white iron spot & track light water proof type (Indoor and outdoor type) fixture made up of polycarbonate for LED3W IP 65,rotation/angle 38 degree and making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 64 | M&L for earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc., complete all as specified and directed by Engr-in-Charge. |
| 65 | S&F in replacement decorative wall light fixture made up of aluminium housingfor 09 W and making good disturbed surface of wall to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 66 | Material & LayingXLPE insulated,strip armoured heavy duty electric multistranded aluminium conductor cable in repair1100 volts , 4 core 16 Sqmm including taking down existing unsv service cable, complete all as specified and directed by Engr-in-charge. |
| 67 | Material & LayingXLPE insulated,strip armoured heavy duty electric multistranded aluminium conductor cable in repair1100 volts , 2 core 16 Sqmm including taking down existing unsv service cable, complete all as specified and directed by Engr-in-charge. |
| 68 | Material & LayingXLPE insulated,strip armoured heavy duty electric multistranded aluminium conductor cable in repair1100 volts , 2 core 10 Sqmm including taking down existing unsv service cable, complete all as specified and directed by Engr-in-charge. |
| 69 | Excavation in trenches in soft/loose soil not exc 1.5m wide and not exc1.5m deep and getting out including forming bottom surfaces to required level or slope for taking out embeded cables, brick/PCCprotective tiles,complete allspecified and as directed by Engineer-in-Charge. |
| 70 | M&L sand cushioning (drysand) to under ground cable for cable protection provided with layers 8cm deep before layingand 15cm after laying the cable, complete all as specified and directed.Note :- Punned thickness will be measured only. |
| 71 | M&L laying in trenches as cable protection cover class LV, type I, flat size 250mm x 150mm x 40mm,ISI marked, complete all as specified and directed. |
| 72 | Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level not exc 50 m above the starting point, complete all as specified and directed. |
| 73 | Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer, complete all as specified and directed. |
| 74 | S&F40mm dialight grade,galvanised pipe with all fitting laid in trenches/ passing through roads alongwith cutting and making surface good with existing surface including taking down old GI tube, complete all as specified and directed by Engr-in-charge. |
| 75 | S&F in repair sheet metal enclosure DB verticalTPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 415V, 4 way with shrouded neutral bar, earth bar and including cable ties and suitable size blanks, including taking down of existing sheet metal enclosure, complete all as specified and directedNote:- (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate.(b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 76 | S&F in replacement thermal magnetic adjustable type MCCB 63 Amps ,16 KA, \"C\" series 415. V ISI marked. complete all as specified and directed by Engr-in-Charge. |
| 77 | S&F in repair sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V,12 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure, complete all as specified and directed. |
| 78 | S&F in repair sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 8 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure, complete all as specified and directed. |
| 79 | S&F in repair sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V,4 way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure, complete all as specified and directed.Note for ser item Nos 66 to 68 - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate.(b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 80 | S&F in replacementMCBSP 6 -32 Amps,10 KA, \"C\" series 240 V ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 81 | S&F in replacement MCB SPN 32 Amps,10 KA \"C\" series 240 V ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F in9 Watt motion sensor based LED Bulb for offices, complete all as specified and directed by Engr-in-Charge. |