| Sl. No. | Item Description |
| 1 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits) completeand making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls withlaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch |
| 3 | All as per item No. 2 above but forOne fan point controlled by one switch/regulator |
| 4 | All as per item No. 2 above but forOne light point controlled by 2 way switch |
| 5 | All as per item No. 2 above but forOne 3 pin socket out let 5 Amps on independent board |
| 6 | All as per item No. 2 above but forOne bell/buzzer point controlled by bell push |
| 7 | All as per item No. 2 above but forOne 3 pin socket out let 5 A on same board |
| 8 | M&L Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiringincl GI/ MS brandedsunken boxes of suitable module concealedon walls including modular frame and cover of suitable modulefixed with cadmium plated iron screws for housing modular typeswitches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch |
| 9 | All as per item No. 8 above but forOne fan point controlled by one switch / regulator |
| 10 | All as per item No. 8 above but forOne light point controlled by 2 way switch |
| 11 | All as per item No. 8 above but forOne 3 pin socket out let 5 Amps on independent board |
| 12 | All as per item No. 8 above but forOne bell/buzzer point controlled by bell push |
| 13 | All as per item No. 8 above but forOne 3 pin socket out let 5 A on same board |
| 14 | All as per item No 2 but concealed wiring drawn through existing PVC conduit.One light point controlled by one switch |
| 15 | All as per item No. 14 above but forOne fan / Exhaust point controlled by one switch / regulator |
| 16 | All as per item No. 14 above but forOne light point controlled by 2 way switch |
| 17 | All as per item No. 14 above but forOne 3 pin socket out let 5 Amps on independent board |
| 18 | All as per item No. 14 above but forOne bell / buzzer point controlled by bell push |
| 19 | All as per item No. 14 above but forOne 3 pin socket out let 5 A on same board |
| 20 | M&L Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI markedincl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 21 | M&L Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductorcable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed. |
| 22 | M&L Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & CapingISI marked incl accessories surface type wiringincl 1.6 mm thick MS sunken boxes concealedon walls includinglaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch |
| 23 | All as per item No. 22 above but forOne fan point controlled by one switch / regulator |
| 24 | All as per item No. 22 above but forOne light point controlled by 2 way switch |
| 25 | All as per item No. 22 above but forOne 3 pin socket out let 5 Amps on independent board |
| 26 | All as per item No. 22 above but forOne bell / buzzer point controlled by bell push |
| 27 | All as per item No. 22 above but forOne 3 pin socket out let 5 A on same board |
| 28 | M&L Point wiringcomplete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI markedincl accessories concealedtype run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 29 | M&L Point wiring completewith 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing capingISI marked incl incl accessories surface type wiring run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 to 29 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be included in unit rate quoted . |
| 30 | S&F in repair LED batten suitable for indoor applications 20 Watts,4 feet with extruded aluminiumhousing & integrated LED channelcomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLAB20 WH LED P or equivalent Makes & model |
| 31 | S&F LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic covercomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLSB 10 WH or equivalent Makes &model of CA |
| 32 | S&F in repair 2\" x 2\" Recess mountedLED Luminaire36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36W GZi WH or equivalent Makes & model of CA |
| 33 | S&F in repair 1\" x 1\" Surface mountedLED Luminaire24 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZSSQL 24W LED WHI or equivalent make & model of CA. |
| 34 | S&F in repair Bulkhead LEDluminaries 10 watt energy efficient solution for upgrading convertional with IP 65 ncluding taking out old fittings as specified and directed. Make: Bajaj, Cat No : BIBWP10WLED or equivalent make & model of CA. |
| 35 | S&F in repairModular switch 1 way 6A,1 module |
| 36 | S&F in repairModular switch 1 way 16A, 1 module |
| 37 | S&F in repair Modular switch 2 way 6A,1 module |
| 38 | S&F in repairx Modular Bell push 6A 1 module |
| 39 | S&F in repair modular Socket, 6A - 2/3 pin combined 2 module |
| 40 | S&F in repair modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 41 | S&F in repair modular type Fan step regulator, 120W - 2 module |
| 42 | S&F in replacement of of Switch piano flush button single pole two way 5 Amps all as specified and as directed. |
| 43 | S&F in replacement of Angle holder PVC / polycarbonate type all as specified and as directed |
| 44 | S&F in replacement of switch piano flush type single pole one way 5 Amps |
| 45 | S&F in replacement of switch socket combination5 pin2 in 1, 5 A Flush typeall as specified and asdirected |
| 46 | S&F in replacement of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and asdirected |
| 47 | S&F in replacement ofsocket outlet 2 in 1, 3 pin 5 A all as specified and asdirected |
| 48 | S&F in replacement of bell push flush type 5A all as specified and asdirected . |
| 49 | S&F in replacement ofMCB SPN 240 volts 32/40 Amps complete all as specified and as directed |
| 50 | S&F in replacement of MCB single pole 240 volts 5-32 Amps complete all as specified and as directed |
| 51 | S&F in replacement ofMCB TPN 415 volts, 10KA \"C\" curve 63 Amps complete all as specified and as directed |
| 52 | S&F in replacement ofMCB TPN 415 volts, 10KA \"C\" curve100 Amps complete all as specified and as directed |
| 53 | S&F in replacement of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbaras specified and as directed. |
| 54 | S&F in replacement of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbaras specified and as directed. |
| 55 | S&F in replacement ofMCB DB TPN 4 way with double door type415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed. |
| 56 | S&F in replacement ofceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 57 | S&F in replacement of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed |
| 58 | S&F in replacement ofDing Dong bellAC 230 volts single pole. |
| 59 | Removing of old unsv wiringand provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 60 | Removing of oldunsv wiringand provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 61 | Removing of oldunsv wiringand provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed.Note for item No. 59 to 61:3 runs of cable and one run of conduit will be measured as unit length. |
| 62 | S&F in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. |
| 63 | S&F in repair LED lamp suitable to fit in angle holder of capacity 09 watt. Make: Bajaj or equivalent in Philips / Havells / CG. |
| 64 | S&F in repair30 WLED bldg securitylight fittingwith pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or equivalent Makes & model of CA. |
| 65 | S&F Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paintover a coat of red oxide primer including removing the old existing GIbracket from bldg complete all as specified and directed. |
| 66 | S&F in repair Storage type water heater 25 Ltrs BEE 5 star ratedcomplete incl steel wired pipe for hot/cold water connection for inlet and out let wateretc completeall as specified and directed at site. Make Bajaj. Model No CALENTA 150801 or equivalent on Venus / Havells) |
| 67 | S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE 3 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directedMake Bajaj, SABSE TEZZ EE 03. Model No 251120 and equivalent on Havells/CG/ USHA. |
| 68 | S&F in repair Exhaust fansAC single phase 230/ 240 V of size 250/280/300 mm sweep with louvers fixed outside withall accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as directed. Make :Bajaj cat No : 70079, MAXX AIR or equivalent in Make Havells/CGs/ Orient |
| 69 | S&F in replacement PVC Fresh air fan of 200mm sweep 1200/1400 RPM with louver. Make CG / Usha / Orient / Phillips / Bajaj. |
| 70 | S&F in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps. |
| 71 | Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately. |
| 72 | S&F in repair stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed. |
| 73 | S&F in repairinternal assembly / apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed. |
| 74 | Supply only heating element of 2 KW rating triangular/round typeas per existing size and type including rubber washers all as specified & as directed. |
| 75 | Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed. |
| 76 | Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size. |
| 77 | Supply only Indicator lamp red and green type square / round. |
| 78 | Supply only Safety valve / high pressure valve / NRV of exisitng type ISI marked. |
| 79 | Supply only PVC insulated Copper cable flexible 3 coreof size 40/0.0076ISI marked. |
| 80 | Supply only outer cover of geyger for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed. |
| 81 | Supply only PVC flexible pipe 16mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed. (Set of 2) |
| 82 | M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying the same one coat of spray paint of white enamel, writing MES No includingtaking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge. |
| 83 | Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed. |
| 84 | Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately. |
| 85 | Supply only ball bearing of various sizes / make as required for ceiling fans / wall mounting / exhaust fan includinggreasing complete all as specified and as directed. |
| 86 | Supply only Gun metal bush of any size / make suitable for ceiling fans all as specified and as directed. |
| 87 | Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust / wall mounting fans complete all as specified and as directed. |
| 88 | Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust / wall mounting fans complete all as specified and as directed. |
| 89 | Supply only PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed. |
| 90 | Supply only Rubber bush with MS bolts, nuts & washers with \"U\" clamps for ceiling fans complete all as specified and as directed. |
| 91 | Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling / re-fixing in its p complete all as specified and as directed. |
| 92 | Dismantling / opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 93 | Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 94 | Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines,preparing the surfaces,filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed. |
| 95 | Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 96 | M&L extension of down rod for ceiling fanupto 1.5 mtr with suitable medium grade GI pipe including nut, bolts , washers complete accessories all as specified and as directed. |
| 97 | Removing the window type AC/Split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, gas charging, adjusting relays etc., replacement of unserviceable spare parts and fixing back atlocation, testing and commissioning complete allas directed. |
| 98 | Removing the split type AC of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace withnew factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position incl testing and commissioning complete all as directedfor the following capacities:-1.5 ton capacity |
| 99 | All as per item No. 98 above but for2.0 ton capacityNote for item No 97 to 99 :- (i)Gas will be measured and paid separately for item No 97 to 99 under relevent item of this schedule.(ii) Spares costing more than 200 Rs will be measured and paid seperately under relevent item of this schedule. |
| 100 | Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities:1.5 Ton |
| 101 | All as per item No. 100 above but forCapacity 2.0 Ton |
| 102 | Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window type AC and water coolers all as specified and directd. |
| 103 | Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for Split/window type AC 1.5/2 ton capacity. (Make- Indfos/Danfoss) |
| 104 | Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete allas directed. |
| 105 | Removing the unservicable running capacitor of 40 MFD, Supply and fix of new capacitorsuitable for 1.5 ton AC.Make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent. |
| 106 | All as per item No 105 herein before, but starting capacitor of 80/100 MFD for 1.5 TR/2 TR AC. |
| 107 | Removing the unservicable over load protection and Supply and fix new over load protector for split/window type AC of 1.5/2.0 TR capacity. |
| 108 | Supply only refrigrent gas (R-22 / 410A / 134A) for domestic coolingappliance. |
| 109 | Disconnecting and taking out the unservicable sensor / remote unit completely and supply and fix new sensor unit of indoor unit of AC to suit the AC of Makes carrier/Bluestar/Voltas1.5 Ton Split type AC |
| 110 | All as per item No. 109 above but forTon Split type AC |
| 111 | Disconnecting and taking out the unservicable PCB, refixing new PCB for split AC / window AC any type and any make 1.5 Ton, 2 Toncapacity all as directed.1.5 Ton Split type AC |
| 112 | All as per item No. 111 above but for Capacity Ton Split type AC |
| 113 | Disconnecting and taking out PCB circuit by disconnecting out PCB from split AC, repairing the same and refixing in original location complete all as specified and directed for 1.5/2 Toncapacity all as directed. |
| 114 | Disconnect electrical connection, removing copper line, discharge line of split type AC upto 2 Ton capacity including indoor and out door units and all accessories and shifting/reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified. |
| 115 | Supply and fix plastic/coir filter suitable for Split/window type AC 1.5/2 Ton capacity including taking down old unsv filter etc complete all as specified and as directed. |
| 116 | Supply and fix voltage stabilizer suitable for Split/window type AC 1.5/2 Ton capacity complete all as specified and as directed. Make : V Guard/Everest/ Sinotech1 KVA |
| 117 | All as per item No. 116 above but for2/3 KVA |
| 118 | All as per item No. 116 above but for5 KVA |
| 119 | S&F in replacement of brass angle valve for gas charging for split AC 1.5/2 ton of AC compete all as specified and as directed. |
| 120 | S&F in replacement of swing motor of existing capacity and type for indoor unit of split AC fins complete all as specified and as directed |
| 121 | S&F in replacement ofMS fabrication clamps for hanging, fan including hook as existing complete all as specified and as directed |
| 122 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TON complete (Against BER) all as specified and as directed. |
| 123 | S&F in replacement ofNitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed. |
| 124 | S&F in replacement of Soft copper tubing 15mm/19 mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed. |
| 125 | S&F in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed. |
| 126 | Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 127 | Excavation in trenches in hard/dense soil not less than 1.5 mtr deep and not exc 3 mtr in deep for pole foundation etc complete all as specified and as directed. |
| 128 | Returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed |
| 129 | Removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 130 | M & L for sand cushioning with a layer of M-Sand sand 23 cm thick under and above the cable complete all as specified and as directed.Note:- Punned thickness will be measured for payment |
| 131 | S & L sub class burnt bricks for cable protection complete as specified as directed |
| 132 | Supply and layingcable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including taking down old unsv / XLPE cable neccessary roadcrossing if applicable for following size :-2 C x 10 Sqmm |
| 133 | All as per item No. 132 above but for4 C x 10 Sqmm |
| 134 | All as per item No. 132 above but for4 C x 16 Sqmm |
| 135 | All as per item No. 132 above but for3.5 C x 25 Sqmm |
| 136 | All as per item No. 132 above but for3.5 C x 35 Sqmm |
| 137 | All as per item No. 132 above but for3.5 C x 50 Sqmm |
| 138 | All as per item No. 132 above but for3.5 C x 70 Sqmm |
| 139 | All as per item No. 132 above but for3.5 C x 95 Sqmm |
| 140 | All as per item No. 132 above but for3.5 C x 120 Sqmm |
| 141 | M&L for replacement ofiron work of any type incl cross arms, supports, bracing MS clamps etc made out of MS channel/angle iron/flat iron/ round section of any size and bolt nuts and washer incl painting with two costs of aluminium paint over a coat of red oxide all as specified and as directed |
| 142 | M&L in replacement of pin type porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 100 mm height and 65mm dia for 1100 volts grade complete all as specified and as directed |
| 143 | M & L in replacement of shackletype porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 75 mm height and 90mm dia for 1100 volts grade complete all as specified and as directed |
| 144 | M & L for GI tubing light grade 40mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 145 | M & L for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 146 | M & L for GI tubing light grade 80mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 147 | M & L in replacement earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed |
| 148 | M & L for tightening of ACSR (Aluminium conductor steel reinforced) conductor of any size between two poles 06 runs of conductor incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed .Note: Length between two poles will be considered as one job. |
| 149 | S & F in replacemet of UNSV existing /suitable size MCCBs 4 pole415 Volts 50HZincl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under:-Make INDOASIAN or equivalent. MCCB 100 Amps ,16 KAwith adjustable Thermal setting |
| 150 | All as per item No. 149 above but forMCCB 200 Amps36 KA withadjustable Thermal setting . |
| 151 | All as per item No. 149 above but forMCCB 250 Amps36 KA withadjustable Thermal setting . |
| 152 | All as per item No. 149 above but forMCCB 315 Amps36 KA withadjustable Thermal setting . |
| 153 | All as per item No. 149 above but forMCCB 63 Amps , 25 KAwith adjustable Thermal setting |
| 154 | M & L for replacement of LT 2 line separator 230 volts 50 Hz all as specified as directed |
| 155 | M & L for replacement of LT 4 line separator 415 volts 50 Hz all as specified as directed |
| 156 | M&L for taking down old cable jointand Supply and fix cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core/4core XLPE armoured aluminium conductor cable for following sizes:-3.5 C x 25 to 35 Sqmm |
| 157 | All as per item No. 156 above but for3.5 C x 50 to 120 Sqmm |
| 158 | M&L for painting of steel tubular/PCC poles of any height and type ,inclsecurity light mounting brackets with one coat of aluminium paint/two coat of cement base paint incluing painting black and yellow strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of pole complete all specified and as directed. |
| 159 | Dismantling of ACSR (Aluminium conductor steel reinforced) conductors |
| 160 | M&L of ACSR (Aluminium conductor steel reinforced) conductor of any size on poles incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed |
| 161 | Refixing of ACSR conductor connected with new existing wire tightening to insulator incl line clearance by pruning of tree branch approx 1 m apart from conductor tightening side. |
| 162 | M&L stay assembley complete with all accessories as shown in elect plate No 1 of SSR Part-I consisting of stay rod 20mm dia 1.8 mtr long,size ofstay plate 230 x 230 x 6 mm with nuts,bolts,insulator stay clamps etc. complete all as shown on drawing and as directed Note:- Excavation and stay wire shall be measured and paid separately |
| 163 | M&L for galvanized stay wire stranded 7/4 mm complete all as specified and as directed |
| 164 | Supply and errect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410SP-31, 9 mtr long including dismantlaing and taking down unsv pole. |
| 165 | M&L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for couping of pole,filling and mass concrete of pole, make good to road surface , hard standing etc incl necessary form work all as specified and as directed |
| 166 | M&L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles all as specified and as directed |
| 167 | M&L for outdoor type, double door sheet metal enclosure/Junction boxof size 80x80x30 cm with aluminiumbus bar 400 Amps for 3 phase & neutralincludingMCCB 4 pole 415 volts 250 Amps 36 KA .including removing old unserviceable junction boxcomplete all as specified and as directed |
| 168 | Supply and fix in replacement of Timeline distribution board 32 A 3 pole /230V analog time switch includingcomplete accessories relay contactor, timeretc,all as specified and as directed. Make:- Indoasian Cat No. TL032AB0 or its equivalent in L&T / SIEMENS |
| 169 | M&L for cable finding cable fault in LT cables any sizes complete all as specified and as directed |
| 170 | Supply & fix in repairs on pole/ wall etc GI pipe bracket made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed. |
| 171 | Supply and fixing,replacement ofmoulded (FRP) junction boxwith IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCBSP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole complete all as directed |
| 172 | Supply and fixing60 WLEDstreetlight fittingwith pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance including taking down old unserviceable street light fittings from pole.Make:- Bajaj, Cat No.:- ENXT P 72 L WH CR PC SD or its equivalent make of CA. |
| 173 | Supply and fixing90 WLEDstreetlight fittingwith pressure die cast housing and toughened glass and individual LEDs withsecondary lens optics with IP 66 ingress protection and impact resistance of IK 07. 5kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance. including taking down old unserviceable street light fittings from pole.Make:- Bajaj, Cat No.:- BRTFG 90W LED CR |
| 174 | Supply & fix in replacement ofon load Change over switch 4 pole in sheet metal enclosure compact design rating 63 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks Make :- INDOASIAN Cat No. ITAS0063 or its equivalent in Havells / L&T / Standard. |
| 175 | Supply & fix in replacement ofon load Change over switch 4 pole in sheet metal enclosure compact design rating 100 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks Make :- INDOASIAN Cat No. ICAS0100 or its equivalent in Havells/L&T/Standard. |
| 176 | Supply & fix in replacement ofon load Change over switch 4 pole in sheet metal enclosure compact design rating 400 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks Make :- Indo Asain / Havells / L&T / Standard. |
| 177 | Dismanling and taking down old unserviceable CFLtype streetlight fittings fromPole, removingthe unserviceable CFLand replacement ofnew LED bulb 40 watt with suitable sizeholderand refixing the existing/new location all asdirected at site. |
| 178 | Dismanling and taking out the LED streetlight fittings any makefromPoleand removingthe burned out /unserviceable LEDdriver25 W to 60Wand replacement ofnew driveto makethe fitting serviceable andrefixing the existing/new location all asdirected at site. |
| 179 | Dismanling and taking out the LED streetlight fittings any makefromPoleand removingthe burned out /unserviceable LEDdriver 90 Wand replacement ofnew driveto makethe fitting serviceable andrefixing the existing/new location all asdirected at site. |
| 180 | Dismanling and taking out the flood lightfrom high mast poleand removingthe burned out/unserviceable LEDdriver 200 Wand replacement ofnew driveto makethe fitting serviceable andrefixing the existing/new location all asdirected at site. |
| 181 | Supply & Fix200W LED flood light luminaries with innovative die-cast aluminium flood light with highly efficient LEDs as light source, suitable for highmast lighting with complete accessories including taking down old unserviceable flood lights from high mast pole all as specified and as directed. Make:- HAVELLS, Code No. : JETAVALOURFL200WLED757PINTNBLTG or its equivalent in Philips / CG / Bajaj |
| 182 | S&F in replacement of new generation 25 Watt post top energy saving IP-65 enviornmental, friendly long life with symmetrically light distribution, spun aluminium with high power LED. Make :- Havells Cat No. CORALPT25WLED757PSYMTOPCor its equivalent in Philips / CG / Bajaj |
| 183 | S&F in replacement of Stellar LED post-top offering combination of sturdy design, execllent illumination and aesthetics in one go. IP 66 and IK 10 rating ensures it stands tall amid varid environemtnal conditionsl, friendly long life with symmetrically light distribution, spun aluminium with high power LED. Make :-Mk -Havells NEBULAPT40WLED857PSYMTOPCor its equivalent in Philips / CG / Bajaj |
| 184 | S&F in replacement of TERRAIN post top lentern is a wether proof indirect lighting solution wich improves horizental uniformity , with reduced glare and improved lighting control saving IP-65 enviornmental , friendly long life with symmetrically light distribution , spun aluminium with high power LED.Make :- Crompton LPTC-40-CDL or equivalent in Phillips / Havells / Bajaj |
| 185 | M&L for painting of outdoor type Feeder piller panel upto the size of 1100 x 450 x 1200 mm (approx), incl replacement of door hinges with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed. |
| 186 | M&L for painting of outdoor type LT panel upto the size of 2500 x 600 x 3000 mm (approx),incl replacement of door hinges with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed. |
| 187 | Boring of holes under road, pavement, hard standing by trenchless techless using ultra sounding technique and necessary machine including HDPEpipe of 63 mm dia bore suitable for 0.4 mpa working pressure. |
| 188 | M&L in replacement of outdoor type LTpanel front opening door upto the size of 2500 x 3000 mm (approx),incl replacement of door hinges with new one and dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of smoke grey colour as directed by Engineer-in-charge complete all specified and as directed. |
| 189 | S&F in replacement of 2 runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of2.5 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length. |
| 190 | Supply, testing and commissioning in replacement ofweather and vermin proof LT feeder pillar boxfactory fabricated outdoor cubical/kiosk type CPRI approved and confirming to IS 5036totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus barforphase & neutral 500 Amps,36 KA capacity and IP 54 protectionmounted on epoxy insulator-01 Set includingmounting the panel board on ground with PCC 1 :3:6 bedding upto a height of 50 cm above ground level and the size of feeder should not less than 150x130x 45 cm. complete all asdirected and comprising the following including taking out unseviceable LT Panel :- Condt/-191 |
| 191 | Condt/-191Note : serviceable MCCB will be deposit at MES store.(i) Incoming MCCB4 pole, 400 Amps 36 KA 415 Volts-01 No(ii)Outgoing MCCB4 pole, 250 Amps 25 KA 415 Volts-01 No(iiI)Outgoing MCCB4 pole, 200 Amps 25 KA 415 Volts-02 Nos(iv) Outgoing MCCB4 pole, 100 Amps 16 KA 415 Volts-02 Nos(iv) Digital Voltmeter 0-500 volts with selector switch - 01 No (v)Digital Amps meter CT operated 0-400 Amps with phase selector switch - 01 Nos(vi)LEDIndicator lamp ( RYB ) - 01 Set (03 Nos) |