Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kind of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge.All kinds of soil |
| 3 | Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns |
| 8 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. Non-pigmented wet curring compound |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 18 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand). With Modular bricks |
| 19 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement :4 coarse sand) |
| 20 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 21 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 22 | Repair of various 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, with welding of all damaged corners, MS sheet, joints and repalcement of damaged hinges & all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 23 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 24 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 25 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 26 | Providing and fixing bolts including nuts and washers complete. |
| 27 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 28 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 29 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 30 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 31 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 32 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 33 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 34 | Neat cement punning. |
| 35 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 36 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre |
| 37 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 38 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 39 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 40 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in-charge .The elevationalarea of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 41 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 42 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm. |
| 43 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independentstaging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall becleaned of silt and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. |
| 44 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 45 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 46 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 47 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 48 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal ofunserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar |
| 49 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 50 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 51 | Providing and laying 60mm thick faciory made cement concreteinterlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved size, design& shape, laid in required colour and pattern over and including 50mmthick compacted bed of coarse sand, filling the joints with line sandetc. all complete as per the direction of Engineer-in-charge. |
| 52 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. |
| 53 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 54 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe |
| 55 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 56 | Extra for depth for manholes : Size 90x80 cm. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 57 | Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. |
| 58 | Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg. |
| 59 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter |
| 60 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5 |
| 61 | Septic tank cleaning by using athourized sewer suction trucks of capacity of 300.00 litre as approved by civil muncipal coorpuration authority and disposal of all sewer, sludge, malda, rubish, etc to the area as also specified by Civil muncipal Coorpuration. |
| 62 | Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. |
| 63 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer in-charge. |
| 64 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 65 | Servicing & overhauling existing HP Raw Sewage pump sets including replacement of defenctive spare parts like bearing, seal, empeller, suction & discharge valve, pipe & fitting rewinding of motor, etc all complete as required (1 year waranty of pump sets). |
| 66 | Servicing & overhauling existing 15HP air blower \"Everest make\" including supplying and fixing of V-belt, safety valve, belt gaurd, pressure gauge of 4\" dial with valve, tee and fitting, replacement of damaged & defenctive spare parts like bearing, seal, etc all complete as required (1 year waranty of air blower). |
| 67 | Servicing & overhauling of existing HP filter feed pump including replacement of damaged & defenctive spare parts like bearing, seal, empeller, suction & discharge vauve, pipe & fitting rewinding of motor, etc all complete as required (1 year waranty of filter feed pump). |
| 68 | Servicing & overhauling of treated HP water pumps including replacement of damaged & defective spare parts like bearing, seal, empuller, suction & discharge valve, pipe & fittings rewinding , etc all complete as required (1 year waranty of treated water pump sets) |
| 69 | Providing and filling MBBR/FMR/FAB Media virgin PP to support the growth of bio-mass in Aeration tanks including removing & disposing the existing media approx. 8 Cum or more etc all complete as required. |
| 70 | Servicing & overhauling of HP sluge pump & centrifuge/filter press including replacement of filter cloth, tap & handle and all defective & damaged spare parts etc all complete as required. |
| 71 | SITC (Supply, Installation, Testing &Commissioning) of air diffusers of various sizes, for providing clog-free oxigen, consisting of the fine bubble EPDM membrance diffusers, SS-316 clips, UPVC pipe of 10 kg/Sqcm pressure rating, UPVC fitting, nylon rope braided hose with all accessories to make it retrievable etc. complete as required in to Aeration Tank, sludge holding tank and equalization tank after dismantling existing diffusers etc as required. |
| 72 | Servicing and re-commissioning of activated Grade Filter including providing and replacing the complete 800 Kg carbon after empling and cleaning the tank etc all complete as required. |
| 73 | Servicing & re-commissioning of Multi Grade Filter including providing and replacing the complete 1000 Kg multigrade sand after emplting and cleaning the tank etc all complete as required. |
| 74 | Continuty and insulation testing of all wiring/cabling supply including replacement of faulty cables, identification ferules, end terminations, jointing providing and fixing of channels & supports etc all complete as required. |
| 75 | Supply & Installation of electro-magnetic, online flowmeters for input & output, size 2\", flow: 0.2 to 30 Cum/Hour etc all complete as required. |
| 76 | Supply & installation of chlorine dosing system including 1 No\"s chemical dosing pump make:- Edose/Milton roy & 1 No\"s PVC chemical preparation tank, capacity 100 litre, etc all complete as required. |
| 77 | Servicing and overhauling of exisiting OZON generator machine etc all complete as required. |
| 78 | Supply & fixing, repair & replacement of various size & shape uPVC/CPVC 2\", SHD-40 pipe, all types of pipes & all fittings to lift all existing arrangement/system of all type of supply lines & fittings up-to 20\" feet above the exisitng ground & floor surface, repair & replacement of all damaged & defective parts of existing supply lines wherever required i/c painting, etc all complete as required by Engineering-in-charge. |
| 79 | Service charge including re-commissioning of the 300 KLD STP plant, additional of bacterial culture, jagri, DAP, Urea liquid Chlorine, etc all complete for initial commissioning of the said STP complete as required by Engineering-in-charge. |
| 80 | Fabrication, installation, testing and commisioning of cubical outdoor type compartmentalized dust and virmin proof suitable to replace exsiting damaged electrical panel of 300 KLD STP for 415 V 3 phase, 50 Hz supply having hinged gasketted and lockable centre opening double door fabricated from 2mm thick MS sheet with 35x35x5 mm angle base frame & leg of 75x75x5mmof 75 cmt long front openable complete with interconnection with copper wire, painting, earthing the body & suitable size CC work padestal with plastering i/c providing and fixing of following accessories in it etc as required, with relay, contractors, starters, sequential pump controllers, Aluminium bus-bars, designation labels as per requerement, continous earth bar, panel separators, protective screens, cablle clamping support system, bottom cable gland plates for incoming and outgoing cable entries, etc as required complete by engineer-in-charge. (Face area shall not be less than 2.00 SQM and depth 0.40 Mtr.). MCC Panel for 300 KLD STP |
| 81 | Servicing & overhauling existing 1/1.5 HP Raw Sewage pump sets including replacement of defenctive spare parts like bearing, seal, empeller, suction & discharge valve, pipe & fitting rewinding of motor, etc all complete as required (1 year waranty of pump sets). |
| 82 | Servicing & overhauling existing 2HP air blower \"ABB make\" including supplying and fixing of V-belt, safety valve, belt gaurd, pressure gauge of 4\" dial with valve, tee and fitting, replacement of damaged & defenctive spare parts like bearing, seal, etc all complete as required (1 year waranty of air blower). |
| 83 | Servicing & overhauling of existing 1/1.5HP filter feed pump including replacement of damaged & defenctive spare parts like bearing, seal, empeller, suction & discharge vauve, pipe & fitting rewinding of motor, etc all complete as required (1 year waranty of pump set). |
| 84 | Servicing & overhauling of 1/1.5HP treated water pumps including replacement of damaged & defective spare parts like bearing, seal, empuller, suction & discharge valve, pipe & fittings rewinding , etc all complete as required (1 year waranty of pump sets) |
| 85 | Providing and filling MBBR/FMR/FAB Media virgin PP to support the growth of bio-mass in Aeration tanks including removing & disposing the existing media, etc all complete as required by Engineering-in-charge (approx. 5 Cum or more per 25 KLD STP) |
| 86 | Servicing & overhauling of 3HP sluge pump & centrifuge/filter press including replacement of filter cloth, tap & handle and all defective & damaged spare parts etc all complete as required (1 year waranty of pump sets). |
| 87 | SITC (Supply, Installation, Testing &Commissioning) of air diffusers of varing sizes, for providing clog-free oxigen, consisting of the fine bubble EPDM membrance diffusers, SS-316 clips, UPVC pipe, UPVC fitting, nylon rope braided hose with all accessories to make it retrievable etc. complete as required in to Aeration Tank, sludge holding tank and equalization tank after dismantling existing diffusers etc all complete as required by engineering-in-charge. |
| 88 | Servicing and re-commissioning of activated Grade Filter including providing and replacing the complete after empling and cleaning the tank etc all complete as required by Engineering-in-charge. |
| 89 | Servicing & re-commissioning of Multi Grade Filter including providing and replacing complete the existing multigrade sand after emplting and cleaning the tank etc all complete as required. |
| 90 | Continuty and insulation testing of all wiring/cabling supply including replacement of faulty cables, identification ferules, end terminations, jointing providing and fixing of channels & supports etc all complete as required. |
| 91 | Supply & Installation of electro-magnetic, online flowmeters for input & output, size 2\", flow: 0.2 to 20 Cum/Hour etc all complete as required. |
| 92 | Supply & installation of chlorine dosing system including 1 No\"s chemical dosing pump make:- Edose/Milton roy & 1 No\"s PVC chemical preparation tank, of required capacity, etc all complete as required. |
| 93 | Servicing and overhauling of exisiting OZON generator machine etc all complete as required. |
| 94 | Supply & fixing, repair & replacement of various size & shape uPVC/CPVC 2\", SHD-40 pipe, all types of pipes & all fittings to lift all existing arrangement/system of all type of supply lines & fittings to 2\" feet above the exisitng ground & floor surface, repair & replacement of all damaged & defective parts of existing supply lines wherever required i/c painting, etc all complete as required by Engineering-in-charge. |
| 95 | Service charge including re-commissioning of the 25 KLD STP plant, additional of bacterial culture, jagri, DAP, Urea liquid Chlorine, etc all complete for initial commissioning of the said STP complete as required by Engineering-in-charge. |
| 96 | Fabrication, installation, testing and commisioning of cubical outdoor type compartmentalized dust and virmin proof suitable to replace exsiting damaged electrical panel of a 25 KLD capacity STP for 415 V 3 phase, 50 Hz supply having hinged gasketted and lockable centre opening double door fabricated from 2mm thick MS sheet with 35x35x5 mm angle base frame & leg of 75x75x5mmof 75 cmt long front openable complete with interconnection with copper wire, painting, earthing the body & suitable size CC work padestal with plastering i/c providing and fixing of following accessories in it etc as required, with relay, contractors, starters, sequential pump controllers, Aluminium bus-bars, designation labels as per requerement, continous earth bar, panel separators, protective screens, cablle clamping support system, bottom cable gland plates for incoming and outgoing cable entries, etc as required complete by engineer-in-charge. (Face area shall not be less than 1.20 SQM and depth 0.40 Mtr.). MCC Panel for 25/30 KLD STP |
| 97 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 98 | Supplying,installation,testing and commissioning of energy efficientT8 LED batten luminaries with 20 watt LED lamp separately,made of aluminium die cast housing complete with electronic driver and all other accessories suitable for operation on 230v,50 Hz supply etc complete as required. |
| 99 | Supplying, installation of 300 mm sweep 900 RPM heavy duty exhaust fan with metallouver shutter of suitable size in the existing opening suitable for 230 V 50 Hz AC supply connection, testing, commissioning etc. as reqd. |
| 100 | Supplying and making streght through Joint with Cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor cable of 1.1 KV grade as required. 4 X 16 Sq.mm (4 Core) |
| 101 | Supplying and making streght through Joint with Cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor cable of 1.1 KV grade as required. 3.5 X 70 Sq.mm (3.5 Core) |
| 102 | Supplying and laying of following size XPLE insulated, armoured, power cable of 1.1 KV grade, duly ISI marked, with Aluminium conductor, confirming to IS: 7098 (Part-I) in existing RCC / HUME / GI / DWC HDPE pipe, as required. 4 X 16 Sq.mm (4 core) |
| 103 | Supplying and laying of following size XPLE insulated, armoured, power cable of 1.1 KV grade, duly ISI marked, with Aluminium conductor, confirming to IS: 7098 (Part-I) in existing RCC / HUME / GI / DWC HDPE pipe, as required. 2 X 25 Sqmm ( 2 core) |
| 104 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as reqd. 3.5 X 70 Sq.mm (38mm) |
| 105 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as reqd. 4 X 16 Sq.mm (28mm) |
| 106 | Rewiring of existing light point/fan point/exhuast fan point/call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable and 1.5 Sqmm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit i/c dismantling and buyback of old etc complete as required. Group B |
| 107 | Supplying and drawing flollowing sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit including dismantaling and buyback of old etc as required. 1X1.5 Sqmm |
| 108 | Supplying and drawing flollowing sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit including dismantaling and buyback of old etc as required. 2X2.5 Sqmm |
| 109 | Supplying and drawing flollowing sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit including dismantaling and buyback of old etc as required. 3X2.5 Sqmm |
| 110 | Supplying and drawing flollowing sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit including dismantaling and buyback of old etc as required. 2 X 4 Sqmm |
| 111 | Supplying and drawing flollowing sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit including dismantaling and buyback of old etc as required. 3 X 4 Sqmm |
| 112 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 113 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125 mm X 75 mm) (Make: Red-Bond) |
| 114 | Supplying an fixing following modular base & cover plate on existing modular metal boxes etc as required. 8 Module (Make: Red-Bond) |
| 115 | Supplying an fixing following modular base & cover plate on existing modular metal boxes etc as required. 6 Module (Make: Red-Bond) |
| 116 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 117 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 118 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 119 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 120 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 121 | Providing preventive and comprehensive maintenance of 2X25 KLD capacity STP (Sewage treatment plant) including lubricant and replacement of damaged electrical & mechanical spare parts, fiteration media and materials complete as required. |
| 122 | Providing, running & operation of 2 X 25 KLD capacity STP (Sewage treatment plant) on all working days i/c Sunday and holiday complete as required by deputing 2 No\"s skilled operator for round to clock operation as required. |
| 123 | Supplying and charging of following consumable / chemicals for day to day requireme nt in the existing 2 No\"s X 25 KLD STP plant. Sodium Hypo (Liquid Chlorine) with 12% conc. |
| 124 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Bacterial Culture |
| 125 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Urea Fertilizer |
| 126 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. DAP Fertilizer |
| 127 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Gur/Sheera |
| 128 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Bleaching Powder |
| 129 | Providing test report of treated water of STP from NABL/PCB approved testing Lab including collection of sample water, transportation, sampling etc. test report satisfactory on treated water parameter as per required. |
| 130 | Providing preventive and comprehensive maintenance of 300 KLD capacity STP (Sewage treatment plant) including lubricant and replacement of damaged electrical & mechanical spare parts, fiteration media and materials complete as required. |
| 131 | Providing, running & operation of 2 X 25 KLD capacity STP (Sewage treatment plant) on all working days i/c Sunday and holiday complete as required by deputing 3 No\"s skilled operato for round to clock operation as required. |
| 132 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Sodium Hypo (Liquid Chlorine) with 12% conc. |
| 133 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Bacterial Culture |
| 134 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Urea Fertilizer |
| 135 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. DAP Fertilizer |
| 136 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Gur/Sheera |
| 137 | Supplying and charging of following consumable / chemicals for day to day requirement in the existing 2 No\"s X 25 KLD STP plant. Bleaching Powder |
| 138 | Providing test report of treated water of STP from NABL/PCB approved testing Lab including collection of sample water, transportation, sampling etc. test report satisfactory on treated water parameter as per required. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy