}

Renovation Work Of Electrical Installations, Air-Conditioning System, Fda Systems At Dsa Cathlab At Bin Old Building, Bin, Annex I, Ipgme And R Sskmh.(Electrical Work)-Renovation Of Air-Conditioning System At Dsa Cathlab., kolkata-West Bengal

Public Works Department has published Renovation Work Of Electrical Installations, Air-Conditioning System, Fda Systems At Dsa Cathlab At Bin Old Building, Bin, Annex I, Ipgme And R Sskmh.(Electrical Work)-Renovation Of Air-Conditioning System At Dsa Cathlab.. Submission Date for this Tender is 10-10-2025. Air Conditioner Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

51204799
Renovation Work Of Electrical Installations, Air-Conditioning System, Fda Systems At Dsa Cathlab At Bin Old Building, Bin, Annex I, Ipgme And R Sskmh.(Electrical Work)-Renovation Of Air-Conditioning System At Dsa Cathlab.
Tender
Indian
West Bengal
Kolkata
10-10-2025
BootCamp

Tender Details

Renovation Work Of Electrical Installations, Air-conditioning System, Fda Systems At Dsa Cathlab At Bin Old Building, Bin, Annex I, Ipgme And R Sskmh.(Electrical Work)-Renovation Of Air-Conditioning System At Dsa Cathlab.- 1 S&D of minimum 7KW nominal cooling capacityceiling suspended [ concealed]Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make :O General model ARG25FUAN/AOG25FNANL/ Similar of Mitsubishi Electric / Mitsubishi heavy industries). 2 S&D of minimum 13KW nominal cooling capacityceiling suspended [ concealed]Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/ RZMF140BRY16 / Mitsubishi heavy industries model FDUM125CSV-S6/FDC125CSV-S6 / O General model ARG60F/AOG60F). 3 Installation testing & commissioning of above AC machines by fixing the indoor with adequateMS angle supports sized 50mmX5mm with 10mm X75mm anchor fastner bolt drilled into the ceiling and grouted into the wall . The indoor unit suspended from thissupport with4 nos10mm full threaded suspender bolt with double nut & spring washer.Out door unit will be fixed after making suitable MS structure platform with 50x5mm MS angle support grouted into the wall with cross arm support. Grill support at top and both sides to be made with suitable size angles and MS flats and locking arrangement. A shet at top the outdoor unit also to be made with corrugated GI sheet to avoid damage from top. The job to be done considering all civil works and mending good the damages of walls by CC & sand cement plaster . All MS works need to be finished with primer and paints and executed as per the direction of EIC. 4 REFRIGERANT PIPING: Supplying, laying and commissioning of hard copper refrigerant piping (minimum thickness 0.9 mm), complete with fittings, elbows, supporting arrangements etc.with Nitrile Rubber tube insulation of 9 mm thick on Copper Pipe. (Make- K-Flex/Armacell) 5 Discharge Line 6mm dia, min. thickness 0.8mm (Make : Rajco / Royku/Nippon). 6 Discharge Line 9.5mm dia, min. thickness 0.8mm (Make : Rajco / Royku/Nippon). 7 SuctionLine15.88mm dia,min.thickness 0.99mm(Make : Rajco / Royku/Nippon). 8 SuctionLine19.05mm dia,min.thickness 0.99mm(Make : Rajco / Royku/Nippon). 9 CONDENSATE DRAIN PIPING: Supplying & laying of 25 mm dia (SCHEDULE 40) Drain Water piping work out of PVC / HDPE hared pipes, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors with insulation. (Make - Supreme/Finolex/Prince Pipe) 10 CONTROL CABLING: Supply & Laying of 6 Core 2.5 sq.mm.unarmoured Cu control cable. 1.1 KV Gr. PVC/XLPE insulated, PVC- Sheathed cable, Copper armoured for Control cable incl.laying on wall surface by suitable clamping arrangement, proper glanding & finishing the cable ends with solderless sockets for following cables. (Make - Polycab/Havells/Finolex ) 11 Charges for suspended false ceiling to cover the Indoor Units & Supply air duct including the cost of hinged type trap door arrangement with 3mm thick ACP Sheet as per manufacturers specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (2mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm x 38mm (2mm thick) and silicon sealent complete in all respect as per direction of EIC. (Make: Armstrong/Aludecor) 12 Supply & Fixing of Canvas for concealed split unit. 13 Supply & fixing of extruded Aluminium Grill (Make - Caryaire/Ravistar/Dynacraft). 14 S& charging R410refrigerant 15 Supply, design, fabrication, installation of MS structural work with different sizes c-channel, equal angles and flats for outdoor supports as per site requirement. (As per direction of EIC) 16 SITC of FactorydesignedCeiling Suspended Air HandlingUnit with0.6 mm pre coatedGI (outside) & 0.6mm plain GI (inside)doubleskin casing having 25mmthickPUF insulation (38kg/cum), 6 rowdeepchilledwatertype coolingcoil,DIDW backwardcurvedcentrifugal fanwithhighefficiency motor, synthetic pre-filter 90% down to 10 micron 18 SWG SS drain tray and all otheraccessories completeas per specificationfor the following capacity. The AHU shall consist of 1 no. Centrifugal Blower with 2 nos.(1W + 1S) TEFC Squirell cage inductionmotor. The AHU shall be completewith VFD.The VFD shall be of IP20 rating. AHU MAKE- Edgetech / Zeco / Caryaire & VFD MAKE - ABB / Danfoss / Siemens 17 5500 CFM Nominal Capacity, 50 MM TSP ( DSA Corridor, Recovery & Store Room, UPS Room, Consultant Room) 18 Installation charges of the above CSU after making suitable platform with S&F of 2 nosC channel size not less than 75x50x10mm at top and 50x5 mm MS angle at bottom for rigid support with primer and painting work. Allied civil and allignment work also taken to the consideration , mending good upto final finishing . 19 SITC and insulating of followingnominal sizes chilled water piping complete withfittings,supports,bends,elbows,flanges,insulationets. with necessary supporting arrangement from wall/ceiling with MS angle, clamps, vibration isolators and fittings duly insulated SITC of following THERMAL INSULATION OF CHILLED WATER PIPE with 25 MM THICK Nitrilerubberwith24SWG aluminiumsheet clading. The pipes shall be of MSERW, C or Heavy class as per IS 1239 and IS 3589 standards (for pipe sizes above 150 mm NB) (as per direction of EIC)MAKE OF PIPE: TATA/JINDAL, MAKE OF INSULATION: ASTHA/BEARDSELL 20 80mm NB 21 65mm NB 22 50mm NB 23 BUTTERFLY VALVES&F of the following Water line Butterfly-Valve as per following categories, sizes and qunatities complete with providing flanges, nut-bolts, gasket and welding arrangements: Butterfly valve shall be of PN 16 rating as per standard. Valves of sizes 32 mm and above shall be made out of Cast Iron body, SG iron disc with Nylon coated, SS-431 Stem, EPDM integrally moulded liner with hand lever/Gear Box. Valves up to 150 mm NB shall be with detachable hand lever operation whereas valves above 150 mm NB shall have warm gear operation. (Make - Advance / Audco/Honeyell). 24 100mm 25 80mm 26 50mm 27 S & F of the following Water line Balancing - Valve as per following categories, sizes and qunatities complete with providing flanges, nut-bolts, gasket and welding arrangements:The valves shall be designed for PN 16 rating as per standard. The valves of sizes 32 mm to 65mm dia. shall be of gun metal / cast iron construction with screwed ends angular design hand wheel with locking facility. Whereas valves of sizes 80mm and above shall be of cast iron construction with internal parts of SS 410 and EPDM / nitrile seat with flanged ends. The test cocks should be long enough to protrude out of valve insulation (Make - Advance / Audco / Honeyell ). 28 50mm 29 SITC of 3-WAY Modulating Valve suitable for operation with a signal of 0-24 volt DC,WITH ACTUATOR, LINKAGE & THERMOSTAT in chilled water line to the cooling coil of AHU actuated by a proportionate thermostat. The valve shall consist of bronze metal body with stainless steel trim. The pressure drop across valve shall not exceed 5.0 PSI. The valve linkages shall be of the same make as of valves & modulating motor. (Make- Danfoss /Jhonson /Honeywell /Siemens) 30 40mm 31 S & F of the following Water line PRESSURE GAUGE as per following categories,sizesandqunatitiescompletewithprovidingflanges,nut-bolts, gasketandweldingarrangements. Bourden type pressure gauges of100mm dia ofsuitablerange shall beprovided.The waterpressuregaugeshallbemadeofstainlesssteelgradeSS304.Thedial plate shall be powder coated with white colour base & the calibration shall be doneinblackcolour.Allthepressuregaugesshallbecompletewithball valves & SS Siphon and confirming to IS:3624.[ MAKE: H GURU /WAREE / FIEBIG] 32 SITCofthefollowingWaterlineINDUSTRIALTYPETHERMOMETER,as per followingcategories,sizesandqunatitiescompletewithprovidingallfixing accessories:TheVformthermometershallbe madeofaluminium diecastingwithgoldencolouranodizing.ThethermometershallhaveaV groove in the body to protect the refill from the damages during the installation. The refill shall be filled with blue colourmercury. The thermometer shall be complete with brass well & the calibration of temperature shall be in Celsius & Fahrenheit.[ MAKE: H GURU/ WAREE / FIEBIG]. 33 SITC of ball valve as per site requirement. (Make- Advance / Leader / Zoloto) 34 25mm 35 SITC of GI DUCT of Class - VIII gradefor supply/return air duct along with pre fabricated plenum for supply and return air with necessary supports, flanges etc. as required and as per IS 655 and IS-277 standards of following gauges. (Make - Sail/Tata) 36 24 SWG thick 37 22 SWG thick 38 20 SWG thick 39 Supplying & fixing of 19 mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation. (Make - Armacell / K Flex) 40 Supplying & fixing of acoustic insulation inside ducting with 10mm thick open cell nitrile rubber(class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required. (Make - Armacell) 41 SITC of Drain piping with schedule 40 PVC pipes with fittings duly insulated with with 25 MM THICK Nitrile rubber .Make - Armaell / KFlexalong with necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc: (MAKE - Finolex / Supreme ) 42 32 mm 43 SITC of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring. The damper shall be motorized and spring return so as to the damper in the event of power failure automatically and open the same in case of power being restored The spring return action shall be inbuilt mechanism and not external mounted The damper shall also be closed in the event of fire signal complete as required and as per specifications 44 Motorised Fire damper 45 Actuator with motor drive 46 Supply and fixing of Flexible double Canvas connection in between each AHU andSupply/ReturnAir Duct.(CustomMakeor Asper direction of EIC) 47 Supply & Fixing of Aluminium powder coated supply air diffusers/grilles with volume control damper (Make - Systemair / Air Enterprise / Premire / Caryaire / Airmaster) 48 Supply & Fixing of Aluminium powder coated return air diffusers/grilles without volume control damper (Make - Systemair / Air Enterprise / Premire / Caryaire / Airmaster) 49 S & providingdrop ceiling to cover the indoor units & supply air duct including the cost of3mm thick ACP sheet as per manufacturers specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (2mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm x 38mm (2mm thick) and silicon sealent complete in all respect as per direction of EIC. (Make:Aludecor/Armstrong) 50 SITC of wallmounted cubicaltype LTcontrol panel & VFD Bypass Starter Electrical Panel Board fabricated from sheetsteel comprisingwith following accessoriesincl.internalwiringearthing& painting. (ForotherthanOT areas). (Make- EAP/Genpower/ CPRI Approved Vendor)i)MCB of suitableratingas incomer& MCBs as outgoing as per the rating of AHU motor .ii)DOL / SD starter as per HP ratings.--2 nosiii)VFDStarter as per HP ratingsiv)Terminal block for power distribution.v)Contactor, auxilary contractor, over load relay, Phase sequence & single phasing preventer.vi)Phase indicating lights andindicating light for ON , OFF & TRIP status.vii) Wiringfor microswitch for stopping thefan when fire damper closes.viii) Panelmounted3phase digitalAmmeter- 1 noix)One no 24V DCRelay forinter connection with Fire Detection system.x)24V AC & 24V DC of 1A capacity for operation of fire damper & fire relay.xi)Danger Board. 51 Supply, installation, testing and commissioning of sound attenuators in supply & return air / exhaust ducts Note : The length of all sound attenuators shall be minimum 1200 – 1500 mm to be based on insertion loss requirements as indicated in specification. 52 Supply, installing, testing and commissioning of air curtains. The unit shall be made from 20 SWG cold rolled MS sheets duly powder coated. Blower shall be of high quality Aluminium/ ABS plastic statically & dynamically balanced with low noise (< 72 dB & vibration). Quoted price shall also include cost of limit swirch, power wiring, control wiring and earthing. The unit capacities shall be as follows: 53 1500 mm wide for Door height 3.0 meter (10 feet) 54 Less Cost of 06 (six) nos old air-conditioning machines aged more than 10 years, along with piping and other accessories @Rs. 30000/- 55 The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules 56 Defect Liability Period - 1 (One) year 57 Make & model of each and every material to be approved by EIC

Key Value

Document Fees
Refer document
Tender Value
INR 17.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail