Different Type Of Electrical Work Against Business Plan 2025-26 Under Jurisdiction Of E.E., Edd, Dubagga, Amousi Zone, Lesa. - Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj /any near byMVVNL Store to Work Site 3 33 KV VCB 800 Amp. 4 33 KV VCB 1250 AMP 5 33 KV Control Pannel double Transformer 6 33 KV Control pannel single Feeder 7 33 KV Lightening Arrester 400 Amp/30 KV 8 33 KVLine Isolator 9 33 KVBus Isolator 10 33KVCurrent Transformer 200/100/1 11 33KVCurrent Transformer 400/200/1 12 11 KV Incoming VCB 600/300/5A 13 11 KV Out going VCB 200/100/5A 14 11 KV VCB Bus coupler 15 Battery set 12 Nos. x 2 Volts , 200 Ah 16 Battery Charger 24 Volt 17 33 KV PT Outdoor (33 KV/110V) 18 ACSR Panther Conductor for Bus Bar 19 Disc Insulator B/S 70 KN 20 Disc Fitting 70 KN 21 11 KV 3x300mm2 XLPE Cable 22 11 KV3x185mm2 XLPE Cable 23 11 KV 3x70mm2 XLPE cablesub station feeder 24 11 KV3x300mm2Outdoor Termination Kit 25 11 KV3x300mm2Indoor Termination Kit 26 11 KV3x185mm2Outdoor Termination Kit 27 11 KV3x185mm2Indoor Termination Kit 28 11 KV 3x70mm2 Termination Kit outdoor 29 11 KV 3x70mm2 Termination Kit indoor 30 Cost of 11/0.4 KVTransformer 63 KVA 31 LT Armourd cable 3.5x70 mm2 32 LT XLPE cable 400 sqmm for 5 MVA lead 33 ST pole 11 mtr long 34 ST pole 9 mtr long 35 M.S.channel 100x50 sq mm 36 M.S.Angle 65x65x6 sq mm 37 Polymeric 11KV Pin Insulator 38 MS Earthing Rod 20x2500 mm 39 11 kv pin with nut 40 1x240 LT XLPE Cable 41 Top channel 100x50mm 42 Rail 105 lb 9 mtr long 8no. 43 MS Channel 125x65mm 3.5m long 4 Nos Pieces 14M@13.1 Kg. Mtr. With wastage 44 MS Angle 75x75x6, 2.6M 2 Nos Total 5.2@6.8 Kg./M with wastage 45 MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge 550m@6.21 Kg./M 46 MS Round of 32mm dia for making MS earth electrode 32x3000mm. 78No.x3.0M@6.21 Kg./M 47 Earthing of substation Switchyard. 48 Checking of soil resistivity of S/S land and if required take necessary measure to make soil resistivity as per norms. 49 MS Round Bar 32 mm dia (6.21 Kg. per mtr.) for laying of main earth matin switchyard &pannel earthing Bridge 160 ckt. Mtr. 50 MS Round Bar 32 mm dia (6.21 Kg. per mtr.) for making M.S. Earth electrod 32x3000 mm (14no.x3.0mtr.) 51 Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete (10mtr.x15mtr.) as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all material ) 52 Cutting ,fabrication and driving of earth electrode of size 32x3000 mm 53 Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor ) 54 Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms. 55 Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel). 56 Painting of all structures & equipment. 57 Painting offeeder name on D/P & Cable stand as per site engineer a 58 Erection of 33 KV Bus Bar Gantary complete with structure. (All materials will provide by contractor except Rail pole). 59 Stringing, sagging, jumpering of bus bar gantrywith ACSR panther conductor 3Phase 3wire. 60 Construction of Power T/F plinth suitable for 33/11KV 5 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 Mas 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8using M.S bar of 12 mm dia for reinforcementthe work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department) 61 Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB. 62 Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt) 63 Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structureas per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect. 64 Erection of structures, grouting, plinthing of ALL structuresequipment. 65 Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment . 66 33 KV VCB 67 CT 200/100/1-A 68 CT 400/200/1-A 69 33 KV PT Outdoor (33 KV/110V) 70 33 KV lightning Arrestors 71 Bus/Line Isolator 72 Fabrication & Erection of Neutral Stand structure with foundation 73 Commissining and Testing of5 MVA T/F & Control cable laying & Termisnation by using cable gland & Lugs 74 Jumpering complete T/F bay with ACSR panther Cond. and required L clamp with nut & Bolts from 33 KV existing bus bar & 33 KV cable to T/F (with copper L piece)other all required work. ( Except Panther Conductor all required material provided by Contractor.) 75 Jumpering complete 33 KV Line bay with ACSR panther Cond. and required clamp with nut & Bolts from Incoming 33KV Feeder to Bus bar gantry.(01 no complete 33 KV bay) 76 Laying of double circuit 11 KV 3x300 sq mm XLPE cable in normal soil by digging of suitable size of trench as per site condition cable should be covered by bricks and sand. 77 Laying of double circuit 11 KV 3x300 sq mm XLPE cable in Existing trech. 78 Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand, panelwith proper taping with the help of empire tape. PVC tape and connectors. 79 Hoisting of 11KV3X185 sqmm XLPE cable on double pole with MS pipe/GI pipe of size 5/6 dia 3 M longincluding its jumpering complete with clamps, nuts and bolts(all material arranged by contractor). 80 Laying of Single circuit 11 KV 3x185 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench. 81 Hoisting, jumpering, clamping of 11KV 3x185 sq mm & 3x70 sqmm XLPE cable on 11 KV panelswith proper taping with the help of empire tape. PVC tape and connectors. 82 Laying of Double circuit 11 KV 3x70 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench. 83 Hoisting of 11KV3X70 sqmm XLPE cable on double pole with MS pipe/GI pipe of size 4/6 dia 3 M longincluding its jumpering complete with clamps, nuts and bolts(all material arranged by contractor). 84 Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench. 85 Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms 86 Supply & Laying of Armoured copper control cable of following sizes its proper dressing ,ferruling and connection with the system. 87 Armoured Copper Control Cable 2x2.5 Sq. mm. 88 ArmouredCopper Control Cable 4x2.5 Sq. mm. 89 Provding & Fixing of Cable Tray with cover for supportof copper control cable (CT, PT ,VC B & T/F etc.) (All materials will be Provided by contractorexpact thesupplieditem ) as per respo norms 90 Pipe boring type earthing minimum 30 mtr deepfrom ground level or upto water level with B class G.I. pipe 1.5 dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor) 91 Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms 92 33 KV Double T/F Control panel 93 33 KV Single feeder Control panel 94 11 KV Incoming VCB 600/300/5A 95 11 KV Out going VCB 200/100/5A 96 11 KV VCB Bus coupler, 350 MVA 97 Erection ofS/S Type Double Pole for 63 KV S/S T/F 98 Laying of double circuit 11KV 3x70 sq mm XLPE cable in cable trench with proper ferrurling. Cable trench should filled by fine sand. 99 Laying of LT cable of size 3.5x70 sq mm in between station T/F and distribution switch in the room and its proper lugging, connecting and tapping etc. 100 Supply and fixing LT distribution panel for lighning of control room,switch yard and substation building the panel contaaining 1 no 63 amp MCCB and 5 no Outgoing MCBs for substaion buliding, yard lighting,AC and DC supply of panels etc. 101 Fabrication, erection, grouting, plinthing and painting of ST pole 9 M long as RESPO norms and mounting of LEDlamp 120 watt complete work . (All material except Pole ,shall be provided by the contracter) 102 Fire Fighting equipments including 02 Nos. 4.5 Kg. Co2 Fire Extinguisher potable type and 02 Nos. Foam type Fire Extinguisher potable type 103 Cost of Misc. Items i.e. Rubber Matting 04 nos.Single Line Diagram Board, Tripping Chart Board, S/S Board 104 Erection of 24 V (2 Volt x12 No.) batteries set with charger(200 VA) including stand (stand shall be provided by contractor) & initial charging complete set. 105 PG Clamp Panther to Panther 106 Grouting,Plinthing and Painting of new erected 11M long ST poles ofdouble pole cableexposures 107 Digging of Pit in kachcha/Pakka land in depth upto 1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 11 KV line on 11 M long ST Pole and refilling with ramming of earth. 108 Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms. 109 Construction of pole plinth 300mm x 450 mm above ground levelin 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms. 110 Painting of new erected ST pole with two coat of red oxide paint,PO red paint at top of pole 2 M& balance by twocoats ofbest quality aluminium paint ISI of Burger/Nerolac/Asian mark as pernorms. 111 Earthing of11 mtr, 9 mtr ST pole with MS earthing rod 20Х2500 mm 112 Fabrication & erection of 11 KV D/C cable exposure type double pole with the provission ofcable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire,2 no. channels 100x50mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size Al.lug after making three phase busbar with help of 11 KV pin,pin insulator and PVC cable. (all material arranged by contractor except steel,pole & insulator).as per RESPO norms. 113 Sand filling in cable trench under control roomwith fine sand after laying of 11 KV cables (Fine sand should be provided by the contracter) 114 Construction of Toe wall around the outdoor Switchyard of the S/Sof size 0.75x0.25 Mt.At Base and 0.25 Mt. At top as per RESSPO Normsby lst class bricks in the ratio 1:6, Base concreting of the wall to be done in ratio1:6:12 and plaster 12 mm thick in ratio 1:4.& Switch Yard fencing with wire mesh Fencing3 Mlong 2.5 mtr height & Toe walleach Pannel (all material arranged by contractor ) 115 Fabrication of switchyard fencingwith wiremesh10 SWG (37mmx50mm) as per drawing along with Fabrication of one number gate made of MS Angle, MS Channel, MS Flat together with locking arrangement, its Installation including the cost of civil material, angle 50x50x6mm, Channel Etc . (all material arranged by contractor ) 116 Interlinking Tileswide complete work including material and labour with Providing grovel in (20 mm stone ballast) in Swithchyard area. 117 Complete work of fixing of inertlocking tils in swithchyard area. (All the materials shall be provided by contracter) 118 Providing gravels (20 mm stone ballast) in swithcyard upto 15 cmhight form the graund level. 119 Provide Fire BucketSet (one set contains one no. stand and four no. bucket) 120 Construction of RCC cable trench 800x850mm as per drawing including trench Cover in Angle fram. Size of angle 75x75x6 mm trench wallthikness 1500mm grill by MS rod10 mm dia vartical distance 6 Horizateldistance4 121 High pressure testing 122 Substation Furniture (4–Chairs, 1–Table, 1–Bench, 1–Rack, 1–Stool) 123 Making of Plinth and 11 KV stand suitable for 63 KVA T/F 124 Installation of 63 KVA T/F onT/F plinth / double pole and comissingincludingjumpering with the system( All materialshall be pro vided by thecontractor except thesupplieditem) as per Resspo Norms 125 Survey and electrical layout of 33/11 KV Sub-station 126 Lighting of Outdoor switch yard and approach road. 127 Return backbalance material from site toLESA store daliganj . 128 33 KV Line 129 Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj /any near byMVVNL Store to Work Site 130 ACSR DOG CONDUCTOR 131 33KV3X300 SQ MM XLPE CABLE 132 33 KV ST/TH C/J KIT 3X300 SQ MM 133 33KVEND TERMINATION OUT DOOR 3X300 SQ MM 134 PCCPole 8.5 Mt Long 135 ST Pole 11 Mt Long 136 V type channel Cross Arm (100x50mm) 137 Polymeric 33KV Pin Insulator 138 33KV Pin with Nut 139 M S Earthing Rod 20x2500 mm 140 Polymeric 11KV Disc insulator 70 KN(B&S type) 141 Disc fitting for Polymeric 11KV Disc insulator45 KN (B&S type) 142 Topchanel 125X65MM 143 Stay rod 20x1800mm Completewith Grouting 144 Stay Wire 7/8 SWG 145 M.S. chanel 100X50MM 146 M.S. Angle Iron 65x65x6mm Bracing. 2 no. 4300 mm 147 LT XLPE Cable AL.1X400 Sq.mm. 148 Stay Set 20x1800mm Completed 149 GI wire 6 Swg 150 Fabrication & erection of single pole for 33 KV line on 11 M long STPole with fixing of necessary clamp & other acessories like 1 no. Channel cross arm, Danger board, No Plate, barbed wire etc.contractor shall provide, necessary clamps, F-Bracket etc. as per RESPO norms. 151 Fabrication & erection of single pole for 33 KV line on 8.5 M long PCC Pole with fixing of necessary clamp & other acessories like 1 no. Channel cross arm, Danger board, No Plate, barbed wire etc.contractor shall provide, necessary clamps, F-Bracket etc. as per RESPO norms. 152 Fabrication & erection of 33 KV cable exposure type double pole with the provission of separate bus bar for each cable withfixingofnecesoryclampsandotheracessorieslike danger board,number plate,barbed wire, 9 no. pin insulators with pins,2 no. channels 125x65mm (1600mm each),1 no.MS channel 125x65mm(3200mm in length) and 2 no.MS angle 65x65x6 mm (each 3200mm in length ) for supportingthehoistingofcable&poles.itsjumperingby singlecorePVCaluminiumcablewithpropersizeoflug. (allmaterialarrangedbycontractorexceptsteel,pole,PVC aluminium cable & insulator).as per RESPO norms. 153 EndTypeDoublePole-Fabrication,erection,ofdouble pole of end terminations with one side cable exposure for 33KV line on 11M long ST pole with fixing of necessary clamps&otheraccessorieslikediscinsulator,1no.top chennel 125×65 mm - 3.20M & 1 no. gaurding angle and 1 no.Xbracing,discfittingits,33kvpinwithpininsulator,dangerboard,numberplate,barbedwire,jumperingbyPG clamp 4no stay complete work(all material arranged by contractor except steel,insulator,disc insulator with fitting & pole).as per RESPO norms. 154 SectionalDoublePole-Fabrication,erection,ofdouble polefor33KVlineon11MlongSTpolewithfixingof necessary clamps & other accessories like ,disc insulator, 1 no.topchennel125×65mm-3.20M&1no.gaurding angle andX bracing,disc fittingits,33kv pin with pin insulator,dangerboard,numberplate,barbed wire,jumpering by PG clamp 8 no Stay set etc.(all material arranged by contractor exceptsteel,insulator,discinsulator GI Pin, Disc Fitting & pole).as per RESPO norms. 155 Fabrication, erection, of Fourpole for 33 KV line on 11 M longSTpolewithfixingofnecessaryclamps&other accessorieslike,discinsulator, 4 no. topchennel 125×65 mm-3.20M&gaurdingangleand X bracing,discfittingits,33kvpinwithpininsulator,danger board,number plate,barbed wire,jumpering by PGclamp 8 no stay setetc.(all material arranged by contractor except steel,insulator,discinsulator GI Pin,Disc Fitting& pole).asper RESPO norms. 156 Erection of single stud pole support one ST pole 11 M long withfixingofnecessaryclampsandotheraccessories required for erection. 157 Makingpropermarkigofcablebymarkigtape/marking tagat properinterval(every 2mtrunderneath) marking tape/tag provided by contractor 158 Laying of 33 KV XLPE cable 159 Laying of 33 kV 3x300 sq. mm XLPE cable D/C including digging of trench 1050 mm deep, 750 mm wide along with required material Sand (0.195 Cub/Mtr), Ist class bricks (26.25 Nos/Mtr), stone pad (2.2 Nos size 600x750x50 mm). The inter axial spacing between two cable should be in between 0.32 M to 0.40 M. (As per JE instruction) and back filling the trench by soil (All the material required for laying will be supplied by the contractor except 33 kV XLPE cable) 160 Cable layingBy drill methodS/C 161 Cable layingBy dirll methodSingle circuit with MS/ GI/HDPE Pipe 160 mm dia 162 Digging of Pit in kachcha/Pakka land in 1.2 mtr deep 3 mtr long and 2mtr wide for 33KV ST/TH3x300sqmm and boxing with brick sand and stone slab as per norms. 163 Hoisting of 33KV XLPE cable on double pole with GI pipe of size 5/6 dia 3 M longincluding its jumpering complete with clamps, nuts and bolts(all material arranged by contractor). 164 Making cable stand & its Grouting, earthing & Hoisting of 33 KV Cable on cable stand 165 Fixing of cable marker and dipitching of feeder name and voltage on this 166 Route Survey & profiling of 33KV line from 132 KV s/s Jehta to proposed 33 /11 KV s/s FCI New ( Length 9.2km) 167 Plotting of cable layout rute on graph paper (i.e. depth underneath and distance from either side from prominent reference fixed point ) the reference point must not be more than 10 mtr. 168 Stringing&Saggingofthreephase33kvlineonACSRdog conductor as per RESPO Norms. 169 Stringing and sagging of three nos. Earth/GI wire with caddle guarding of above 33 kv line as per RESPO Norms. 170 Guarding of O/H Line (50 Mtr span)- Fabrication and fixing of gaurding angle on single/double Polesras per RESSPO Normsincluding provision of all necessary clamps and hooks. 171 Ordinary Earthing of pole by M.S. Earthing Rod 20x2500 mm as per Resspo Norms only earting rod provided by deptt 172 Extra Stay Set - Nozzillling & grouting of stay set .(all the material except stay set will be arranged by the contractor) 173 Grouting,Plinting and Painting of new erected 11M long ST poles of single pole support,double pole cableexposures and end type poles of 33 KV lines 174 DiggingofPitinkachcha/Pakkalandindepthupto1/6 length of Pole, Dragging of STPfrom near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 33 KV line on 11 M long ST Pole and refilling with ramming of earth. 175 Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms. 176 Construction of pole plinth 300mm x 450 mm above ground levelin 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms. 177 Painting of new erected ST pole with two coat of red oxide paint,POredpaintattopofpole2M &balancebytwo coatsof bestqualityaluminiumpaintISIof Burger/Nerolac/Asian mark as pernorms. 178 Supply and fixing of cable route marker of 33 KV 179 High Pressure Testing and fault location of 33 cables/line/ as per norms 180 Tree branches cutting and lopping chopping where required 181 SCANING/ TRACINGOFEXISTING UNDERNEATH POWER CABLES, WATER PIPE LINE , GAS PIPE LINE , SEWERPIPELINE ONPROPOSEDROUTE TO AV OID POSSIBLITES OF ANY KIND OF DAMAGEDURING DIGGING OF TRENCH/DRILLING FOR LAYING CABLE. (SCANNINGMA CHINE WILL BEPROVIDED BYTHE CONTRACTOR) 182 Return backbalance material from site toLESA store daliganj . 183 11 KV LINE 184 Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area. 185 11 KV 3x185 sq mm XLPE cable 186 11 KV 3x185 sq mm O/D 187 11 KV 3x185 sqmm St/Th 188 ACSR Weasel Conductor 189 8.5 Mtr PCC Pole 190 M.S.channel 100x50 sq mm 191 M.S. Angle Iron 65x65x6mm Bracing. 2 no. 4300 mm 192 Polymeric11KV pininsulator 193 11 kv pin with nut 194 M S Earthing Rod 20x2500 mm 195 1x240 LT XLPE Cable 196 Polymeric11 kv Disc insulator T&C 45 KN 197 Stay wire 7/10 SWG 198 Disc fitting T&C Type 45 KN 199 Stay Set 16x1800 Complete 200 11 KV V type steel cross arm angle 65x65x6mm 201 GI wire 8 Swg 202 Fabrication & erection of single pole Supportfor 11 KV line on 8.5 M long PCC Pole with fixing of necessary clamp & other acessories like 1 no. Channel cross arm, Danger board, barbed wire etc.contractor shall provide, necessary clamps, F-Bracket etc. as per RESPO norms. 203 Fabrication & erection of 11 KV cable exposure type double poleon 8.5 M long PCC Polewith the provission of separate bus bar for each cable withfixingofnecesoryclampsandotheracessorieslike danger board,number plate,barbed wire, 9 no. pin insulators with pins,2 no. channels 125x65mm (1600mm each),1 no.MS channel 125x65mm(3200mm in length) and 2 no.MS angle 65x65x6 mm (each 3200mm in length ) for supportingthehoistingofcable&poles.itsjumperingby singlecorePVCaluminiumcablewithpropersizeoflug. (allmaterialarrangedbycontractorexceptsteel,pole,PVC aluminium cable & insulator).as per RESPO norms. 204 EndTypeDoublePole-Fabrication,erection,ofdouble pole of end terminations with one side cable exposure for 11KV line onon 8.5 M long PCC Polewith fixing of necessary clamps&otheraccessorieslikediscinsulator,1no.top chennel 125×65 mm - 3.20M & 1 no. gaurding angle and 1 no.Xbracing,discfittingits, 11kvpinwithpininsulator,dangerboard,numberplate,barbedwire,jumperingbyPG clamp 4no stay complete work(all material arranged by contractor except steel,insulator,disc insulator with fitting & pole).as per RESPO norms. 205 Laying of 11 KV XLPE cable 206 Laying of Double circuit 11 KV 3x185 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench. 207 Cable layingBy dirll methodSingle circuit with MS/ GI Pipe 6 dia 208 Cable laying by drill method S/C in HDPE Pipe 4Dia 209 Cable laying by drillHDD method S/C 210 Digging of Pit in kachcha/Pakka land in 1.2 mtr deep 3 mtr long and 2mtr wide for 33KV ST/TH3x300sqmm and boxing with brick sand and stone slab as per norms. 211 Hoisting of 11 KV XLPE cable on double pole with GI pipe of size 4 dia 3 M longincluding its jumpering complete with clamps, nuts and bolts(all material arranged by contractor). 212 Stringing&Saggingofthreephase11kvlineonACSR weasel conductor as per RESPO Norms. 213 Stringing and sagging of three nos. Earth/GI wire withh caddle guarding of above 11 kv line as per RESPO Norms. Shifting of existing line conductor of 11 Kv/LT lines to maintain proper clearence in between both lines. 214 Guarding of O/H Line (50 Mtr span)- Fabrication and fixing of gaurding angle on single/double Polesras per RESSPO Normsincluding provision of all necessary clamps and hooks.Shifting of existing line conductor of 11 KV/LT lines to maintain proper clearence in between both Lines.(all the material arranged by contractor except steel and GI wire 6swg) 215 Ordinary Earthing of pole by M.S. Earthing Rod 20x2500mm as per Resspo Norms only earting rod provided by deptt 216 Extra Stay Set - Nozzillling & grouting of stay set .(all the material except stay set will be arranged by the contractor) 217 Route Survey & profiling of 11 KV line from Newlyproposed 33 /11 KV s/s FCI New to Vairous 11 KV Feeder 218 Plotting of cable layout rute on graph paper (i.e. depth underneath and distance from either side from prominent reference fixed point ) the reference point must not be more than 10 mtr. 219 Grouting & Plinting and Painting of new erected 11M long ST poles of single pole support,double pole cableexposures and end type poles of 11 KV lines 220 DiggingofPitinkachcha/Pakkalandindepthupto1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 11 KV line on 11 M long ST Pole and refilling with ramming of earth. 221 Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms. 222 Construction of pole plinth 300mm x 450 mm above ground levelin 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms. 223 High Pressure Testing and fault location of 11 KV cables/line/ as per norms 224 SCANING/ TRACINGOFEXISTING UNDERNEATH POWER CABLES, WATER PIPE LINE , GAS PIPE LINE , SEWERPIPELINE ONPROPOSEDROUTE TO AV OID POSSIBLITES OF ANY KIND OF DAMAGEDURING DIGGING OF TRENCH/DRILLING FOR LAYING CABLE. (SCANNINGMA CHINE WILL BEPROVIDED BYTHE CONTRACTOR) 225 Return backbalance material from site to LESA store daliganj . 226 GST Extra as per Rules