| 1 | (A) FIRST FLOOR |
| 2 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 3 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 4 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level/Above Plinth level. |
| 5 | ( b ) Tor steel bars. |
| 6 | Centering & shutteringincluding strutting , propping etc and removal of form for |
| 7 | (b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 8 | (d) Lintel , beams , plinth beams , girder , bressumers and cantilever with water proof ply 12mm thick |
| 9 | (b) Suspended floor , roof , landing, balconies ans access platform with water proof ply 12mm thick |
| 10 | (e)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 11 | (f) Stair ( excluding landing s) except spiral - staircases |
| 12 | Half brick masonry with 1st class common burnt burnt clay FPS in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 cement : 4 Kanaighat coarse sand) |
| 13 | Brick work with Ist class common burnt clay F.P.S.(non modular)bricks in superstructure above plinth level upto floor V level in all shapes and sizes in :(i)cement mortar 1:4 (1 cement : 4Kanhaighatcoarse sand) |
| 14 | Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately 9.1.3. Local best quality Tolhao wood |
| 15 | P/F panelled, glazed or panelled & glazed shutters for doors, windows and clerestory windows i/cISI marked MS butthinges bright finishedof required size with necessary screws excluding panelling which will be paid separately , all complete as per direction of Engineer in charge (b)Local best quality Tolhaowood 35 mm thick shutters |
| 16 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality Tolhao wood |
| 17 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws..(a) Local best quality Tolhao wood.(35mm thick). |
| 18 | Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts andwooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand:6 graded stone aggrt.) |
| 19 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm |
| 20 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (a) 250x10 mm |
| 21 | (b) 100x10 mm |
| 22 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. (a) 125mm |
| 23 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 24 | Providing & fixing M.S. grills of required pattern to wooden frames vertically andhorizontally with M.S. flats at required spacing & frames basedon Architecturaldrawing ..i/cpriming,painting etc.Complete as per direction ofEngineer-in-Charge. |
| 25 | Marble stone flooring in treads of steps and risers using single length upto 2.00 metre with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality. |
| 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 Kanhaighat coarse sand) including grouting the joints with white cement and matching pigments etc., complete.(a) Double charge vitrified tile polished finish of size (i) Size of Tile 600x600 mm |
| 27 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 Kanhaighat coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete (i) 8mm thick |
| 28 | Providing and laying Ceramic glazes floor tiles 300 X 300 mm (thickness to be specified by the manufacturer ) of 1st quality conforming to IS : 15622 of approved make in colour such as white, ivory. grey, fume. red, brown laid on 20 mm thick cement mortar 1 : 4 ( 1 cement: 4 Kanhaighat coarse sand ) including pointing the joints with white cement and matching pigment etc complete . |
| 29 | Providing and fixing 1sy quality Ceramic glazed wall tiles conforming to IS : 15622 300 X 300 mm (thickness to be specified by the manufacturer ) of approved make in all colours shades except burgundy, bottle green,black,skirting risers of steps and dados over 12 mm thick bed of cement mortar 1 : 3 ( 1 cement: 3 Kanhaighat coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete . |
| 30 | Providing and laying pressed claytiles (as per approved pattern 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4(1 cement :4 coarse sand)mixed with 2% integral water proofing compound,laid over a bed of 20mm thick cement mortar 1:4(1 cement:4coarse sand) and finished neat complete. |
| 31 | 12mm cement plaster of mix1:4 (1 cement : 4 Kanaighat coarse sand). |
| 32 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 coarse sand). |
| 33 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer |
| 34 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 35 | Finishing wall with acrylic smooth exterior paint of required shade :- new work (two or more coats applied @ 1.67 ltr / 10 sqm over and i/c base coat of water proofing cement paint applied @2.20 kg / 10 sqm. |
| 36 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade (i) Two or more coats |
| 37 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 38 | (B) TOP FLOOR |
| 39 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 40 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 41 | Reinforced cement concrete work in arches, archribs, domes vaults, shells folded plate and roofs having slope more than 15* upto floor five level, excluding the cost of centering, shuttering, finishing and reinfrorcement with 1:5:3 (1cement:1.5: Kanaighat coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 42 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level/Above Plinth level. |
| 43 | (b) Thermo-Mechanically Treated bars. |
| 44 | Centering & shutteringincluding strutting , propping etc and removal of form for : |
| 45 | (b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 46 | (d)Arches,domes, vaults exceeding 6m span. |
| 47 | (b) Lintel , beams , plinth beams , girder , bressumers and cantilever with water proof ply 12mm thick |
| 48 | (c ) Suspended floor , roof , landing, balconies ans access platform with water proof ply 12mm thick |
| 49 | (d)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 50 | (f) Stairs, (excluding landings) except spiral-staircases. |
| 51 | Half brick masonry with 1st class common burnt burnt clay FPS in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 cement : 4 Kanaighat coarse sand) |
| 52 | Brick work with Ist class common burnt clay F.P.S.(non modular)bricks in superstructure above plinth level upto floor V level in all shapes and sizes in :(i)cement mortar 1:4 (1 cement : 4Kanhaighatcoarse sand) |
| 53 | Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately 9.1.3. Local best quality Tolhao wood |
| 54 | P/F panelled, glazed or panelled & glazed shutters for doors, windows and clerestory windows i/cISI marked MS butthinges bright finishedof required size with necessary screws excluding panelling which will be paid separately , all complete as per direction of Engineer in charge (b)Local best quality Tolhaowood 35 mm thick shutters |
| 55 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality Tolhao wood |
| 56 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws..(a) Local best quality Tolhao wood.(35mm thick). |
| 57 | Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts andwooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand:6 graded stone aggrt.) |
| 58 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm |
| 59 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (a) 250x10 mm |
| 60 | (b) 100x10 mm |
| 61 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. (a) 125mm |
| 62 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 63 | Providing & fixing M.S. grills of required pattern to wooden frames vertically andhorizontally with M.S. flats at required spacing & frames basedon Architecturaldrawing ..i/cpriming,painting etc.Complete as per direction ofEngineer-in-Charge. |
| 64 | Marble stone flooring in treads of steps and risers using single length upto 2.00 metre with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality. |
| 65 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 Kanhaighat coarse sand) including grouting the joints with white cement and matching pigments etc., complete.(a) Double charge vitrified tile polished finish of size (i) Size of Tile 600x600 mm |
| 66 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 Kanhaighat coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete (i) 8mm thick |
| 67 | Providing and laying Ceramic glazes floor tiles 300 X 300 mm (thickness to be specified by the manufacturer ) of 1st quality conforming to IS : 15622 of approved make in colour such as white, ivory. grey, fume. red, brown laid on 20 mm thick cement mortar 1 : 4 ( 1 cement: 4 Kanhaighat coarse sand ) including pointing the joints with white cement and matching pigment etc complete . |
| 68 | Providing and fixing 1sy quality Ceramic glazed wall tiles conforming to IS : 15622 300 X 300 mm (thickness to be specified by the manufacturer ) of approved make in all colours shades except burgundy, bottle green,black,skirting risers of steps and dados over 12 mm thick bed of cement mortar 1 : 3 ( 1 cement: 3 Kanhaighat coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete . |
| 69 | 12mm cement plaster of mix1:4 (1 cement : 4 Kanaighat coarse sand). |
| 70 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 coarse sand). |
| 71 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer |
| 72 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 73 | Finishing wall with acrylic smooth exterior paint of required shade :- New work (two or more coats applied @ 1.67 ltr / 10 sqm over and i/c base coat of water proofing cement paint applied @2.20 kg / 10 sqm. |
| 74 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade (i) Two or more coats |
| 75 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 76 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 77 | Supplying and Applying Dr. Fixit Primeseal ( after making dilution with water in the ratio 2:1 (2 Primeseal : 1 Water) on new roof at 1 Litre per 9.3 sqm.after cleaning the surface using wire brushor appropriate tools (surface to be washed off with water) and allow drying fo 2-3 hours before applying Dr. Fixit Newcoat over this coat as per direction of the Engineer-in-Charge. |
| 78 | Supplying and Applying Dr. Fixit Newcoat on Primeseal roof surface in three different coats at 1 Litre per1.95 sqm.per coat, laying fibre mesh with adhesive primer (consuming 20 litres for 80 sheets of 3x10m fibre mesh) after 1st coat of Newcoat. 2nd coat of Newcoat should be applied immediately after laying of fibre mesh. 3rd coat of Dr. Fixit Newcoat should be applied after allowing drying of the 2nd coat for 6 to 8 hrs. Each coat should be applied in perpendicular direction to the underlying layer. The entire process should be carried out under strict supervision and direction of the Engineer-in-Charge. |
| 79 | (C) WATER SUPPLY &SANITARY INSTALLATION |
| 80 | Providing and fixing white vitreous china pedestal type watercloset (European type) with seat and lid, 10 litre low level whitevitreous china flushing cistern & C.P. flush bend with fittings &C.I. brackets, 40 mm flush bend, overflow arrangement withspecials of standard make and mosquito proof coupling ofapproved municipal design complete, including painting offittings and brackets, cutting and making good the walls andfloors wherever required : (a) W.C. pan with ISI marked white solid plastic seat and lid. |
| 81 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 82 | P/F P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(a)Flexible pipe(i)32mm dia |
| 83 | Providing and fixing 600x450 mm beveled edge mirror ofsuperior glass (of approved quality) complete with 6 mm thickhard board ground fixed to wooden cleats with C.P. brass screwsand washers complete. |
| 84 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms |
| 85 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 86 | (a) 600 mm long towel rail with total length of 645 mm, width 78mm and effective height of 88 mm, weighing not less than 190gms. |
| 87 | Providing and fixing toilet paper holder(a)C.P. brass |
| 88 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore |
| 89 | P/F 8mm dia C.P./S.S. jet with flexible tube upto 1metre long with S.S triangular plate to European type W.C.of quality and make as approved by Engineer-in-charge. |
| 90 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 (a) 15 mm nominal bore |
| 91 | Providing and fixing gun metal non-return valve of approved quality(screwed end):(a)25 mm nominal bore(i)Horizontal |
| 92 | (ii)Vertical Code |
| 93 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A) Concealed work, including cutting chases and making good the wall etc. |
| 94 | (i) 15 mm nominal outer dia Pipes |
| 95 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works. |
| 96 | Providing and placing on terrace (at all floor levels) polyethylenewater storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 97 | P/F U-PVC pipes (working pressure 4kg/cm2) Single socketed pipe 110mm dia |
| 98 | P/F U-PVC bend 87.5o 110 mm bend |
| 99 | P/F U-PVC single equal Tee (with door)110x110x110mm |
| 100 | P/F U-PVC pipes (working pressure 4kg/cm2) Single socketed pipe 75mm dia |
| 101 | P/F U-PVC bend 87.5o 75mm bend |
| 102 | P/F U-PVC single equal Tee (with door)75x75x75mm |
| 103 | P/F U-PVC plain shoe 110 mm bend |
| 104 | P/F U-PVC plain shoe 75 mm bend |
| 105 | P/F U-PVC pipe clip 75 mm bend |
| 106 | P/F U-PVC pipe clip 110 mm bend |
| 107 | P/F U-PVC pipes (working pressure 4kg/cm2) Rubber(Seal) Ring 110mm dia |
| 108 | P/F U-PVC pipes (working pressure 4kg/cm2) Rubber(Seal) Ring 75mm dia |
| 109 | Providing and fixing S.C.I.gully or nahani grating100mm dia |
| 110 | Providing and fixing100mm S.C.I.trap with 100mm inlet and 75 mm outlet |
| 111 | (D) GROUND SUMP 15000 LITRE CAPACITY |
| 112 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms,lift upto1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. |
| 113 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 114 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:3:6 (1 cement :3 Kanhaighat coarse sand :6 graded stone aggrt. 40mm nominal size). |
| 115 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 116 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 117 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 118 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. |
| 119 | (b) Thermo-Mechanically Treated bars. |
| 120 | Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete. |
| 121 | (g) Walls (any thickness) including attached pilasters, buttresses,plinth and string courses etc. |
| 122 | (d ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 123 | (e)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 124 | Neat cement punning |
| 125 | (E) SEPTIC TANK 30 USERS CAPACITY-2NO. |
| 126 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms,lift upto1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. |
| 127 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 128 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:3:6 (1 cement :3 Kanhaighat coarse sand :6 graded stone aggrt. 40mm nominal size). |
| 129 | (b)1:2:4(1cem:2 Kanhaighat coarse sand:4 graded stone aggrt.20 mm nominal size |
| 130 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 131 | Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 Kanhaighat C/Sand) |
| 132 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth : (i)cement mortar 1:4 (1 cement : 4 Kanhaighatcoarse sand) |
| 133 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. |
| 134 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 135 | (d ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 136 | (e)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 137 | 15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 138 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |