}

Tender For The Work Of Reconducting Earthing And Replacement Of Various Feeder Vessel Conductors Emanating From Mahangapur At Various Places In The Area Of ​​Palia Tehsil Under The Business Plan 2025-26 In The Electricity Distribution Section Palia., Kheri-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For The Work Of Reconducting Earthing And Replacement Of Various Feeder Vessel Conductors Emanating From Mahangapur At Various Places In The Area Of ​​Palia Tehsil Under The Business Plan 2025-26 In The Electricity Distribution Section Palia.. Submission Date for this Tender is 18-09-2025. Feeder Pillar Tenders in Kheri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51164507
Tender For The Work Of Reconducting Earthing And Replacement Of Various Feeder Vessel Conductors Emanating From Mahangapur At Various Places In The Area Of ​​Palia Tehsil Under The Business Plan 2025-26 In The Electricity Distribution Section Palia.
Tender
Indian
Uttar Pradesh
Kheri
18-09-2025
BootCamp

Tender Details

For the work of reconducting earthing and replacement of various feeder vessel conductors emanating from Mahangapur at various places in the area of ​​Palia tehsil under the Business Plan 2025-26 in the Electricity Distribution Section Palia. - Work of replacement of 3 KM long 11 KV worn out Weasel Conductor on various feeders emanating from 33/11 KV Substation Mahangapar2 CARRIAGE OF PCC POLE 8.5 MTR LONG(10 NO),A.C.S.R WEASEL CONDUCTOR(7000.00 MTR),11 KV V -TYPE STEEL CROSS ARM 65X65X6 MM(20 NOS),COMPOSITE POLY DISC INSULATOR 70 KN B&S(06 NO),11 KV COMPOSITE POLY PIN INSULATOR (35 NOS) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE3 PROVIDING AND FIXING OF 11 KV F CLAMP(10 NOS) AND ALL ALLIED MATERIAL ARRANGED BY THE CONTRACTOR.4 GROUTING OF 8.5 MTR PCC POLE(10 NO) AND RECONDCUTING OF WEASEL CONDUCTOR AS PER ESTIMATE (AS PER RESPO NORM)5 Reconducting from old hospital to Singhiya6 CARRIAGE OF PCC POLE 8.5 MTR LONG(05 NO),A.C.S.R RABBIT CONDUCTOR(1.790 KM),11 KV V -TYPE STEEL CROSS ARM 65X65X6 MM(05 NOS),COMPOSITE POLY DISC INSULATOR 70 KN B&S(06 NO),11 KV COMPOSITE POLY PIN INSULATOR (15 NOS),G.I. WIRE 4 MM /8 SWG (125 KG),G.I. WIRE 6 SWG( 100 KG),GAURDING ANGLE 50X50X5X2500 MM (10 NO) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE7 PROVIDING AND FIXING OF 11 KV F CLAMP(05 NOS) AND ALL ALLIED MATERIAL ARRANGED BY THE CONTRACTOR.8 GROUTING OF 8.5 MTR PCC POLE(05 NO) AND RECONDCUTING OF RABBIT CONDUCTOR AS PER ESTIMATE (AS PER RESPO NORM)Reconducting from 9 Truck Union to Shri Haridharma Kata10 CARRIAGE OF PCC POLE 8.5 MTR LONG(05 NO),A.C.S.R RABBIT CONDUCTOR(1.380 KM),11 KV V -TYPE STEEL CROSS ARM 65X65X6 MM(05 NOS),11 KV COMPOSITE POLY PIN INSULATOR (15 NOS),G.I. WIRE 4 MM /8 SWG (80 KG),G.I. WIRE 6 SWG( 65 KG),GAURDING ANGLE 50X50X5X2500 MM (05 NO) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE11 PROVIDING AND FIXING OF 11 KV F CLAMP(05 NOS),GAURDING ANGLE CLAMP (05 NO ) AND ALL ALLIED MATERIAL ARRANGED BY THE CONTRACTOR.12 GROUTING OF 8.5 MTR PCC POLE(05 NO) AND RECONDCUTING OF RABBIT CONDUCTOR AS PER ESTIMATE (AS PER RESPO NORM)Reconditioning work from Chini Mile to Hari Dharam Kata on 13 Bheera Road.14 CARRIAGE OF A.C.S.R RABBIT CONDUCTOR(0.750 KM),G.I. WIRE 4 MM /8 SWG (90 KG),G.I. WIRE 6 SWG( 75 KG),GAURDING ANGLE 50X50X5X2500 MM (07 NO) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE15 PROVIDING AND FIXING GAURDING ANGLE CLAMP16 STRINGING OF A.C.S.R RABBIT CONDUCTORAND ALLIED WORKS17 Guarding and re-conducting from railway crossing to fair gate.18 CARRIAGE OF P.C.C POLE 8.5 MTR LONG (02 NO), A.C.S.R RABBIT CONDUCTOR(3.0 KM),G.I. WIRE 4 MM /8 SWG (90 KG),GAURDING ANGLE 50X50X5X2500 MM (11 NO),11 KV PIN COMPOSITE PIN INSULATOR(08 NO) ,G.I. WIRE 6 SWG (70 KG),11 KV V TYPE STEEL CROSS ARM (02 NO),COMPOSITE POLY DISC INSULATOR 70 KN(03 NO) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE19 PROVIDING AND FIXING 11 KV F-CLAMP (02 NO),GAURDING ANGLE CLAMP(11 NO) AND OTHER REQUIRED MATERIAL20 GROUTING OF 8.5 MTR PCC POLE(02 NO),GAURDINGAND RECONDCUTING OF RABBIT CONDUCTOR AS PER ESTIMATE (AS PER RESPO NORM)21 Guarding and re-conducting from old bus stand to Dudhwa intersection.22 CARRIAGE OF P.C.C POLE 8.5 MTR LONG (04 NO), A.C.S.R RABBIT CONDUCTOR(3.60 KM),G.I. WIRE 4 MM /8 SWG (120 KG),GAURDING ANGLE 50X50X5X2500 MM (15 NO),11 KV COMPOSITE PIN INSULATOR(22 NO) ,G.I. WIRE 6 SWG (90 KG),11 KV V TYPE STEEL CROSS ARM (05 NO),COMPOSITE POLY DISC INSULATOR 70 KN(04 NO) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE23 PROVIDING AND FIXING 11 KV F-CLAMP (05 NO),GAURDING ANGLE CLAMP(15 NO) AND OTHER REQUIRED MATERIAL24 GROUTING OF 8.5 MTR PCC POLE(04 NO),GAURDINGAND RECONDCUTING OF RABBIT CONDUCTOR AS PER ESTIMATE (AS PER RESPO NORM)25 Guarding and re-conducting from railway crossing to Tehra crossing.26 CARRIAGE OF P.C.C POLE 8.5 MTR LONG (04 NO), A.C.S.R RABBIT CONDUCTOR(1.95 KM),G.I. WIRE 4 MM /8 SWG (100 KG),GAURDING ANGLE 50X50X5X2500 MM (11 NO),11 KV PIN COMPOSITE PIN INSULATOR(12 NO) ,G.I. WIRE 6 SWG (75 KG),11 KV V TYPE STEEL CROSS ARM (04 NO),COMPOSITE POLY DISC INSULATOR 70 KN(03 NO) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE27 PROVIDING AND FIXING OF11 KV F-CLAMP (04 NO),GAURDING ANGLE CLAMP(11 NO),HOLDING CLAMP FOR PCC POLE (04 NO) AND OTHER REQUIRED MATERIAL28 GROUTING OF 8.5 MTR PCC POLE(04 NO),GAURDINGAND RECONDCUTING OF RABBIT CONDUCTOR AS PER ESTIMATE (AS PER RESPO NORM)29 Guarding and re-conducting from railway crossing to fair gate.30 CARRIAGE OF P.C.C POLE 8.5 MTR LONG (02 NO), A.C.S.R RABBIT CONDUCTOR(3.00 KM),G.I. WIRE 4 MM /8 SWG (100 KG),GAURDING ANGLE 50X50X5X2500 MM (11 NO),11 KV COMPOSITE PIN INSULATOR(08 NO) ,G.I. WIRE 6 SWG (75 KG),11 KV V TYPE STEEL CROSS ARM (04 NO),COMPOSITE POLY DISC INSULATOR 70 KN(05 NO) ANDALL OTHER REQUIRED MATERIAL AS PER ESTIMATE31 PROVIDING AND FIXING OF11 KV F-CLAMP (02 NO),GAURDING ANGLE CLAMP(11 NO),HOLDING CLAMP FOR PCC POLE (04 NO) AND OTHER REQUIREED MATERIAL32 GROUTING OF 8.5 MTR PCC POLE(02 NO),GAURDINGAND RECONDCUTING OF RABBIT CONDUCTOR AS PER ESTIMATE (AS PER RESPO NORM)33 Work of earthing of distribution transformer under sub-station of electricity distribution block Palia, tehsil Palia34 PROVIDING GI PIPE FOR D.T. EARTHING AND OTHER REQUIRED MATERIALS FOR EARTHING( 44 NOS)35 ERRECTION OFGI PIPE FORBoring Type Pipe Eearthing (60ft / Upto Water Level) AND OTHER ALLIED WORKS(FOR 44 NOS)36 GST Extra

Key Value

Document Fees
INR 1180 /-
Tender Value
INR 9.10 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail