Tender For Annual Plan-Pro.No.270/26- Low Mast Light Installation--Edamulackal GP.-Low mast Lt.Installation.-General Electrical Work -- 1 Low mast Installation-Arackal Anganavady South Jn:,Kanjirathara Jn:,Edayam Muthuvanam Jn: and Marur.(7 Mtr) 2 OD222783/2025-2026:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters 3 OD222694/2025-2026:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 7 Meters 4 OD222700/2025-2026:Supply, convey, installation, testing aancend commissioning of 120 Watts single piece LED Flood light fittings suitable for roadway installation with pressure die cast aluminium housing with corrosion resistance powder coating using Nano technology, natural cooling system,, Poly Carbonated UV treated diffuses for higher impact strength and optimum light transmission, High efficient driver with short circuit, over voltage, over current and thermal protection, Surge protection up to 5 K V, PF 0.95, IP 65 protection, Horizontal Pole Mounting type fittings with all connected accessories fixing on the existing arm and giving connections with 1.5 sq. mm 3 core PVC insulated and PVC sheathed copper conductor fles wire etc. as required The LED fittings shall be guaranteed for 3 years from the date of commissioning from any defects in manufacturing. Any of the spares / components which are found to be defective during this period shall be replaced immediately at free of cost. (Make: Philips/ Compton/ Havells )- 120 Watt Flood light 5 14.4:Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. 6 OD222707/2025-2026:Providing and laying in position cement concrete 1:3:6 ( 1cement:3 coarse sand:6 graded stone aggregate 40 mmnominal size) in foundation of Street Light/DG Set./Mini mast Light etc. including form work etc as required. 7 OD222706/2025-2026:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of High Mast/Mini Mast/DG set etc. including form work etc. as required (including reinforcement). 8 90.3.17.3:Supply, conveyance and erection ofthe following sizes of B class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe 9 90.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm 10 90.12.1.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm 11 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size 12 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 13 90.16.3.1:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)20 x 3 mm GI strip 14 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) 15 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 16 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 17 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps 18 OD222720/2025-2026:Supply and providingDIN Rail Programmable Digital timer Switch unit with Relay contactor 230V/25 A/5 Pin with On/Off settings. 19 OD222721/2025-2026:32/63 A fuse holder for BS type blade fuses. 20 OD222722/2025-2026:32/63 A, 230 V, DIN type fuse base. 21 OD222723/2025-2026:32/63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base. 22 OD222725/2025-2026:Suppply and providing pipe earthing as per IS 3043 with 2.6 m long 40 mmdia B class GIpipe,GI funnel with weld mesh,filling required quantity of charcoal&:salt including construction of1:4:8 PCC using 40 mm broken stone(10 cm thick) brick work in mortar1:6,plastering the surface of brick masonary and the exposed surface of PCC bed with cement mortar1:4:12 mm thick(the finished inside dimension shall be 300X300X300. 23 OD222732/2025-2026:Fabrication, supply & installation of dust and vermin proof,wall mounting, Sintex make Code No 3525/Metal Type meter boxsuitable for fixing KSEB meter,fuse units, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 24 OD222729/2025-2026:Preparation of all drawing submitting and approvel from KSEB, obtaining power allocation, submitting of completion certificates and arranginginspection, getting sanction and energisation certificates from KSEB and obtaining power connection (single phase connection) etc: for commissioning of the whole installation in the permises.