Educational and Research Institute Private Organizations Closing in 0 days TDR #51162798

Tender For Supply Installation And Commissioning Of Lab Equipment

Issued by Private Organizations · irinjalakuda, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Oct 2025
0 days left
EMD
18000
Bank guarantee accepted
Document Fee
2700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
irinjalakuda → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Supply Installation And Commissioning Of Lab Equipment-- 1 Electro Chemical Workstation 2 General Techniques • Cyclic Voltammetry (CV) with simulation/fitting programs • Linear Sweep Voltammetry (LSV) with stripping • Bulk Electrolysis with Coulometry (BE) Corrosion • Tafel Plot (TAFEL), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear Polarisation, Corrosion current etc. Fuel cell • Multi-Current Steps (ISTEP) • Polarisation I-V curves Linear Sweep • Open Circuit Potential – Time (OCPT) Impedance • AC Impedance (IMP) (10μHz – 5 MHz) • Impedance – Time (IMPT) (Mott-Scottsky) • Impedance – Potential (IMPE) • Impedance Simulator with fitting • Open Circuit Potential – Time (OCPT) AC Impedance Plots with Simulation • Bode : log Z vs log (freq) • Bode : P{hase , vs log (freq) • Bode : log Z” & Z’ vs log (freq) • Bode : log Y vs log (freq) • Nyquist ; Z” vs Z’ • Admittance; Y” vs Y’ • Warburg: Z” & Z’ vs w1/2 w-angular frequency • Z’ vs w Z” Battery Charge/Discharge • Galvanostatic Charge discharge single/multiple cycle -Chrono Potentiometry (CP) with potentiallimits, polarity by potential or time, no. of cycles etc • Voltage vs current density curves Photovoltaic studies I-V measurements, I max, Pmax, Fill factor etc General Useful Techniques • Chrono Amperometry (CA) • Chrono Coulometry (CC) • Chronopotentiometry with Current Ramp (CPCR) • Potentiometric Stripping Analysis (PSA) • Auxiliary Signal Measurement Channel • RDE control (0-10V output) • IR Compensation • External Potential Input Software requirements: Software package should consist of voltammetry, pulse, battery, super capacitor, Photovoltaic fuel cell, EIS, Equivalent circuit fitting software. • Voltammetry Software- Cyclic Voltammetry, Linear scan Voltammetry, Staircase Voltammetry • Impedance Spectroscopy software- Potentiostatic EIS, Galvanostatic EIS • Pulse software: Differential pulse Voltammetry, Square wave Voltammetry, Stripping voltammetry, Chronoamperometry, Chronopotentiometry & expert • Corrosion: Potentiostatic/Galvanostatic- Gavanodynamic, Tafel, Electrochemical noise • Battery/Super capacitor: charge/discharge Constant potential, GITT, PITT, Constant current, constant power, I-V • 3D plots for graph and Z impedance data • Complete analysis software for CV • EIS circuit fitting facility and software with license • Free Lifetime up gradation of the software.03 Years for electrochemical workstation 03 year for Battery cycler 3 Electro chemical cell 50ml, Teflon cap, purge tube, cell stand 4 Glassy carbon working Electrode 3mm diameter 5 Ag/Agcl Reference Electrode (aq) 6 Ag/Agcl Reference Electrode (non-aq) 7 Platinum wire counter Electrode 50mm 8 Electrode Polishing Kit – 1 No. & Cell Stand 9 Branded Online UPS 1KVA with 60 mins backup 10 Branded Desktop computer i5 Processor, 16GB RAM, 512 GB SSD, 21” Monitor, Windows 11, mouse, keyboard 3 or above years warranty 11 Battery charge – discharge cycler 12 Battery charge – discharge cycler Channel 1 Specifications• Compliance Voltage: ±20 V or higher • Applied voltage: ±14 V or higher • Current ranges: ±5 nA to ±500 mA @ 15V • Minimum applied & measured current resolution: 100pA • Voltage accuracy: 0.1% or better • Current accuracy: 0.1% or better • Impedance frequency range: 10 µHz to 5 MHz • AC amplitude 0.1mV to 5V • Electrode connections: 2, 3 and 4 electrodesChannel 2-9 Specifications• CV Output voltage:25mV-5V • Minimum discharge voltage: -5V • Voltage accuracy: ±0.05%of full scale • Current output: Range:1-5uA-1mA, • Range2:1mA-25mA, Range 3: 25mA-50mA • CV Cut- off current: Range 1:2uA, • Range2 :50uA, Range3 :100uA • Stability: ±0.05% • Response time: ˂500us 13 Communications and power:Branded Desktop computer i5 Processor, 16GB RAM, 512 GB SSD, 21” Monitor, Windows 11, mouse, keyboard 3 or above years warrantyPower supply: 230VAC/50Hz

BOQ

Name of Work: Purchase and commisioning of Lab Equipment
Sl. No. Item Description
1Electro Chemical Workstation
2General Techniques • Cyclic Voltammetry (CV) with simulation/fitting programs • Linear Sweep Voltammetry (LSV) with stripping • Bulk Electrolysis with Coulometry (BE) Corrosion • Tafel Plot (TAFEL), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear Polarisation, Corrosion current etc. Fuel cell • Multi-Current Steps (ISTEP) • Polarisation I-V curves Linear Sweep • Open Circuit Potential – Time (OCPT) Impedance • AC Impedance (IMP) (10μHz – 5 MHz) • Impedance – Time (IMPT) (Mott-Scottsky) • Impedance – Potential (IMPE) • Impedance Simulator with fitting • Open Circuit Potential – Time (OCPT) AC Impedance Plots with Simulation • Bode : log Z vs log (freq) • Bode : P{hase , vs log (freq) • Bode : log Z” & Z’ vs log (freq) • Bode : log Y vs log (freq) • Nyquist ; Z” vs Z’ • Admittance; Y” vs Y’ • Warburg: Z” & Z’ vs w1/2 w-angular frequency • Z’ vs w Z” Battery Charge/Discharge • Galvanostatic Charge discharge single/multiple cycle -Chrono Potentiometry (CP) with potentiallimits, polarity by potential or time, no. of cycles etc • Voltage vs current density curves Photovoltaic studies I-V measurements, I max, Pmax, Fill factor etc General Useful Techniques • Chrono Amperometry (CA) • Chrono Coulometry (CC) • Chronopotentiometry with Current Ramp (CPCR) • Potentiometric Stripping Analysis (PSA) • Auxiliary Signal Measurement Channel • RDE control (0-10V output) • IR Compensation • External Potential Input Software requirements: Software package should consist of voltammetry, pulse, battery, super capacitor, Photovoltaic fuel cell, EIS, Equivalent circuit fitting software. • Voltammetry Software- Cyclic Voltammetry, Linear scan Voltammetry, Staircase Voltammetry • Impedance Spectroscopy software- Potentiostatic EIS, Galvanostatic EIS • Pulse software: Differential pulse Voltammetry, Square wave Voltammetry, Stripping voltammetry, Chronoamperometry, Chronopotentiometry & expert • Corrosion: Potentiostatic/Galvanostatic- Gavanodynamic, Tafel, Electrochemical noise • Battery/Super capacitor: charge/discharge Constant potential, GITT, PITT, Constant current, constant power, I-V • 3D plots for graph and Z impedance data • Complete analysis software for CV • EIS circuit fitting facility and software with license • Free Lifetime up gradation of the software.03 Years for electrochemical workstation 03 year for Battery cycler
3Electro chemical cell 50ml, Teflon cap, purge tube, cell stand
4Glassy carbon working Electrode 3mm diameter
5Ag/Agcl Reference Electrode (aq)
6Ag/Agcl Reference Electrode (non-aq)
7Platinum wire counter Electrode 50mm
8Electrode Polishing Kit – 1 No. & Cell Stand
9Branded Online UPS 1KVA with 60 mins backup
10Branded Desktop computer i5 Processor, 16GB RAM, 512 GB SSD, 21” Monitor, Windows 11, mouse, keyboard 3 or above years warranty
11Battery charge – discharge cycler
12Battery charge – discharge cycler Channel 1 Specifications• Compliance Voltage: ±20 V or higher • Applied voltage: ±14 V or higher • Current ranges: ±5 nA to ±500 mA @ 15V • Minimum applied & measured current resolution: 100pA • Voltage accuracy: 0.1% or better • Current accuracy: 0.1% or better • Impedance frequency range: 10 µHz to 5 MHz • AC amplitude 0.1mV to 5V • Electrode connections: 2, 3 and 4 electrodesChannel 2-9 Specifications• CV Output voltage:25mV-5V • Minimum discharge voltage: -5V • Voltage accuracy: ±0.05%of full scale • Current output: Range:1-5uA-1mA, • Range2:1mA-25mA, Range 3: 25mA-50mA • CV Cut- off current: Range 1:2uA, • Range2 :50uA, Range3 :100uA • Stability: ±0.05% • Response time: ˂500us
13Communications and power:Branded Desktop computer i5 Processor, 16GB RAM, 512 GB SSD, 21” Monitor, Windows 11, mouse, keyboard 3 or above years warrantyPower supply: 230VAC/50Hz

AI Tender Summary

OUR REF NO 51162798
AUTHORITY Private Organizations
TENDER VALUE Ref. Documents
LAST DATE 11-10-2025
Authority
Authority Name St Joseph’s University
Work Description Tender For Supply Installation And Commissioning Of Lab Equipment-- 1 Electro Chemical Workstation 2 General Techniques • Cyclic Voltammetry (CV) with simulation/fitting programs • Linear Sweep Voltammetry (LSV) with stripping • Bulk Electrolysis with Coulometry (BE) Corrosion • Tafel Plot (TAFEL), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear Polarisation, Corrosion current etc. Fuel cell • Multi-Current Steps (ISTEP) • Polarisation I-V curves Linear Sweep • Open Circuit Potential – Time (OCPT) Impedance • AC Impedance (IMP) (10μHz – 5 MHz) • Impedance – Time (IMPT) (Mott-Scottsky) • Impedance – Potential (IMPE) • Impedance Simulator with fitting • Open Circuit Potential – Time (OCPT) AC Impedance Plots with Simulation • Bode : log Z vs log (freq) • Bode : P{hase , vs log (freq) • Bode : log Z” & Z’ vs log (freq) • Bode : log Y vs log (freq) • Nyquist ; Z” vs Z’ • Admittance; Y” vs Y’ • Warburg: Z” & Z’ vs w1/2 w-angular frequency • Z’ vs w Z” Battery Charge/Discharge • Galvanostatic Charge discharge single/multiple cycle -Chrono Potentiometry (CP) with potentiallimits, polarity by potential or time, no. of cycles etc • Voltage vs current density curves Photovoltaic studies I-V measurements, I max, Pmax, Fill factor etc General Useful Techniques • Chrono Amperometry (CA) • Chrono Coulometry (CC) • Chronopotentiometry with Current Ramp (CPCR) • Potentiometric Stripping Analysis (PSA) • Auxiliary Signal Measurement Channel • RDE control (0-10V output) • IR Compensation • External Potential Input Software requirements: Software package should consist of voltammetry, pulse, battery, super capacitor, Photovoltaic fuel cell, EIS, Equivalent circuit fitting software. • Voltammetry Software- Cyclic Voltammetry, Linear scan Voltammetry, Staircase Voltammetry • Impedance Spectroscopy software- Potentiostatic EIS, Galvanostatic EIS • Pulse software: Differential pulse Voltammetry, Square wave Voltammetry, Stripping voltammetry, Chronoamperometry, Chronopotentiometry & expert • Corrosion: Potentiostatic/Galvanostatic- Gavanodynamic, Tafel, Electrochemical noise • Battery/Super capacitor: charge/discharge Constant potential, GITT, PITT, Constant current, constant power, I-V • 3D plots for graph and Z impedance data • Complete analysis software for CV • EIS circuit fitting facility and software with license • Free Lifetime up gradation of the software.03 Years for electrochemical workstation 03 year for Battery cycler 3 Electro chemical cell 50ml, Teflon cap, purge tube, cell stand 4 Glassy carbon working Electrode 3mm diameter 5 Ag/Agcl Reference Electrode (aq) 6 Ag/Agcl Reference Electrode (non-aq) 7 Platinum wire counter Electrode 50mm 8 Electrode Polishing Kit – 1 No. & Cell Stand 9 Branded Online UPS 1KVA with 60 mins backup 10 Branded Desktop computer i5 Processor, 16GB RAM, 512 GB SSD, 21” Monitor, Windows 11, mouse, keyboard 3 or above years warranty 11 Battery charge – discharge cycler 12 Battery charge – discharge cycler Channel 1 Specifications• Compliance Voltage: ±20 V or higher • Applied voltage: ±14 V or higher • Current ranges: ±5 nA to ±500 mA @ 15V • Minimum applied & measured current resolution: 100pA • Voltage accuracy: 0.1% or better • Current accuracy: 0.1% or better • Impedance frequency range: 10 µHz to 5 MHz • AC amplitude 0.1mV to 5V • Electrode connections: 2, 3 and 4 electrodesChannel 2-9 Specifications• CV Output voltage:25mV-5V • Minimum discharge voltage: -5V • Voltage accuracy: ±0.05%of full scale • Current output: Range:1-5uA-1mA, • Range2:1mA-25mA, Range 3: 25mA-50mA • CV Cut- off current: Range 1:2uA, • Range2 :50uA, Range3 :100uA • Stability: ±0.05% • Response time: ˂500us 13 Communications and power:Branded Desktop computer i5 Processor, 16GB RAM, 512 GB SSD, 21” Monitor, Windows 11, mouse, keyboard 3 or above years warrantyPower supply: 230VAC/50Hz
Basic Detail
Tender No A-37/SJC/RUSA/2025
Bidding Type Tender
Location
City irinjalakuda
State Kerala
Key Dates
Publish Date 11 Sep 2025
Submission Date 11 Oct 2025
Open Date 13 Oct 2025
Finance
Tender Value Ref. Documents
Tender Fee 2700
EMD 18000
Exemption Available
Document List
230c0ece-b970-4c48-aac0-6e5a6d41c50c.html
BOQ_1317769.xls
PrelminaryAgreement.pdf
TENDERNOTICE.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 11, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 13, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

230c0ece-b970-4c48-aac0-6e5a6d41c50c.html

xls

BOQ_1317769.xls

pdf

PrelminaryAgreement.pdf

pdf

TENDERNOTICE.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders