| 1 | New Electrification Work for Residential Quarters (Qtr. No. 64, 36,34,07, M-3, M-16, M-06 & M-31) and Relocation of Energy Meters to External Locations at V.N.I.T. Campus, Nagpur. |
| 2 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 3 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 14 ways (16 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame as per specification no. SW-MCBDB |
| 4 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB/TP MCB/FP MCB/RCCB/RCBO complete erected on provided angle iron/GI frame |
| 5 | Supplying, erecting, testing & commisioning metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and painted with one coat of red lead paint and 2 coats of enamel paint or powder coating complete as per specification no. CP/SH/CR |
| 6 | Supplying, erecting, testing & commisioning bus bar chamber triple pole with neutral with four copper bars, 500V, 100A having 10mm ( width) x 1.6 mm (thickness), with 99.9 % copper purity as per E91E grade & current density 1.6 A per sq mm compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC insulators and accessories of suitable rating and two nos of separate earthing terminals complete as per specification no. CP-BB |
| 7 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 2 core 10 sq. mm. aluminium conductorcomplete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 8 | Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW |
| 9 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 10 | Wiring for plug on board with Switch socket surface/concealed type, copperwiring and earthing and with modular accessories as per specification No: WG PW/CW |
| 11 | Supplying & erecting HMS PVC conduit 20mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC |
| 12 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20mm with accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 13 | Supplying and erecting PVC trunking (PVC casing-n-capping)of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 14 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 15 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 16 | Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 17 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 18 | Supplying, erecting, testing & commisioning static energy meter with 240V 50 Hz. AC supply 5 to 30 A, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh,V, I, PF, frequency, kW, kVA, six months history of energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weatherproof PVC wires duly tested by electric supply company. (Including Enclosure Box of IP-66 Rating) |
| 19 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 20 | Supplying, erecting & marking DP MCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 21 | Supplying, erecting & marking DP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 22 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 23 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 2 core 6 sq. mm. aluminium conductorcomplete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 24 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 25 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame as per specification no. SW-MCBDB |
| 26 | Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 27 | Supplying, erecting & marking SPMCB 6A to 32A, B-series (for lighting) with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 28 | Supplyinganderectingblankingplate of suitable size on MCB DB. |
| 29 | Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. |
| 30 | Supplying & erecting HMS PVC conduit 32mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC |
| 31 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 60mm with accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 32 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ ceiling as per specification no. WG-MA/CON. |
| 33 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected |
| 34 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected. |
| 35 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. |
| 36 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 37 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. |
| 38 | Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected. |
| 39 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected. |
| 40 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background |
| 41 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 42 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 43 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 44 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 45 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 46 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16/18 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 47 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 48 | Supplying and erecting modular type two way switch 6A/10A (2 module) on provided plate and box with wiring connections complete. |
| 49 | Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete. |
| 50 | Supplying and erecting modular type bell-push with indicator 2 modules 6A/10A on provided plate and box with wiring connections complete |
| 51 | Supplying and erecting ISI mark modular type switch 16 / 20A with indicator, duly erected on provided plate and box withwiring connections complete. |
| 52 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 53 | Supplying and erecting ISI mark modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete. |
| 54 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/ Bus bars or any other places as per specification No: WG-MA/BW |
| 55 | Supplying & erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 56 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 57 | Supplying and erecting crimping type copper lugs for cable upto 16 Sq mm complete as per sepecification No. CB-CL/CU. |
| 58 | Supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, T8 LED tube light (excluding tube light). |
| 59 | Supplying & erecting policarbonate 18W/ 20W, 230V integral type LED fitting 4\" T8 LED tube light batten suitable. |
| 60 | Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. |
| 61 | Supplying and erecting regular/ standard model ceiling fan of 1400mm. Sweep complete erected in position as per specification no. FG-FN/CF |
| 62 | Supplying and erecting exhaust fan modular medium duty 230 V A.C. 50 cycles 225/250 mm. 1400 RPM (for domestic purpose) with condenser complete erected in position with necessary materials . Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 63 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225/250mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 64 | Supplying and erecting modular type (two module) electronic step regulator/dimmer type regulator for fan, duly erected on provided plate and box with wiring connections complete |
| 65 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 66 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit |
| 67 | Supplying & erecting Modular AC box complete with wooden box , MCB, Socket etcsuitable for 2 Ton Air Contioner(A.C) (Make Use Only Havells or Crompton) |
| 68 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 69 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 70 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 /E-27 base. |
| 71 | Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/ SL. |
| 72 | Supplying and erecting street light Wall bracket made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FGBKT/ WB. |
| 73 | Supply, installation, testing, and commissioning of an IP65 surface-mounted heavy-duty PVC enclosure box suitable for single-phase static energy meters, featuring a transparent window, weatherproof, shockproof, and splash-proof design. The unit shall be mounted on a painted iron frame fixed to the wall with proper grouting, complete in all respects. |
| 74 | Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories and filling of holes with POP etc. complete as per specification no. WG-DM/PW |
| 75 | Supplying and erecting crimping type Aluminium lugs for cable upto 16 Sq mm complete. |
| 76 | Supplying and erecting Red, Black, yellow, Blue color PVC Heat Shrinkable Sleeves up to size of single core 25 Sq mm. 1.1 kV insulation capacity which is required on cabejointing area with propwer way as per the Site engineer Instruction |
| 77 | Supplying and erecting Black color PVC Heat Shrinkable Sleeves up to size of 4 core 25 Sq mm. 1.1 kV insulation capacitywhich is required on cabejointing area with propwer way as per the Site engineer Instruction |