|
| 1 | Painting work of bridge and development of park area |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as wellas10sqmonplan)includinggettingoutanddisposalof excavatedearthleadupto50mandliftupto1.5m,asdirectedby Engineer-incharge. All kinds of soil |
| 5 | Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) |
| 8 | Providingandlayingin positionready mixedor sitebatcheddesign mixcementconcreteforreinforcedcementconcretework;using coarseaggregateandfineaggregatederivedfromnaturalsources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retardsettingofconcrete,toimprovedurabilityandworkability withoutimpairingstrength; includingpumping of concrete to site of laying, curing, carriageforallleads; but excluding the cost of centering, shuttering, finishing and reinforcementasperdirectionoftheengineer-in-charge;forthe following grades of concrete.Note:Extracementupto10%oftheminimumspecifiedcement content in design mix shall be payable separately. In case the cement contentindesignmixismorethan1.10timesofthespecified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | Centering and shuttering including strutting, propping etc. And removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Steel reinforcement for R.C.C. work includingstraightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 11 | Providing and fixing M.S. grills of required pattern in frames etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 13 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 14 | 3D Painting on flyover |
| 15 | FinishingwallswithPremiumAcrylicSmoothexteriorpaintwith Silicone additives of required shade: New work (Two or more [email protected]/10sqmover andincludingprimingcoatof exterior primer applied @ 0.90 litre/10 sqm) |
| 16 | Providing and laying factory made cobble shapepaver block 80 mm thick, compressive strength >= M 50 steel mould compressive technolgy. |
| 17 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cementconcrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stoneshall be approved by Engineer-in-charge). |
| 18 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone.Red sand stone |
| 19 | Benches, Size 4x2 feet), Material FRP & GI with Powder Coating |
| 20 | Monkey Sculpture with Illuminated Globe, Size (12x10x10 feet), Material FRP with ISO resin & gelcoat with lighting complete work |
| 21 | Horticulture |
| 22 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-incharge. |
| 23 | Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. |
| 24 | Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same and maintenance for 30 days or more till the grass establish properly, as per direction of the officer in charge |
| 25 | Providing and displaying of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 26 | Electrical Work |
| 27 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed 3core 6 sqmm XLPE cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with theearth conductor by clamps etc.The cable will be connect to existing Electrical Panel.Make-UP PWD Approved |
| 28 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed 3.5 core 35 sqmm XLPE cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with theearth conductor by clamps etc.The cable will be connect to existing Electrical Panel.Make-as per UP PWD Approved |
| 29 | Supply and fixing of 3 Watt to 4 Watt LED Spot/Spike light Confirming to IP 65 and above Protection complete in all respect |
| 30 | Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect. tap.The bidder should be provide the sampleof light for approval.Make-UP PWD Approved CAT-AAA |
| 31 | Supply and fixing of automatic out door type street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch(Timer) TSO 100 series with contactors, HRC fuses/MCB, isolating switch metering instrument & instrument box with CTs with 32A TPN, complete in all respect. Distribution Boards dust proof, vermin proof, with hinged and lockable doors completeinter-connection with copper wire , insulated copper bus bar , cable glands/conduit entry bushes, grounding to earth and painting. Also provide separate neutral busbar for each phase. Provide separate Earth Links for each phase. Use brass thimbles for connections of all wires also provide the provision of out going feeder space for 6nos DP MCB.All Equipments should be as per UP PWD. |
| 32 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve |
| 33 | Supply and fixingof6 Amp. to 32 Amp. DP MCB (10 KA) C Curve |
| 34 | S&F and making connection of 63A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction andsatisfaction to the Engineer in charge. |
| 35 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. |
| 36 | For LT Connection |