Tender For Special Repair Of T32 Troops Shelter At Long Range At Ota Gaya.; 1 Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceedidng 15cm thickness(below ;or aboved ground level) complete all as specified and directed 2 M&L for 75 mm thick Cement concrete type D 2, (1:4:8) (using 40 mm gradedstone aggregate) in sub base of flooring/ hard standing complete all as specified and directed 3 M&L For Machine cut kota stone slab flooring 20-25mm thick over and incl 20mm thickcement screed bed in CM (1:6) laid in floor/skirting and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by engr in charge 4 M &L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed 10mm in CM (1:4) and jointed complete all as specified and directed by engr in charge 5 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed b 6 S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etcFe 410 W (Gde E - 250 quality) complete all as specified and directed 7 Dismantling of asbestos cement corrugated sheets as in roof coverings complete all as specified and directed 8 S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed 9 S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by engr in charge. 10 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed 11 M&L Brick work using sub class old bricks straightor curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed 12 Taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed 13 M & L for rendering 10mm thick internal surfaces on brick work in cm (1:6)in and finishing surfaces even and fair without using extra cement complete all as specified and directed by engr in charge. 14 M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surface and finishing the surface even and smooth without using extra cement secified and directed 15 M&L preparing Old plastered surfaces of wall and applying complete wall with1.0 mm Wallputty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed 16 M&L preparing newly plastered surfaces of wall and applying complete wall with1.0 mm Wallputty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed 17 Preparing Old plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed 18 Preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed 19 M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed 20 M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed 21 Taking down chowkhats or frames not exc 1.5 Sqm ( without taking shutters from the frame) complete all as specified and directed 22 Taking down chowkhats or frames exc 1.5 Sqm ( without taking shutters from the frame) complete all as specified and directed 23 S & F Powder coated aluminium frame/shutters for Door/windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws,etc complete all as specified and directed by engr in charge. Note : (i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item.(ii) Item shall be paid as per weight of aluminium section (iii)The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. 24 M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, framed guard bars; barred iron doors and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed 25 M&L for galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple complete all as specified and directed by engr in charge. 26 S&F 5mm thick tinted glass in aluminium doors & windows with rubber packingincluding hacking out old broken glass ( any thickness, size from aluminium beading ) complete all as specified and directed 27 Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed 28 M&L RCC type B-1, (1:2:4) (using 20 mm graded stone aggregate) in slabs, cantilever or supported on walls and small works like cubes etc complete all as specified and directed 29 M & L for TMTbars 8 mm dia & over cut to length, bent to shape required,including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed 30 Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed . 31 Dismanteling ceiling and wall boards of any type or any thickness inclluding cover fillets complete all as specified and directed 32 S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed 33 S&F 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed 34 Supply & Fixing in repairs Harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers complete all as specified and directed . 35 M&L for Hard core of gauge n exc 63mm thick of broken boulder spread leveling watering ramming to true surface complete all as specified and directed 36 M&L for Cement concrete 1:3:6type C-1 (using 20 mm gradedstone aggregate)75 mm thick as in plinth protections, surface finished even and smooth w/o using extra cement including 3 mm thick glass dividing strip of figured glass , pin headed type, 38 mm wide inserted in position complete all as specified and directed by engr in charge. 37 M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair complete all as specified and directed 38 M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed 39 M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cementcomplete all as specified and directed b 40 Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed at site. 41 Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. 42 Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 43 Taking down ceiling fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard of AGE E/M complete all as specified and as directed. 44 M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25mm ISI marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylum sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincluding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- 45 (a) One light/fan point controlled by one, one way switch 5 Amps 46 (b) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. 47 (c)One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. 48 Description all as per item No. 1 here in before but 3/5 pin socket outlet point 15 amps independant, with cables of size 2.5 sqmm, PVC insulated unsheathed FRLS copper conductor cable and 1.5 sqmm PVC insulated unsheathed FRLS copper conductor cable as earth continuity conductor connected to common earth dolly all in separate PVC concuit medium grade not lesss than 20mm dia ISI marked incl provn of GI sunken box thickness not less than 1.12 mm & 3 mm thick laminated hylem sheet top cover of required size all as specified and directed. 49 S & F modular switch piano flushtype, single pole, one way, and 5/6 Amp single module complete all as specified. 50 S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. 51 S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. 52 S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. 53 S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified 54 S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. 55 S & Fmodular white cover plate with frame 3 module 56 S & Fmodular white cover plate with frame 6/8 module 57 S & Fmodular metal flush box for 3 module 58 S & Fmodular metal flush box for 6/8 module 59 M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 60 S & F for sheet metal enclosure MCBDBTPN4 way Vertical type with 200 Amps suitable for MCCB 125 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 61 Supply and fix 4 Pole MCCB 100 to 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and as directed. 62 S&F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 63 S&F MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and directed. 64 S&F MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and directed. 65 S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete necessary mounting arrangements and provision of 0.75 Sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. 66 Re-fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories complete all as specified and as directed. 67 S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 68 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 69 Supply and laying in replacement of service wire 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured withtape and overall PVC sheathed 50 Sqmm 3.5 core nominal cross section complete all as specified and directed. 70 Galvanised iron steel tubes, ISI marked light grade of size 40mm bore for cable protection along the poles under road under drains complete all as specified. 71 Excavation in trenches n.exc 1.5 mtr wide and 1.5 mtr in depth in hard/dense soil for taking up/ laying of cable and getting out complete all as specified and directed. 72 Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. 73 Removing surplus soil to a distance n.exc 50 mtr and making good the disturbed surfaces complete all as specified and directed. 74 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. 75 Supply and laying for brick of common burnt clay, sub class B old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. 76 Supply and laying for brick of common burnt clay, sub class B old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed.