}

Tender For Ict 01 Central Computerized System For Monitoring At Head Quarter Himachal Pradesh Rural Drinking Water Improvement And Livelihood Project, mandi-Himachal Pradesh

Irrigation And Public Health Department has published Tender For Ict 01 Central Computerized System For Monitoring At Head Quarter Himachal Pradesh Rural Drinking Water Improvement And Livelihood Project. Submission Date for this Tender is 13-10-2025. Customised Software Development Tenders in mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51200037
Tender For Ict 01 Central Computerized System For Monitoring At Head Quarter Himachal Pradesh Rural Drinking Water Improvement And Livelihood Project
Tender
Indian
Himachal Pradesh
Mandi
13-10-2025
BootCamp

Tender Details

Ict 01 Central Computerized System For Monitoring At Head Quarter Himachal Pradesh Rural Drinking Water Improvement And Livelihood Project Ict 01 Central Computerized System For Monitoring At Head Quarter , Iot Based Central Computerized System For Monitoring At Command Control Centre To Be Established In The Office Of Pmu, Jsv Mandi (H.P.) India. With Comprehensive Operation & Maintenance For A Period Of Five (5) Years. Supply, Installation, Testing & Commissioning (Inclusive Of Related Design Documentation) Of Iot Based Central Computerized System For Monitoring At Command Control Centre Consisting Of The Following Components On A Minimum But Not Limited To: Software & Implementation Establishment Of Central Command Control Centre In The Office Of Pmu, Jsv Mandi (H.P.) India. Design,Supply, Installation, Testing And Commissioning Of Centralized Command Centerwith Functionality As Per The Following, But Not Limited To: - Open Protocol Iot Based Platform Software With Minimum 30000 Tags, Real Time Data Acquisition From N Remote Scada Locations With Data Analysis, Dashboards, Inclusive Of Any Required Iot Cloud Connection Gateways At Remote Locations. Cloud Software And Any Third-Party Applications To Be Integrated. - Centralized Master Database Management For Field Assets With The Capability To Add, Edit Or Delete Any Asset Information For Seamless Monitoring. Intelligent Water Network Management Application Based On Iot To Be Hosted On-Premises (And Capable Of Cloud Hosting If Required) ,Able To Monitor, Analyze And Predict Sensor-Based Data From The Remote Scadas /Plcs /Hmis/Devices. The Application Shall Provide Quality & Quantitative Analysis For Drinking Water, Source Sustainability Analysis, Energy Management And Individual Device Monitoring Etc. Central Event Management Application: - The Iot Based Centralized Monitoring System Shall Be Supplied With Perpetual Licenses With Minimum 30,000 Tags With Complete Ownership To The End User For Monitoring, Control And Analysis Of 186 Schemes (And Also Future Schemes) Clubbed In 10 Packages Spread Across 10 Districts In Himachal Pradesh Under Himachal Pradesh Rural Drinking Water Improvement Livelihood Project (Adb Funded). And All Other Requirements As Specified Under The Specifications And Shall Be Fully Scalable To Cover Integration With Other Future Schemes Without Any Extra Software Licensing Or Software, Propriety Software Or Hardware/Gateway. The Software Application Shall Be Developed And Implemented Ensuring Seamless Integration Of Future Schemes. Note: 1)The Perpetual License Shall Cover The Requirements Of Tags Required The Entire Duration Of The Contract, Inclusive Of Tags Required During The O&M Period And In Future For Integration Of Future Schemes, Without The Requirement Of Any Propriety Software Or Hardware/Gateway. 2)The Quote Should Be Inclusive Of All Required Software Developments And Software Installations Required For Successful Running Of Developed Software At Local Scada Centre/ Scada Implementing Computer System For All The Schemes Under The Project, Required For The Successful Implementation Of The Package , Real Time Asset Management System For The Network Integrated.The Data For The Same Shall Be Obtained From The Local Db Contract Packages.The Bidder Shall Co-Ordinate For The Data With The Concerned Contract Packages With Assistance From The Jsv Mandi. , Mobile Application For Android/Ios For Accessing Data As Per Access Rights. The End User Shall Be Provided An Mobile Application (Android,Ios)Through Which The Utility Staff Shall Be Able To Monitor The Related Network And Access The Related Data In Real Time And Also View The Historical Data As Per Requirement.Integration Guideline Document For Future Plants Integration: - Shall Detail And Illustrate The System Functionality And The Various Protocols Adopted At The Command Center For Data Integration From The Remote Sites To Allow Integration From Any Remote Stations, Without The Requirement Of Any Propriety Software Or Hardware. The Document Shall Also Include Details On The Various Parameters That Shall Be Included For Monitoring And Integration From The Remote Locations. , Hardware Equipment’S To Be Implemented Rack Based Server System As Per Specifications +Rack Cabinet Inclusive Of Rack Monitoring System Complete With 22Lcd Monitor & Computer Note: 1. All Miscellaneous/Ancillary Items, Installation Materials, Accessories Or Peripheral/S Not Specified In The Bid Document But Required For The Successful Implementation & Complete Functioning Of The Central Command Centre Be Assessed & Supplied By The Bidder And The Cost Of The Same (Including Installations & Configuration) Be Included Under Boq Item No. 4. , 14 Nos. Vms,Vcpu Committed Ratio Shall Be 1 Virtualization Clustering Solution To Deploy Vms (Virtual Machines) With Ha And Load Balancing And Redundancy. My Sql Database Server With Softkey 1 Redundant Server & 1 Standalone Server Windows And Windows Server Licensing Window Os License Shall Be Windows Server 2022 Standard Enterprise Grade Component To Be Considered With Hot Swappable Ssd Drives With Raid-5 Configuration,Online Redundant Power Supply.Nas Storage For Database Backup & Archiving. , Providing, Installation, Testing And Commissioning Of Precision Air Conditioning (Pac) System (Hot & Cold,12 Tr Capacity For Server Room (Approx.Area ~155.7 Sqm) Complete With All Required Accessories, Suitable For 24X7 Operation To Maintain 22°C ±2°C And Humidity As Per Server Requirement And Access Control Systems, Complete In All Respects. , Operating Work Stations With 32 Dual Led Monitor +All Required Iot Software +Licensed Latest Windows Os,Anti Virus Software,Ms Office Latest Version. , Desktop Work Stations For Centralized Command Center Operating Staff +Latest Windows Os+Ms Office+ Adobe Pdf Reader ,Etc… As Required Under Specifications , Led Videowall Display System -55(Inches) With 3X4 Configuration , With Required Video Controller System (Latest Configuration With Auto Calibration) ,Required Mounting Accessories, All Required Hardware & Software For Integration And Display Of Mimics And Cctv Feeds, Etc,, As Per Specifications , Multifunction Color Laser Printers (Scan, Copy, & Printa3 & A4 Size) , Ancillaries To Be Provided At Centralized Command Center Hi Speed Broadband Leased Line To Control Center/Iot Gateways And All Central Location For Receivingdata From Various Remote Stations With All Required Hardware, Routers, Etc. With Ethernet Tcp/Ip Connectivity, Providing And Installation Of Network Facility Complete In All Respects For Effective And Smooth Functioning Of The Command Centre With Concealed Network Cabling Including Installation Of Ethernet Switches, Routers With Wifi Etc. , Hardware Based Firewall+ Software Firewalls With Complete Cyber Security Solution ,Web Security Audit ,For The Command Center, Fully Scalable Without Any Limitations As Per Specifications And Cyber Audits , Antivirus Software-Enterprise Version(With Minimum 10 Client Licenses And As Required ) To Cover All Systems. , Bio-Metric Access Control System (Complete With Finger Print ,Pin & Em Proximity Card Reader/Software, Required Hardware) For The Control Center , Industrial Managed Ethernet (24 Port) Switches (Redundant Configuration ) , Epabx System For Control Center - Each Desk In The Control Center Shall Be Networked And Provided , Conference Room - Over Head Projector System With Screen, Conference Table With Ergonomic Designed Chairs, Other Required Ancillaries , Required Minor Civil & Interior Design Works At The Centralized Command Control Center Interior Design Works To Augment The Command Center As Per Control Center Standards To The Approval Of The Engineer, Presentation Room Facilities, Glass Partitions, Fire Rated Glass Partitions For Server Room And Control Room Area, False Ceiling & False Flooring For Command Center ,Logo Stickers Etc.. As Per Specification Requirements And To The Approval Of The Engineer. , Industrial Type Control System Consoles For Main Command Control Room Area Of Command Center, Ergonomic Chairs, Work Desks, Tables, Furniture To Augment Control Room Design, Presentation Room Facilities, Cabinets Etc As Per Requirements & Specifications , Fire Alarm System:- Fire Detection,Fire Alarm & Gas Suppression System ,Aspiration System,Addressable Fire Alarm System,Fire Extinguishers,Etc For The Entire Command Center Along With Central Control Panel And Integration Complete In All Respects As Per The Relevant Is Code Specifications. , Cctv System With Night Mode View Enabled Cameras For The Control Center-Inclusive Of Indoor Cameras(5 Nos) + Outdoor (2 Nos) Inclusive Of Cctv Control System, Data Archiving System, All Related Accessories, Interface To Led Videowall System Etc. As Required Under Specifications , Ups System - 2 X 20 Kva, Parallel Redundant (Ups A +Ups B), Three Phase, 415V, 50Hz, Standalone, Online, Microprocessor Based Ups System With Smf Batteries For 120 Minutes Backup On Full Load With Accessories. , Providing Electrical Installation (As Per Relevant Is Code For Industrial Buildings) Complete In All Respects As Per Requirements For Set-Up Of Command Control Centre. (Power Supply Up To Command Centre Building Will Be Provided By Jsv) Note 1: The Iot Based Centralized Monitoring System Supplied Shall Be Flexible To Deploy On Government Cloud Or On State Data Center As Per The Direction Of Engineer In Charge At A Later Date ,(If Required). Note 2:-The Total Resource Requirement Given Above Shall Be Considered As Minimum Configuration/Requirements To Be Provided And Prospective Bidders Shall Do Their Own Due Diligence Beforehand. , Comprehensive Operation & Maintenance Of All Equipment(Hardware, Software, All Control Center Equipment & Associated Systems) Installed Under This Contract With Preventive And Predictive Maintenance, Replacement & Repair For A Period Of Five (5) Years The Bidder Shall Consider The Below Mentioned Requirements(A-F) For Each Year Of Comprehensive Operation & Maintainance. Comprehensive O&M For 1St Year A)Man Power For Running The Command Center As Per Specifications, Security Staff, + All Required Manpower For Carrying Out Comprehensive & Predictive O&M+ Manpower For Carrying Out Repair Works/Replacement Works(Inclusive Of All Incidentals, Travel & Boarding Cost ) +Manpower As Required For Integration Of New And All Other Facilities That Shall Be Made Available For Integration With The Command Center Along With Data Analytics, Dashboards, Reports As Required ,+ All Other Manpower & Related Cost Required Under The Specifications For Carrying Out Comprehensive O&M B)Data Communication Cost Between Various Remote Sites With Centralized Command Center Inclusive Of Leased Line And Related Costs ,High Speed Broadband Internet Charges, Telephone/Smartphone(Andriod /Ios) Recurring Monthly & Yearly Costs, All Other Communication Costs Plus Incidental Cost As Required Under The Specifications For Carrying Out Comprehensive O&M C)All Software Licensing, Regular Software Patch Upgrade For All Software As And When Made Available By Oem With Time Stamping, Applicable For All Machines Installed In The Control Center, Servers, Server Components, Display Wall Video Controllers Software, Cyber Security Audit,Etc. Plus All Other Softwares Licensing And Related Incidental Cost As Required Under The Specifications For Carrying Out Comprehensive O&M D)Operation & Maintenance Of The Iot Software Modules Inclusive Real Time Asset Management System Inclusive Of All Addition, Deletion Of Equipment/Documentation Available During The O&M Period .Cyber Security For The Centralized Command Center & Installed Components To Prevent Any Cyber/Hacking Attacks , Intrusion Protection & Antivirus Protection For All Components, Software Programming & Integration Of Newly Added Plants/Locations With All Field Data To Be Integrated To The Command Enter As Applicable With Analytics, Dashboards, Reports, Synoptical Views, Interoperability Test Procedures, Communication Checks With All Remote Sites At Regular Intervals, Communication Checks With All Networked Components In The Control Center, Integration With All Servers And Machines Installed At Control Center. E)Operation & Maintenance Of All Electrical Equipment Installed At The Control Center, Inclusive Of Ups System With Batteries, Security Of All Installed Systems, Equipment, All Electrical Equipment, Etc +All Other Items And Incidental Cost As Required Under The Specifications For Carrying Out Comprehensive O&M. F)All Other Miscellaneous Items And Incidental Cost As Required Under The Specifications For Carrying Out Comprehensive O&M For Period Of 5 Years. , Comprehensive O&M For 2Nd Year , Comprehensive O&M For 3Rd Year , Comprehensive O&M For 4Th Year , Comprehensive O&M For 5Th Year Note: In Addition To The Requirements Specified Under (A-F) Above For Activities To Be Performed For Each Year, The Bidder Shall Consider During 5Th Year Of Comprehensive Operation & Maintenance Of All Equipment (Hardware, Software, All Control Center Equipment & Associated Systems Inclusive Of Any Iot Gateways Installed) Installed Under This Contract With Preventive And Predictive Maintenance, Replacement Of It Hardware Servers, Workstations, Upgradation To Latest Iot Based Software Version With License, Replacement Of Ups Batteries Etc. As Required Under The Specifications.Note: The Iot Based Software Shall Be Upgraded With Minimum 50% Of The Total Tags Consumed Out Of The Original 30,000 Tags. I.E 30,000(Original)+ 50% Qty Of Original Tags Consumed. The It Hardware, Required Gateways, Cyber Security Systems Shall Be Sized To Cater To This Requirement.

Key Value

Document Fees
INR 5000 /-
EMD
INR 500000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail