}

Tender For Provision Of Deficient 100 Dus At Af Station Sarsawa Under Ge(Af) Sarsawa., sarsawa-Uttar Pradesh

Military Engineer Services has published Tender For Provision Of Deficient 100 Dus At Af Station Sarsawa Under Ge(Af) Sarsawa.. Submission Date for this Tender is 21-10-2025. Civil Work Tenders in sarsawa Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51195708
Tender For Provision Of Deficient 100 Dus At Af Station Sarsawa Under Ge(Af) Sarsawa.
Tender
Indian
Uttar Pradesh
Sarsawa
21-10-2025
BootCamp

Tender Details

Tender For Provision Of Deficient 100 Dus At Af Station Sarsawa Under Ge(Af) Sarsawa.; 1 SCHEDULE `A PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates0.00 under column 5 signifies this fact only. 2 Design and construction of Sqn Leader & above accn in five storey (G+4 storey) having 2 DU per floor including accn for servent quarters and lift well complete all as specified and as shown on drawings. 3 Design and construction of Flt Lt accn in two stoery (G+1 storey) having 2 DU per floor including accn for servent quarters complete all as specified and as shown on drawings. 4 Design and construction of Warrant rank accn in seven storey (G+6 storey) having 2 DU per floor including lift well complete all as specified and as shown on drawings. 5 Design and construction of Sgt & below accn in seven storey (G+6 storey) having 4 DU per floor including lift wells complete all as specified and as shown on drawings. 6 Design and construction of Type III Civilian Md accn three storey (G+2 storey) having 2 DU per floor in permanent accn complete all as specified and shown on drawings. 7 Design and construction of Type II Civilian Md accn three storey (G+2 storey) having 2 DU per floor in permanent accn complete all as specified and shown on drawings. 8 Design and construction ofGarrages including ramp for SQN LDR and above Accn complete all as specified and shown on drawings. 9 Design and construction of Garrages including ramp for FLT LT Accn complete all as specified and shown on drawings. 10 Design and construction of car and scooter Garrages including ramp for Warrant rank Accn complete all as specified and shown on drawings. 11 Design and construction of car and scooter Garrages including ramp for SGTand below Accn complete all as specified and shown on drawings. 12 Design and construction of Garrages including ramp for Type III Civillian Accn complete all as specified and shown on drawings. 13 Design and construction of Garrages including ramp for Type II Civillian Accn complete all as specified and shown on drawings. 14 Design and construction of Garbage bin with permanent specifications all as specified and as shown on drawings. 15 Design and construction of Service Toilet complete all as specified and shown on drawings. 16 Design and construction of UG Sump of capacity 20000 Gallon (free board of 0.50 M) with permanent specifications includingnecessary earthwork, foundation PCC, RCC M-30 (Design Mix), steel reinforcement, PCC plinth protection and all necessary connected itemsall as specified and shown on drawings. 17 Design and construction of UG Sump of capacity 25000 Litres (free board of 0.50 M) with permanent specifications includingnecessary earthwork, foundation PCC, RCC M-30 (Design Mix), steel reinforcement, PCC plinth protection and all necessary connected itemsall as specified and shown on drawings. 18 NOTE: Schedule ‘A’ Part IIto XII under Ser No 2.01 to 2.11 are Prepriced by MES. 19 Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part-II 20 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’Part-III 21 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’Part-IV 22 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL as listed in Schedule ‘A’Part-V 23 Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK ” as listed in Schedule ‘A’Part-VI 24 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY as listed in Schedule ‘A’Part-VII 25 Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’Part-VIII 26 Lump sum price worked out by the Contractor for “ROAD, PATH AND HARDSTANDING ” as listed in Schedule ‘A’Part-IX 27 Lump sum price worked out by the Contractor for “FIRE ALARM & FIRE FIGHTING WORK ” as listed in Schedule ‘A’Part-X 28 Lump sum price worked out by the Contractor for “LIFT WORK ” as listed in Schedule ‘A’Part-XI 29 Lump sum price worked out by the Contractor for “LIGHTNENING PROTECTION ” as listed in Schedule ‘A’Part-XII 30 S&F 6 mm thik glass corner shelf fancy type with railing and fitting complete of size 25cm x 25 cm of best quality (as per sample approved by Engr -in-charge) complete all as specified. 31 S&F brass chromium plated towel rack, 60 cm long between flanges and 25 cm in width with 04 no hooks complete all as specified and directed. 32 SCHEDULE `A PART - XIII MISC ITEMS (B/R & E/M)is not prepriced by MES and prepriced rates indicated as 0.00 under column 5 signifies this fact only. 33 “INTERNAL ELECTRIC SUPPLY 34 S&F sheet metal enclosures Vertical type doubledoor (VTPN) MCCB incomer, with Acrilic Door, cement spill protector For MCCB Triple pole and neutral, 8 ways, IP-43 protection, with 100 Amps rated bus bar breaking capacity 25KA, 415 Volts complete all as specified and directed by Engineer-in-Charge. 35 S&F telephone jack complete all as specified and directed 36 S&F T V Jack complete all as specified and directed. 37 Design and construction of Rain Water Harvesting System (RWH)includingnecessary earthwork, foundation PCC, RCC Slab, steel reinforcement,brick work, UPVC pipes, gravels of necessary sizes and all necessary connected itemscomplete all as specified. 38 “EXTERNAL WATER SUPPLY 39 S&F openwell submersible pumpset having discharge and head not less than 80 LPM X 30 mtr head and outlet dia of 40mm bore with chrome steel impeller and strainer, including motor of suitable capacity to run on 230 volts, 1 phase, 50 Hz cycles A/C power supply including lifting chain, cable, starters, panel, etc. complete with other accessories as required. 40 S&F openwell submersible pumpset having discharge and head not less than 260 LPM X 33 mtr head and outlet dia of 80mm bore with chrome steel impeller and strainer, including motor of suitable capacity to run on 415 volts, 3 phase, 50 Hz cycles A/C power supply including lifting chain, cable, starters, panel, etc. complete with other accessories as required. 41 M&L for construction of brick masonry valve pit of size 90×90×90 cm (internal dimension) with MS top cover of 3mm thick sheet, fixed on frame made out of angle iron 40×40×6mm thick with locking arrangement including two coats of synthetic enamel paint over a coat of zinc chrome primer to MS sheet internally and externally & iron surface, brick work in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally & externally), 150 thick plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate for base, 100mm thick PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate for coping, two coats of white wash internally after preparation the surface complete all as specified and as shown on drawings. 42 M&L for construction of brick masonry valve pit of size 60×60×60 cm (internal dimension) with MS top cover of 3mm thick sheet, fixed on frame made out of angle iron 40×40×6mm thick with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primer to MS sheet internally and externally & iron surface, brick work in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally & externally), 150 thick plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate for base, 100mm thick PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate for coping, two coats of white wash internally after preparation the surface complete all as specified and as shown on drawings. 43 “EXTERNAL ELECTRIC SUPPLY 44 Shifting of transformer 11/0.433 KV, 160 KVA rating from E/M store yard to proposed location for Sqn Leader and above area, using hydra & tractor trolley complete as specified and directed. 45 M&L for Construction of platform for transformer of size 2.5 x 2.5 x 1.5 mtr with following specifications:-a) Earth work in soft/loose soil b) 15 cm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as lean concrete in foundation c) Brick work with sub class ‘B’ brick built in cement mortar 1:4. Space between walls filled with aggregates duly rammed of size 45–60 mm d) 75 mm thick PCC 1:2:4 type B1 using 20 mm graded aggregate over brick platform e) Chain link on fencing post of size 40 x 40 x 6 mm of height 1.80 mtr at 2 mtr c/c around brick platform including excavation and earth work in soft/loose soil and angle iron PCC 1:2:4 of size 60 x 60 x 60 cm f) Chain link fencing of height 1.80 mtr made out of GI wire not less than 3 mm and pitch not more than 75 mm g) Angle iron gate using 40 x 40 x 6 mm angle iron 2 x 1.5 m with vertical flat 25 x 6 mm @ 10 cm (±10%) including hinges & locking arrangement h) 15 mm thick plaster in CM 1:6 on brick masonry platform j) All exposed surfaces of steel work shall be given two coats of synthetic enamel paint over a coat of red oxide primer k) Stair case of brick masonry for easy access to the plate. 46 Supply and fix Lightning arrester, expulsion type, transmission class, having discharge capacity 10KA, suitable for HT 11 KV complete all as specified and directed. 47 Supply, installation, testing & commissioning of LT panel board outdoor type, IP 66 protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet, double door, front and back opening with proper locking arrangement, lifting lugs, rubber gasket on front and back to make it dust and vermin proof, powder coated including 4-pole, 1000 Amp rated aluminium busbar sleeved with heat shrink sleeve with colour coding (RYB) and with provision of suitable size of FRLS copper cable. Panel shall be provided with 4 legs of angle iron of size 50 x 50 x 6 mm each 750mm long (300mm grouted in PCC and 450mm above GL)(Main panel for WO, SGT, Type 3 & 2 Qtrs)(a) ACB, 4 pole 415 volt, Manual draw type microprocessor based 630 Amps capacity 50KA – 01 No(b) Amp meter (0-600Amp) Square dial 100x100mm complete with selector switch – 01 No.(c) Volt meter (0-500V) Square dial 100x100mm complete with selector switch – 01 No.(d) LED indicating lamps three Nos (RYB) – 01 Set(e) CT coil of ratio 600/5 Amp-01 Set (of 03)Outgoing:(a) MCCB 4 pole 415 volt, 250 Amps 25 KA rating - 01 No. (for AMF Panel)(b) MCCB 4 pole 415 volt, 200 Amps 25 KA rating - 02 No. (for SGTs bldg 02 Nos)(c) MCCB 4 pole 415 volt, 100 Amps 16 KA rating - 02 No. (for WOs bldg Type II & III Qtrs)(d) MCB SPN 240 volt, 6 Amps 10 KA rating - 02 No. (for garages)(e) Timer Switch analog type with contractor relay and bypass arrangement, 230 volts single phase of 20 Amps rating - 01 Nos 48 Supply, installation, testing & commissioning of LT panel board, outdoor type, IP 66 protection, suitable for operation on 415V AC, 3 phase, 4 wire, 50Hz supply system, made of 3.15mm CRCA sheet, double door (front & back), locking arrangement, lifting lugs, rubber gasket, powder coated, 4-pole 400A aluminium busbar with RYB coding, FRLS copper wiring, with legs of angle iron 50×50×6mm (750mm long, 300mm grouted PCC, 450mm above GL). Essential service panel near DG. IIncoming:(a) MCCB 4-pole 415V, 250A, 25KA rating - 01 No.(b) Amp meter (0-600Amp) Square dial 100x100mm complete with selector switch – 01 No.(c) Volt meter (0-500V) Square dial 100x100mm complete with selector switch – 01 No.(d) LED indicating lamps three Nos (RYB) – 01 Set(e) CT coil of ratio 600/5 Amp-01 Set (of 03)Outgoing:(a) MCCB 4 pole 415 volt, 63 Amps 10 KA rating – 03 No. (for Ess Services of WO, SGT bldg)(b) MCB TPN 415 volt, 32 Amps 10 KA rating – 01 No. (for Ess Services of type 3 & 2 bldg) (c) MCB TPN 415 volt, 10 Amps 10 KA rating – 01 No. (for pump) 49 Supply, installation, testing & commissioning of LT panel board outdoor type, IP 66 protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet, double door, front and back opening with proper locking arrangement, lifting lugs, rubber gasket on front and back to make it dust and vermin proof, powder coated including 4-pole, 100 Amp rated aluminium busbar sleeved with heat shrink sleeve with colour coding (RYB) and with provision of suitable size of FRLS copper cable. Panel shall be provided with 4 legs of angle iron of size 50 x 50 x 6 mm each 750mm long (300mm grouted in PCC and 450mm above GL)(01 each for Sqn Ldr & WO, Sgt (02) Bldg for ess services)Incoming:(a) MCCB, 4-pole 415 volts 63 Amps 10KA rating – 01 No.(b) Amp meter (0–100Amp) Square dial 100x100mm complete with selector switch – 01 No.(c) Volt meter (0–500Amp) Square dial 100x100mm complete with selector switch – 01 No.(d) LED indicating lamps three Nos (RYB) – 01 Set(e) CT coil of ratio 100/5 Amp – 01 Set (of 03)Outgoing:(a) MCB TPN 415 volt, 32 Amps 10 KA rating – 03 No. (for Lifts and Terrace pump)(b) MCB SPN 240 volt, 6 Amps 10 KA rating – 03 No. (Aviation light and Fire alarm panel) 50 Supply, installation, testing & commissioning of LT panel board, outdoor type, IP 66 protection, suitable for operation on 415V AC, 3 phase, 4 wire, 50Hz supply system, made of 3.15mm CRCA sheet, double door (front & back), proper locking arrangement, lifting lugs, rubber gasket (dust & vermin proof), powder coated, 4-pole 250A aluminium busbar with RYB coding, FRLS copper wiring, with legs of angle iron 50×50×6mm (750mm long, 300mm grouted PCC, 450mm above GL). Main panel near Sqn Ldr Bldg. Incoming: (a)MCCB 4-pole 415V, 250A, 25KA (1 No.), (b)Amp meter 0–200A with selector switch (1 No.), (c)Voltmeter 0–500V with selector switch (1 No.), (d)LED RYB lamps (1 set),(e)CT coil 200/5 Amp (1 set of 3). (e) CT coil of ratio 200/5 Amp- 01 Set (of 03)Outgoing: (a)MCCB 4-pole 415V, 100A, 16KA (2 Nos. for bldg-02), (b)MCCB 4-pole 415V, 63A, 10KA (1 No. for AMF panel), (c)MCB SPN 240V, 6A, 10KA (2 Nos. for Garage 1 & 2),(d)Timer Switch analog type with contractor relay and bypass arrangement, 230 volts single phase of 20 Amps rating- 01 Nos. 51 Supply, installation, testing & commissioning of LT panel board, outdoor type, IP 66 protection, suitable for operation on 415V AC, 3 phase, 4 wire, 50Hz supply system, made of 3.15mm CRCA sheet, double door (front & back), proper locking arrangement, lifting lugs, rubber gasket (dust & vermin proof), powder coated, 4-pole 200A aluminium busbar with RYB coding, FRLS copper wiring, with legs of angle iron 50×50×6mm (750mm long, 300mm grouted PCC, 450mm above GL). Main panel near Flt Lt Bldg. Incoming: (a)MCCB 4-pole 415V, 100A, 16KA (1 No.), (b)Amp meter 0–100A with selector switch (1 No.), (c)Voltmeter 0–500V with selector switch (1 No.), (d)LED RYB lamps (1 set), (e)CT coil 100/5 Amp (1 set of 3).outgoing:(a)MCCB 4 pole 415 volt, 100 Amps 16 KA rating- 02 No.(for bldg- 02) (b)MCCB 4 pole 415 volt, 63 Amps 10 KA rating- 01 No.(for AMF panel) (c)MCCB SPN 240 volt, 6 Amps 10 KA rating- 02 No. (garaage 1 & 2)Outgoing: (a)MCCB 4 pole 415 volt, 63 Amps 10 KA rating- 02 No.(for Bldgs) (b)MCCB SPN 240 volt, 6 Amps 10 KA rating- 02 No. (For Garaage) 52 Supply, installation, testing & commissioning of LT panel board outdoor type, IP 66 protection, suitable for operation on 415 V AC, 3 phase, 4 wire, 50 Hz electric supply system, made of 3.15 mm thick CRCA sheet, double door (front & back), proper locking arrangement, lifting lugs, rubber gasket (dust & vermin proof), powder coated, 4-pole, 150 Amp rated aluminium busbar with heat shrink sleeve (RYB coding), wiring with FRLS copper cable. Panel with 4 legs of angle iron 50×50×6 mm, 750 mm long (300 mm grouted in PCC, 450 mm above GL). (Near WO Bldg). Incoming: (a)MCCB 4-pole 415 V, 100 Amps, 16 KA – 1 No., (b)Amp meter (0–100A) with selector switch – 1 No., (c)Voltmeter (0–500V) with selector switch – 1 No., (d)LED RYB lamps – 1 set, (e)CT coil 100/5 Amp – 1 set (of 3). Outgoing: (a)MCCB 4-pole 415 V, 63 Amps, 10 KA – 2 Nos. (for Bldgs), (b)MCB SPN 240 V, 6 Amps, 10 KA – 2 Nos. (for Garage). 53 Supply, installation, testing & commissioning of LT panel board outdoor type, IP 66 protection, suitable for operation on 415 V AC, 3 phase, 4 wire, 50 Hz electric supply system, made of 3.15 mm thick CRCA sheet, double door (front & back), proper locking arrangement, lifting lugs, rubber gasket (dust & vermin proof), powder coated, 4-pole, 300 Amp rated aluminium busbar with heat shrink sleeve (RYB coding), wiring with FRLS copper cable. Panel with 4 legs of angle iron 50×50×6 mm, 750 mm long (300 mm grouted in PCC, 450 mm above GL). (Near Sgt Bldg). Incoming: (a)MCCB 4-pole 415 V, 200 Amps, 25 KA – 1 No., (b)Amp meter (0–200A) with selector switch – 1 No., (c)Voltmeter (0–500V) with selector switch – 1 No., (d)LED RYB lamps – 1 set, (e) CT coil 200/5 Amp – 01 Set (of 03) Outgoing: (a)MCCB 4-pole 415 V, 63 Amps, 10 KA – 4 Nos. (for Bldgs).(b)MCB SPN 240 V, 6 Amps, 10 KA – 2 Nos. (for Garage). 54 Supply, installation, testing & commissioning of LT panel board outdoor type, IP 66 protection, suitable for operation on 415 V AC, 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet, double door (front & back), proper locking arrangement, lifting lugs, rubber gasket (dust & vermin proof), powder coated, 4-pole, 150 Amp rated aluminium busbar with heat shrink sleeve (RYB coding), wiring with FRLS copper cable. Panel with 4 legs of angle iron 50×50×6 mm, 750 mm long (300 mm grouted in PCC, 450 mm above GL). (Near Type II & III Qtrs). Incoming: (a)MCCB 4-pole 415 V, 100 Amps, 16 KA – 1 No.,(b)Amp meter (0–100A) with selector switch – 1 No., (c)Voltmeter (0–500V) with selector switch – 1 No., (d)LED RYB lamps – 1 set, (e)CT coil 100/5 Amp – 1 set (of 3). Outgoing: (a)MCCB 4-pole 415 V, 63 Amps, 10 KA – 2 Nos. (for Bldgs), (b)MCB SPN 240 V, 6 Amps, 10 KA – 2 Nos. (for Garage). 55 Supply, installation, testing & commissioning of LT panel board outdoor type, IP 66 protection, suitable for operation on 415 V AC, 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet, double door (front & back), proper locking arrangement, lifting lugs, rubber gasket (dust & vermin proof), powder coated, 4-pole, 50 Amp rated aluminium busbar with heat shrink sleeve (RYB coding), wiring with FRLS copper cable. Panel with 4 legs of angle iron 50×50×6 mm, 750 mm long (300 mm grouted in PCC, 450 mm above GL). (Essential services Type II & III Qtrs). Incoming: (a)MCB TPN 415 V, 32 Amps, 10 KA – 1 No., (b)Amp meter (0–30A) with selector switch – 1 No., (c)Voltmeter (0–500V) with selector switch – 1 No., (d)LED RYB lamps – 1 set, (e)CT coil 30/5 Amp – 1 set (of 3). Outgoing: (a)MCB TPN 415 V, 16 Amps, 10 KA – 2 Nos. (for Terrace Pump). 56 Note for item no 3.10 to 3.18:(i) All MCCB shall be with adjustable Thermal magnetic setting (TMD).(ii) The board shall be epoxy polyester powder coated with structure siemens gray shade RAL-7035.(iii) Sheet metal works shall be processed with 7 tank process i.e. degreasing, water rinsing, activation, phosphating, water rinsing, passivation and water drying.(iv) Busbar shall be of electrolytic grade aluminium and shall be insulated with Red, Yellow, Blue and Black colour heat shrinkable PVC Sleeves.(v) Earth bus of aluminium shall run throughout the length of the panel at the bottom.(vi) Each feeder shall be provided with individual inscription plate made out of black anodized Al/polycarbonate sheet with engraved/painted letters.(vii) Power switches/MCCB’s will be provided with door operating mechanism & door interlock and padlocking feature.(viii) Danger notice board with conventional skull & cross bones symbol shall be provided on front & rear side.(ix) All incoming & outgoing feeder shall be provided with gland plates for cable exit of cable.(x) All MCCB’s to be provided with external rotary operating handle.(xi) All type test certificate and design verification with switch gears (ACB & MCCB) as per.(xii) All panels shall be procured from CPRI manufacturere.(xiii) The panel shall be inspected by rep of CWE before dispatch to the site. 57 Supply & fixing Hot dipped galvanized octagonal pole of 8 mtr height having top dia 70mm, bottom dia 130mm, sheet thickness 3mm, base plate of size 220mm×200mm×12mm, foundation bolt 4×M20×750 (Noxidaxlength) with PCD 225mm, complete with in-built junction box with cable termination arrangement, 1mtr long single arm bracket of hot dipped GI including necessary foundation as per manufacturer’s design & specifications. (Note: Excavation & RCC foundation shall be measured and paid separately). 58 Supply & Fix non-metallic junction box made out of thermoplastic of size 250×250×160 mm for street light poles with connector for connection incoming and outgoing cables including provision of 01 No MCB SP 2.5 Amp to control the pole light circuit including 04 × aluminium bus bars strips 150×30×3mm of size mounting on the insulator and fixing clamp made of FI 25×3 mm with back strip with suitable nut, bolts, washers including double compression cable glands for incoming and outgoing cables complete as specified and directed. 59 Supply & Fix PVC insulated copper wire 1.5 sqmm 3 core for street light fitting drawn through pole from junction box to fitting complete as specified and directed. 60 Supply & Fix LED Aviation light 10 W, IP 65 comprising of aluminium housing with polycarbonate enclosure complete. 61 S&F cable route marker of MS plate of size 100mmx100mmx5mm thick fixed on angle iron of size 25x4mm, 600mm long duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer and writing of cable details as directed by Engr-in-charge. Note : Necessary PCC & earth work deemed to be included in quoted rates. 62 S&F MCCB 125 Amps 4 pole 16 KA duly enclosed in outdoor type sheet metal enclosure made out of 3.15mm thick CRCA sheet provided with 02 Nos mounting legs of angle iron of size 40x40x5mm, 450mm long each duly grounted in PCC (1:4:8) type D2 complete with cable gland for entry and exit point of cable complete. (Loc: Flt ltn qtr tapping point) 63 S&F MCCB 250 Amps 4 pole 25 KA duly enclosed in outdoor type sheet metal encloser made out of 3.15mm thick CRCA sheet provided with 02 Nos mounting legs of angle iron of size 40 x40x 5mm, 450mm long each duly grounted in PCC (1:4:8) type D2 complete with cable gland for entry and exit point of cable complete (Loc: Sqn Ldr near tapping point) 64 Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 16 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed. (for Aviation obstruction light) 65 Supply and fixing HDPE DWC pipe having OD/ID of size 40/32mm as per IS 16205 (Part 24) for electric cable protection across road/hardstanding/along poles complete with coupler all as specified and as directed. 66 Supply and fixing HDPE DWC pipe having OD/ID of size 63/50mm as per IS 16205 (Part 24) for electric cable protection across road/hardstanding/along poles complete with coupler all as specified and as directed. 67 Supply and fixing HDPE DWC pipe having OD/ID of size 110/95mm as per IS 16205 (Part 24) for electric cable protection across road/hardstanding/along poles complete with coupler all as specified and as directed. 68 Boring of holes under road, pavement, hard standing, size upto 150mm for passing of cable/pipe using necessary T&P complete all as specified and directed. 69 “FIRE ALARM & FIRE FIGHTING WORK ” 70 Supply and fix Fire alarm control panel zone card Conventional type complete all as specified and directed 71 Supply and fix conventional manual call point resettable type complete all as specified and directed 72 Supply and fix conventional sounder/ Hooter complete all as specified and directed 73 Supply and fix Repeater control panel with suitable for 40 manual call point complete all as specified and directed 74 Supply, installation, testing and commissioning of Electric Terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system. The panel should be suitable for automatic operation for the fire pump having discharge 900 LPM and Head 36 mtr. The panel shall be completely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Continuous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable entries complete all as specified and directed Note: (a) Complete system shall be installed by a firm dealing with such system or any authorized rep of firm.(b) Any minor items required for successful operation of the system deemed to be included in the overall rates quoted. 75 Supply, installation, testing and commissioning of Electric Terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system. The panel should be suitable for automatic operation for the fire pump having discharge 450 LPM and Head 36 mtr. The panel shall be completely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Continuous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable entries complete all as specified and directed Note: (a) Complete system shall be installed by a firm dealing with such system or any authorized rep of firm. (b) Any minor items required for successful operation of the system deemed to be included in the overall rates quoted. 76 Supply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle, MS sheet 2 mm thickness complete all as specified and directed. 77 Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to enclose fire brigade inlet connections fabricated from 16 gauge sheet with full fr.ont glass door and locking arrangement painted and mounted on masonry platform complete all as specified and directed 78 S&F Exit Light self contained 6W luminaire with flush mounting frame, sign label, fluorescent tube Li battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required complete all as specified and directed. 79 “DG SET ” 80 Supply, installation, commissioning and testing silent diesel engine driven Gen set 125 KVA capacity 415 volts, 3 phase, 4 wire acoustic weather proof enclosure as per latest CPCB-IV norms and noise level shall not exceeding 75 db at a distance of 1 metre, Engine as per IS-10001/1002 and alternator as per IS-13364 installed on PCC platform as per manufacturers recommendation complet comprising the following components: (a) Diesel Engine:- Diesel engine develping suitable BHP, 1500 RPM water cooled engine inclusive of the following standard accessories(i) Spider coupling guard (ii) Fly wheel (iii) Fly wheel housing complete with starter gear ring and coupling (iv) Fuel pipe (v) Air cleaner (vi) Fuel & Lub oil filter (vii) by pass filter (viii) Lub oil pump (ix) Electric Starter 12 Volts DC (x) Battery charging generatory (DC alternator) (xi) Industrial silencer (xii) Lub oil cooler (xili) flexible pipe for sinencer (xiv) DC voltmeter (xv) lub oil pressure gauge, lub oil/water temperature guage (xvi) Speedo meter and engine running hours meter (xvi) Display for fault (xvii) Governor (xviii) Battery as per manufacturer recommendation- 01 No (b) ALTERNATOR: Alternator suitable for continous operation generation 125 KVA at 1500 RPM 415 V at NTP, 0.8 power factor 3 phase, 50Hz, self excited and regulated with ball/roller bearing confirming to IS -4722 (c) AMF PANEL (in built in canopy): AMF panel, factory made, indoor, cubical type, front open able fabricated out of CRCA sheet 2 mm thick complete with 4-pole Aluminium Bus, MCCB, Power contractor, Relay, battery charging system and protections as per OEM specifications. 81 (d) Acoustic enclosure with natural air circulation without loss of any power for ventilation fan. the enclosure shall be modular in contruction with hinge bolted structure to provide easy dismantling and shall be made out of high quality CRCA sheet steel of 1.6 mm thick with sufficient accessories for maintenance work, open able and lockable door with air tight rubber gasket, interior lighting arrangement 1 No LED light fitting of rating as per manufacturer specifications with on/off switch). (e) Fuel tank as per manufacturer recommendation with inlet and outlet connections and fuel level indicator.(f) Base frame made out of suitable MS channel duly reinforced and provided with adequate numbers of anti- vibration pads to ensure minimum vibration as recommendaed by manufacturer. (g) Foundation as per design of manufacturer to be provided bycontractor within overall quoted rates.(h) DG set shall be inspected and tested by rep of CWE before delivery at site. 82 All as per item No 3.43 & 3.44 above, but capacity of DG set shall be 40 KVA with alternator suitable for continuous operation generation 40KVA. 83 PHASE II: Commence after completion of work of Phase I 84 Manning & Operation of following lifts installed at 100 DU’s bldgs in one shift each of 08 Hrs per day including Sunday and holiday, providing rescue to the trapped person, attending day to day maintenance and maintaining the machine/equipments in clean and tidy condition during the operation period.(i) 08 passengers (G+6) – 03 Nos(ii) 13 passengers (G+6) – 03 Nos(iii) 13 passengers (G+4) – 01 NosTradesman to be deployed: One lift operator/technician (skilled) per shift 85 PHASE III: Commence after completion of work of Phase II 86 Manning & Operation of following lifts installed at 100 DU’s bldgs in one shift each of 08 Hrs per day including Sunday and holiday, providing rescue to the trapped person, attending day to day maintenance and maintaining the machine/equipments in clean and tidy condition during the operation period.(i) 08 passengers (G+6) – 03 Nos(ii) 13 passengers (G+6) – 03 Nos(iii) 13 passengers (G+4) – 01 NosTradesman to be deployed: One lift operator/technician (skilled) per shift 87 PHASE IV: Commence after completion of work of Phase III 88 Manning & Operation of following lifts installed at 100 DU’s bldgs in one shift each of 08 Hrs per day including Sunday and holiday, providing rescue to the trapped person, attending day to day maintenance and maintaining the machine/equipments in clean and tidy condition during the operation period.(i) 08 passengers (G+6) – 03 Nos(ii) 13 passengers (G+6) – 03 Nos(iii) 13 passengers (G+4) – 01 NosTradesman to be deployed: One lift operator/technician (skilled) per shift 89 Comprehensive, preventive and periodical maintenance of following electrically operated passenger lifts with electric power operated doors, auto door electric levelling device complete with ARD facility installed at 100 DU’s building to be maintained round the clock as described here-in after in reliable, safe and efficient operating condition by regularly overhauling, servicing & to adjust the mechanical and electrical driving equipment, governor, sleeve shaft assembly bearing/contacts & governor jaws, limit switches (car & hall mechanical buttons, car & hall position indicators, car direction indicators), and all other car and landing signal fixtures, deflectors, car and counter weight guide rails and buffers, equipment and carry out planned maintenance in a systematic and controlled manner using techniques and expertise consultancy; including replacement of spares parts as and when required all as directed and specified to the entire satisfaction of GE.(i) 08 passengers (G+6) – 03 Nos(ii) 13 passengers (G+6) – 03 Nos(iii) 13 passengers (G+4) – 01 NosNote: AMC to be carried out through OEM only. MOU to this effect shall be submitted by the contractor to Engr-in-charge before commencement of work.

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 33.19 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail